首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
准分子激光原位角膜磨镶术治疗超高度近视远期疗效分析   总被引:16,自引:0,他引:16  
Li DZ  Xu XM  Zhou SL  Fu JS 《中华眼科杂志》2004,40(12):816-818
目的探讨准分子激光原位角膜磨镶术(LASIK)治疗超高度(等效球镜度数>-10.00 D)近视的远期效果和安全性.方法对99例(173只眼)超高度近视行LASIK矫正,术前屈光度数-10.00~-23.50 D,平均(-13.7±3.6)D(等效球镜),其中-15.00 D以上41只眼.常规行裂隙灯显微镜、三面镜眼底检查、OrbscanⅡ眼前段分析系统、眼压、A超、角膜测厚、电脑验光、散瞳检影、主观验光等检查.术后随访18个月以上.结果术后18个月时裸眼视力≥0.5者148只眼(85.6%),最佳矫正视力高于或等于术前最佳矫正视力者147只眼(84.4%),未见术后最佳矫正视力较术前最佳矫正视力低于2行以上的眼;屈光度数稳定在±1.00 D以下者109只眼(63.0%),术前屈光度数在-14.75 D以下和-15.00 D以上达到±1.00 D内者的百分数分别为73.5%(97只眼/132只眼)和29.3%(12只眼/41只眼).术后角膜后表面前移,术后3个月时后表面顶点距理想球面的距离为(0.069±0.031)mm,18个月为(0.065±0.025)mm,均大于术前的(0.029±0.010)mm;角膜微皱褶2只眼,诉暗视力下降眩光6例(10只眼).结论 LASIK矫正超高度近视有效安全,同时在选择手术适应证方面应谨慎从之.对于屈光度数太高而角膜厚度偏薄者行LASIK应慎重,可考虑其他方法矫正如晶状体屈光手术或联合手术.(中华眼科杂志,2004,40816-818)  相似文献   

2.
PURPOSE: To compare the visual and refractive outcomes of laser in situ keratomileusis (LASIK) and laser-assisted subepithelial keratectomy (LASEK) in the treatment of high myopia. SETTING: Institute of Vision Research, Department of Ophthalmology, College of Medicine, Yonsei University, and Balgeunsesang Ophthalmology Clinic, Seoul, South Korea. METHODS: Four hundred seventy eyes of 240 patients with manifest refraction spherical components greater than -6.00 diopters (D) were assigned to 2 groups: 324 eyes (167 patients) were treated with LASIK and 146 eyes (73 patients), with LASEK. Uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), remaining refractive error, corneal haze, and complications were followed in both groups for 12 months. RESULTS: At 12 months, the mean spherical equivalent (SE) was within +/-0.50 D of emmetropia in 205 eyes (63.3%) in the LASIK group and 81 eyes (55.5%) in the LASEK group and within +/-1.00 D in 261 eyes (80.6%) and 104 eyes (71.2%), respectively. The UCVA was 20/25 or better in 269 LASIK eyes (83.0%) and 111 LASEK eyes (76.0%). There was more than a 1-line loss of BSCVA in 4 LASIK eyes (1.2%) and 21 LASEK eyes (14.3%). The between-group differences in SE, magnitude of cylinder, UCVA, and haze were statistically significant (P<.05). CONCLUSIONS: Both LASIK and LASEK were safe and effectively treated eyes with high myopia. Laser in situ keratomileusis provided superior results in visual predictability and corneal opacity.  相似文献   

