首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Impact of specimen handling and storage on detection of hepatitis C virus RNA   总被引:10,自引:0,他引:10  
Direct detection of hepatitis C virus (HCV) RNA in serum or plasma is useful for validating the performance of anti-HCV assays and for the discrimination of persons with persistent HCV infections from those with resolved infections. Quantitation of HCV RNA may also be useful for disease prognosis and therapeutic monitoring. Previous studies have reported detection of HCV RNA in 50 to 70 percent of blood donors who were positive on anti-HCV supplemental tests. There is concern that specimen processing and storage conditions might influence the stability, and hence the detectability, of HCV RNA. To address this concern, the rate of detection of HCV RNA by the polymerase chain reaction (PCR) using donor pilot tube sera (PTS) previously subjected to routine donor screening and supplemental testing was compared with HCV PCR results obtained with fresh-frozen plasma (FFP) derived from the same donations. All 16 anti-HCV supplemental test-positive donations evaluated were HCV RNA positive with FFP, whereas only 10 (62.5%) were positive with PTS (p = 0.024). None of 11 FFP or PTS samples from HCV enzyme immunoassay-reactive donations not confirmed by supplemental anti-HCV assays tested positive for HCV RNA. Direct comparison of sample type (serum vs. plasma) and various storage conditions using specimens from two seropositive donors showed that room-temperature storage results in marked reduction in HCV RNA signal, while replicate freezing and thawing caused a moderate reduction. These data indicate that well-controlled sample processing and storage conditions are critical to the sensitive and potentially quantitative analysis of HCV RNA.  相似文献   

2.
This look-back study was undertaken to identify newborn infants who had been infected with the hepatitis C virus (HCV) as a result of transfusions received before the introduction of routine screening in 1991 and to determine the transmission rates and persistence of transfusion-transmitted HCV infection acquired in the neonatal period. A total of 24 infants, transfused between 1980 and 1991, were identified as having received potentially infected blood from 11 blood donors. Ten of the donors had been administered batches of anti-D in 1977 known to have transmitted HCV genotype 1b infection. HCV RNA was detected in five of these donors when tested in 1994–95; the past donations of five of the donors, who had received anti-D immunoglobulin and had serological evidence of previous HCV infection but who were PCR negative when tested in 1994–95, were considered of lower risk. The source and time of acquisition of HCV infection for the one remaining donor in the study was not determined. Twenty-one (88%) of the 24 children were living at time of lookback. The median age at transfusion was 12 days. The median age at time of testing was 6.3 years. One child, who tested negative, was excluded from further analysis of HCV transmission, due to incomplete transfusion records. Overall, 12 of 20 (60%) children tested were positive for anti-HCV and seven (35%) were HCV RNA positive. Twelve (71%) of the 17 recipients of viraemic blood were ELISA positive and seven (41%) were PCR positive. Resolved HCV infection, as determined by ELISA pos, RIBA pos or indeterminate and PCR negativity, occurred in five of 12 (42%). In many instances there was more than one recipient per HCV infected donation. All of the reported children are clinically asymptomatic. However, the duration of HCV infection is relatively short and there is evidence of a degree of hepatitis in five of the seven children who are HCV RNA positive as judged by mildly elevated transaminase levels. The three who have undergone liver biopsy show mild hepatitis. The lower rates of persistence of HCV infection in this study may be due to the young age at exposure or to the source of infection which for all but one of the children was linked to one HCV genotype from female donors. Sharing of units of blood among multiple infants should be discouraged.  相似文献   

3.
Introduction of the nucleic acid amplification technique (NAT) as a screening test for blood donors to detect HCV RNA became mandatory on 1 April 1999. Few automated commercial systems are available for HCV RNA detection at the moment. The Cobas Amplicor HCV 2.0 System is able to perform fully automated amplification and detection of nucleic acids. A concentration of 98 IU HCV RNA/ml can be detected by the Cobas Amplicor HCV 2.0 System (n = 233, in 100% of the cases). With a pool size of 40 donor samples, the guidelines of the Paul-Ehrlich-Institute concerning sensitivity (5,000 IU HCV RNA per mL in a single donation) were followed. One whole blood donation was identified as HCV-RNA positive (anti-HCV IgG negative, GPT < 30 U/L) during a period of 5 months. No false positive test results could be observed. The internal control and the run control are primarily helpful to monitor methodological problems.  相似文献   

