首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
BackgroundThe use of endoluminal stents has been proposed for the management of fistulas and anastomotic strictures after bariatric surgery. The objective of our study was to determine the success of endoscopically placed, self-expandable metal stents (SEMS) in bariatric patients specifically with either chronic persistent anastomotic or staple line leaks/fistulas or chronic, persistent anastomotic strictures.MethodsWe treated 21 patients including 5 with chronic staple line leaks/fistulas (4 from the gastric sleeve after biliopancreatic diversion with duodenal switch [BPD/DS] and 1 after removal of an eroding laparoscopic adjustable gastric band) and 16 with chronic anastomotic strictures (15 at the gastrojejunostomy after Roux-en-Y gastric bypass and 1 at the duodenoileal anastomosis after BPD/DS). Patients with early leaks or anastomotic strictures were excluded.ResultsAll but one of these patients had been referred to our institution after chronic treatment elsewhere was unsuccessful with prior stent placement for fistulas or multiple endoscopic dilations for strictures. Their bariatric operations had been performed a mean of 386 days beforehand. Stent placement was performed successfully in all patients without complications but was successful in only 4 of 21 patients (19%)—2 with chronic fistulas and 2 with chronic anastomotic strictures. Stent migration occurred in 10 patients (47%); the migrated stents were removed/replaced endoscopically in 7 patients but required elective operative removal in 3 with concomitant correction of the leak, fistula, or anastomotic stricture; none were operated emergently.ConclusionOnly 4 of 21 patients with a chronic persistent leak or anastomotic stricture were treated definitively using a SEMS. Although endoluminal stents may not lead to resolution of a chronic leak or stricture, SEMS may suppress ongoing sepsis and allow patients to undergo nutritional resuscitation orally before operative correction.  相似文献   

2.

Background

Leaks occurring after weight loss operations constitute a therapeutic challenge. There is no consensus as to what comprises state-of-the-art management of leaks after bariatric surgery. We sought to determine the efficacy and possible adverse effects of endoluminal stenting for leaks after bariatric surgery.

Methods

We report our experience with the stent treatment of consecutive bariatric patients with a leak (retrospective cohort study). Between October 2005 and July 2010, 47 patients presented an acute leak after a bariatric procedure (61 % primary procedures, 39 % revisions). Fifteen patients were initially approached laparoscopically, and 32 were treated by nonoperative techniques. After adequate drainage and resuscitation, all 47 patients were treated by the endoscopic placement of a partially covered metallic stent, and later of a plastic stent inside the metallic prosthesis to facilitate removal. Both stents were then ablated 1 week later. Primary outcome measurement concerned healing of the fistula, as evidenced by radiographic imaging. Secondary outcomes were length of hospital stay and occurrence of peri- and postprocedural complications.

Results

There was no mortality. 41 patients (87.23 %) healed with stent treatment alone; 5 of the 6 persisting leaks healed with laparoscopic intervention (intention-to-treat success rate 96 %). Complication rate was 28.7 %. Length of hospital stay was mean ± standard deviation 22.4 ± 19.38 days for the patients treated by stent alone, and 23.4 ± 18.4 days for the patients requiring additional surgery (P = NS). One patient developed a stricture and required endoscopic dilation, and one is still awaiting surgical treatment.

Conclusions

Leaks after bariatric surgery can be treated safely and effectively by endoscopic stents. In cases of persisting leaks, laparoscopic intervention is successful in a majority of cases. Late strictures seldom occur.  相似文献   

3.

Background

Laparoscopic sleeve gastrectomy has become a very frequent procedure in bariatric surgery due to its efficacy and simplicity compared to gastric bypass. Gastric staple line leak (1 to 7 % of cases) is a severe complication with a long nonstandardized treatment. The aim of this retrospective study was to examine the success and tolerance of covered stents in its management.

