首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 46 毫秒
1.
两种消毒液调拌藻酸盐印模材对印模尺寸稳定性的影响   总被引:1,自引:1,他引:0  
目的:评价用两种消毒液直接调拌藻酸盐印模材对印模尺寸稳定性有无影响。方法:分别用蒸馏水、0.2%的次氯酸钠和0.1%的洗必泰调拌藻酸盐印模材,对同一试件制取20组印模,以蒸馏水调拌者为对照组。用超硬石膏灌模,40rain脱模静置24h测量模型三维标志点的长度再进行统计学分析。结果:试验组和对照组模型三维标志点长度无显著性差异。结论:0.2%的次氯酸钠或0.1%的洗必泰直接调拌藻酸盐印模材进行印模消毒不影响印模尺寸稳定性,可用于口腔科印模消毒。  相似文献   

2.
目的:对不同局部托盘及处理方式制取印模后的石膏模型尺寸精确性作一研究.方法:使用局部托盘制取一上颌标准模型的藻酸盐印模,灌注硬石膏模型.分别测量龈缘24近中边缘至27远中边缘(4个牙位),24远中边缘至27近中边缘(2个牙位)的长度,再与标准模型相应位置的长度进行对比分析.实验根据选用局部托盘的材料不同,分为铝制局部托盘组和钢制局部托盘组;根据托盘边缘是否粘结医用胶布,分为铝制局部托盘胶布粘边组和钢制局部托盘胶布粘边组;根据模型硬固后的测量时间不同,分为1h组和12h组.每组重复6次,数据记录为均数±标准差,采用SPSS 17.0统计分析软件行t检验(α=0.05).结果:当测量位置为24远中边缘-27近中边缘(2个牙位长度)时,标准模型-钢制托盘胶布粘边取灌模型间未见显著性差异(P=0.149),其余取灌模型组与标准模型组间均可见显著性差异;当测量位置为24近中边缘-27远中边缘(4个牙位长度)时,所有的取灌模型组与标准模型组间可见显著性差异.此外,不同长度的印模制取,任一铝制托盘(胶布粘边)取灌模型组和任一钢制托盘(胶布粘边)取灌模型组之间未见显著性差异.分别测量硬固1h和12h的石膏模型并进行对比,未见显著性差异.结论:2牙位长度的藻酸盐印模制取,钢制托盘胶布粘边制取印模后灌注的硬石膏模型与实物的尺寸更相符;4牙位长度的藻酸盐印模制取,钢制托盘制取的印模和铝制托盘印模在精确性方面没有区别;无论制取2个或4个牙位长度的藻酸盐印模,托盘材料和是否粘边取灌注的硬石膏模型尺寸比较没有显著性差异.  相似文献   

3.
《口腔医学》2013,(3):165-167
目的对藻酸盐印模不同灌注时间点的尺寸变化进行研究。方法将藻酸盐印模材料糊剂置于直径为9.5 cm的红色打样膏顶盖中振荡均匀后,把底部密封的回收必兰注射液空瓶垂直插入糊剂中制取印模并置于相对恒定环境留存10、40、80 min后,每一时段的印模都用普通石膏、硬石膏、超硬石膏灌注。1 h后脱模,用电子数显卡尺(测量精度0.005 mm)测量各组石膏模型的尺寸变化,数据x珋±s进行方差分析(α=0.05)。结果印模留存10 min普通石膏灌注组、硬石膏灌注组、超硬石膏灌注组的石膏模型表现收缩为主趋势,而在印模留存40 min和80 min普通石膏灌注组、硬石膏灌注组、超硬石膏灌注组的石膏模型表现膨胀为主趋势。此外,随印模留存时间延长,3种石膏灌注组模型尺寸变化量平均值逐渐增大,各组间可见显著性差异(P<0.05)。结论藻酸盐印模不同时间点其尺寸变化因材料的渗润和凝溢随时间延长表现为先膨胀后收缩且均值有增加的趋势。  相似文献   

4.
目的:本实验旨在比较使用藻酸盐印模材料制取不同形状物体阴模过程中的尺寸精确性.方法:分别使用藻酸盐印模材料制取正方体,圆柱体、三角体阴模,并用电子数显卡尺测量灌注的普通石膏、硬石膏、超硬石膏模型试件的尺寸,并与实物尺寸进行比较分析.数据进行ANOVA(α=0.05).结果:圆柱体印模尺寸变化较大,正方体印模尺寸变化较小,而三角体印模尺寸变化居中(P<0.05).正方体的普通石膏灌注阴模组,硬石膏灌注阴模组和超硬石膏灌注阴模组的尺寸变化百分率分别是0.044%,0.128%,0.370%.圆柱体的普通石膏灌注阴模组,硬石膏灌注阴模组和超硬石膏灌注阴模组的尺寸变化百分率分别是0.745%,0.665%,0.369%.三角体的普通石膏灌注阴模组,硬石膏灌注阴模组和超硬石膏灌注阴模组的尺寸变化百分率分别是0.557%,0.595%,0.561%.结论:三种形状中正方体对藻酸盐印模制取的尺寸变化影响较小,三角形次之,圆柱体变化较大.  相似文献   

