首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 156 毫秒
1.
[目的]通过尸体标本实验的方法探讨个体化导航模板辅助胸椎椎弓根螺钉置入的准确性及可行性.[方法]对6具胸椎尸体标本进行CT扫描,根据CT扫描资料,利用逆向工程原理及快速成型技术设计制造出个体化导航模板,利用个体化导航模板在尸体标本上辅助置入胸椎椎弓根螺钉,所有螺钉的置入由同一位具有腰椎椎弓根螺钉置钉经验但无胸椎椎弓根螺钉置钉经验的骨科医师进行操作,随后采用大体解剖的方法肉眼观察置钉的准确性;并根据螺钉是否穿破椎弓根、穿出距离及穿破方向进行分级.[结果]共设计制作了72个个体化导航模板辅助置入胸椎椎弓根螺钉144枚,132枚(91.7%)螺钉完全在椎弓根内;12(8.3%)枚螺钉穿破椎弓根,其中2枚螺钉穿破椎弓根内侧壁(穿破距离分别为0.6、0.8 mm),10枚螺钉穿破椎弓根外侧壁(9枚螺钉穿出距离<2 mm,1枚螺钉穿出距离为2.5 mm);没有椎弓根上方、下方及椎体前方穿破的螺钉.所有穿破椎弓根壁的螺钉均在安全可接受的范围内.[结论]快速成型个体化导航模板辅助胸椎椎弓根螺钉置入准确率高,对术者无特别的经验要求,手术操作简单、安全,可避免术中放射性损伤,为胸椎椎弓根螺钉的置入提供了一种新的可行方法,尤其适用于初学者.  相似文献   

2.
个体化导航模板辅助腰椎椎弓根螺钉置钉准确性实验研究   总被引:6,自引:1,他引:5  
目的:探讨个体化导航模板辅助腰椎椎弓根螺钉置入的准确性.方法:根据10具尸体腰椎(L1~L4)标本术前CT资料,利用逆向工程原理及快速成型技术设计制造出个体化导航模板,在尸体标本上进行个体化导航模板辅助腰椎椎弓根螺钉的置入手术,术后行CT断层扫描评价螺钉在椎弓根及椎体内的位置.结果:共应用40个个体化导航模板,辅助置入腰椎椎弓根螺钉80枚.CT扫描发现所有螺钉进钉点准确,进钉方向适当:全部螺钉均准确置入相应椎弓根及椎体内,无穿破椎弓根皮质及椎体前方的螺钉.结论:个体化导航模板辅助腰椎椎弓根螺钉置钉准确性高,操作简单,为腰椎椎弓根螺钉的准确置入提供了一种新的可供选择的方法.  相似文献   

3.
个体化导航模板在胸椎椎弓根螺钉置入中的初步临床应用   总被引:1,自引:0,他引:1  
目的:通过临床应用评价个体化导航模板辅助胸椎椎弓根螺钉置入的准确性和安全性。方法:2008年7月~2009年9月,对11例需要行胸椎椎弓根螺钉置入手术的患者(青少年特发性脊柱侧凸7例,先天性脊柱侧凸2例,胸椎结核后凸畸形1例,多发性胸椎骨折1例)术前根据CT三维重建图像利用计算机辅助设计及快速成型技术设计制作46个胸椎个体化导航模板,术中应用个体化导航模板辅助在T2~T12置入椎弓根螺钉92枚,术后CT扫描评价螺钉位置,记录有无与螺钉置入相关的并发症。结果:通过个体化导航模板辅助置入的92枚胸椎椎弓根螺钉中,83枚完全在椎弓根内,9枚穿破椎弓根壁(其中椎弓根内侧壁穿破2枚、椎弓根外侧壁穿破7枚),其中5枚螺钉因椎弓根宽度小于4mm(3.0~3.8mm)而采用椎弓根旁固定方法(椎弓根螺钉轻度穿破椎弓根外侧壁经胸肋关节内侧进入椎体),椎弓根壁非故意穿破率为4.3%,置钉准确率为95.7%,所有穿破椎弓根壁的螺钉的穿出距离均小于2mm,螺钉位置可接受率为100%。无与螺钉置入有关的神经、血管、内脏损伤等并发症的发生。结论:个体化导航模板辅助胸椎椎弓根螺钉置入的置钉准确率高,安全、可行。  相似文献   

