首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到18条相似文献,搜索用时 203 毫秒
1.
目的 比较飞秒激光制瓣准分子激光原位角膜磨镶术(femtosecond-assisted laser in situ keratomileusis,FS-LASIK)与小切口飞秒激光基质透镜切除术(small incision lenticule extraction,SMILE)术后角膜高阶像差的变化。方法 选取行FS-LASIK患者22例(22眼)及行SMILE患者30例(30眼)作为研究对象,测量并对比2种术式患者术前及术后1周、1个月的角膜波前像差。结果 FS-LASIK术后1周球差、倾斜三叶草分别为(0.517±0.193)μm、(0.096±0.146)μm,与术前相比均增大,差异均有统计学意义(均为P<0.05)。FS-LASIK术后1个月球差、水平彗差、倾斜三叶草分别为(0.534±0.178)μm、(0.151±0.263)μm、(0.088±0.152)μm,与术前相比均增大,差异均有统计学意义(均为P<0.05)。SMILE术后1周球差、倾斜三叶草分别为(0.361±0.189)μm、(0.017±0.147)μm,与术前相比均增大,差异均有统计学意义(均为P<0.05)。SMILE术后1个月球差为(0.382±0.178)μm,与术前相比增大,差异有统计学意义(P<0.05)。术后1个月2组间球差、倾斜三叶草、总高阶像差均方根值差异均有统计学意义(t=3.043、2.647、2.391,均为P<0.05)。结论 FS-LASIK术后早期角膜高阶像差改变以球差、彗差、倾斜三叶草为主;SMILE术后早期角膜高阶像差改变以球差为主。FS-LASIK和SMILE术后早期球差、倾斜三叶草、总高阶像差有显著差异。  相似文献   

2.
目的 对比和评价SMILE和飞秒激光制瓣的LASIK (FS-LASIK)矫正近视的效果.方法 前瞻性对照研究.71例患者(142眼)分为2组:SMILE组36例和FS-LASIK组35例.术前及术后1d、7d、1个月、3个月、6个月分别检查记录2组患者的UCVA和屈光度,并用Zywave波前像差仪检查总高阶像差、球差、三阶垂直彗差、三阶水平彗差.对数据进行卡方检验和独立样本t检验.结果 术后1 d FS-LASIK组UCVA较SMILE组好,术后7d、1个月时2组UCVA相近,术后3个月后,SMILE组显示出较FS-LASIK组更好的UCVA,术后不同时间点2组UCVA≥术前BCVA的比例差异均无统计学意义;术后7d和6个月时2组等效球镜度差异均无统计学意义(t=0.56、0.41,P>0.05);2组术后早期总高阶像差均较术前明显增加,术后3个月有所下降,术后6个月SMILE组低于FS-LASIK组;2组术后1d、7d、1个月、3个月球差均较术前明显增加,术后6个月有所下降,但仍高于术前水平;术后2组垂直彗差均较术前增加,术后3个月开始有所下降,术后6个月时接近于术前;术后各时间点2组水平彗差较术前均明显增加.术后不同时间点2组总高阶像差、球差、垂直彗差、水平彗差相比较差异均无统计学意义.结论 SMILE和FS-LASIK矫正近视安全、有效,术后均有较好的视力矫正效果;2种手术都会造成总高阶像差、球差、彗差的增加.  相似文献   