5.
目的使用不同消毒剂浸泡消毒口腔印模,观察其对模型尺寸稳定性的影响。方法制取塑料母模印模试件60件,按消毒剂不同随机分为3组,每组18个试件,分别浸没于2%强化中性戊二醛,0.5%次氯酸,0.1%碘伏中。每组再按消毒时间不同分3组,每组6个试件,分别浸泡10min、20min、30min后取出灌注模型。对照组6个试件直接灌注模型。24h后测量显微镜测量各组石膏模型6近远中径(MD),6颊舌径(LB),6|6间距(CA),36间距(AP)线性长度值。SPSS10.0做统计学处理,统计藻酸钾印模浸泡前后模型尺寸有无显著改变及改变量。结果①使用析因设计两因素方差分析对模型测量值MD,LB,AP,CA进行分析。结果显示处理组P值均小于0.05,区组因素P值均大于0.05。②使用Dunnett-T检验把浸泡各时间组模型尺寸与浸泡前比较,结果显示浸泡10min模型线性长度与对照组均无显著性差别,浸泡20min,30min组各测量值与对照组相比均有显著性差异。结论①浸泡消毒藻酸钾印模,消毒剂种类不影响模型尺寸稳定性。消毒时间可影响模型尺寸稳定性。②随浸泡消毒时间延长,模型尺寸改变增大,浸泡30min内尺寸改变在临床允许范围内。  相似文献   

6.
消毒液浸泡消毒对藻酸盐印模尺寸稳定性影响的评价研究   总被引:1,自引:0,他引:1  
目的评价用三种消毒液浸泡不同时间后,四种藻酸盐印模的尺寸稳定性。方法采用符合YY1027国家行业标准和ISO 1563国际标准的标准试验装置,制取四种藻酸盐印模材料的标准印模,每种材料制取6组,每组5个印模,共120个印模。分别用2%戊二醛和84消毒液浸泡30分钟和40分钟、邻苯二甲醛消毒液(Ortho-phthalaldehyde,OPA)浸泡20分钟和30分钟。使用工具显微镜测量浸泡消毒处理前后各组印模的标志线长度,比较浸泡前后印模线性尺寸变化率,并对所得结果应用SPSS10.0软件进行统计学分析。结果①使用2%戊二醛、84消毒液浸泡处理前后,全部印模均发生显著膨胀形变(P<0.05),且形变随浸泡时间的延长而增大。②使用邻苯二甲醛消毒液浸泡处理前后,全部印模均发生显著收缩形变(P<0.05),且形变随浸泡时间的延长而增大。③不同材料的印模之间尺寸变化率的差异有显著性(P<0.05)。登士柏翡翠Jeltrate的形变率最小。④不同消毒液不同浸泡时间处理对印模尺寸稳定性影响的差异有显著性(P<0.05)。在相同浸泡时间时,使用2%戊二醛浸泡处理的印模形变率比使用84消毒液浸泡处理的印模形变率要小。结论①消毒...  相似文献   

7.
调合消毒法对藻酸盐印模精度的影响   总被引:15,自引:0,他引:15  
目的:研究藻酸盐印模材料与消毒液直接调合对印模精度的影响。方法:用0.25%NaClO、0.525%NaClO、0.5%84、1%84消毒液调合藻酸钾印模材作实验样本,以蒸馏水调合相同材料制取印模做对照,分别制取试件印模,用超硬石膏灌模,60min后脱模,石膏模型静置2h后测微显微镜下测量石膏模型,进行统计学分析。结果:实验组模型与对照组模型精度没有显著性变化,4组实验组模型间比较,其精度亦无显著性差异。结论:0.25%NaClO、0.525%NaClO、0.5%84、1%84消毒液调合藻酸盐印模材料消毒,在60min内不影响模型精度,可作为口腔印模的临床消毒方法。  相似文献   

8.
藻酸盐印模材取模的三维精度变化   总被引:2,自引:0,他引:2  
通过对石膏模型的定量测量评价六种牌号藻酸盐印模材的取模精度,实验金属模型模仿三单位固定义齿,在显微镜放大25倍下,对金属模型翻制的石膏模型上观测线交叉点的间距进行测量,测距包括:颊舌向(BL)、近远中向(MD)、(牙合)龈向(OG)和基牙间距离(IP).结果表明所有牌号的印模材制取的印模均无统计学上显著的三维尺寸变化,石膏模型精度临床可接受.但只有AP组印模材制取的石膏模型可补偿后续制做中的收缩.  相似文献   

