首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 203 毫秒
1.
目的:评价国产小腰大边封堵器封堵多出口膜部瘤型室间隔缺损(VSD)的可行性、安全性和疗效。方法:选择69例多出口膜部瘤型VSD患者,经左心室造影证实右心室面均有多个出口。其中29例患者选用普通对称封堵器进行封堵(A组);40例患者选用小腰大边封堵器进行封堵(B组)。2组患者分别根据膜部瘤大小、形态、位置及膜部瘤组织粘连牢固程度,置入相应型号的普通对称封堵器或小腰大边封堵器,封堵后15min重复左心室造影和经胸超声心动图检查(TTE),观察封堵的即刻效果。术后连续心电监护5d。2组患者均于术后1、3、6个月定期心电图、TTE检查。结果:A组成功封堵19例,术中并发左、右束支传导阻滞各1例,1例术后造影示少量残余分流(<3mm),1个月后超声复查无残余分流,另10例因封堵器未能完全覆盖多发缺损口或封堵器引起心室流出道狭窄而换用小腰大边封堵器封堵成功;B组40例患者均一次封堵成功,3例术后造影示少量残余分流(<3mm),1个月后超声复查无残余分流,术中并发左、右束支传导阻滞分别为3例和2例。结论:经导管应用国产小腰大边封堵器封堵多出口膜部瘤型VSD疗效可靠,成功率高,并发症少,与普通对称封堵器相比有明显的优势。  相似文献   

2.
室间隔缺损介入治疗后并发封堵器移位的原因分析   总被引:7,自引:0,他引:7       下载免费PDF全文
目的探讨经导管介入治疗室间隔缺损(VSD)发生封堵器移位的原因和预防措施。方法介入治疗后封堵器移位患者4(男3,女1)例,3例为膜周部VSD伴膜部瘤,1例为嵴内型VSD,缺损直径分别为13、12、12和10mm,所选用的封堵器分别为16、12mm国产对称型膜部VSD封堵器,14mmAmplatzer膜部VSD封堵器和14mm国产偏心型膜部VSD封堵器。结果4例均一次性封堵成功。术后即刻均无残余分流。2例在术后4和12h分别发生溶血,超声心动图检查封堵器位置无明显变化,但均有明显残余分流。经药物治疗后,溶血恢复正常,残余分流消失。1例术后第4天,心电图检查为Ⅲ度房室传导阻滞,超声心动图发现封堵器明显向囊袋出口移位。转心脏外科手术取出封堵器并修补缺损,术后患者Ⅲ度AVB恢复。1例嵴内型VSD术后2周,超声心动图发现封堵器向右心室移位,有明显残余分流。随访4个月残余分流减少。结论VSD封堵治疗后,封堵器移位与缺损的病理解剖特性有关。多发生在伴有膜部瘤的膜部VSD和嵴内型VSD。  相似文献   

3.
应用新型Amplatzer封堵器治疗膜周部室间隔缺损的初步研究   总被引:53,自引:1,他引:53  
目的 探讨新型Amplatzer室间隔缺损封堵器治疗膜周部室间隔缺损 (VSD)的可行性及近期疗效。方法  2 0 0 2年 11月至 2 0 0 3年 7月采用新型Amplatzer膜部VSD封堵器对 2 6例 (男 11例 ,女 15例 )膜周部VSD(2 0例合并膜部瘤 )患者进行封堵治疗。患者年龄 3~ 4 0 (16 4± 10 7)岁 ,胸超声提示VSD的直径为 3~ 14 (4 7± 1 0 )mm。在透视及超声监测下通过建立股动静脉轨道、经右心系统释放封堵器 ,并分别于术后 2周、1个月、3个月、6个月进行随访。结果  2 5例患者封堵器置入成功 ,技术成功率 96 %。术后即刻超声及造影均示完全封堵 2 0例 ,少量残余分流 2例 ,微量残余分流 3例 ,均在 1天至 3个月内消失 ,总完全封堵率为 10 0 %。术后出现完全性左束支传导阻滞 1例 ,但无心肌受损表现 ,余无其他严重并发症发生。 1例嵴内型VSD由于距主动脉瓣较近 ,封堵未成功。结论 应用新型Amplatzer膜部VSD封堵器治疗膜周部VSD是安全有效的 ,近期效果良好 ,但中、远期疗效尚需更大规模的临床观察  相似文献   

