1.
Four rapid tests for the serologic diagnosis of leptospirosis were evaluated, and the performance of each was compared with that of the current standard, the microscopic agglutination test (MAT). The four rapid tests were a microplate immunoglobulin M (IgM)-enzyme-linked immunosorbent assay (ELISA), an indirect hemagglutination assay (IHA), an IgM dipstick assay (LDS), and an IgM dot-ELISA dipstick test (DST). A panel of 276 sera from 133 cases of leptospirosis from four different geographic locations was tested as well as 642 sera from normal individuals or individuals with other infectious or autoimmune diseases. Acute-phase sera from cases (n = 148) were collected or=15 days after onset (median = 29.1). By a traditional method (two-by-two contingency table), the sensitivities for detection of leptospirosis cases were 93.2% by LDS, 92.5% by DST, 86.5% by ELISA, and 79.0% by IHA. Specificity was 98.8% by DST, 97% by ELISA and MAT, 95.8% by IHA, and 89.6% by LDS. With a latent class analysis (LCA) model that included all the rapid tests and the clinical case definition, sensitivity was 95.5% by DST, 94.5% by LDS, 89.9% by ELISA, and 81.1% by IHA. The sensitivity and specificity estimated by the traditional methods were quite close to the LCA estimates. However, LCA allowed estimation of the sensitivity of the MAT (98.2%), which traditional methods do not allow. For acute-phase sera, sensitivity was 52.7% by LDS, 50.0% by DST, 48.7% by MAT and ELISA, and 38.5% by IHA. The sensitivity for convalescent-phase sera was 93.8% by MAT, 84.4% by DST, 83.6% by LDS, 75.0% by ELISA, and 67.2% by IHA. A good overall correlation with the MAT was obtained for each of the assays, with the highest concordance being with the DST (kappa value, 0.85; 95% confidence interval [CI], 0.8 to 0.90). The best correlation was between ELISA and DST (kappa value, 0.86; 95% CI, 0.81 to 0.91). False-positive LDS results were frequent (>or=20%) in sera from individuals with Epstein-Barr virus, human immunodeficiency virus, and periodontal disease and from healthy volunteers. The ease of use and significantly high sensitivity and specificity of DST and ELISA make these good choices for diagnostic testing.  相似文献   

2.
3.
Thrombomodulin is a transmembranous glycoprotein of endothelial cells. In vitro it is a marker of endothelial cell injury. In vivo the levels of soluble serum thrombomodulin are regarded as parameters of disease activity in vasculitides and vasculopathies. However, the mean thrombomodulin values of different studies show marked concentration differences of the control values. The purpose of this study was to further investigate these differences. We examined 60 sera of patients with systemic lupus erythematosus (SLE) and 10 of healthy controls with three commercially available thrombomodulin ELISA kits for determination of their thrombomodulin concentration and correlation to disease activity. The disease activity of the SLE patients was determined with the SLAM-score. Raised thrombomodulin values were found in 58% (test A), 55% (test B) and 61.6% (test C). The thrombomodulin values significantly correlated with the SLE disease activity independently of the ELISA kit used (correlation coefficients: r=0.84 (test A), r=0.80 (test B), and r=0.65 (test C)). In addition, the correlation coefficients between the respective thrombomodulin values of the three tests were r=0.86 (test A to B), r=0.73 (test A to C) and r=0.79 (test B to C). However, significant differences between the results of the three ELISA kits were found between the detected thrombomodulin concentrations. The mean thrombomodulin concentrations of the controls were 25.6 ng/ml (test A), 3.53 ng/ml (test B), and 2.52 ng/ml (test C). Our results reveal that the soluble thrombomodulin values of all three commercially available ELISA kits significantly correlate with the disease activity of SLE patients. However, the results show significant differences in the determined thrombomodulin concentrations. A calibration would be required of the different ELISA kits in order to permit a direct comparison of the results of these thrombomodulin ELISAs. A general reference standard would be desirable for this calibration of all thrombomodulin ELISAs. However, this general reference standard has to be adapted to the distinct test conditions of all test kits as well as including all epitopes of thrombomodulin which are recognised by the different antibodies used in the respective test kits. At present, only ELISA kits from the same manufacturer should be used during a single study including any follow-up investigations.  相似文献   

