首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
PURPOSE: To compare the measurements of intraocular pressure (IOP) with dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT) in eyes with corneal graft and to evaluate the influence of corneal thickness (CCT), corneal curvature (CC), and astigmatism on these methods. DESIGN: Prospective, observational cross-sectional study. METHODS: Eighteen eyes of 18 patients after penetrating keratoplasty (PKP) and 14 eyes of 14 patients after deep lamellar keratoplasty (DLKP) underwent IOP evaluation with DCT and GAT, and measurements of CCT, CC, and astigmatism. Bland-Altman plots were used to evaluate the agreement between tonometers. Multivariate regression analysis was used to evaluate the influence of ocular structural factors and running suture on IOP measurements obtained with both tonometers. RESULTS: IOP values obtained by DCT and GAT were strongly correlated in all eyes (r = .91; P < .001). DCT values measured 2.5 +/- 1.7 mm Hg higher than GAT readings (P < .001). A reduction of the mean IOP difference between DCT and GAT with an increase in IOP values (P < .001) was found. Regression analysis showed no effect of CCT, CC, astigmatism, and running suture on both DCT and GAT readings, either in DLKP or in PKP eyes. CONCLUSIONS: We found a good overall correlation between both tonometers but the agreement between instruments differs in high or low IOP ranges. The wide and varying 95% limits of agreement between DCT and GAT indicates that DCT provides IOP measurements on deep lamellar and penetrating keratoplasties which can be used in the clinical practice.  相似文献   

2.
Purpose: To compare intraocular pressure (IOP) readings taken using dynamic contour tonometry (DCT) with IOP readings taken with Goldmann applanation tonometry (GAT) in eyes with glaucoma or ocular hypertension. Methods: The present study included 100 eyes in 100 patients with glaucoma or ocular hypertension. After pachymetry DCT and GAT were performed. Intraocular pressures as measured with DCT and GAT were compared with one another and with central corneal thickness (CCT). Results: Mean DCT IOP measurements (20.1 ± 4.3 mmHg) were significantly (p < 0.001) higher than GAT IOP values (17.9 ± 4.7 mmHg). The mean difference between DCT and GAT measurements was 2.1 mmHg (range ? 3.4 to 9.7 mmHg). The difference followed a normal distribution. Measurements made with DCT and GAT correlated significantly with one another (Spearman’s rho = 0.761, p < 0.001). Neither GAT nor DCT measurements showed a significant correlation with CCT (537 ± 39 μm, range 458–656 μm). Multivariate regression analysis has shown that the difference between DCT and GAT is influenced significantly by ocular pulse amplitude (r = ? 0.334, p = 0.001) and it is not influenced by CCT (r = ? 0.106, p = 0.292). Conclusions: In eyes with glaucoma or ocular hypertension, DCT facilitates suitable and reliable IOP measurements which are in good concordance with GAT readings. Variation in CCT cannot by itself explain the differences in measurements taken with DCT and GAT in a number of eyes.  相似文献   

3.
Background Various sources of error, including central corneal thickness (CCT) and structural corneal rigidity, have been proposed for Goldmann applanation tonometry (GAT). The Pascal dynamic contour tonometer (DCT) is a novel device designed for intraocular pressure (IOP) measurements assumed to be largely independent of CCT and corneal curvature. We compared DCT with GAT in eyes with normal corneas of various thickness.Methods We prospectively measured IOP using DCT and GAT in random order in 100 eyes of 100 subjects (M:F=46:54; mean age 42±19, range 23–88 years).Results Mean DCT values were about 1mmHg higher than GAT readings (16±3 vs 15±3 mmHg, p=0.001). Bland–Altman analysis of individual pairs of DCT and GAT measurements revealed a bias of –1.0 mmHg [95% confidence interval (CI): ±1.2]. Neither GAT nor DCT showed a significant correlation with CCT (533±48, range 399–641 m).Conclusions In eyes with normal corneas, DCT allows suitable and reliable IOP measurements which are in good concordance with GAT. Comparison of DCT with intracameral manometry is desirable in the future.  相似文献   