Methods

From January 2009 to December 2011, nine patients with gastric staple line leaks after sleeve gastrectomy were treated with covered stents in our department (seven referred from other institutions). The leaks were diagnosed by CT scan and visualized during the endoscopy. Among the studied variables were operative technique, post-operative fistula diagnosis delay, stent treatment delay, and stent tolerance. In our institution, Hanarostent® (length 17 cm, diameter 18 mm; M.I. Tech, Seoul, Korea) was used and inserted under direct endoscopic control.

Results

Stent treatment was successful in seven cases (78 %). Two other cases had total gastrectomy (405 and 185 days after leak diagnosis). Early stent removal (due to migration or poor tolerance) was necessary in three cases. The average stent treatment duration was of 6.4 weeks, and the average healing time was 141 days. The five patients with an early stent treatment (≤3 weeks after leak diagnosis) had an average healing time of 99 days versus 224 for the four others.

Conclusions

Covered self-expandable stent is an effective treatment of gastric leaks after sleeve gastrectomy. Early stent treatment seems to be associated with shorter healing time.  相似文献   

4.

Background

Anastomotic leakages are severe complications of upper gastrointestinal surgery with serious morbidity and mortality. Until recently, only abscess drainage was possible. Since 2007, removable and repositionable covered metal self-expandable stents (RReCoMSeS) have been used in our hospital to cover leaks.

Methods

Patients with postsurgical gastrointestinal leaks treated with RReCoMSeS between January 2007 and March 2010 were retrospectively evaluated and described.

Results

Twenty-six patients were treated with RReCoMSeS (totally covered Choo/Hanaro and partially covered Endoflex stents). Included patients had anastomotic leaks after esophagectomy (15) and bariatric surgery (11). Overall successful sealing of the leak occurred in 81 % (including multiple procedures). In total 33 RReCoMSeS were used (mean 1.3 stents and 1.7 procedures per patient). Twenty-one of 33 RReCoMSeS succeeded in sealing the leak (64 %). Migration occurred in 24 % RReCoMSeS, and 9 % disintegrated. One stent (3 %) caused a perforation.

Conclusions

RReCoMSeS are a safe alternative for treating postsurgical leaks in the upper gastrointestinal tract. In 81 % of patients and with 64 % of the inserted stents, leaks were sealed successfully, with few complications. Fewer stents per patient were needed thanks to their repositionability. Stent migration is a major problem.  相似文献   

5.

Background

We hypothesized that an esophageal nitinol stent that is mainly silicone-covered but partially uncovered may allow tissue ingrowth and decrease the migration rate seen with fully covered stents and still allow safe stent removal. The aim of this study was to evaluate the first human results of using partially covered stents for anastomotic complications of bariatric surgery.

Methods

This was a retrospective evaluation of all patients with staple-line complications after bariatric surgery who received a partly covered stent at a single tertiary-care bariatric center. The stents varied in length from 10 to 15 cm and in diameter from 18 to 23 mm.

Results

From April 2009 to April 2010, eight patients received partially covered stents on 14 separate occasions. The indications were gastrojejunal stricture in four, acute leak in two, acute leak followed by a later stricture in one, and a perforated anastomotic ulcer in one patient. Single stents were placed in 12 sessions and two overlapping stents in two sessions. At the time of stent deployment, one patient had the uncovered proximal end of the stent in the stomach, with all others in the distal esophagus. Immediate symptom improvement occurred in 12/14 stent placements. Oral nutrition was initiated for 10/14 stent treatments within 48 h. Stents were removed after 25 ± 10 days. Minor stent displacement occurred with 9/13 stents, with the proximal end of the stent moving into the stomach, though the site of pathology remained covered. The stents were difficult to remove when tissue ingrowth was present. One patient required laparoscopic removal and one required two endoscopy sessions for removal. At the time of removal of ten stents, where the proximal end was found in the stomach, four had gastric ulceration, three had gastric mucosa replaced by granulation tissue, and three had normal gastric mucosa. In four cases where the proximal portion of the stent stayed in the esophagus, the esophageal deployment zone had abnormalities: three with granulation tissue and one with denuding of the esophageal mucosa. The distal uncovered portion of the stent in the Roux limb never became embedded in the mucosa and caused minimal injury.

