《Acta orthopaedica》2013,84(5):640-647
Background?Diagnosis of an infected arthroplasty is often difficult. Fever, abnormal physical findings, radiographic changes, findings at bone scintigraphy, an elevated erythrocyte sedimentation rate, CRP, and leucocytosis are not specific enough. We evaluated the diagnostic value of white blood cell scintigraphy.

Methods?We retrospectively reviewed 76 cases (66 patients) admitted for white blood cell scintigraphy with a clinical suspicion of infection in a hip prosthesis during the period 1995–2003. The leukocytes were labeled with 99mTc-HMPAO or with 111In-oxin. Anterior and posterior views were taken of both hip joints at 3 different time points after injection: 1 h, 3 h, and 22 h. Infection was verified by means of bacteriological cultures, histopathological findings, intraoperative frozen sections, and follow-up (up to 3.5 years).

Results?Of 76 scintigraphies, 51 were negative and 25 were positive. There were 81% true positive, 94% true negative, 6% false positive, and 19% false negative outcomes.

Interpretation?White blood cell scintigraphy with additional late imaging is an effective tool for differentiation between loosening and infection in painful hip arthroplasty.  相似文献   

2.
Background Weakness of the abductor muscles—or even their avulsion—is a potential risk when total hip arthroplasty (THA) is performed using the anterolateral approach. Avulsion of the re-attached gluteus medius leads to a limp, but can also provide an open canal for joint fluid to escape to the trochanteric region. Thus, our hypothesis was that arthrography can be used to diagnose such detachment.

Methods We compared THA arthrographies with peroperative findings retrospectively in 33 patients who had undergone surgical exploration for a muscle reattachment because of a strong suspicion of abductor avulsion at physical examination.

Results After a mean follow-up time of 22 (2-57) months after THA, 14/33 patients had a positive (pathological) arthrogram whereas 19 had a negative (normal) result. All 14 patients with a positive arthrogram were verified to have an avulsion of the abductor muscle at the operation. 10 of the 19 patients with a negative arthrogram had an intact abductor insertion, but 9 had an avulsion. All of these 9 patients with the peroperatively disclosed avulsion had a fibrous capsule, which obstructed the fistula leading from the joint cavity to the trochanteric bursa region.

Interpretation Arthrography is a valuable diagnostic aid in the evaluation of patients with abductor weakness and with Trendelenburg's gait appearing after a THA performed using the anterolateral approach. A positive finding helps in the operative decision making, but a negative arthrogram is not a reliable predictor.  相似文献   

3.
Background If it would be possible to detect lack of flow and/or the development of ischemia in bone, we might have a way of predicting whether a broken bone will heal. We established microdialysis (MD) and laser Doppler (LD) flow measurement in the human femoral head in order to be able to detect ischemia and measure changes in blood flow.

Material and methods In 9 patients undergoing total hip arthroplasty for primary osteoarthrosis, two MD catheters were inserted into the femoral head through two drill holes after the blood flow had been visualized by LD. Then primary samples were collected with the femoral head in situ; thereafter, the head was removed and samples were collected over the following 4 hours ex vivo. The variables obtained by MD were concentrations of glucose, lactate, pyruvate, and glycerol in extracellular fluid.

Results The results showed development of ischemia with a statistically significant decrease in glucose concentration and elevation of the lactate/pyruvate ratio over time. The LD showed flow with the femoral head in situ and lack of flow when the femoral head was removed.

Interpretation The use of MD was established in the human femoral head. Ischemic levels were detected within 2 h of cessation of blood flow in most patients.  相似文献   

4.
Background The most common complications of prosthetic hip joints are aseptic mechanical failure and infection. Delayed low-grade infections are seen most often, and they are also most difficult to distinguish from aseptic mechanical failures.

Methods We conducted a prospective study to compare inflammatory markers in patients diagnosed with aseptic or septic prosthetic loosening. The diagnostic criteria were based on the decisions of experienced orthopedic surgeons and microbiological analysis of periprosthetic tissue samples taken perioperatively.

Results Coagulase-negative staphylococci were the commonest pathogens in the infected patients. Pre- or perioperative elevation of C-reactive protein and erythrocyte sedimentation rate were significantly greater in the infection group, as were white blood cell count and levels of cytokines in synovial fluid. The patterns of infiltration of inflammatory cells in periprosthetic tissue were also significantly different between the groups.

