首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到4条相似文献,搜索用时 78 毫秒
1.
2.
BACKGROUND AND PURPOSE: Sacral insufficiency fractures are an infrequent but often disabling cause of severe low back pain. We report our results of a sacroplasty technique, using CT for needle placement and fluoroscopy to monitor the polymethylmethacrylate injection in a group of patients with sacral insufficiency fractures. METHODS: All patients had a history of chronic back pain and had an osteoporotic sacral insufficiency fracture documented by imaging before the procedure. With the patient under conscious sedation, a bone biopsy needle was placed under CT guidance; the patient was then transferred to the fluoroscopy suite, where a polymethylmethacrylate mixture was injected into the sacrum under real-time fluoroscopy. Clinical outcome was assessed by telephone. RESULTS: The procedure was performed on 13 female patients with an average age of 76 years (range, 60-88 years). A bilateral procedure was performed in 11 patients and a unilateral procedure was performed in 2 patients. An average of 4.1 mL of cement was injected for each treatment. There were no instances of cement extravasation into the central canal or sacral foramina. Long-term follow-up, averaging 15 months, was available in 6 patients. Five patients (83%) reported no symptoms of pain at all. The final patient, in whom a bilateral procedure was performed, was completely asymptomatic on the left side but reported persistent unilateral pain on the right. CONCLUSION: Sacroplasty is a safe and effective procedure in the treatment of sacral insufficiency fractures that can provide substantial pain relief and lead to a better quality of life.  相似文献   

3.
4.
PurposeTo assess whether the use of needle guidance devices can reduce fluoroscopy time and operator hand dose during cone-beam computed tomography–guided needle interventions.Materials and MethodsThe freehand technique was compared with techniques employing two distinct needle holders and a ceiling-mounted laser guidance technique. Laser guidance was used either alone or in combination with needle holders. Four interventional radiologists were instructed to reach predetermined targets in an abdominal phantom using these techniques. Each operator used all six techniques three times. Fluoroscopy time, procedure time, operator hand dose, and needle tip deviation were obtained for all simulated needle interventions. All data are presented as median (ranges).ResultsAll procedures were successfully completed within 2–4 minutes, resulting in a deviation from target of 0.8 mm (0–4.7). In freehand procedures, the fluoroscopy time to reach the target was 50 seconds (31–98 s). Laser guidance, used alone or in combination with needle holders, reduced fluoroscopy time to 31 seconds (14–68 s) (P<.02). The operator hand dose in freehand procedures was 275 μSv (20–603 μSv). Laser guidance alone or in combination with needle holders resulted in a reduction of the hand dose to<36 μSv (5–82 μSv) per procedure (P<.001). There were no statistically significant effects on hand dose levels or fluoroscopy time when the needle holders were employed alone.ConclusionsCompared with the freehand technique, all three tested needle guidance devices performed with equivalent efficiency in terms of accuracy and procedure time. Only the addition of laser guidance was found to reduce both fluoroscopy time and operator hand dose.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号