首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Background: Atrial rate-adaptive pacing may improve cardiopulmonary reserve in patients with left ventricular dysfunction.
Methods: A randomized, blinded, single-crossover design enrolled dual-chamber implantable defibrillator recipients without pacing indications and an ejection fraction ≤40% to undergo cardiopulmonary exercise treadmill stress testing in both atrial rate-adaptive pacing (AAIR) and ventricular demand pacing (VVI) pacing modes. The primary endpoint was change in peak oxygen consumption (VO2). Secondary endpoints were changes in anaerobic threshold, perceived exertion, exercise duration, and peak blood pressure.
Results: Ten patients, nine males, eight with New York Heart Association class I, mean ejection fraction 24 ± 7%, were analyzed. Baseline VO2 was 3.6 ± 0.5 mL/kg/min. Heart rate at peak exercise was significantly higher during AAIR versus VVI pacing (142 ± 18 vs 130 ± 23 bpm; P = 0.05). However, there was no difference in peak VO2 (AAIR 23.7 ± 6.1 vs VVI 23.8 ± 6.3 mL/kg/min; P = 0.8), anaerobic threshold (AAIR 1.3 ± 0.3 vs VVI 1.2 ± 0.2 L/min; P = 0.11), rate of perceived exertion (AAIR 7.3 ± 1.5 vs VVI 7.8 ± 1.2; P = 0.46), exercise duration (AAIR 15 minutes, 46 seconds ± 2 minutes, 54 seconds vs VVI 16 minutes, 3 seconds ± 2 minutes, 48 seconds; P = 0.38), or peak systolic blood pressure (AAIR 155 ± 22 vs VVI 153 ± 21; P = 0.61) between the two pacing modes.
Conclusion: In this study, AAIR pacing did not improve peak VO2, anaerobic threshold, rate of perceived exertion, or exercise duration compared to VVI backup pacing in patients with left ventricular dysfunction and no pacing indications.  相似文献   

2.
The observation of a close relationship of heart rate to oxygen uptake (HH-VO2) and heart rate to minute ventilation (HR-VE)has been shown to be of particular value in rate variable pacing. However, the impact of anaerobic threshold (AT)for the HH-VO2 and HH-VE slope has been studied Jess. Twenty-three male and 16 female subjects, mean age 52 ± 7 years, were selected in whom complete heart catherization and extensive noninvasive sludies excluded major cardiopulmonary disease. Semisupine bicycle exercise testing with analysis of respiratory gas exchange was performed using a ramping work rate protocol with work increments of 20 watts/min. At the respiratory AT, determined by the V slope method, oxygen uptake (VO2-AT)was 15.2 ± 3.0 mL/kg in males versus 13.8 ± 2.3 mL/kg in females and heart rate (HR-AT)was 109 ± 18 beats/min versus 119 ± 20 beats/min, respectively. Heart rate was highly correlated (r ±0.9)to VO2 and minute ventilation (VE). A linear regression for HR-VO2, however, was found only in 16/39 and for HR-VE in 11/39 subjects. Assuming the AT as the breakpoint of two linear curves, it could be demonstrated that compared to low exercise HR appeared to increase at maximal exercise more in relation to VO2 but less in relation to VE; in men the individual slopes for HR-VO2 were 2.6 ± 0.7 below but 3.2 ± 1.0 above AT (P < 0.05) and the slopes for HH-VE were 1.6 ± 0.5 below but 1.0 ± 0,4 above AT (P < 0.05). Similarly, in women the individual slopes for HR-VO2 were 3.7 ± 1.4 below but 4.3 ± 1.4 above AT (P < 0.05)and the slopes for HR-VE were 2.1 ± 0.9 below but 1.3 ± 0.4 above AT (P < 0.05). The differences between male and female subjects were significant. The nonlinear behavior of the HB-VO2 and HR-VE relation from rest to maximal exercise should have a particular impact in respiratory controlied pacing systems.  相似文献   