Conclusions

A partially covered stent was successful in keeping the site of the pathology covered and provided rapid symptom improvement and oral nutrition in most patients. The proximal end of the stent generally moved from the esophagus to the stomach, probably due to esophageal peristalsis. The proximal uncovered portion of the stent causes significant bowel mucosal injury and sometimes becomes embedded in the esophagus or the stomach, making removal difficult. We no longer use partially covered stents.  相似文献   

6.

Background

Self-expandable metal stents (SEMS) and self-expandable plastic stents (SEPS) maybe used for the treatment of benign upper gastrointestinal (GI) leaks and strictures. This study reviewed our experience with stent insertions in patients with benign upper GI conditions.

Methods

Patients who underwent stent placement for benign upper GI strictures and leaks between March 2007 and April 2011 at a tertiary referral academic center were studied using an endoscopic database and electronic patient records. The technical success, complications, and clinical improvement after stent removal were compared according to type of stent. The outcomes measured were clinical response, adverse events, and predictors of stent migration.

Results

Thirty-eight patients (50 % male, mean age = 54 years, range = 12–82) underwent 121 endoscopic procedures. Twenty patients had stents placed for strictures, and 18 had stents placed for leaks. Stent placement was technically successful in all patients. The average duration of stent placement was 54 days (range = 18–118). Clinical improvement immediately after stent placement was seen in 29 of the 38 patients (76.3 %). Immediate post-procedure adverse events occurred in 8 patients. Late adverse events were seen in 18 patients. Evidence of stent migration occurred in 16 patients and was seen in 42 of the 118 successfully placed stents (35.5 %). Migration was more frequent with fully covered SEMS (p = 0.002). After stent removal, 27 patients were evaluable for long-term success (median follow-up time of 283 days, IQR 38–762). Resolution of strictures or leaks was seen in 11 patients (40.7 %). Predictors for long-term success included increasing age and if the stent did not cross the GE junction.

Conclusions

Placement of SEPS and SEMS for benign refractory strictures and fistulas has modest long-term clinical efficacy and is limited by a significant migration rate. Stent migration is common and frequent with fully covered SEMS compared to other types of stents, regardless of indication or location.  相似文献   

7.
BACKGROUND: This study examined the feasibility of using Polyflex stents in the treatment of enteric leaks after various bariatric operations. Chronic and acute leaks were treated. METHODS: We performed a retrospective case series review. Four patients received 6 Polyflex stents to treat complications of bariatric surgery. Two presented with early sepsis before stenting. One presented with abdominal pain. One presented with a chronic persistent fistula with an associated abscess. Stenting was performed under endoscopy with fluoroscopic guidance. The stents were left in place for 6 weeks. RESULTS: All patients tolerated a clear liquid diet within 24 hours of stenting and were able to be advanced to a pureed diet. All patients improved clinically after stenting. Three patients with acute leaks sealed their leaks after stent placement. One patient with a chronic leak persisted and required operative closure after a second stent was placed and failed. All patients experienced short-term nausea, as well as early satiety that lasted the duration of the stenting. One patient experienced hypersialisis while the stent was in place. Two stents migrated, although this had no effect on leak closure. One patient had an anastomotic stenosis successfully treated with a second stent. CONCLUSIONS: Polyflex stents are useful in bypassing acute upper intestinal leaks after various bariatric operations. They provide a temporary bridge for wound healing with continued oral intake. Stenting provides a minimally invasive option in the management of acute leaks and, in our experience, had no serious associated morbidity.  相似文献   