4.
AIMS: To establish the effects of central corneal thickness (CCT) on intraocular pressure (IOP) measured with a prototype Pascal dynamic contour tonometer (DCT), to evaluate the effect of CCT and age on the agreement between IOP measured with the Pascal DCT and Goldmann applanation tonometer (GAT), and to compare the interobserver and intraobserver variation of the DCT with the GAT. METHODS: GAT and DCT IOP measurements were made on 130 eyes of 130 patients and agreement was assessed by means of Bland-Altman plots. The effect of CCT and age on GAT/DCT IOP differences was assessed by linear regression analysis. Interobserver and intraobserver variations for GAT and DCT were assessed in 100 eyes of 100 patients. RESULTS: The mean difference (95% limits of agreement) between GAT and DCT was -0.7 (-6.3 to 4.9) mm Hg. GAT/DCT IOP differences increased with thicker CCT (slope 0.017 mm Hg/microm, 95% CI 0.004 to 0.03, r2 = 0.05, p = 0.01), and with greater age, slope 0.05 mm Hg/year (95% CI 0.012 to 0.084, r2 = 0.05, p = 0.01). The intraobserver variability of GAT and DCT was 1.7 mm Hg and 3.2 mm Hg, respectively. The interobserver variability was (mean difference (95% limits of agreement)) 0.4 (-3.5 to 4.2) mm Hg for GAT and 0.2 (-4.9 to 5.3) mm Hg for DCT. CONCLUSIONS: GAT is significantly more affected than DCT by both CCT and subject age. The effect of age suggests an age related corneal biomechanical change that may induce measurement error additional to that of CCT. The prototype DCT has greater measurement variability than the GAT.  相似文献   

5.
PURPOSE: To compare dynamic contour tonometry with Goldmann applanation tonometry in structurally normal corneas over a wide range of central corneal thickness (CCT). PATIENTS AND METHODS: Twenty-five patients each with normal CCT (group A), thin corneas (group B), and thick corneas (group C) had IOP measured with the Goldmann (GAT) and dynamic contour tonometer (DCT). RESULTS: In group A (mean CCT = 552 +/- 16 microm) the mean GAT was 15.9 +/- 3.1 mm Hg and mean DCT was 16 +/- 3.3 mm Hg (P = 0.91). In group B (mean CCT = 491 +/- 19 microm) the mean GAT was 13.2 +/- 3.5 mm Hg and the mean DCT was 15.9 +/- 3.5 mm Hg (P = 0.009). For group C (mean CCT = 615 +/- 22 microm), the mean GAT was 17.4 +/- 3.8 mm Hg and the mean DCT was 17.4 +/- 3.5 mm Hg (P = 0.95). The 95% agreement limits for DCT were -3.1 mm Hg to 2.9 mm Hg. The mean GAT-DCT difference was -2.6 mm Hg in thin corneas and -0.06 mm Hg in thick corneas. Below 520 microm reduction of 10 microm in CCT appears to result in a significant underestimation of the GAT IOP by 0.7 mm Hg (P < .001) and above 580 microm a non-significant overestimation of 0.2 mm Hg per 10 microm increase in CCT (P = 0.27). CONCLUSION: Dynamic contour tonometer agrees well on average with GAT but the agreement limits are wide. In structurally normal thin corneas DCT may give a more accurate assessment of the true IOP but it does not appear to have any benefit over GAT in thick corneas.  相似文献   

