首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
PURPOSE: To prospectively compare the image quality, sensitivity, and specificity of three-dimensional gadolinium-enhanced magnetic resonance (MR) angiography accelerated by parallel acquisition (ie, fast MR angiography) with MR angiography not accelerated by parallel acquisition (ie, conventional MR angiography) for assessment of aortoiliac and renal arteries, with digital subtraction angiography (DSA) as the reference standard. MATERIALS AND METHODS: The study was approved by the institutional review board; informed consent was obtained from all patients. Forty consecutive patients (33 men, seven women; mean age, 63 years) suspected of having aortoiliac and renal arterial stenoses and thus examined with DSA underwent both fast (mean imaging time, 17 seconds) and conventional (mean imaging time, 29 seconds) MR angiography. The arterial tree was divided into segments for image analysis. Two readers independently evaluated all MR angiograms for image quality, presence of arterial stenosis, and renal arterial variants. Image quality, sensitivity, and specificity were analyzed on per-patient and per-segment bases for multiple comparisons (with Bonferroni correction) and for dependencies between segments (with patient as the primary sample unit). Interobserver agreement was evaluated by using kappa statistics. RESULTS: Overall, the image quality with fast MR angiography was significantly better (P=.001) than that with conventional MR angiography. At per-segment analysis, the image quality of fast MR angiograms of the distal renal artery tended to be better than that of conventional MR angiograms of these vessels. Differences in sensitivity for the detection of arterial stenosis between the two MR angiography techniques were not significant for either reader. Interobserver agreement in the detection of variant renal artery anatomy was excellent with both conventional and fast MR angiography (kappa=1.00). CONCLUSION: Fast MR angiography and conventional MR angiography do not differ significantly in terms of arterial stenosis grading or renal arterial variant detection.  相似文献   

2.
PURPOSE: To evaluate the interobserver and intermodality variability of conventional angiography and gadolinium-enhanced magnetic resonance (MR) angiography in the assessment of renal artery stenosis. MATERIALS AND METHODS: Fifty-four patients underwent conventional angiography and gadolinium-enhanced three-dimensional gradient-echo MR angiography. Three angiographers blinded to each other's interpretations and the MR angiographic findings assessed the conventional angiograms for renal artery stenosis. Similarly, three blinded MR imagers evaluated the MR angiograms. RESULTS: Interobserver variability for the degree of renal artery stenosis in the 107 kidneys evaluated was not significantly different between the two modalities. The mean SD of the degree of stenosis was 6.9% at MR angiography versus 7.5% at conventional angiography (alpha < or = .05, P > .05). In 70 kidneys (65%), the average degree of stenosis reported by the readers for the two modalities differed by 10% or less. In 22 cases (21%), the degree of stenosis was overestimated with MR angiography by more than 10% relative to the results of conventional angiography. In 15 cases (14%), the degree of stenosis was underestimated with MR angiography by more than 10%. CONCLUSION: Gadolinium-enhanced MR angiography permits evaluation of renal artery stenosis with an interobserver variability comparable with that of conventional angiography.  相似文献   

3.
OBJECTIVE: The purpose of this study was to evaluate diagnostic accuracy and interobserver variability of time-resolved three-dimensional gadolinium-enhanced MR angiography in the detection of renal artery stenosis in comparison with intraarterial digital subtraction angiography as the standard of reference. SUBJECTS AND METHODS: Forty consecutive patients (age range, 25-81 years; mean, 62.9 +/- 11.9 years) with suspected renal artery stenosis underwent intraarterial digital subtraction angiography and gadolinium-enhanced MR angiography, performed on a 1.5-T system with fast low-angle shot three-dimensional imaging (3.8/1.49 [TR/TE], 25 degrees flip angle, 10-sec acquisition time, and 1.5-mm partition thickness). Three time-resolved phases were obtained in a single breath-hold. Digital subtraction angiography and gadolinium-enhanced MR angiography were evaluated by four observers who studied 80 main renal arteries and 19 accessory vessels to evaluate the degree of stenosis. A stenosis reducing the intraarterial diameter by more than 50% was regarded as hemodynamically significant. Interobserver variability was calculated. RESULTS: Only one gadolinium-enhanced MR angiography study was not of diagnostic quality, as a result of failure of the power injector. All main branches were of diagnostic quality in 38 (97.4%) of the remaining 39 gadolinium-enhanced MR angiography studies. Seventeen (89.5%) of 19 accessory renal arteries were depicted with gadolinium-enhanced MR angiography. The overall sensitivity for significant stenoses was 92.9%. The overall specificity was 83.4%, and the overall accuracy was 85.9%. Interobserver variability of gadolinium-enhanced MR angiography exceeded that of digital subtraction angiography. CONCLUSION: Time-resolved three-dimensional gadolinium-enhanced MR angiography is a useful noninvasive method of screening suspected renal artery stenosis because of its easy application, short examination time, and high sensitivity despite of its higher interobserver variability.  相似文献   