8.
Background Esophageal stenting has become an important technique in the treatment of different clincal problems such as malignant or benign stenosis, anastomotic leaks after surgery, or fistulas. In this study we present our experience with the self-expanding Polyflex plastic stent in various indications, arising complications, and patient’s outcomes. Methods Over a three-year period, 35 patients underwent self-expanding Polyflex plastic stent placement for esophageal stenosis (n = 23) with 22 malignant, and for perforations, fistulas, or anastomotic leaks after surgery (n = 12). The short-term efficacy and long-term outcomes were analyzed. Results In patients with stenosis, implantation was performed without any complications in 91% (21/23). In one patient perforation occurred while passing the stenosis; in another patient the stent dislocated during the insertion procedure. Dysphagia score improved from 3.0 to 1.0 after stenting. In all patients with perforations, fistulas, or anastomotic leaks (n = 12), stents were placed successfully without any complication. Complete sealing of the mucosal defect was proven by radiography in 92% (n = 11) and healing was seen in 42% (n = 5). If indicated, stent removal was performed without any complications. Stent migration (n = 13; 37%) was the most common long-term complication. Conclusions The placement of self-expanding Polyflex plastic stents is a highly sufficient and cost-effective treatment for malignant and benign esophageal disorders. Because the long-term results were highly favorable, self-expanding plastic stent placement could be used as the initial treatment for various conditions.  相似文献   

9.
INTRODUCTION: Despite improved survival, biliary complications remain a significant cause of morbidity following orthotopic liver transplantation. The aim of this study was to review the incidence, treatment and optimum management pathway of biliary complications at the Scottish Liver Transplant Unit. MATERIALS AND METHODS: All patient data were collected prospectively onto a database at the Scottish Liver Transplant Unit with review of hospital records for validation. RESULTS: A total of 379 consecutive orthotopic liver transplants were performed in 333 adult patients between November 1992 and September 2001. Biliary complications occurred in 55 grafts (51 patients) (14.6%) and their incidence decreased with time. Biliary complications occurred in 29 (10.9%) of the 265 choledocho-choledochostomies compared with 14 (25%) of the 56 with T-tubes. Twenty-eight biliary leaks occurred, 22 of which were anastomotic. Seventeen anastomotic leaks were successfully treated non-operatively. Eight patients with biliary leaks subsequently developed an anastomotic stricture. Of the 30 anastomotic strictures, stent insertion was successful in resolving six of 14 (42%) early anastomotic strictures compared with one of 12 (8%) late anastomotic strictures (p = 0.0479). Six (38%) of the 16 early anastomotic strictures required surgery for complete resolution, compared with 12 (86%) of the 14 late anastomotic strictures (p = 0.0106). CONCLUSION: The incidence of biliary complications has decreased with time. The abandonment of choledocho-choledochostomy over a T-tube has been justified. A combination of conservative, endoscopic, and radiological management has been effective in treating biliary leaks and early anastomotic stricture. However endoscopic or radiological stenting was ineffective in the management of late anastomotic strictures, which were best treated by surgical intervention.  相似文献   

10.

Introduction

Anastomotic complications after esophagectomy are relatively frequent. The off-label use of self-expanding covered metal stents has been shown to be an effective initial treatment for leaks, but there is a paucity of literature regarding their use in cervical esophagogastric anastomoses. We reviewed our outcomes with anastomotic stenting after esophagectomy with cervical esophagogastric reconstruction.

Methods

All stents placed across cervical anastomoses following esophagectomy from 2004 to 2014 were retrospectively reviewed. Indications for surgery and stent placement were collected. For patients with serial stents, each stent event was evaluated separately and as part of its series. Success was defined as resolution of indicated anastomotic problem for at least 90 days. Complications were defined as development of stent-related problems.