3.
PURPOSE: To evaluate the clinical results of wavefront-guided laser in situ keratomileusis (LASIK) with the Zyoptix system. METHODS: Twelve patients (24 eyes) underwent wavefront-guided LASIK with the Bausch & Lomb Zyoptix system. Uncorrected and best spectacle-corrected visual acuity and manifest refraction were measured at postoperative day 1, week 1, and months 1 and 3. A subjective vision quality questionnaire evaluated light sensitivity, dryness, tearing, glare, halos, ghost images, and difficulties in night driving, preoperatively and 3 months postoperatively. RESULTS: Preoperatively, mean sphere was -3.70 +/- 2.33 D (range -0.50 to -8.00 D), mean cylinder was -0.90 +/- 0.98 D (range 0 to -3.00 D), and mean spherical equivalent refraction was -4.15 +/- 2.16 D (range -1.38 to -8.25 D). Three-month postoperative spherical equivalent refraction was within +/- 0.50 D of emmetropia in 17 eyes (70.8%) and within +/- 1.00 D in 22 eyes (91.7%). At 3 months postoperatively, no eyes lost any lines of BSCVA and eight eyes (33.3%) gained 2 lines. The ratio of postoperative BSCVA to preoperative BSCVA (safety) was 1.05 +/- 0.09 (range 1.00 to 1.20) at 1 month and 1.07 +/- 0.10 (range 1.00 to 1.29) at 3 months. The ratio of postoperative UCVA to preoperative BSCVA (efficacy) was 0.96 +/- 0.12 (range 0.80 to 1.20) at 1 month and 0.95 +/- 0.12 (range 0.8 to 1.2) at 3 months. The subjective vision quality questionnaire revealed less tearing, fewer halos, and less difficulty in night driving after wavefront-guided LASIK. Comparison of higher order optical aberrations before and after surgery was not done. CONCLUSIONS: Wavefront-guided LASIK with the Bausch & Lomb Zyoptix system was safe and effective in correcting low to moderate myopic refractive error.  相似文献   

4.
PURPOSE: To evaluate the visual and refractive results of laser in situ keratomileusis (LASIK) for mixed and simple myopic astigmatism using bitoric ablation. METHODS: A retrospective study was performed in 65 eyes of 38 consecutive patients to evaluate uncorrected (UCVA) and best spectacle-corrected visual acuity (BSCVA) and cyclopegic and manifest refraction, before and 3 and 6 months after LASIK (Moria LSK-ONE microkeratome, Nidek EC-5000 excimer laser). RESULTS: At 3 and 6 months after LASIK, 40 eyes of 24 patients (64.5%) were available for follow-up examination. Mean age was 25.9 +/- 6.6 years (range 18 to 43 yr). Mean preoperative manifest spherical equivalent refraction was -1.40 +/- 0.80 D (range -3.80 to +0.50 D) mean preoperative cylinder was -3.30 +/- 1.30 D (range -1.00 to -6.00 D). At 6 months follow-up, mean manifest spherical equivalent refraction was +0.30 +/- 0.46 D (range -0.38 to +1.88 D), mean cylinder was -0.73 +/- 0.61 D (range -2.25 to 0 D). There was a 77.8% decrease in astigmatism magnitude. According to vector analysis, mean achieved vector magnitude was 80% of intended. Fifty percent (20 eyes) had a cylinder within +/- 0.50 D of emmetropia. Twenty-three eyes (57.5%) had a spherical component within +/- 0.50 D. Eighty-five percent (34 eyes) had postoperative UCVA of 20/40 or better. Ten percent (four eyes) lost two lines of Snellen BSCVA, whereas 35% (14 eyes) gained one or more lines. CONCLUSIONS: Bitoric LASIK with the Moria LSK-ONE microkeratome and Nidek EC-5000 excimer laser was effective and safe for the reduction of cylinder in mixed and simple myopic astigmatism. Moderate undercorrection of the cylinder was evident.  相似文献   

5.
PURPOSE: To evaluate the visual and refractive results of laser in situ keratomileusis (LASIK) retreatment on eyes with residual myopia with or without astigmatism. METHODS: LASIK retreatment was performed on 35 eyes of 23 patients for correction of residual myopia, with or without astigmatism, with a mean manifest spherical equivalent refraction of -2.17+/-0.82 D (range, -1.00 to -3.87 D) and mean refractive astigmatism of -0.55+/-0.61 D (range, 0 to -1.75 D). Retreatment was performed 3 to 18 months after primary LASIK (mean, 5.1+/-2.6 mo). The corneal flap of the previous LASIK was lifted and laser ablation was performed using the Chiron-Technolas Keracor 116 excimer laser. Follow-up was 12 months for all eyes. RESULTS: At 1 year after retreatment, manifest spherical equivalent refraction was reduced to a mean -0.23+/-0.28 D (range, 0 to -0.87 D), and refractive astigmatism was reduced to a mean -0.16+/-0.25 D (range, 0 to -0.75 D). Thirty-two eyes (91.5%) had a manifest spherical equivalent refraction within +/-0.50 D of emmetropia, and 33 eyes (94.3%) had 0 to 0.50 D of refractive astigmatism. Uncorrected visual acuity was 20/20 or better in 11 eyes (31.4%). Spectacle-corrected visual acuity was not reduced in any eye after retreatment. There were no significant complications. CONCLUSION: LASIK retreatment was effective for correction of residual myopia or astigmatism after primary LASIK. Refractive results were predictable with good stability after 3 months. Lifting the flap during LASIK retreatment was relatively easy to perform and did not result in visual morbidity in eyes treated from 3 up to 18 months after primary LASIK.  相似文献   

