首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Treatment of Acute Aortic Type B Dissection with Stent-Grafts   总被引:3,自引:0,他引:3  
Purpose: To evaluate the feasibility of endoluminal stent-grafts in the treatment of acute type B aortic dissections. Methods: In five patients with acute aortic type B dissections, sealing of the primary intimal tear with an endoluminal stent-graft was attempted. Indication for treatment was aneurysm formation in two patients and persistent pain in three patients. One of the latter also had an unstable dissection flap compromising the ostium of the superior mesenteric artery. The distance from the intimal tear to the left subclavian artery was <0.5 cm in four patients, who had typical type B dissections. In one patient with an atypical dissection the distance from the primary tear to the left subclavian artery was 4 cm. This patient had no re-entry tear. Talent tube grafts (World Medical Manufacturing Cooperation, Sunrise, FL, USA) were used in all patients. Results: Stent-graft insertion with sealing of the primary tear was successful in all patients. The proximal covered portion of the stent-graft was placed across the left subclavian artery in four patients (1× transposition of the left subclavian artery). Left arm perfusion was preserved via a subclavian steal phenomenon in the patients in whom the stent-graft covered the orifice of the left subclavian artery. The only procedural complication we observed was an asymptomatic segmental renal infarction in one patient. In the thoracic aorta thrombosis of the false aortic lumen occurred in all patients. In one patient the false lumen of the abdominal aorta thrombosed after 4 weeks; in the other three patients the status of the abdominal aorta remained unchanged compared with the situation prior to stent-graft insertion. As a late complication formation of a secondary aneurysm of the thoracic aorta was observed at the distal end of the stent-graft 3 months after the primary intervention. This aneurysm was treated by coaxial insertion of an additional stent-graft without complications. Conclusion: Endoluminal treatment of acute type B aortic dissections seems to be an attractive alternative treatment to surgical repair. Thrombosis of the false lumen of the thoracic aorta can be induced if the primary tear is sealed with a stent-graft. This could protect the dissected thoracic aorta from delayed rupture.  相似文献   

2.
A 54-year-old man with persistent chest pain was hospitalized for hypertension and DeBakey type IIIb aortic dissection. The false lumen of the dissection was almost completely thrombosed; however, a penetrating atherosclerotic ulcer (PAU) was observed 5 weeks later. At that time, we successfully embolized the PAU with a microcatheter and interlocking detachable coils (IDCs). The patient is well with no episodes of relapse in 20 months of follow-up. This case suggests the utility of the microcatheter and IDC system as an alternative to surgery.  相似文献   

3.
Purpose: Suboptimal distal coronary flow reserve after successful balloon angioplasty has been attributed to angiographically unrecognized inadequate lumen expansion, and adjunct coronary stenting has been shown to improve coronary flow reserve. The aim of this study was to investigate whether myocardial fractional flow reserve (FFRmyo) would increase further after coronary stenting compared with balloon angioplasty alone in the same patient group. Methods: FFRmyo and quantitative coronary angiography were obtained before and after pre-stent balloon dilation, and again after stent placement in 11 patients (7 left anterior descending artery, 3 right coronary artery and 1 left circumflex artery). FFRmyo was calculated as the ratio of Pd/Pa during intracoronary adenosine 5′-triphosphate (50 μg and 20 μg in the left and right coronary arteries, respectively)-induced maximum hyperemia, where Pd represents mean distal coronary pressure measured by a 2.1 Fr infusion catheter and Pa represents mean aortic pressure measured by the guiding catheter. Results: Percent diameter stenosis significantly decreased after balloon angioplasty (74% ± 15% vs 37% ± 17%, p < 0.001), and decreased further after stent placement (18% ± 10%, p < 0.001 vs baseline and balloon angioplasty). FFRmyo after coronary stenting (0.85 ± 0.09) was significantly higher than that at baseline (0.51 ± 0.16, p < 0.001) and after balloon angioplasty (0.77 ± 0.11, p < 0.05). There was a significant correlation between angiographic variables and FFRmyo. The increase in lumen dimensions after coronary stenting was followed by a further significant improvement of FFRmyo. Conclusion: These results suggest that coronary stenting may provide a more favorable functional status and lumen geometry of residual coronary stenosis compared with balloon angioplasty alone.  相似文献   

