首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We describe a case of hyperacute subarachnoid and intraventricular hemorrhage from a ruptured aneurysm, which occurred while the patient was undergoing MR imaging. Compared with CSF, the blood in the subarachnoid space had slightly lower signal intensity on T2*-weighted gradient-echo images and increased signal intensity on T2-weighted spin-echo images. This finding differs from the generally accepted MR appearance of intracranial hemorrhage and should be recognized to ensure proper patient care.  相似文献   

2.
The purpose of this study was to prospectively compare high-spatial-resolution accelerated three-dimensional (3D) T2*-weighted gradient-recalled-echo (GRE) magnetic resonance (MR) images with conventional two-dimensional (2D) T2*-weighted GRE MR images for the depiction of cerebral microbleeds. After obtaining institutional review board approval and informed consent, 200 elderly participants (age range, 69.7-96.7 years; 108 [54%] women) were imaged at 1.5 T by using both sequences. Presence, number, and location of microbleeds were recorded for both sequences, and differences were tested by using McNemar and signed rank tests. Cerebral microbleeds were detected in significantly more participants on 3D T2*-weighted GRE images (35.5%) than on 2D T2*-weighted GRE images (21.0%; P < .001). Furthermore, in persons with microbleeds visualized on both image sets, significantly more microbleeds (P < .001) were seen on 3D images than on 2D images. For both sequences, the proportion of participants with a microbleed in a lobar (cortical gray and subcortical white matter), deep, or infratentorial location was similar. In conclusion, accelerated 3D T2*-weighted GRE images depict more microbleeds than do conventional 2D T2*-weighted GRE images.  相似文献   

3.
RATIONALE AND OBJECTIVES: The objective of this study was to evaluate a 2-dimensional spoiled gradient echo (GRE) imaging approach using a very short in-phase TE for routine T1-weighted imaging of the brain at 3 T. MATERIALS AND METHODS: Patient examinations were compared from a 3 T magnetic resonance (MR) unit located immediately adjacent to a similarly equipped 1.5 T unit. Pre- and postcontrast T1-weighted images were evaluated and compared at 1.5 versus 3 T with a 2-dimensional (2-D) spin echo sequence used at 1.5 T and a 2-D GRE sequence at 3 T. The 2 MR systems used are from the same vendor, use similar 8-channel coils, and use identical gradients. The T1-weighted GRE sequence, used at 3 T, relies on a short TE (2.4 ms) to limit flow-related and susceptibility artifacts. Region-of-interest analysis was performed on 16 different sagittal patient examinations at both field strengths (32 total) and similarly on 10 different pre- and postcontrast axial examinations (40 total). Four blinded neuroradiologists also evaluated these studies. RESULTS: Using an off-midline sagittal slice depicting the caudate nucleus (signal-to-noise ratio [SNR] 163 +/- 28 vs. 70 +/- 7, 3 T vs. 1.5 T) and corona radiata (SNR 214 +/- 35 vs. 82 +/- 10), 3 T markedly outperformed 1.5 T in both SNR and contrast-to-noise ratio (CNR) (51 +/- 14 vs. 12 +/- 5). On axial imaging, despite a reduction in slice thickness (5 to 3 mm) and scan time (5 to 1 minute), there was no significant difference pre- or postcontrast in SNR and CNR comparing 3 and 1.5 T. On blinded film review, 3 T performed slightly better on sagittal scans than 1.5 T in regard to motion artifacts (reduced), gray-white matter differentiation, and overall image quality. On axial scans, 3 T performed markedly better in all 3 categories both pre- and postcontrast. In regard to overall image quality, 3 T was preferred 9:2 precontrast and 4:1 postcontrast. CONCLUSIONS: High-quality, thin-section (3-mm) T1-weighted imaging can be readily performed at 3 T using a short TE 2-D GRE technique. This approach offers superior SNR and CNR with reduced motion artifacts and scan time as compared with imaging at 1.5 T and is advocated for routine brain imaging at 3 T. It is robust (used in over 1500 patients to date) and does not experience significant specific absorption ratio limitations, poor tissue contrast, or accentuated motion artifacts like encountered with spin echo T1-weighted imaging at 3 T.  相似文献   