3.
The EXCEL VR, an accelerometer-based pacemaker (AC), and the Legend, a pacemaker utilizing a piezoelectric crystal (PZ), were compared under ergometric conditions and during stair climbing to assess the appropriateness of their rate responses. The pacemakers, programmed to the manufacturers' nominal settings in order to compare different technologically based sensors under identical conditions, were strapped over subjects' left mid-pectoral region. Placement of the devices was randomized to control for positional effects. Ten healthy subjects (55-72 years) completed a graded exercise treadmill test to 80% of maximum predicted heart rate (HR). An additional group of ten subjects (50-66 years) completed exercise protocols involving bicycle ergometry and stair climbing. Throughout all tests, pacemaker pulse rates and subjects' intrinsic HR were monitored continuously. For the treadmill exercise, the average correlations between the AC and PZ pacemakers' pulse rate and HR for the group as a whole were r = 0.92 and r = 0.82, respectively. Individual subject comparisons were also made between each pacemaker rate and intrinsic HR. The mean difference from intrinsic rate was 11 ppm for the AC pacemaker and 24 ppm for the PZ pacemaker. In addition, the PZ pacemaker's maximal pulse rate was significantly lower (105 +/- 9.6 ppm) than the other two rates (AC 137 +/- 6 ppm; intrinsic HR 129 +/- 2 beats/min). Throughout the bicycle ergometry testing, the intrinsic HR was higher than the AC and PZ pacing rates. However, the AC's rate was significantly higher than the PZ's rate. When subjects ascended stairs, the intrinsic HR and AC rate were closely correlated, but the PZ rate was significantly lower.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

4.
Demand failures during permanent cardiac pacing were studied in four patients with coronary heart disease and cardiomyopathies, by means of in vivo and in vitro analyses of the pacemaker system. A common feature of the electrogram analyses (except during a second replacement in one patient), was extremely low values of amplitudes (0.77-4.36 mV) and maximum derivatives (0.16-1.06 V/sec). In spite of low electrogram amplitudes, the myocardial threshold values were low in all patients. An attempt in one patient at unipolarizing a bipolar system made the adaptation between electrogram and pulse generator more difficult. Autopsy showed that the tip of the bipolar electrode was positioned in a fibrotic area of the myocardium. The signal available for the sensing circuit will also be reduced because of voltage division between the electrode/tissue interface impedance and the input impedance of the pulse generator. Although the pulse generators used had a high input impedance (10-50 K omega), the tissue interface impedance may have caused a further reduction in the electrogram amplitude of 10-30%. This may have contributed to demand failure. In vitro studies confirmed that test pulses with characteristics similar to those of the electrograms found in this investigation, were inadequate for pacemaker inhibition. Special care should be taken during electrogram recordings in patients with severe myocardial disease. One should consider the implantation of a high sensitivity pulse generator or the recently introduced sensitivity programmable pulse generators as first choice for this group of patients.  相似文献   

5.
Après ľintroduction de la stimulation en VAT, le mode stimulation en VDD représente un progrés. Ses bénéfices physiologiques sont maintenant bien prouvés alors que cette stimulation n'est utilisée que dans 1 % des cas. Les progrés de la program-mation de la période refractaire auriculaire permettant de maitriser les tachycardies induites laissent espérer une augmentation du pourcentage ďutilisation du mode de stimulation en VDD chez les malades porteurs ďun bloc de haul degré induit par ľeffort et avec fonction sinusale stable.
The design of atrial synchronous, ventricular inhibited (VDD) pacemakers has been improved. Physiologic long-term benefit has now been established, although this mode of pacing accounts for approximately one percent of implanted devices. With the ultimate control of pacemaker-mediated lachycardia through atrial refractory programming close at hand or already available, one might expecl an increase in VDD pacing in patients with exercise-induced high degree heart block and stable sinus node function.  相似文献   

6.
The efficacy and safety of external programmable automatic antitachycardia pacemakers (ATPs) used in the critical care setting for recurrent sustained monomorphic ventricular tachycardia (VT) was evaluated. Ten patients who had failed a mean of 4.0 +/- 1.4 antiarrhythmic medications (range 2-7) and who had previously required electrical cardioversion for VT were enrolled. Prior to ATP use, successful overdrive pacing termination of VT was demonstrated in all patients. Intertach (Intermedics, Inc.; n = 9) and Orthocor II (Cordis, Inc.; n = 1) ATPs were attached to temporary bipolar transvenous or epicardial pacing leads. Mean patient age was 66.4 +/- 11.5 years, and mean left ventricular ejection fraction was 22 +/- 7.5%. At the time of initial ATP use, mean VT cycle length was 347 +/- 88 msec (range 280-550 msec). A burst scanning antitachycardia pacing algorithm was used in each patient; one patient was also treated with a fixed rate burst adapted to VT cycle length. The duration of ATP use ranged from 2-25 days (median 5), successfully terminating greater than 3,369 VT episodes (median 3, range 0 to greater than 3,103 episodes per-patient). Two episodes of ATP induced rate acceleration occurred, each successfully terminated by the ATP. Only two patients required external cardioversion during ATP use, one for primary ventricular fibrillation and one for rapid polymorphic VT associated with antiarrhythmic drug withdrawal. ATPs also provided antibradycardia pacing and allowed for serial programmed ventricular stimulation. No complications were associated with transvenous catheter or ATP use.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

