首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
《Acta orthopaedica》2013,84(5):509-514
Background and purpose — In the Netherlands about 40% of hip fractures are treated with a hemiarthroplasty (HA) or a total hip arthroplasty (THA). Although these procedures are claimed to have fewer complications than osteosynthesis (i.e., reoperation), complications still occur. Analyses of data from national registries with adequate completeness of revision surgery are important to establish guidelines to diminish the risk for revision. We identified risk factors for revision.

Patients and methods — All patients older than 50 years of age with a hip fracture treated with arthroplasty by orthopedic surgeons and registered in the (national) Dutch arthroplasty register (LROI) were included in the study. In this register, patient characteristics and surgical details were prospectively collected. Revision surgery and reasons for revision were evaluated. A proportional hazard ratio model for revision was created using competing risk analysis (with death as competing risk).

Results — 1-year revision rate of HA was (cumulative incidence function [CIF] 1.6% (95% CI 1.4–1.8) and THA 2.4% (CI 2.0–2.7). Dislocation was the most common reason for revision in both groups (HA 29%, THA 41%). Male sex, age under 80 years, posterolateral approach, and uncemented stem fixation were risk factors for revision in both THA and HA. THA patients with ASA classification III/IV were revised more often, whereas revision in the HA cohort was performed more often in ASA I/II patients.

Interpretation — After arthroplasty of hip fractures, both a posterolateral approach and an uncemented hip stem have higher risks for revision surgery compared with an anterolateral approach and an cemented stem.  相似文献   

2.
3.
4.
5.
Background and purpose — Femoral neck fractures (FNFs) are commonly treated with some kind of arthroplasty, but evidence on whether to use hemiarthroplasty (HA) or total hip arthroplasty (THA) is lacking. HA reduces the risk of dislocation, but may lead to acetabular erosion. THA implies longer surgery and increased bleeding. THA may result in better function and health-related quality of life, but evidence is contradictory. We compared HA and THA and in terms of revision, reoperation and death.

Patients and methods — Data were extracted from the Swedish Hip Arthroplasty Register for 11,253 patients with acute FNF receiving cemented HA or THA during 2008–2012. 2,902 patients with THA were matched by propensity score matching with as many patients with HA based on age, sex, BMI, and ASA classification. We used competing risks survival regression with reoperation or death and revision or death as endpoints.

Results — THA patients had significantly reduced risk of revision (absolute risk reduction 0.51; 95% CI 0.39–0.67) and reoperation (0.58; 0.46–0.74). THA was associated with an almost 50% reduced mortality (risk ratio as competing risk for reoperation 0.51; 0.46–0.57).

Interpretation — In our national register study of femoral neck fractures, THA had a lower risk than HA for further surgical procedures related to the hip. The reasons for lower mortality after THA are not known. Despite matching, there might be a selection of more healthy patients for this procedure, and other factors unknown to us, with or without relation to the choice of implant.  相似文献   


6.
《Acta orthopaedica》2013,84(4):312-317
Background and purpose — The use of trabecular metal (TM) cups for primary total hip arthroplasty (THA) is increasing. Some recent data suggest that the use of TM in primary THA might be associated with an increased risk of revision. We compared implant survival of Continuum acetabular cups with other commonly used uncemented cups.

Patients and methods — Data on 11,390 primary THAs with the Continuum cup and 30,372 THAs with other uncemented cups (reference group) were collected from the Finnish Arthroplasty Register. Kaplan–Meier survival estimates were calculated; the endpoint was revision for any reason, for infection, or for dislocation. Revision risks were assessed with adjusted Cox multiple regression models. A subgroup analysis on the use of neutral or elevated liners in the Continuum group was made.

Results — The 7-year survivorship of the Continuum group was 94.6% (95% CI 94.0–95.2) versus 95.6% (CI 95.3–95.8) in the reference group for revision for any reason. The risk for revision was higher in the Continuum group than in the reference group both for revision for any reason (HR 1.3 [CI 1.2–1.5)]) and for revision for dislocation (HR 1.9 [CI 1.5–2.3]). There was no difference in the rates of revision because of infection (HR 0.99 [CI 0.78–1.3]). Use of a neutral liner increased the risk for revision due to dislocation in comparison with the use of an elevated rim liner in the Continuum group (HR 1.7 [CI 1.2–2.5]).