6.
PURPOSE: To evaluate the safety and efficacy of laser in situ keratomileusis (LASIK) for correction of myopia in eyes with previous retinal detachment surgery. METHODS: A retrospective review was conducted of all consecutive eyes that underwent LASIK after retinal detachment surgery. Data was collected regarding previous ocular surgery and its time prior to LASIK, intra- and postoperative complications, and visual outcome measures pre- and postoperatively. RESULTS: Ten eyes with previous retinal detachment surgery were scheduled for LASIK. One eye was excluded from data analysis as LASIK was aborted due to inadequate microkeratome suction because of conjunctival scarring. Nine eyes underwent an uneventful LASIK procedure. On average, LASIK was performed 130+/-123 months following retinal detachment surgery. Postoperative LASIK follow-up was 14.8+/-12.5 months. No significant intraoperative, postoperative, or retinal complications were observed. The mean preoperative spherical equivalent refraction was -9.00+/-3.00 diopters (D), uncorrected visual acuity (UCVA) was 0.06+/-0.02, and best spectacle-corrected visual acuity (BSCVA) was 0.64+/-0.16. At the end of follow-up, the mean spherical equivalent refraction was 0.65+/-0.88 D, mean UCVA was 0.57+/-0.14, and mean BSCVA was 0.72+/-0.19. Differences between BSCVA before and after LASIK were statistically significant (P=.038). At final follow-up, the safety index was 1.22 and efficacy index was 1.01. CONCLUSIONS: Laser in situ keratomileusis was found to be a safe and efficient option for treating refractive errors in eyes with previous retinal detachment surgery.  相似文献   

7.
PURPOSE: To analyze the results of hyperopic patients treated with a peripheral presbyLASIK algorithm for the correction of presbyopia. METHODS: The study included 44 eyes of 22 hyperopic patients treated with a peripheral presbyLASIK technique using a Technolas 217z excimer laser. Mean patient age was 56 years (range: 47 to 72 years), mean preoperative spherical equivalent refraction was +1.21 +/- 0.77 diopters (D) (range: +0.50 to +4.00 D), and mean spectacle near addition was +1.76 +/- 0.42 D (range: +1.00 to +2.75 D). The Peripheral Multifocal LASIK (PML) ablation pattern creates a multifocal corneal profile over a 6.5-mm diameter, performing the distance correction first in a 6-mm optical zone and then near correction in a 6.5-mm zone. Main outcome measures were uncorrected visual acuity (UCVA) and best spectacle-corrected visual acuity (BSCVA) for near and distance, spherical equivalent refraction, contrast sensitivity, and corneal aberrations. RESULTS: Six months postoperatively, mean binocular UCVA was 1.06 +/- 0.13 for distance and 0.84 +/- 0.14 for near. Mean postoperative spherical equivalent refraction was -0.42 D (range: -1.12 to +0.87 D). Two (4.5%) eyes lost 1 line of BSCVA for distance and near vision, and 20 (45%) eyes gained 1 line of distance BSCVA. Contrast sensitivity decreased for 3, 6, 12, and 18 cycles/degree. Corneal aberration analysis showed a slight increase in coma and decrease in spherical aberration. CONCLUSIONS: The peripheral presbyLASIK technique used in this study is a safe and efficient treatment that may improve functional near vision in presbyopic patients with low and moderate hyperopia (from +0.50 to +3.00 D).  相似文献   