7.
Inappropriate tachycardias may be observed in patients with DDDR pacemakers equipped with an activity sensor and a QT sensor due erroneous T wave sensing, provoked by drug treatment that prolongs cardiac repolarization.  相似文献   

8.
9.
Torsades de pointes, a distinctive type of polymorphous ventricular tachycardia, may be induced by critically timed ventricular stimulation during electrophysiologic studies or, rarely, in patients with temporary or permanent ventricular pacemakers. The following case illustrates how, when temporary ventricular pacing is instituted to maintain heart rate in a patient with a defective permanent ventricular pacemaker, this potentially fatal arrhythmia may occur as a complication of interaction between the two pacemakers.  相似文献   

10.
Although the beneficial effects of DDD pacing are well known, currently available ICDs provide only fixed rate ventricular antibradycardia pacing. In a consecutive series of 139 patients with ICDs, we have analyzed the need for antibradycardia pacing and the indications for DDD pacing. We also report our initial experience with the Defender 9001 (ELA Medical, France) DDD-ICD. Out of 139 patients, 25 (18%) were in need of antibradycardia pacing. Ten patients already had a pacemaker at the time of ICD implantation and ten other patients had a conventional pacemaker indication at that time. Five patients became pacemaker dependent during a follow-up of 20 ± 8 months. The disorders necessitating pacemaker therapy were high degree AV conduction disturbances in 72%, sick sinus syndrome in 12%, and AF with a slow ventricular response in 16% of patients. Based upon current indications, DDD pacing was indicated in 20 (80%) of 25 patients. The Defender 9001 DDD-ICD (ELA Medical) was used in two patients with ischemic cardiomyopathy and pacemaker syndrome with VVI pacing. Cardiac output during DDD pacing increased by 36% in one patient with an increase in VO2 max during exercise of 29%. The other patient showed an increase in cardiac output of 50% with DDD pacing, and, while unable to exercise with VVI pacing, had a VO2max of 24 mL/kg per minute during DDD pacing. Up to 18% of our ICD patients are in need of antibradycardia pacing. Of these pacemaker dependent patients, 80% have an indication for DDD pacing. Our first clinical experience with a DDD-ICD confirms the hemodynamic benefit of AV synchronous pacing in ICD patients with pacemaker syndrome.  相似文献   

11.
Three patients with uncertain pacemaker electrode position on plain film radiography were studied with fast cine cardiovascular computed tomography (CT) imaging. The value of this new technique in determining the position of pacing electrodes is discussed.  相似文献   

12.
To develop a dromotropic-controlled rate adaptive algorithm for patients with sick sinus syndrome (SSS) and intact AV conduction, 14 pace-maker patients with SSS underwent cardiopulmonary exercise testing (CPX). During exercise, the pace-maker was programmed in an AAT mode without rate adaptation, whereby 3 patients developed supraventricular arrhythmia and 11 patients kept sinus rhythm. Chronotropic incompetence (CI) at heart rate (HR) < 95 beats/min at the anaerobic threshold (AT) was found in five patients. In patients with chronotropic competence (CC), the HR increase was significantly greater than in CI patients (rest: 73.2 +/- 12.6 vs. 64.2 +/- 4.0 beats/min;AT:101.2 +/- 6.2 vs. 82.0 +/- 5.1 beats/min;peak: 135.2 +/- 10.7 vs. 103.2 +/- 10.9 beats/min). There was no significant difference in the AVD between CC and CI patients (rest: 167.7 +/- 38.6 vs. 170.8 +/- 22.5 ms, AT: 156.2 +/- 30.7 vs. 163.6 +/- 21.6 ms, peak: 144.7 +/- 29.0 vs. 152.4 +/- 15.0 ms). The correlation coefficient between HR increase and VO2 was +1.0 and between AVD decrease and VO2 - 1.0 in both groups. An increase in pacing rate from 75 beats/min to 120 beats/min without exercise (overpacing) led to a prolongation of the AV interval of about 30.6 +/- 14.2 ms. Based on this closed loop control with negative feedback, a dromotropic rate adaptive algorithm for patients with SSS and intact AV conduction could be developed.  相似文献   

