首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 281 毫秒
1.
Acute displacement at cement-prosthesis interface of a polished femoral component of hip arthroplasty occurring as a consequence of attempted closed manipulation is rare. This complication can be avoided by placing cement over the shoulder of the prosthesis and using fluoroscopic control during closed manipulation if there is a dislocation.  相似文献   

2.
《The Journal of arthroplasty》2022,37(11):2208-2213
BackgroundThe aim of this study was to compare the stem alignment and the quality of cement mantle of collarless polished tapered cemented stems inserted through the direct anterior approach (DAA) and the direct lateral approach (DLA).MethodsA comparative retrospective study of 232 hybrid total hip arthroplasties using a cemented collarless polished tapered stem through either the DAA (n = 147) or DLA (n = 85) was performed. Radiographic evaluation included stem alignment, cement mantle quality, and cement mantle thickness.ResultsOn anteroposterior radiographs, stems implanted through the DLA were more likely to be in neutral alignment, than those implanted through the DAA (83.5%[n = 71] versus 71.4% [n = 105]; P = <.001). No difference between approaches was noted for stem alignment on lateral radiographs or cement mantle quality. Multivariate analysis revealed factors associated with suboptimal cement mantle and included Dorr type B or C femur as well as male gender. A mean cement mantle thickness ≥2mm was achieved in all Gruen zones for both approaches.ConclusionIn our series, the DAA was associated with a higher incidence of coronal plane stem malalignment compared to the DLA when using cemented tapered polished femoral components for total hip arthroplasty. No difference in lateral stem alignment or cement mantle quality was found.  相似文献   

3.
4.
Total hip arthroplasty can be performed successfully using cement or cementless technology. Cemented femoral stems can achieve enduring long-term suvivorship as long as meticulous surgical technique is utilized and patient selection is appropriate. Cemented acetabular components should only be utilized in patients with less than 10 years of remaining life expectancy. Critical risk factors for cemented total hip arthroplasty include atrophic osteoarthrtis on the acetabular side and unfavorable femoral geometry for the femoral stem such as "the stove-pipe" canal. Rapid polyethylene wear and osteolysis are rarely seen in contemporary cemented total hip arthroplasty performed with a smooth, tapered, collarless femoral stem with a highly polished head and a well-designed acetabular component.  相似文献   

5.
Impaction bone grafting for total hip revision   总被引:3,自引:2,他引:1  
We used impaction bone grafting for total hip revision on 26 hips in 25 patients. Average patient age was 68 (34-89) years, and average duration from last surgery was 9 years. In all cases morselized allograft bone was used for the graft, and the femoral component was a collarless, polished, tapered stem. Average duration of surgery was 2.4 h, intraoperative blood loss 600 cc, blood replacement 2.4 units, and acute-care hospital stay 5 days. Complications were varus placement of the stem in two patients and postoperative development of varus in one, one intraoperative and three postoperative femoral fractures, and one postoperative dislocation. Average subsidence was 0.6 cm. We believe that most, if not all, of these complications could have been prevented.  相似文献   

6.
Acute displacement at the cement—prosthesis interface of the femoral component of a hip arthroplasty that occurred as a consequence of attempted reduction of a dislocation is described. Although this complication is theoretically possible with a polished tapered stem design, it is previously unrecognized, and may be avoidable if fluoroscopic control is used during closed reduction of a dislocation.  相似文献   

7.
The clinical and radiographic outcomes of the cement-within-cement femoral stem exchange technique at revision hip arthroplasty were determined. Twenty-three revisions with a collarless polished double-taper stem design were prospectively monitored at up to 12 years. The most common indications for revision were recurrent dislocation and acetabular revision. Radiographic stem subsidence was measured by the Ein Bild Röentgen Analyse method. There was no stem re-revision and no radiographic loosening. Stem within cement subsidence, an intentional design feature of this stem, averaged 0.8 mm (range, 0-2 mm). The average subsidence was similar to that in primary hip arthroplasty. The excellent long-term results of cemented collarless polished taper stems for primary and revision hip arthroplasty can be extended even further by cement-within-cement exchange, which preserves the femur.  相似文献   