4.
介入治疗室间隔缺损修补术后残余漏的初步研究   总被引:3,自引:0,他引:3  
目的:探讨室间隔缺损(VSD)外科修补术后残余漏介入治疗的方法学及临床疗效。方法:对年龄在7~58岁之间的12例VSD修补术后残余漏患者行介入治疗。封堵材料为Amplatzer非对称性室间隔缺损封堵器(AAVSDO)和对称性国产室间隔缺损封堵器(VSDO)。距手术修补时间平均为(10.2±5.5)年;9例为膜部室间隔缺损修补术后患者,3例为法乐四联征(TOF)术后患者;8例修补术后心电图示完全性右束支传导阻滞(CRBBB),1例修补术后出现Ⅲ度房室传导阻滞并安装了永久起搏器。以经食道超声(TEE)或经胸超声(TTE)以及左心室造影测量残余漏大小。9例患者各有1个残余漏口,3例患者右心室面有两个残余漏口。结果:超声及左心室造影所测残余漏直径分别为3~10 mm和4~10 mm,所选用封堵器直径为4~12 mm,封堵15分钟后造影示11例残余漏完全封堵,1例残留少量分流,术后1个月复查时残余分流消失。所有患者未出现新的心律失常及其它并发症。结论:介入治疗室间隔缺损修补术后残余漏安全有效,其远期效果需长期随访观察。  相似文献   

5.
目的:探讨应用双封堵器对复杂膜部瘤型室间隔缺损(VSD)进行介入封堵治疗的可行性、有效性和安全性。方法: 12例复杂膜部瘤型VSD患者,左心室造影后常规右股动脉-左心室-VSD-右心室-右股静脉输送轨道,对VSD进行封堵,重复左心室造影,发现存在不能接受的残余分流,遂建立右股动脉-左心室-VSD-右心室-左股静脉输送轨道,应用第2枚封堵器对残余分流进行封堵,左心室、升主动脉造影以及超声心动图检查确认封堵效果良好,释放封堵器。术后1、3、6、12个月复查超声心动图、X线检查和12导联心电图。结果: 12例患者均封堵成功。术毕即刻造影和超声心动图检查示封堵效果良好,无残余分流,各组瓣膜功能良好,无并发症发生。随访期间所有患者杂音消失,超声心动图检查无残余分流,心电图检查均为窦性心律,无房室传导阻滞或束支传导阻滞。结论: 应用双封堵器对复杂膜部瘤型VSD进行封堵治疗是可行的,且具有满意的疗效和安全性。  相似文献   

6.
目的:结合介入治疗实际对室间隔缺损(VSD)伴膜部瘤形成进行造影分型,并对不同类型膜部瘤的介入封堵方法进行探讨。方法:2002-11~2003-11采用新型Amplatzer膜部室间隔缺损封堵器对32例并发膜部瘤的膜周部VSD行封堵治疗,平均年龄19(3~48)岁。封堵术前常规行左室造影,在经胸超声心动图(TTE)及透视监测下通过建立股动静脉轨道、经右心系统释放封堵器,并于术后1、3、6、12个月随访复查胸片、超声心动图、心电图。  相似文献   