3.
目的比较飞秒激光小切口角膜基质透镜取出术(SMILE)与飞秒激光制瓣准分子激光原位角膜磨镶术(FS-LASIK)矫正近视及近视散光术后视觉质量的差异。方法前瞻性非随机对照研究。选取2015年1-6月于武汉爱尔眼科汉口医院屈光手术中心行SMILE的近视患者41例(41眼)作为SMILE组,行FS-LASIK的近视患者37例(37眼)作为FS-LASIK组。所有患者于术前,术后1 d、1个月及3个月行裸眼视力(UCVA)、综合验光检查,并于术前、术后3个月行角膜像差检查。应用重复测量的方差分析、配对样本t检验、独立样本t检验、卡方检验对数据进行分析。结果2组患者UCVA及等效球镜度(SE)在术后1 d、1个月和3个月差异均无统计学意义。术后3个月,FS-LASIK组95%患者SE在±0.50 D范围内,SMILE组98%患者SE在±0.50 D范围内,差异无统计学意义。术后不同时间点2组间UCVA达到5.0及更好的百分比差异均无统计学意义。在6 mm瞳孔直径下,SMILE组患者术后3个月时的角膜总高阶像差、彗差及球差分别为(0.54±0.13)µm、(0.29±0.14)µm、(0.32±0.12)µm,均显著低于FS-LASIK组[分别为(0.71±0.45)µm、(0.48±0.42)µm、(0.47±0.38)µm],差异有统计学意义(t=1.60、2.00、1.66,P<0.05)。结论SMILE与FS-LASIK矫正近视及近视散光均有良好的安全性和有效性,且SMILE术后高阶像差的改变比FS-LASIK小,术后视觉质量更佳。  相似文献   

4.
目的:比较飞秒激光小切口角膜基质透镜取出术(SMILE)与飞秒激光制瓣准分子激光原位角膜磨镶术(FS-LASIK)矫正近视及散光术后的视觉质量。方法:前瞻性非随机对照研究。选取2015 年11 月至2016 年2 月在长沙爱尔眼科医院屈光中心接受飞秒激光屈光手术的近视散光患者162 例(324 眼),按患者选择的手术方式不同分为SMILE组78例(156眼)和FS-LASIK组84例(168眼)。术后随访6个月,分别比较2组患者术后1 d、1个月、6个月的裸眼视力(UCVA)、等效球镜度(SE)以及术后3个月的角膜像差及切削中心偏移量。在术后1、6 个月时对2 组患者进行视觉质量问卷调查,调查问卷为简化后的视觉质量量表。采用重复测量方差分析、单因素方差分析、卡方检验、秩和检验对数据进行统计分析。结果:SMILE组术后1 d的UCVA低于FS-LASIK组(t=4.555,P < 0.001),术后1、6 个月2组间UCVA差异无统计学意义。术后1 d SMILE组SE大于FS-LASIK组(t=-2.952,P=0.003),术后1、6个月2组间差异无统计学意义。2组术后3个月角膜总高阶像差、球差、彗差、三叶草差均较术前增加(均P < 0.05),SMILE组术后3个月球差、三叶草差大于FS-LASIK组,差异有统计学意义(t= 5.633,P < 0.001;t=2.586,P=0.010)。SMILE组术后3个月切削中心偏移量为(0.17 ± 0.09)mm,FS-LASIK组为(0.18 ± 0.10)mm,组间差异无统计学意义。与术后1 个月相比,SMILE组术后6 个月光晕发生比例明显减轻(χ2=5.547,P=0.019),程度明显减轻(Z=-2.283,P=0.022),而FS-LASIK组各项症状发生比例差异无统计学意义。术后1、6 个月2 组间各项症状发生眼数及得分差异均无统计学意义。结论:与FS-LASIK手术相比,SMILE术后早期视力恢复较慢,球差和三叶草差增加更多,偏中心切削和不良视觉症状的发生无明显差异。  相似文献   