4.
目的 :探讨个性化导航模板辅助儿童颈椎椎弓根螺钉置入的可行性及准确性,并与徒手置钉进行对比。方法:选取儿童尸体4具,男女各2具,年龄6~9岁。随机分为2组,均行颈椎椎弓根螺钉置入术。徒手置钉组(A组)行徒手置钉;个性化导航模板辅助下置钉组(B组)依据颈椎CT扫描资料,利用计算机辅助及快速成型技术设计并制作出相应颈椎椎弓根螺钉置入个性化导航模板,行该模板辅助下置钉。置钉后行颈椎CT扫描评价两种置钉方法的置钉成功率及优级率并行统计分析。结果:A组共置入28枚螺钉,寰椎置入4枚螺钉,其中良级3枚、差级1枚;枢椎置入4枚螺钉,其中优级2枚、良级2枚;下颈椎(C3~C7)置入20枚螺钉,其中优级9枚、良级5枚、差级6枚。B组共置入28枚螺钉,寰椎置入4枚螺钉,其中良级2枚、差级2枚;枢椎置入4枚螺钉,其中优级3枚、良级1枚;下颈椎置入20枚螺钉,其中优级16枚、良级3枚、差级1枚。两组上颈椎的置钉成功率及优级率因样本数太少未进行统计学比较;两组下颈椎置钉的成功率及优级率均有统计学差异(P<0.05)。结论 :个性化导航模板辅助儿童下颈椎椎弓根螺钉置入术具有较好的置钉成功率,该方法操作简单、易于掌握,充分体现了儿童置钉个性化原则。  相似文献   

5.
目的 研究数字化(3D)打印技术的个性化导航模板设计在胸椎和颈椎手术个性化置钉应用的准确性和安全性。方法 2014年7月至2014年11月,对7例需要行胸椎、颈椎椎弓根螺钉植入手术的患者术前通过CT扫描、Mimics软件三维重建建立三维仿真模型。并使用Geomagic软件设计最佳的内固定钉道,然后根据钉道设计导航模板,用3D打印机打印导航模板,用于手术时辅助置钉;术中辅助植入胸椎、颈椎椎弓根螺钉共24枚,术后CT扫描评价螺钉位置,记录有无与螺钉植入的相关并发症。结果 通过导航模板辅助植入的24枚椎弓根螺钉,23枚完全在椎弓根内,1枚穿破椎弓根外壁,穿出距离均小于1.2 mm,椎弓根穿破率为4%,植钉准确率为96%,螺钉位置可接受率为100%。无一例出现螺钉植入有关的神经、血管损伤等并发症。结论 3D打印个体化导航模板辅助胸椎、颈椎椎弓根螺钉植入的植钉准确性高、安全。  相似文献   

6.
目的 :通过3D打印技术及骨科数字化技术制作下颈椎前路椎弓根螺钉置钉导航模板,观察模板辅助下置钉的准确性。方法:选取正常成人颈椎湿性标本10具(男、女各5具),将椎前软组织剔除,采用64排薄层CT扫描后获取其DICOM格式数据,导入Mimics软件后三维建模并为颈前路椎弓根螺钉选取理想钉道,设计建立螺钉导航模板后导出其STL数据,通过3D打印机快速打印成型。在导航导板引导下进行下颈椎前路椎弓根螺钉置钉,通过X线及CT评价螺钉的准确性。结果:10具尸体分别于C3~T1每节段置入2枚螺钉,共计120枚,根据螺钉的位置将其分为4级:0级,螺钉完全在椎弓根内,共115枚;1级,螺钉穿破椎弓根皮质,穿出部分小于螺钉直径的25%,1枚;2级,螺钉穿破椎弓根皮质,穿出部分为螺钉直径的25%~50%,3枚;3级,螺钉穿出椎弓根部分大于螺钉直径的50%,1枚。5枚穿破椎弓根皮质者2枚穿破椎弓根内侧皮质,3枚穿破外侧皮质,总体准确性为95.8%。结论:在湿性尸体颈椎标本上应用3D打印及骨科数字化技术制作的导航模板辅助行下颈椎前路椎弓根螺钉置钉的准确性高,为临床应用提供了依据。  相似文献   