7.
目的:研究应用国产封堵器治疗先天性心脏病的近期临床疗效。方法:3~30岁的先天性心脏病患者51例,继发孔型房间隔缺损(ASD)10例,室间隔缺损(VSD)27例,动脉导管未闭(PDA)13例,ASD+VSD1例。在TTE及X线检查下,经皮沿导丝经传送鞘管送合适的国产封堵器至缺损处行封堵。结果:①TTE测量ASD缺损为6~26(15±7)mm,所用封堵器为8~32(19±8)mm。术后即刻TTE未发现残余分流。1例于术后5h封堵器脱落。②左室造影测量VSD直径为2.3~14(6±3)mm,封堵器4~18(8±3)mm,无残余分流,术后即刻完全封堵率100%。③造影测量PDA最窄处直径为2.8~14(…  相似文献   

8.
李红梅  叶季鲜  高群  代政学  张丙芳 《心脏杂志》2005,17(6):597-598,602
目的:分析国产对称双盘状封堵器经导管治疗室间隔缺损(VSD)的疗效。方法:21例,全部为膜部室间隔缺损,年龄3.035.0(7.6±8.4)岁。VSD左室面直径为2.212.0(6.2±4.2)mm。经6F-10F传送鞘置入国产对称双盘状封堵器,封堵后即刻行左心室造影,术后1 d、1、6及12月行超声心动图检查观察有无残余分流。结果:封堵器植入成功20例,植入技术成功率95%。术后即刻左心室造影示4例(20%)存在微少量残余分流,16例(80%)封堵完全无残余分流。术后2448 h超声心动图示分流完全消失19(95%)、微少量残余分流1例(5%)。1例封堵术后3 d发生一过性Ⅲ度房室传导阻滞,经过410 d内科保守治疗治愈。1月超声心动图所有病例未见残余分流。结论:应用国产双盘状封堵器治疗VSD是一种安全有效的介入方法,操作简便,成功率高,近期疗效可靠。  相似文献   

9.
目的探讨国产单封堵器对多孔膜部瘤室缺的封堵效果,并进行术后随访,评价其安全性。方法52例多孔膜部瘤室缺患者,经超声心动图(TTE)确诊,治疗均选用国产对称封堵器进行封堵。首先左室左前斜45°-60°,头位20°造影,根据造影室缺大小、形态选择大小合适的封堵器,建立股动静脉轨道。封堵后即刻左室造影,观察有无残余分流。封堵后随访24h,1、3、6个月,1年。随访指标包括心电图、TTE、放射线胸片。结果52例患者51例封堵成功,1例封堵成功后发生腱索断裂。1例因2次封堵器置入导致室缺明显增大,2例转入外科手术(包括腱索断裂1例),1例封堵器置入膜部瘤内。术后即刻造影,26例有少至微量残余分流,其中20例术后24h分流消失,其余4例于1、3.6个月和1年随访中发现分流消失,2例有少量分流;TTE显示封堵器位置良好。所有患者对主动脉瓣、房室瓣无影响,无栓塞、感染性心内膜炎、溶血等发生。术后8例心电图发生不完全性右束支阻滞,随访中5例持续不完全性右束支阻滞,2例完全性右束支传导阻滞,1例持续完全性右束支传导阻滞。术后3-5d内出现交界性逸搏心律3例,经使用肾上腺皮质激素治疗后恢复窦性心律。1例患者在术后第9天发生完全性房室传导阻滞,置入临时起搏器,经肾上腺皮质激素及维生素C治疗,术后第12天恢复窦性心律,仍为左前分支传导阻滞伴完全性右束支传导阻滞。结论不论多孔膜部瘤室间隔缺损距主动脉瓣有无距离均可选择封堵治疗,Qp/Qs〉1.5,最大孔〈10mm患者均为封堵治疗的适应证。经过2个月至3年的随访,疗效确切、安全。  相似文献   

