首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Introduction and objective:

The aim of this study was to evaluate the ability of root canal cleaning of the RaCe rotary instrumentation system (FKG Dentaire – La-Cheaux-de Fonds – Switzerland), compared to manual filing with Stainless Steel K-files (Maillefer Instruments – Ballaigues – Switzerland).

Material and Method:

Twenty extracted human teeth (maxillary molars) were selected and their pulp tissue was removed after coronal access. The root canals were filled with a dye (India ink) and allowed to dry for 48 hours, followed by establishment of the working length of the mesiobuccal root; then, half of the specimens were instrumented by the modified Oregon technique and the other half were instrumented by crown-down sequence of the RaCe system. After preparation, the teeth were longitudinally sectioned and evaluated according to the amount of remaining dye.

Results:

Data obtained were registered as numerical scores, and the arithmetic means were compared between groups using the Mann Whitney test. Both techniques were unable to completely clean the interior of the root canals, with a better performance of the manual technique only at the middle third.

Conclusion:

It could be concluded that the RaCe system was able to provide satisfactory cleaning, similar to that obtained by the manual instrumentation technique.  相似文献   

2.

Objective:

The efficiency of rotary, manual and ultrasonic root canal instrumentation techniques was investigated in proximally flattened root canals.

Material and Methods:

Forty human mandibular left and right central incisors, lateral incisors and premolars were used. The pulp tissue was removed and the root canals were filled with red die. Teeth were instrumented using three techniques: (i) K3 and ProTaper rotary systems; (ii) ultrasonic crown-down technique; and (iii) progressive manual technique. Roots were bisected longitudinally in a buccolingual direction. The instrumented canal walls were digitally captured and the images obtained were analyzed using the Sigma Scan software. Canal walls were evaluated for total canal wall area versus noninstrumented area on which dye remained.

Results:

No statistically significant difference was found between the instrumentation techniques studied (p<0.05).

Conclusion:

The findings of this study showed that no instrumentation technique was 100% efficient to remove the dye.  相似文献   

3.

OBJECTIVE:

The purpose of this study was to evaluate the distribution of microorganisms in the root canal system (RCS) and periapical lesions of dogs'' teeth after rotary instrumentation and placement of different calcium hydroxide [Ca(OHy-based intracanal dressings.

MATERIALS AND METHODS:

Chronic periapical lesions were experimentally induced in 80 premolar roots of four dogs. Instrumentation was undertaken using the ProFile rotary system and irrigation with 5.25% sodium hypochlorite. The following Ca(OH)2-based pastes were applied for 21 days: group 1 - Calen (n=18); group 2 - Calen+CPMC (n=20); group 3 - Ca(OH2 p.a. + anaesthetic solution (n=16) and group 4 - Ca(OH2 p.a.+ 2% chlorhexidine digluconate (n=18). Eight root canals without endodontic treatment constituted the control group. Histological sections were obtained and stained with Brown & Brenn staining technique to evaluate the presence of microorganisms in the main root canal, ramifications of the apical delta and secondary canals, apical cementoplasts, dentinal tubules, areas of cemental resorption and periapical lesions. The results were analyzed statistically by the Mann-Whitney U test (p<0.05).

RESULTS:

The control group showed the highest prevalence of microorganisms in all sites evaluated. Gram-positive cocci, bacilli and filaments were the most frequent morphotypes. Similar microbial distribution patterns in the RCS and areas of cementum resorption were observed in all groups (p>0.05). The percentage of RCS sites containing microorganisms in groups 1, 2, 3, 4 and control were: 67.6%, 62.5%, 78.2%, 62.0% and 87.6%, respectively.

CONCLUSION:

In conclusion, the histomicrobiological analysis showed that the rotary instrumentation and the different calcium hydroxide pastes employed did not effectively eliminate the infection from the RCS and periapical lesions. However, several bacteria seen in the histological sections were probably dead or were inactivated by the biomechanical preparation and calcium hydroxide-based intracanal dressing.  相似文献   

4.
The search for new instruments to promote an appropriate cervical preparation has led to the development of new rotary instruments such as TripleGates. However, to the best of the authors'' knowledge, there is no study evaluating TripleGates effect on the “risk zone” of mandibular molars.

