首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 218 毫秒
1.
单克隆抗体Dot-ELISA检测血吸虫病循环抗原的研究.Ⅰ.   总被引:1,自引:0,他引:1  
将血吸虫肠相关阴极抗原的单克隆抗体3D8A联结过氧化物酶后用于直接法Dot-ELISA检测急性、慢性与晚期血吸虫病人血清中循环抗原,阳性率分别为90.6、83.2及30.7%。正常人血清及非寄生虫感染病人血清均未见阳性反应。EPG>100组血清阳性率及抗原水平高于EPG<100。慢性血吸虫病人经吡喹酮治疗后一年,粪检阴性者大部分血清抗原转为阴性;粪检阳性者血清检查仍为阳性。结果表明,肠相关阴极抗原单克隆抗体3D8A能用于Dot-ELISA检测各期病人血清中循环抗原,并能反映病人感染度与药物治疗效果。  相似文献   

2.
单克隆抗体Dot-ELISA检测血吸虫病循环抗原的研究Ⅱ   总被引:6,自引:1,他引:5  
将血吸虫肠相关阳极抗原单克隆抗体1B10A标记过氧化物酶后用于Dot-ELISA检测了急、慢性血吸虫病人血清中循环抗原,阳性率分别为90%、80.8%,除肺吸虫外,对其他主要的寄生虫病感染、非寄生虫感染性疾病及正常人无阳性反应。检测EPG>80病人血清中的抗原水平高于EPG<80者;病人经有效药物治疗后,粪检阳性者,大部分抗原检测转为阴性,其余抗原滴度呈不同程度下降。将该单克隆抗体与肠相关阴极抗原的单克隆抗体,分别检测同批血清,结果基本一致。将肠相关阳极抗原与阴极抗原的单克隆抗体联合应用,能增强某些弱反应。  相似文献   

3.
用杂交瘤技术生产抗血吸虫肠相关循环阳极抗原单克隆抗体与血吸虫卵糖蛋白单克隆抗体经混合后标记辣根过氧化物酶,制成Dot-ELISA诊断试剂盒,检测轻、中、重不同疫区粪检阳性的血吸虫闰人血清中循环抗原,阳性率分别为84.3%、87.2%和91.5%。  相似文献   

4.
金标渗滤法快速检测血吸虫循环抗原的现场应用研究   总被引:6,自引:1,他引:5  
将抗重组蛋白SVLBP-IgG用于DIGFA检测2221例血清中血吸虫循环抗原,其中急性血吸虫病人血清70份,慢性血吸虫病人血清307份,循环抗原检出率分别为100%和68.4%。非流行区健康人血清200份,未见阳性反应。除肺吸虫外,与其它寄生虫或非寄生虫感染病人血清无明显交叉反应。用DIGFA单盲法检测2批血清,结果显示对急性血吸虫病人的敏感性均为100%;对慢性血吸虫病人的敏感性分别为69.4  相似文献   

5.
应用抗马来丝虫成虫单克隆抗体结合免疫放射测定法,对马来丝虫成早抗原,马来丝虫成虫排泄-分泌抗原,马来微丝蚴抗原及班氏丝虫病病人血清中循环抗原进行了检测。马来丝虫成虫抗原检出的最低含量为0.48pg,ES抗原,马来微丝蚴抗原可测得抗原结合量分别为0.35μg和0.065μg,班氏丝虫病人血清中循环抗原的检测结果阳性率为80%,线虫病流行区50份微丝蚴阴性血清及丝虫病非流行区50份肠道蠕虫感染者血清全  相似文献   

6.
单克隆抗体技术的发展为检测血吸虫循环抗原提供了特异的探针工具,展示了良好的应用前景。我们用杂交瘤技术制备了2株抗日本血吸虫肠相关循环阳极抗原(CAA)的单抗和1株抗虫卵糖蛋白的单抗。经混合后标记HRP,制成Dot-ELISA诊断试剂盒,经检测轻、中、重不同疫区粪检阳性的血吸虫病人血清694份,循环抗原阳性率分别为84.3%(86/102)、87.2%(177/203)和91.5%(365/389)。对照Kato-Katz粪便虫卵计数结果,EPG>80的病人组检  相似文献   

7.
应用抗马来丝虫成虫单克隆抗体(McAb)结合免疫放射测定法(IRMA),对马来丝虫成虫抗原、马来丝虫成虫排泄-分泌抗原(ES抗原)、马来微丝蚴抗原及班氏丝虫病病人血清中循环抗原进行了检测。马来丝虫成虫抗原检出的最低含量为0.48pg,ES抗原、马来微丝蚴抗原可测得抗原结合量分别为0.35μg和0.065μg,班氏丝虫病人血清中循环抗原的检测结果阳性率为80%(40/50),丝虫病流行区50份微丝蚴阴性血清及丝虫病非流行区50份肠道蠕虫感染者血清全部为阴性。  相似文献   