10.
室间隔缺损封堵治疗的疗效和安全性   总被引:66,自引:3,他引:66  
目的 应用国产和进口室间隔缺损 (室缺 )封堵器封堵室缺 ,通过 3~ 6个月的随访来评价其疗效和安全性。方法  30例室缺患者 ,男性 12例 ,女性 18例 ,年龄 6~ 4 2岁 ,体重 2 6~ 77(45 3±2 1 4 )kg ,身高 1 31~ 1 76m。 2 8例为室间隔膜部缺损 ,其中 14例患者伴有室间隔膜部瘤 ;另 2例为嵴下型室缺。本组最初 3例使用经食管超声心动图 (TEE)监测 ,以后 2 7例使用经体表超声心动图 (TTE)监测。封堵器选用国产封堵器 2 5例、Amplatzer 3例。室缺封堵术后 72h进行TTE复查 ,术后 1个月、3个月、6个月随访心电图、TTE、X线 ,观察疗效和安全性。结果  2 8例封堵手术成功 ,即刻手术成功率93 3% ,无残余分流 ,对主动脉瓣无影响 ,对房室瓣无影响 ,无血管内溶血。 14例伴有室间隔膜部瘤的患者成功封堵。术后次日有 1例出现非阵发性交界性心动过速伴干扰性房室分离 ,经使用肾上腺皮质激素治疗后缓解。 2 8例术后 72h复查TTE ,均无残余分流 ,主动脉瓣、房室瓣均无影响 ,经过 1个月、3个月、6个月的随访 ,原有临床不适症状缓解 ,未发现有发热、栓塞、感染性心内膜炎等临床表现 ,TTE显示封堵器位置稳定 ,室间隔水平无分流 ,主动脉瓣、房室瓣无影响。结论 室缺边缘距离半月瓣大于 3mm以上、直径 10mm以下、伴或  相似文献   

11.
Several devices are available for percutaneous patent foramen ovale (PFO) closure. Over the past 3 years our planned treatment strategy of PFO closure has been routine use of the GORE-HELEX septal occluder device, followed by 6 months of aspirin therapy. We present the safety and feasibility of routinely using this device for all patients undergoing percutaneous PFO closure, with 3-month transthoracic echocardiogram (TTE) follow up. In total, 75 adult patients (44.0+/-11.7 years; 45.3% male) were referred for PFO closure during the study period. All patients underwent echocardiography prior to PFO closure. In 5 patients no PFO was found, and 1 patient had an atrial secundum defect closed using the Amplatzer septal occluder. Of the 69 remaining patients with PFO, 68/69 (98.6%) underwent closure with the GORE-HELEX device. Six of 69 cases required device retrieval and 5 of 6 were replaced successfully with a second GORE-HELEX device. One of the 6, a large PFO associated with atrial septal aneurysm, was replaced using the Amplatzer septal occluder. There were no major complications. At 3-month follow up, 65/68 (95.6%) had no residual shunt on TTE, and 3 patients had small residual shunts thought to be related to incomplete endothelialisation at 3 months. In conclusion, percutaneous PFO closure using the GORE-HELEX septal occluder device is safe and feasible, with no major peri-procedural complications and excellent short-term results at 3-month follow up.  相似文献   