4.
BACKGROUND AND PURPOSE: Intratumoral hemorrhage occurs frequently in pituitary macroadenoma and manifests as pituitary apoplexy and recent or old silent hemorrhage. T2*-weighted gradient-echo (GE) MR imaging is the most sensitive sequence for the detection of acute and old intracranial hemorrhage. T2*-weighted GE MR imaging was used to investigate intratumoral hemorrhage in pituitary macroadenomas. MATERIALS AND METHODS: Twenty-five consecutive patients who underwent total or subtotal resection of pituitary macroadenoma with heights from 17 to 53 mm, including 1 patient with classic pituitary apoplexy, underwent MR imaging before surgery, including T2*-weighted GE MR imaging. For histologic assessment of the hemorrhage in whole surgical specimens, we used hematoxylin-eosin staining. RESULTS: T2*-weighted GE MR imaging detected various types of dark lesions, such as "rim," "mass," "spot," and "diffuse" and combinations, indicating clinical and subclinical intratumoral hemorrhage in 12 of the 25 patients. The presence of intratumoral dark lesions on T2*-weighted GE MR imaging correlated significantly with the hemorrhagic findings on T1- and T2-weighted MR imaging (P < .02 and <.01, respectively), and the surgical and histologic hemorrhagic findings (P < .001 and <.001, respectively). CONCLUSION: T2*-weighted GE MR imaging could detect intratumoral hemorrhage in pituitary adenomas as various dark appearances. Therefore, this technique might be useful for the assessment of recent and old intratumoral hemorrhagic events in patients with pituitary macroadenomas.  相似文献   

5.
PURPOSE: To evaluate and compare the diagnostic accuracy of appropriate magnetic resonance (MR) sequences in the detection of cartilage lesions at 1.5T and 3.0T. MATERIAL AND METHODS: Twelve chondral defects of varying depths, widths, and locations were created in the retropatellar hyaline cartilage in six sheep cadaver limbs. Axial images employing three fat-suppressed imaging sequences--(1) a T2-weighted fast spin-echo (FSE) sequence, (2) a two-dimensional (2D) and (3) three-dimensional (3D) gradient-echo (GE) sequence at 1.5T and 3.0T using an extremity quadrature coil--were evaluated by three experienced radiologists. Statistical analysis of the results consisted of receiver operating characteristics (ROC) and significant testing using the bivariate chi-square test. In addition, signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) were evaluated with significance testing using the Wilcoxon test. RESULTS: The 3D GE sequence compared favorably with other sequences at 3.0T and 1.5T (Az=0.88 at 3.0T and Az=0.85 at 1.5T) missing only one small grade 2 lesion. 2D GE imaging was inferior to 3D imaging at both field strengths (P<0.05) in general. However, compared to 1.5T, lesion detectability was improved at the higher magnetic field of 3.0T (Az=0.81 and 0.73 at 3.0T and 1.5T, respectively). FSE images showed significantly inferior sensitivity and less anatomical detail compared to the GE sequences at both field strengths (Az=0.64 and 0.72 at 3.0T and 1.5T, respectively; P<0.05). However, compared to 1.5T, lesion detectability SNR and CNR values were superior in all sequences tested at 3.0T. CONCLUSION: MRI at 3.0T improves SNR and CNR significantly in the most common sequences for cartilage MRI, resulting in an improvement in chondral lesion detection. GE imaging therefore allows resolution to be increased in an acceptable time manner for patient comfort, and the 3D GE fat-suppressed sequence at 3.0T appears to be best suited for cartilage imaging in a clinical setting.  相似文献   