Results

Twenty-three patients had a total of 63 stents placed (16 % prophylactic, 38 % leak, 46 % stricture). Sixty percent of patients had successful resolution of their initial anastomotic problem; 67 % required more than one stent. Strictures and leaks healed in 27 and 70 % of patients, respectively, at a median of 55.5 days. Stent-related complications occurred in 78 % of patients. Complications (per stent event) included 62 % migration, 11 % clinically significant tissue overgrowth, 8 % minor erosion (ulcers), and 8 % major erosion. Stents placed for stricture were more likely to result in complications, especially migration (76.7 vs. 48.5 %, p = 0.02). Preoperative chemoradiation was a significant risk factor for erosion (22.5 vs. 4.3 %, p = 0.05), but not for overall complications. Patients with major erosions had longer stent duration compared to those without (92 vs. 36 days, p = 0.14).

Discussion

Although stents are effective at controlling post-esophagectomy anastomotic leaks, they are not effective for treating strictures. Stents have high complication rates, but most are minor. Chemoradiation is a risk factor for stent erosion. Caution should be used when stent duration exceeds 2–3 months due to the risk of erosion.
  相似文献   

11.
BackgroundStaple line leaks and bleeding, anastomotic strictures, and marginal ulcers are significant complications of Roux-en-Y gastric bypass (RYGB) for morbid obesity. Reinforcing the staple lines with bovine collagen matrix reinforcement (CMR) might safely decrease the incidence of leaks and bleeding without causing other complications. Our objective was to determine the effect in RYGB of reinforcing the linear and circular gastric staple lines with CMR on the outcomes including abdominal septic events, blood transfusions, and the incidence of stricture and marginal ulceration of the gastrojejunostomy in a private bariatric surgery practice at 2 Surgical Review Committee Center of Excellence community hospitals.MethodsWe performed a retrospective review of prospectively collected data comparing consecutive outcomes of 505 patients undergoing RYGB without CMR from 2005 to 2006 to 568 patients with CMR of the linear and circular gastric staple lines from 2007 to 2009.ResultsThe application of CMR was associated with a significant reduction from 4% to 1% in the incidence of abdominal septic events, including frank staple line leakage, purulent drainage, and abscess. The number of patients needing transfusion showed a trend downward. The frequency of stricture (1%) and marginal ulceration (2%) was unchanged. No gastrogastric fistulas were identified in either group. No evidence of migration of collagen matrix material appeared after CMR. The 90-day mortality rate for each group was .2% and was unrelated to staple line complications.ConclusionThe use of CMR was associated with a significant reduction in the incidence of abdominal septic complications and a trend toward fewer patients needing transfusion. The frequency of stricture and marginal ulceration was unchanged by the use of CMR.  相似文献   

12.
Background Historically, esophageal fistulas, perforations, and benign and malignant strictures have been managed surgically or with the placement of permanent endoprostheses or metallic stents. Recently, a removable, self-expanding, plastic stent has become available. The authors investigated the use of this new stent at their institution. Methods The study reviewed all the patients who received a Polyflex stent for an esophageal indication at the authors’ institution between January 2004 and October 2006. Duration of placement, complications, and treatment efficacy were recorded. Results A total of 37 stents were placed in 30 patients (14 women and 16 men) with a mean age of 68 years (range, 28–92 years). Stent placement included 7 for fistulas, 3 for perforations, 1 for an anastomotic leak, 7 for malignant strictures, and 19 for benign strictures (8 anastomotic, 1 caustic, 5 reflux, 2 radiation, and 2 autoimmune esophagitis strictures, and 1 post-Nissen gas bloat stricture). The mean follow-up period was 6 months. Stent deployment was successful for all the patients, and no complications resulted from stent placement or removal. Nine stents migrated spontaneously. Three of three perforations and three of five fistulas sealed. Only one stent was removed because of patient discomfort. One patient with a radiation stricture experienced tracheoesophageal fistulas secondary to pressure necrosis. Of 20 patients with stricture, 18 experienced improvement in their dysphagia. Conclusion Self-expanding, removable plastic stents are easily and safely placed and removed from the esophagus. This has facilitated their use in the authors’ institution for an increasing number of esophageal conditions. Further studies to help define their ultimate role in benign and malignant esophageal pathology are warranted.  相似文献   