12.
Transcatheter closure of congenital muscular ventricular septal defect   总被引:18,自引:0,他引:18  
The success with occlusion devices for the closure of atrial septal defects and patent ductus arteriosus prompted the transcatheter closure of single and multiple muscular ventricular septal defects (VSD). The procedure for VSD was first attempted by Lock et al. in 1988 and devices originally designed for the closure of other intracardiac defects (Rashkind umbrella device, Lock clamshell, Cardioseal, coils, Sideris buttoned device etc.) were used with a variable success rate and a residual shunt. Recently, specially designed Amplatzer muscular VSD occluder and Sideris device are in use. The Amplatzer muscular VSD occluder has been undergoing clinical trial since 1998 after the animal experiments had shown 100% occlusion and complete endothelization at 3 months. The procedure was first attempted in August 1995 using the Rashkind umbrella device and since April 1998 only the Amplatzer muscular VSD occluder has been used. Of the149 patients who underwent transcatheter closure of VSD, 50 had muscular trabecular defects in various locations: mid-muscular, anterior, posterior, or apical. All cases were selected by detailed transthoracic and/or transesophageal echocardiography (TTE) and aneurysm of the muscular septum was observed in three of them. The age range was 3-28 years and the diameter of VSD was 4-11 mm. In all but one patient, the device was deployed from the venous side. Simultaneous TTE was done for proper positioning of the device and continuous electrocardiographic monitoring was also done for any arrhythmia/conduction defects. All patients were followed up every 3 months and received 3-5 mg/kg aspirin for 6 months. The procedure was successful in all patients. The Rashkind umbrella device (17 mm) was used in two and Amplatzer muscular VSD occluder (6-14 mm) in 48 patients. Forty-four devices were delivered by antegrade transvenous approach and six by the transjugular route. None had residual shunt, new aortic regurgitation, or tricuspid regurgitation. Transient complete heart block after 24 hours was noticed in one patient. On a follow-up of 2-90 months, the device was in position in all patients. There was no embolization of the device, and no late-conduction defects, infective endocarditis, or hemolysis. Transcatheter closure of muscular VSD is safe and efficacious, and should be considered as a procedure of choice as an alternative to surgery that avoids cardiopulmonary bypass.  相似文献   

13.
目的 总结经皮导管室间隔缺损介入封堵术的临床经验,并对326例患者的中期随访结果进行回顾性分析.方法 326例室间隔缺损患者均经临床和经胸超声心动图(TTE)确诊,排除干下型室间隔缺损,采取经皮导管室间隔缺损介入封堵术,术后即刻左心室造影和经胸超声心动图检查观察疗效,术后1d、1个月、3个月、6个月、1年、2年、3年、4年、5年行经胸超声心动图、X线胸片和超声心动图检查随访观察.结果 经皮导管室间隔缺损介入封堵成功率为98.3%(320/326),失败原因为室间隔缺损过大或过小、位置特殊、合并主动脉瓣脱垂及反流、损伤三尖瓣或主动脉瓣、房室传导阻滞等.术后并发症:1例术后1d封堵器移位,急诊心脏外科手术处理;2例8 kg患儿术后股动脉血栓形成,尿激酶溶栓后治愈;12例新出现三尖瓣轻度反流或原有三尖瓣反流增多;1例损伤主动脉瓣致中度反流,急诊外科手术处理;56例出现非阵发性交界性心动过速,经激素、人体白蛋白、营养心肌等治疗后恢复窦性心律;17例不完全性束支传导阻滞;5例完全性左束支传导阻滞.1例术后10个月出现二度Ⅱ型房室传导阻滞,治疗后恢复至二度Ⅰ型房室传导阻滞.1例术后8d出现脑出血,开颅发现脑血管畸形,外科处理后治愈.术后患者左心室舒张末内径、心胸比例较术前改善.结论 经皮导管室间隔缺损介入封堵术具有创伤小、并发症少、无需体外循环、成功率高等特点,值得推广,但应规范选择患者和长期随访.  相似文献   

14.
目的评价经胸超声心动图(VrE)在继发孔房间隔缺损(ASD)围手术期中的应用价值。方法术前筛选86例有外科手术适应证的继发孔ASD患者,TTE测量各切面ASD大小及残边情况,指导选择封堵器(ASO)型号,术中监测ASO置放及释放过程,术后随访观察。结果86例患者术前TTE测得ASD最大直径5~34(24.4±5.63)mm,所用ASO直径为8—40(27.5±7.12)mm。TTE成功引导81例ASO置人,总成功率为94.2%,其中双孔ASD2例,均置入单个ASO成功。5例术后即刻有微量或少量残余分流,术后3个月复查TTE分流完全消失。结论经导管ASD封堵术是安全可行的方法,T珏对ASD封堵术前病例选择、残边评估、ASO型号选择、术中监测ASO的置放全过程和术后疗效评价有重要临床价值。  相似文献   