Interpretation — THA with Continuum cups is associated with an increased risk of revision compared with other uncemented cups, mainly due to revisions because of dislocation. Our results support the use of an elevated liner when Continuum cups are used for primary THA.  相似文献   

7.
Background and purpose — Ceramic-on-ceramic (CoC) bearings were introduced in total hip arthroplasty (THA) to reduce problems related to polyethylene wear. We compared the 9-year revision risk for cementless CoC THA and for cementless metal-on-polyethylene (MoP) THA.

Patients and methods — In this prospective, population-based study from the Danish Hip Arthroplasty Registry, we identified all the primary cementless THAs that had been performed from 2002 through 2009 (n = 25,656). Of these, 1,773 THAs with CoC bearings and 9,323 THAs with MoP bearings were included in the study. To estimate the relative risk (RR) of revision, we used regression with the pseudo-value approach and treated death as a competing risk.

Results — 444 revisions were identified: 4.0% for CoC THA (71 of 1,773) and 4.0% for MoP THA (373 of 9,323). No statistically significant difference in the risk of revision for any reason was found for CoC and MoP bearings after 9 years of follow-up (adjusted RR = 1.3, 95% CI: 0.72–2.4). Revision rates due to component failure were 0.5% (n = 8) for CoC bearings and 0.1% (n = 6) for MoP bearings (p < 0.001). 6 patients with CoC bearings (0.34%) underwent revision due to ceramic fracture.

Interpretation — When compared to the “standard” MoP bearings, CoC THA had a 33% higher (though not statistically significantly higher) risk of revision for any reason at 9 years.  相似文献   

8.
Background and purpose — Trabecular metal (TM) cups have demonstrated favorable results in acetabular revision and their use in primary total hip arthroplasty (THA) is increasing. Some evidence show that TM cups might decrease periprosthetic infection (PPI) incidence. We compared the survivorship of TM cups with that of other uncemented cups in primary THA, and evaluated whether the use of TM cups is associated with a lower risk of PPI.

Patients and methods — 10,113 primary THAs with TM cup and 85,596 THAs with other uncemented cups from 2 high-quality national arthroplasty registries were included. The mean follow-up times were 3.0 years for the TM cups and 3.8 years for the other uncemented cups.

Results — The overall survivorship up to 8 years for TM cups and other uncemented cups was 94.4% and 96.2%, respectively (p = < 0.001). Adjusting for relevant covariates in a Cox regression model the TM cups had a persistently higher revision risk than other uncemented cups (HR =1.5, 95% CI 1.4–1.7, p = < 0.001). There was a slightly higher, though not statistically significant, revision rate for PPI in the TM group (1.2, 95% CI 1.0–1.6, p = 0.09).

Interpretation — Risk of revision for any reason was higher for the TM cup than for other uncemented cups in primary THA. In contrast to our hypothesis, there was no evidence that the revision rate for PPI was lower in the TM cup patients. Regardless of the promising early and mid-term results for TM cups in hip revision arthroplasty, we would like to sound a note of caution on the increasing use of the TM design, especially in uncomplicated primary THAs, where uncemented titanium cups are considered to provide a reliable outcome.  相似文献   


9.
Background and purpose — In Sweden, less than 5% of patients who undergo total hip arthroplasty (THA) have revision. Younger patients have an increased risk of revision. New prosthetic designs are being introduced in order to improve outcomes further. We investigated whether the introductory phase of new cup designs would increase the revision rate.

Patients and methods — All THAs and first-time cup revisions performed from 1993 through 2011 were identified in the Swedish Hip Arthroplasty Register. The 15 types of cups used in more than 500 operations and inserted in more than 50 cases in each hospital (n = 52,903) were selected. All cups were given an order number, based on the order in which the cup had been inserted at each hospital. The influence of order number on the risk of revision was analyzed in a regression model, which was adjusted for potentially confounding demographic and surgical data. Revision within 2 years for all reasons (n = 940) was used as primary endpoint. Changes in the risk of revision based on the order number were analyzed using a spline.