8.
PURPOSE: To evaluate the safety and efficacy of superficial laser ablation on the flap as a treatment for residual ametropia after laser in situ keratomileusis (LASIK). SETTING: Private practice refractive surgery center, Utrecht, The Netherlands. METHODS: This retrospective study comprised 18 eyes of 15 patients who had alcohol-assisted photorefractive keratectomy (PRK) or laser-assisted subepithelial keratectomy (LASEK) retreatment for residual ametropia after LASIK. All patients who had retreatment on the flap between June 2004 and June 2005 were included in the study. Retreatments were performed by wavefront-guided excimer laser surface ablation using the Visx Star S4 laser. Outcome measures included uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), subjective refraction, and biomicroscopy at the 3-, 6-, and 12-month postoperative visits. RESULTS: The preoperative spherical equivalent (SE) refraction was -0.63 diopter (D) +/- 0.87 (SD) (range -2.00 to +1.38 D). The mean amount of ablated cornea was 21.3 +/- 7.4 microm. At 3 months, the mean UCVA was 0.83 +/- 1.5 lines (range 0.40 to 1.25), yielding an efficacy index of 0.87. At 6 months, the mean UCVA increased to 0.98 +/- 0.8 line (range 0.63 to 1.25) and the efficacy index, to 1.03. At 12 months, 6 eyes were lost to follow-up. The mean UCVA was 0.83 +/- 2.2 lines (range 0.20 to 1.25), with an efficacy index of 0.87. The mean BSCVA was 0.98 +/- 0.9 line (range 0.80 to 1.25) at 3 months and 1.05 +/- 0.6 line (range 0.80 to 1.25) at 6 months, yielding a safety index of 1.03 and 1.11, respectively. At 12 months, the mean BSCVA was 0.95 +/- 1.0 line (range 0.63 to 1.25), with a safety index of 1.0. At 6 months, no eye had lost lines of BSCVA, 11 eyes had no change, and 7 eyes gained 1 line. At 12 months, 2 eyes lost 1 line of BSCVA, 8 eyes had no change, and 2 eyes gained 1 line. The mean SE refraction was +0.10 +/- 0.27 D (range -0.25 to +0.63 D) at 3 months, +0.06 +/- 0.37 D (range -0.50 to +1.13 D) at 6 months, and +0.15 +/- 0.39 D (range -0.50 to +0.88 D) at 12 months. On biomicroscopic examination, 1 eye had prolonged grade 1 haze that disappeared before 6 months. Two eyes of 1 patient who had hyperopic retreatment developed late-onset haze 8 months postoperatively. Eyes with microstriae in the flap before retreatment showed significant improvement after retreatment. There were no sight-threatening complications. CONCLUSION: Wavefront-guided LASEK or alcohol-assisted PRK retreatment on the surface of a LASIK flap was safe and effective in correcting small amounts of residual myopia.  相似文献   

9.
PURPOSE: To assess the use of the femtosecond laser for laser in situ keratomileusis (LASIK) in eyes with consecutive hyperopia after radial keratotomy (RK). SETTING: Private ambulatory surgical center, Valencia, Spain. METHODS: This prospective noncomparative interventional case series study included 13 eyes of 9 patients with secondary hyperopia after previous RK. The patients were operated on with the IntraLase femtosecond laser (IntraLase Corp.) and the Star S2 excimer laser (Visx, Inc.). Postoperative uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), manifest refraction, flap thickness, flap diameter, and complications were evaluated at 6 months. RESULTS: The mean spherical equivalent (SE) decreased from 2.00 diopters (D)+/-0.40 (SD) to -0.41+/-0.61 D, with 8 eyes (61.5%) within+/-0.50 D of the targeted refraction. Twelve eyes (92.3%) had a UCVA of 20/40 or better, and 3 eyes (23.1%) lost 1 line of BSCVA. A mean change in SE of 0.10 D was observed at the 6-month follow-up. The mean flap thickness and diameter were 117+/-14 microm and 9.18+/-0.12 mm, respectively. Most complications were in eyes with more than 8 RK incisions than in eyes with 8 RK incisions. These complications were multiple intraoperative incision openings (100% versus 28.6%, respectively), interface inflammation (66.6% versus 0%, respectively), haze (83.3% versus 14.3%, respectively), and loss of BSCVA (50% versus 0%, respectively). CONCLUSIONS: The femtosecond laser provided large, thin corneal flaps for hyperopic LASIK. However, the procedure should be avoided in eyes with more than 8 RK incisions because of the increased risk for multiple intraoperative incision openings, interface inflammation, haze, and loss of BSCVA.  相似文献   