6.
To compare an isotropic three-dimensional (3D) high-resolution T2-weighted (w) MR sequence and its reformations with conventional sequences for imaging of the cervical spine. Fifteen volunteers were examined at 1.5 T using sagittal and axial 3D T2-w, sagittal and axial 2D T2w, and axial 2D T2*w MR sequences. Axial reformations of the sagittal 3D dataset were generated (3D MPR T2w). Signal-to-noise and image homogeneity were evaluated in a phantom and in vivo. Visibility of ten anatomical structures of the cervical spine was evaluated. Artifacts were assessed. For statistical analysis, Cohen’s kappa, Wilcoxon matched pairs, and t-testing were utilized. There were no significant differences in homogeneity between the sequences. Sagittal 3D T2w enabled better delineation of nerve roots, neural foramina, and intraforaminal structures compared to sagittal 2D T2w. Axial 3D T2w and axial 3D MPR T2w resulted in superior visibility of most anatomical structures compared to axial 2D T2w and comparable results to 2D T2*w concerning the spinal cord, nerve roots, intraforaminal structures, and fat. Artifacts were most pronounced in axial 2D T2w and axial 3D T2w. Acquisition of a 3D T2w data set is feasible in the cervical spine with superior delineation of anatomical structures compared to 2D sequences.  相似文献   

7.
We report preliminary results applying fluid-attenuated inversion-recovery (FLAIR) sequences to three patients with acute subarachnoid hemorrhage. Acute subarachnoid hemorrhage could be clearly demonstrated as areas of high signal intensity on FLAIR sequences in all patients. These preliminary results suggest that with FLAIR sequences one could reliably diagnose acute subarachnoid hemorrhage.  相似文献   

8.
Li T  Mirowitz SA 《Clinical imaging》2003,27(2):124-128
Echo planar imaging (EPI) is an ultra-fast magnetic resonance (MR) imaging method that provides strong T2-weighted contrast, which is important for the detection and characterization of various abdominal abnormalities. However, EPI may be associated with significant artifacts. The prominence of these artifacts, as well as overall image quality, is dramatically impacted by selection of imaging parameters. The purpose of this study is to demonstrate the effects of controlled alterations in operator-defined imaging parameters on image quality in breath-hold abdominal T2-weighted EPI. An understanding of these effects facilitates optimizing parameter selection for acquisition of abdominal EPI images.  相似文献   

9.
PURPOSE: To evaluate the diagnostic value of an imaging protocol that combines dynamic contrast-enhanced T1-weighted magnetic resonance (MR) imaging and T2*-weighted first-pass perfusion imaging in patients with breast tumors and to determine if T2*-weighted imaging can provide additional diagnostic information to that obtained with T1-weighted imaging. MATERIALS AND METHODS: One hundred thirty patients with breast tumors underwent MR imaging with dynamic contrast-enhanced T1-weighted imaging of the entire breast, which was followed immediately with single-section, T2*-weighted imaging of the tumor. RESULTS: With T2*-weighted perfusion imaging, 57 of 72 carcinomas but only four of 58 benign lesions had a signal intensity loss of 20% or more during the first pass, for a sensitivity of 79% and a specificity of 93%. With dynamic contrast-enhanced T1-weighted imaging, 64 carcinomas and 19 benign lesions showed a signal intensity increase of 90% or more in the first image obtained after the administration of contrast material, for a sensitivity of 89% and a specificity of 67%. CONCLUSION: T2*-weighted first-pass perfusion imaging can help differentiate between benign and malignant breast lesions with a high level of specificity. The combination of T1-weighted and T2*-weighted imaging is feasible in a single patient examination and may improve breast MR imaging.  相似文献   

10.
Kim KW  Park MS  Yu JS  Chung JP  Ryu YH  Lee SI  Lee KS  Yoon SW  Lee KH 《Radiology》2003,227(2):580-584
Twelve patients with symptoms of acute cholecystitis underwent heavily T2-weighted and mangafodipir trisodium-enhanced T1-weighted magnetic resonance (MR) cholangiography and cholescintigraphy before they underwent cholecystectomy. On T2-weighted MR cholangiographic images, morphologic evidence of outflow obstruction of the gallbladder was definitive in seven patients, equivocal in one, and absent in four. In all 12 patients, biliary dynamics depicted at manganese-enhanced T1-weighted MR cholangiography agreed completely with those depicted at hepatobiliary scintigraphy. T2-weighted MR cholangiography combined with manganese-enhanced T1-weighted MR cholangiography provides not only morphologic information but also functional information about the biliary system.  相似文献   