5.
比较飞秒激光小切口角膜基质透镜取出术(SMILE)与飞秒激光制瓣准分子激光原位角膜磨镶术(FS-LASIK)的术后偏心量,分析偏心量与术后角膜高阶像差、Kappa角、等效球镜度(SE)、主导眼的相关性。方法:回顾性研究。选取2018年1-10月在广州爱尔眼科医院行SMILE的患者62例(124眼),行FS-LASIK的患者44例(88眼)。在Pentacam术后3个月的切线曲率图(Tangential curvature [front])上,用自制的透明同心圆环拟合6 mm左右光学区边界,圆心距角膜顶点的距离记为偏心量。应用独立样本t检验、Pearson线性相关分析、卡方检验处理数据。结果:术后3个月SMILE组偏心量为(0.27±0.14)mm,FS-LASIK组为(0.25±0.13)mm,组间差异无统计学意义;FS-LASIK组偏心量与术后彗差有相关性(r=0.288,P=0.009),SMILE组偏心量与术后彗差、球差及FS-LASIK组偏心量与术后球差均无相关性。2组偏心量与Kappa角、SE均无相关性。组内主导眼与非主导眼偏心量差 异无统计学意义。结论:SMILE的手动切削中心定位方式与FS-LASIK的自动化切削中心定位方式精确度相仿;偏心量会影响FS-LASIK术后彗差,对SMILE无影响;且2种术式偏心量均不受Kappa角、SE、主导眼的影响。  相似文献   

6.
目的:对比和分析飞秒激光小切口角膜基质透镜取出术(SMILE)、飞秒激光制瓣准分子激光原位角 膜磨镶术(FS-LASIK)和准分子激光上皮瓣下角膜磨镶术(LASEK)矫正高度近视术后角膜后表面高 度(PCE)的变化。方法:回顾性病例对照研究。纳入2017年1月至2019年12月就诊于山东第一医科 大学附属眼科医院的高度近视患者共144例(144眼),分为3组,每组各48例(48眼),分别行SMILE、 FS-LASIK及LASEK。采用Pentacam三维眼前节分析系统分析术前及术后1、3、6个月角膜顶点PCE 及2 mm、4 mm直径平均PCE。角膜后表面高度变化量(△PCE)为术后PCE与术前PCE差值。采用 重复测量方差分析对组内及3组间PCE和△PCE进行比较。术后6个月采用Pearson相关分析对3组 △PCE与中央角膜厚度(CCT)、透镜厚度/切削深度(LT/AD)及剩余基质床厚度(RBT)进行分析。 结果:3组PCE仅在角膜4 mm直径处差异有统计学意义(F=7.79,P<0.001),术后6个月,SMILE及 FS-LASIK组PCE小于LASEK组(F=9.75,P<0.001)。3组△PCE在角膜各区域均差异无统计学意义。 LASEK组角膜中央后表面术后1个月较术前轻微后移(P=0.001),至术后6个月时回弹至术前高度。 SMILE组及LASEK组术后1个月4 mm直径角膜后表面较术前均有轻微前移(P<0.05),至术后6个月 维持稳定。FS-LASIK组PCE在角膜各区域及手术前后各时间点差异均无统计学意义。FS-LASIK组2 mm环及4 mm环△PCE与AD呈轻度正相关(r=0.31,P=0.029;r=0.30,P=0.039),其余参数间均无相 关性。结论:SMILE、FS-LASIK及LASEK矫正高度近视后,角膜后表面高度变化无差异;3种方式 矫正高度近视后角膜后表面高度均有较好的稳定性。  相似文献   