9.
目的:比较2种调拌方式(人工,机调)下,2种藻酸盐印模材(金玛克专用,普通藻酸钾)精度的变化。方法:按调拌方式和印模材种类分4组:A组为自动调拌机调拌金玛克印模材;B组为自动调拌机调拌藻酸钾印模材;C组为人工调拌金玛克印模材:D组为人工调拌藻酸钾印模材。采用特制的金属模具取模后灌注石膏模型,再测量模型尺寸变化差值,所得数据进行统计分析。结果:采用机调的2种印模材精度均好于人工调拌组;而金玛克专用印模材在机调组中的精度好于普通藻酸钾印模材;人工调拌下金玛克印模材与普通藻酸钾印模材的精度差值差别并不显著。结论:使用自动调拌机调拌的印模材精度优于人工调拌,而以专用的印模材精度最高。  相似文献   

10.
目的评价2%酸性戊二醛浸泡消毒对藻酸盐印模表面的变形链球菌“C”、白色念珠菌、大肠杆菌、金黄色葡萄球菌和枯草杆菌黑色变种芽孢的消毒效果。方法制作5cm×5cm大小无菌印模试件,分成5组,分别用变形链球菌“C”、白色念珠菌、大肠杆菌、金黄色葡萄球菌和枯草杆菌黑色变种芽孢5种菌液污染。采用2%酸性戊二醛对染菌印模进行浸泡消毒处理,以蒸馏水浸泡作为对照组。其后不同时间在印模试件表面取样、接种、培养,并进行CFU计数,计算抑菌率。根据抑菌率大小评价消毒效果。结果2%酸性戊二醛浸泡消毒10min,可对藻酸盐印模表面的变形链球菌“C”、白色念珠菌、大肠杆菌和金黄色葡萄球菌达到有效消毒,在实验限定的作用时间内对枯草杆菌黑色变种芽孢消毒无效。结论2%酸性戊二醛浸泡为有效的印模消毒方法,但不能达到高水平的消毒。  相似文献   

11.
BackgroundThe authors conducted a study to determine if two irreversible hydrocolloid impression materials (Cavex ColorChange, Cavex Holland BV, Haarlem, Netherlands; Jeltrate Plus Antimicrobial Dustless Alginate Impression Material, Dentsply Caulk, Milford, Del.) stored for five days were dimensionally accurate.MethodsThe authors modified Ivorine teeth (Columbia Dentoform, Long Island City, N.Y.) on a Dentoform model (1560 series model, Columbia Dentoform) to allow measurements of tooth and arch width. They made impressions and generated casts immediately and at five additional times. They recorded tooth and arch widths on the casts and compared the measurements with those for the standard model.ResultsCompared with measurements for the model, the greatest measured difference in casts was 0.003 inches for Cavex ColorChange (extended-pour alginate) and 0.005 inches for Jeltrate Plus Antimicrobial Dustless Alginate Impression Material (conventional alginate). The percentage of dimensional change ranged from ?0.496 to 0.161 percent for the extended-pour alginate and from ?0.174 to 0.912 percent for the conventional alginate.ConclusionsResults of analysis of variance and paired t tests indicated that when generated immediately and at day 5, casts produced from both impression materials were not statistically different from the standard model (P < .05).Clinical ImplicationsWhen stored properly, both alginate materials can produce accurate impressions at day 5 for diagnostic casts and for fabrication of acrylic appliances.  相似文献   

12.
Glutaraldehyde and hypochlorite solutions have been shown to be effective disinfectants for use in the dental surgery. However, their use in the disinfecting of alginate hydrocolloid impression materials must be open to question since these materials are dimensionally unstable when immersed in aqueous solutions for any length of time. This project investigated the dimensional changes noted in casts poured into alginate impressions which had been stored for up to 60 minutes in either hypochlorite or glutaraldehyde solutions. All changes measured were considered to be within clinical tolerance.  相似文献   

13.
目的 对比顺时针调拌法与顺时针联合八字形调拌法对藻酸盐印模精确性的影响。方法 选取2018年3月—4月上海市浦东新区周浦医院口腔科固定单冠烤瓷牙修复病例40例,由2名护士与同一名医生对40例单冠烤瓷牙修复患者分别用2种调拌方式取制2套模型,分为实验组和对照组。对照组使用顺时针手工调拌方法制取模型,实验组使用顺时针联合八字形手工调拌方法制取模型。采用SPSS 24.0软件包对数据进行Mann-Whitney秩和检验。结果 由同一名高年资技师使用放大镜对制备的印模进行观察,记录肩台印迹、龈沟翼及气泡产生情况,综合评价印模质量。2组间比较差异有统计学意义(Z=-4.634,P<0.001)。其中,顺时针联合八字形调拌法印模质量Ⅰ级优秀比例(77.5%)显著高于顺时针调拌法(10%),Ⅳ级不合格比例(2.5%)显著低于顺时针调拌法(27.5%)。结论 使用顺时针联合八字形调拌法的印模质量显著高于顺时针调拌法,提高了取模的成功率,减少了重复印模给患者带来的不适。该技术的推广,有利于促进护理隐性知识的传播。  相似文献   