4.
Purpose: To evaluate the efficacy of primary stenting for complex atherosclerotic plaques in aortic and iliac stenoses that are not amenable to balloon angioplasty alone. Methods: Nineteen patients with complex atherosclerotic plaques were treated with a Palmaz stent (n= 19), Wallstent (n= 1), Strecker stent (n= 1), or Memotherm stent (n= 1). A total of 22 stenoses presenting with complex plaque morphology including ulcerated plaques, ulcerated plaques with focal aneurysms, plaques with heavy calcification, severely eccentric plaques, plaques with overhanging edge, and plaques with spontaneous dissection were stented. The lesions were in the aorta (n= 1), common iliac artery (n= 19), or external iliac artery (n= 2). Results: Immediate angiography after stent placement revealed restoration of patency of the stented segment. Focal aneurysms and ulcerated areas were occluded in the follow-up angiographies obtained 4–12 weeks after the procedure. In one case with poor distal runoff and multiple complex lesions of the iliac artery, subacute occlusion occurred. Clinical and angiographic follow-up (3–46 months) revealed patency of all other stented segments. Conclusion: Primary stenting is an effective and reliable approach for complex plaques in stenoses. Patency of the arterial segment with a smooth lumen can be created without the risk of acute complications such as distal embolization, dissection, or occlusion.  相似文献   

5.
Purpose: To compare patency and neointima formation of single and tandem arterial stents. Methods: In each of six sheep, two Memotherm nitinol stents (tandem stents) were inserted into the external iliac artery on one side and a single stent into the artery on the opposite side. The size of the iliac lumen was assessed in the proximal, middle, and distal segments of the stents by intravascular ultrasound (IVUS) before, immediately after, and 1 month after implantation when the sheep were killed. Neointimal thickness was determined in the proximal, middle, and distal segments of each stent by light microscopy. Results: All stents remained patent. There was no significant difference in lumen and neointimal thickness between single and tandem stents. Cranial tandem stents showed a significantly wider lumen and smaller neointimal thickness than caudal tandem stents. In the proximal and distal segments, the lumen of the stents was significantly smaller and the neointimal thickness greater than in the middle segment; differences in neointimal thickness were significant only between the proximal and the middle segment. Conclusion: In an experimental setting, tandem stents did not interfere with one another with regard to patency and neointima formation when compared with a single contralateral stent. Neointimal thickening after stent insertion seems to be inversely related to the original arterial diameter.  相似文献   

6.
Purpose: To compare angiographic and intravascular ultrasound (IVUS) data before and after balloon angioplasty (PTA) of the femoropopliteal artery. Methods: Qualitative and quantitative analyses were performed on corresponding angiographic and IVUS levels obtained from 135 patients. Results: IVUS detected more lesions, calcified lesions, and vascular damage than angiography. Sensitivity of angiography was good for the presence of a lesion (84%), moderate for eccentric lesions (53%) and for vascular damage (52%), and poor for calcified lesions (30%). The increase in angiographic diameter stenosis was associated with a decrease in lumen area and increase in percentage area stenosis on IVUS. Conclusions: Angiography is less sensitive than IVUS for detecting lesion eccentricity, calcified lesions, and vascular damage. Presence of a lesion and amount of plaque were underestimated angiographically. Only before PTA was good agreement found between angiographic diameter stenosis and lumen size on IVUS.  相似文献   

7.
Bronchial artery dilatation and aneurysm formation is a potential complication of local inflammation, especially in bronchiectasis. When the bronchial artery has an ectopic origin from the inferior segment of the aortic arch, aneurysms may mimick aortic aneurysms. Despite this particular location, endovascular treatment is possible. We report two such aneurysms that were successfully embolized with steel coils.  相似文献   

8.
Purpose: To describe the efficacy and value of endovascular stent-grafts for the treatment of aortic anastomotic pseudoaneurysms. Methods: Three patients with proximal aortic anastomotic pseudoaneurysms 8–15 years after prosthetic reconstruction were treated by transfemoral stent-graft implantation. In two patients the pseudoaneurysms were excluded by Talent prostheses [tube graft (n = 1), bifurcated graft (n = 1)]. In one patient an uniiliac Zenith stent-graft was implanted and an extra-anatomic crossover bypass for revascularization of the contralateral lower extremity was performed. Results: All procedures were successful with primary exclusion of the pseudoaneurysms. During the follow-up (mean 16 months) one endoleak occurred due to migration of the tube stent-graft. The endoleak was sealed successfully by implanting an additional bifurcated stent-graft. Conclusion: Stent-graft exclusion of aortic pseudoaneurysms offers a minimally invasive and safe alternative to open surgical reconstruction.  相似文献   

9.
We implanted stents in three patients who had traumatic abdominal aortic dissections, complicated by right limb ischemia in one case. The circulating false channel extended to the left iliac artery in one case and to both iliac arteries in the last case. Diagnosis and radiological follow-up included ultrasound, computed tomography, and arteriography. Two patients were treated with Wallstents, one with a Palmaz stent. The occlusion of the false channel was obtained in all patients without any significant residual stenosis. No early or late complication was noted in any of the patients. The longest follow-up was 2 years. We conclude that stent placement is an efficient method for the treatment of noniatrogenic inframesenteric aortic dissections. Received: 0/00/00/Accepted: 0/00/00  相似文献   