7.
比较飞秒激光制瓣准分子激光原位角膜磨镶术(FS-LASIK)与飞秒激光小切口角膜基质透镜取出术(SMILE)术后不同时间点干眼参数与角膜知觉的变化,探讨不同手术方式对泪膜及角膜知觉的影响并分析2项指标之间的相关性。方法:前瞻性非随机对照研究。行FS-LASIK患者24例(48眼),行SMILE患者21例(41眼)。在术前及术后1、3个月采用Keratograph 5M眼表综合分析仪行泪河高度(TMH)、非入侵性泪膜破裂时间(NIBUT)[包括首次泪膜破裂时间(NIF-BUT)与平均泪膜破裂时间(NIAvg-BUT)]的检查,并进行中央角膜知觉检查。组内手术前后各观察指标的比较采用重复测量方差分析;组间一般资料及各观察指标的比较用独立样本t检验;角膜知觉与干眼参数的相关性采用 Spearman相关分析。结果:2组间术前各干眼参数与中央角膜知觉差异均无统计学意义。FS-LASIK 组与SMILE组TMH在术后1个月和3个月较术前均下降(F=21.213,P<0.001;F=14.648,P<0.001), SMILE组术后2 个时间点的TMH高于FS-LASIK组(t=-5.549,P<0.001;t=-3.028,P=0.003)。 FS-LASIK组NIF-BUT术后1个月较术前下降(F=4.603,P=0.019);而SMILE组NIF-BUT在术后2个时间点较术前值虽下降,但差异无统计学意义(F=0.599,P=0.516);术后1个月SMILE组NIF-BUT优 于FS-LASIK组(t=-3.430,P=0.001)。FS-LASIK组NIAvg-BUT在术后1个月较术前下降(F=3.580, P=0.042);SMILE组NIAvg-BUT术后2个时间点较术前虽下降,但差异均无统计学意义(F=0.274, P=0.761);SMILE组NIAvg-BUT 2 个时间点均在术后优于FS-LASIK组(t=-2.395,P=0.019; t=-2.431,P=0.017)。FS-LASIK组中央角膜知觉术后各时间点较术前下降,术后3个月高于术后1个月(F=121.919,P<0.001);SMILE组中央角膜知觉术后1个月较术前下降(F=54.032,P<0.001);术后各时间点SMILE组均优于FS-LASIK组(t=-5.367,P<0.001;t=-3.242,P=0.002)。2组术后各时间点中央角膜知觉与干眼参数均呈正相关性(均P<0.05)。结论:FS-LASIK和SMILE组的干眼参数与中央角膜知觉均会出现不同程度的下降,患者行SMILE术后干眼参数与中央角膜知觉优于行FS-LASIK 者,且中央角膜知觉与干眼参数均呈正相关性。  相似文献   

8.
目的 比较飞秒激光小切口角膜基质透镜取出术(SMILE)与飞秒激光辅助准分子激光原位角膜磨镶术(FS-LASIK)治疗高度近视散光患者5年的临床疗效。方法 前瞻性非随机对照研究。根据所接受的手术方式不同患者被分为SMILE组和FS-LASIK组,术后随访5年,对比分析两组患者裸眼远视力(UDVA)、最佳矫正远视力(BCDVA)、等效球镜度(SE)、散光、总高阶像差(HOAs)、球差、彗差、泪液分泌功能、泪膜破裂时间(TBUT)和眼表疾病指数量表(OSDI)评分。采用重复测量资料的方差分析进行统计学分析,采用LSD-t检验进行两两比较,采用独立样本t检验进行组间分析。结果 2组患者相比,术后UDVA、SE、HOAs、球差、彗差、泪液分泌试验、TBUT、OSDI评分差异均有统计学意义(均为P<0.05),但BCDVA、散光的差异均无统计学意义(均为P>0.05)。SMILE组患者术后1个月的SE低于FS-LASIK组,而术后1~5年的SE均高于FS-LASIK组(均为P<0.05)。SMILE组患者术后3~6个月、3~5年的HOAs均较FS-LASIK组更低(均为P<...  相似文献   