13.
BackgroundDue to the large number of laparoscopic sleeve gastrectomy (LSG) performed over the last decade, the management of the leak following LSG has been increasingly reported. The role of covered Self Expandable Metal Stents (cSEMS) for the treatment of the leak is still controversial because of the poor tolerance and high risk of complications.ObjectivesThe aim of the present study was to analyze the foregut wall perforation and aorta injuries, a very rare but potentially fatal complication, related to the treatment of the leak following LSG using cSEMS.SettingPrivate hospital, France.MethodsAn audit was conducted in 2 French tertiary bariatric endoscopic centers focusing on aortic injuries after cSEMS use for leak. We examined and classified the initial procedure, leak characteristics, primary endoscopic treatment, and outcome of endoscopic complication for each eligible case.ResultsA total of 5 patients were identified with foregut wall perforation and aorta injuries. All stents were deployed for staple line leak following LSG. The recorded mortality in case of esophageal-aortic injuries related to cSEMS use was 80%.ConclusioncSEMS are potentially effective tools for the management of foregut leaks in bariatric surgery. The biggest challenges with this approach are stent migration and poor quality of life. Caution is required due to the risk of fatal complications such as foregut wall perforation and aortic injury.  相似文献   

14.
Complications after esophagogastrectomy using stapling instruments   总被引:5,自引:0,他引:5  
We studied 195 patients undergoing esophageal resection using stapling instruments during a period of over 8.5 years. Of these, 178 (91.2%) underwent operation for malignant disease. Operative death occurred in 19 patients (9.7%). Nine (4.6%) postoperative complications, excluding stricture formation, were related to the use of stapling instruments, including two operative deaths (1.0%). Anastomotic leaks and gastrotomy staple line leaks were the most common complications (four each). In 7 patients (3.6%) the circular stapler tore the esophagus; anastomotic leaks subsequently developed in 43% of these patients. After we began oversewing gastrotomy staple lines in 1984, we experienced only one gastrotomy leak due to a technical error. Postoperative stricture formation occurred soon after resection and responded well to one or two dilations. It is better to err on the side of choosing too small a stapling head when performing an esophageal anastomosis because this may reduce the incidence of leaks, and further strictures are easily dealt with.  相似文献   

15.

Background

Laparoscopic sleeve gastrectomy (LSG) is one of the most commonly performed bariatric procedures for treatment of morbid obesity. Despite its popularity, it is not without risks, the most serious of which is the staple line leak. Staple line leaks are difficult to manage and require significant resources in the form of surgical, radiological and endoscopic interventions; long hospital and intensive care stay and significant morbidity. International experience is slowly emerging, but there are still no clear guidelines regarding optimal management of leaks. This study aims to describe the experience of endoscopic management of these leaks by the authors and the development of a customised stent for this condition.

Methods

Middlemore Hospital is the largest bariatric surgery centre in New Zealand. Since June 2007, a total of 21 patients have received endotherapy for post-LSG leak management. Treatment included the deployment of primary self-expanding metal stents (SEMS) across the leak site, combined with complementary endoscopic modalities. Persistent leaks were treated with follow-up stenting. This study aimed to evaluate the effectiveness of post-LSG staple line leak management at Middlemore Hospital.

Results

A total of 20/21 (95 %) patients now have resolved leaks following a mean of 75 days of treatment (median 47, range 9–187). The mean number of endoscopic procedures required was five. Inpatient stay and average duration till leak resolution has been notably reduced since the addition of customised stents. Clinically significant stent migration occurred in 19 % of primary stents.

Conclusion

The use of SEMS in conjunction with complementary endotherapy has shown to be both safe and effective in treating sleeve leaks; however, migration is the limiting factor for optimal management. Recent improvements in stent design, such as the one proposed in this paper, show promise in addressing this problem. Earlier use of SEMS seems to reduce the time till closure as well as the total hospital stay, as is apparent from our data.
  相似文献   

16.