8.
The clinical and radiologic outcome of a cemented, polished, tapered stem (CPT), implanted using contemporary cementing techniques in 108 consecutive operated hips in 100 patients (68 women and 32 men, aged 19 to 83 years at the time of surgery [mean, 65 years]) was assessed after >5 years. The Harris hip scores were good or excellent in 96% of the patients. Stem subsidence measured by the computer-assisted method described by Braud and Freeman was at a mean rate of 0.44 mm/y, 1.08 mm during the first year, and stabilizing to a mean total of 2.18 mm at >5 years. Subsidence was related inversely to the completeness of the cement mantle but did not correlate with the clinical or radiologic outcome. This study confirms that collarless, polished, tapered stems subside within the cement mantle but without loosening and that the CPT performs at least as well as the Exeter stem.  相似文献   

9.
Displacement of a polished stem while attempting closed reduction of a dislocated total hip or during dislocation itself is a rare but significant complication. Our aim was to assess whether applying bone cement over the shoulder of the implant can help to prevent this. We conducted an in vitro mechanical study with tensile testing machine. We cemented 7 sawbones with a standard cementing technique and another 7 with additional cement over the shoulder of the implant. The mean pull-out force in the routine cementing technique was 2066 N (SD, 256.65), and it was 3220 N (SD, 312.22) for the group with the cement on the shoulder. There is a statistically significant difference of 1154 N. We recommend that when a polished stem is used, bone cement should be applied over the shoulder of the implant.  相似文献   

10.
We prospectively followed 191 consecutive collarless polished tapered (CPT) femoral stems, implanted in 175 patients who had a mean age at operation of 64.5 years (21 to 85). At a mean follow-up of 15.9 years (14 to 17.5), 86 patients (95 hips) were still alive. The fate of all original stems is known. The 16-year survivorship with re-operation for any reason was 80.7% (95% confidence interval 72 to 89.4). There was no loss to follow-up, with clinical data available on all 95 hips and radiological assessment performed on 90 hips (95%). At latest follow-up, the mean Harris hip score was 78 (28 to 100) and the mean Oxford hip score was 36 (15 to 48). Stems subsided within the cement mantle, with a mean subsidence of 2.1 mm (0.4 to 19.2). Among the original cohort, only one stem (0.5%) has been revised due to aseptic loosening. In total seven stems were revised for any cause, of which four revisions were required for infection following revision of the acetabular component. A total of 21?patients (11%) required some sort of revision procedure; all except three of these resulted from failure of the acetabular component. Cemented acetabular components had a significantly lower revision burden (three hips, 2.7%) than Harris Galante uncemented components (17 hips, 21.8%) (p < 0.001). The CPT stem continues to provide excellent radiological and clinical outcomes at 15?years following implantation. Its results are consistent with other polished tapered stem designs.  相似文献   

11.
Displacement of the polished stem of a total hip arthroplasty from its cemented mantle occurred as a complication of an attempted closed reduction after luxation. No cement fractures were seen during subsequent reoperation. The complication can be avoided if cement is placed over the shoulder of the prosthesis.  相似文献   

12.
We retrospectively reviewed 175 patients (191 hips) who had undergone primary cemented total hip replacement between November 1992 and November 1995 using a collarless polished double-tapered femoral component after a minimum of ten years (mean 11.08; 10 to 12.8). All stems were implanted using contemporary cementing techniques with a distal cement restrictor, pressurised lavage, retrograde cementing with a gun and proximal pressurisation. Clinical outcome was assessed using the Harris Hip score. Radiological analysis was performed on calibrated plain radiographs taken in two planes. Complete radiological data on 110 patients (120 hips) and clinical follow-up on all the surviving 111 patients (122 hips) was available. The fate of all the hips was known. At final follow-up, the mean Harris Hip score was 86 (47 to 100), and 87 of 116 patients (75%) had good or excellent scores. Survival with revision of the stem for aseptic loosening as the endpoint was 100%; and survival with revision of the stem for any reason was 95.9% (95% confidence interval 87.8 to 96.8) at ten years. All the stems subsided vertically at the stem-cement interface in a predictable pattern, at an overall mean rate of 0.18 mm per year (0.02 to 2.16), but with a mean rate of 0.80 mm (0.02 to 2.5) during the first year. The mean total subsidence was 1.95 mm (0.21 to 24). Only three stems loosened at the cement-bone interface. There was excellent preservation of proximal femoral bone stock. There was a high incidence of Brooker III and IV heterotopic ossification affecting 25 patients (22%). The collarless polished tapered stem has an excellent clinical and radiological outcome at a minimum of ten years' follow-up. The pattern and magnitude of subsidence of the stem within the cement mantle occurred in a predictable pattern, consistent with the design philosophy.  相似文献   