8.
本文用抗日本血吸虫肠相关抗原的单克隆抗体Sj116和Sj10c作双夹心ELISA检测粪检阳性的血吸虫病人血清中的循环抗原,阳性率达93.4%。正常人假阳性率为6.7%。与肺吸虫、华支睾吸虫、旋毛虫及囊虫病的交叉反应分另伪3.2%、0、13.3%和13.3%。  相似文献   

9.
本文用抗日本血吸虫肠相关抗原的单克隆抗体Sj116和Sj10c作双夹心ELISA检测粪检阳性的血吸虫病人血清中的循环抗原,阳性率达93.4%。正常人假阳性率为6.7%。与肺吸虫、华支睾吸虫、旋毛虫及囊虫病的交叉反应分别为3.2%、0、13.3%和13.3%。  相似文献   

10.
本研究以囊液10000g上清、囊液100000g上清、全囊抗原、头节抗原和头节尿素溶解性抗原等5种囊尾蚴抗原,对124份各类血清进行斑点-ELISA试验,结果除2种囊液抗原外,都有很高的假阳性反应。2种囊液抗原中以100000g离心者为优,检测70例囊虫病患者,阳性率为82.8%;30例正常人,假阳性率为6.7%;5例血吸虫、5例华支睾吸虫及5例并殖吸虫患者血清,均未出现阳性反应;但9例包虫病患者血清均出现交叉反应。  相似文献   

11.
A monoclonal antibody (designated 8SE) against membrane antigen of adult Schistosoma japonicum labeled with HRP was used in dot-ELISA (direct method) to detect schistosomal circulating membrane antigen. Sera from 48 parasitologically confirmed schistosomiasis cases were tested, 39 (81.3%) were positive. No false positive reaction was found in sera from 24 healthy controls. No cross reaction was detected in sera from clonorchiasis or paragonimiasis in 18 cases each. This results suggest that circulating membrane antigen does exist in patients with schistosomiasis and it might be used as a complementary method for diagnosis of schistosomiasis. A preliminary result of idiotype/antiidiotype interaction inhibition reaction for detecting circulating membrane antigen was also presented.  相似文献   

12.
将血吸虫成虫表膜机原的单克隆抗体8SE4联接辣根过氧化物酶制成结合物,用于直接法斑点-ELISA检测循环抗原。结果48例血吸虫病患者的阳性率为81.3%(39例),24例正常人未出现假阳性反应。检测华支睾吸虫及并殖吸虫病患者各18例,均无交叉反应。本结果证实日本血吸虫病患者血清中有循环表膜抗原存在。直接法斑点-ELISA方法简便,具有较高的敏感性和特异性,可作为诊断日本血吸虫病的补充方法。本文还报告了独特型/抗独特型(8SE_4/抗8SE_4)抑制试验检测循环表膜抗原的初步结果。  相似文献   

13.
A double antibody enzyme-linked immunosorbent assay (sandwich ELISA) was used for the detection of a circulating antigen from human schistosomiasis japonica infections. This assay involves the use of polyclonal rabbit Schistosoma japonicum soluble egg antigen (SEA) antiserum to bind circulating antigen and a monoclonal antibody (MabH4) to identify and quantify this antigen. Sera from 108 S. japonicum-infected patients (acute and chronic) were tested. Sera from 93 of 95 patients with chronic infection were positive for this antigen; sera from 12 of 13 patients with acute infections were also positive. Antigen was not detectable in control human sera. Sera from 35 chronic schistosomiasis patients were collected 6-12 months after praziquantel treatment. Circulating antigen was not detectable in the sera of 33 of these patients and was dramatically reduced in 2. This ELISA system may prove valuable in differentiating past and current infections.  相似文献   

14.
Sera from patients with chronic schistosomiasis (Schistosoma mansoni or Schistosoma haematobium) were examined for the presence of parasite specific IgE antibodies by means of ELISA technique using tegument antigen prepared from adult worms of Schistosoma mansoni and using the monoclonal antibody BL-IgE 9. Individuals from tropical countries who had no schistosomiasis and blood donors from GDR were studied for comparison. Significantly higher levels of specific IgE antibody were given by sera from patients with schistosomiasis than by the controls. These differential responses serologically differentiated between patients with chronic schistosome infections and noninfected individuals.  相似文献   