9.
目的 比较飞秒激光FS200制瓣辅助的LASIK(FS-LASIK)和角膜板层刀制瓣的前弹力层下激光角膜磨镶术(SBK)的临床效果及角膜像差变化.方法 前瞻性病例对照研究.34例(68眼)应用FS200飞秒激光制瓣(FS组)患者和45例(90眼)M2微型角膜板层刀制瓣(SBK组)患者纳入研究.术前及术后1、3个月分别检查记录2组患者的裸眼视力、屈光度、矫正视力,并采用Pentacam-HR眼前节分析系统,对术眼进行眼前节扫描获得三维图像,通过内置分析软件获取瞳孔直径为6 mm的角膜总高阶像差(HOA)、球差(C40)、水平彗差(C31)、垂直彗差(C3-1)和水平三叶草(C33)、斜向三叶草(C3-3)数据,采用方差分析及t检验进行统计分析.结果 FS组角膜HOA、C40、C3-1手术前后比较差异均有统计学意义(F=8.511、12.356、11.843,P<0.01);SBK组角膜HOA、C40、C3-1、C31差异也存在统计学意义(F=46.601、38.627、10.874、11.727,P<0.01).术后1个月时SBK组HOA的增高幅度明显高于FS组,差异有统计学意义(t=3.063,P<0.05),术后3个月仍有同样趋势(t=2.998,P<0.05).术后1个月时2组患者角膜球差均有增高,组间差异无统计学意义(t=-1.990,P>0.05),而3个月时FS组有所恢复,组间差异有统计学意义(t=-2.666,P<0.05).2组三叶草像差(C33、C33)均较术前增加,术后1、3个月斜向三叶草(C3-3)与术前比较差异有统计学意义,但组间比较差异无统计学意义.结论 FS-LASIK和SBK均可造成角膜总高阶像差、球差、垂直彗差的增加,但FS-LASIK角膜总高阶像差和球差的增幅比SBK小,在提高视觉质量方面飞秒可发挥更大的作用.  相似文献   

10.
观察飞秒激光辅助制瓣准分子激光原位角膜磨镶术(FS-LASIK)联合节约角膜切削厚度的 Triple-A切削模式矫正超高度近视的临床疗效。方法:前瞻性临床研究。选取2016年1-7月于南京中医药大学附属医院接受角膜屈光手术的高度近视患者92例(184眼),根据等效球镜度(SE)分为高度近视组(-9.0 D0.05)。术后6个月,2组有效性指数和安全性指数差异无统计学意义(均P>0.05)。2组术后均有远视漂移,超高度近视组早期更为显著,2组在术后3个月屈光度趋于稳定。高度近视组和超高度近视组术后角膜总高阶像差、球差和水平彗差引入量在时间上和组别间差异有统计学意义(P<0.05),角膜垂直彗差引入量在时间上和组别间差异无统计学意义。结论:FS-LASIK联合Triple-A切削模式矫正高度近视和超高度近视都能够有效地改善患者的视力,有较好的安全性、有效性和稳定性。  相似文献   

11.
AIM: To evaluate the possible differences in visual quality between small-incision lenticule extraction (SMILE) and femtosecond laser-assisted LASIK (FS-LASIK) for myopia. METHODS: A Meta-analysis was performed. Patients were from previously reported comparative studies treated with SMILE versus FS-LASIK. The PUBMED, EMBASE, Cochrane, Web of Science and Chinese databases (i.e. WANFANG and CNKI) were searched in Nov. of 2016 using RevMan 5.1 version software. The differences in visual acuity, aberration and biomechanical effects within six months postoperatively were showed. Twenty-seven studies including 4223 eyes were included. RESULTS: No significant differences were observed between SMILE and FS-LASIK in terms of the proportion of eyes that lost one or more lines of corrected distance visual acuity after surgery (P=0.14), the proportion of eyes achieving an uncorrected distance visual acuity of 20/20 or better (P=0.43), the final refractive spherical equivalent (P=0.89), the refractive spherical equivalent within ±1.00 diopter of the target values (P=0.80), vertical coma (P=0.45) and horizontal coma (P=0.06). Compared with the FS-LASIK group, total higher-order aberration (tHOA) (P<0.001) and spherical aberration (P<0.001) were higher and the decrease in corneal hysteresis (CH) (P=0.0005) and corneal resistance factor (CRF) (P=0.02) were lower in the SMILE group. CONCLUSION: SMILE and FS-LASIK are comparable in efficacy, safety and predictability for correcting myopia. However, the aberration in the SMILE group is superior to that in the FS-LASIK group, and the loss of biomechanical effects may occur less frequently after SMILE than after FS-LASIK.  相似文献   