13.
The danger in utilizing electrocautery during a surgical procedure on a pacemaker patient depends, to a great extent, on the position of the electrodes. We have studied this influence in an experimental model consisting of a plexiglass tank filled with a saline solution. Seven pacemakers were successively attached to an immersed and fixed frame and connected to a lead whose tip remains in the same location throughout the experiments. An ERBOTOM T 400 C generator (450 KHz) was used in an unmodulated unipolar mode at a maximum output (400 W). The high frequency current was delivered between a patch located successively at six preset positions in the tank and another electrode applied to 176 surface locations. For each position, we measured the currents in the lead with a separate measurement circuit connected in parallel on the same lead. Results were displayed on a map. Regardless of the patch position, currents were: (1) at a maximum when high frequency was delivered close to the pacemakers and around the tip of the lead; (2) negligible when applied to the path followed by the lead; and (3) a function of the distance between electrodes. These results may help to formulate recommendations to prevent accidents when using electrocautery in pacemaker patients.  相似文献   

14.
Two patients who had DDD pacemakers inserted for symptomatic sick, sinus syndrome developed sustained upper-rate limit pacing. It was demonstrated in these two patients that pacemaker-mediated tachycardia was due to tracking of atrial flutter. DDD pacemakers should be used with caution in patients with the sick sinus syndrome and associated atrial tachyarrhythmias. Medical treatment of recurrent atrial tachyarrhythmias may allow patients to remain in the DDD mode.  相似文献   

15.
FRENCH, W.J., ET AL.: Relationship Between Right Atrial and Mixed Venous Oxygen Saturation and Heart Rate During Exercise in Normal Subjects and Patients with Cardiac Disease. An ideal sensing variable for use in rate responsive pacemakers should measure a physiological parameter that closely correlates with heart rate during various activities in a diverse group of subjects. Nineteen patients, 12 normal and 7 patients with heart disease, were studied to assess the relationship between mixed venous oxygen saturation and heart rate. In patients with heart disease right atrial oxygen saturation and heart rate were also compared. Each subject underwent pulmonary artery catheterization and performed seated cycle ergometer exercise. Gas exchange and heart rate were measured continuously and blood sampled at frequent intervals. Normal patients were studied at rest and during steady-state exercise (mean work rate 149 watts). Patients were studied at rest, steady-state exercise [mean work rate 37 watts), and during incremental exercise (5–10 wattsimin) to tolerance. There were 248 paired right atrial or mixed venous oxygen saturation/heart rate observations obtained. Changes in mixed venous oxygen saturation and heart rate were not substantially altered by fitness or cardiac disease. Rate responsive pacemakers sensing changes in oxygen saturation may be a superior sensing variable for both normal and patients with heart disease.  相似文献   

16.
Single chamber rate responsive pacing offers many potential advantages over the more complex dual chamber atrial tracking pacing mode in children, and the preservation of atrioventricular synchrony could be unnecessary in selected groups of pediatric patients. Twenty-two pediatric patients (age range 9 months to 12 years; mean 6.5 years) had implantation of ventricular rate responsive (VVIR) pacemakers over a 2-year period. All patients had chronic third-degree atrioventricular block, and a normal ventricular function at rest. During the follow-up each patient underwent a 24-hour Holter monitoring, and ten performed a graded treadmill test in both ventricular fixed rate (VVI) and rate responsive (VVIR) pacing mode. Paced ventricular rates were found to be normal for age in all 22 patients; maximum rate did not reach the higher programmed rate during daily activities in any patient. Comparing the mean paced ventricular rate to the mean rates of blocked P waves, six patients showed a difference of more than 20 beats/min, which induced the pacemaker parameters to be reprogrammed. In all patients a significant correlation was found between variations of paced ventricular rate and variations of spontaneous blocked atrial rhythm (P < 0.05); this correlation persisted in the subsequent Holter controls in the ten patients with longer follow-up. Exercise tolerance resulted normal in the ten patients who performed a treadmill test either in VVIR or VVI mode, with increased maximal heart rates and maximal systolic blood pressure in VVIR mode (P < 0.0013). Rate responsive ventricular pacemakers seem to adequately respond to the physiological needs of daily life of this selected group of children requiring permanent pacing.  相似文献   