Objectives

: The aim of this study was to evaluate the effects of a crown-down sequence of Gates-Glidden and TripleGates burs on the remaining cervical dentin thickness and the total amount of dentin removed from the root canals during the instrumentation by using cone beam computed tomography. The number of separated instruments was also evaluated.

Material and Methods

: Mesial roots of 40 mandibular first molars were divided into 2 equal groups: crown-down sequence of Gates-Glidden (#3, #2, #1) and TripleGates burs. Cervical dentin thickness and canal area were measured before and after instrumentation by using cone beam computed tomography and image analysis software. Student’s t-test was used to determine significant differences at p<0.05.

Results

: No significant differences (p>0.05) were observed between the instruments, regarding the root canal area and dentin wall thickness.

Conclusion

: Both tested instruments used for cervical preparation were safe to be used in the mesial root canal of mandibular molars.  相似文献   

5.

Objectives:

this study evaluated the apical deviation of curved root canals instrumented with K3 and ProTaper systems.

Material and methods:

twenty root canals of human maxillary and mandibular first molars were employed, which were divided into 2 groups: group A (10 teeth) was instrumented with the K3 system, and group B (10 teeth) with the ProTaper system. Evaluation of deviation was performed by double radiographic exposure. Radiographs were achieved before and after instrumentation, with 0.3-second, thus allowing superimposition of images. Three-dimensional computerized tomograph was performed in 3 specimens in each group, as an additional means to evaluate the apical deviation.

Results:

were evaluated by the parametric test Student-Newman-Keuls at 5%, which did not reveal significance between groups concerning the apical deviation. The results of computerized tomograph images demonstrated that the larger deviation of the root canal occurred at the distolingual area for both systems.

Conclusions:

both techniques produced a mild apical deviation. Computerized microtomography was shown to be accurate for experimental endodontics studies.  相似文献   

6.
AIM: To compare the cleaning effectiveness and shaping ability of Mtwo, K3, and RaCe nickel-titanium rotary instruments during the preparation of curved root canals in extracted human teeth. METHODOLOGY: A total of 60 root canals of mandibular and maxillary molars with curvatures ranging between 25 degrees and 35 degrees were divided into three groups of 20 canals. Based on radiographs taken prior to instrumentation with the initial instrument inserted into the canal, the groups were balanced with respect to the angle and the radius of canal curvature. Canals were prepared using a low-torque control motor. Using pre- and post-instrumentation radiographs, straightening of the canal curvatures was determined with a computer image analysis program. The amount of debris and smear layer was quantified on the basis of a numerical evaluation scale. The data established for scoring the debris and the smear layer was separately recorded and analysed statistically using the Kruskal-Wallis test. RESULTS: During preparation no instrument separated. Completely clean root canals were never observed. For debris removal Mtwo instruments achieved significantly better results (P < 0.001) than K3 and RaCe instruments. The results for remaining smear layer were similar and not significantly different (P > 0.05). Mtwo instruments maintained the original canal curvature significantly better (P < 0.05) than the other instruments. Instrumentation with Mtwo files was significantly faster than with K3 or RaCe instruments (P < 0.05). CONCLUSIONS: Under the conditions of this study, Mtwo instruments resulted in good cleaning and maintained the original curvature significantly better than K3 or RaCe files.  相似文献   

7.

Introduction

Reports comparing clinical outcomes using nickel-titanium (NiTi) reciprocating instruments with other instrumentation modalities are scarce. This study examined initial shaping outcomes after an instrumentation change of root canal instrumentation technique in a doctor of dental surgery educational program. Student characteristics, faculty/student ratio, facility, and overall endodontic treatment guidelines remained unchanged.

Methods

A total of 200 nonsurgical initial molar root canal treatments completed by third-year dental students were evaluated. The cases were examined regarding the number of treatment appointments, access cavity preparation, canal taper, canal transportation, perforations, missed canals, presence of ledges, fractured instruments, obturation length, obturation quality, and sealer extrusion. Two independent evaluators determined the number of appointments per case; 4 independent and blinded evaluators analyzed radiographs at 4 treatment stages: preoperative situation, working length, cone fit, and obturation.