6.
Purpose: To investigate the effects of central corneal thickness (CCT) on intraocular pressure (IOP) measurements of the Pascal dynamic contour tonometry (DCT), Canon TX‐10 non‐contact tonometry (NCT) and Goldmann applanation tonometry measurements (GAT) in healthy subjects. Methods: IOP values of 135 eyes with normal corneas of 135 healthy volunteers were determined by DCT, NCT and by GAT. The CCT was measured using an ultrasonic pachymeter after all IOP determinations had been made. Results: When DCT measurements were compared (IOP = 17.52 ± 2.0 mmHg) with NCT measurements (IOP = 16.54 ± 2.77 mmHg) and GAT measurements (IOP = 15.07 ± 2.35 mmHg), DCT measurements were significantly higher than NCT and GAT (p < 0.001). There was a significant correlation between CCT with both NCT (r = 0.260, p = 0.003) and GAT measurements (r = 0.257, p = 0.005). There was a weak correlation that was not statistically significant between CCT and DCT (r = 0.160, p = 0.079). Conclusion: The IOP measurements with DCT seem to be less dependent on CCT. NCT appears to be more affected by variation in CCT than GAT.  相似文献   

7.
PURPOSE: To compare intraocular pressure (IOP) measurements taken with Pascal dynamic contour tonometry (DCT), the TonoPen and the Goldmann applanation tonometry (GAT). The influence of central corneal thickness (CCT) on IOP measurements taken with Pascal DCT and the TonoPen was evaluated. METHODS: One eye in each of 101 consecutive patients with primary open-angle glaucoma (POAG) underwent ultrasonic CCT measurement and IOP evaluation with GAT, Pascal DCT and the TonoPen in random order. The agreement between results from Pascal DCT and the TonoPen and those of GAT was assessed using the Bland-Altman method. The deviation of Pascal DCT and TonoPen readings from GAT values, corrected for CCT, was calculated and correlated to CCT using a linear regression model. RESULTS: The mean of the differences in IOP measurements was 3.2 +/- 2.4 mmHg for Pascal DCT minus GAT readings and 0.5 +/- 4.5 mmHg for TonoPen minus GAT readings. The 95% confidence interval of differences in IOP measurements was higher between TonoPen and GAT readings (- 6 to 7 mmHg) than between Pascal and GAT readings (0.1-6.8 mmHg). Pascal DCT significantly overestimated IOP compared with GAT, especially for higher IOP readings. Bland-Altman scatterplots showed reasonable inter-method agreement between Pascal DCT and GAT measurements, and poor agreement between TonoPen and GAT measurements. The deviations of Pascal DCT and TonoPen readings from the corrected GAT values were both highly correlated with CCT values (linear regression analysis, p < 0.0001). The mean change in measured IOP for a 10-microm increase in CCT was 0.48 mmHg for Pascal DCT and 0.74 mmHg for the TonoPen. CONCLUSIONS: Agreement with GAT measurements was higher for Pascal DCT than for TonoPen readings; however, Pascal DCT significantly overestimated IOP values compared with GAT. Measurements of IOP obtained with both Pascal DCT and the TonoPen appeared to be influenced by CCT, and this influence appeared to be greater for the latter.  相似文献   

