首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Purpose: Total aortic arch replacement (TAR) with frozen elephant trunk (FET) is the standard operation for treating aortic dissection (AD) patients involving aortic arch with high operative risk due to long circulatory arrest (CA). We used aortic balloon occlusion technique that safely reduced the CA time to 5 min in average and investigated whether it can improve the clinical endpoints.Methods: All patients diagnosed with AD and underwent TAR with FET operation (123 with aortic balloon occlusion and 221 with conventional method) in Fuwai Hospital during August 2017 and February 2019 was reviewed in this retrospective observational study.Results: After propensity score matching, the 30-day mortality of aortic balloon occlusion group and conventional group was 4.88% and 11.38% (P = 0.062), respectively. In multivariate analysis, aortic balloon occlusion is one of the factors that reduced the risk for renal and hepatic injury, shortened postoperative conscious revival time, and reduced red blood cell (RBC) transfusion during operation.Conclusions: The aortic balloon occlusion technique, as a perfusion strategy during operation, could alleviate postoperative complication. This method deserves further attention in future clinical practice for its value in treating patients with higher operative risks.  相似文献   

2.
BACKGROUND: Intravenous administration of vasopressin during cardiopulmonary resuscitation (CPR) has been shown to improve myocardial and cerebral blood flow. Aortic balloon occlusion during CPR may also augment myocardial and cerebral blood flow and can be used as a central route for the administration of resuscitative drugs. We hypothesized that, as compared with intravenously administered vasopressin, the administration of this drug above the site of an aortic balloon occlusion would result in a greater increase in cerebral perfusion and oxygenation during CPR and after restoration of spontaneous circulation (ROSC). METHODS: Twenty piglets were subjected to 5 min of ventricular fibrillation followed by 8 min of closed-chest CPR and were treated with 0.4 U kg(-1) boluses of vasopressin intravenously (the IV-vasopressin group with sham aortic balloon) or above the site for an aortic balloon occlusion (the balloon-vasopressin group). The aortic balloon catheter was inflated in the latter group 1 min after commencement of CPR and was deflated within 1 min after ROSC. Systemic blood pressures, cerebral cortical blood flow, cerebral tissue pH and PCO2 were monitored continuously and the cerebral oxygen extraction ratio was calculated. RESULTS: During CPR, arterial blood pressure and cerebral perfusion pressure were greater in the balloon-vasopressin group, as compared with the IV-vasopressin group. These pressures did not differ between the groups after ROSC. Cerebral cortical blood flow was not significantly greater in the balloon-vasopressin group during CPR, whereas significantly higher cortical blood flow levels were recorded after ROSC. Cerebral tissue pH decreased in the IV-vasopressin group during the post-resuscitation hypoperfusion period. In contrast, decreasing pressures during the hypoperfusion period did not result in increasing tissue acidosis in the balloon-vasopressin group. CONCLUSIONS: During CPR, intra-aortic vasopressin combined with aortic balloon occlusion resulted in significantly greater perfusion pressures but not in greater cerebral cortical blood flow. After ROSC, however, a greater increase in cortical blood flow was recorded in the balloon-vasopressin group, even though the aortic balloon was deflated and perfusion pressures did not differ between the groups. This suggests that vasopressin predominantly gives vasoconstrictive effects on cerebral cortical vessels during CPR, but results in cerebral cortical vasodilatation after ROSC.  相似文献   