4.
OBJECTIVE: Catheter-based intraarterial injections of gadolinium are useful during MR imaging-guided endovascular procedures to generate rapid vascular road maps. Using an animal model of renal artery stenosis, we tested the hypothesis that intraarterial gadolinium-enhanced MR angiography is as accurate as IV gadolinium-enhanced MR angiography and digital subtraction angiography (DSA). We also tested the hypothesis that intraarterial MR angiography uses less gadolinium than IV MR angiography. MATERIALS AND METHODS: We induced bilateral renal artery stenosis in five pigs. All pigs underwent comparative imaging with DSA, IV MR angiography, and aortic catheter-directed intraarterial MR angiography. For IV and intraarterial MR angiography, we used the same three-dimensional acquisition. We assessed differences in quantitative stenosis measurements among DSA, IV MR angiography, and intraarterial MR angiography using the Wilcoxon's signed rank test. RESULTS: Mean stenosis measurements (+/-SD) were as follows: DSA, 58% +/- 12%; IV MR angiography, 63% +/- 9.3%; and intraarterial MR angiography, 64% +/- 11%. There were no statistically significant differences in accuracy between DSA and IV MR angiography (p = 0.06), DSA and intraarterial MR angiography (p = 0.16), or IV and intraarterial MR angiography (p = 0.70). Intraarterial MR angiography used a mean gadolinium dose of 5.6 mL, compared with 9 mL for IV MR angiography. CONCLUSION: In swine, IV and intraarterial MR angiography have a similar accuracy for detecting renal artery stenosis. Intraarterial MR angiography uses smaller doses of injected gadolinium.  相似文献   

5.
PURPOSE: To compare color Doppler ultrasonography (US) with fast, breath-hold, three-dimensional, gadolinium-enhanced magnetic resonance (MR) angiography in detecting renal arterial stenosis. MATERIALS AND METHODS: Forty-five patients with clinical suspicion of renovascular disease were prospectively examined with intra- and extrarenal color Doppler US and breath-hold, gadolinium-enhanced MR angiography. Digital subtraction arteriography (DSA) was the standard of reference in all patients for the number of renal arteries and degree of stenosis. RESULTS: DSA depicted 103 arteries and 52 stenoses. Color Doppler US was nondiagnostic in two examinations. Significantly more of 13 accessory renal arteries were detected with MR angiography (n = 12) than with color Doppler US (n = 3; P <.05). For assessing all stenoses, the sensitivity and accuracy were 94% and 91%, respectively, for MR angiography and 71% and 76%, respectively, for US (P <.05). The sensitivity was higher for MR angiography (100%) than for US (79%; P <.05) in diagnosing stenoses with at least 50% narrowing. The specificity, accuracy, and negative predictive value in diagnosing stenoses of at least 50% narrowing were 93%, 95%, and 100% for MR angiography and 93%, 89%, and 90% for US. CONCLUSION: Breath-hold, gadolinium-enhanced MR angiography is superior to color Doppler US in accessory renal artery detection. Although the specificity of MR angiography is similar to that of color Doppler US, MR angiography has a better sensitivity and negative predictive value in depicting renal arterial stenoses.  相似文献   