8.
AIM: To compare the intraocular pressure (IOP) measurements obtained with the rebound tonometry (RT), dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT) in normal and glaucomatous eyes and investigate the effects of central corneal thickness (CCT) and corneal curvature (CC) on IOP measurements. METHODS: One hundred and twenty-four eyes of 124 subjects were enrolled in this cross-sectional study. Fifty-six of participants were healthy individuals and 68 of them were glaucomatous patients. IOP was measured on each subject always in the same order, ICare RT-Pascal DCT-GAT, after a minimum interval of 10min between measurements. CCT and CC were measured using a rotating Scheimpflug camera before the IOP measurements in all subjects. One way repeated measures ANOVA, Pearson correlation coefficient and regression analysis, and Bland-Altman analysis was used for the statistical assessment. RESULTS: Mean IOP for all enrolled eyes was 16.00±3.80 mm Hg for GAT, 16.99±4.91 mm Hg for RT, and 20.40±4.44 mm Hg for DCT. Mean differences between GAT and RT was -1.75±3.41 mm Hg in normal (P<0.001) and -0.37±3.00 mm Hg in glaucomatous eyes (P=0.563). Mean differences between GAT and DCT was -4.06±3.42 mm Hg in normal (P<0.001) and -4.67±3.12 mm Hg in glaucomatous eyes (P<0.001). GAT and RT were significantly positive correlated with CCT in normal (r=0.317, P=0.017 and r=0.576, P<0.001, respectively) and glaucomatous eyes (r=0.290, P=0.016 and r=0.351, P=0.003, respectively). DCT was also significantly positive correlated with CCT in normal eyes (r=0.424, P=0.001) but not in glaucomatous eyes (r=0.170, P=0.165). All tonometers were unaffected by CC. CONCLUSION: IOP measurements by RT and DCT were significantly higher than GAT. DCT has highest IOP measurements among these tonometers. RT was most influenced tonometer from CCT although all tonometers were significantly positive correlated with CCT except DCT in glaucomatous eyes. CC did not influence IOP measurements.  相似文献   

9.
PURPOSE: Dynamic contour tonometry (DCT) is a new technique to measure intraocular pressure (IOP). In several studies no correlation between IOP values and corneal thickness was shown with DCT. This is in contrast to the gold standard, Goldmann applanation tonometry (GAT). The authors evaluated the reproducibility (RP) of DCT compared to GAT, a prerequisite for its introduction into clinical routine. METHODS: IOP was measured with both DCT and GAT in 50 subjects with normal cornea. To evaluate the short-term RP, four DCT and four GAT measurements were performed at day 1 in a randomized order. Long-term RP was determined by one additional measurement per method at day 2, 5, and 8. RESULTS: The short-term RP was defined as the mean value of all standard deviations (SD) of the individual measurements at day 1. Short-term RP was 1.1 mmHg for GAT and 1.2 mmHg for DCT. For long-term reproducibility, mean SD was 1.2 mmHg for GAT and 1.5 mmHg for DCT. Bland-Altman revealed a good agreement of the two methods. However, mean DCT values were on average 0.8+/-1.1 mmHg higher than GAT values. A significant correlation was observed between GAT and CCT (r2=0.15, p=0.006), but not between DCT and CCT (r2=0.032, p=0.21). CONCLUSIONS: Short- and long-term reproducibility of DCT is comparable to that of GAT. GAT is more affected by CCT than DCT, measuring higher IOPs in eyes with higher central corneal thickness.  相似文献   

10.
Background In an experimental laboratory investigation we compared intraocular pressure (IOP) measurements obtained by dynamic contour tonometry (DCT), Goldmann applanation tonometry (GAT), and pneumatonometry (PTG) with intracameral manometry on human cadaver corneas of different hydration conditions.Methods Ten freshly enucleated eyes were de-epithelialized. Two tubes were placed in the anterior chamber in opposite directions and connected to a transducer and to a bottle system filled with balanced salt solution. The pressure in the eye was then adjusted between 5 mmHg and 58 mmHg by electronically altering the height of the bottle. Central corneal thickness (CCT) was registered and IOP measurements were obtained with DCT, GAT, and PTG at each manometric pressure reading. Immediately after the trial the same corneas were artificially dehydrated and the same measurement regimen was repeated.Results In the pressure range defined by the bottle height 10–50 cm, IOP values measured by DCT were 0.50 mmHg (95% CI=0.40–0.60) and 0.36 mmHg (95% CI=0.25–0.47) higher than manometric readings before and after dehydration, respectively. GAT showed consistently lower values than manometry, the difference being –3.48 mmHg (95% CI=–3.91 to –3.05) and –3.14 mmHg (95% CI=–3.39 to –2.89), respectively. Similar results were obtained with PGT, namely differences of –4.75 mmHg (95% CI=–5.21 to –4.29) and –3.98 mmHg (95% CI=–4.48 to –3.48) for the hydrated and the dehydrated corneal condition, respectively. Only DCT showed no significant change in accuracy between hydrated and dehydrated corneas.Conclusions In this in vitro study DCT values for IOP were significantly closer to the manometric reference pressure than those obtained using GAT and PTG, independent of the state of corneal hydration.  相似文献   