3.
Massive intraabdominal hemorrhage sometimes requires urgent hemostatic surgical intervention. In such cases, its rapid stabilization is crucial to reestablish a general hemodynamic status. We used an aortic occlusion balloon catheter in patients with massive intraabdominal hemorrhage occurring after hepatopancreato-biliary surgery. An 8-French balloon catheter was percutaneously inserted into the aorta from the femoral artery, and the balloon was placed just above the celiac artery. Fifteen minutes inflation and 5 minutes deflation were alternated during surgery until the bleeding was surgically controlled. An aortic occlusion balloon catheter was inserted on 13 occasions in 10 patients undergoing laparotomy for hemostasis of massive hemorrhage. The aorta was successfully occluded on 12 occasions in nine patients. Both systolic pressure and heart rate were normalized during aortic occlusion, and the operative field became clearly visible after adequate suction of leaked blood. Bleeding sites were then easily found and controlled. Hemorrhage was successfully controlled in 7 of 10 patients (70%), and they were discharged in good condition. The aortic occlusion balloon catheter technique was effective for easily controlling massive intraabdominal bleeding by hemostatic procedure after hepato-pancreato-biliary surgery.  相似文献   

4.
BACKGROUND: Carotid endarterectomy (CEA) is the standard of care for patients with high-grade carotid artery stenosis who are acceptable surgical candidates. Focal occlusive lesions of the origin of aortic arch vessels can be effectively and safely treated with balloon angioplasty and primary stenting. The purpose of this study was to retrospectively review results of carotid endarterectomy for high-grade carotid bifurcation stenosis combined with intraoperative retrograde transluminal angioplasty and primary stenting of a hemodynamically significant stenosis at the origin of a proximal ipsilateral aortic arch vessel. METHODS: Between October 1994 and August 1998, 592 patients underwent CEA. Six patients were found to have hemodynamically significant tandem lesions affecting one of the aortic arch vessels and the ipsilateral ICA for an overall incidence of 1%. Age ranged from 63 to 78 years (mean 74.7). Four of 6 (67%) patients had asymptomatic lesions, and 2 of 6 (33%) had symptoms of cerebral ischemia. Five patients had tandem lesions affecting the proximal left common carotid artery and the left ICA. One patient had a tandem lesion affecting the innominate artery and the right ICA. Carotid duplex imaging and arch and cerebral arteriography was performed in all six patients. Arteriography confirmed high-grade stenoses in both the ICA and ipsilateral proximal aortic arch vessel. The range of stenoses in the ICA was 70 to 95% (mean 80.8%) measured arteriographically. The range of stenoses at the origin of the aortic arch vessels was 75-90% (mean 79.2%). All six patients underwent combined retrograde transluminal balloon angioplasty and primary stenting of the ipsilateral CCA or innominate artery with temporary occlusion of the ICA for cerebral protection. The endovascular procedure was then followed with standard surgical endarterectomy using an inline shunt. RESULTS: All six procedures were successfully completed. There were no periprocedural strokes or other morbidities. Follow-up ranged from 6 to 43 months (mean 23.6) and showed no evidence of recurrent stenosis by carotid duplex imaging. No TIAs or strokes related to the surgically corrected lesions were noted during the follow-up period. One patient suffered a right hemispheric stroke secondary to a high-grade right carotid stenosis which occurred two months after her procedure surgically correcting tandem lesions on the opposite side. CONCLUSIONS: Carotid endarterectomy with balloon angioplasty and primary stenting of an ipsilateral hemodynamically significant aortic arch trunk vessel stenosis can be safely and successfully accomplished and avoids the need for an intra/extrathoracic bypass procedure.  相似文献   

5.
目的 探讨腹主动脉球囊阻断在植入型凶险型前置胎盘产妇剖宫产术中的临床应用效果。方法 回顾性分析18例接受腹主动脉球囊阻断联合剖宫产手术的植入型凶险型前置胎盘产妇的临床资料。记录术中出血量、输血量、球囊阻断有效率、总阻断时间、子宫切除情况及并发症等。结果 18例产妇均成功行腹主动脉球囊阻断辅助剖宫产术,技术成功率为100%(18/18)。剖宫产术中平均出血量为(1 276.11±761.59)ml,平均输入悬浮少白红细胞(2.86±1.51)U,无一例因出血而死亡。球囊阻断有效率100%(18/18),球囊有效阻断时间(24.06±26.19)min。4例(4/18,22.22%)产妇在胎儿娩出后行子宫切除术,均由于胎盘植入严重,甚至广泛侵犯宫颈、膀胱、肠道。剖宫产前后产妇均未出现与球囊阻断、介入栓塞相关的严重并发症。结论 对于凶险型前置胎盘产妇,腹主动脉球囊可以有效阻断血流,减少剖宫产术中出血量、输血量,降低子宫切除率及手术风险。  相似文献   