Results — The order number of the cup had no influence on the risk of early revision (p ≥ 0.7). Categorizing the order number using cutoff values obtained from the splines did not result in any statistically significant changes in risk of revision (p ≥ 0.2).

Interpretation — We did not find any increased risk of early revision during the implementation phase of new cup designs. This finding is unexpected, and partly conflicts with data from other registries. The structured and stepwise introduction of new prosthesis designs, facilitated by the annual feedback from the Swedish Hip Arthroplasty Register, may partly explain this discrepancy.  相似文献   

10.
Background and purpose — Revision total hip arthroplasty (THA) is associated with higher dislocation rates than primary THA. We compared the risk of dislocation within 6 months and all-cause re-revision during the whole study period using either the dual-mobility cup or the unipolar cup.

Methods — We used a prospective hospital registry-based cohort including all total and cup-only revision THAs performed between 2003 and 2013. The cups used were either dual-mobility or unipolar; the choice was made according to the preference of the surgeon. 316 revision THAs were included. The mean age of the cohort was 69 (25–98) years and 160 THAs (51%) were performed in women. The dual-mobility group (group 1) included 150 THAs (48%) and the mean length of follow-up was 31 (0–128) months. The unipolar group (group 2) included 166 THAs (53%) and the mean length of follow-up was 52 (0–136) months.

Results — The incidence of dislocation within 6 months was significantly lower with the dual-mobility cup than with the unipolar cup (2.7% vs. 7.8%). The unadjusted risk ratio (RR) was 0.34 (95% CI: 0.11–1.02) and the adjusted RR was 0.28 (95% CI: 0.09–0.87). The number of patients needed to treat with a dual-mobility cup in order to prevent 1 case of dislocation was 19. The unadjusted incidence rate ratio for all-cause re-revision in the dual-mobility group compared to the unipolar group was 0.6 (95% CI: 0.3–1.4).

Interpretation — Use of a dual-mobility rather than a unipolar cup in revision THA reduced the risk of dislocation within 6 months.  相似文献   


11.
Background and purpose — The prevalence of obesity is on the rise, becoming a worldwide epidemic. The main purpose of this register-based observational study was to investigate whether different BMI classes are associated with increased risk of reoperation within 2 years, risk of revision within 5 years, and the risk of dying within 90 days after primary total hip arthroplasty (THA). We hypothesized that increasing BMI would increase these risks.

Patients and methods — We analyzed a cohort of 83,146 patients who had undergone an elective THA for primary osteoarthritis between 2008 and 2015 from the Swedish Hip Arthroplasty Register (SHAR). BMI was classified according to the World Health Organization (WHO) into 6 classes: < 18.5 as underweight, 18.5–24.9 as normal weight, 25–29.9 as overweight, 30–34.9 as class I obesity, 35–39.9 as class II obesity, and ≥ 40 as class III obesity.

Results — Both unadjusted and adjusted parameter estimates showed increasing risk of reoperation at 2 years and revision at 5 years with each overweight and obesity class, mainly due to increased risk of infection. Uncemented and reversed hybrid fixations and surgical approaches other than the posterior were all associated with increased risk. Obesity class III (≥ 40), male sex, and increasing ASA class were associated with increased 90-day mortality.

Interpretation — Increasing BMI was associated with 2-year reoperation and 5-year revision risks after primary THA where obese patients have a higher risk than overweight or normal weight patients. As infection seems to be the main cause, customizing preoperative optimization and prophylactic measures for obese patients may help reduce risk.  相似文献   


12.
Background and purpose — The use of a cemented cup together with an uncemented stem in total hip arthroplasty (THA) has become popular in Norway and Sweden during the last decade. The results of this prosthetic concept, reverse hybrid THA, have been sparsely described. The Nordic Arthroplasty Register Association (NARA) has already published 2 papers describing results of reverse hybrid THAs in different age groups. Based on data collected over 2 additional years, we wanted to perform in depth analyses of not only the reverse hybrid concept but also of the different cup/stem combinations used.