11.
目的探讨在不同的中央角膜厚度(CCT)下PASCAL动态轮廓眼压计(DCT)与Goldmann压平眼压计(GAT)眼压(IOP)测量值的相关性,评价两者测量值的一致性及临床上两种眼压计测量值相互替换的可能性。方法非青光眼病例87例(168只眼)分别用DCT和GAT进行眼压测量,两种仪器的测量顺序随机。同时,用NIDEK UP-1000型角膜测厚仪测量CCT。DCT与GAT眼压测量值的相关性采用Spearson双变量相关分析,Bland-Altman分析法评价两种仪器IOP测量值的一致性。结果 (1)在不同的角膜厚度下DCT与GAT测得的IOP值均显著相关(CCT≤520μm,n=24,r=0.67,P<0.001;520μm580μm,n=44,r=0.61,P<0.001)。(2)DCT眼压测量值与CCT不相关(r=0.14,P=0.08),GAT眼压测量值与CCT显著相关(r=0.59,P<0.001)。(3)Bland-Altman一致性分析显示两种仪器的差值的均值为-0.9mm Hg,一致性界限为(-5.6 mm Hg,3.9 mm Hg)。结论 (1)在不同的角膜厚度下DCT与GAT的眼压测量值均显著相关。(2)DCT眼压测量值与CCT值不相关,GAT眼压测量值与CCT值显著相关。(3)一致性分析显示两者测量值的一致性界限跨度较宽,二者的IOP值不可简单地相互代替。  相似文献   

12.
AIM: To determine the effects of peripheral corneal thickness (PCT) on dynamic contour tonometry(DCT) and Goldmann applanation tonometry (GAT). METHODS: A cross-sectional study. We created a software which calculates the corneal contour (CC) as a function of the radius from the corneal apex to each pixel of the contour. The software generates a central circumference with a radius of 1 mm and the remainder of the cornea is segmented in 5 rings concentric with corneal apex being its diameter not constant around the corneal circumference as a consequence of the irregular CC but keeping constant the diameter of each ring in each direction of the contour. PCT was determined as the mean thickness of the most eccentric ring. Locally weighted scatterplot smoothing (LOWESS) regression was used to determine the pattern of the relationship between PCT and both DCT and GAT respectively. Thereafter, two multivariable linear regression models were constructed. In each of them, the dependant variable was intraocular pressure (IOP) as determined using GAT and DCT respectively. In both of the models the predictive variable was PCT though LOWESS regression pattern was used to model the relationship between the dependant variables and the predictor one. Age and sex were also introduced control variables along with their first-degree interactions with PCT. Main outcome measures include amount of IOP variation explained through regression models (R2) and regression coefficients (B). RESULTS: Subjects included 109 eyes of 109 healthy individuals. LOWESS regression suggested that a 2nd-degree polynomial would be suitable to model the relationship between both DCT and GAT with PCT. Hence PCT was introduced in both models as a linear and quadratic term. Neither age nor sex nor interactions were statistically significant in both models. For GAT model, R2 was 17.14% (F=9.02; P=0.0002), PCT linear term B was -1.163 (95% CI: -1.163, -0.617). PCT quadratic term B was 0.00081 (95% CI: 0.00043, 0.00118). For DCT model R2 was 14.28% (F=9.29; P=0.0002), PCT linear term B was -0.712 (95% CI: -1.052, -0.372), PCT quadratic term was B=0.0005 (95% CI: 0.0003, 0.0007). CONCLUSION: DCT and GAT measurements are conditioned by PCT though this effect, rather than linear, follows a 2nd-degree polynomial pattern.  相似文献   