Results

The following factors were significantly different between the 2 cohorts: the number of appointments, preparation length, taper, and occurrence of ledges. The WaveOne (Dentsply Sirona, York, PA) cohort had a significantly reduced treatment time compared with hand/GT rotary instrumentation (Dentsply Tulsa Dental, Tulsa, OK) (average of 3.3 vs 4.3 appointments). Appropriate length control and adequate taper were significantly more frequent in the WaveOne group. The frequency of ledges was significantly larger in the hybrid group. Other variables, such as access cavity preparation, canal transportation, perforations, missed canals, fractured instruments, obturation quality, and sealer extrusion, were statistically similar between the 2 groups.

Conclusions

NiTi reciprocation instrumentation was superior to hybrid hand/NiTi rotary instrumentation in reducing both patient appointments and the incidence of ledging and in improving obturation length and taper in a dental student clinic setting.  相似文献   

8.
This study investigated several parameters of root canal preparation with three different rotary NiTi systems: Hero Shaper, ProTaper, and RaCe. The parameters evaluated were: changes in root canal volume and cross-sectional area, canal transportation, and working time. Curved, mesial molar roots were scanned in a computed tomography (CT) unit before and after instrumentation. Cross-sectional views of each canal were obtained at 1 mm intervals. Postinstrumentation volume and cross-sectional area of root canals and the extent of transportation were calculated using image analysis software and, thereafter, subjected to statistical analysis. ProTaper removed significantly more dentin than Hero Shaper (p < 0.05). Instrumentation increased the cross-sectional area at all cutplanes, while the difference between test groups was not significant (p > 0.05). RaCe files significantly transported the canals at the coronal level (p < 0.05). There was no difference between any rotary systems in regards to working time.  相似文献   

9.
Gram-negative bacteria play an essential role in endodontic infections because they have virulence factors such as endotoxin. Due to its potential cytotoxic activity, special attention has been given to the removal/neutralization of this endotoxin in the root canal system.

Objective

The aim of this study was to evaluate the influence of the apical enlargement size (AES) by using rotary instruments on the endotoxin level reduction of dental root canals.

Material and Methods

Forty root canals of the mandibular premolar teeth were used. Escherichia coli endotoxin (055: B55) was inoculated into thirty root canals. Ten teeth served as the negative control group. After the incubation period, the first endotoxin samples were collected from the root canals with a sterile/apyrogenic paper point for the analysis of the endotoxin units (EU/mL) present before instrumentation (S1). Specimen instrumentation was performed with the Mtwo® rotary system in the sequence 10/.04, 15/.05, 20/.06, 25/.06, 30/.05, 35/.04 and 40/.04. To monitor the effectiveness of increasing apical enlargement on endotoxin removal, the second endotoxin samples were collected from all the root canals after instrumentation with the following instruments: #25/.06- (S2); #30/.05- (S3); # 35/.04- (S4); and #40/.04- (S5). Limulus amebocyte lysate (LAL) was used to quantify the levels of endotoxin. The results were statistically compared by using repeated measures of ANOVA with post hoc Tukey testing.

Results

Increasing levels of endotoxin removal was achieved by large sized apical enlargement: S2 (AES #25/.06)- 89.2%, S3 (AES #30/.05)- 95.9%, S4 (AES #35/.04)- 97.8% and S5 (AES #40/.04)- 98.2%. Substantial reduction of endotoxin content was obtained in S4 and S5 compared to S2 (p<0.05), however, the root canal preparation was not able to eliminate the endotoxin.

Conclusions

Under the conditions of this study, it was concluded that the reduction of endotoxin levels of the dental root canals could be predicted by increasing the apical enlargement size.  相似文献   

10.

Objective:

This study evaluated whether smear layer removal has any influence on the filling of the root canal system, by examining the obturation of lateral canals, secondary canals and apical deltas.

Material and Methods:

Eighty maxillary and mandibular canines were randomly divided into two groups, according to their irrigation regimen. Both groups were irrigated with 1% NaOCl during canal shaping, but only the teeth in Group II received a final irrigation with 17% EDTA for smear layer removal. The root canals were obturated with lateral condensation of gutta-percha and the specimens were cleared, allowing for observation under the microscope.

Results:

In Groups I and II, 42.5% and 37.5% of the teeth, respectively, presented at least one filled canal ramification. Although a larger number of obturated ramifications was found in Group I, there were no statistically significant differences between the two groups (p = 0.4957).