Interpretation A combination of clinical judgment and multiple tissue samples constitutes a good platform for distinguishing between septic and aseptic loosening of prostheses. Moreover, the combined use of several laboratory and histopathological markers of inflammation, especially infiltration of polymorphonuclear cells, further helps the diagnosis.  相似文献   

5.
Background Hip fracture incidence rates are high, and increase with increasing age. Previous studies have predicted a continued increase in both crude and age-standardized rates.

Method We estimated incidence rates, based on a complete and validated register containing verified and individually sequenced hip fractures from 1996-2003, for a population of 500,000 people in Funen County, Denmark.

Results The verified number of the first hip fractures was 6,676, with 520 subsequent fractures. Between 1996 and 2003, the incidence rate of first hip fracture fell by 2.4% per year for males (p = 0.02) and by 1.8% per year for females (p = 0.004). The highest decrease of 3.4% per year (p = 0.02) was seen in 80-84-year-old women.

Interpretation The incidence rate of the first hip fracture has fallen in both sexes. In most age groups, the actual number of fractures has also decreased. The findings emphasize the need for valid projection studies which should include both demographic projections and modeling of the effects of different levels of prevention.  相似文献   

6.
Background Acetabular cementation during total hip arthroplasty is considered difficult mainly due to the appearance and anatomy of the acetabulum. Improved cementation technique has been shown to improve the longevity of acetabular components.

Method We designed a ceramic model to investigate the effect of varying the initial cement pressurization and cup introduction times on the depth of cement penetration. 4 groups were prepared, 2 of which involved varying initial cement pressurization and cup introduction times. Group 3 involved initial cement pressurization with no cup introduction, while group 4 involved cup introduction with no prior cement pressurization.

Results and interpretation Most cement penetration occurred in the early pressurization phase, and we conclude that a relatively early and longer cement pressurization time and late cup introduction are positive factors for increased cement penetration in the acetabulum model.  相似文献   

7.
Background Femoral component neck fracture is an uncommon type of failure in total hip arthroplasty. We present a report on 4 retrieved cobalt-chrome femoral components that fractured at the neck, where we investigated the mechanisms of failure.

Methods The 4 retrieved implants were analyzed with regard to their macro- and microstructures and the fracture surfaces were examined using electron microscopy. The medical record of each patient was also examined for any history of complications prior to failure of the implant.

Results These fractures occurred immediately adjacent to the base of the modular head. Skirted modular heads were used in 3 of the 4 failed components. This constructs promotes corrosion. Cyclic fatigue-loading in combination with the material factors of course grain microstructure and extensive carbide precipitation along the grain boundaries were also identified as the cause of implant failure.

Interpretation Our findings suggest that a solution annealing step could be introduced into the manufacturing process to improve the microstructure of the cobalt chrome alloy. We also advise caution in using a skirted modular head in combination with a device of known suboptimum microstructure, for a greater margin of safety.  相似文献   

8.
Background Aseptic loosening is the major cause of implant failure. In cemented hip arthroplasty, failure of the acetabular side is mainly due to lysis caused by wear particles. By using an implant with low wear characteristics and by enhancing acetabular fixation using an uncemented implant, we aimed to reduce acetabular lysis and thereby loosening.

Patients and methods This was a retrospective cohort study of 119 hips (101 patients) that had the Uncemented Fitmore cup (Sulzer Orthopedics). In 66 patients, the femoral component was CF-30 (Sulzer) used with cement. In the remaining 35 patients, thrust plate prosthesis (TPP) (Sulzer) was used. Of the 101 patients, 94 (112 hips) were available for study. Mean follow-up of the 94 patients was 7 (5-13) years.

Results The mean preoperative Harris hip score was 38 and the mean postoperative Harris hip score was 89 at the last follow-up. Taking aseptic loosening as the endpoint, the survival rate of the Fitmore cup was 100% at 11 years.

Interpretation The uncemented Fitmore acetabular cup with second generation metal-on-metal articulation showed good results with regard to aseptic loosening in the medium term.  相似文献   

9.
Background The initial stability of an exchanged hip arthroplasty is crucial for the survival of the revised joint. Several factors can affect the outcome. The amount of liquid in morsellized bone has a major influence on the constrained stiffness properties of impacted bone applied in revision joint surgery.