6.
OBJECTIVE: The objective of our study was to compare the value of captopril-enhanced Doppler sonography, captopril-enhanced renal scintigraphy, and gadolinium-enhanced MR angiography for detecting renal artery stenosis. SUBJECTS AND METHODS: Forty-one patients with suspected renovascular hypertension were prospectively examined with captopril-enhanced Doppler sonography, captopril-enhanced renal scintigraphy, gadolinium-enhanced MR angiography, and catheter angiography. The sensitivity and specificity of each technique for detecting renal artery stenosis measuring 50% or greater and 70% or greater were compared using the McNemar test. Positive and negative predictive values were estimated for populations with 5% and 30% prevalence of renal artery stenosis. Kappa values for interobserver agreement were assessed for both gadolinium-enhanced MR angiography and catheter angiography. RESULTS: For detecting renal artery stenosis measuring 50% or greater, the sensitivity of gadolinium-enhanced MR angiography (96.6%) was greater than that of captopril-enhanced Doppler sonography (69%, p = 0.005) and captopril-enhanced renal scintigraphy (41.4%, p = 0.001). No significant difference in specificity was observed among modalities. For renal artery stenosis measuring 50% or greater, positive and negative predictive values were respectively 62% and 86% for captopril-enhanced Doppler sonography, 49% and 76% for captopril-enhanced renal scintigraphy, and 53% and 98% for gadolinium-enhanced MR angiography. Interobserver agreement was high for both gadolinium-enhanced MR angiography (kappa = 0.829) and catheter angiography (kappa = 0.729). CONCLUSION: Gadolinium-enhanced MR angiography is the most accurate noninvasive modality for detecting renal artery stenosis greater than or equal to 50%. The use of captopril-enhanced Doppler sonography in combination with gadolinium-enhanced MR angiography for identifying renal artery stenosis needs to be evaluated with a cost-effectiveness analysis.  相似文献   

7.
OBJECTIVE: The purpose of this study was to evaluate the diagnostic usefulness of three different MR angiographic techniques at 1.0 T. SUBJECTS AND METHODS: In 22 patients with renal artery stenosis confirmed at intraarterial catheter angiography, we also performed unenhanced and gadolinium-enhanced three-dimensional phase-contrast MR angiography and gadolinium-enhanced single breath-hold three-dimensional fast low-angle shot MR angiography. We determined circulation time to optimize signal acquisition in gadolinium-enhanced breath-hold MR angiography after bolus injection of contrast material. RESULTS: Sensitivity, defined as the detection of a hemodynamically significant stenosis (>50% luminal narrowing), was 85% for enhanced phase-contrast MR angiography, 91% for gadolinium-enhanced MR angiography, and 95% for unenhanced phase-contrast MR angiography. The combination of unenhanced phase-contrast MR angiography and gadolinium-enhanced MR angiography yielded 100% sensitivity for hilar artery stenoses. There were 13 false-positive findings with unenhanced phase-contrast MR angiography, 10 with enhanced phase-contrast MR angiography, and four with gadolinium-enhanced MR angiography (specificity: 38%, 52%, and 79%, respectively). Accessory renal arteries were not seen on unenhanced or enhanced phase-contrast MR angiography (0/8 patients) but were detected with gadolinium-enhanced MR angiography in five of the eight patients. Interobserver agreement (kappa = .62) was best with gadolinium-enhanced MR angiography. The quality of the images was unsatisfactory for adequate evaluation of segmental renal arteries with all three MR angiographic techniques. CONCLUSION: A combination of unenhanced phase-contrast MR angiography and gadolinium-enhanced MR angiography at 1.0 T proved useful as a screening protocol for renal artery stenosis.  相似文献   

8.
The authors compared the three-dimensional Fourier transform (3DFT) time-of-flight magnetic resonance (MR) angiograms in 38 patients initially studied with selective intraarterial digital subtraction angiography (DSA) for suspected arteriosclerotic disease of the carotid bifurcation. MR angiograms were successfully obtained in 65 of the 75 carotid arteries (87%) visualized with DSA. DSA and MR angiographic studies were assessed for percentage area stenosis by two independent observers on two occasions. Statistical tests indicated consistency in interpretation for each observer as well as between observers. No significant difference was found between the two modalities in ability to depict changes in percentage area stenosis. For the 32 right carotid arteries in the comparison, the median for the difference between MR angiography and intraarterial DSA was 1.83% (range, -22.38% to 55.60%); for the 33 visualized left carotid arteries, it was 0.00% (range, -20.55% to 49.95%). Receiver operating characteristic analysis indicated that technically adequate MR angiography may be a sensitive screening examination for stenoses.  相似文献   