13.
Impacting morcellized allograft bone into the femur during revision total hip arthroplasty is a simple concept with the goal of rebuilding femoral bone stock and providing secure fixation to the femoral stem. Using the collarless polished tapered (CPT, Zimmer, Warsaw, IN) stem impaction grafting system, we became concerned about the discrepancy between the straightforward concept and precise execution of the technique. In this study, we examined 31 consecutive procedures to determine intraoperative difficulties and report on the clinical outcome of 30 cases at an average follow-up of 31 months. Modified Harris Hip Scores averaged 41 points preoperatively and improved to 86 points at follow-up. Nineteen cases were performed on intact femora, whereas 12 cases had disrupted femoral integrity, either extended trochanteric osteotomy or periprosthetic fracture. Successful outcome was seen in all cases with an intact femur, and restoration of femoral integrity was key to successful outcome in cases with compromised femoral integrity. Among cases with disrupted femoral integrity, 3 distal fractures occurred as a result of the rigid CPT cement plug, and 2 complete femoral fractures occurred as a result of bone impaction, for a technique-related fracture rate of 16%. Difficulty packing bone distally occurred in 94% of cases and was associated with varus and valgus stem alignment and medial and lateral stem displacement. Complete cement mantles were seen in 77% of cases. No stem subsidence was seen in 15 of 30 cases (50%). Stem subsidence of <5 mm was seen in 10 of 30, stem subsidence of 6 to 8 mm was seen in 4 of 30, and stem subsidence of >10 mm was seen in 1 patient (4%). Of the patients, 87% thought the procedure improved their function, and 97% would recommend it to a friend with a failed femoral component. Although we hope that the instruments for this procedure can improve, we endorse the concept of impaction grafting with the CPT stem as a successful way of dealing with revision femoral surgery.  相似文献   

14.
A goat model of revision hip arthroplasty was used to examine the histology and mechanical performance of impaction grafting using two femoral stems varying in stem surface finish. There were no significant mechanical or qualitative histologic differences between smooth, tapered, polished stems and step-cut, grit-blasted stems. Allograft distribution, bone incorporation, and cement mantle thickness were not uniform within the femoral canal. Efforts to improve the impaction grafting technique may be more important than stem design.  相似文献   

15.
目的探讨半髋置换股骨柄在股骨近端髓腔不同形态固定方式对高龄股骨颈骨折疗效的影响。 方法回顾分析2007年1月至2017年2月在东莞市人民医院关节外科分别连续收治的75岁以上高龄股骨颈骨折患者100例,纳入标准:Garden Ⅲ、Ⅳ型、骨折前尚能独立行走;排除标准:股骨颈病理性骨折、同侧髋骨关节炎、严重内科疾病不能耐受手术。分为骨水泥组和生物组。骨水泥组行骨水泥股骨柄双动头置换术,生物组行生物双动头置换术,对比骨水泥组与生物组术中并发症,术后假体周围骨折情况,股骨近端髓腔Noble分型,股骨假体的初始位置,假体松动情况及其末次随访时的髋关节功能Harris评分差异,计量资料对比采用t检验,计数资料比较采用卡方检验。 结果100例患者均获得随访平均(15 ± 3)个月。骨水泥组术中出现明显骨水泥反应2例,未出现死亡病例,术后有2例出现假体周围骨折(Vancouver分型VB2型和VC型)。生物组术中出现股骨距骨折6例(Vancouver分型VAL型),术后假体周围骨折2例(Vancouver分型均为B2型),术后3个月内出现髋关节后脱位1例。术后3个月内死亡2例,均为肾功能衰竭患者。股骨柄的位置安放在内或外翻位>3°为异常时,100例中仅生物组1例烟囱型髓腔出现内翻位置达4°,异常率仅为1%。骨水泥型股骨柄容易出现外翻位放置,生物型股骨柄容易出现内翻位放置。术后末次随访髋关节功能Harris评分骨水泥组和生物组优良率分别为89%和83%,两组差异无统计学意义(χ2=0.44,P>0.05)。 结论生物无领矩形股骨柄(LCU股骨柄)与有领骨水泥股骨柄(Classic股骨柄)双动头置换治疗高龄股骨颈骨折患者在股骨近端不同类型的髓腔中均能获得良好的治疗效果。  相似文献   

