首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
The objective was to design a vascular phantom compatible with digital subtraction angiography, computerized tomography angiography, ultrasound and magnetic resonance angiography (MRA). Fiducial markers were implanted at precise known locations in the phantom to facilitate identification and orientation of plane views from three-dimensional (3-D) reconstructed images. A vascular conduit connected to tubing at the extremities of the phantom ran through an agar-based gel filling it. A vessel wall in latex was included around the conduit to avoid diffusion of contrast agents. Using a lost-material casting technique based on a low melting point metal, geometries of pathological vessels were modeled. During the experimental testing, fiducial markers were detectable in all modalities without distortion. No leak of gadolinium through the vascular wall was observed on MRA after 5 hours. Moreover, no significant deformation of the vascular conduit was noted during the fabrication process (confirmed by microtome slicing along the vessel). The potential use of the phantom for calibration, rescaling, and fusion of 3-D images obtained from the different modalities as well as its use for the evaluation of intra- and inter-modality comparative studies of imaging systems are discussed. In conclusion, the vascular phantom can allow accurate calibration of radiological imaging devices based on x-ray, magnetic resonance and ultrasound and quantitative comparisons of the geometric accuracy of the vessel lumen obtained with each of these methods on a given well defined 3-D geometry.  相似文献   

2.
We present a technique that accurately reconstructs complex three dimensional blood vessel geometry from 2D intravascular ultrasound (IVUS) images. Biplane x-ray fluoroscopy is used to image the ultrasound catheter tip at a few key points along its path as the catheter is pulled through the blood vessel. An interpolating spline describes the continuous catheter path. The IVUS images are located orthogonal to the path, resulting in a non-uniform structured scalar volume of echo densities. Isocontour surfaces are used to view the vessel geometry, while transparency and clipping enable interactive exploration of interior structures. The two geometries studied are a bovine artery vascular graft having U-shape and a constriction, and a canine carotid artery having multiple branches and a constriction. Accuracy of the reconstructions is established by comparing the reconstructions to (1) silicone moulds of the vessel interior, (2) biplane x-ray images, and (3) the original echo images. Excellent shape and geometry correspondence was observed in both geometries. Quantitative measurements made at key locations of the 3D reconstructions also were in good agreement with those made in silicone moulds. The proposed technique is easily adoptable in clinical practice, since it uses x-rays with minimal exposure and existing IVUS technology.  相似文献   

3.
We present a technique that accurately reconstructs complex three dimensional blood vessel geometry from 2D intravascular ultrasound (IVUS) images. Biplane x-ray fluoroscopy is used to imagethe ultrasound catheter tip at a few key points along its path as the catheter is pulled through the blood vessel. An interpolating spline describes the continuous catheterpath. The IVUS images are located orthogonal to the path, resulting in a non-uniform structured scalar volume of echo densities. Isocontour surfaces are used to view the vessel geometry, while transparency and clipping enable interactive exploration of interior structures. The two geometries studied are a bovine artery vascular graft having U-shapeand a constriction, and a canine carotid artery having multiple branches and a constriction. Accuracy of the reconstructions is established by comparing the reconstructions to (1) silicone moulds of the vessel interior, (2) biplane x-ray images, and (3) the original echo images. Excellent shape and geometry correspondence was observed in both geometries. Quantitative measurements made at key locations of the 3D reconstructions also were in good agreement with those made in silicone moulds. The proposed technique is easily adoptable in clinical practice, since it uses x-rays with minimal exposure and existing IVUS technology.  相似文献   