Conclusion:

Smear layer removal under the conditions tested in this study did not affect the obturation of root canal ramifications when lateral condensation of gutta-percha was the technique used for root canal filling.  相似文献   

11.

Objective:

This study evaluated the wear in the apical third of simulate canals after preparation with ProTaper Universal Rotary System.

Material and Methods:

24 sets of instruments were used in 24 simulated canals in transparent epoxy resin blocks with degree of curvature of either 20°or 40°. The canals were photographed preoperatively and after preparation of the apical stop with ProTaper F3, F4 and F5 instruments. The initial and final images were exported to Adobe Photoshop® software and superimposed to detect the root canal wall differences (in mm) between them, in two points located 1 (A) and 5 (B) mm from the point where the working length was established. Data were subjected to analysis of variance to verify the existence of interaction among the factors: canal curvature, instrument size and curve location. Significant level was set at 5%.

Results:

Regardless of the location and the canal curvature, F4 and F5 instruments produced the greatest wear (p<0.05).

Conclusions:

There was a deviation from the original pathway towards the outside of the root curvature in both analyzed points. All instruments produced canal transportation, but the F4 and F5 instruments produced more than the other instruments, and should thus be used with care in curved canals.  相似文献   

12.
AIM: To determine the cleaning effectiveness and shaping ability of ProTaper and RaCe nickel-titanium rotary instruments during the preparation of curved root canals in extracted human teeth. METHODOLOGY: A total of 48 root canals of mandibular and maxillary molars with curvatures ranging between 25 degrees and 35 degrees were divided into two groups of 24 canals each. Based on radiographs taken prior to instrumentation with the initial instrument inserted into the canal, the groups were balanced with respect to the angle and the radius of canal curvature. Canals were prepared using a crown-down preparation technique. After each instrument, the root canals were flushed with a 2.5% NaOCl solution and at the end of instrumentation with NaCl. Using pre- and post-instrumentation radiographs, straightening of the canal curvatures was determined with a computer image analysis program. After splitting the roots longitudinally, the amount of debris and smear layer was quantified on the basis of a numerical evaluation scale, using a scanning electron microscope (SEM). The data established for scoring the debris and the smear layer were separately recorded and analysed statistically using the Wilcoxon test. RESULTS: Two ProTaper and three RaCe instruments fractured; there was no significant difference between instrument types (P > 0.05). Completely clean root canals were never observed. For debris removal, RaCe files achieved significantly better results (P < 0.001) than ProTaper instruments. The results for remaining smear layer were similar and not significantly different (P > 0.05). RaCe instruments maintained the original canal curvature significantly better (P < 0.05) than ProTaper instruments. No significant differences were detected between the instruments (P > 0.05) for the time taken to prepare the canals. CONCLUSIONS: Under the conditions of this study, RaCe instruments resulted in relatively good cleaning and maintained the original curvature significantly better than ProTaper did.  相似文献   

13.

Objectives:

The aim of this study was to determine the effect of Er:YAG laser irradiation used to clean dentinal walls on the apical sealing of root canals filled with different types of sealers.

Background Data:

Laser application to the dentinal walls removed debris, rendering the root canals free of smear layers and leaving the dentinal canaliculi open.

Methods:

Sixty-four maxillary canines obtained from laboratory files were instrumented with K-files (Dentsply, Maillefer, Ballaigues, Switzerland) using the crown-down technique, and irrigated with a 0.5% sodium hypochlorite solution. The specimens were divided into two groups of 32 teeth each. In group I, the teeth were instrumented and irrigated with sodium hypochlorite solution, and divided into four subgroups to be sealed with the different materials (Endofill, N-Rickert, Sealapex and Sealer 26). In group II, the root canals were subjected to Er:YAG laser irradiation (200 mJ, 7 Hz and 60 J total energy), followed by root canal sealing as in group I.

Results:

The data showed lower levels of apical microleakage in the teeth filled with N-Rickert, Sealapex and Sealer 26 cements than in those sealed with Endofill (p < 0.01). No significant difference in microleakage was observed between teeth irrigated only with 0.5% sodium hypochlorite and those submitted to Er:YAG laser application (p > 0.05).

Conclusions:

The Er:YAG laser irradiation applied to the root canal walls was not able to prevent apical microleakage.  相似文献   

14.