16.
The purpose of this study was to evaluate the osseointegration potential and implant-related complications of cementless total hip arthroplasty with a titanium alloy collarless, tapered, wedge-shaped femoral stem with a proximal circumferential plasma-spray coating in patients with acute hip fractures. The cohort consists of 85 patients with a mean age of 78.1 years. The mean duration of follow-up was 3.8 years. Total hip arthroplasty conferred significant improvement in function for all patients. All femoral components were stable with evidence of bone ingrowth (84 hips) or fibrous fixation (1 hip). Mild thigh pain was present in 3 patients. The complications included dislocation (3 cases), intraoperative femoral fracture (2 cases), and periprosthetic femoral fracture in the postoperative period (1 case). There was one reoperation for revision of the femoral component in the patient with a periprosthetic fracture. There were 25 (29%) deaths. Cementless total hip arthroplasty using a tapered proximally coated femoral stem is a viable option for the treatment of a displaced hip fracture and preexistent arthritis.  相似文献   

17.
This prospective review aimed to evaluate 15-year survivorship of the collarless, third-generation cemented, normalized, Omnifit (Osteonics, Allendale, NJ) femoral stem in hybrid total hip arthroplasty (THA). Between January 1986 and June 1990, a single surgeon prospectively implanted 250 consecutive hybrid THAs (215 patients) using a modified third-generation cement technique in selected patients. A Harris-Galante (I or II) (Zimmer, Warsaw, IN) cementless shell with modular polyethylene (4150 resin) liners gamma-sterilized in air were implanted. Kaplan-Meier survivorship of the femoral or acetabular component with mechanical failure (revision for aseptic loosening) as the end-point was 100% ± 0% at 15 years. Wear couple exchange and bone grafting was performed in 1 case (0.4%) for progressive acetabular osteolysis. This report supports femoral component centralization and good cement mantle to ensure durability of the collarless, cemented, normalized femoral stem with a surface roughness of 30–40 microinches.  相似文献   

18.
Displacement of a cemented femoral stem during attempted closed reduction of a dislocated total hip arthroplasty has been anecdotally described in the literature. All these reports involved use of cemented, highly polished, tapered stems. We report, the first to our knowledge, a case of displacement of a cemented, textured femoral stem, during attempted closed reduction. The case is being reported not only for its rarity but also to alert treating surgeons of this devastating complication which can expose the patient to the risks of open surgery. Gentle reduction, using the gravity method of Stimpson, under fluoroscopy control, may be safer and prevent this complication from occurring. If the cement mantle is intact, cement-within-cement is a reliable, quick, and simple technique to overcome this difficult problem.  相似文献   

19.
《Acta orthopaedica》2013,84(5):427-432
Background and purpose — Straight collarless polished tapered stems have been linked to an increased risk for periprosthetic femur fractures in comparison with anatomically shaped stems, especially in elderly patients. Therefore, we evaluated the effect of an orthopedic department’s full transition from the use of a cemented collarless, polished, tapered stem to a cemented anatomic stem on the cumulative incidence of postoperative periprosthetic fracture (PPF).

Patients and methods — This prospective single-center cohort study comprises a consecutive series of 1,077 patients who underwent a cemented hip arthroplasty using either a collarless polished tapered stem (PTS group, n = 543) or an anatomic stem (AS group, n = 534). We assessed the incidence of PPF 2 years postoperatively and used a Cox regression model adjusted for age, sex, ASA class, cognitive impairment, BMI, diagnosis, and surgical approach for outcome analysis.

Results — Mean age at primary surgery was 82 years (49–102), 73% of the patients were female, and 75% underwent surgery for a femoral neck fracture. The PPF rate was lowered from 3.3% (n = 18) in the PTS group to 0.4% (n = 2) in the AS group. The overall complication rate was also lowered from 8.8% in the PTS group to 4.5% in the AS group. In the regression model only cognitive dysfunction (HR 3.8, 95% CI 1.4–10) and the type of stem (PTS vs AS, HR 0.1, CI 0.0–0.5) were correlated with outcome.

Interpretation — For elderly patients with poor bone quality use of cemented anatomic stems leads to a substantial reduction in periprosthetic fracture rate without increasing other complications.  相似文献   

20.
Dislocation is a possible complication after primary and revision hip arthroplasty. Closed reduction is the first treatment option. Displacement of polished Exeter stem from a cement mantle during closed reduction of dislocated hip after revision hip arthroplasty is described. The patient was re-operated, new non-polished stem was cemented without any further complications. Placement of the cement mantle over superior and lateral part of the stem may prevent such complication.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号