7.
《中国矫形外科杂志》2014,(20):1880-1884
[目的]探讨一种基于三维打印成型技术制备个体化下颈椎椎弓根螺钉导航模板的可行性,并对该方法辅助置钉的准确性进行评估。[方法]选取10具成人尸体的颈椎标本,行CT扫描后将原始数据导入Mimics软件,对C37节段行选择性重建,设计与其椎板和棘突相贴合的阴模,利用三维打印技术成型。基于目标椎体三维模型,直视下徒手将阴模制成具有双侧椎弓根螺钉钉道的导航模板,并在其辅助下于各椎体标本置入双侧椎弓根螺钉。术后再次行CT扫描评估螺钉位置。[结果]剔除骨性结构不完整的标本后,共制作62个下颈椎导航模板,辅助置入椎弓根螺钉124枚。CT扫描轴位图像显示121枚螺钉完全位于椎弓根内,3枚部分穿破椎弓根壁;矢状位图像提示除1枚螺钉误入椎间孔外,余钉位准确。[结论]本研究结果表明,基于CT图像,使用Mimics软件能够精确重建下颈椎各节段椎体及其附属结构,并建立其对应阴模。利用三维打印模型所设计的个体化导航模板,辅助置钉准确性高、操作简单,为下颈椎椎弓根螺钉的精确置入提供了一种可供选择的新方法。  相似文献   

8.
目的 :评价个体化导航模板辅助颈椎椎弓根螺钉置入的准确性和安全性。方法 :2010年8月~2013年8月,对25例需要行颈椎椎弓根螺钉内固定的患者术前行64排螺旋CT连续扫描,计算机重建颈椎三维模型、设计颈椎椎弓根的最佳进钉通道,获取每个颈椎椎板的解剖形态,设计与颈椎椎板吻合的反向模板,并模拟螺钉的最佳进钉通道,形成单侧定位导向孔的导航模板。利用3D打印技术打印颈椎模型和导航模块,通过术前模拟置钉测量出每个椎弓根的螺钉通道长度及椎弓根宽度,术中采用导航模板辅助置入椎弓根螺钉,术后行CT扫描评价螺钉位置,记录有无与螺钉置入相关的并发症。结果:利用导航模板辅助置入颈椎椎弓根螺钉共164枚,其中152枚完全在椎弓根内,4枚螺钉穿破椎弓根内侧皮质,8枚螺钉穿破椎弓根外侧皮质,无椎弓根上方、下方穿破的螺钉,未发现与置钉相关的椎动脉、神经根和颈髓等损伤的症状。结论:个体化导航模板辅助颈椎椎弓根螺钉置入可以提高置钉的准确率,增加颈椎手术的安全性。  相似文献   

9.
目的探讨利用激光选区熔化成型技术制作金属材质手术导航模板的可行性及准确性。方法选取新鲜成人正常颈椎标本(C_(1~6))8具,随机分为金属导航模板组(金属组)和树脂导航模板组(树脂组),每组4具。所有标本均通过CT扫描获取dicom格式数据,将数据导入计算机后,根据分组设计并制作金属或树脂颈椎椎弓根螺钉导航模板。2组分别在相应导航模板辅助下置入椎弓根螺钉,行CT钉道扫描,对2种模板的准确性和安全性进行评价。结果8具标本分别于C1~6的每个节段置入2枚螺钉,每组48枚,共计96枚。金属组置钉准确率为87.5%(42/48),树脂组为70.8%(34/48),2组比较差异有统计学意义(P 0.05)。金属组置钉安全率为97.9%(47/48),树脂组为93.8%(45/48),2组比较差异无统计学意义(P 0.05)。结论利用激光选区熔化成型技术制作的改良金属个性化导航模板具有良好的置钉准确性和安全性,为颈椎椎弓根螺钉的精确置入提供了一种新的方法。  相似文献   

10.
《中国矫形外科杂志》2019,(24):2247-2251
[目的]比较Renaissance机器人系统辅助椎弓根螺钉置入与徒手椎弓根螺钉置入在腰椎翻修手术中的安全性及准确性。[方法]回顾性分析2018年1月~2018年12月在本院行腰椎后路翻修手术的病例69例,其中使用Renaissance机器人系统辅助椎弓根螺钉置入共31例,使用传统徒手椎弓根螺钉置入38例。记录临床资料,并根据术后CT对螺钉精度进行Gertzbein Robbins分级,比较螺钉置入准确性。[结果]两组患者手术时间、术后出血量及手术相关并发症等差异无统计学意义(P0.05)。机器人组术中出血量、术中透视次数显著少于徒手组(P0.05)。机器人辅助组共置入螺钉152枚,术后CT评估显示:A级置钉137枚,B级置钉11枚,C级置钉4枚,没有D、E级置钉,置钉准确率97.37%。徒手组共置入螺钉194枚,术后CT评估显示:A级置钉129枚,B级置钉48枚,C级置钉15枚,D级置钉2枚,没有发现E级置钉,置钉准确率91.24%。在螺钉精度分级及螺钉准确性方面,机器人组优于徒手组,差异具有统计学意义(P0.05)。[结论]与徒手置钉技术相比,Renaissance机器人系统辅助椎弓根螺钉置入在腰椎翻修手术中具有置钉精度高、且术中出血及术中透视次数少的优势。  相似文献   