9.
OBJECTIVE: Our objective was to evaluate use of gadolinium-enhanced three-dimensional (3D) MR angiography in the assessment of suspected arterial inflow stenosis after kidney transplantation. SUBJECTS AND METHODS: Twenty-eight consecutive patients receiving kidney transplants (26 single-kidney transplants and two en block transplants) with suspected arterial inflow stenosis were examined with two MR angiography sequences: gadolinium-enhanced 3D fast spoiled gradient-recalled (SPGR) imaging and 3D phase-contrast imaging. Twenty-four of these patients then were examined using the gold standards: either digital subtraction angiography (DSA) (n = 23) or surgery (n = 1). MR angiography and DSA studies were independently and prospectively analyzed for the presence of arterial stenoses (mild [<50%], severe [50-90%], or critical [>90%]) in the iliac, anastomotic, and renal artery segments. Two independent observers retrospectively evaluated the MR angiography sequences for ability to detect or exclude significant (> or = 50%) arterial stenoses. RESULTS: In 22 single-kidney transplants, DSA showed eight significant stenoses in 66 arterial segments. MR angiograms adequately showed 66 of 66 segments (prospective observers) and 64 of 66 segments (each retrospective observer), which were subsequently evaluated. The sensitivity and specificity of MR angiography in revealing significant stenoses were 100% and 98% (prospective analysis), 88% and 98% (retrospective observer 1), and 86% and 100% (retrospective observer 2). Concordance between observers showed kappa values exceeding .85 for all comparisons except the analysis of phase-contrast series (kappa = .62). In one en block transplant, DSA showed that stenosis was greater than 90%, although it had been graded at less than 50% with MR angiography. CONCLUSION: Gadolinium-enhanced 3D MR angiography accurately evaluated arterial inflow in single-kidney transplants.  相似文献   

10.
PURPOSE: To compare three-dimensional (3D) time-of-flight (TOF) MR angiography, contrast-enhanced MR angiography, digital subtraction angiography (DSA), and rotational angiography for depiction of stenosis. MATERIALS AND METHODS: The study had Ethics Committee approval, and each patient gave written informed consent. Forty-nine patients (18 women, mean age, 67.2 years +/- 9.1 [+/- standard deviation], and 31 men, mean age, 63.1 years +/- 8.0) with symptomatic stenosis of internal carotid artery (ICA) diagnosed at duplex ultrasonography underwent transverse 3D TOF MR angiography with sliding interleaved kY acquisition and coronal contrast-enhanced MR angiography, followed by DSA and rotational angiography within 48 hours. MR angiography was performed at 1.5-T with a cervical coil. Contrast-enhanced MR angiograms were obtained after a bolus injection of 20 mL of gadobenate dimeglumine. Maximum ICA stenosis on maximum intensity projection and source images was quantified according to NASCET criteria. Correlations for 3D TOF MR angiography, contrast-enhanced MR angiography, DSA, and rotational angiography were determined by means of cross tabulation, and accuracy for detection and grading of stenoses were calculated. Data were evaluated with analysis of variance, Wilcoxon signed rank test, and McNemar test, all at significance of P < .05. RESULTS: Ninety-eight ICAs were evaluated at contrast-enhanced MR angiography, DSA, and rotational angiography, and 97 were evaluated at 3D TOF MR angiography. Correlations for contrast-enhanced MR angiography, 3D TOF MR angiography, and DSA relative to rotational angiography were r2 = 0.9332, r2 = 0.9048, and r2 = 0.9255, respectively. Lower correlation (r2 = 0.8593) was noted for contrast-enhanced MR angiography and DSA. Respective sensitivity and specificity for detection of hemodynamically relevant stenosis relative to rotational angiography were 100% and 90% for contrast-enhanced MR angiography, 95.5% and 87.2% for 3D TOF MR angiography, and 88.6% and 100% for DSA. Four of 31 severe stenoses were underestimated at DSA, and three were underestimated at contrast-enhanced MR angiography. Three severe stenoses were underestimated at 3D TOF MR angiography, and one was misclassified as occluded. Of 13 moderate (50%-69%) stenoses, one was overestimated at contrast-enhanced MR angiography, two were underestimated and three overestimated at 3D TOF MR angiography, and two were underestimated at DSA. CONCLUSION: DSA results in an underestimation of ICA stenosis compared with rotational angiography. Contrast-enhanced MR angiography correlates best with rotational angiography.  相似文献   

