首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
2.
This work is intended to investigate the application and accuracy of micro-MOSFET for superficial dose measurement under clinically used MV x-ray beams. Dose response of micro-MOSFET in the build-up region and on surface under MV x-ray beams were measured and compared to Monte Carlo calculations. First, percentage-depth-doses were measured with micro-MOSFET under 6 and 10 MV beams of normal incidence onto a flat solid water phantom. Micro-MOSFET data were compared with the measurements from a parallel plate ionization chamber and Monte Carlo dose calculation in the build-up region. Then, percentage-depth-doses were measured for oblique beams at 0 degrees-80 degrees onto the flat solid water phantom with micro-MOSFET placed at depths of 2 cm, 1 cm, and 2 mm below the surface. Measurements were compared to Monte Carlo calculations under these settings. Finally, measurements were performed with micro-MOSFET embedded in the first 1 mm layer of bolus placed on a flat phantom and a curved phantom of semi-cylindrical shape. Results were compared to superficial dose calculated from Monte Carlo for a 2 mm thin layer that extends from the surface to a depth of 2 mm. Results were (1) Comparison of measurements with MC calculation in the build-up region showed that micro-MOSFET has a water-equivalence thickness (WET) of 0.87 mm for 6 MV beam and 0.99 mm for 10 MV beam from the flat side, and a WET of 0.72 mm for 6 MV beam and 0.76 mm for 10 MV beam from the epoxy side. (2) For normal beam incidences, percentage depth dose agree within 3%-5% among micro-MOSFET measurements, parallel-plate ionization chamber measurements, and MC calculations. (3) For oblique incidence on the flat phantom with micro-MOSFET placed at depths of 2 cm, 1 cm, and 2 mm, measurements were consistent with MC calculations within a typical uncertainty of 3%-5%. (4) For oblique incidence on the flat phantom and a curved-surface phantom, measurements with micro-MOSFET placed at 1.0 mm agrees with the MC calculation within 6%, including uncertainties of micro-MOSFET measurements of 2%-3% (1 standard deviation), MOSFET angular dependence of 3.0%-3.5%, and 1%-2% systematical error due to phantom setup geometry asymmetry. Micro-MOSFET can be used for skin dose measurements in 6 and 10 MV beams with an estimated accuracy of +/- 6%.  相似文献   

3.
This study examines variations of bone and mucosal doses with variable soft tissue and bone thicknesses, mimicking the oral or nasal cavity in skin radiation therapy. Monte Carlo simulations (EGSnrc-based codes) using the clinical kilovoltage (kVp) photon and megavoltage (MeV) electron beams, and the pencil-beam algorithm (Pinnacle(3)?treatment planning system) using the MeV electron beams were performed in dose calculations. Phase-space files for the 105 and 220 kVp beams (Gulmay D3225 x-ray machine), and the 4 and 6?MeV electron beams (Varian 21 EX linear accelerator) with a field size of 5?cm diameter were generated using the BEAMnrc code, and verified using measurements. Inhomogeneous phantoms containing uniform water, bone and air layers were irradiated by the kVp photon and MeV electron beams. Relative depth, bone and mucosal doses were calculated for the uniform water and bone layers which were varied in thickness in the ranges of 0.5-2?cm and 0.2-1?cm. A uniform water layer of bolus with thickness equal to the depth of maximum dose (d(max)) of the electron beams (0.7?cm for 4 MeV and 1.5?cm for 6 MeV) was added on top of the phantom to ensure that the maximum dose was at the phantom surface. From our Monte Carlo results, the 4 and 6 MeV electron beams were found to produce insignificant bone and mucosal dose (<1%), when the uniform water layer at the phantom surface was thicker than 1.5?cm. When considering the 0.5?cm thin uniform water and bone layers, the 4 MeV electron beam deposited less bone and mucosal dose than the 6 MeV beam. Moreover, it was found that the 105 kVp beam produced more than twice the dose to bone than the 220 kVp beam when the uniform water thickness at the phantom surface was small (0.5?cm). However, the difference in bone dose enhancement between the 105 and 220 kVp beams became smaller when the thicknesses of the uniform water and bone layers in the phantom increased. Dose in the second bone layer interfacing with air was found to be higher for the 220 kVp beam than that of the 105 kVp beam, when the bone thickness was 1?cm. In this study, dose deviations of bone and mucosal layers of 18% and 17% were found between our results from Monte Carlo simulation and the pencil-beam algorithm, which overestimated the doses. Relative depth, bone and mucosal doses were studied by varying the beam nature, beam energy and thicknesses of the bone and uniform water using an inhomogeneous phantom to model the oral or nasal cavity. While the dose distribution in the pharynx region is unavailable due to the lack of a commercial treatment planning system commissioned for kVp beam planning in skin radiation therapy, our study provided an essential insight into the radiation staff to justify and estimate bone and mucosal dose.  相似文献   