15.
目的:观察用国产Amplatzer封堵器治疗继发孔型房间隔缺损(ASD)前后心脏结构及血浆心钠肽(ANP)、脑钠肽(BNP)的变化.探讨经导管ASD封堵术的影响。方法:应用超声心动图测量36例ASD患者封堵治疗前、治疗后1d、1月、3月、6月心脏结构参数,并分别测定相应时段血浆心钠肽、脑钠肽的浓度,另选取年龄及性别与之相匹配的健康人36例作为对照组。结果:同术前相比,术后1d、1月、3月、6月,右房、右室内径明显缩小(P〈0.05),而左室舒张末期内径在术后1月、3月明显增大(P〈0.05)。左室收缩末期内径、左房内径及左室射血分数在术前及术后没有明显变化。ASD组ANP、BNP水平在封堵前较对照组明显升高,在封堵1d后开始显著逐渐下降,到6月后基本恢复至正常水平(P均〈0.05)。结论:经导管ASD封堵术减轻了右心的容量负荷.使右房、右室内径明显缩小,也可在短期内改善左室的几何构型,血浆ANP、BNP水平可以作为评价经导管ASD封堵术对心脏容量负荷影响的一项有效指标。  相似文献   

16.
目的 评价经胸超声心动图监测 (TTE)Amplatzer封堵器介入治疗巨大房间隔缺损(ASD)的安全性和可行性。方法  2 1例住院患者 ,男 12例 ,女 9例 ;年龄 17~ 4 5岁 ;均经临床及超声心动图证实的继发孔型ASD ,以充盈球囊最大伸展直径加 2~ 4mm为原则选择封堵器型号 ,TTE监测下放置Amplatzer封堵器。随访有无残余分流及是否影响周围瓣膜和静脉功能 ,记录临床事件 (血栓栓塞、心功能不全、心律失常等 )。结果  2 1例全部封堵成功 ,TTE监测放置Amplatzer封堵成功 ,手术成功率 10 0 % ;术后即刻及 1天、3天、3个月、6个月、1年复查TTE观察无明显残余分流及影响周围瓣膜功能 ,也无腔、肺静脉狭窄 ,无血栓栓塞事件发生 ,无封堵器移位和脱落 ,心功能有不同程度的好转。1例发生频发房性心律失常 ,经心律平 4 5 0mg d治疗 1个月后消失 ,无其他并发症发生。结论 Amp latzer封堵器介入治疗成人巨大ASD是一种安全、有效的治疗方法 ,TTE监测ASD介入封堵治疗整个过程 ,可以提高一次释放成功率  相似文献   

17.
目的探讨应用导管介入治疗直径≥5mm婴幼儿大型动脉导管未闭(patent ductus arteriosus.PDA)的临床疗效。方法回顾性分析60例大型PDA(直径≥5mm)患儿的临床资料,着重分析手术方法、临床疗效和随访结果。结果56例PDA采用Amplatzer或国产先健动脉导管封堵器.3例采用膜部室间隔缺损封堵器,1例采用肌部室间隔缺损封堵器。封堵成功率为98.3%(59/60),术后1d超声心动图显示15%(9/60)微量至少量残余分流,术后3月超声心动图复查未见残余分流:3例采用室间隔缺损封堵器患儿术后12月超声心动图示左肺动脉血流速度增快。结论应用导管介入治疗直径≥5mm婴幼儿大型PDA是安全、有效的方法。  相似文献   