11.
目的探讨3D打印模板导航经皮椎弓根螺钉置钉在经椎间孔腰椎椎间融合术(TLIF)治疗腰椎椎管狭窄症中应用的可行性、准确性和安全性。方法回顾性分析2016年1月—2017年3月本院采用TILF治疗的单节段腰椎椎管狭窄症患者的临床资料,选取10例应用3D打印模板导航置钉的患者作为试验组,选取一般情况相似的10例作为对照组。试验组下肢无临床表现侧在3D打印模板导航下置入螺钉(模板侧),下肢有临床表现侧切开后经Wiltse入路顺导针置入螺钉(穿刺侧);对照组采用传统徒手法置入椎弓根螺钉。记录患者手术时间、出血量、透视时间及次数、螺钉置入的准确性及脊髓、神经损伤并发症发生情况。结果试验组手术时间、出血量少于对照组,差异有统计学意义(P0.05)。试验组模板侧透视时间及次数少于穿刺侧及对照组,差异有统计学意义(P0.05);而穿刺侧与对照组相比差异无统计学意义(P0.05)。试验组无2级螺钉,对照组2级螺钉有4枚。0级螺钉比例,试验组两侧均优于对照组,差异有统计学意义(P0.05);试验组两侧差异无统计学意义(P0.05)。所有患者均无脊髓、神经损伤等并发症发生。结论 3D打印模板导航经皮椎弓根螺钉置钉应用于TLIF治疗腰椎椎管狭窄症是可行的。虽然应用过程中需要注意避免皮肤移动、体位变化对置钉准确性的影响,但仍是一种新的、可选择的微创置钉技术。  相似文献   

12.
导航系统辅助下颈椎椎弓根螺钉置钉准确性的实验研究   总被引:2,自引:0,他引:2  
目的:评价导航系统辅助下颈椎(C3~C7)椎弓根螺钉内固定置钉的准确性.方法:将32具成人尸体颈椎标本随机分为4组,分别采用盲法、透视法、透视导航法和CT导航法进行下颈椎椎弓根螺钉置入.术后采用标本大体解剖观察的方法评价置钉准确性.分优(螺钉完全在椎弓根内)、可(仅有螺纹穿出,对周围组织无损伤)和差(螺钉明显穿出)进行统计.结果:共置入螺钉318枚.盲法80枚,平均手术时间27min,优29枚(36 3%)、可21枚(26.3%)、差30枚(37.5%);透视法78枚(有1例C4、C5右侧椎弓根均细小,不能容纳3.5mm螺钉),平均手术时间112min,优35枚(44.9%)、可29枚(37.2%)、差14枚(17.9%);透视导航法80枚,平均手术时间69min,优34枚(42.5%),可36枚(45%),差10枚(12.5%);CT导航法80枚,平均手术时间98min,优70枚(87.5%)、可10枚(12.5%).各组间手术时间均有显著性差异(P<0.05),透视法与透视导航法的置钉准确率间无显著性差异,其余各组间均有显著性差异(P<0.05).结论:单纯根据术前影像结果盲法行下颈椎椎弓根螺钉内固定不安全.透视法和透视导航法可提高置钉准确性,但手术风险仍较大,透视导航法比透视法置钉的手术时间缩短.CT导航法并未比透视法增加手术时间,但置钉准确性显著提高.  相似文献   

13.
A simple and inexpensive method was developed to obtain a coaxial view of the pedicles to assist with screw insertion. The authors evaluated the accuracy of this device to place transpedicular vertebral screws in a human adult cadaver model. A dual radiation targeting system, a laser targeting system for fluoroscopically guided procedures, was developed to provide an accurate surface entry point and angle of approach to radiographic landmarks. After fluoroscopic cross-hair target localization of the coaxial view of the pedicle, X-ray radiation is turned off and the laser beam allows the surgeon to guide the screw through the pedicle. Nine cadaver spines were removed and mounted. Three surgeons, inexperienced in the technique of pedicle screw placement, fitted instruments to 184 pedicles between L5 and T5. A total of 83 lumbar and 101 thoracic pedicles underwent screw placement. After specimen dissection, the degree and location of any screw perforation were measured by direct inspection. Three screws perforated a pedicle, for an error rate of 1.6%. Two lumbar screws (2.4% error) and one thoracic screw (1% error) perforated the pedicle. No screw was more than 1 mm outside the pedicle. Five other screws, four in the thoracic spine and one in the lumbar spine (error rate of 2.7%) were directed too far laterally and perforated the lateral vertebral body. This low rate of pedicle wall cortical perforation by inexperienced surgeons compares favorably with much higher pedicle perforation rates by experienced surgeons when no imaging was used. In conclusion, this in vitro model using a dual radiation targeting system assisted with the accurate placement of transpedicular vertebral screws with minimal radiation exposure.  相似文献   