11.
BACKGROUND AND PURPOSE: MR angiography is primarily and increasingly used to assess intracranial arterial stenoocclusion. However, MR angiography can cause overestimation of stenosis. Although CT angiography is accurate, it has limitations. Our purpose was to determine whether the accuracy of combined MR angiography and CT angiography is equal to that of digital subtraction angiography (DSA) in measuring stenosis and detecting major intracranial arterial occlusion. METHODS: CT angiography and intraarterial DSA were prospectively performed in 18 patients with suspected intracranial stenoocclusive disease, as revealed with MR angiography. Before DSA, two reviewers independently assessed MR intracranial angiograms. Subsequently, they assessed CT angiograms with MR angiograms. Results were compared with DSA results. The degree of stenoocclusion was categorized; stenosis of 50% or more indicated stenoocclusive disease. After the blinded study, two radiologists retrospectively reviewed the angiographic findings. RESULTS: Stenoocclusive disease was identified in 18 of 198 intracranial arteries at DSA. MR angiography had a sensitivity of 92%, a specificity of 91%, and an accuracy of 91% for the identification of stenosis of 50% or more; the addition of CT angiography yielded values of 100%, 99%, and 99%, respectively. Stenotic grades with combined CT angiography and MR angiography agreed with those of DSA in 98% of cases. In the retrospective study, CT angiography did not always correctly delineate arterial lumina with circumferential calcification and cavernous portions of the internal carotid artery. CONCLUSION: In this investigation, the evaluation of suspected stenoocclusive diseases in major intracranial arteries, the accuracy of combined MR angiography and CT angiography is equal to that of DSA in most cases.  相似文献   

12.
PURPOSE: To prospectively determine, for both digital subtraction angiography (DSA) and contrast material-enhanced magnetic resonance (MR) angiography, the accuracy of subjective visual impression (SVI) in the evaluation of internal carotid artery (ICA) stenosis, with objective caliper measurements serving as the reference standard. MATERIALS AND METHODS: Local ethics committee approval and written informed patient consent were obtained. A total of 142 symptomatic patients (41 women, 101 men; mean age, 70 years; age range, 44-89 years) suspected of having ICA stenosis on the basis of Doppler ultrasonographic findings underwent both DSA and contrast-enhanced MR angiography. With each modality, three independent neuroradiologists who were blinded to other test results first visually estimated and subsequently objectively measured stenoses. Diagnostic accuracy and percentage misclassification for correct categorization of 70%-99% stenosis were calculated for SVI, with objective measurements serving as the reference standard. Interobserver variability was determined with kappa statistics. RESULTS: After exclusion of arteries that were unsuitable for measurement, 180 vessels remained for analysis with DSA and 159 vessels remained for analysis with contrast-enhanced MR angiography. With respect to 70%-99% stenosis, SVI was associated with average misclassification of 8.9% for DSA (8.9%, 7.8%, and 10.0% for readers A, B, and C, respectively) and of 11.7% for contrast-enhanced MR angiography (11.3%, 8.8%, and 15.1% for readers A, B, and C, respectively). Negative predictive values were excellent (92.3%-100%). Interobserver variability was higher for SVI (DSA, kappa = 0.62-0.71; contrast-enhanced MR angiography, kappa = 0.57-0.69) than for objective measurements (DSA, kappa = 0.75-0.80; contrast-enhanced MR angiography, kappa = 0.66-0.72). CONCLUSION: SVI alone is not recommended for evaluation of ICA stenosis with both DSA and contrast-enhanced MR angiography. SVI may be acceptable as an initial screening tool to exclude the presence of 70%-99% stenosis, but caliper measurements are warranted to confirm the presence of such stenosis.  相似文献   

13.
RATIONALE AND OBJECTIVES: The purpose of this study was to assess interobserver variability in the interpretation of gadolinium-enhanced magnetic resonance (MR) angiograms of splanchnic vessels in patients suspected of having chronic mesenteric ischemia (CMI). MATERIALS AND METHODS: Two readers blinded to the initial interpretation retrospectively reviewed gadolinium-enhanced MR angiograms obtained for suspected CMI in 26 patients (20 women and six men; age range, 23-77 years; mean age, 61 years) who also underwent conventional angiography. Each reader graded the degree of stenosis based on the percentage diameter reduction of the celiac artery (CA), superior mesenteric artery (SMA), and inferior mesenteric artery (IMA) by using a five-point ordinal scale: 0, no stenosis: 1, mild stenosis (<50%); 2, moderate stenosis (50%-75%); 3, severe stenosis (>75%); 4, occluded artery. Using the conventional angiogram as a reference standard, authors determined sensitivity and specificity for each observer, assigning two thresholds (grades 2 and 3) as significant stenoses. A kappa statistic (kappa) measured interobserver agreement. RESULTS: With grade 2 stenosis used as a threshold, cumulative accuracies for detecting significant stenosis were 0.95 (95% confidence interval, 0.86-0.99) for reader A and 0.97 (0.88-1.0) for reader B. Interobserver agreement for grading proximal splanchnic stenosis was 0.90 for CA, 0.92 for SMA, and 0.48 for IMA. CONCLUSION: Gadolinium-enhanced MR angiography is reproducibly accurate for detection of proximal splanchnic artery stenosis, with good to excellent interobserver agreement.  相似文献   