4.
Plates from the County Laboratory, Hollister-Stier and our lab were simultaneously placed in the same locations. Comparisons show increased yield comes from a combination of the latter two and the greatest over-all yield came from our lab. Also multiple-placed plates in the same room show the flora is not static.  相似文献   

5.
A study was undertaken to evaluate the efficacy of commercially available antimicrobial discs manufactured by Oxoid, UK, HiMedia Laboratories, Mumbai and Span Diagnostics, Surat. The discs were evaluated for their performance on the basis of percentage of coefficient of variation (%CV) which is a measure of reproducibility, mean zone diameters which is a measure of accuracy and range of zone diameter using both standard ATCC strains and clinical isolates. The data showed variation for all three manufacturers and therefore routine and regular quality control of discs as well as meticulous following of good laboratory practices is strongly advocated in clinical laboratories.  相似文献   

6.
7.
Extended-spectrum beta-lactamase (ESBL) production in members of the Enterobacteriaceae can confer resistance to extended-spectrum cephalosporins, aztreonam, and penicillin. As such, the accurate detection of ESBL producers is essential for the appropriate selection of antibiotic therapy. Twenty previously characterized isolates and 49 clinical isolates suspected of ESBL production were tested by four ESBL phenotypic confirmatory methods for accuracy and ease of use. The four ESBL phenotypic confirmation tests included Dried MicroScan ESBL plus ESBL Confirmation panels (Dade Behring, Inc., West Sacramento, Calif.), Etest ESBL (AB BIODISK, Piscataway, N.J.), Vitek GNS-120 (bioMerieux, Inc., Hazelwood, Mo.), and BD BBL Sensi-Disk ESBL Confirmatory Test disks (BD Biosciences, Sparks, Md.). Results were compared to frozen microdilution panels prepared according to NCCLS specifications, and discrepant isolates were sent for molecular testing. The test sensitivities for the ESBL phenotypic confirmatory test methods used in this study were as follows: MicroScan ESBL plus ESBL confirmation panel, 100%; VITEK 1 GNS-120, 99%; Etest ESBL, 97%; and BD BBL Sensi-Disk ESBL Confirmatory Test disks, 96%. The test specificities were as follows: BD BBL Sensi-Disk ESBL Confirmatory Test disks, 100%; MicroScan ESBL plus ESBL confirmation panel and VITEK 1 GNS-120, 98%; and Etest ESBL, 94%. All methods were easy to perform; however, the Etest method required more expertise to interpret the results. All tests offer a feasible solution for confirming ESBL production in the clinical laboratory.  相似文献   

8.
9.
Screening and confirmatory low cost reagent tests have been developed for detection of anti-hepatitis C virus (HCV). Assays are based on the use of specific synthetic peptides from several structural and non-structural viral proteins. The efficacy of the screening anti-HCV EIA-Spep assay was compared with both Abbott EIA 2.0 (Abbott Laboratories, North Chicago, IL) and Ortho EIA 2.0 (Ortho Diagnostic Systems, Raritan, NJ) anti-HCV detection kits and the confirmatory EIA-Cpep assay was compared with the Abbott Matrix anti-HCV confirmation test. In the EIA-Spep, a pool of 3 peptides was added to each well of a microtiter plate. In EIA-Cpep, each well was separately coated with 1 of 4 peptides and 1 recombinant protein. A total of 867 blood donor samples from Costa Rica tested simultaneously with the 3 screening assays yielded the same specificity and negative predictive values of > or =99.9% and 100%, respectively. A comparative study on voluntary blood donor samples from Honduras, Nicaragua, and El Salvador using the 2 anti-HCV confirmatory assays revealed different patterns that are 46% positive, 24% indeterminate, and 30% negative with the EIA-Cpep assay vs. 31% positive, 48% indeterminate, and 21% negative with the Matrix assay. A study of 71 patient samples from Costa Rica showed a higher correlation between initially reactive samples when analyzed by the Abbott and Ortho kits, than when the assay results were compared between the Abbott and EIA-Spep kits; the latter detected 7 and 15 non-reactive samples, respectively. These results could reflect the use of a similar antigen source for the 2 commercial assays. The presence of HCV RNA in a group of 29 samples analyzed was related to the simultaneous reactivity in all 3 screening assays. None of the discordant samples had detectable levels of HCV RNA. Economic difficulties for health care services in the developing countries of Central America have prevented implementation of routine anti-HCV blood donor screening tests. This is likely to be the primary reason for uncontrolled dissemination of HCV, and the lack of identification of potential high risk groups. Alternative low cost reagents developed locally as described in this article could be a useful tool in the control of HCV spread throughout the developing world.  相似文献   