11.
We evaluated the newly developed whole-brain, isotropic, 3-dimensional turbo spin-echo imaging with variable flip angle echo train (SPACE) for contrast-enhanced T(1)-weighted imaging in detecting brain metastases at 3 tesla (T). Twenty-two patients with suspected brain metastases underwent postcontrast study with SPACE, magnetization-prepared rapid gradient-echo (MP-RAGE), and 2-dimensional T(1)-weighted spin echo (2D-SE) imaging at 3T. We quantitatively compared SPACE, MP-RAGE, and 2D-SE images by using signal-to-noise ratios (SNRs) for gray matter (GM) and white matter (WM) and contrast-to-noise ratios (CNRs) for GM-to-WM, lesion-to-GM, and lesion-to-WM. Two blinded radiologists evaluated the detection of brain metastases by segment-by-segment analysis and continuously-distributed test. The CNR between GM and WM was significantly higher on MP-RAGE images than on SPACE images (P<0.01). The CNRs for lesion-to-GM and lesion-to-WM were significantly higher on SPACE images than on MP-RAGE images (P<0.01). There was no significant difference in each sequence in detection of brain metastases by segment-by-segment analysis and the continuously-distributed test. However, in some cases, the lesions were easier to detect in SPACE images than in other sequences, and also the vascular signals, which sometimes mimic lesions in MP-RAGE and 2D-SE images, were suppressed in SPACE images. In detection of brain metastases at 3T magnetic resonance (MR) imaging, SPACE imaging may provide an effective, alternative approach to MP-RAGE imaging for 3D T(1)-weighted imaging.  相似文献   

12.
The authors assessed regional cerebral blood flow dynamics with magnetic resonance (MR) imaging enhanced with gadolinium diethylenetriaminepentaacetic acid (DTPA). After bolus administration of Gd-DTPA, rapid T2*-weighted gradient-echo images were acquired. Image acquisition time ranged from 2 to 3 seconds. The signal intensity (SI) of brain tissue and blood vessels markedly decreased during the first pass of contrast agent through the brain due to the local field inhomogeneity caused by the concentrated paramagnetic contrast agent. The method was used in 18 subjects with no cerebrovascular disease and 32 patients with stroke, vascular stenosis, arteriovenous malformation, and cerebral neoplasm. Comparison with intracranial angiography was performed in three patients and with single-photon emission computed tomography of blood flow in four. The change in T2* relaxation rate was approximately linearly related to the dose of contrast agent. The SI change increased as the echo time was lengthened. Regions in cerebral infarcts, metastases, and arteriovenous malformations showed different enhancement patterns than those of edema around a lesion and of normal brain tissue. Abnormal circulation times in patients with vascular stenoses were demonstrated. The method provides information about cerebral blood flow dynamics not available from conventional MR imaging and MR angiography.  相似文献   