Patients and methods — From the NARA, we extracted data on reverse hybrid THAs from January 1, 2000 until December 31, 2013. 38,415 such hips were studied and compared with cemented THAs. The Kaplan-Meier method and Cox regression analyses were used to estimate the prosthesis survival and the relative risk of revision. The main endpoint was revision for any reason. We also performed specific analyses regarding the different reasons for revision and analyses regarding the cup/stem combinations used in more than 500 cases.

Results — We found a higher rate of revision for reverse hybrids than for cemented THAs, with an adjusted relative risk of revision (RR) of 1.4 (95% CI: 1.3–1.5). At 10 years, the survival rate was 94% (CI: 94–95) for cemented THAs and 92% (95% CI: 92–93) for reverse hybrids. The results for the reverse hybrid THAs were inferior to those for cemented THAs in patients aged 55 years or more (RR =1.1, CI: 1.0–1.3; p < 0.05). We found a higher rate of early revision due to periprosthetic femoral fracture for reverse hybrids than for cemented THAs in patients aged 55 years or more (RR =3.1, CI: 2.2–4.5; p < 0.001).

Interpretation — Reverse hybrid THAs had a slightly higher rate of revision than cemented THAs in patients aged 55 or more. The difference in survival was mainly caused by a higher incidence of early revision due to periprosthetic femoral fracture in the reversed hybrid THAs.  相似文献   


13.

Background and purpose

The aim of the present study was to assess incidence of and risk factors for infection after hip arthroplasty in data from 3 national health registries. We investigated differences in risk patterns between surgical site infection (SSI) and revision due to infection after primary total hip arthroplasty (THA) and hemiarthroplasty (HA).

Materials and methods

This observational study was based on prospective data from 2005–2009 on primary THAs and HAs from the Norwegian Arthroplasty Register (NAR), the Norwegian Hip Fracture Register (NHFR), and the Norwegian Surveillance System for Healthcare–Associated Infections (NOIS). The Norwegian Patient Register (NPR) was used for evaluation of case reporting. Cox regression analyses were performed with revision due to infection as endpoint for data from the NAR and the NHFR, and with SSI as the endpoint for data from the NOIS.

Results

The 1–year incidence of SSI in the NOIS was 3.0% after THA (167/5,540) and 7.3% after HA (103/1,416). The 1–year incidence of revision due to infection was 0.7% for THAs in the NAR (182/24,512) and 1.5% for HAs in the NHFR (128/8,262). Risk factors for SSI after THA were advanced age, ASA class higher than 2, and short duration of surgery. For THA, the risk factors for revision due to infection were male sex, advanced age, ASA class higher than 1, emergency surgery, uncemented fixation, and a National Nosocomial Infection Surveillance (NNIS) risk index of 2 or more. For HAs inserted after fracture, age less than 60 and short duration of surgery were risk factors of revision due to infection.

Interpretation

The incidences of SSI and revision due to infection after primary hip replacements in Norway are similar to those in other countries. There may be differences in risk pattern between SSI and revision due to infection after arthroplasty. The risk patterns for revision due to infection appear to be different for HA and THA.Increasing incidence of revision due to infection after primary total hip arthroplasty (THA) has been observed in different countries during the last decade (Kurtz et al. 2008, Dale et al. 2009, Pedersen et al. 2010). There have been several studies on incidence of and risk factors for infection based on data from surveillance systems (Ridgeway et al. 2005, Mannien et al. 2008), arthroplasty (quality) registers (Berbari et al. 1998, Dale et al. 2009, Pedersen et al. 2010), and administrative databases (Mahomed et al. 2003, Kurtz et al. 2008, Ong et al. 2009). There have been reviews on incidence of and risk factors for infection after hip arthroplasty, based on publications from databases with different definitions of infection (Urquhart et al. 2009, Jämsen et al. 2010a). Superficial surgical site infections (SSIs) may have risk factors that are different from those of full surgical revisions due to infection. Furthermore, THA and hip hemiarthroplasty (HA) may have different patterns of risk of infection (Ridgeway et al. 2005, Cordero–Ampuero and de Dios 2010).In the present study, we used data from 3 national health registries in Norway to assess incidence and some risk factors for infection after primary hip arthroplasty. Differences in risk patterns between SSI and revision due to infection were investigated for HA and THA.  相似文献   

14.
Background and purpose — Combining components from different manufacturers in total hip arthroplasty (THA) is common practice worldwide. We determined the proportion of THAs used in the Netherlands that consist of components from different manufacturers, and compared the revision rates of these mixed THAs with those of non-mixed THAs.