Background

Self-expandable metallic stents can be used to treat patients with symptomatic anastomotic complications after colorectal resection.

Methods

Twenty patients with symptomatic anastomotic stricture after colorectal resection were treated with endoscopic placement of a self-expandable metal stent. Ten patients had “simple” anastomotic stricture. In the remaining 10 patients, a leak was associated with the stricture.

Results

The anastomotic leakage healed without evidence of residual stricture or major fecal incontinence in 8 of 10 patients. Overall, the anastomotic stricture was resolved in 14 of the 20 patients.

Conclusions

Self-expandable metal stents represent a valid adjunctive to treat patients with symptomatic anastomotic complications after colorectal resection for cancer. They have a complementary role to balloon dilatation in case of simple anastomotic stricture, and they improve the rate of healing when the stricture is associated with a leak.  相似文献   

17.
Jones WB  Myers KM  Traxler LB  Bour ES 《The American surgeon》2008,74(6):462-7; discussion 467-8
Although linear surgical staple line reinforcement has been shown to increase anastomotic tensile strength in animal models and reduce the incidence of staple line bleeding and anastomotic leaks in colorectal surgery, the benefits of staple line reinforcement on circular stapled anastomoses in bariatric surgery remain unreported in the literature. The purpose if this study was to compare the incidence of anastomotic bleeding, leak, and stricture in patients undergoing laparoscopic gastric bypass with circular staple line reinforcements with those with no circular staple line reinforcements. Since May 2006, 138 consecutive patients (Group B) have undergone laparoscopic Roux-en-Y divided gastric bypass with a 25-mm circular stapled gastrojejunal anastomosis using GORE SEAMGUARD bioabsorbable circular staple line reinforcement (CBSG) with a mean follow up of 9 months. The incidence of anastomotic bleeding, leak, and stricture was compared with 255 similar patients (Group A) who underwent surgery before May 2006 without gastrojejunal reinforcement with a mean follow up of 22 months. The rates of anastomotic bleeding, leak, and stricture for Group B versus Group A were 0.7 per cent versus 1.1 per cent (P = 0.64); 0.7 per cent versus 1.9 per cent (P = 0.34); and 0.7 per cent versus 9.3 per cent (P = 0.0005), respectively. The use of CBSG reduced the incidence of anastomotic stricture by 93 per cent and the incidence of a composite end point of all anastomotic complications by 85 per cent. Our results indicate that the use of circular staple line reinforcement at the gastrojejunal anastomosis in patients undergoing laparoscopic gastric bypass significantly decreases the incidence of anastomotic stricture and a composite end point of all anastomotic complications. On this basis, strong consideration should be given to the routine use of CBSG staple line reinforcement in patients undergoing laparoscopic divided gastric bypass with a circular stapled gastrojejunal anastomosis.  相似文献   

18.
Stent placement in the management of oesophageal leaks   总被引:2,自引:0,他引:2  
Objective: To examine retrospectively the patients of our department who had a self-expandable totally covered metal stent placed for oesophageal leak. METHODS: Patients hospitalised in our department for oesophageal cancer and/or oesophageal perforation between 2004 and 2006. All medical records were retrospectively reviewed. Seventy-two patients underwent oesophageal resection for oesophageal cancer and 16 were managed for oesophageal perforations. RESULTS: Eight out of 72 patients submitted to resection for oesophageal cancer had postoperative leaks, while one patient developed tracheo-oesophageal fistula (TEF) due to prolonged mechanical ventilation. Six of them had stent placement in first intention, whereas two received the procedure after an unsuccessful repeat operation. The mean stent placement time was 18.4 days (SD=15.2 days), whereas the median was 14 days. The leak was managed efficiently by the stent in seven patients, whereas two patients needed repeat operations (one with TEF). The mean stent removal time was 56.8 days (SD=30.5 days) and the median was 40 days. None developed anastomotic stricture. On the other hand, three out of 16 patients with perforation had a stent, two of them for Boerhaave syndrome and one for iatrogenic rupture after bariatric surgery. One of them required the stent 17 days after surgical repair with excellent results, while the other two patients had the stent placed immediately, but still needed thoracotomy to control the leak. CONCLUSIONS: Stent placement can prove very useful in the management of post-oesophagectomy anastomotic leaks, but its contribution needs to be evaluated with caution in cases of oesophageal perforations or TEF. Larger series and prospective comparative clinical trials could eventually clarify the role of stents in clinical practice of surgical patients.  相似文献   