13.
IntroductionTo investigate the impact of parameter optimisation for novel three-dimensional 3D sequences at 1.5T and 3T on resultant image quality.MethodsFollowing institutional review board approval and acquisition of informed consent, MR phantom and knee joint imaging on healthy volunteers (n = 16) was performed with 1.5 and 3T MRI scanners, respectively incorporating 8- and 15-channel phased array knee radiofrequency coils. The MR phantom and healthy volunteers were prospectively scanned over a six-week period. Acquired sequences included standard two-dimensional (2D) turbo spin echo (TSE) and novel three-dimensional (3D) TSE PDW (SPACE) both with and without fat-suppression, and T21W gradient echo (TrueFISP) sequences. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured for knee anatomical structures. Two musculoskeletal radiologists evaluated anatomical structure visualisation and image quality. Quantitative and qualitative findings were investigated for differences using Friedman tests. Inter- and intra-observer agreements were determined with κ statistics.ResultsPhantom and healthy volunteer images revealed higher SNR for sequences acquired at 3T (p-value <0.05). Generally, the qualitative findings ranked images acquired at 3T higher than corresponding images acquired at 1.5T (p < 0.05). 3D image data sets demonstrated less sensitivity to partial volume averaging artefact (PVA) compared to 2D sequences. Inter- and intra-observer agreements for evaluation across all sequences ranged from 0.61 to 0.79 and 0.71 to 0.92, respectively.ConclusionBoth 2D and 3D images demonstrated higher image quality at 3T than at 1.5T. Optimised 3D sequences performed better than the standard 2D PDW TSE sequence for contrast resolution between cartilage and joint fluid, with reduced PVA artefact.Implications for practiceWith rapid advances in MRI scanner technology, including hardware and software, the optimisation of 3D MR pulse sequences to reduce scan time while maintaining image quality, will improve diagnostic accuracy and patient management in musculoskeletal MRI.  相似文献   

14.
Glial neoplasms: dynamic contrast-enhanced T2*-weighted MR imaging.   总被引:82,自引:0,他引:82  
PURPOSE: To evaluate the role of T2*-weighted echo-planar perfusion imaging by using a first-pass gadopentetate dimeglumine technique to determine the association of magnetic resonance (MR) imaging-derived cerebral blood volume (CBV) maps with histopathologic grading of astrocytomas and to improve the accuracy of targeting of stereotactic biopsy. MATERIALS AND METHODS: MR imaging was performed in 29 patients by using a first-pass gadopentetate dimeglumine T2*-weighted echo-planar perfusion sequence followed by conventional imaging. The perfusion data were processed to obtain a color map of relative regional CBV. This information formed the basis for targeting the stereotactic biopsy. Relative CBV values were computed with a nondiffusible tracer model. The relative CBV of lesions was expressed as a percentage of the relative CBV of normal white matter. The maximum relative CBV of each lesion was correlated with the histopathologic grading of astrocytomas obtained from samples from stereotactic biopsy or volumetric resection. RESULTS: The maximum relative CBV in high-grade astrocytomas (n = 26) varied from 1.73 to 13.7, with a mean of 5.07 +/- 2.79 (+/- SD), and in the low-grade cohort (n = 3) varied from 0.92 to 2.19, with a mean of 1.44 +/- 0.68. This difference in relative CBV was statistically significant (P < .001; Student t test). CONCLUSION: Echo-planar perfusion imaging is useful in the preoperative assessment of tumor grade and in providing diagnostic information not available with conventional MR imaging. The areas of perfusion abnormality are invaluable in the precise targeting of the stereotactic biopsy.  相似文献   

15.
Dynamic contrast-enhanced T2*-weighted MR imaging of gliomatosis cerebri   总被引:12,自引:0,他引:12  
BACKGROUND AND PURPOSE: MR imaging characteristics of gliomatosis cerebri reiterate the diffuse nature of this tumor but are nonspecific and thus may pose a diagnostic challenge. Because perfusion MR imaging can provide a physiologic map of the microcirculation, we compared the measured relative cerebral blood volume (rCBV) at perfusion imaging with histopathologic findings in gliomatosis cerebri. MR spectroscopic findings were also reviewed. METHODS: Retrospective analysis was performed of conventional and perfusion MR images from seven patients with proved gliomatosis cerebri. The conventional MR images were evaluated for the presence or absence of contrast enhancement, necrosis, and extent of T2-weighted signal intensity abnormality. Dynamic contrast-enhanced T2*-weighted gradient-echo echo-planar images were acquired during the first pass of a bolus injection of gadopentetate dimeglumine. The rCBV was calculated by using nondiffusible tracer kinetics and expressed relative to normal-appearing white matter. Pathologic findings were reviewed in all patients and compared with the MR perfusion data. Multivoxel 2D chemical shift imaging proton MR spectroscopic data were available for three patients and single-voxel data for one patient. RESULTS: Conventional MR images showed diffuse abnormality in all cases and absence of contrast enhancement in all but one case. Average rCBV range was 0.75-1.26 (mean, 1.02 +/- 0.42 [SD]). MR spectroscopic data revealed spectra consistent with presence of tumoral disease. Histopathologic review showed absence of vascular hyperplasia in all specimens. CONCLUSION: The low MR rCBV measurements of gliomatosis cerebri are in concordance with the lack of vascular hyperplasia found at histopathologic examination; thus, perfusion MR imaging provides useful adjunctive information that is not available from conventional MR imaging techniques.  相似文献   