14.
PURPOSE: To evaluate whether and to what extent greater number of projection images obtained at three-dimensional (3D) time-of-flight (TOF) magnetic resonance (MR) angiography versus conventional digital subtraction angiography (DSA) causes overestimation of internal carotid arterial (ICA) stenosis. MATERIALS AND METHODS: DSA (two or three projections), rotational angiography (16 or 32 projections), and 3D TOF MR angiography (12 projections) were performed in 47 stenotic ICAs of 38 symptomatic patients. Two observers independently measured maximum stenosis, and the mean differences among MR angiography, DSA, and rotational angiography were compared. RESULTS: Three rotational and five MR angiograms were nondiagnostic. Seven MR angiograms of ICA stenoses showed a signal void and were excluded from analysis. On the remaining 32 angiograms, mean differences in maximum stenosis for observers 1 and 2, respectively, were 7% (95% CI: 3%, 12%) and 8% (95% CI: 3%, 13%) at MR angiography versus DSA and 2% (95% CI: -2%, 7%) and -1% (95% CI: -5%, 3%) at MR angiography versus rotational angiography. ICA stenosis was graded significantly higher at MR angiography versus DSA, whereas, it was not overestimated at MR angiography versus rotational angiography. The difference in maximum stenosis at MR angiography versus DSA was significantly different from that of MR angiography versus rotational angiography. CONCLUSION: Apparent overestimation of ICA stenosis at 3D TOF MR angiography versus conventional DSA may be partly explained by the greater number of projection images available at 3D TOF MR angiography.  相似文献   

15.
OBJECTIVE: The aim of our study was to evaluate a three-dimensional gadolinium-enhanced breath-hold MR angiography sequence using standard MR gradients in detecting renal artery stenosis. SUBJECTS AND METHODS: Forty-two patients referred for angiography for suspected renal artery stenosis underwent both conventional digital subtraction angiography (DSA) and MR angiography. MR angiography was performed on a 1.5-T scanner with standard gradients. A fast multiplanar spoiled gradient-echo sequence was used with the following parameters: TR/TE, 10.3/1.9; flip angle, 45 degrees; field of view, 36 x 32 cm; matrix size, 256 x 128; one excitation; volume thickness, 70 mm; and partitions, 28. Gadolinium was administered IV as a dynamic bolus of 30-40 ml. Conventional and MR angiographic images were interpreted by two radiologists in consensus. RESULTS: DSA revealed 87 renal arteries, of which 79 were in 35 patients with native kidneys and eight arteries were in seven patients with transplanted kidneys. Gadolinium-enhanced MR angiography showed 85 (98%) of 87 renal arteries. Seventeen patients had 20 significant (>50% stenosis) renal artery stenoses and five patients had five occluded renal arteries revealed by DSA. MR angiography revealed 85 renal arteries (98%), 20 stenoses (100%), and five occlusions (100%). Gadolinium-enhanced MR angiography led to one false-positive interpretation for renal artery stenosis and no false-negative interpretations. Thus, the sensitivity, specificity, and accuracy of MR angiography for renal artery stenosis were 100%, 98%, and 99%, respectively. CONCLUSION: The MR angiography pulse sequence we used was an effective and reliable technique for the diagnosis of renal artery stenosis. The sequence can be performed on widely available MR equipment that does not require fast gradient hardware.  相似文献   