12.
AIM: To evaluate the possible differences in visual quality between small incision lenticule extraction (SMILE) and femtosecond laser in situ keratomileusis (FS-LASIK) for myopia. METHODS: A Meta-analysis was performed. Patients were from previously reported comparative studies treated with SMILE versus FS-LASIK. The PubMed, EMBASE, Cochrane, Web of Science and Chinese databases (i.e. WANFANG and CNKI) were searched in Nov. of 2016 using RevMan 5.1 version software. The differences in visual acuity, aberration and biomechanical effects within six months postoperatively were showed. Twenty-seven studies including 4223 eyes were included. RESULTS: No significant differences were observed between SMILE and FS-LASIK in terms of the proportion of eyes that lost one or more lines of corrected distance visual acuity after surgery (P=0.14), the proportion of eyes achieving an uncorrected distance visual acuity of 20/20 or better (P=0.43), the final refractive spherical equivalent (P=0.89), the refractive spherical equivalent within ±1.00 diopter of the target values (P=0.80), vertical coma (P=0.45) and horizontal coma (P=0.06). Compared with the FS-LASIK group, total higher-order aberration (P<0.001) and spherical aberration (P<0.001) were higher and the decrease in corneal hysteresis (P=0.0005) and corneal resistance factor (P=0.02) were lower in the SMILE group. CONCLUSION: SMILE and FS-LASIK are comparable in efficacy, safety and predictability for correcting myopia. However, the aberration in the SMILE group is superior to that in the FS-LASIK group, and the loss of biomechanical effects may occur less frequently after SMILE than after FS-LASIK.  相似文献   

13.
AIM: To compare and calculate the 3-year refractive results, higher-order aberrations (HOAs), contrast sensitivity (CS) and dry eye parameters after small incision lenticule extraction (SMILE) and wavefront-guided femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for correction of high myopia and myopic astigmatism. METHODS: In this prospective, non-randomized comparative study, 78 eyes with spherical equivalent (SE) of -8.11±1.09 diopters (D) received a SMILE surgery, and 65 eyes with SE of -8.05±1.12 D received a wavefront-guided FS-LASIK surgery with the VisuMax femtosecond laser (Carl Zeiss Meditec, Jena, Germany) for flap cutting. Visual acuity, manifest refraction, CS, HOAs, ocular surface disease index (OSDI) and tear break-up time (TBUT) were evaluated during a 3-year follow-up. RESULTS: The difference of uncorrected distance visual acuity (UDVA) postoperatively was achieved at 1mo and at 3mo, whereas the difference of the mean UDVA between two groups at 3y were not statistically significant (t=-1.59, P=0.13). The postoperative change of SE was 0.89 D in the FS-LASIK group (t=5.76, P=0.00), and 0.14 D in the SMILE group (t=0.54, P=0.59) from 1mo to 3y after surgery. At 3-year postoperatively, both HOAs and spherical aberrations in the SMILE group were obviously less than those in the FS-LASIK group (P=0.00), but the coma root mean square (RMS) was higher in the SMILE group (0.59±0.26) than in the FS-LASIK group (0.29±0.14, P=0.00). The mesopic CS values between two groups were not statistically significant at 3y postoperatively. Compared with the FS-LASIK group, lower OSDI scores and longer TBUT values were found in the SMILE group at 1mo and 3mo postoperatively. With regard to safety, no eye lost any line of CDVA in both groups at 3y after surgery. CONCLUSION: Both SMILE and wavefront-guided FS-LASIK procedures provide good visual outcomes. Both procedures are effective and safe, but SMILE surgery achieve more stable long-term refractive outcome and better control of early postoperative dry eye as compared to FS-LASIK.  相似文献   