4.
Given that laser wakefield acceleration (LWFA) has been demonstrated experimentally to accelerate electron beams to energies beyond 25 MeV, it is reasonable to assess the ability of existing LWFA technology to compete with conventional radiofrequency linear accelerators in producing electron and x-ray beams for external-beam radiotherapy. We present calculations of the dose distributions (off-axis dose profiles and central-axis depth dose) and dose rates of x-ray beams that can be produced from electron beams that are generated using state-of-the-art LWFA. Subsets of an LWFA electron energy distribution were propagated through the treatment head elements (presuming an existing design for an x-ray production target and flattening filter) implemented within the EGSnrc Monte Carlo code. Three x-ray energy configurations (6 MV, 10 MV and 18 MV) were studied, and the energy width deltaE of the electron-beam subsets varied from 0.5 MeV to 12.5 MeV. As deltaE increased from 0.5 MeV to 4.5 MeV, we found that the off-axis and central-axis dose profiles for x-rays were minimally affected (to within about 3%), a result slightly different from prior calculations of electron beams broadened by scattering foils. For deltaE of the order of 12 MeV, the effect on the off-axis profile was of the order of 10%, but the central-axis depth dose was affected by less than 2% for depths in excess of about 5 cm beyond d(max). Although increasing deltaE beyond 6.5 MeV increased the dose rate at d(max) by more than 10 times, the absolute dose rates were about 3 orders of magnitude below those observed for LWFA-based electron beams at comparable energies. For a practical LWFA-based x-ray device, the beam current must be increased by about 4-5 orders of magnitude.  相似文献   

5.
Estimation of surface dose is very important for patients undergoing radiation therapy. In this work we investigate the dose at the surface of a water phantom and at a depth of 0.007 cm, the practical reference depth for skin as recommended by ICRP and ICRU, with ultra-thin TLDs and Monte Carlo calculations. The calculations and measurements were carried out for fields ranging from 5 x 5 cm2 to 20 x 20 cm2 for 6 MV, 10 MV and 18 MV photon beams. The variation of the surface dose with angle of incidence and field size was investigated. Also, the exit dose was computed and measured for the same fields and angles of incidence. The dose at the ICRU reference depth was computed. Good agreement (+/-5%) was achieved between measurements and calculations. The surface dose at the entrance increased with the angle of incidence and/or the field size. The exit dose decreased with the angle of incidence but it increased with field size. The dose at the surface of the patient is mostly dependent on the beam energy, modality and beam obliquity rather than the field size and field separation. By correlating TLD measurements with Monte Carlo calculations, we were able to predict the dose at the skin surface with good accuracy. Knowing the dose received at the surface of the patient can lead to prediction of skin reactions helping with the design of new treatment techniques and alternative dose fractionation schemes.  相似文献   