4.
5.
There are periods within the early phase of hepatitis C virus (HCV) infection in which the anti-HCV antibody test is unable to confirm HCV viremia. To reduce the risk of transmitting HCV through transfusions, we developed a simple and highly sensitive enzyme immunoassay (EIA) which detects the core antigen of HCV (HCVcAg). This assay employed a conventional colorimetric EIA system, and was based on a two-step sandwich assay, using a 96- well microplate. The reproducibility of the results was very high. When the cutoff values were set to 30 fmol of recombinant HCVcAg/L, as determined by the distribution of healthy subject sera (n=223), 99.6% of healthy subject sera and 100% of hepatitis B patient sera (n=50) were negative for HCVcAg. The clinical performance of this EIA was examined using 14 commercially available seroconversion panels. In every panel, HCVcAg could be detected at points preceding the seroconversion of anti-HCV antibodies. The points at which HCVcAg was detected were the same as those at which it was detected by an AMPLICOR HCV Monitor test. The EIA's window period for detecting the HCVcAg in all panels was on average 26 days shorter than that of the anti-HCV antibody test. In three panels where the first sample is negative for HCV RNA, the window period was shortened 50 days by this EIA for HCVcAg. There was a positive correlation between the concentration of HCVcAg and HCV RNA in anti-HCV antibody negative specimens. This assay was simpler to perform than assays based on gene amplification technology for the detection of HCV RNA, and the window period was shortened to that of the AMPLICOR HCV Monitor test. Thus, the EIA for HCVcAg would be useful in screening seroconverting donors and could reduce the residual risk of secondary HCV infections through transfusions.  相似文献   

6.
双抗原夹心ELISA检测抗HCV总抗体   总被引:1,自引:0,他引:1  
目的建立检测抗HCV抗体的双抗原夹心ELISA法,评价其可行性。方法将与His或GST融合表达的HCV基因工程抗原,分别用作ELISA的包被和酶标记抗原,建立用于抗HCV总抗体检测的双抗原夹心ELISA。用此方法检测1 968份临床血清标本,并以间接ELISA(北京万泰试剂)与之对照;此外,用套式RT-PCR检测部分血清的HCV RNA。结果有1 761份血清2种ELISA检测均为阴性,有190份血清均为阳性,两种方法符合率为99.1%;有17份血清的检测结果不相符,间接法阳性而本法阴性的14份,其中HCV RT-PCR阳性1份;本法阳性而间接ELISA阴性的3份,其中RT-PCR阳性2份。双抗原夹心ELISA与间接ELISA的敏感性分别为99.48%、98.96%,特异性分别为99.94%、99.27%。结论新研制的检测抗HCV总抗体的双抗原夹心ELISA具有较高的敏感性和特异性,值得作进一步的深入研究。  相似文献   

7.
BACKGROUND: Tests for hepatitis C antibodies (anti-HCV enzyme immunoassays) are usually described as positive or negative. Several studies, mainly in blood donors, have found that specimens with low signal/cutoff (S/C) ratios are commonly negative when tested with a recombinant immunoblot assay (RIBA) or for HCV RNA. METHODS: We retrospectively reviewed 17 418 consecutive anti-HCV results from a screening program for high-risk veterans; 2986 (17.1%) samples were anti-HCV-positive, and 490 (16.4%) had S/C ratios 相似文献   