19.
Background  Preoperative nutritional supplementation, management of esophageal leaks, and postoperative anastomotic strictures still remain common problems in the management of esophageal cancer. Jejunal feeding tubes, total parenteral nutrition (TPN) with nasogastric suction, and repeated esophageal dilations remain the most common treatments, respectively. The aim of this study was to evaluate the use of removable silicone stents in (1) the preoperative nutritional optimization during neoadjuvant therapy, (2) the management of perioperative anastomotic leak, and (3) the management of postoperative anastomotic strictures. Methods  Review of our prospectively maintained esophageal database identified 15 patients who had removable self-expanding silicone stents placed in the management of one of these three management problems from July 2004 to August 2006. Results  Preoperative therapy: Five patients underwent initial stent placement in preparation for neoadjuvant therapy. Dysphagia relief was seen in 100% of patients, with optimal caloric needs taken within 24 h of placement. All patients tolerated neoadjuvant therapy without delay from dehydration or malnutrition. One stent migration was found at the time of operation, which was removed without sequelae. Perioperative therapy: Five patients developed delayed (>10 days) esophageal leaks that were managed with removable esophageal stent and percutaneous drainage (in three patients). All patients had successful exclusion of the leak on the day of the procedure with resumption of oral intake on the evening of procedure. All five healed leaks without sequelae. Postoperative therapy: Five patients developed postoperative anastomotic strictures that required dilation and placement of removable esophageal stent. The median number of dilations was 1 (range 1–2), with all stents placed for approximate 3 months duration. All patients had immediate dysphagia relief after stent placement. Conclusion  Removable esophageal stents are novel treatment option to optimize relief of symptoms and return the patients back to a more normal oral intake. Continued evaluation is needed to consider stent use as first-line therapy.  相似文献   

20.

Background and Aims

Endoscopic stenting has proved effective in the management of post-surgical leaks but is strongly hampered by the high rate of stent migration. In this study, we evaluate our experience with a new approach involving the use of novel ultra-large expandable stents tailored for bariatric surgery leaks (Mega stents), combined with the use of the innovative over-the-scope clips (OTSC).

Methods

Retrospective analysis of patients with post-bariatric surgery leaks managed at our institution by an approach combining Mega stents and over-the-scope clips.

Results

Twenty-two patients were treated for post-bariatric surgery leaks; 13 (59 %) had a sleeve gastrectomy while nine (41 %) had a RYGB. A total of 30 stents were inserted. Successful endoscopic insertion and removal were achieved in all patients. OTSC clips were applied in 12 patients (55 %); five simultaneously with stents and seven after stent removal. Primary closure (after one endoscopic procedure) was achieved in 13 patients (59 %) and in a total of 18 patients after multiple endoscopic procedures (82 %). An average of 1.4 stents and 2.8 endoscopic procedures were required per patient. Stent migration occurred in four patients (18 %), and all were retrievable endoscopically. Other complications included retrosternal pain and vomiting in 20 patients (91 %) including one necessitating early removal, bleeding in two patients (9 %), and perforation and esophageal stricture in one patient each (5 %). Two mortalities were encountered, and one of them was stent-related (bleeding).

Conclusion

Mega stents are effective in the management of post-bariatric surgery leaks. The combined use of Mega stents and OTSC clips is associated with a low incidence of migration and a low number of stents and procedures required per patient.
  相似文献   