Method To determine whether water or fat is the main contributing liquid, we performed an experimental study on impacted morsellized cortico-cancellous bovine bone to compare the constrained e-moduli in native bone and bone with modified water and fat content. The bone was impacted into bone pellets by a standardized method by which the construction procedure was monitored. Other stiffness properties were recorded during subsequent load testing.

Results Low water content significantly increased the constrained stiffness moduli during load, while high water content significantly reduced it. Low fat content increased stiffness significantly only during the initial phase of loading.

Interpretation Our findings indicate that the preparation and usage of morsellized bone in revision joint surgery should be performed under dry conditions to improve the initial stability of the revised prosthesis. ▪  相似文献   

10.
Introduction Recent reports have suggested that selective COX-2 inhibition may be sufficient for the prevention of heterotopic ossification.

Methods We performed a randomized controlled study to evaluate the effect of the selective COX-2 inhibitor rofecoxib compared to that of indomethacin on the incidence and extent of heterotopic ossification in patients who had undergone hip replacement surgery. 50 patients received a daily dose of 25 mg rofecoxib and 50 patients received a daily dose of 100 mg indomethacin (25, 25, and 50 mg).

Results No ossifications were found in 48 patients. Grade-II ossifications were seen in 5/46 patients in the rofecoxib group and in 6/50 patients in the indomethacin group. Grade-III and grade-IV ossifications were seen in 3/46 patients in the rofecoxib group only. The differences were not statistically significant. The study medication had to be discontinued in 2 patients in the indomethacin group, due to dyspepsia.

Interpretation After short-term administration, the selective COX-2 inhibitor rofecoxib was effective in preventing heterotopic ossification after total hip arthroplasty.  相似文献   

11.
Introduction Digital correction of the magnification factor is expected to yield more accurate and reliable preoperative plans. We hypothesized that digital templating would be more accurate than manual templating for total hip and knee arthroplasties.

Patients and methods Firstly, we established the interobserver and intraobserver reliability of the templating procedure. The accuracy and reliability of digital and analog plans were measured in a series of 238 interventions, which were all planned using both techniques.

Results Interobserver reliability was good for the planning of knee arthroplasties (κ-values 0.63-0.75), but not more than moderate for the planning of hip arthroplasties (κ-values 0.22-0.54). Analog plans of knee arthroplasties systematically underestimated the component sizes (1.1 size on average), while the digital procedure proved to be accurate (0.1-0.4 size too small on average). The following figures show percentage of cases receiving a correct implant, allowing an error of one size. Digital templating of the hip arthroplasty was less frequently correct (cemented cup and stem: 72% and 79%; uncemented cup and stem: 52% and 66%) than analog planning (cemented cup and stem: 73% and 89%; uncemented cup and stem: 64% and 52%).

Interpretation Planning of component sizes for total knee arthroplasties is an accurate procedure when performed digitally. Our digital preoperative plans which were performed by someone other than the surgeon were less accurate than the analog plans prepared by the surgeon.  相似文献   

12.
Background Periprosthetic bone loss is a well-docu-mented phenomenon after uncemented total hip arthroplasty (THA); however, little is known about how bone mineral density (BMD) changes after 2 years.

Patients and methods 14 patients with hip arthrosis (group A) were operated with a proximally porous- and hydroxyapatite-coated stem and followed for 10 years with DEXA, radiographs and Harris hip score (HHS). Another group of 14 patients (group B) was evaluated at 6 and 14 years using the same prosthesis and protocol.

Results No stem was revised and all stems were well-Fixed. At final follow-up, HHS was 97 points in group A after 10 years and 94 points in group B after 14 years. Bone mineral changes in group A were greatest in Gruen zones 1 and 7, where the losses were 31% and 26%, respectively, after 2 years on the operated side. The decrease in BMD continued after 2 years and in Gruen zone 7 it was faster than the rate of bone loss on the control side. In group B, the annual change in BMD on the operated side was not significantly different from the bone loss in group A.