8.
The risks of transmitting viral infection by blood and products derived from plasma have long been known and still remain an area of concern. Blood banks and transfusion centres are faced with the imminent introduction of nucleic acid amplification testing (NAT) of plasma pools as used by the plasma industry. In this paper, we show a part of our results of a validation study of an in-house method for routine polymerase chain reaction (PCR) screening for hepatitis C virus (HCV) RNA in plasma pools and the results of testing 2,718 anti-HCV negative plasma pools for the presence of HCV RNA. The European Committee for Proprietary Medical Products (CPMP) recommended that from 1 July 1999, only batches derived from plasma pools tested and found non-reactive for HCV RNA, using validated test methods of suitable sensitivity and specificity, should be batch released by authorities. The quality and efficiency of NAT detection of HCV RNA is among others influenced by the efficacy of RNA isolation, the primer selection and the use of control samples. Using modern molecular biology techniques (sensitive and specific in-house amplification methods for detection of HCV RNA and automated sequencing), we analysed samples of plasma pools from different Croatian transfusion centres. By detection of HCV RNA in an NIBSC working reagent (genotype 3) and a Pelispy HCV RNA run control (genotype 1) we determined a high reproducibility and sensitivity (below 100 International Units (IU)/ml) for our in-house method. By direct sequencing PCR cDNAs we proved the specificity of the test system and the possibility of determining the HCV genotype when the method was used for PCR screening of HCV RNA in single donations. Of 2,718 anti-HCV negative plasma pools we have found that 2.1$ were HCV RNA positive. Results of our investigation confirm the necessity of testing HCV RNA in plasma pools to further increase the safety of human plasma-derived drugs.  相似文献   

9.
Risk factors in hepatitis C virus-infected blood donors   总被引:2,自引:0,他引:2  
Risk factors of parenteral and nonparenteral exposure to hepatitis C virus (HCV) infection were studied in 125 blood donors in The Netherlands who were positive for anti-HCV on enzyme-linked immunosorbent assay (ELISA). Risk factors were related to confirmatory test results of four-antigen recombinant immunoblot assay (4-RIBA) and polymerase chain reaction (PCR) of the HCV 5' untranslated region. Twelve (10%) of the 125 anti-HCV C100 ELISA-positive blood donors were 4-RIBA positive. Eleven (92%) of 12 4-RIBA-positive blood donors were PCR positive, and all 113 remaining 4-RIBA-negative or -indeterminate donors were PCR negative. Eleven (92%) of 12 4-RIBA-positive blood donors had a risk factor of parenteral exposure, as compared to 17 (15%) of 113 4-RIBA-negative or -indeterminate donors. The prevalence of confirmed HCV infection among Amsterdam blood donors is calculated at 0.04 percent; parenteral exposure appears to be the major risk factor for HCV infection.  相似文献   

10.
目的 建立荧光定量两探针检测HCV RNA方法.方法 对105例抗HCV抗体阳性和220例阴性样本,用荧光定量两探针法和2种商品荧光定量试剂进行检测,并对检测结果进行比较.结果 荧光定量两探针法阳性率分别为89.5%(94/105)和2.3%(5/220).两种商品荧光定量试剂阳性率分别为71.4%(75/105)和0.45%(1/220);69.5%(73/105)和1.8%(4/220).结论 荧光定量两探针法检测HCV RNA有较高的敏感性和特异性.  相似文献   

11.
Sera from 49,088 blood donors were tested for markers of hepatitis C virus (HCV) infection and decreased hemolytic activity after they had been stored at 4 degrees C for 24 h, a phenomenon known as the cold activation of complement. Antibody to HCV (anti-HCV) was detected in 315 (0.64%) units, of which 181 (57%) were positive for HCV RNA. The cold activation of complement was detected in 170 (0.35%) units, and HCV RNA was detected in 140 (82%) of them. Thus, the cold activation of complement was observed in 140 (77%) of 181 blood units with HCV RNA. The close association of HCV viremia with the cold activation of complement would be useful as a surrogate test in preventing post-transfusion HCV infection in developing areas where anti-HCV assays are not easily performed.  相似文献   

12.
13.
抗-HCV阳性献血者血清HCV RNA水平与ALT活性的关系   总被引:3,自引:0,他引:3  
目的 分析抗-HCV阳性献血者血清HCV RNA含量与ALT活性的关系。方法 采用ELISA法检测抗-HCV,阳性标本用荧光PCR试剂盒测定HCV RNA,分析标本ALT活性与HCV RNA水平的关系。结果 60份抗-HCV阳性标本经PCR检测后有27份标本含有HCV RNA,HCV RNA拷贝量与ALT活性呈正相关,且标本的HCV RNA含量越多,ALT活性也越高(P<0.01)。结论 献血者中筛查ALT并结合PCR技术,能减少HCV经血传播的危险。  相似文献   