17.
ANDERSON, M.H., ET AL.: Ventricular Pacing from the Atrial Channel of a DDD Pacemaker: A Consequence of Pacemaker Twiddling? The breakdown of pacemaker lead insulation under conditions of mechanical stress leading to failure of pacing is well recognized. We present a case where adjacent breakdown of insulation in two unipolar pacing leads resulted in inappropriate ventricular pacing. Replacement of the leads rectified the problem. [PACE, Vol. 13, December, Part I 1990)  相似文献   

18.
In this study, we used Holter pacemakers in a group of 13 patients affected by severe carotid sinus syndrome in order to evaluate its evolution. All the patients had one to three syncopal episodes and frequent other symptoms such as fainting, dizziness, lightheadedness and pre-syncope interferring with their daily activity so that pacemaker therapy was considered necessary. Patient selection criteria were: presence of the isolated cardioinhibitory type, absence of associated sinus dysfunction and absence of symptomatic WI pacemaker effect. All the patients received a Micropacer 1 device; among special functions, bradycardia events counter was activated and programmed so that each sequence of three consecutives beats at a cycle length 1.5 sec (i.e., 4.5 sec total interval) could he recognized and stored in its memory. The follow-up lasted 13±7 months. Brady events occurred in eight out of 13 patients (62%), during this period. Syncope and major symptoms disappeared in ail the patients; mild dizziness recurred rarely in two patients and were not linked to brady-events recording. In conclusion, disappearance of severe symptoms observed after pacemaker implant in cardioinhibitory carotid sinus syndrome seems to depend from pacing therapy, in most cases, yet from the benign natural course of the disease in some other cases.  相似文献   

19.
The purpose of this paper is to specify the mathematical relationship between spontaneous AV interval (AVI) and heart rate (HR), the amplitude and rate of variation of AVI, and the physiological factors likely to affect these characteristics. Ten patients with healthy hearts were studied. Two catheter electrodes were positioned in the right atrium and at the tip of the right ventricle respectively, allowing the detection of endocardial signals. The AV and AA intervals for each heart cycle were digitized to on accuracy of ± 1 msec. Measurements were made at rest, then during a stress test on an exercise bicycle, and finally during the recovery phase. The results show that adaptation is very precise and takes place instantly. Any variation in heart rate causes an immediate, inversely proportional variation in AVI. Adaptation follows a linear pattern, generally with relatively low amplitude and an average AVI reduction of 27.5 ±11.2 msec for an average HR increase of 78.7 ± 22.5 bpm, i.e., a decrease of 4 ± 2.1 msec for an HR variation 0f 10 bpm. The amplitude and variation rate of AVI seem to be independent 0f the age and base value of the PR interval. These observations may be useful for designing new VDD or DDD pacemakers that automatically adapt the AV interval to the instantaneous heart rate. The hemodynamic benefits 0f this adaptation were also demonstrated.  相似文献   

20.
PRINZEN, F.W., et al. : Relation Between the Pacing Induced Sequence of Activation and Left Ventricu-lar Pump Function in Animals. The main goal of this article was to review animal experimental work on the effect of asynchronous activation on ventricular pump function. During normal sinus rhythm and atrial pacing, the Purkinje system contributes significantly to the rapid electrical activation of the ventricles. In contrast, during ventricular pacing the impulse is almost exclusively conducted through the normal myocardium. As a consequence, electrical activation of the ventricles becomes asynchronous and has an abnormal sequence. The abnormal impulse conduction causes considerable disturbances to occur in regional systolic fiber shortening, mechanical work, blood flow, and oxygen consumption; low values occurring in early activated regions and values above normal being present in late activated regions. Many animal studies have now shown that the abnormal electrical activation, induced by ventricular pacing, leads to a depression of systolic and diastolic LV function. Pacing at the right ventricular apex (the conventional pacing site) reduces LV function more than pacing at the high ventricular septum or at LV sites. In canine hearts with experimental LBBB, LV pacing significantly improves LV pump function. Differences in LV pump function between (combinations of) pacing sites are poorly correlated with QRS duration. Therefore, the cause of the depression of LV function during abnormal electrical activation appears to be a combination of the asynchrony and the sequence of activation. These experimental findings justify continuing attention for optimizing the site(s) of ventricular pacing in patients with normal and abnormal ventricular impulse conduction.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号