13.
PURPOSE: The effect of increased corneal thickness after Descemet stripping endothelial keratoplasty (DSEK) on intraocular pressure (IOP) measurement has not been previously studied. It is uncertain if this increase in corneal thickness would artificially elevate IOP reading by Goldmann tonometry [GAT] (Haag-Streit, Konig, Switzerland). Therefore the effect of DSEK-related thick cornea on IOP measurement was investigated using three different techniques. DESIGN: Prospective cross-sectional study. METHODS: Participants were recruited from a single tertiary referral center. Fifty eyes of 38 patients with successful DSEK at least three months prior to testing were evaluated. At the time of the study, none of the participants had clinically detectable corneal edema. IOP was measured with GAT, pneumatonometry, and dynamic contour tonometry (DCT) in an unmasked randomized sequence. Central corneal thickness (CCT) was measured by ultrasonic pachymetry. RESULTS: Mean CCT was 701 +/- 68 microm. The mean IOP +/- standard deviation (SD) was 15.9 +/- 4.9 mm Hg for GAT, 20.3 +/- 4.5 mm Hg for pneumatonometry, and 19.8 +/- 4.4 mm Hg for DCT. Pneumatonometry and DCT IOP measurements were significant higher than GAT (P < .01). In contrast, the difference between pneumatonometry and DCT readings was not statistically significant (P = .28). The correlations between IOP and corneal thickness were not significant in this cohort (P > .05). CONCLUSIONS: Falsely elevated GAT, as expected in thick corneas, was not demonstrated after DSEK. High IOP reading by GAT therefore should raise suspicion of elevated IOP in DSEK eyes.  相似文献   

14.
目的 评价动态轮廓眼压计(DCT)和Goldmann压平眼压计(GAT)对在准分子激光原位角膜磨镶术(LASIK)手术前后眼压测量值的变化.方法 取71例141只眼近视患者在LASIK术前和术后一周分别进行角膜厚度(CCT)、GAT、DCT测量.结果 ①LASIK手术前后DCT测得值尤显著性差异(P=0.062),GAT测得值有显著性差异(P<0.001),CCT测得值有显著性差异(P<0001).②Bland-Altman分析示LASIK手术前后DCT与GAT两种测量方法均呈现高度一致性.术前DCT测量值高于GAT测量值1.1mmHg,95%可信区间为(-0.6,2.8)mmHg;术后DCT测量值高于GAT测量值8.2mmHg,95%可信区间为(5.3,11.1)mmhg.③△GAT与△CCT呈正相关,△DCT与△CCT无统计相关性.结论 DCT测量值不受LASIK手术切削的影响,更适合于LASIK手术前后眼压的测量.  相似文献   

15.
PURPOSE: To investigate the agreement in the measurement of intraocular pressure (IOP) obtained by dynamic contour tonometry PASCAL (DCT-PASCAL) and Goldmann applanation tonometry (GAT) in glaucoma eyes and healthy eyes with different central corneal thickness (CCT). DESIGN: Prospective cross-sectional study. METHODS: In a randomized order, three consecutive IOP measurements were performed on 197 eyes of 107 subjects by one examiner using both DCT-PASCAL and GAT on all eyes. Furthermore, ultrasonic pachymetry was performed. The Spearman correlation coefficient (r) was determined to compare IOP readings between DCT-PASCAL and GAT. Regression-based Bland and Altman analysis was used to evaluate agreement between the instruments. RESULTS: Mean IOP values obtained by both instruments were significantly correlated in healthy and glaucoma eyes (all healthy eyes [n = 66]: r = 0.8, P < .001, all glaucoma eyes [n = 131]: r = 0.96, P < .001). Neither GAT nor DCT-PASCAL showed a significant correlation with CCT (GAT: all eyes: r = 0.009, P = .9, DCT-PASCAL: all eyes: r = -0.05, P = .5). Bland and Altman analysis revealed the existence of proportional bias. Thus, 95% limits of agreement between the instruments varied with the actual IOP measurement. CONCLUSIONS: DCT-PASCAL and GAT revealed a strong correlation in IOP measurements between glaucoma and healthy eyes. However, the analysis of agreement indicated some discrepancies between the instruments. Measurements with both GAT and DCT-PASCAL were not correlated with central corneal thickness.  相似文献   