6.
Mobit PN  Sandison GA 《Medical physics》1999,26(11):2503-2507
A detailed Monte Carlo study of the PTW-diamond solid state detector response in megavoltage photon beams (60Co gamma rays to 25 MV x rays) has been performed with the EGS4 Monte Carlo Code. The sensitive volume of the diamond detector is a disk of diameter 4.4 mm and thickness 0.40 mm. The phantom material was water and the irradiation depth was usually 3 cm but additional simulations were performed at six other depths for the 10 and 25 MV x rays. Results show that the PTW-diamond detector response per unit of absorbed dose is constant within 1% for photon beam energies ranging from 60Co gamma rays to 25 MV x rays. Accurate depth dose curves for 10 and 25 MV x-ray beams may be measured with the diamond detector since the response per unit of absorbed dose at different depths in a water phantom is also constant to within 1% for depths ranging from 3 to 25 cm and field sizes ranging from 2.5 cm by 2.5 cm to 10 cm by 10 cm. An examination of the difference between the PTW-diamond detector and the wall-less form of the detector (e.g., TLDs) revealed that there is no significant difference in their response in megavoltage photon beams. This implies that the encapsulation of the diamond dosimeter causes less than a 1.3% change in its response for these megavoltage photon beams. Analysis of the total dose deposited in the sensitive volume of the detector shows that the PTW-diamond detector behaves as an intermediate-sized cavity, not a simple Bragg-Gray cavity, since the dose contribution from photon interactions within the cavity (alpha(c)) to the total cavity dose is 8% for 25 MV x rays and increases to 42% for 60Co gamma rays.  相似文献   

7.
This paper shows the contribution that Monte Carlo methods make in regard to dose distribution calculations in CT based patient models and the role it plays as a gold standard to evaluate other dose calculation algorithms. The EGS4 based BEAM code was used to construct a generic 8 MV accelerator to obtain a series of x-ray field sources. These were used in the EGS4 based DOSXYZ code to generate beam data in a mathematical water phantom to set up a beam model in a commercial treatment planning system (TPS), CADPLAN V.2.7.9. Dose distributions were calculated with the Batho and ETAR inhomogeneity correction algorithms in head/sinus, lung, and prostate patient models for 2 x 2, 5 x 5, and 10 X 10 cm2 open x-ray beams. Corresponding dose distributions were calculated with DOSXYZ that were used as a benchmark. The dose comparisons are expressed in terms of 2D isodose distributions, percentage depth dose data, and dose difference volume histograms (DDVH's). Results indicated that the Batho and ETAR methods contained inaccuracies of 20%-70% in the maxillary sinus region in the head model. Large lung inhomogeneities irradiated with small fields gave rise to absorbed dose deviations of 10%-20%. It is shown for a 10 x 10 cm2 field that DOSXYZ models lateral scatter in lung that is not present in the Batho and ETAR methods. The ETAR and Batho methods are accurate within 3% in a prostate model. We showed how the performance of these inhomogeneity correction methods can be understood in realistic patient models using validated Monte Carlo codes such as BEAM and DOSXYZ.  相似文献   

8.
We have benchmarked photon beam simulations with the EGS4 user code BEAM [Rogers et al., Med. Phys. 22, 503-524 (1995)] by comparing calculated and measured relative ionization distributions in water from the 10 and 20 MV photon beams of the NRC linac. Unlike previous calculations, the incident electron energy is known independently to 1%, the entire extra-focal radiation is simulated, and electron contamination is accounted for. The full Monte Carlo simulation of the linac includes the electron exit window, target, flattening filter, monitor chambers, collimators, as well as the PMMA walls of the water phantom. Dose distributions are calculated using a modified version of the EGS4 user code DOSXYZ which additionally allows scoring of average energy and energy fluence in the phantom. Dose is converted to ionization by accounting for the (L/rho)water(air) variation in the phantom, calculated in an identical geometry for the realistic beams using a new EGS4 user code, SPRXYZ. The variation of (L/rho)water(air) with depth is a 1.25% correction at 10 MV and a 2% correction at 20 MV. At both energies, the calculated and the measured values of ionization on the central axis in the buildup region agree within 1% of maximum ionization relative to the ionization at 10 cm depth. The agreement is well within statistics elsewhere. The electron contamination contributes 0.35(+/- 0.02) to 1.37(+/- 0.03)% of the maximum dose in the buildup region at 10 MV and 0.26(+/- 0.03) to 3.14(+/- 0.07)% of the maximum dose at 20 MV. The penumbrae at 3 depths in each beam (in g/cm2), 1.99 (dmax, 10 MV only), 3.29 (dmax, 20 MV only), 9.79 and 19.79, agree with ionization chamber measurements to better than 1 mm. Possible causes for the discrepancy between calculations and measurements are analyzed and discussed in detail.  相似文献   