10.
Purpose: Polymer-coated, dexamethasone (DXM)-releasing stents were tested in order to assess the efficacy of DXM released locally for the prevention of stent restenosis due to intimal hyperplasia. Methods: Strecker stents coated with a biodegradable membrane containing DXM were implanted percutaneously into the femoral artery in 14 dogs. The contralateral artery received a conventional non-coated stent serving as control. The drugs are eluted by degradation of the carrier membrane. Follow-up intraarterial digital subtraction angiography (DSA) was obtained at 3, 6, 9, 12, and 24 weeks with subsequent autopsy. Specimens for gross and microscopic pathology were obtained and histomorphometry was performed. Results: Four of 14 DXM-coated stents showed thrombotic occlusion within the first 3 weeks; ten DXM-coated stents remained patent. At follow-up DSA, DXM-coated stents showed a significantly wider lumen than the non-coated stents. At morphometry there was less intimal hyperplasia over DXM-coated stents than over non-coated stents (p < 0.05). Conclusion: DXM-coated stents reduce neointimal hyperplasia in dogs when compared with non-coated stents.  相似文献   

11.
Purpose: To evaluate efficacy of small intestinal submucosa (SIS) Sandwich endografts for the treatment of acute rupture of abdominal aortic aneurysms (AAA) and to explore the short-term reaction of the aorta to this material. Methods: In eight adult sheep, an infrarenal AAA was created transluminally by dilation of a short Palmaz stent. In six sheep, the aneurysm was then ruptured by overdilation of the stent with a large angioplasty balloon. Two sheep with AAAs that were not ruptured served as controls. A SIS Sandwich endograft, consisting of a Z stent frame with 5 bodies and covered inside and out with SIS, was used to exclude the ruptured and non-ruptured AAAs. Follow-up aortography was done immediately after the procedure and before sacrifice at 4, 8, or 12 weeks. Autopsy and histologic studies followed. Results: Endograft placement was successful in all eight sheep. Both ruptured and non-ruptured AAAs were successfully excluded. Three animals with AAA rupture developed hind leg paralysis due to compromise of the arterial supply to the lower spinal cord and were sacrificed 1 day after the procedure. In five animals, three with rupture and two controls, follow-up aortograms revealed no aortic stenoses and no perigraft leaks. Gross and histologic studies revealed incorporation of the endografts into the aortic wall with replacement of SIS by dense neointima that was completely endothelialized in areas where the endograft was in direct contact with the aortic wall. In central portions of the endograft, in contact with the thrombosed aneurysm, endothelialization was incomplete even at 12 weeks. Conclusion: The SIS Sandwich endografts effectively excluded simple AAAs and ruptured AAAs. They were rapidly incorporated into the aortic wall. A detailed long-term study is warranted.  相似文献   

12.
Purpose: To investigate whether a correlation exists between aortic and renal arterial calcifications detected with spiral CT and significant angiographic renal artery stenosis (RAS). Methods: Forty-two patients (mean age 67 years, range 37–84 years), of whom 24 were hypertensive, prospectively underwent abdominal helical CT and aortic and renal arteriography. The 3-mm thickness CT scans (pitch = 1) were reconstructed each millimeter. A manual outline of the renal artery including its ostial portion was produced. Calcific hyperdensities were defined as areas of density more than 130 HU. CT data were compared with the presence or absence of RAS on angiography (24 cases); hypertension and age were taken into account (Mann-Whitney U-test). Results: CT detection and quantification appeared to be reliable and reproductible. We did not find any correlation between aortic and renal arterial calcifications and RAS, even for the patients above 65 years, with or without hypertension. There was no correlation either between calcifications and hypertension in patients without RAS. Conclusion: In this population, aortic and renal arterial calcifications have no predictive value for RAS.  相似文献   

13.
Purpose: Intravascular ultrasound (IVUS) was used to assess in vitro the morphologic and quantitative effects of balloon angioplasty (PTA) of the iliac artery. Methods: Forty human iliac arteries (≥ 30% area stenosis) were studied with IVUS in vitro before and after PTA and the findings were validated with histology. Results: The sensitivity of IVUS for dissection was 74% and for media rupture 59%. The incidence of vascular damage was higher when the whole segment was analyzed rather than the target site alone. Dissections occurred at the thinnest region of the plaque, unrelated to plaque calcification. Following PTA, quantitative changes at the target site were greater compared with the overall data derived from all cross-sections. The increase in lumen area was caused solely by an increase in vessel area. Conclusions: IVUS is sensitive in detecting dissections, which occurred irrespective of calcification at the thinnest region of the plaque. The increase in lumen area after PTA was caused by stretching of the vessel.  相似文献   