15.
血吸虫循环抗原检测的现场试验Ⅱ   总被引:1,自引:1,他引:1  
制备血吸虫病单克隆抗体诊断试剂盒,将其用于Dot—ELISA,分别检测江苏、安徽流行区急性血吸虫病患者及四川、江西、安徽流行区慢性血吸虫病患者血清中循环抗原。结果不同流行区Dot—ELISA反应的平均“+”值、阳性率和抗原滴度的几何均数不同,循环抗原水平可以反映流行区的疫情。另将Dot—ELISA、ELISA检测四川慢性血吸虫病人治前及治后半年、1年的血清循环抗原及抗体,结果循环抗原在病人治疗后很快下降,治后1年77.8%(35/45)病人的循环抗原转为阴性。循环抗体在病人治疗后也逐渐下降,但速度甚为缓慢。治疗后1年,仅21.7%(10/46)病人转为阴性。上述结果表明,循环抗原能更直接、更真实地反映防治效果。  相似文献   

16.
目的 进一步探讨抗重组血吸虫磷酸丙糖异构酶(rSjCTPI)的单克隆抗体检测血吸虫循环抗原对血吸虫病疗效考核的价值。方法 建立以纯化的抗日本血吸虫可溶性虫卵抗原(SEA)的多克隆抗体(IgG)为捕捉系统,以酶标抗rSjCTPI为检测系统的酶联免疫吸附试验(P-M-ELISA)法,分别对同批治疗前及治疗后2、4、6、12个月的血吸虫病人进行检测,并与常规检测抗体的SEA-ELISA法比较。结果 P-M-ELISA法对治疗前血吸虫病人检测阳性率为96.6%,而检测抗体的SEA-ELISA为98.3%,P-M-ELISA法对治愈后2、4、6、12个月血清循环抗原检测阴转率分别为15.3%、37.3%、52.0%、83.3%,而检测抗体的SEA-ELISA法分别为3.4%、6.8%、12.0%、16.7%。结论 表明该法既有较好的诊断价值,又有较好的疗效考核价值。  相似文献   

17.
[目的 ]检测血吸虫病患者的循环抗原。 [方法 ]用多抗与单抗夹心 EL ISA法检测日本血吸虫病患者血清循环抗原。 [结果 ]用于检测 15 0例血吸虫病患者的循环抗原 ,其敏感性平均为 84.7% (72 .0 %~ 91.0 % ) ,40例正常人未出现假阳性反应 ,74例其他寄生虫感染者中 ,有 2例并殖吸虫病患者阳性 ,其余均未出现交叉反应。 [结论 ]多抗与单抗夹心 EL ISA法是一种较为理想的循环抗原检测方法。  相似文献   

18.
将血吸虫肠相关趋阴极抗原的单克隆抗体用于Dot—ELISA,共检测2175份血清,其中急性血吸虫病血清210份,阳性率为91.9%;慢性血吸虫病血清798份,阳性率为86.7%;正常人血清752份,假阳性率为1.1%;除肺吸虫病外,对其他寄生虫病或非寄生虫感染疾病血清无明显交叉反应。用单盲法Dot—ELISA检测3批血清,结果敏感性为86.5%~95.1%;特异性为96.9%~100.0%。检测流行区居民547份血清,Dot—ELISA阳性反应130份;粪检阳性72例。两者均为阳性者55例,相符率为76.4%。上述结果表明,Dot—ELISA检测循环抗原确实具有较好的敏感性与特异性,适于大规模应用及流行病学调查。  相似文献   

19.
本研究用双抗夹心ELISA法检测慢性日本血吸虫病人血清循环抗原,观察血吸虫感染家兔血清循环抗原的动态变化。该方法采用兔抗AWA-IgG作包被抗体,抗日本血吸虫成虫和虫卵单抗SJA111和74D11组合作Ⅱ抗,172例经粪孵毛蚴确诊的血吸虫病人中,136例循环抗原阳性(79.1%),其中轻度(毛蚴数<5只/20克粪)、中度(6-20)、重度(大于20)感染者循环抗原阳性率分别为73.4%、87.7%、92.8%,检测65例健康献血员,20例肺吸虫病人,12例华支睾吸虫病人,10倒包虫病人,交叉反应率依次为1.5%、5%、0%、0%,42例经吡喹酮治疗后的血吸虫病人用该方法复查,治后3月和6月随访粪孵毛蚴阴转者中,循环抗原阴转率分别为78.0%和92.1%,考核疗效明显优于检测循环抗体。用单抗SJA111检测感染家兔循环抗原动态变化,循环抗原于感染后3—4周可检出,7周达高峰,以后逐渐消退,而循环抗体(IgG)推迟1周出现,8-9周达高峰。实验结果表明,血吸虫病血清CAg阳性率与感染度有关,可在早期检出,检测方法具有较高敏感性和特异性,可用于早期诊断和疗效考核。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号