Objectives:

to compare the apical sealing ability of four root canal sealers. Materials and methods: forty extracted human maxillary canines were instrumented 1 mm short of the anatomical apex and randomly assigned to four groups (n=10), according to the root canal sealer used for obturation: Endofill, AH Plus, EndoREZ and Epiphany. Root canals were obturated with guttapercha points, except for the Epiphany group, in which resin points (Resilon) were used. The teeth were immersed in India ink for seven days and clarified using methyl salicylate. The extent of apical dye penetration was measured with a measuroscope in all aspects of the canal.

Results:

AH Plus (0.02 mm ± 0.07), Epiphany (0.00 mm ± 0.00) and EndoREZ (0.32 mm ± 0.62) did not differ statistically to each other (p>0.01). EndoFill presented the highest dye penetration mean (0.83 mm ± 0.73) and was statistically different from the other sealers (p<0.01).

Conclusions:

the resin-based root canal sealers presented lesser apical microleakage than the zinc oxide and eugenol based sealer. No statistical differences were observed among resin based sealers.  相似文献   

15.

Objective

To evaluate the impact of the type of root canal preparation, intraradicular post and mechanical cycling on the fracture strength of roots.

Material and Methods

eighty human single rooted teeth were divided into 8 groups according to the instruments used for root canal preparation (manual or rotary instruments), the type of intraradicular post (fiber posts- FRC and cast post and core- CPC) and the use of mechanical cycling (MC) as follows: Manual and FRC; Manual, FRC and MC; Manual and CPC; Manual, CPC and MC; Rotary and FRC; Rotary, FRC and MC; Rotary and CPC; Rotary, CPC and MC. The filling was performed by lateral compactation. All root canals were prepared for a post with a 10 mm length, using the custom #2 bur of the glass fiber post system. For mechanical cycling, the protocol was applied as follows: an angle of incidence of 45°, 37°C, 88 N, 4 Hz, 2 million pulses. All groups were submitted to fracture strength test in a 45° device with 1 mm/ min cross-head speed until failure occurred.

Results

The 3-way ANOVA showed that the root canal preparation strategy (p<0.03) and post type (p<0.0001) affected the fracture strength results, while mechanical cycling (p=0.29) did not.

Conclusion

The root canal preparation strategy only influenced the root fracture strength when restoring with a fiber post and mechanical cycling, so it does not seem to be an important factor in this scenario.  相似文献   

16.

Objective

The aim of this study was to evaluate the in vitro action of ProTaper retreatment files and ProTaper Universal in the retreatment of mandibular premolars.

Material and methods

The amount of debris extruded apically was measured and the time to reach the working length and to complete the removal of gutta-percha was observed. Thirty teeth had their canals prepared using ProTaper Universal files and were obturated by the single cone technique. The teeth were then stored at 37ºC in a humid environment for 7 days. During the use of the rotary instruments for root canal filling removal, the apical portions of the teeth were attached to the open end of a resin tube to collect the apically extruded debris.

Results

ProTaper Universal files were significantly faster (p=0.0011) than the ProTaper retreatment files to perform gutta-percha removal, but no significant difference was found between the files regarding the time to reach the working length or the amount of apical extrusion.

Conclusions

ProTaper Universal rotary had better results for endodontic retreatment, and both techniques promote similar apical extrusion of debris.  相似文献   

17.
AIM: To evaluate the relative performance of Endo-Eze Anatomic Endodontic Technology (AET) stainless steel instruments when shaping maxillary molar root canals in vitro. Methodology Extracted human maxillary molars were scanned, before and after root canal shaping with Endo-Eze AET, employing micro-computed tomography (muCT) at an isotropic resolution of 34 microm. Three-dimensional root canal models were reconstructed and evaluated for volume, surface area, 'thickness' (diameter), canal transportation and prepared surface. Preparation errors such as apical zips, perforations and fractured instruments were visually determined from those models. Means were contrasted using anova and Scheffé post-hoc tests. RESULTS: Volume and surface area increased significantly and similarly in mesiobuccal (mb), distobuccal (db) and palatal (p) canals and gross preparation errors (n = 17) were found. Mean root canal diameters, 5 mm coronal to the apex, increased from 0.31 to 0.52, 0.35 to 0.50 and 0.50 to 0.70 mm for mb, db and p canals, respectively. Mean canal transportation ranged from 0.15 to 0.29, 0.15 to 0.27 and 0.21 to 0.33 mm for apical, middle and coronal root canal levels, respectively, with highest values found for mb canals (P < 0.003). Root canals were significantly straightened during preparation (P < 0.002). CONCLUSIONS: In summary, Endo-Eze AET instruments shaped root canals in maxillary molars with substantial canal transportation, particularly in mesiobuccal root canals. Preparation with this instrument removed high volumes of dentine, even though apical preparation was size 30. Based on the current results, Endo-Eze AET cannot be recommended for the preparation of teeth with curved root canals.  相似文献   

18.