10.
11.
Information concerning the validity and reliability of commercial on-line gas analysis systems is limited. The aim of this study was to provide a comparison of the validity and reliability of three on-line systems (Oxycon Alpha, Oxycon Pro and Pulmolab EX670) with that of Douglas bags. Two separate studies were conducted. In study 1, the three gas analysis systems were compared with Douglas bags using a metabolic simulator over four increases in ventilation. In study 2, ten subjects were split into equal groups exercising at 100 W or 150 W for 85 min on three separate occasions. Each system was used twice per visit. Study 1 demonstrated that the Oxycon Alpha and Douglas bags produced similar respiratory values over all levels of ventilation. The Oxycon Pro tended to slightly overestimate mean expiratory flow ( ), oxygen uptake ( ), carbon dioxide production ( ) and respiratory exchange ratio (RER) at the higher ventilations. The Pulmolab produced large overestimations at all ventilations for and RER (up to 26.3% away from expectations), whilst values for , and were slightly underestimated at higher ventilations (up to 7.5% from expectations). The results of study 2 support the findings of study 1, with the Oxycon Pro and Oxycon Alpha producing similar results compared to Douglas bags for , and RER. The coefficients of variation for and measured using Douglas bags, Oxycon Pro and Oxycon Alpha were 3.3–5.1%, 4.7–7.0% and 4.5–6.3%, respectively, whilst that for the Pulmolab was highly variable (26.8–45.8%). The exercise study showed the Oxycon Pro and Oxycon Alpha to be both valid and reliable on-line systems for the measurement of parameters of respiration, at least at workloads up to 150 W. Electronic Publication  相似文献   

12.
13.
Seven commercially available screening tests for rheumatoid factor and two quantitative tests have been compared with the standard Rose-Waaler test in a series of 477 sera from patients with various joint diseases. Markedly different results were obtained, and on the basis of our findings suggestions are made as to what we consider to be the most satisfactory currently available tests.  相似文献   

14.
Photostimulable storage phosphor (PSP) image acquisition systems have been available for several years. The technology has had the opportunity to mature; however, there has not been an independent comparison of recently marketed commercial systems. For this study, three computed radiography (CR) systems using PSP technology (Kodak CR System 400 with autoloader [Eastman Kodak, Rochester, NY], Fuji FCR AC-3CS [Fuji Medical Systems, Stamford, CT], and Agfa ADC Compact [Bayer Corp, Ridgefield Park, NJ]) were connected to an IBM RadWorks diagnostic radiology workstation (IBM Corp, White Plains NY) and evaluated for conformance to their performance specifications using guidance provided in the most recent draft acceptance testing protocol from Task Group No. 10, American Association of Physicists in Medicine. In addition, the physical requirements (eg, space and power) and connectivity to another manufacturer’s diagnostic workstation were examined. X-ray technologist comfort with each PSP imaging system and an assessment by our supporting biomedical equipment maintenance activity of their ability to service each PSP imaging system were also considered.  相似文献   