9.
The problem of underdosing lesions adjacent to upper respiratory cavities and a proposal to correct it are presented in this work. The EGS4 Monte Carlo code was used to simulate a 6 MV x-ray beam passing through a block of tissues with air cavities 2, 4, and 6 cm wide. The geometry used approximates the tracheal geometry used by previous researchers who investigated the underdosing phenomenon. A uniform longitudinal magnetic field of 0.5 T strength is used to reduce secondary electron outscatter caused by the presence of an air gap, and thus improving the dose at the distal surface of air cavities. We introduce the term "percent dose reduction" (PDR), which is defined as the difference between the dose after the air cavity and the dose at the same depth in soft-tissue phantom normalized to the dose in the tissue phantom, to quantify the reduction in dose after an air gap. We also introduce the term dose improvement ratio (DIR), which is defined as the dose ratio with magnetic field to the dose, at the same point, without magnetic field, to quantify the improvement in dose when the magnetic field is applied. For 2 x 2 x 20 cm3 and 4 x 4 x 20 cm3 air cavities irradiated by 2 x 2 cm2 beams, we found PDRs of 38% and 52%, respectively. This means that for these cavities, there is a 38% and a 52% reduction in dose at the cavity edge compared to the same dose in tissue at the same depth for each cavity. The dose improved by 30% (DIR= 1.3) and 87% (DIR= 1.87), respectively, when applying the magnetic field. The worst effect on dose at the distal side came from larger cavities irradiated with small fields. In these situations, the improvement in dose due to the presence of magnetic field was the largest. This article deals with "ideal" head and neck geometries with a uniform magnetic field. In a paper to follow we will use a CT-based phantom to study the effect in realistic geometries with the presence of a magnetic field from a Helmholtz coil pair.  相似文献   

10.
Ding GX 《Medical physics》2002,29(11):2459-2463
This study investigates a possible cause of reported significant dose discrepancies between Monte Carlo calculations and measurements in the buildup region for high-energy photon beams in large fields. A proposed hypothesis was that the discrepancy was caused by a source of electrons in the accelerator head that was not fully accounted for in the treatment head simulation. In this investigation, a lead foil is added just below the accelerator head in order to study this hypothesis. The lead foil effectively removes charged particles generated inside the accelerator head. The charged particles generated by the lead foil can be accounted for fully because the simple geometry can be simulated accurately. An 18 MV photon beam from a Varian Clinac-2100EX is measured using a WELLHOFER WP700 beam scanner with an IC-10 ionization chamber (cavity radius=3 mm). The BEAM Monte Carlo code is used in the incident beam simulations. Both EGS4/DOSXYZ and EGSnrc/DOSRZnrc are used in the dose calculations in a water phantom. The Monte Carlo calculated depth-dose curve is scaled so that it has the same values at 10 cm depth as the measured curve. It is found that the discrepancies between Monte Carlo calculations and measurements remain significant in the buildup region even after applying necessary corrections to the measured data. The discrepancies have only been modestly decreased with the lead foil in place compared to the 40 x 40 cm2 open field. At a depth of 1 cm, discrepancies of about 5% are still observed in the buildup region for the field with the lead foil. Therefore a new explanation for the unresolved discrepancy remains to be found.  相似文献   