4.
As interventional procedures become more complicated, the need for accurate quantitative vascular information increases. In response to this need, many commercial vendors provide techniques for measurement of vessel sizes, usually based on derivative techniques. In this study, we investigate the accuracy of several techniques used in the measurement of vessel size. Simulated images of vessels having circular cross sections were generated and convolved with various focal spot distributions taking into account the magnification. These vessel images were then convolved with Gaussian image detector line spread functions (LSFs). Additionally, images of a phantom containing vessels with a range of diameters were acquired for the 4.5", 6", 9", and 12" modes of an image intensifier-TV (II-TV) system. Vessel sizes in the images were determined using a first-derivative technique, a second-derivative technique, a linear combination of these two measured sizes, a thresholding technique, a densitometric technique, and a model-based technique. For the same focal spot size, the shape of the focal spot distribution does not affect measured vessel sizes except at large magnifications. For vessels with diameters larger than the full-width-at-half-maximum (FWHM) of the LSF, accurate vessel sizes (errors approximately 0.1 mm) could be obtained by using an average of sizes determined by the first and second derivatives. For vessels with diameters smaller than the FWHM of the LSF, the densitometric and model-based techniques can provide accurate vessel sizes when these techniques are properly calibrated.  相似文献   

5.
In transrectal ultrasound (TRUS) guided prostate seed brachytherapy, TRUS provides good delineation of the prostate while x-ray imaging, e.g., C-arm, gives excellent contrast for seed localization. With the recent availability of cone beam CT (CBCT) technology, the combination of the two imaging modalities may provide an ideal system for intraoperative dosimetric feedback during implantation. A dual modality phantom made of acrylic and copper wire was designed to measure the accuracy and precision of image coregistration between a C-arm based CBCT and 3D TRUS. The phantom was scanned with TRUS and CBCT under the same setup condition. Successive parallel transverse ultrasound (US) images were acquired through manual stepping of the US probe across the phantom at an increment of 1 mm over 7.5 cm. The CBCT imaging was done with three reconstructed slice thicknesses (0.4, 0.8, and 1.6 mm) as well as at three different tilt angles (0 degrees, 15 degrees, 30 degrees), and the coregistration between CBCT and US images was done using the Variseed system based on four fiducial markers. Fiducial localization error (FLE), fiducial registration error (FRE), and target registration error (TRE) were calculated for all registered image sets. Results showed that FLE were typically less than 0.4 mm, FRE were less than 0.5 mm, and TRE were typically less than 1 mm within the range of operation for prostate implant (i.e., < 6 cm to surface of US probe). An analysis of variance test showed no significant difference in TRE for the CBCT-US fusion among the three slice thicknesses (p = 0.37). As a comparison, the experiment was repeated with a US-conventional CT scanner combination. No significant difference in TRE was noted between the US-conventional CT fusion and that for all three CBCT image slice thicknesses (p = 0.21). CBCT imaging was also performed at three different C-arm tilt angles of 0 degrees, 15 degrees and 30 degrees and reconstructed at a slice thickness of 0.8 mm. There is no significant difference in TRE between 0 degrees and 15 degrees (p = 0.191) as well as between 0 degrees and 30 degrees (p = 0.275), which suggests that the C-arm may be tilted intraoperatively to acquire CBCT images without compromising the quality of image fusion. The results conclude a high degree of accuracy and precision for the CBCT-TRUS fusion, which could be useful toward achieving real time intraoperative dosimetry in prostate brachytherapy.  相似文献   