Patients and methods — Data on primary and revision hip arthroplasty are recorded in the LROI, the nationwide population-based arthroplasty register in the Netherlands. We selected all 163,360 primary THAs that were performed in the period 2007–2014. Based on the manufacturers of the components, 4 groups were discerned: non-mixed THAs with components from the same manufacturer (n = 142,964); mixed stem-head THAs with different manufacturers for the femoral stem and head (n = 3,663); mixed head-cup THAs with different head and cup manufacturers (n = 12,960), and mixed stem-head-cup THAs with different femoral stem, head, and cup manufacturers (n = 1,773). Mixed prostheses were defined as THAs (stem, head, and cup) composed of components made by different manufacturers.

Results — 11% of THAs had mixed components (n = 18,396). The 6-year revision rates were similar for mixed and non-mixed THAs: 3.4% (95% CI: 3.1w–3.7) for mixed THAs and 3.5% (95% CI: 3.4–3.7) for non-mixed THAs. Revision of primary THAs due to loosening of the acetabulum was more common in mixed THAs (16% vs. 12%).

Interpretation — Over an 8-year period in the Netherlands, 11% of THAs had mixed components—with similar medium-term revision rates to those of non-mixed THAs.  相似文献   


15.

Purpose

Dislocation is a leading cause of failure after revision total hip arthroplasty (THA). This study was conducted to examine the risk factors for dislocation as well as their recurrence after revision THA.

Methods

We retrospectively reviewed 178 revision THAs in 162 patients between 1998 and 2013. The mean patient age was 65.2 years at operation and the mean follow-up period was 6.7 years. Multivariate logistic regression was performed to identify risk factors for dislocation, and further comparison was made between patients with single and recurrent dislocations.

Results

Sixteen hips in 15 patients (9.0 %) dislocated at a mean of 9.1 months (range, 0–83 months) after revision THA. Multivariate analysis identified advanced age (odds ratio [OR]?=?2.94/10 years) and osteonecrosis of the femoral head (OR?=?7.71) as the independent risk factors for any dislocations. Risk factors for recurrent dislocations, which were observed in eight hips (50 %), were later dislocations (≥4 months) and lower BMI.

Conclusion

Dislocation is a serious problem after revision THA with multiple risk factors. Although our findings were limited to revision THAs done through posterolateral approach, recognition of these factors is helpful in patient education and surgical planning.
  相似文献   

16.
《Acta orthopaedica》2013,84(3):207-213
Background and purpose Population-based registry data from the Nordic Arthroplasty Register Association (NARA) and from the National Joint Register of England and Wales have revealed that the outcome after hip resurfacing arthroplasty (HRA) is inferior to that of conventional total hip arthroplasty (THA). We analyzed the short-term survival of 4,401 HRAs in the Finnish Arthroplasty Register.

Methods We compared the revision risk of the 4,401 HRAs from the Register to that of 48,409 THAs performed during the same time period. The median follow-up time was 3.5 (0–9) years for HRAs and 3.9 (0–9) years for THAs.

Results There was no statistically significant difference in revision risk between HRAs and THAs (RR = 0.93, 95% CI: 0.78–1.10). Female patients had about double the revision risk of male patients (RR = 2.0, CI: 1.4–2.7). Hospitals that had performed 100 or more HRA procedures had a lower revision risk than those with less than 100 HRAs (RR = 0.6, CI: 0.4–0.9). Articular Surface Replacement (ASR, DePuy) had inferior outcome with higher revision risk than the Birmingham Hip Resurfacing implant (BHR, Smith & Nephew), the reference implant (RR = 1.8, CI: 1.2–2.7).