11.
Stereotactic radiosurgery with several static conformal beams shaped by a micro multileaf collimator (microMLC) is used to treat small irregularly shaped brain lesions. Our goal is to perform Monte Carlo calculations of dose distributions for certain treatment plans as a verification tool. A dedicated microMLC component module for the BEAMnrc code was developed as part of this project and was incorporated in a model of the Varian CL2300 linear accelerator 6 MV photon beam. As an initial validation of the code, the leaf geometry was visualized by tracing particles through the component module and recording their position each time a leaf boundary was crossed. The leaf dimensions were measured and the leaf material density and interleaf air gap were chosen to match the simulated leaf leakage profiles with film measurements in a solid water phantom. A comparison between Monte Carlo calculations and measurements (diode, radiographic film) was performed for square and irregularly shaped fields incident on flat and homogeneous water phantoms. Results show that Monte Carlo calculations agree with measured dose distributions to within 2% and/or 1 mm except for field size smaller than 1.2 cm diameter where agreement is within 5% due to uncertainties in measured output factors.  相似文献   

12.
The effect of beam obliquity on the surface relative dose profiles for the tangential photon beams was studied. The 6 and 15 MV photon beams with 4 x 4 and 10 x 10 cm2 field sizes produced by a Varian 21 EX linear accelerator were used. Phase-space models of the photon beams were created using Monte Carlo simulations based on the EGSnrc code, and were verified using film measurements. The relative dose profiles in the phantom skin, at 2 mm depth from the surface of the half-phantom geometry, or HPG, were calculated for increasing gantry angles from 270 to 280 deg clockwise. Relative dose profiles of a full phantom enclosing the whole tangential beam (full phantom geometry, or FPG) were also calculated using Monte Carlo simulation as a control for comparison. The results showed that, although the relative dose profiles in the phantom skin did not change significantly with an oblique beam using a FPG, the surface relative depth dose was increased for the HPG. In the HPG, with 6 MV photon beams and field size = 10 x 10 cm2, when the beam angle, starting from 270 deg, was increased from 1 to 3 deg, the relative depth doses in the phantom skin were increased from 68% to 79% at 10 cm depth. This increase in dose was slightly larger than the dose from 15 MV photon beams with the same field size and beam angles, where the relative depth doses in phantom skin were increased from 81% to 87% at 10 cm depth. A parameter called the percent depth dose (PDD) ratio, defined as the relative depth dose from the HPG to the relative depth dose from the FPG at a given depth along the phantom skin, was used to evaluate the effect of the phantom-air interface. It is found that the PDD ratio increased significantly when the beam angle was changed from zero to 1-3 degrees. Moreover, the PDD ratio, for a given field size, experienced a greater increase for 6 MV than for 15 MV. For the same photon beam energy, the PDD ratio increased more with a 4 x 4 cm2 field compared to 10 x 10 cm2. The results in this study will be useful for physicists and dosimetrists to predict the surface relative dose variations when using clinical tangential-like photon beams in radiation therapy.  相似文献   