14.
目的 研究印模膏与3种藻酸盐印模材料之间的粘结强度.方法 用同一种尺寸(40 mm×30 mm×6 mm)的印模膏与3种不同藻酸盐印模材料结合后在万能试验机上测定印模膏与藻酸盐印模材料的粘结强度.结果 贺利氏藻酸盐印模材料新配方型(Heraplast NF)及红叶藻酸盐印模材料与贺利氏藻酸盐印模材料通用型(Heraplast BC)比较有显著差别(P<0.05).贺利氏藻酸盐印模材料新配方型与红叶藻酸盐印模材料相比较无差别(P>0.05).结论 贺利氏藻酸盐印模材料新配方型及红叶藻酸盐印模材料与印模膏粘结强度好.  相似文献   

15.
To ensure accuracy, alginate, impression materials must be firmly retained in the impression tray. This short report compares the effectiveness of perforated trays with a newly developed self-adhesive polyester fibre mat material which can be used to line the inner surface of stock and custom made impression trays. In all cases, the fibre mat was much more effective as a retention medium when compared with perforations. Also, small perforations proved more effective than larger ones for alginate retention.  相似文献   

16.
藻酸盐印模材料流动性能的比较研究   总被引:5,自引:1,他引:4  
目的 研究藻酸盐印模材料流动性能随时间变化的特点.方法 利用直径20 mm、高20 mm的圆柱形模具,将藻酸盐印模材料调拌放入其中,在不同时间施加0.7 kg的负荷,测量其直径表示其流动性大小.结果 两种藻酸盐印模材料均在30 s时流动性最好,其后流动性逐渐下降,但红叶藻酸盐印模材料在150 s后流动停止,贺利氏藻酸盐印模材料则在180 s后无流动性;两种藻酸盐印模材料的流动性差别有显著性统计学意义(P<0.01);同一种印模材料在各时间段的流动性差别有显著性统计学意义(P<0.01).结论 藻酸盐印模材料的流动性随着时间的延长而逐渐减弱,30 s时为取模的最佳时间.  相似文献   

17.
藻酸盐普通型印模材料用手工、调拌器和搅拌机(8 s)调和的操作时间分别为71、66、53 s;快凝型印模材料用手工、调拌器调和的操作时间分别为56 s和51s.普通型印模材料用手工、调拌器和搅拌机(8 s)调和的固化时间分别为163、160和124 s;快凝型印模材料用手工、调拌器调和的固化时间分别为131 s和121 s.普通型印模材料较适用于手工30 s、调拌器20s和搅拌机8 s调拌;快凝型印模材料较适用于手工30 s和调拌器20 s调拌.  相似文献   

18.
浸泡消毒对海藻酸盐印模三维尺寸稳定性影响的评价   总被引:6,自引:0,他引:6  
目的评价海藻酸盐印模分别接受2%酸性戊二醛、2%碱性戊二醛、2%强化中性戊二醛、84消毒液(有效氯含量为0.3%)的30分钟浸泡消毒处理后的三维尺寸稳定性的变化。方法采用同一个标准模型制取印模。实验分为四个消毒处理组,不处理组作为对照组。采用三维坐标扫描机分析消毒处理后的印模灌制出模型的尺寸改变,精确度可达0.001mm。结果除了2%强化酸性戊二醛处理组各项指标均与对照组没有显著性差异以外(P>0.05),其余三个消毒处理组均在水平向、垂直向和角度等方面与对照组出现显著性差异(P<0.05)。结论2%酸性戊二醛浸泡消毒30分钟,对海藻酸盐印模的三维尺寸稳定性没有显著性影响。  相似文献   

19.
目的研究托盘粘接剂对藻酸盐印模材料与不同材料托盘间粘接强度的影响。方法选择自凝树脂、光固化树脂和不锈钢3种托盘材料,每种材料分2组,一组涂布粘接剂,另一组不涂布粘接剂作为对照,总计6组,每组8个试件。采用藻酸盐通用型粘接剂以及临床常用的藻酸盐印模材料,装置在万能测力仪上进行拉力测试,所得数据用SAS软件进行统计分析。结果研究结果显示所有托盘材料中,应用托盘粘接剂组具有更高的粘接强度(P〈0.01)。不同托盘材料对粘接强度的影响具有统计学意义(P〈0.01)。结论在托盘表面应用粘接剂能改善印模材料和托盘的粘接强度,涂布粘接剂前后不锈钢材料托盘的粘接强度均大于树脂。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