6.
We report on a novel approach to correcting iliac artery occlusions caused by aortic counterpulsation. Two patients who had leg ischemia after retrieval of an intraaortic balloon pump underwent angiograms that showed occlusion of the right external iliac artery because of dissection (one case) or thrombosis (one case). Percutaneous self-expandable stents were implanted in the occluded vessels, and they fully restored normal iliac patency with no complications and satisfactory midterm follow-up results. We conclude that iliac artery occlusion induced by aortic counterpulsation can be safely treated by implanting self-expandable stents in cases of acute iatrogenic dissection. (J Vasc Surg 1996;24:279-83.)  相似文献   

7.
BACKGROUND: Our aim was to determine whether suprarenal fixation in endografts compromises renal artery (RA) flow and whether subsequent RA intervention is precluded by the stent struts. METHODS: Prospectively acquired data from 104 patients with endovascular aneurysm repair (EVAR) of an abdominal aortic aneurysm using the Zenith endograft (Cook, Inc., Bloomington, IN) were analyzed. The Zenith device uses a 26-mm, uncovered, barbed Z stent for suprarenal function. RESULTS: No RA stenosis, occlusion, or infarction resulted from the suprarenal stent. In 3 of 104 (2.9%) patients, RA compromise (2 stenoses, 1 occlusion) was caused by impingement of graft material on the lowermost RA. The 2 RA stenoses were stented successfully at 1 and 7 months post-EVAR. Six of 104 (5.8%) patients developed late stenoses unrelated to the endograft: all were stented successfully from 19 to 36 months after EVAR. One patient with severe RA stenosis had balloon angioplasty pre-EVAR and then was stented electively 6 weeks post-EVAR. CONCLUSIONS: Our data show that the suprarenal fixation of the Zenith aortic endograft does not cause RA stenosis, occlusion, or infarction, nor does it preclude post-EVAR renal artery intervention.  相似文献   

8.
进行骶尾部肿瘤根治手术时常常会出现危及生命的大出血。当前,有效、安全地控制这类出血仍是一个难题。在此我们报道在骶尾部肿瘤切除手术中应用球囊间歇阻塞腹主动脉远端来控制出血的一种方法。球囊管由股动脉插入,并进入腹主动脉。操作中,通过比较双侧脚趾的氧饱和度信号和超声定位来引导和确保球囊进入腹主动脉中肾动脉远端的位置。腹主动.脉内血流每阻断60分钟就开放10分钟。在进行骶尾部肿瘤切除手术的5例患者使用球囊阻塞后,失血量均小于300ml,手术时间短于2小时。手术后患者的肾脏、盆腔脏器以及下肢功能未出现明显改变。故经皮主动脉球囊阻塞术可对骶尾部肿瘤切除手术中出血进行有效而安全的控制。  相似文献   

9.
Radical sacral surgery can be associated with life-threatening blood loss. Effective and safe methods for controlling this blood loss remain elusive. We here report the use of an inflatable sizing balloon to intermittently occlude the distal abdominal aorta and control blood loss during sacral tumor resections. The balloon catheter was introduced into the abdominal aorta via the femoral artery. Pulse oxygen saturation signals from bilateral toes and ultrasonography were used to guide and confirm the location of the balloon in the abdominal aorta and distal to the renal arteries. The balloon was deflated for 10 min after each 60 min occlusion period. In five patients undergoing sacral tumor resection, the estimated blood loss when using balloon occlusion was <300 mL, and surgical duration was <2 h. No significant change in kidney, pelvic organ, and lower extremity function was found after the surgeries. Percutaneous aortic balloon occlusion can provide safe and effective control of blood loss during sacrococcygeal tumor resection.  相似文献   