Interpretation Up to 14 years after implantation of a tapered uncemented stem, the BMD in the calcar region continues to decrease faster than would be expected from normal ageing.  相似文献   

13.
Background Hip replacement as a routine procedure was introduced in Lithuania in 1991. At Klaipeda Hospital, one of the 2 hospitals at which this was begun, the arthroplasties were followed prospectively from the start. This study concerns the 10-year results from a country with no previous experience of hip replacement. The results are compared with those from a hospital with considerable experience of total hip replacement.

Methods We compared the revision rate for the first 658 primary ScanHip arthroplasties inserted at Klaipeda to that for the first 939 ScanHip primary arthroplasties inserted at Lund University Hospital, Sweden. Only patients with osteoarthritis were included, and the endpoint was revision for aseptic loosening with exchange of one or both components.

Results We found that patients operated at Klaipeda Hospital had a significantly higher risk of revision (12%) than those operated in Lund (6%).

Interpretation Although we could not identify any specific reason for the Swedish results being better than the Lithuanian results, it is probable that previous surgical inexperience of hip replacement in Lithuania played a role. We believe that the findings will stimulate surgeons in Lithuania to analyze their failures and improve the results.  相似文献   

14.
Background and purpose Conversion total hip replacement (THR) is a common procedure after failed hemiarthroplasty, but there have been few reports describing the long-term outcome of this procedure.

Patients and methods Between 1987 and 2004, 595 THRs were reported to the Norwegian Arthroplasty Register as conversion THR for failed hemiarthroplasty after a femoral neck fracture in patients aged 60 years and older. 122 operations left the femoral stem intact, whereas 473 were converted with exchange of the femoral stem.

Results We found a lower risk of failure (revision surgery for any reason) for the conversion procedures with stem exchange (RR = 0.4; 95% CI: 0.25-0.81) than for the conversion procedures that retained the femoral stem. For the 473 conversion arthroplasties with exchange of the stem, we found no difference in risk of failure compared to all revision stems in the register, either for the complete prosthesis (RR = 0.8; CI: 0.50- 1.20) or for the stem (RR = 0.9; CI: 0.53-1.59). However, for the 122 conversion procedures in which the femoral stem was retained, we found a significantly increased risk of failure for both the complete prosthesis (RR = 4.6; CI: 2.8-7.6) and for the acetabular cup (RR = 4.8; CI: 2.3-10) compared to primary hip arthroplasties.

Interpretation Our findings indicate that the seemingly easy operation of implanting an acetabular cup to convert a hemiarthroplasty to a total hip arthroplasty is an uncertain procedure and that the threshold for replacing the stem should be low.  相似文献   

15.
Background and purpose Acute prosthetic infection is a serious problem. We report factors related to the incidence of acute infection and results of combined joint debridement and prolonged rifampicin-based antibiotic therapy.

Patients and methods Between 1998 and 2004, 14 acute infections occurred after 819 primary hip arthroplasties. The association between patient-related and surgical factors and the risk of infection were analyzed. Infections were treated with multiple joint lavage, debridement, 2 weeks of antibiotic therapy, and then oral antibiotics for a minimum of 6 months.

Results There was a correlation between having a body mass index (BMI) of ≥ 30, and also more than 2 co-morbidities, and an increased risk of infection. Diabetes was a potential risk factor. Following our regime of treatment, 11 of 14 patients retained their prosthesis. 2 of 3 who required resection arthroplasty underwent successful staged revision, while the third patient had no further surgery because of being deemed unfit.

Interpretation Primary joint replacement was salvaged in 11 of 14 patients. When successful re-implanta-tion was included, 13 of 14 patients had a mobile prosthetic joint without further infection.  相似文献   

16.
Background After total hip replacement, increased bone metabolism is seen. A local periprosthetic osteopenia can be measured by dual-energy X-ray absorptiometry (DXA), but it is still unkown whether biochemical markers can be used to monitor the local remodeling at an earlier stage.

Patients and methods In this prospective study we compared the biochemical markers tartrate-resistant acid phosphatase 5b (TRAP 5b), bone ALP, osteocalcin and CrossLaps with periprosthetic DXA in 17 consecutive patients after uncemented total hip replacement.

Results We found a highly significant early increase in TRAP 5b after 2 weeks and 6 weeks, which was followed by a densitometrically detectable decrease in bone mineral density after 26 weeks, especially in periprosthetic section Gruen zone 7. Bone ALP and osteocalcin levels as markers of osteoblast activity, and also Cross-Laps as a further marker of osteoclast activity, did not appear to allow any significant prediction of local bone remodeling.