14.
A new immunoassay for the detection of hepatitis C core antigen (HCVcoreAg) in peripheral blood during serological window-phase was evaluated among healthy blood donors, commercially available hepatitis C virus (HCV) seroconversion panels and in-house specimens from individuals undergoing seroconversion. Among 1964 low-risk blood donor samples, seven samples were initially reactive but only one was repeat reactive. Reactivity of this specimen was not confirmable by neutralization with specific anti-HCV core antibody, and the sample was negative for HCV RNA by polymerase chain reaction (PCR). The specificity of the HCVcoreAg enzyme-linked immunosorbent assay (ELISA) was 99.95%. In seven commercially available HCV seroconversion panels, HCVcoreAg appeared 23-46 days earlier than anti-HCV antibody by third generation assay. Additional testing with specimens from patients undergoing anti-HCV seroconversion indicated that HCVcoreAg becomes undetectable by the present test format soon after the onset of antibody. This test may be considered as an alternative to nucleic amplification techniques (NAT) for blood donor HCV screening. Additional development of technology for detecting HCVcoreAg may be useful for patient diagnosis and therapy monitoring.  相似文献   

15.
Diagnostic testing for hepatitis C virus (HCV) infection currently is based on the presence of anti-HCV antibodies or a positive HCV RNA polymerase chain reaction (PCR) test. Although HCV RNA PCR is a sensitive and specific technique, widespread application is limited. Moreover, HCV RNA PCR is subject to false-positive reactions through contamination and is inherently difficult to standardize and quantitate. To overcome limitations of HCV RNA PCR, we produced both cDNA and riboprobes from a 241 nucleotide sequence of the 5' untranslated region of the HCV genome for slot hybridization. Hybridization was absent using normal human serum, horse serum, or hepatic cellular RNA from noninfected liver. Hybridization occurred predominantly with positive-stranded HCV RNA and was abolished by pretreatment with RNase A. Slot hybridization was performed on serum samples from 60 patients with chronic HCV infection and a positive HCV RNA PCR and 20 patients with liver diseases unrelated to HCV who had a negative HCV RNA PCR. Slot hybridization with cDNA and riboprobes showed concordance with HCV RNA PCR of 95 and 98.3%, respectively. There were no false-positive reactions in controls. The sensitivity of riboprobe hybridization was comparable to that of one stage HCV RNA PCR using 5' untranslated region primers. Riboprobe hybridization with the HCV H strain standard was positive in the dilution corresponding to 10(-6) chimpanzee infectious doses50/ml. The density of the hybridization signals correlated significantly with the mass of an RNA standard extracted from the liver of a patient with HCV infection. The relative quantities of HCV RNA in the sera of selected patients varied and were not correlated with the duration of disease or the histopathological stage. The highest relative quantities were associated with concurrent immunosuppression. We conclude that slot hybridization is a sensitive, specific alternative to HCV RNA PCR that can be directly quantitated using appropriate HCV RNA standards.  相似文献   

16.
The purpose of the study was to elucidate whether hepatitis C virus (HCV) RNA was present in the blood of patients from a Moscow therapeutic-and-prophylactic institution with uncertain results of a study of anti-HCV that were obtained using the algorithm developed for mass screening. The two-stage scheme of testing the serum for anti-HCV, which was obligatory in accordance with the Order of the Ministry of Health of the Russian Federation, was supplemented by a study the samples having a low optical density samples and those with controversial results in the test systems with the expanded spectrum of detectable anti-HCV, the instructions of which comprises criteria for an uncertain result. Sera with uncertain results of anti-HCV tests were assessed by two polymerase chain reaction (PCR) techniques for HCV RNA. The cDNA fragments complementary to HCV RNA were detected in the sera obtained from two elderly persons in PCR when a signal was recorded in agarose gel. The other real-time PCR failed to detect RNA in none sera with an uncertain result as to anti-HCV.  相似文献   