16.
The T2* relaxation time of blood varies with its oxygen saturation. To evaluate the feasibility of imaging intravascular blood oxygenation in humans using a conventional 1.5T MR system, we have implemented a method to measure T2* of blood despite the presence of pulsatile flow. The method was tested in a) stationary and flow phantoms, b) blood samples at different levels of oxygen saturation, and c) a human hypoxia model. Our results demonstrate the ability of cardiac-triggered, flow compensated gradient echo imaging to obtain reproducible T2* measurements of flowing blood in vivo.  相似文献   

17.
PURPOSE: To compare breath-hold fast-recovery fast spin echo (FR-FSE) and non-breath-hold fast spin echo (FSE) T2-weighted sequences for hepatic lesion conspicuity and image quality at MR imaging. MATERIALS AND METHODS: Fifty-nine patients with known or suspected liver lesions underwent hepatic MR imaging by using a breath-hold FR-FSE T2-weighted sequence with and without fat suppression and a non-breath-hold FSE T2-weighted sequence with and without fat suppression. Quantitative analysis was made with measurements of the signal intensity of the liver, spleen, background noise, and up to three liver lesions, as well as calculations of the liver signal-to-noise ratio (SNR) and the liver-to-lesion contrast-to-noise ratio (CNR) for each sequence. Qualitative analysis was made for image quality and the number of lesions identified. Statistical analysis was performed by using a single-tailed paired Student's t test with a 95% confidence interval. RESULTS: SNR and CNR were significantly higher (P<.05) for FSE with fat suppression than for FR-FSE with fat suppression. No statistically significant difference was seen in terms of SNR and CNR between non-fat-suppressed FSE and FR-FSE sequences. Lesion conspicuity, liver edge sharpness, and clarity of vessels were superior and ghosting was less with the FR-FSE sequences compared with the FSE sequences. CONCLUSION: Breath-hold FR-FSE technique is a reasonable alternative in T2-weighted imaging of the liver.  相似文献   

18.
A hypertensive patient was examined by CT and magnetic resonance (0.5 T) within 3 h from stroke onset. Computed tomography revealed a thalamocapsular hemorrhage. Hematoma was isointense to the white matter on T1-weighted and hyperintense on T2-weighted spin echo images. The T2-weighted gradient echo images showed a mixture of hypointense and hyperintense signal. This latter aspect has not previously been reported and is probably related to abundant intracellular deoxyhemoglobin in clotted areas rich in red blood cells.  相似文献   

19.
We investigated the usefulness of echo-planar imaging (EPI) as well as T2*-weighted and diffusion-weighted MRI (DWI) to identify hyperacute hemorrhage (within 24 h after ictus) in the brain. Seven patients were examined 3.5 to 24 h after onset of symptoms using a whole-body 1.5-T MR system. Two diffusion-weighted sequences were run to obtain isotropic and anisotropic diffusion images. Apparent diffusion coefficients (ADC) were calculated from the isotropic diffusion images. All DWI images as well as the T2*-weighted EPI images showed the hematomas as either discrete, deeply hypointense homogeneous lesions, or as lesions of mixed signal intensity containing hypointense areas. We conclude that even in the early phase after hemorrhage, sufficient amounts of paramagnetic deoxyhemoglobin are present in intracerebral hemorrhages to cause hypointensity on EPI T2*-weighted and DWI images; thus, use of ultrafast EPI allows identification of intracerebral hemorrhage. Received: 21 March 2000 Revised: 26 July 2000 Accepted: 27 July 2000  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号