10.
Balloon occlusion arteriography was performed in 38 lower limbs; reactive hyperemic arteriography was also performed in 16 of these limbs. To assess the safety and utility of this technique the balloon occlusion arteriograms of all 38 patients were reviewed retrospectively by a vascular surgeon and vascular radiologist who were unaware of the patient's identity and ultimate treatment. After the arteriograms were reviewed and the outflow vessels identified, a decision was made regarding operability and optimal recipient vessel for distal bypass. Twenty-two of the 38 patients underwent balloon occlusion arteriography only, and 21/22 (95.5%) of these patients only had studies deemed adequate for surgical planning. Twelve of the 16 (75%) patients underwent both reactive hyperemic arteriography and balloon occlusion arteriography; potential distal outflow vessels not seen on reactive hyperemic arteriograms were observed on balloon occlusion arteriograms. In only 4/16 (25%) patients the balloon occlusion arteriograms did not yield additional information. No complications were associated with this technique. Approximately 8.5 g of iodine per run is used for balloon occlusion arteriography compared with approximately 37 g of iodine per run for reactive hyperemic arteriography. Balloon occlusion arteriography is a safe and accurate adjunctive technique that can be used when identification of lower limb vessels is critical.Presented at the Seventeenth Annual Meeting of the Peripheral Vascular Surgery Society, Chicago, Ill., June 7, 1992.  相似文献   

11.
The technique of open distal anastomosis or application of aortic balloon occlusion catheter designed to occlude the descending thoracic aorta have been used in 33 and 19 patients, respectively, to control bleeding during the procedure of distal anastomosis for complete aortic arch replacement with a prosthetic graft. These two techniques allowed us a simple approach to the lesion and the avoidance of clamp injury to the fragile aortic tissue. Open distal anastomosis was applied for 91% patients of operated aortic dissection and all emergent cases, it’s duration ranged from 10 to 110 minutes with an average of 58 minutes under 18.2°C of lowest esophageal temperature. On the other hand, aoritc occlusion balloon was inserted for mainly true aortic aneurysm patients without an emergency, and helped to maintain the perfusion pressure on a lower part of body around 50 mmHg by the 1550 ml/min in an average of perfusion flow femoral artery under 21.2°C of temperature. The difference of postoperative renal and liver function evaluated by serum enzyme levels of total bilirubin, GOT, GPT, LDH, creatinine and BUN did not reach to statistical significance between the patients using open distal anastomosis and balloon occlusion, however, the incidence of postoperative complication including either renal, liver dysfunction, abdominal problem or paraplegia was significantly higher in the patient group with open distal tecnhipue. Either open distal anastomosis or aortic balloon occlusion tecnhique would be appropriately selected according to the patient’s characteristics or the condition of aortic disease to be operated.  相似文献   

12.
A valveless, single-orifice polyurethane ventricle with a maximum stroke volume of 60 mL was implanted on the brachiocephalic artery just above the aortic arch in sheep (n = 14) to act as an extraaortic counterpulsation device. In parallel, an intraaortic balloon was placed in the descending thoracic aorta. Both devices were pneumatically driven with an intraaortic balloon pump console that was gated by the electrocardiogram to provide aortic diastolic augmentation at a stroke volume of 40 mL. To compare the efficacy of counterpulsation for each device during severe cardiac failure, biventricular block was induced by continuous infusion of esmolol (100 to 600 micrograms.kg-1.min-1), titrated to reduce aortic flow and pressure to less than 75% of baseline. Pulsatile coronary and aortic flows were recorded with ultrasonic flow probes placed around their respective vessels. Aortic root and left ventricular pressures were recorded using micromanometers. The enhancement of hemodynamic variables for both devices were compared for optimal timing conditions, which were defined as inflation set just before the dicrotic notch and deflation bordering on isovolumetric systole. The extraaortic counterpulsation device was able to significantly augment aortic and coronary flows while simultaneously decreasing left ventricular tension time index and aortic end-diastolic pressure (p less than 0.02). The intraarotic balloon pump was able to significantly reduce only tension time index (p less than 0.002) to a lesser extent that the extraaortic counterpulsation device. All analysis was performed with the paired-samples t test. The extraaortic counterpulsation device greatly improves the myocardial oxygen supply-consumption ratio of the left ventricle by increasing diastolic coronary flow and reducing left ventricular wall tension during systole.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