14.
目的:比较飞秒激光小切口角膜基质透镜取出术(SMILE)与改良去瓣机械法准分子激光原位角膜上皮瓣下磨镶术(Epi-LASIK)矫正近视术后1年的临床效果。方法:回顾性病例对照研究。选择2013年3月至2014年8月在南京总医院行SMILE的近视散光患者52例(103眼)作为SMILE组,行改良去瓣Epi-LASIK的近视散光患者43例(86眼)作为Epi-LASIK组。分别在术前,术后1 d、1周、1个月、3个月、6个月、1年测量患者的裸眼视力(UCVA)、最佳矫正视力(BCVA)、残余散光、等效球镜度(SE),并于术后1年测量2组的对比敏感度(CS)、调制传递函数(MTF)、波前像差等。采用重复测量方差分析、t检验和卡方检验对数据进行分析。结果:术后1 d及1周,SMILE组UCVA优于Epi-LASIK组,差异均有统计学意义(t=5.065、5.994,P < 0.001),余时间段2组间UCVA差异均无统计学意义。术后1年,2组间SE在±0.50 D和±1.00 D范围内的眼数百分比差异均无统计学意义,SMILE组柱镜度在±0.50 D范围内的眼数百分比高于Epi-LASIK组,差异有统计学意义( χ 2 =10.734P=0.001)。术后1年,SMILE组在有眩光低空间频率(3、6 cpd)的CS高于Epi-LASIK组,差异均有统计学意义(t=4.106、3.848,P < 0.001);2组在有眩光余空间频率和无眩光所有空间频率的CS差异均无统计学意义。在4 mm瞳孔直径下,2组间全眼像差、低阶像差、高阶像差、球差、慧差、三叶草像差及MTF值在各空间频率上的差异均无统计学意义。在6 mm瞳孔直径下,SMILE组的高阶像差、球差低于Epi-LASIK组,差异均有统计学意义(t=3.881、6.843,P < 0.001),2组间其他像差差异均无统计学意义;SMILE组在低空间频率和高空间频率(5、20、25、30 cpd)的MTF值均高于Epi-LASIK组,差异均有统计学意义(t=3.272,P=0.001;t=2.926,P=0.004;t=3.280,P=0.001;t=3.975,P < 0.001),其他空间频率差异均无统计学意义。结论:SMILE与改良去瓣Epi-LASIK矫正近视均安全、有效、稳定、预测性好,但SMILE对散光的矫正准确性更佳,且在6 mm瞳孔直径下的视觉质量优于改良去瓣Epi-LASIK。  相似文献   

15.
目的 比较波前像差引导的个性化飞秒激光辅助的准分子激光原位角膜磨镶术(FS-LASIK)与角膜地形图引导的个性化FS-LASIK矫正近视术后的视觉质量.设计回顾性比较性病例系列.研究对象北京同仁医院连续接受FS-LASIK的近视眼患者130例(130眼).方法 波前像差引导的FS-LASIK的近视眼患者68例(68眼)...  相似文献   