13.
A hybrid phantom-embedded extrapolation chamber (PEEC) made of Solid Water and bone-equivalent material was used for determining absorbed dose in a bone-equivalent phantom irradiated with clinical radiation beams (cobalt-60 gamma rays; 6 and 18 MV x rays; and 9 and 15 MeV electrons). The dose was determined with the Spencer-Attix cavity theory, using ionization gradient measurements and an indirect determination of the chamber air-mass through measurements of chamber capacitance. The collected charge was corrected for ionic recombination and diffusion in the chamber air volume following the standard two-voltage technique. Due to the hybrid chamber design, correction factors accounting for scatter deficit and electrode composition were determined and applied in the dose equation to obtain absorbed dose in bone for the equivalent homogeneous bone phantom. Correction factors for graphite electrodes were calculated with Monte Carlo techniques and the calculated results were verified through relative air cavity dose measurements for three different polarizing electrode materials: graphite, steel, and brass in conjunction with a graphite collecting electrode. Scatter deficit, due mainly to loss of lateral scatter in the hybrid chamber, reduces the dose to the air cavity in the hybrid PEEC in comparison with full bone PEEC by 0.7% to approximately 2% depending on beam quality and energy. In megavoltage photon and electron beams, graphite electrodes do not affect the dose measurement in the Solid Water PEEC but decrease the cavity dose by up to 5% in the bone-equivalent PEEC even for very thin graphite electrodes (<0.0025 cm). In conjunction with appropriate correction factors determined with Monte Carlo techniques, the uncalibrated hybrid PEEC can be used for measuring absorbed dose in bone material to within 2% for high-energy photon and electron beams.  相似文献   

14.
The energy dependence of alanine/EPR dosimetry, in terms of absorbed dose-to-water for clinical 6, 10, 25 MV x-rays and 60Co gamma-rays was investigated by measurements and Monte Carlo (MC) calculations. The dose rates were traceable to the NRC primary standard for absorbed dose, a sealed water calorimetry. The electron paramagnetic resonance (EPR) spectra of irradiated pellets were measured using a Bruker EMX 081 EPR spectrometer. The DOSRZnrc Monte Carlo code of the EGSnrc system was used to simulate the experimental conditions with BEAM code calculated input spectra of x-rays and gamma-rays. Within the experimental uncertainty of 0.5%, the alanine EPR response to absorbed dose-to-water for x-rays was not dependent on beam quality from 6 MV to 25 MV, but on average, it was about 0.6% lower than its response to 60Co gamma-rays. Combining experimental data with Monte Carlo calculations, it is found that the alanine/EPR response per unit absorbed dose-to-alanine is the same for clinical x-rays and 60Co gamma-rays within the uncertainty of 0.6%. Monte Carlo simulations showed that neither the presence of PMMA holder nor varying the dosimeter thickness between 1 mm and 5 mm has significant effect of the energy dependence of alanine/EPR dosimetry within the calculation uncertainty of 0.3%.  相似文献   

15.
The perturbation correction factor gamma(p) is defined as the deviation of the absorbed dose in the medium from that predicted by the Spencer-Attix extension of the Bragg-Gray cavity theory where the medium occupies exactly the same volume as the solid state cavity and the electron fluence energy spectrum in the cavity is identical in shape, but not necessarily in magnitude, to that in the medium. The value of gamma(p) has been examined for TL detectors irradiated in megavoltage electron beams (5-20 MeV) using the EGS4 Monte Carlo code. LiF and CaF2 solid state detectors simulated were standard size discs of thickness 1 mm and diameter 3.61 mm irradiated in a water phantom with their centres at d(max) or close to it. Values of gamma(p) for LiF ranged from 0.998 +/- 0.005 to 0.994 +/- 0.005 for electron beams with initial energies of 5 and 20 MeV respectively. For CaF2 the corresponding values were 0.956 +/- 0.006 to 0.989 +/- 0.006 for the same size cavities irradiated at the same depth. EGS4 Monte Carlo simulations demonstrate that the total electron fluence (primary electrons and delta-rays) in these solid state detector materials is significantly different from that in water for the same incident electron energy and depth of irradiation. Thus the Spencer-Attix assumption that the electron fluence energy spectrum in the cavity is identical in shape to that in the medium is violated. Differences in the total electron fluence give rise to electron fluence perturbation correction factors which were up to 5% less than unity for CaF2, indicating a strong violation in this case, but were generally less than 1% for LiF. It is the density of the cavity which perturbs the electron fluence, but it is actually the atomic number differences between the medium and cavity that are responsible for the large electron fluence perturbation correction factors for detectors irradiated close to d(max) because the atomic number affects the change in stopping power with energy. When correction is made for the difference between the electron fluence spectrum in the uniform water phantom and the solid state cavity, the Spencer-Attix cavity equation predicts the dose to water within 0.3% in both clinical and monoenergetic electron beams. Harder's formulation for computing the average mass collision stopping power of water to calcium fluoride, surprisingly, requires perturbation correction factors that are closer to unity than those determined using the Spencer-Attix integrals at depths close to d(max).  相似文献   