Objective:

The aim of this study was to examine the instrumented walls of root canals prepared with the ProTaper Universal™ rotary system.

Material and Methods:

Twenty mesiobuccal canals of human first mandibular molars were divided into 2 groups of 10 specimens each and embedded in a muffle system. The root canals were transversely sectioned 3 mm short of the apex before preparation and remounted in their molds. All root canals were prepared with ProTaper Universal™ rotary system or with Nitiflex™ files. The pre and postoperative images of the apical thirds viewed with a stereoscopic magnifier (×45) were captured digitally for further analysis. Data were analyzed statistically by Fisher''s exact test and Chi-square test at 5% significance level.

Results:

The differences observed between the instrumented and the noninstrumented walls were not statistically significant (p<0.05).

Conclusions:

The Nitiflex™ files and the ProTaper Universal™ rotary system failed to instrument all the root canal walls.  相似文献   

19.

Objective

The aim of this study was to investigate the ability of two NiTi rotary apical preparation techniques used with an electronic apex locator-integrated endodontic motor and a manual technique to create an apical stop at a predetermined level (0.5 mm short of the apical foramen) in teeth with disrupted apical constriction, and to evaluate microleakage following obturation in such prepared teeth.

Material and Methods:

85 intact human mandibular permanent incisors with single root canal were accessed and the apical constriction was disrupted using a #25 K-file. The teeth were embedded in alginate and instrumented to #40 using rotary Lightspeed or S-Apex techniques or stainless-steel K-files. Distance between the apical foramen and the created apical stop was measured to an accuracy of 0.01 mm. In another set of instrumented teeth, root canals were obturated using gutta-percha and sealer, and leakage was tested at 1 week and 3 months using a fluid filtration device.

Results

All techniques performed slightly short of the predetermined level. Closest preparation to the predetermined level was with the manual technique and the farthest was with S-Apex. A significant difference was found between the performances of these two techniques (p<0.05). Lightspeed ranked in between. Leakage was similar for all techniques at either period. However, all groups leaked significantly more at 3 months compared to 1 week (p<0.05).

Conclusions

Despite statistically significant differences found among the techniques, deviations from the predetermined level were small and clinically acceptable for all techniques. Leakage following obturation was comparable in all groups.  相似文献   

20.
Aim  To investigate instrumentation time, working safety and the shaping ability of two rotary nickel–titanium (NiTi) systems (Alpha System and ProTaper Universal) in comparison to stainless steel hand instruments.
Methodology  A total of 45 mesial root canals of extracted human mandibular molars were selected. On the basis of the degree of curvature the matched teeth were allocated randomly into three groups of 15 teeth each. In group 1 root canals were prepared to size 30 using a standardized manual preparation technique; in group 2 and 3 rotary NiTi instruments were used following the manufacturers' instructions. Instrumentation time and procedural errors were recorded. With the aid of pre- and postoperative radiographs, apical straightening of the canal curvature was determined. Photographs of the coronal, middle and apical cross-sections of the pre- and postoperative canals were taken, and superimposed using a standard software. Based on these composite images the portion of uninstrumented canal walls was evaluated.
Results  Active instrumentation time of the Alpha System was significantly reduced compared with ProTaper Universal and hand instrumentation ( P  <   0.05; anova ). No instrument fractures occurred in any of the groups. The Alpha System revealed significantly less apical straightening compared with the other instruments ( P  <   0.05; Mann–Whitney U test). In the apical cross-sections Alpha System resulted in significantly less uninstrumented canal walls compared with stainless steel files ( P  <   0.05; chi-squared test).
Conclusion  Despite the demonstrated differences between the systems, an apical straightening effect could not be prevented; areas of uninstrumented root canal wall were left in all regions using the various systems.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号