6.
The purpose of this study is to characterize the x-ray properties of a dual-modality, anthropomorphic breast phantom whose MRI properties have been previously evaluated. The goal of this phantom is to provide a platform for optimization and standardization of two- and three-dimensional x-ray and MRI breast imaging modalities for the purpose of lesion detection and discrimination. The phantom is constructed using a mixture of lard and egg whites, resulting in a variable, tissue-mimicking structure with separate adipose- and glandular-mimicking components. The phantom can be produced with either a compressed or uncompressed shape. Mass attenuation coefficients of the phantom materials were estimated using elemental compositions from the USDA National Nutrient Database for Standard Reference and the atomic interaction models from the Monte Carlo code PENELOPE and compared with human values from the literature. The image structure was examined quantitatively by calculating and comparing spatial covariance matrices of the phantom and patient mammography images. Finally, a computerized version of the phantom was created by segmenting a computed tomography scan and used to simulate x-ray scatter of the phantom in a mammography geometry. Mass attenuation coefficients of the phantom materials were within 20% and 15% of the values for adipose and glandular tissues, respectively, which is within the estimation error of these values. Matching was improved at higher energies (>20 keV). Tissue structures in the phantom have a size similar to those in the patient data, but are slightly larger on average. Correlations in the patient data appear to be longer than those in the phantom data in the anterior-posterior direction; however, they are within the error bars of the measurement. Simulated scatter-to-primary ratio values of the phantom images were as high as 85% in some areas and were strongly affected by the heterogeneous nature of the phantom. Key physical x-ray properties of the phantom have been quantitatively evaluated and shown to be comparable to those of breast tissue. Since the MRI properties of the phantom have been previously evaluated, we believe it is a useful tool for quantitative evaluation of two- and three-dimensional x-ray and MRI breast imaging modalities for the purpose of lesion detection and characterization.  相似文献   

7.
提出一种基于血管匹配的三维超声与CT图像配准的新方法.首先,基于水平集方法自动分割出CT图像中的血管;其次,由于超声图像中的声影与血管均属于低回声区域,我们结合声影形成的物理原理及图像纹理特性,自动检测出声影区域,以提高配准的鲁棒性;最后,采用进化算法,将CT图像中分割出的血管与超声图像中低回声区域进行匹配.在肝脏体模和临床脾脏数据上进行了实验验证,自动配准的成功率在95%以上,平均目标配准误差在2 mm以内,实验结果验证了本方法的可行性.  相似文献   

8.
血管内超声(IVUS)图像是观测血管内部结构的首选影像学手段,基于IVUS图像的内膜和中外膜边界的提取是实现冠脉粥样硬化精准诊断的前提和关键。针对IVUS图像结构复杂、对比度低、边界提取困难等问题,本研究提出一种基于改进TransUnet网络的分割方法。首先,针对IVUS图像边界提取难点,对边血管、血管分叉、导丝伪像、阴影等4种图像结构进行建模,并基于建模结果予以定向数据增强;而后,结合IVUS图像的环状结构分布特点,在TransUnet网络中提出了Polar-bias归纳偏置的策略,并对IVUS图像进行像素级的分类;最后,基于分类结果优化GVF snake模型的外力场,进而提取IVUS图像的内膜和中外膜边界。采用国际标准IVUS图像数据集(两组不同中心频率,共512幅图像)对算法进行评测,引入JMard距离(JM),Hausdorff距离(HD)和面积差异百分比(PAD)等3个评测指标,在数据集A中JM为0.87, HD为0.87, PAD为0.18,数据集B中JM为0.91, HD为0.25, PAD为0.08。实验结果表明,所提出的算法在两组数据集的内膜及中外膜提取问题中的表现均...  相似文献   

9.
Both photoacoustic imaging and power Doppler ultrasound are capable of producing images of the vasculature of living subjects, however, the contrast mechanisms of the two modalities are very different. We present a quantitative and objective comparison of the two methods using phantom data, highlighting relative merits and shortcomings. An imaging system for combined photoacoustic and high-frequency power Doppler ultrasound microscopy is presented. This system uses a swept-scan 25-MHz ultrasound transducer with confocal dark-field laser illumination optics. A pulse-sequencer enables ultrasonic and laser pulses to be interlaced so that photoacoustic and power Doppler ultrasound images can be coregistered. Experiments are performed on flow phantoms with various combinations of vessel size, flow velocity, and optical wavelength. For the task of blood volume detection, power Doppler is seen to be advantageous for large vessels and high flow speeds. For small vessels with low flow speeds, photoacoustic imaging is seen to be more effective than power Doppler at the detection of blood as quantified by receiver operating characteristic analysis. A combination of the two modes could provide improved estimates of fractional blood volume in comparison with either mode used alone.  相似文献   