16.
BackgroundAccurate intraocular pressure (IOP) measurement is essential in diagnosing and managing glaucoma. Dynamic contour tonometry (DCT) is less dependent on corneal properties, such as thickness, elasticity, and rigidity, than Goldmann applanation tonometry (GAT). This study examined the relationship between GAT and DCT as well as their relationship with corneal properties and ocular pulse amplitude (OPA).MethodsGAT, DCT, OPA, pachymetry, refractive error, and corneal curvature measurements were obtained on 115 healthy volunteers.ResultsParticipants with thicker corneas (≥580 μm) had higher IOP measurements with GAT than DCT (P = 0.005). Those with thinner corneas (≤520 μm) had lower IOP with GAT versus DCT (P = 0.008). GAT and DCT readings did not differ significantly in corneas with average thickness (521 to 579 μm). A clinically significant IOP difference between DCT and GAT was found in 18.2% of subjects. A correlation was found between OPA and both refractive error and IOP (R2 = .343, P < 0.0001). OPA was higher with increased IOP and decreased myopia.ConclusionDCT provides IOP measurements that are less dependent on corneal factors than GAT, aiding in diagnosis and treatment of patients with ocular hypertension and glaucoma. Additional studies are necessary to examine the relationship between OPA, refractive error, and IOP and its possible association with increased incidence of glaucoma in myopic patients.  相似文献   

17.
PURPOSE: To compare the intraocular pressures (IOP) and ocular pulse amplitudes (OPA) in patients with different types of glaucoma, ocular hypertension (OHT), and normal controls (NC) using dynamic contour tonometry (DCT) and the goldmann applanation tonometry (GAT). METHODS: 906 eyes of 501 adult patients in the following five groups were included in this cross-sectional study: primary open angle glaucoma (POAG), normal tension glaucoma (NTG), Pseudoexfoliative Glaucoma (PXG), OHT, and NC. The following tests were performed simultaneously during a single visit: IOP using DCT and GAT; OPA using DCT and central corneal thickness (CCT) using ultrasound pachymetry. Mixed effects regression models were used to compare the DCT and GAT IOP measurements in the five groups; the effect of CCT on IOP and the relationship between OPA and IOP within each group. RESULTS: DCT consistently had higher IOP values than GAT in POAG, PXG, NTG, and controls (p < 0.001) but not in OHT (p = 0.84). DCT IOP did not change while GAT IOP showed a non-significant increase (p = 0.09) with increased corneal thickness in each group. OPA was found to be highest in OHT (3.61 mmHg) and lowest in the control group (2.86 mmHg) and significantly increased with IOP in all groups. CONCLUSIONS: DCT measures an IOP that is significantly higher than GAT IOP in glaucoma and control subjects but not in ocular hypertensives. Furthermore, the DCT may measure an IOP that is independent of the CCT, which may not be true for the GAT, which increases with the CCT. OPA was highest in OHT and may be affected by the IOP.  相似文献   