18.
目的分析经导管国产封堵器治疗小儿动脉导管未闭(patent duetus arteriosus,PDA)远期随访资料,评价其远期疗效、安全性及影响疗效的因素。方法PDA患儿接受国产封堵器治疗302例,病例均随访至2006年12月,进行回顾性队列研究。结果PDA最窄处直径在2.0~16(4.1±1.3)mm,其中直径超过12mm10例(3.3%)。成功植入4/6~22/24mm大小的封堵器298例(98.6%)。完成了随访244例,随访率为81%,随访时间24~82个月。需要再次接受治疗4例(1.3%),其中接受介入治疗3例(0.9%),包括因残余分流而溶血2例;因封堵器移位接受外科治疗1例(0.3%)。1年和5年无事件发生率为98.0%。残余分流率在1d,1个月,6个月,12个月,24个月和36个月分别为10.4%,3.7%,2.1%,0.8%,0.5%和0。10例巨大PDA应用大型封堵器封堵成功。结论应用国产封堵器治疗小儿PDA远期疗效确切.安全性好。  相似文献   

19.
目的比较偏心型封堵器与对称型封堵器介入治疗小儿膜周部室间隔缺损(perimembranous ventricular septal defects,PMVSD)的疗效及并发症。方法回顾分析2002年10月至2007年12月接受介入治疗的PMVSD患儿的临床资料,根据所用器械的不同分为偏心型封堵器组(偏心组)和对称型封堵器组(对称组),对术前基线资料和术后随访1年内的疗效及并发症进行对比。结果共有509例PMVSD患者入选,其中偏心组266例,对称组243例。两组基线资料中除室间隔缺损(VSD)与主动脉右冠瓣的距离偏心组小于对称组外(3.5±0.7mm比5.2±1.2mm,P=0.01),其余差异均无统计学意义(P〉0.05)。两组治疗成功率分别为95.5%和96.7%(P=0.98),术后即刻VSD完全闭合率对称组明显高于偏心组(96.7%比86.8%,P=0.001),但术后24h及1、3、6、12个月不同随访时间点的完全闭合率两组差异均无统计学意义(均为P〉0.05)。偏心组严重并发症发生率与对称组接近(3.8%比1.6%,P=0.060),但轻微并发症发生率两组存在差别(56.8%比42.8%,P〈0.001),其中主要是心律失常的发生率偏心组高于对称组(22.6%比13.6%,P〈0.001),而主动脉瓣反流(aortic regurgitation,AR)及三尖瓣反流(tricuspid regurgitation,TR)发生率差异无统计学意义(P〉0.05)。两组均无死亡病例一结论偏心型封堵器和对称型封堵器短、中期疔效相当,严重并发症发生率接近,但轻微并发症中心律失常的发生率偏心封堵器高于对称封堵器,  相似文献   

20.
应用Amplatzer偏心性封堵器介入治疗膜部室间隔缺损   总被引:27,自引:3,他引:27  
目的 应用Amplatzer偏心性封堵器治疗膜部室间隔缺损 (perimembraneventicularseptaldefect,PMVSD)并对近期疗效进行观察。方法  6例PMVSD患者均经胸超声心动图确诊 ,术中经左心室造影明确缺损直径为 3~ 9mm ,平均 5 5mm ;经左心系统、室间隔缺损处、右心系统建立导丝轨迹 ,沿导丝经传送鞘管送直径 6~ 12mm(平均 8mm)的Amplatzer封堵器至缺损处行封堵 ;术后 2 4h、1月、3月分别行经胸超声及X线检查观察临床疗效。结果 全组技术成功率 10 0 % ,术中未发生任何重要并发症。全部患者封堵后无一例存在残余分流 ,术后即刻完全封堵率 10 0 % ;术后 2 4h、1月及 3月经胸超声心动图检查无残余分流 ,X线检查全部显示肺血减少 ,心胸比例不同程度缩小。 1例患者术后出现完全性左束支传导阻滞 ,1月随访时消失。结论 经导管置入Amplatzer偏心性膜部室间隔缺损封堵器治疗PMVSD是一种成功率高、近期疗效可靠的介入方法 ,其远期疗效需进一步观察。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号