14.
目的 探讨快速成型技术佐助胸腰椎椎弓根螺钉置入的准确性和可靠性.方法 将患者分成两组,快速成型组26例,传统手法置钉组26例,由同一位医师分别采用快速成型模型佐助置钉法和传统手法置钉进行胸腰椎椎弓根螺钉置入.术后CT扫描比较两种方法的置钉准确性.结果 快速成型模型佐助置钉156枚,其中3枚穿破皮质,成功率98.08%,绝对风险率0.64%;传统手法置钉121枚,11枚穿破皮质,成功率90.91%,绝对风险率4.13%.两组病例均未出现神经血管损伤并发症,快速成型佐助置钉法准确率明显高于传统手法置钉,安全性提高,差异具有统计学意义(P<0.05).结论 快速成型模型佐助胸腰椎椎弓根置钉,可提高准确率和安全性,操作简单,符合个体化置钉,为胸腰椎椎弓根螺钉置入提供一种新方法.  相似文献   

15.
颈椎螺钉内固定技术凭借其高融合率、手术节段即刻固定及良好的矫形能力在临床上得到广泛应用。但由于解剖结构变异、椎弓根较细等原因,采用传统方法置钉难度较大,螺钉穿孔率较高,可引起神经血管损伤等严重并发症。近年来快速成型导航模板被报道应用于辅助颈椎螺钉置入,以提高螺钉置入的准确性。本文通过回顾及总结近20年来已发表关于导航模板辅助颈椎螺钉置入相关文献,系统介绍了导航模板的制作与使用方法、设计理念发展历程以及在颈椎手术中的应用现状。目前相关临床及尸体研究证实在颈椎手术中,使用快速成型导航模板辅助颈椎螺钉置入可降低螺钉穿孔率、术中电离辐射伤害及手术时间,值得在临床工作中推广应用。但是不同设计类型的导航模板的具体临床疗效没有很高的总结。因此,更多比较不同设计类型导航模板准确性与安全性的尸体及临床试验急需进行,以帮助临床医生选择合适的导航模板进行手术。  相似文献   

16.
目的通过应用三维重建技术辅助椎弓根螺钉的植入,评价其在上胸椎和颈椎置钉中的准确性和安全性。方法 2013年1月至2013年11月,对12例需要行上胸椎、颈椎椎弓根螺钉植入手术的患者术前通过Mimics三维重建图像设计进钉通道并获取相关参数,术中辅助植入上胸椎、颈椎椎弓根螺钉共50枚,术后CT扫描评价螺钉位置,记录有无与螺钉植入的相关并发症。结果通过Mimics三维重建植入的50枚椎弓根螺钉,47枚完全在椎弓根内,3枚穿破椎弓根壁,椎弓根穿破率为6%,植钉准确率为94%,所有穿破椎弓根壁的螺钉的穿出距离均小于2 mm,螺钉位置可接受率为100%。无一例出现螺钉植入有关的神经、血管损伤等并发症。结论 Mimics三维重建技术辅助上胸椎、颈椎椎弓根螺钉植入的置钉准确性高、安全,且明显缩短手术时间。  相似文献   