10.
A number of new methods are available for the measurement of large artery elastic properties in human subjects in vivo. One powerful tool which has recently been applied to the study of large artery mechanics is intravascular ultrasound (IVUS). IVUS studies are performed using a high frequency ultrasound transducer mounted on the tip of a catheter. This catheter is inserted into a blood vessel and detailed cross-sectional images of the vessel, are obtained from within the lumen. IVUS techniques have been used to study wall mechanics of the human aorta, as well as peripheral and coronary arteries in normal human subjects and in patients with vascular disease. This paper reviews IVUS studies of human arterial elasticity and discusses the strengths and weaknesses of this emerging technique as it is applied to the understanding of arterial mechanical properties.  相似文献   

11.
Intraoperative dosimetric quality assurance in prostate brachytherapy critically depends on discerning the three-dimensional (3D) locations of implanted seeds. The ability to reconstruct the implanted seeds intraoperatively will allow us to make immediate provisions for dosimetric deviations from the optimal implant plan. A method for seed reconstruction from segmented C-arm fluoroscopy images is proposed. The 3D coordinates of the implanted seeds can be calculated upon resolving the correspondence of seeds in multiple x-ray images. We formalize seed-matching as a combinatorial optimization problem, which has salient features: (a) extensively studied solutions by the computer science community; (b) proof for the nonexistence of any polynomial time exact algorithm; and (c) a practical pseudo-polynomial algorithm that mostly runs in O(N3) time using any number of images. We prove that two images are insufficient to correctly match the seeds, while a third image renders the matching problem to be of nonpolynomial complexity. We utilize the special structure of the problem and propose a pseudopolynomial time algorithm. Using three presegmented images, matching and reconstruction of brachytherapy seeds using the Hungarian algorithm achieved complete matching in simulation experiments; and 98.5% in phantom experiments. 3D reconstruction error for correctly matched seeds has a mean of 0.63 mm, and 0.9 mm for incorrectly matched seeds. The maximum seed reconstruction error in each implant was typically around 1.32 mm. Both on synthetic data and in phantom experiments, matching rate and reconstruction error achieved using presegmented images was found to be sufficient for prostate brachytherapy. The algorithm is extendable to deal with arbitrary number of images without any loss in speed or accuracy. The algorithm is sufficiently generic to provide a practical solution to any correspondence problem, across different imaging modalities and features.  相似文献   

12.
Clinical validation of quantitative coronary angiography (QCA) algorithms is difficult due to the lack of a simple alternative method for accurately measuring in vivo vessel dimensions. We address this problem by embedding simulated coronary artery segments with known geometry in clinical angiograms. Our vessel model accounts for the profile of the vessel, x-ray attenuation in the original background, and noise in the imaging system. We have compared diameter measurements of our computer simulated arteries with measurements of an x-ray Telescopic-Shaped Phantom (XTSP) with the same diameters. The results show that for both uniform and anthropomorphic backgrounds there is good agreement in the measured diameters of XTSP compared to the simulated arteries (Pearson's correlation coefficient 0.99). In addition, the difference in accuracy and precision of the true diameter measures compared to the XTSP and simulated artery diameters was small (mean absolute error across all diameters was < or = 0.11 mm +/- 0.09 mm).  相似文献   

13.
融合图像放疗靶区定位精度的检验和初步临床结果   总被引:1,自引:0,他引:1  
目的:探讨以图像融合技术为基础的肿瘤三维适形放疗靶区定位精度的检验及依据融合图像放疗靶区的确定与单纯CT影像放疗靶区确定的初步临床结果。方法:利用定制的模体分别行CT、MRI和PET成像,进行CT与MRI,CT与PET融合。检验融合后定制标记点的定位精度。对3例特殊病例分别以单纯CT图像为基础和融合图像为基础,进行三维适形放疗靶区认定,对不同医生之间和同一医生在不同时间,放疗靶区定义情况进行对照分析。结果:MRI/CT融合图像总定位精度小于2mm,PET/CT图像融合图像融合精度情况(包括同机融合和异机融合),采用不同的融合算法。定位精度有显著差异(P〈0.01,t=5.385)。单纯利用CT图像进行靶区的定义,不同医生之间,在不同的时间存在差异(P〈0.05),而采用融合技术可减少他们的争议和差异。结论:利用多模式图像融合可以提高靶区定义的准确性.有利于三维适形精确放射治疗。  相似文献   