18.
Comparison of dynamic contour tonometry with goldmann applanation tonometry   总被引:6,自引:0,他引:6  
PURPOSE: The dynamic contour tonometer (DCT; Pascal tonometer) is a novel tonometer designed to measure intraocular pressure (IOP) independent of corneal properties. The purpose of this study was a comparison of the DCT with the Goldmann applanation tonometer (GAT) with respect to mean of IOP readings, the influence of ocular structural factors on IOP readings, and both intra- and interobserver variability, in a large group of healthy subjects. METHODS: In a prospective study of 228 eyes, IOP measurements by GAT and DCT were compared, and the effects of central corneal thickness (CCT), corneal curvature, axial length, and anterior chamber depth were analyzed. To evaluate intra- and interobserver variability, IOP was measured in eight eyes by four observers. RESULTS: There was a high concordance between the IOP readings obtained by DCT and GAT. However, IOP readings were consistently higher with DCT than with GAT (median difference: +1.7 mm Hg, interquartile range [25th-75th percentile] = 0.8-2.7 mm Hg). In contrast to GAT, multivariable regression analysis showed no significant effect of corneal thickness, corneal curvature, astigmatism, anterior chamber depth, and axial length on DCT readings. For repeated measurements the intraobserver variability was 0.65 mm Hg for the DCT and 1.1 mm Hg for the GAT (P = 0.008). Interobserver variability was 0.44 mm Hg for the DCT and 1.28 mm Hg for the GAT (P = 0.017). CONCLUSIONS: IOP measurements by DCT are highly concordant with IOP readings obtained from GAT but do not vary in CCT and have a lower intra- and interobserver variability. DCT seems to be an appropriate method of tonometry for routine clinical use.  相似文献   

19.
BackgroundWith increasing evidence that vascular risk factors play a role in the development of glaucoma, it is critical to be familiar with factors related to intraocular blood flow, such as the ocular pulse amplitude (OPA). This study evaluates OPA and factors related to it in a healthy, Hispanic population.MethodsRefractive error, corneal curvature, Goldmann applanation tonometry (GAT), dynamic contour tonometry (DCT), OPA, axial length, and central corneal thickness (CCT) measurements were obtained on 104 Hispanic subjects recruited from the community.ResultsOPA ranged from 0.7 to 4.7 mmHg (mean, 2.1 ± 0.8 mmHg) and showed a significant correlation with refractive error, axial length, GAT, and DCT (r=0.250, -0.358, 0.460, 0.378; P=0.011, <0.001, <0.001, and <0.001, respectively). Mean intraocular pressure with GAT was 15.6 mmHg. Mean CCT was 541.2 μm. The average refractive error was 0.75 diopters (D) of myopia, with 25% having >1.00 D myopia.ConclusionNormal OPA values have not been studied in Hispanic populations. OPA is thought to provide information regarding ocular blood flow; however, more studies are needed to determine its significance in glaucoma treatment.  相似文献   

20.
PURPOSE: Thinning of the corneal stroma by laser in situ keratomileusis (LASIK) results in inaccurate low intraocular pressure (IOP) readings by Goldmann applanation tonometry (GAT). Dynamic contour tonometry (DCT) is a novel measuring technique, designed to measure IOP largely independent of corneal thickness and curvature. The purpose of this study was to compare IOP measurements using GAT and DCT in eyes undergoing LASIK for correction of myopia. METHODS: In a prospective, single-center study, central corneal thickness (CCT) and IOP were measured in patients undergoing first-time LASIK for myopia. IOP was measured before and after surgery using GAT and DCT. The untreated contralateral eyes served as paired controls. RESULTS: There was good concordance between the two tonometers in 62 normal eyes before LASIK. Corneal ablation of 90.0 +/- 49.18 micro m (median +/- SD) reduced IOP readings as measured by GAT by 3.0 +/- 1.9 mm Hg (P < 0.001). In contrast, no significant change in IOP readings was recorded by DCT (-0.2 mm Hg +/- 1.5 mm Hg, P = 0.30). There was no change in IOP in the untreated control eyes as measured by GAT and DCT. CONCLUSIONS: Significant decreases in IOP were recorded by GAT after LASIK for myopia. Measurements by DCT, however, did not reveal any significant changes in IOP.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号