13.
Spinal cord hypoperfusion injury is a devastating complication of cross-clamping the proximal thoracic aorta. The collateral circulation around the cross-clamp is generally poorly developed, and the run-off is immense, resulting in extremely low thoracic aortic and spinal cord perfusion pressures. The authors postulated that balloon occlusion of the abdominal aorta might confine this reduced collateral flow around the cross-clamp to the thoracic aorta. In 8 of 16 dogs subjected to aortic cross-clamping of the aorta just beyond the arch vessels, the abdominal aorta was also occluded by a balloon. Thoracic aortic pressure and spinal cord perfusion pressure were significantly higher in the animals with aortic balloon occlusion than in those without balloon occlusion (77 +/- 8 mm Hg versus 26 +/- 1 mm Hg, p less than 0.01, and 67 +/- 8 mm Hg versus 18 +/- 2 mm Hg, p less than 0.01, at 10 minutes after cross-clamping). Abdominal aortic balloon occlusion increases thoracic aortic pressure after the aorta is cross-clamped proximally. Further studies are necessary in primates to assess the effect of this procedure in spinal cord perfusion and the rate of paraplegia.  相似文献   

14.
Acute aortic occlusion is a rare but devastating complication of intra-aortic balloon pumping. Prompt diagnosis of aortic occlusion and immediate therapeutic decision making are keys for saving patients in such cases. We describe a 72-year-old man who underwent emergency surgical removal of a thrombus and aortoiliac bifurcated grafting for acute aortic occlusion after withdrawal of the intra-aortic balloon pumping catheter. The presence of a small unrecognized abdominal aortic aneurysm was considered to be the cause of thrombosis in this patient. Ultrasonographic screening for an abdominal aortic aneurysm is recommended for patients who require intra-aortic balloon pumping support.  相似文献   

15.
OBJECTIVES: to evaluate the results of our early experience with a percutaneous closure device for aortic aneurysm repair and to identify device related and patient related factors leading to procedure failure. METHODS: eighty-two percutaneous closures in forty-four patients was performed using the 10F Prostar XL Percutaneous Vascular Surgery device during the repair of 1 iliac, 1 thoracic and 42 abdominal aortic aneurysms. RESULTS: successful closure was achieved in 70 access sites (85%) with 12 sites requiring conversion to an open groin incision. The reasons for failure include difficult device introduction due to a tortuous iliac, deflection of needles due to previous scar, femoral artery occlusion and failure of the device to close the arteriotomy. There was one intraoperative death from retroperitoneal haemorrhage and another patient developed a pseudoaneurysm at the cannulation site. CONCLUSIONS: use of the percutaneous closure device requires very careful patient selection. Preoperative radiological assessment of the ilio-femoral vessels is vital to assess for cacification and tortuosity. High device failure rates can be expected from obese patients and those with scarred groins. When difficulty is encountered during the procedure, there should be a low threshold for conversion to an open groin incision. The device and the method of introduction can be further improved to address some of these issues.  相似文献   

16.
目的探讨对胎盘植入患者剖宫产术前行腹主动脉球囊预置阻断术的临床疗效。方法回顾性分析23例剖宫产术前接受腹主动脉球囊预置阻断术的患者资料,评价治疗效果。结果 23例平均术中出血1300ml,平均术后24h阴道流血80ml。18例患者成功保留子宫;4例穿透性胎盘植入出现难治性出血接受子宫切除术,1例因胎盘穿透至膀胱接受子宫切除、膀胱修补、输尿管再植术。23例产后均未发生感染、晚期产后出血、下肢血栓等并发症。1胎为无生机儿,余22胎顺利出生。1例新生儿因严重缺氧、脑出血死亡。21名存活新生儿出生后42天门诊随访检查均未见异常。结论腹主动脉球囊预置阻断术出血量少,有助于保留子宫,是胎盘植入患者剖宫产术前安全有效的治疗方法。  相似文献   