16.
A comprehensive set of measurements and calculations has been conducted to investigate the accuracy of the Dose Planning Method (DPM) Monte Carlo code for dose calculations from 10 and 50 MeV scanned electron beams produced from a racetrack microtron. Central axis depth dose measurements and a series of profile scans at various depths were acquired in a water phantom using a Scanditronix type RK ion chamber. Source spatial distributions for the Monte Carlo calculations were reconstructed from in-air ion chamber measurements carried out across the two-dimensional beam profile at 100 cm downstream from the source. The in-air spatial distributions were found to have full width at half maximum of 4.7 and 1.3 cm, at 100 cm from the source, for the 10 and 50 MeV beams, respectively. Energy spectra for the 10 and 50 MeV beams were determined by simulating the components of the microtron treatment head using the code MCNP4B. DPM calculations are on average within +/- 2% agreement with measurement for all depth dose and profile comparisons conducted in this study. The accuracy of the DPM code illustrated in this work suggests that DPM may be used as a valuable tool for electron beam dose calculations.  相似文献   

17.
The response of LiF:Mg,Ti thermoluminescent dosimeters (TLDs) as a function of photon energy was determined using irradiations with moderately filtered x-ray beams in the energy range of 20-250 kVp relative to the response to irradiations with 60Co photons. To determine if the relative light output from LiF:Mg,Ti TLDs per unit air kerma as a function of photon energy can be predicted using calculations such as Monte Carlo (MC) simulations, measurements from the x-ray beam irradiations were compared with MC calculated results, similar to the methodology used by Davis et al. [Radiat. Prot. Dosim. 106, 33-43 (2003)]. TLDs were irradiated in photon beams with well-known air kerma rates using the National Institute of Standards and Technology traceable M-series x-ray beams in the range of 20-250 kVp. For each x-ray beam, several sets of TLDs were irradiated for times corresponding to different air kerma levels to take into account any dose nonlinearity. TLD light output was then compared to that from several sets of TLDs irradiated at similar corresponding air kerma levels using a 60Co irradiator. The MC code MCNP5 was used to account for photon scatter and attenuation in the holder and TLDs and was used to calculate the predicted relative TLD light output per unit air kerma for irradiations with each of the experimentally used photon beams. The measured relative TLD response as a function of photon energy differed by up to 13% from the MC calculations. We conclude that MC calculations do not accurately predict the relative response of TLDs as a function of photon energy, consistent with the conclusions of Davis et al. [Radiat. Prot. Dosim. 106, 33-43 (2003)]. This is likely due to complications in the solid state physics of the thermoluminescence process that are not incorporated into the simulation.  相似文献   