14.
A three-dimensional model was constructed from helical CT images for abdominal aortic aneurysm (AAA) and thoracic aortic aneurysm (TAA). A stent-graft was designed and positioned endoluminally on the computer. One hundred and nine stent-grafts for 101 patients were designed by this method and deployed well in all patients. The design time was reduced from 4 to 0.5 hr.  相似文献   

15.
A 74-year-old male claudicant who had a significant abdominal aortic stenosis was hydrated before aortic stent placement because of an elevated creatinine level. During the intervention the patient experienced acute abdominal pain with vomiting. No vascular cause was detected. Due to persistant pain, plain radiography and an abdominal CT scan were performed a few hours after the procedure. Images revealed a bilateral renal fornix rupture with a large retroperitoneal fluid collection. The patient was treated conservatively with ureteral double-J placement and percutaneous nephrostomy. The further course was uneventful and the patient was discharged 2 weeks later free of symptoms. Renal fornix rupture is a very rare complication after contrast medium application that can be treated without surgery.  相似文献   

16.
We evaluated the vascular territory of accessory renal arteries in cases where the vessel might be overlapped by an aortic stent-graft. Spiral CT during selective accessory renal artery angiography was performed in four patients with abdominal aortic aneurysms (including one with a horseshoe kidney). The volume of the vascular territory of each renal artery was measured using a software program provided by the CT unit manufacturer. The supernumerary renal arteries perfused 32%, 37%, 15%, and 16% of the total renal mass, respectively. In two patients, stent-grafts were implanted, which resulted in occlusion of the supernumerary renal artery. The volume of the renal infarction was equal to the volume perfused by the artery as calculated before implantation of the stent-graft. The method proposed is accurate for estimating the size of the expected renal infarction. It might help to determine whether placement of a stent-graft is acceptable.  相似文献   

17.
Purpose: To evaluate the effects of bare stents and covered stents on the aortic wall, especially the vasa vasorum. Methods: Eight bare stents and nine covered stents were placed in the infrarenal aorta of nine dogs. The dogs were euthanized at 4–45 weeks after stent placement. The vasa vasorum was evaluated by microstereoscopy with vascular casting, and the histopathology of the aortic wall was examined by light microscopy. Results: In the unstented normal aorta, vasa vasorum nourished the adventitia and the outer media, and the intima and inner media were avascular. In the stented segment, vascular dilatation and proliferation of vasa vasorum, medial atrophy, and intimal hyperplasia were observed, more prominent for covered stents than for bare stents. Conclusion: Intravascular stent placement caused not only medial atrophy and intimal hyperplasia but also proliferation of the vasa vasorum, probably due to hypoxia in the aortic wall. Received: 0/00/00/Accepted: 0/00/00  相似文献   

18.
We successfully stabilized severe hemorrhagic shock following traumatic liver injury by percutaneous transcarotid supraceliac aortic occlusion with a 5 Fr balloon catheter. Then we were able to perform transfemoral embolization therapy of the hepatic arterial bleeding source. Transient aortic occlusion using a balloon catheter appears to be a useful adjunct in select cases where stabilization of the patient is necessary to allow successful selective embolization of the bleeding source.  相似文献   

19.
This report describes an in-stent restenosis of the infrarenal aorta in a patient with Takayasu's arteritis in a nonactive state. A 10-mm-diameter Wallstent had been deployed 42 months previously. The stented restenosed segment was replaced by a surgical graft. Histopathological examination of the excised aortic segment showed a thin layer of fibrocellular neointima and massive organized and calcified thrombus. To our knowledge, this is the first histopathological report of a late in-stent restenosis of the abdominal aorta in Takayasu's arteritis. RID=" ID=" <E5>Correspondence to:</E5> H. Ishibashi-Ueda, M.D.  相似文献   

20.
Purpose: To investigate the incidence, significance, and mechanism of stent-graft distortion after endovascular repair (EVR) of abdominal aortic aneurysm. Methods: EVR of abdominal aortic aneurysm was performed in 51 cases (49 modular, bifurcated; 2 tube). Thirty-two patients were followed for 6 or more months and had equivalent baseline and follow-up images which could be used to determine changes in graft configuration. Sac dimensions were measured using computed tomographic (CT) images and graft-related complications were recorded. Results: Amongst 32 patients evaluated on follow-up, there was graft distortion in 24. Distorted grafts were significantly (p= 0.002) associated with sac diameter reduction (mean 5 mm) and sac length reduction (mean 8.1 mm). All graft-related complications occurred in the limbs of eight distorted grafts, with a mean reduction of sac length in this group of 7.8 mm on reformatted CT images. Conclusion: There was a highly significant association between graft distortion and limb complications, and reduced sac dimensions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号