17.
OBJECTIVE: Postoperative neurologic deficits after thoracic aortic reconstruction vary widely. Our previous study showed that delayed ischemic preconditioning could prevent spinal cord injury caused by occlusion of the descending thoracic aorta in pigs. We investigated early ischemic preconditioning in the same model. METHODS: Twenty-eight pigs were divided into 4 groups: group 1 (n = 6) underwent a sham operation, group 2 (n = 6) underwent aortic occlusion for 20 minutes, group 3 (n = 8) underwent aortic occlusion for 35 minutes, and group 4 (n = 8) underwent aortic occlusion for 20 minutes and underwent aortic occlusion 80 minutes later without hypotension for 35 minutes. Aortic occlusion was accomplished by using 2 balloon occlusion catheters placed fluoroscopically at T6 to T8 above the diaphragm and at the aortic bifurcation. Neurologic evaluation was performed by an independent observer according to the Tarlov scale (0-4). The lower thoracic and lumbar spinal cords were harvested at 120 hours and examined histologically with hematoxylin-and-eosin stain. Histologic results (number of neurons and grade of inflammation) were scored (0-4) and were similarly analyzed. Statistical analysis was by means of the Kruskal-Wallis test. RESULTS: Group 4 had a better neurologic outcome at 24, 48, and 120 hours in comparison with group 3 (P <.001). The histologic changes were proportional to the neurologic test scores, with the more severe and extensive gray matter damage in animals of group 3 (number of neurons, P <.001; grade of inflammation, P <.001). CONCLUSION: Early ischemic preconditioning without hypotension protects against spinal cord injury after aortic occlusion, as confirmed by using the Tarlov score and histopathology.  相似文献   

18.
BACKGROUND: Interruption of antegrade cerebral perfusion results in transient neurologic intolerance in some patients undergoing carotid angioplasty and stenting (CAS). This study sought to evaluate factors that contributed to the development of cerebral ischemia during PercuSurge balloon occlusion and techniques used to allow successful completion of the CAS procedure. METHODS: The PercuSurge occlusion balloon was used in 43 of 165 patients treated with CAS for high-grade stenosis (mean stenosis, 90%). All 43 patients were at increased risk for endarterectomy (7 restenosis, 3 irradiation, 3 contralateral occlusion, and 30 Goldman class II-III); 20% were symptomatic. Symptoms of cerebral hypoperfusion during temporary occlusion of the internal carotid artery occurred in 10 of 43 and included dysarthria (7/10), agitation (6/10), decreased level of consciousness (5/10), and focal hemispheric deficit (3/10). An incomplete circle of Willis or contralateral carotid artery occlusion, or both, was present in 8 of 10 patients. Symptoms resulting from PercuSurge balloon occlusion were managed by balloon deflation with or without evacuation of blood from the internal carotid artery using the Export catheter. All symptoms resolved completely without deficit after deflation of the occlusion balloon. RESULTS: The development of neurologic symptoms after initial PercuSurge balloon inflation and occluded internal carotid artery flow was associated with a decrease in the mean Glasgow Coma Scale (GCS) from 15 to 10 (range, 9 to 14); the GCS returned to normal after occlusion balloon deflation and remained normal during subsequent reinflation. The mean time to spontaneous recovery of full neurologic function was 8 minutes (range, 4 to 15 minutes). No thrombotic or embolic events were present on cerebral angiography or computed tomography scan. Balloon reinflation was performed after a mean reperfusion interval of 10 minutes after full neurologic recovery (range, 4 to 20 minutes). The mean subsequent procedure duration was 11.9 minutes (range, 6 to 21 minutes). No recurrence of neurologic symptoms occurred when the occlusion balloon was reinflated. All 10 patients underwent successful CAS without occlusion, dissection, cerebrovascular accident, or death. CONCLUSION: Several factors may contribute to the development of neurologic intolerance during CAS with balloon occlusion. Elucidation of the protective cellular mechanisms that invoke ischemic tolerance after the initial transient ischemic event may enable CAS with embolic protection in patients who cannot tolerate initial interruption of antegrade cerebral perfusion.  相似文献   