Interpretation We found that HRA had comparable short-term survivorship to THA at a nationwide level. Implant design had an influence on revision rates. ASR had higher revision risk. Low hospital procedure volume worsened the outcome of HRA. Female patients had twice the revision risk of male patients.  相似文献   

17.
Background and purpose — According to previous Nordic Arthroplasty Register Association (NARA) data, the 10-year implant survival of cemented total hip arthroplasties (THAs) is 94% in patients aged 65–74 and 96% in patients aged 75 or more. Here we report a brand-level comparison of cemented THA based on the NARA database, which has not been done previously.

Patients and methods — We determined the rate of implant survival of the 9 most common cemented THAs in the NARA database. We used Kaplan-Meier analysis with 95% CI to study implant survival at 10 and 15 years, and Cox multiple regression to assess survival and hazard ratios (HRs), with revision for any reason as endpoint and with adjustment for age, sex, diagnosis, and femoral head material.

Results — Spectron EF THA (89.9% (CI: 89.3–90.5)) and Elite THA (89.8% (CI: 89.0–90.6)) had the lowest 10-year survivorship. Lubinus (95.7% survival, CI: 95.5–95.9), MS 30 (96.6%, CI: 95.8–97.4), and C-stem THA (95.8%, CI: 94.8–96.8) had a 10-year survivorship of at least 95%. Lubinus (revision risk (RR)?=?0.77, CI: 0.73–0.81), Müller (RR =0.83, CI: 0.70–0.99), MS-30 (RR =0.73, CI: 0.63–0.86), C-stem (RR =0.70, CI: 0.55–0.90), and Exeter Duration THA (RR =0.84, CI: 0.77–0.90) had a lower risk of revision than Charnley THA, the reference implant.

Interpretation — The Spectron EF THA and the Elite THA had a lower implant survival than the Charnley, Exeter, and Lubinus THAs. Implant survival of the Müller, MS 30, CPT, and C-stem THAs was above the acceptable limit for 10-year survival.  相似文献   

18.

Background

Exchangeable neck stems, defined as those with a dual taper (that is, a modular junction between the femoral head and the femoral neck and an additional junction between the neck and the stem body), were introduced in THA to improve restoration of joint biomechanics (restoring anteversion, offset, and limb length) and reduce the risk of dislocation. However exchangeable necks have been reported to result in adverse effects such as stem fractures and acute local tissue reaction. Whether they result in a net improvement to or impairment of reconstructive survivorship remains controversial.

Questions/Purposes

(1) To compare the prosthetic survivorship and all-cause revision risk of exchangeable femoral neck THAs versus fixed neck THAs, taking known prosthetic revision risk factors into account; and (2) to compare the cause-specific revision risk of exchangeable femoral neck THAs versus fixed neck THAs, adjusting for known prosthetic risk factors.

Methods

Using French national health-insurance databases, we identified all French patients older than 40 years who underwent primary THA from 2009 through 2012. To ensure accuracy of the data, we considered only beneficiaries of the general insurance scheme (approximately 77% of the population). Characteristics of the prosthesis and the patients receiving an exchangeable femoral neck THA were compared with those receiving a fixed femoral neck THA (defined as femoral stem with only the head being exchangeable). Revision was the event of interest. Followup started on the date the THA was performed, until the patient experienced revision, died, was lost to followup, or until the followup period ended (December 31, 2014), whichever came first. Competing risk THA survivorship was calculated and compared (purpose 1), as were cause-specific Cox regression models (purpose 2). The study cohort included 324,108 individuals with a mean age of 77 years. A total of 24% underwent THA for acute trauma, and 3% of the group received an exchangeable neck THA. During the median 45-month followup (mean, 42 months; minimum, 1 day; maximum, 6 years), 11,968 individuals underwent prosthetic revision.

Results

The cumulative revision incidence was 6.5% (95% CI, 5.8%–7.3%) for exchangeable neck THAs versus 4.7% (95% CI, 4.6%–4.8%) for fixed neck THAs (p < 0.001). After controlling for potential confounding variables including age, sex, comorbidities, indication for THA, cementation, bearing surface, and the characteristics of the center where the implantation was performed, we found that the exchangeable femoral neck THA was associated with an increased hazard ratio (HR) of revision of 1.26 (95% CI, 1.14–1.38; p < 0.001) compared with the fixed neck THA. When dealing with cause-specific revision, exchangeable neck THAs had a higher incidence of revision for implant failure or periprosthetic fracture, and for mechanical complications; adjusted HRs were, respectively, 1.68 (95% CI, 1.24–2.27; p < 0.001) and 1.27 (95% CI, 1.13–1.43; p < 0.001), for exchangeable neck THAs compared with fixed ones.