15.
We evaluated the performance of three enzyme-linked immunosorbent assays (ELISAs) in detecting serum immunoglobulin G (IgG) and IgA antibodies to Helicobacter pylori; two were new ones from Pyloriset (Pyloriset EIA-G update and Pyloriset EIA-A update; Orion Diagnostica, Espoo, Finland), and the third was the Malakit EIA-G (Biolab, Limal, Belgium). Serum samples from 154 dyspeptic patients were collected. As a reference method, multiple biopsy specimens from different anatomical areas of the stomach were obtained by endoscopy and were analyzed by culture and/or histology and direct urease testing. Accordingly, 126 patients (82%) were found to be H. pylori positive and 28 patients (18%) were found to be H. pylori negative. To validate serology as a predictor of H. pylori infection, sensitivity, specificity, positive and negative predictive values, and accuracy of the assays were calculated against the H. pylori status as determined by the reference method. The corresponding data for the different ELISAs were 100%, 79%, 95%, 100%, and 96% for the Pyloriset ELA-G update, 81%, 89%, 97%, 52%, and 82% for the Pyloriset EIA-A update, and 87%, 86%, 96%, 60%, and 87% for the Malakit EIA-G, respectively. We conclude that the Pyloriset EIA-G update is a reliable and accurate test and that because of its 100% sensitivity, conjunctional IgA testing is not necessary. Its 100% negative predictive value makes it a very useful screening test. For purposes of excluding infection with H. pylori, the performance of the Malakit EIA-G is moderate but can be improved by conjunctional IgA testing. The Pyloriset EIA-A update can be useful as such a conjunctional test.  相似文献   

16.
Commercially available assay kits have now made detection of rotavirus in stool specimens possible as a routine laboratory test. One such kit, Rotazyme II (Abbott Laboratories, North Chicago, IL) has been reported to give a higher incidence of false positive results with neonatal stool than with stool from older patients. One hundred stool specimens from asymptomatic neonates (age range, two to five days) were tested by two ELISA methods and one latex agglutination method in order to evaluate the rate of false positivity in this group of patients. Negative staining electron microscopy was used as the reference method. The two ELISA methods were Rotazyme II and Rotavirus EIA (International Diagnostic Laboratories, St. Louis, MO), and the latex agglutination method was Meritec-Rotavirus (Meridian Diagnostics, Inc., Cincinnati, OH). The Rotavirus EIA and Meritec-Rotavirus tests gave 0% and 1% false positive results, respectively, while the Rotazyme II test gave a 4% false positive rate with an additional 19% equivocal results. This extensive comparative analysis of commercially available assays for detection of rotavirus in neonatal stool specimens suggests a false positive or equivocal rate with the Rotazyme II test that impairs clinical utility.  相似文献   

17.
Three commercially available anaerobic cabinets are described and their performance in relation to one another and to a standard anaerobic jar technique are reported upon from a clinical laboratory.  相似文献   

18.
The serodiagnosis of hepatitis C virus (HCV) infection was analyzed by a recombinant immunoblot assay (RIBA) with recombinant proteins encoded by the viral RNA isolated from our patients in Hamburg, Germany. The HCV RNA was amplified by PCR, and proteins encoded by the viral core and the NS3, NS4, and NS5 regions were expressed subsequently in Escherichia coli. The results obtained with our UKE RIBA were compared with the results of the Abbott HCV second-generation enzyme immunoassay (EIA). Serum samples from 270 patients, which were sent to us on the suspicion of HCV hepatitis and which were negative for hepatitis A virus and hepatitis B virus antibodies, were examined. In 227 cases (84.1%), there were identical positive (204 cases, 75.6%) or negative (23 cases, 8.5%) results in both tests. In 32 cases (11.9%), the reactive Abbott second-generation HCV EIA results could not be confirmed by the UKE RIBA and the HCV PCR. In follow-up studies conducted over 1 year, these results did not change. In three cases (1.1%), the UKE RIBA presented a positive result while the Abbott second-generation HCV EIA was negative. All three cases were positive in the HCV PCR and showed seroconversion in an HCV EIA 4 to 6 weeks later. In addition, 33 patient serum samples were examined by UKE RIBA in parallel with the Ortho RIBA 2.0. In three cases (9.1%), a positive Ortho RIBA 2.0 result could not be confirmed by the UKE RIBA and the HCV PCR. All three patients were free of complaints. The UKE RIBA showed also a smaller number of indeterminate results (3.0%) than the Ortho RIBA 2.0 (24.2%). This comparison study demonstrates that the commercially available HCV antibody tests should be further improved.  相似文献   