19.
Study Objective: To describe the hemodynamic consequences of a regional chemotherapy procedure involving occlusion of the thoracic aorta and inferior vena cava (IVC) by intraluminal balloons.

Design: Prospective study.

Setting: Operating rooms of an academic hospital.

Patients: 10 patients with inoperable intraabdominal malignancy.

Interventions: After the induction of general anesthesia and the insertion of a pulmonary artery catheter the patients underwent the regional chemotherapy procedure

Measurements and Main Results: Occlusion of the thoracic aorta induced an increase in blood pressure (BP) and systemic vascular resistance (SVR) (41% ± 8% and 80% ± 15% from baseline, respectively), and a 30% ± 7% decrease in cardiac output (CO). After aortic balloon deflation at the end of the procedure, we observed a decrease in BP to baseline values, decrease in SVR (to 62% ± 12% below baseline), and increase in CO (to 80% ± 15% above baseline). Those changes resemble those described during vascular surgery. Isolated occlusion of the IVC before aortic occlusion caused hemodynamic deterioration in only three of 10 patients, suggesting incomplete obstruction or collateral blood flow in others. Occluding the IVC while the aorta was occluded, caused minimal hemodynamic changes.

Conclusions: Independent inflation of the IVC balloon should not be performed routinely because of possible unpredicted hemodynamic instability. Inferior vena cava occlusion should always be performed after complete aortic occlusion, because it is then that it produces negligible hemodynamic consequences. It is possible that a better assessment of IVC occlusion after balloon inflation needs to be done by contrast injection to prevent a possible leak of chemotherapeutic drugs.  相似文献   


20.
This study was performed to evaluate the efficacy of a balloon-expandable Palmaz stent common iliac artery occluder device for endovascular stent-graft repair of aortoiliac aneurysms. Eighty-four patients (79 men, 5 women; age range 60-95 yr; mean age, 76 yr) with aortoiliac aneurysms underwent endovascular stent-graft repair. The repair consisted of a stent-graft extending from the abdominal aorta to the iliac or common femoral artery, a cross-femoral bypass graft, and an endovascular arterial occluder device within the contralateral common iliac artery. The occluder device consisted of a 5-cm segment of 6-mm diameter polytetrafluoroethylene (PTFE) graft with a purse-string suture occluding the leading end and a Palmaz stent sutured to the trailing end. The occluder device was delivered through a 17F catheter via an arteriotomy. Eighty-three of the 84 patients received aortic endografts. In one case, infrarenal aortic rupture occurred during deployment of the aortic stent requiring conversion to an open surgical repair. Initial technical success for occluder device insertion was achieved in 78 of the remaining 83 patients. Failure to advance the occluder device delivery sheath through a diseased iliac artery occurred in one patient. Common iliac artery rupture occurred during balloon expansion and occluder device deployment in two patients. Two patients required additional coil embolization of the common iliac artery adjacent to the occluder device at the time of stent-graft insertion to correct incomplete iliac occlusion. Delayed occluder device-related complications included one patient with a postoperative iliac endoleak who required percutaneous coil embolization and one patient with a postoperative iliac endoleak in whom a contained aortic aneurysm rupture developed that was treated by surgical ligation of the common iliac artery. Use of the Palmaz stent-based iliac artery occluder device is an effective technique to induce common iliac artery thrombosis to facilitate endoluminal stent-graft aneurysm repair.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号