Conclusions

Exchangeable neck THAs had poorer survivorship independent of other prosthetic revision risk factors. Accordingly, expected anatomic and functional benefits should be carefully assessed before choosing this design.

Level of Evidence

Level III, therapeutic study.
  相似文献   

19.
Background and purpose — Alternative bearing surfaces such as ceramics and highly crosslinked polyethylene (HXLPE) were developed in order to further improve implant performance of total hip arthroplasties (THAs). Whether these alternative bearing surfaces result in increased longevity is subject to debate.

Patients and methods — Using the Dutch Arthroplasty Register (LROI), we identified all patients with a primary, non-metal-on-metal THA implanted in the Netherlands in the period 2007–2016 (n = 209,912). Cumulative incidence of revision was calculated to determine differences in survivorship of THAs according to bearing type: metal-on-polyethylene (MoPE), metal-on-HXLPE (MoHXLPE), ceramic-on-polyethylene (CoPE), ceramic-on-HXLPE (CoHXLPE), ceramic-on-ceramic (CoC), and oxidized-zirconium-on-(HXL)polyethylene (Ox(HXL)PE). Multivariable Cox proportional hazard regression ratios (HRs) were used for comparisons.

Results — After adjustment for confounders, CoHXLPE, CoC, and Ox(HXL)PE resulted in a statistically significantly lower risk of revision compared with MoPE after 9 years follow-up (HR =0.8–0.9 respectively, compared with HR =1.0). For small (22–28?mm) femoral head THAs, lower revision rates were found for CoPE and CoHXLPE (HR =0.9). In the 36?mm femoral head subgroup, CoC-bearing THAs had a lower HR compared with MoHXLPE (HR =0.7 versus 1.0). Crude revision rates in young patients (< 60 years) for CoHXLPE, CoC, and Ox(HXL)PE (HR =0.7) were lower than MoPE (HR =1.0). However, after adjustment for case mix and confounders these differences were not statistically significant.

Interpretation — We found a mid-term lower risk of revision for CoHXLPE, CoC, and Ox(HXL)PE bearings compared with traditional MoPE-bearing surfaces.  相似文献   

20.
《The Journal of arthroplasty》2022,37(6):1136-1142
BackgroundVitamin E-doped cross-linked polyethylene (VEPE) liners were introduced in total hip arthroplasty (THA) to reduce wear and risk of aseptic loosening and liner fracture. We report this nationwide population-based study to investigate the safety of VEPE liners for THA compared to cross-linked annealed or remelted polyethylene (XLPE).MethodsWe included THAs from The Danish Hip Arthroplasty Register from January 1, 2008 to June 30, 2019, with uncemented cup, VEPE or XLPE liner, and metal or ceramic head. The outcome was revision due to (1) polyethylene-related endpoints (aseptic loosening, granuloma, osteolysis, or liner fractures) and (2) other endpoints.ResultsA total of 110,803 THAs were assessed for eligibility and 53,842 THAs (46,645 patients) were included in the study: 5069 (9.4%) THAs with a VEPE liner and 48,773 (91.6%) with a XLPE liner. Median observation time was 5.48 (interquartile range 3.80-7.15) years for VEPE and 4.85 (interquartile range 2.68-7.76) for XLPE. VEPE had a lower risk of revision for polyethylene-related endpoints compared to XLPE (hazard ratio [HR] 0.60, 95% confidence interval 0.36-0.98) during complete follow-up. THAs with VEPE liners were associated with increased risk of any revision within the first 3 months (HR 1.62, 1.36-1.94), revision recorded as aseptic loosening within 3 months (HR 4.46, 2.26-8.80), and periprosthetic fracture within 3 months (HR 2.57, 1.98, 3.33).ConclusionVEPE liners had a lower risk of revision due to polyethylene-related endpoints, but a higher risk of all-cause revision within 3 months.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号