16.
PURPOSE: The danger of limb loss as a consequence of acute occlusion of infrapopliteal bypasses underscores the requirement for careful patient follow-up. The objective of this study was to determine the agreement and accuracy of contrast material-enhanced moving-table magnetic resonance (MR) angiography and duplex ultrasonography (US) in the assessment of failing bypass grafts. In cases of discrepancy, digital subtraction angiography (DSA) served as the reference standard. MATERIALS AND METHODS: MR angiography was performed in 24 consecutive patients with 26 femorotibial or femoropedal bypass grafts. Each revascularized limb was divided into five segments--(i) native arteries proximal to the graft; (ii) proximal anastomosis; (iii) graft course; (iv) distal anastomosis; and (v) native arteries distal to the graft-resulting in 130 vascular segments. Three readers evaluated all MR angiograms for image quality and the presence of failing grafts. The degree of stenosis was compared to the findings of duplex US, and in case of discrepancy, to DSA findings. Two separate analyses were performed with use of DSA only and a combined diagnostic endpoint as the reference standard. RESULTS: Image quality was rated excellent or intermediate in 119 of 130 vascular segments (92%). Venous overlay was encountered in 26 of 130 segments (20%). In only two segments was evaluation of the outflow region not feasible. One hundred seventeen of 130 vascular segments were available for quantitative analysis. In 109 of 117 segments (93%), MR angiography and duplex US showed concordant findings. In the eight discordant segments in seven patients, duplex US overlooked four high-grade stenoses that were correctly identified by MR angiography and confirmed by DSA. Percutaneous transluminal angioplasty was performed in these cases. In no case did MR angiography miss an area of stenosis of sufficient severity to require treatment. Total accuracy for duplex US ranged from 0.90 to 0.97 depending on the reference standard used, whereas MR angiography was completely accurate (1.00) regardless of the standard definition. CONCLUSION: Our data strongly suggest that the accuracy of MR angiography for identifying failing grafts in the infrapopliteal circulation is equal to that of duplex US and superior to that of duplex US in cases of complex revascularization. MR angiography should be included in routine follow-up of patients undergoing infrapopliteal bypass surgery.  相似文献   

17.
RATIONALE AND OBJECTIVES: The authors compared diagnostic accuracy of maximum intensity projection (MIP), multiplanar reformatting (MPR), and three-dimensional (3D) volume rendering (VR) in the evaluation of gadolinium-enhanced 3D magnetic resonance (MR) angiography of the renal arteries. They hypothesized that VR is as accurate as or more accurate than MIP and MPR at depicting renal artery stenosis. MATERIALS AND METHODS: The study group comprised 28 consecutive patients who underwent gadolinium-enhanced 3D MR angiography of the renal arteries. Studies were postprocessed to display images in MIP, MPR, and VR formats. Digital subtraction angiography (DSA), when performed (nine of 28 patients), was the standard for comparison. For each main renal artery, an estimate of percentage stenosis was made for any stenoses detected by three independent radiologists. For calculation of sensitivity, specificity, and accuracy, MR angiographic stenosis estimates were categorized as mild (0%-39%), moderate (40%-69%), or severe (> or = 70%). DSA stenosis estimates of 70% or greater were considered hemodynamically significant. RESULTS: Analysis of variance demonstrated MIP estimates of stenosis were statistically greater than VR estimates in two readers and greater than MPR estimates in all readers for all patients. MIP images also showed the largest mean difference from DSA stenosis estimates for all three readers. For both VR and MPR, mean differences between MR angiographic stenoses estimates and DSA estimates reached significance for only one reader, whereas, for MIP versus DSA, mean differences reached significance for all three readers. Although not statistically significant compared with DSA, accuracies of VR (87%) and MPR (89%) were greater than that of MIP (81%). CONCLUSION: In this pilot study, MIP was the least accurate of the three image display algorithms tested. VR and MPR yielded similar values for each method of comparison.  相似文献   