19.
The new generation of oxygenators have improved blood flow pathways that enable reduction in priming volume and, thus, hemodilution during cardiopulmonary bypass (CPB). We evaluated three oxygenators and two sizes of venous reservoirs in relation to priming volume, gas transfer, and blood activation. To compare priming volume, gas transfer, and biocompatibility of three hollow fiber oxygenators and two different size venous reservoirs, 60 patients were randomly allocated in groups to undergo cardiopulmonary bypass. In each group, an oxygenator with a different surface area and priming volume was used: 1.8 m2 and 220 ml (group 1, n = 23), 2.2 m2 and 290 ml (group 2, n = 20), and 2.5 m2 and 270 ml (group 3, n = 17). In groups 1 and 3, a large soft shell (1900 ml) venous reservoir was used, whereas in group 2, a smaller soft shell (600 ml) venous reservoir was used. Gas transfer was assessed by calculating the oxygen transfer rate for each group and per square meter for each oxygenator group. Partial arterial oxygen pressure (paO2) and partial arterial carbon dioxide pressure (paCO2) between the groups were assessed with forward stepwise regression analysis. Biocompatibility was evaluated through measurement of platelet numbers, complement activation products (C3b/c), coagulation (thrombin anti-thrombin III complex), and fibrinolysis (plasmin anti-plasmin complex). No differences were found in oxygen transfer rate per group. However, when correcting the oxygen transfer rate for surface area, group 1 demonstrated a higher oxygen transfer rate compared with group 2 (p < 0.05) at an FiO2 of 40 and 60% and compared with group 3 at an FiO2 of 60 and 70%. The regression analysis showed that the average arterial PO2 was the highest in group 3, i.e., 79.2 mm Hg higher than in group 1 (p < 0.001) and 73.5 mm Hg higher than in group 2 (p < 0.001). Group 3 also had the lowest average arterial pCO2, 0.57 mm Hg lower than in group 1 (p = 0.004) and 0.81 mm Hg lower than in group 2 (p < 0.001). During CPB, platelet numbers decreased significantly in all groups (p < 0.001), without differences between the groups. C3b/c levels increased in all groups during CPB. At cessation of CPB the C3b/c level in group 2 (398 nmol/L(-1)) was significantly higher compared to group 1(251 nmol/L(-1); p < 0.05) and group 3 (303 nmol/L(-1); p < 0.05). Thrombin anti-thrombin III complexes and plasmin anti-plasmin complex complexes increased during CPB to significantly high levels at cessation of CPB, but there were no differences between the groups. The oxygenator with the smallest surface area and lowest priming volume (group 1) had the highest oxygen transfer rate per square meter and showed the least blood damage, as depicted by complement activation. The oxygenator with the largest blood contact surface area and improved geometric configuration (group 3) showed the lowest oxygen transfer rate per square meter. However, this oxygenator elevated oxygen partial pressure the most and reduced carbon dioxide partial pressure the most. In group 2, where a smaller venous reservoir was used, the highest blood activation was observed.  相似文献   

20.
Advances in new technologies for complete slide digitization in pathology have allowed the appearance of a wide spectrum of technologic solutions for whole-slide scanning, which have been classified into motorized microscopes and scanners. This article describes technical aspects of 31 different digital microscopy systems. The most relevant characteristics of the scanning devices are described, including the cameras used, the speed of digitization, and the image quality. Other aspects, such as the file format, the compression techniques, and the solutions for visualization of digital slides, (including diagnosis-aided tools) are also considered. Most of the systems evaluated allow a high-resolution digitization of the whole slide within about 1 hour using a x40 objective. The image quality of the current virtual microscopy systems is suitable for clinical, educational, and research purposes. The efficient use of digital microscopy by means of image analysis systems can offer important benefits to pathology departments.  相似文献   