14.
Jin JY  Ryu S  Faber K  Mikkelsen T  Chen Q  Li S  Movsas B 《Medical physics》2006,33(12):4557-4566
The purpose of this study was to evaluate the accuracy of a two-dimensional (2D) to three-dimensional (3D) image-fusion-guided target localization system and a mask based stereotactic system for fractionated stereotactic radiotherapy (FSRT) of cranial lesions. A commercial x-ray image guidance system originally developed for extracranial radiosurgery was used for FSRT of cranial lesions. The localization accuracy was quantitatively evaluated with an anthropomorphic head phantom implanted with eight small radiopaque markers (BBs) in different locations. The accuracy and its clinical reliability were also qualitatively evaluated for a total of 127 fractions in 12 patients with both kV x-ray images and MV portal films. The image-guided system was then used as a standard to evaluate the overall uncertainty and reproducibility of the head mask based stereotactic system in these patients. The phantom study demonstrated that the maximal random error of the image-guided target localization was +/-0.6 mm in each direction in terms of the 95% confidence interval (CI). The systematic error varied with measurement methods. It was approximately 0.4 mm, mainly in the longitudinal direction, for the kV x-ray method. There was a 0.5 mm systematic difference, primarily in the lateral direction, between the kV x-ray and the MV portal methods. The patient study suggested that the accuracy of the image-guided system in patients was comparable to that in the phantom. The overall uncertainty of the mask system was +/-4 mm, and the reproducibility was +/-2.9 mm in terms of 95% CI. The study demonstrated that the image guidance system provides accurate and precise target positioning.  相似文献   

15.
We have constructed a life-sized fully three-dimensional (3D) rigid flow-through model of the cerebral vasculature. Average vessel diameters and lengths, taken from published values in the literature, were used to describe the geometry of our phantom; numerically controlled machining techniques were used to fabricate the model. Inflow to the phantom is provided through two internal carotid arteries and two vertebral arteries. Outflow is provided through the anterior cerebral arteries, the middle cerebral arteries, and the posterior cerebral arteries. The phantom includes the circle of Willis, and aneurysms of variable size may be attached at different locations. We have tested the model for geometric accuracy using high-resolution MR and CT imaging protocols, and have found that measured and prescribed diameters agree to within better than 4%. Flow dynamics, including waveform shape and flow division between branches, also mimic that seen in vivo, with flows within 16% (on average) of the prescribed values. We present 3D magnetic resonance angiography, digital subtraction angiography, and computed rotational angiography images of the phantom under conditions that mimic physiological situations.  相似文献   