16.
目的:评价角膜地形图引导的飞秒激光制瓣准分子激光原位角膜磨镶术(FS-LASIK)与常规FS-LASIK 矫正近视及散光术后的视觉质量。方法:前瞻性非随机对照研究。选取2018年9─10月在长沙爱 尔眼科医院屈光中心接受屈光手术的近视及散光患者60例(120眼),按患者选择的手术方式不同分 为角膜地形图引导的FS-LASIK组(TOPO-G组)30例(60眼)和常规FS-LASIK组30例(60眼)。术后 随访3个月,比较2组患者术后1 d、1周、1个月、3个月的裸眼视力(UCVA),术后1周、3个月的 等效球镜度(SE)、柱镜度,以及术后3个月的角膜像差、调制传递函数(MTF)、斯特列尔比(SR)、 Q值及角膜变异指数(ISV)等。采用重复测量方差分析、单因素方差分析及卡方检验对数据进行 分析。结果:TOPO-G组术后1、3个月UCVA均高于FS-LASIK组(t=-2.915,P=0.004;t=-3.377, P=0.001),余时间点2组间UCVA差异无统计学意义。FS-LASIK组术后3个月SE大于TOPO-G组 (t=2.004,P=0.047)。术后3个月,TOPO-G组柱镜度为0的眼数百分比高于FS-LASIK组(76% vs. 51%,χ2 =8.154,P=0.004)。术后3个月,FS-LASIK组总高阶像差、球差和彗差均方根值(RMS)值高 于TOPO-G组,差异均有统计学意义(t=-2.586、-2.133、-2.088,P<0.05)。TOPO-G组在低空间频 率(5 cpd)的MTF值高于FS-LASIK组,差异有统计学意义(t=2.039,P=0.044),余空间频率MTF值 差异无统计学意义。TOPO-G组ISV值低于FS-LASIK组,差异有统计学意义(t=-2.123,P=0.036)。2组 间SR值与Q值差异均无统计学意义。结论:与常规FS-LASIK相比,角膜地形图引导的FS-LASIK术 后视力和角膜表面规则性更好,视觉质量更佳。  相似文献   

17.

目的:探讨飞秒激光制瓣的准分子激光原位角膜磨镶术(FS-LASIK)、角膜地形图引导LASIK(TG-LASIK)和飞秒激光小切口角膜基质透镜取出术(SMILE)对屈光不正患者术后视觉质量及高阶像差的效果。

方法:纳入2019-12/2020-02本院屈光中心收治的296例586眼单纯近视或近视散光患者。在明确手术适应证的前提下,患者自行选择接受FS-LASIK、TG-LASIK、SMILE手术,其中FS-LASIK组95例189眼,TG-LASIK组104例205眼,SMILE组97例192眼。收集患者术前及术后6、12mo时视力、屈光度、角膜地形图、高阶像差及对比敏感度。

结果:术后6、12mo各组患者裸眼视力、最佳矫正视力及球镜度数、柱镜度数、等效球镜度数均优于术前(P<0.05),组间比较均无差异(P>0.05)。术后6、12mo TG-LASIK组角膜表面规则指数、表面非对称指数均显著低于SMILE组、FS-LASIK组(P<0.05); SMILE组、FS-LASIK组组间比较无差异(P>0.05)。术后6、12mo时FS-LASIK组总高阶像差、彗差、球差及术后6mo时三叶草像差高于TG-LASIK组、SMILE组(P<0.05); 术后6、12mo时SMILE组球差显著低于其他两组(P<0.05)。术后6、12mo时TG-LASIK组在无眩光及有眩光时12.0、18.0c/d频率下对比敏感度显著高于SMILE组、FS-LASIK组(P<0.05)。

结论:FS-LASIK、TG-LASIK、SMILE三种手术均可获得较为满意的治疗效果,但TG-LASIK术后像差增加较小,角膜形态更规则,视觉质量更高。  相似文献   


18.

目前,飞秒激光小切口角膜基质透镜取出术(small incision lenticule extraction,SMILE)和飞秒激光辅助的准分子激光原位角膜磨镶术(femtosecond assisted laser in situ keratomileusis,FS-LASIK)是治疗近视和近视散光的主流手术方式。FS-LASIK具有良好的安全性、有效性、稳定性和可预测性,受到近视患者和角膜屈光手术医师的广泛青睐。随着飞秒激光的发展,新型微创角膜屈光手术——SMILE术以其无瓣、微创、小切口、全飞秒等特点,使角膜屈光手术跨入全飞秒时代,成为最主要的屈光手术方式之一。而SMILE与FS-LASIK术在矫正近视和近视散光术后的视力、屈光状态、角膜高阶像差、对比敏感度、干眼、角膜生物力学特性、并发症等方面仍存在一些争议,本文就以上内容对SMILE与FS-LASIK术矫正近视和近视散光术后的优势与不足作一综述。  相似文献   


设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号