17.
Recent studies have shown that total hepatitis C virus (HCV) core antigen, both free and antibody bound, is an accurate indirect marker of viral replication that can be used in clinical practice. The aim of the present study was to evaluate the performance of a new total HCV core antigen enzyme-linked immunosorbent assay (ELISA) for detection and quantification of total core antigen in blood donors, testing positive for anti-HCV antibodies and for prospective low-risk population screening. A population comprising 257 samples, from blood donors detected reactive for anti-HCV antibodies [137 recombinant immunoblot assay (RIBA) positive and 120 RIBA indeterminate], were tested by using a new total HCV core antigen ELISA. HCV-RNA was quantified by using quantitative polymerase chain reaction (PCR) assays in all RIBA-positive samples and RIBA-indeterminate samples that were positive for the total core antigen. Specificity of the assay was studied in 1070 healthy blood donors negative for anti-HCV antibodies. Compared with quantitative PCR assays, the total HCV core antigen assay showed 97.37% sensitivity. The three HCV-RNA-positive samples, which tested negative for the total core antigen, had a low viral load (< 1.4 x 10(4) IU mL(-1)). All samples with more than 1.4 x 10(4) IU mL(-1) of viral RNA were positive for total core antigen, independent of the HCV genotype. Concentration of total core antigen correlated significantly with those of HCV-RNA (r = 0.614, P < 0.0001). Overall specificity in freshly collected blood donor specimens was 99.63%. Our data indicate that the total HCV core antigen ELISA has a sensitivity close to PCR assays in diagnosing HCV infection in blood donors with anti-HCV antibodies and shows an excellent specificity in volunteer donors. This assay, in combination with anti-HCV antibodies screening tests, could be an alternative to molecular assays for HCV infection screening in blood donors.  相似文献   

18.
用酶联免疫夹心法测定肝炎患者血清丙型肝炎抗原   总被引:10,自引:0,他引:10  
目的建立血清中丙肝病毒NS3抗原(HCAg-NS3)的酶免检测方法。方法以特异性强、敏感度高、识别不同HCAg-NS3抗原表位的HCAg-NS3单克隆抗体和高效价的纯化抗-HCV分别作为包被抗体和酶标记抗体,采用夹心ELISA法测定血清中HCAg-NS3抗原。结果优化了酶免疫反应条件;该方法对HCAg-NS3的最低检测限为1—2ng/ml;批内(n=13)及批间(n=3)变异系数(CV)分别为4.51%和5.64%;对52例抗-HCV阳性血清测定HCAg-NS3抗原的检出率为21.2%,对15例HCAg-NS3阳性标本测定HCV RNA的检出率为60%,1350例抗-HCV阴性的其他类型肝炎患者血清标本中,HCAg-NS3检出率为1.7%,50例正常人血清标本的HCAg-NS3抗原测定结果均为阴性。结论该方法敏感性较高,特异性、重复性和稳定性均良好,可以作为早期诊断HCV感染的有效方法。  相似文献   

19.
20.
BACKGROUND: Hepatitis C is the major cause of posttransfusion hepatitis. Blood components that are positive for antibody to hepatitis C virus (anti-HCV) can transmit posttransfusion hepatitis. STUDY DESIGN AND METHODS: To investigate the effect on posttransfusion hepatitis of screening blood donors with a second-generation test for anti-HCV, 249 transfusion recipients who underwent cardiovascular surgery were prospectively followed. Six recipients who were positive for anti-HCV before transfusion and 51 subjects with incomplete follow-up were excluded from this study. RESULTS: Eleven (13.8%) of 80 subjects who received unscreened blood had two successive serum alanine aminotransferase levels > 90 U per L. Seven (8.8% of total) developed anti-HCV and HCV RNA and two (2.5% of total) developed IgM antibody to cytomegalovirus (IgM anti-CMV). By contrast, 3 (2.7%) of the 112 subjects who received anti-HCV-screened blood had two successive serum alanine aminotransferase levels > 90 U per L. None of these three developed anti-HCV and HCV RNA, but two (1.8% of total) showed the development of IgM anti-CMV. The study shows that screening for anti- HCV in blood donors with a second-generation test almost abrogated posttransfusion viral hepatitis C. CONCLUSION: After anti-HCV screening, other body fluid-transmitted viruses such as CMV may become important in posttransfusion hepatitis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号