17.
Objective: To evaluate the accuracy of computer-assisted pedicle screw installation and its clinical benefit as compared with conventional pedicle screw installation techniques.
Methods: Total 176 thoracic pedicle screws placed in 42 thoracic fracture patients were involved in the study randomly, 20 patients under conventional fluoroscopic control (84 screws) and 22 patients had screw insertion under three dimensional (3D) computer-assisted navigation (92 screws). The 2 groups were compared for accuracy of screw placement, time for screw insertion by postoperative thincut CT scans and statistical analysis by χ^2 test. The cortical perforations were then graded by 2-mm increments: Grade Ⅰ (good, no cortical perforation), Grade Ⅱ (screw outside the pedicle 〈2 mm), Grade Ⅲ (screw outside the pedicle 〉2 mm).
Results: In computer assisted group, 88 (95.65%) were Grade Ⅰ (good), 4 (4.35%) were Grade Ⅱ (〈2mm), no Grade Ⅲ (〉2 mm) violations. In conventional group, there were 14 cortical violations (16.67%), 70 (83.33%) were Grade Ⅰ (good), Ⅱ (13.1%) were Grade Ⅱ (〈2 mm), and 3 (3,57%) were Grade Ⅲ (〉2 mm) violations (P〈0.001). The number (19.57%) of upper thoracic pedicle screws ( T1-T4 ) inserted under 3D computer-assisted navigation was significantly higher than that (3.57%) by conventional fluoroscopic control (P〈0.001). Average screw insertion time in conventional group was (4.56 ±1.03) min and (2.54 ± 0.63) min in computer assisted group (P〈0.001). In the conventional group, one patient had pleura injury and one had a minor dura violation.
Conclusions: This study provides further evidence that 3D computer-assisted navigation placement ofpedicle screws can increase accuracy, reduce surgical time, and be performed safely and effectively at all levels of the thoracic spine, particularly upper thoracic spine.  相似文献   

18.

Objective

Many thoracic pedicles are too small for the safe acceptance of a transpedicular screw. However, few studies have so far reported on the methods to select a proper pedicle screw size and to confirm the morphologic changes for such a small thoracic spine pedicle. The objective of this work was to determine the potential limits of a pedicle screw diameter for transpedicular screw placement in the thoracic spine.

Methods

T2–T9 vertebrae from eleven patients that underwent posterior thoracic instrumentation with the use of fluoroscopically assisted insertion method were analyzed. The outcome measures were the pedicle widths, the gap between the outer pedicle width and the selected pedicle screw diameter, and the penetration length of the pedicle screws using computed tomography. The screws were distributed into two groups according to the pedicle width and screw diameter, and the screw perforation rate of the two groups was compared. The relationships of the gap and the distance of the screw penetration were compared and investigated in regard to the pedicle screw diameter selection.

Results

A total of 16 screws demonstrated a smaller diameter than the inner pedicle widths, while 22 screws had a larger diameter than the inner pedicle widths. One screw (6.3%) perforated the pedicle cortex in the smaller screw group, and twelve screws (54.5%) perforated the pedicle cortex in the larger screw group (P?=?0.006). A linear regression analysis in the larger screw group revealed that when the gap was less than 0.5?mm, a risk of a pedicle wall violation was observed.

Conclusions

When the screws with a larger diameter than the inner pedicle width are selected, the screw perforation rate increases. Therefore, the size of the screw diameter must be at least 0.5?mm less than the outer pedicle width to ensure safe transpedicular screw placement.  相似文献   

19.
[目的]分析O-arm计算机辅助导航技术在脊柱椎弓根螺钉置入的准确性。[方法]回顾性分析2017年1月~2018年9月本院椎弓根螺钉置入患者575例,根据椎弓根螺钉置入方式不同,分为两组。导航组采用O-arm计算机辅助导航技术系统置入椎弓根螺钉233例,传统组采用传统徒手法置入椎弓根螺钉342例。行CT检查,依据Neo分型评估置钉准确性。[结果]导航组共置入1459枚椎弓根螺钉,其中C1~7置入222枚,T1~12置入535枚,L1~5置入652枚,S1置入50枚。每名患者置钉数量1~24枚,平均(6.26±3.77)枚。传统组共置入1724枚椎弓根螺钉,其中C1~7置入269枚,T1~12置入601枚,L1~5置入785枚,S1置入87枚。每名患者置钉数量1~20枚,平均(5.67±4.11)枚。导航组全部病例顺利完成手术,术中无血管、神经损伤等并发症,置钉安全率为100%,传统组有4例发生血管、神经损伤等并发症。所有患者术后进行12~24个月随访,随访过程均未发生不良事件。依据CT影像Neo分级标准,导航0型及1型椎弓根螺钉的成功置入率达98.01%,而传统组0型及1型椎弓根螺钉的成功置入率91.85%;两组间置入螺钉准确性的差异具有统计学意义(P<0.05)。[结论]与传统C臂X线机等徒手置钉方式相比,O-arm计算机辅助导航技术可提高脊柱椎弓根螺钉置入准确性,同时降低神经、血管等并发症的发生。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号