16.
Xu T  Ducote JL  Wong JT  Molloi S 《Medical physics》2006,33(6):1612-1622
The feasibility of a real-time dual-energy imaging technique with dynamic filtration using a flat panel detector for quantifying coronary arterial calcium was evaluated. In this technique, the x-ray beam was switched at 15 Hz between 60 kVp and 120 kVp with the 120 kVp beam having an additional 0.8 mm silver filter. The performance of the dynamic filtration technique was compared with a static filtration technique (4 mm Al+0.2 mm Cu for both beams). The ability to quantify calcium mass was evaluated using calcified arterial vessel phantoms with 20-230 mg of hydroxylapatite. The vessel phantoms were imaged over a Lucite phantom and then an anthropomorphic chest phantom. The total thickness of Lucite phantom ranges from 13.5-26.5 cm to simulate patient thickness of 16-32 cm. The calcium mass was measured using a densitometric technique. The effective dose to patient was estimated from the measured entrance exposure. The effects of patient thickness on contrast-to-noise ratio (CNR), effective dose, and the precision of calcium mass quantification (i.e., the frame to frame variability) were studied. The effects of misregistration artifacts were also measured by shifting the vessel phantoms manually between low- and high-energy images. The results show that, with the same detector signal level, the dynamic filtration technique produced 70% higher calcium contrast-to-noise ratio with only 4% increase in patient dose as compared to the static filtration technique. At the same time, x-ray tube loading increased by 30% with dynamic filtration. The minimum detectability of calcium with anatomical background was measured to be 34 mg of hydroxyapatite. The precision in calcium mass measurement, determined from 16 repeated dual-energy images, ranges from 13 mg to 41 mg when the patient thickness increased from 16 to 32 cm. The CNR was found to decrease with the patient thickness linearly at a rate of (-7%/cm). The anatomic background produced measurement root-mean-square (RMS) errors of 13 mg and 18 mg when the vessel phantoms were imaged over a uniform (over the rib) and nonuniform (across the edge of rib) bone background, respectively. Misregistration artifacts due to motions of up to 1.0 mm between the low- and high-energy images introduce RMS error of less than 4.3 mg, which is much smaller than the frame to frame variability and the measurement error due to anatomic background. The effective dose ranged from 1.1 to 6.6 microSv for each dual-energy image, depending on patient thickness. The study shows that real-time dual-energy imaging can potentially be used as a low dose technique for quantifying coronary arterial calcium.  相似文献   

17.
Objective: To characterize the effect of vessel curvature on the geometric accuracy of conventional three-dimensional reconstruction (3DR) algorithms for intravascular ultrasound image data.Background: A common method of 3DR for intravascular ultrasound image data involves geometric reassembly and volumetric interpolation of a spatially related sequence of tomographic cross sections generated by an ultrasound catheter withdrawn at a constant rate through a vascular segment of interest. The resulting 3DR is displayed as a straight segment, with inherent vascular curvature neglected. Most vascular structures, however, are not straight but curved to some degree. For this reason, vascular curvature may influence the accuracy of computer-generated 3DR.Methods: We collected image data using three different intravascular ultrasound catheters (2.9 Fr, 4.3 Fr, 8.0 Fr) during a constant-rate pullback of 1 mm/sec through tubing of known diameter with imposed radii of curvature ranging from 2 to 10 cm. Image data were also collected from straight tubing. Image data were digitized at 1.0-mm intervals through a length of 25 mm. Two passes through each radius of curvature were performed with each intravascular ultrasound catheter. 3DR lumen volume for each radius of curvature was compared to that theoretically expected from a straight cylindrical segment. Differences between 3DR lumen volume of theoreticalversus curved (actual) tubes were quantified as absolute percentage error and categorized as a function of curvature. Tubing deformation error was quantified by quantitative coronary angiography (QCA).Results: Volumetric errors ranged from 1% to 35%, with an inverse relationship demonstrated between 3DR lumen volume and segmental radius of curvature. Higher curvatures (r<6.0 cm) induced greater lumen volume error when compared to lower curvatures (r>6.0 cm). This trend was exhibited for all three catheters and was shown to be independent of tubing deformation artifacts. QCA-determined percentage diameter stenosis indicated no deformation error as a function of curvature. Total volumetric error contributed by tubing deformation was estimated to be 0.05%.Conclusions: Catheter-dependent geometrical error arises in three-dimensionally reconstructed timed linear pullbacks of intravascular ultrasound images due in part to uniplanar vascular curvature. Three-dimensional reconstruction of timed linear pullbacks is robust for vessels with low radii of curvature; however, careful interpretation of three-dimensional reconstructions from timed linear pullbacks for higher radii of curvature is warranted. These data suggest that methods of spatially correct three-dimensional reconstruction of intravascularultrasound images should be considered when more pronounced vascular curvature is present.  相似文献   