18.
BACKGROUND AND PURPOSE: Since 1996, several preliminary studies have shown the usefulness of contrast material-enhanced MR angiography for imaging supraaortic vessels. The aim of this study was to compare the accuracy of contrast-enhanced 3D MR angiography with that of digital subtraction angiography (DSA) in the evaluation of carotid artery stenosis. METHODS: A blinded comparison of first-pass contrast-enhanced MR angiography with conventional DSA was performed in 120 patients (240 arteries). MR angiography was performed with a 1.5-T magnet with gradient overdrive equipment, by using a coronal radiofrequency-spoiled 3D fast low-angle-shot sequence after the intravenous injection of gadodiamide. The guidelines of the North American Symptomatic Carotid Endarterectomy Trial for measuring stenosis of the internal carotid artery were applied on maximum intensity projection (MIP) images and conventional catheter angiograms. RESULTS: Grading of stenoses on MR angiograms agreed with grading of stenoses on DSA images in 89% of arteries. In the severe stenosis group (70-99%), agreement was 93%. All internal carotid occlusions (n = 28) and seven of nine pseudo-occlusions were accurately detected with contrast-enhanced MR angiography. The correlation between MR angiography and DSA for determination of minimal, moderate, and severe stenoses and occlusion was statistically significant (r = 0.91, P<.001). CONCLUSIONS: This investigation with a large number of patients confirms that contrast-enhanced MR angiography could become a diagnostic alternative to DSA in the treatment of patients with carotid artery disease.  相似文献   

19.
OBJECTIVE: The purpose of our study was to evaluate the diagnostic accuracy of hybrid MR angiography by comparison with digital subtraction angiography (DSA) in diabetic patients with critical limb ischemia. SUBJECTS AND METHODS: Thirty-one patients prospectively underwent both hybrid MR angiography and DSA. The hybrid MR angiography study consisted of high-resolution MR angiography of a single calf and foot using a contrast-enhanced 3D gradient-echo volumetric interpolated breath-hold examination with surface coils, followed by three-station bolus chase MR angiography with a dedicated peripheral vascular coil. Two blinded reviewers separately analyzed maximum-intensity-projection hybrid MR angiograms and DSA images. The peripheral vessels were divided into 10 anatomic segments for review. The status of each segment was graded as normal, stenosis less than 50% in diameter, stenosis greater than 50%, or occluded. The sensitivity and specificity of hybrid MR angiography were determined using DSA as the gold standard. Treatment options were considered separately from the results of each examination. RESULTS: Among 310 analyzed segments, the sensitivities of hybrid MR angiography for stenosis and occlusion were, respectively, 95% and 95% for reviewer 1 and 96% and 90% for reviewer 2. The specificities of hybrid MR angiography for stenosis and occlusion were, respectively, 98% and 98% for reviewer 1 and 98% and 99% for reviewer 2. In 25 patients (81%), the quality of bolus chase MR angiography images was insufficient to assess runoff arteries. All treatments proposed on the basis of DSA findings were endorsed by hybrid MR angiography findings. Eleven more treatments were formulated on the basis of hybrid MR angiography findings. Of these, four were due to overestimation of stenosis on MR angiography and seven were due to the detection of patent infrageniculate arteries on hybrid MR angiography that were not detected on DSA. CONCLUSION: Hybrid MR angiography depicts runoff arteries not seen on DSA. Hybrid MR angiography may be useful for treatment planning in selected diabetic patients with critical limb ischemia.  相似文献   

20.
PURPOSE: To compare computed tomographic (CT) angiography and magnetic resonance (MR) angiography for preoperative evaluation of living renal donors. MATERIALS AND METHODS: Thirty-five living renal donors underwent preoperative contrast material-enhanced CT angiography and gadolinium-enhanced MR angiography. Each study was interpreted by two independent radiologists blinded to all other studies and to interpretations provided by other reviewers. Eighteen kidneys had surgical correlation. RESULTS: CT demonstrated 33 supernumerary arteries in 19 patients, bilateral solitary arteries in 16 patients, and 18 proximal arterial branches in 16 patients. MR demonstrated 26 supernumerary arteries in 15 patients, bilateral solitary renal arteries in 20 patients, and 21 proximal arterial branches in 16 patients. Interobserver agreements for MR (kappa = 0. 74) and CT (kappa = 0.73) were similar to the agreement between MR and CT (kappa = 0.74). Among the kidneys chosen for nephrectomy, one small accessory artery and one proximal arterial branch were missed with CT and MR. Two of the accessory arteries suggested at CT were not found at nephrectomy. By averaging data for both modalities, supernumerary arteries were present in 49% of kidney donors and were bilateral in approximately 17%. Proximal arterial branches were present in 46% of kidney donors. CONCLUSION: Preoperative CT and MR angiography of the renal arteries in renal donors demonstrate substantial agreement. Interobserver disagreement in the interpretation of CT and MR angiograms is related to 1-2-mm-diameter vessels.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号