18.
INTRODUCTION AND PURPOSE: Conventional x-ray films and radiochromic films have inherent challenges for high precision radiotherapy dosimetry. Here we have investigated basic characteristics of optically stimulated luminescence (OSL) of irradiated films containing carbon-doped aluminum oxide (Al2O3:C) for dosimetry in therapeutic photon and electron beams. MATERIALS AND METHODS: The OSL films consist of a polystyrene sheet, with a top layer of a mixture of single crystals of Al2O3:C, ground into a powder, and a polyester base. The total thickness of the films is 0.3 mm. Measurements have been performed in a water equivalent phantom, using 4, 6, 10, and 18 MV photon beams, and 6-22 MeV electron beams. The studies include assessment of the film response (acquired OSL signal/delivered dose) on delivered dose (linearity), dose rate (1-6 Gy/min), beam quality, field size and depth (6 MV, ranges 4 x 4-30 x 30 cm2, dmax-35 cm). Doses have been derived from ionization chamber measurements. OSL films have also been compared with conventional x-ray and GafChromic films for dosimetry outside the high dose area, with a high proportion of low dose scattered photons. In total, 787 OSL films have been irradiated. RESULTS: Overall, the OSL response for electron beams was 3.6% lower than for photon beams. Differences between the various electron beam energies were not significant. The 6 and 18 MV photon beams differed in response by 4%. No response dependencies on dose rate were observed. For the 6 MV beam, the field size and depth dependencies of the OSL response were within +/-2.5%. The observed inter-film response variation for films irradiated with the same dose varied from 1% to 3.2% (1 SD), depending on the measurement day. At a depth of 20 cm, 5 cm outside the 20 x 20 cm2 6 and 18 MV beams, an over response of 17% was observed. In contrast to GafChromic and conventional x-ray films, the response of the Al2O3:C films is linear in the clinically relevant dose range 0-200 cGy. CONCLUSIONS: Measurement of the OSL signal of irradiated films containing Al2O3:C is a promising technique for film dosimetry in radiotherapy with no or small response variations with dose rate, beam quality, field size and depth, and a linear response from 0 to 200 cGy.  相似文献   

19.
It has been shown in several studies that the build-up in photon beams behind air cavities (such as in the head and neck) increases with energy. In this study this effect is investigated over a broad range of energies that have been used for treating head and neck tumours. The study addresses the question of whether an energy lower than 6 MV is desirable and is based on measurements and Monte Carlo (MC) simulations. In a PMMA phantom containing an air cavity (3 x 16 x 3 cm3 at 3 cm depth) an ionization chamber (Capintec PS-033) was used to measure the dose build-up behind the cavity for 4, 6 and 8 MV beam qualities for different field sizes (from 3 x 6 cm2 to 8 x 8 cm2). MC simulations were made using the EGSnrc code for the same geometry and energies as well as for Co-60. Measurements and MC simulations agree well when the fixed-separation plane-parallel chamber measurements have been corrected for the expected over-response in the build-up region. This work demonstrates that the build-up effect of 6 MV is 'closer' to the build-up effect of 8 MV than to that of 4 MV. This suggests that if the build-up effect is of concern when the target volume is in the vicinity of air cavities, 4 MV should be preferred over both 6 MV and 8 MV. This work also shows that the build-up effect for Co-60 is significantly smaller than that of 4 MV. Moreover, the build-up effect increases as the field size decreases. With the increasing use of IMRT (and radiosurgery), small fields are used more frequently making these issues even more relevant. This should be taken into consideration when choosing the accelerator energies for a radiotherapy department.  相似文献   

20.
This study investigates the feasibility of using Monte Carlo methods to assist the commissioning of photon beam output factors from a medical accelerator. The Monte Carlo code, BEAMnrc, was used to model 6 MV and 18 MV photon beams from a Varian linear accelerator. When excellent agreements were obtained between the Monte Carlo simulated and measured dose distributions in a water phantom, the entire geometry including the accelerator head and the water phantom was simulated to calculate the relative output factors. Simulated output factors were compared with measured data, which consist of a typical commission dataset for the output factors. The measurements were done using an ionization chamber in a water phantom at a depth of 10 cm with a source-detector distance of 100 cm. Square fields and rectangular fields with widths and lengths ranging from 4 cm to 40 cm were studied. The result shows a very good agreement (< 1.5%) between the Monte Carlo calculated and the measured relative output factors for a typical commissioning dataset. The Monte Carlo calculated backscatter factors to the beam monitor chamber agree well with measured data in the literature. Monte Carlo simulations have also been shown to be able to accurately predict the collimator exchange effect and its component for rectangular fields. The information obtained is also useful to develop an algorithm for accurate beam modelling. This investigation indicates that Monte Carlo methods can be used to assist commissioning of output factors for photon beams.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号