18.
The quality of dosimetry in radiotherapy treatment requires the accurate delimitation of the gross tumor volume. This can be achieved by complementing the anatomical detail provided by CT images through fusion with other imaging modalities that provide additional metabolic and physiological information. Therefore, use of multiple imaging modalities for radiotherapy treatment planning requires an accurate image registration method. This work describes tests carried out on a Discovery LS positron emission/computed tomography (PET/CT) system by General Electric Medical Systems (GEMS), for its later use to obtain images to delimit the target in radiotherapy treatment. Several phantoms have been used to verify image correlation, in combination with fiducial markers, which were used as a system of external landmarks. We analyzed the geometrical accuracy of two different fusion methods with the images obtained with these phantoms. We first studied the fusion method used by the PET/CT system by GEMS (hardware fusion) on the basis that there is satisfactory coincidence between the reconstruction centers in CT and PET systems; and secondly the fiducial fusion, a registration method, by means of least-squares fitting algorithm of a landmark points system. The study concluded with the verification of the centroid position of some phantom components in both imaging modalities. Centroids were estimated through a calculation similar to center-of-mass, weighted by the value of the CT number and the uptake intensity in PET. The mean deviations found for the hardware fusion method were: deltax/ +/-sigma = 3.3 mm +/- 1.0 mm and /deltax/ +/-sigma = 3.6 mm +/- 1.0 mm. These values were substantially improved upon applying fiducial fusion based on external landmark points: /deltax/ +/-sigma = 0.7 mm +/- 0.8 mm and /deltax/ +/-sigma = 0.3 mm 1.7 mm. We also noted that differences found for each of the fusion methods were similar for both the axial and helical CT image acquisition protocols.  相似文献   

19.
A new technique of patient positioning for radiotherapy/radiosurgery of extracranial tumours using three-dimensional (3D) ultrasound images has been developed. The ultrasound probe position is tracked within the treatment room via infrared light emitting diodes (IRLEDs) attached to the probe. In order to retrieve the corresponding room position of the ultrasound image, we developed an initial ultrasound probe calibration technique for both 2D and 3D ultrasound systems. This technique is based on knowledge of points in both room and image coordinates. We first tested the performance of three algorithms in retrieving geometrical transformations using synthetic data with different noise levels. Closed form solution algorithms (singular value decomposition and Horn's quaternion algorithms) were shown to outperform the Hooke and Jeeves iterative algorithm in both speed and accuracy. Furthermore, these simulations show that for a random noise level of 2.5, 5, 7.5 and 10 mm, the number of points required for a transformation accuracy better than 1 mm is 25, 100, 200 and 500 points respectively. Finally, we verified the tracking accuracy of this system using a specially designed ultrasound phantom. Since ultrasound images have a high noise level, we designed an ultrasound phantom that provides a large number of points for the calibration. This tissue equivalent phantom is made of nylon wires, and its room position is optically tracked using IRLEDs. By obtaining multiple images through the nylon wires, the calibration technique uses an average of 300 points for 3D ultrasound volumes and 200 for 2D ultrasound images, and its stability is very good for both rotation (standard deviation: 0.4 degrees) and translation (standard deviation: 0.3 mm) transformations. After this initial calibration procedure, the position of any voxel in the ultrasound image volume can be determined in world space, thereby allowing real-time image guidance of therapeutic procedures. Finally, the overall tracking accuracy of our 3D ultrasound image-guided positioning system was measured to be on average 0.2 mm, 0.9 mm and 0.6 mm for the AP, lateral and axial directions respectively.  相似文献   

20.
The feasibility of air-coupled ultrasound transducers to detect laser-induced ultrasound from artificial blood vessels embedded in an optically scattering phantom is demonstrated. These air-coupled transducers allow new applications in biomedical photoacoustic imaging where contact with tissue is not preferred. One promising application of such transducers is the addition of photoacoustic imaging to the regular x-ray mammographic screening procedure.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号