Discussion Our findings show that TRAP 5b is a sensitive parameter for monitoring of osteoclast activity after cementless total hip replacement, and may predict local osteopenia.  相似文献   

17.
Background Recurrent dislocation in total hip replacement is difficult to treat and causes severe morbidity.

Patients and methods 12 patients suffering dislocations were reoperated with a socket wall addition device (anti-luxation ring) for the Lubinus SPII prosthesis, and were followed up after a mean of 4.5 (1-9) years with regard to redislocation, function and radiographic loos-ening.

Results 1 of the patients suffered a redislocation after almost 7 years of use. There was no loosening during the follow-up time. A Harris hip score of 87 (60-100), a health-related quality of life (EQ-5D) index of 0.8 (0.6-1.0) and total range of motion of 145° (125-165) indicate that the patients had a level of function comparable to that of age-matched hip surgery patients with no com-plications.

Interpretation The anti-luxation ring shows promising mid-term results and seems to provide an alternative to more extensive revision surgery for selected patients. ▪  相似文献   

18.
Background Comfort and lack of pain are important for optimal mobilization after hip replacement. We investigated the efficacy of double wound infiltration.

Patients and methods 40 consecutive patients undergoing total hip replacement were randomized into two groups in this double-blinded study. They received wound infiltration at the end of surgery and through an intraarticular catheter 24 h postoperatively. The catheter was placed at the end of surgery. One group received solutions of ropivacaine, ketorolac, and adrenaline. Patients in the control group were injected with saline instead. The observation period was 6 weeks.

Results The patients who received the analgesic solution had less pain up to 2 weeks postoperatively. They reached an earlier and lower pain minimum during the first days postoperatively, had lower use of analgesia up to day 4 postoperatively, and were more satisfied. Use of analgesic solution resulted in less joint stiffness and better function 1 week postoperatively.

Interpretation Operative and postoperative wound infiltration with multimodal drugs reduces pain and the requirement for analgesics after hip replacement, leading to faster postoperative mobilization.  相似文献   

19.
Background The diagnosis of a suspected infected prosthesis is often difficult, but is important for the choice of treatment. Even at surgery, it is not easy to assess whether the prosthesis is infected or not—even though this may be important for the choice of surgical procedure.

Patients and methods We assessed the sensitivity, specificity, predictive value, and reliability of the results of the analysis of frozen sections from samples of tissues taken during revision hip surgery of 136 probably infected prostheses. Samples of tissues were taken to be analyzed immediately from frozen sections, to be processed on a routine basis later, and to be referred for bacteriological cultures. A finding of 5 or more polymorphonuclear leukocytes per field at a magnification of 400× was considered positive for infection.

Results The analysis of frozen sections for infection was in agreement with the results of routine histopathology in 134 of 136 cases. Comparison with the results of culture showed a sensitivity of 85%, a specificity of 87%, a PPV of 79%, an NPV of 91%, and a Kendall's tau correlation coefficient of 0.72.

Interpretation We believe that the method we have tested is of value in revision surgery when infection cannot be ruled out.  相似文献   

20.
Background The use of massive bone allografts in cases of revision of failed total hip arthroplasties (THAs) due to infection is controversial.

Patients and methods 18 patients presented with infection at the site of a THA and were treated with a two-stage protocol. In the first stage, the prosthesis was removed together with all necrotic tissues and cement material if present. A custom-made mold of Palacos R cement containing 1 g of gentamicin was then inserted in 17 of the 18 patients. Systemic antibiotics were used during the interval period. In the second stage, the patients had either acetabular or femoral reconstruction using bulk allograft bone.

Results Mean follow-up was 9 (5-14) years. 1 patient presented with recurrent infection and underwent a Girdlestone resection arthroplasty as definitive treatment. Another patient had a mechanical failure of the acetabular component, which was revised 10 years after the second stage of the reconstruction. The mean Harris Hip Score improved from 34 points preoperatively to 71 points at the last review. By our definition, 16/18 of the patients had a successful outcome.

Interpretation Our results support the use of massive allografts in staged reconstructions of infected THAs complicated by considerable bone loss. ▪  相似文献   