10.
PURPOSE: To compare laser epithelial keratomileusis (LASEK) and LASIK for the correction of high myopia. METHODS: A prospective, single-masked study was conducted. Patients treated with LASEK to correct myopia > or = -7.00 diopters (D) (spherical equivalent manifest refraction) with a cylinder < or = -3.50 D (LASEK group) were compared to patients treated with LASIK (LASIK group) using the same excimer laser (Technolas 217C). Mitomycin C (MMC) 0.02% was applied for 1 minute in all LASEK-treated eyes. RESULTS: A total of 228 consecutive eyes were included in the study (114 in each group, matched for preoperative refraction). The mean preoperative spherical equivalent manifest refraction was -8.72 +/- 1.20 D in the LASEK group and -8.74 +/- 1.20 D in the LASIK group (range: -7.00 to -13.75 D) (P = .9). Uncorrected visual acuity (UCVA) was significantly lower in LASEK eyes 1, 7, and 30 days postoperatively (P = .0001 for each comparison). No significant differences were found at 3 months postoperatively in UCVA (P = .3), best spectacle-corrected visual acuity (BSCVA) (P = .2), or in the safety (P = .6) and efficacy (P = .8) indices. Uncorrected visual acuity was 1.0 or better in 34.2% of LASEK eyes and 44.7% of LASIK eyes. Spherical refraction was +0.25 +/- 0.6 D after LASEK and -0.06 +/- 0.5 D after LASIK (P = .0001). Sixty-eight percent of LASEK eyes and 79% of LASIK eyes were within +/- 0.50 D of intended refraction. No LASEK eye versus 7 LASIK eyes lost 2 lines of BSCVA. Eight LASEK eyes gained 2 or more lines of BSCVA versus 1 LASIK eye. CONCLUSIONS: Visual improvement after LASEK with intraoperative MMC was significantly slower than after LASIK. Visual outcomes (UCVA, BSCVA, and safety and efficacy indices) 3 months after surgery were similar with both techniques for the correction of high myopia. Ten percent more eyes after LASIK were within +/- 0.50 D of intended refraction.  相似文献   

11.
PURPOSE: To evaluate and compare the visual and clinical outcomes of wavefront-guided laser in situ keratomileusis (LASIK) with the Alcon CustomCornea (Alcon Laboratories Inc, Fort Worth, Tex) and VISX CustomVue (VISX, Santa Clara, Calif) systems. METHODS: Ninety-three eyes of 56 patients (50 and 43 consecutive eyes on CustomCornea and CustomVue, respectively) were enrolled in a prospective multisurgeon clinical outcome study. Uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), and manifest refraction were measured at 1 day, 1 week, 1 month, and 3 months postoperatively. Early treatment diabetic retinopathy study (ETDRS) visual acuity and contrast sensitivity were measured at 1 month and 3 months, and wavefront mapping at 3 months. RESULTS: Preoperatively, the CustomCornea group had a mean sphere of -3.90 +/- 1.62 diopters (D) (range -0.50 to -7.25 D), mean cylinder of +0.62 +/- 0.39 D (range 0 to +1.50 D), and mean manifest spherical equivalent refraction of -3.59 +/- 1.54 D. The CustomVue group had a sphere of -3.87 +/- 1.45 D (range -1.75 to -6.75 D), cylinder of +0.49 +/- 0.36 D (range 0 to +1.50 D), and manifest spherical equivalent refraction of -3.62 +/- 1.46 D. At 3 months, 98% of the CustomCornea group and 95% of the CustomVue group were within +/-0.50 D. Ninety-nine percent of eyes did not change >0.50 D (manifest spherical equivalent refraction) between 1 month and 3 months. CustomCornea eyes improved on contrast sensitivity testing and had a better profile than CustomVue for 20/15 Snellen and 20/12.5 ETDRS acuity. Both laser groups had a decrease in higher order aberrations with statistical significance for coma and spherical aberration in the CustomCornea group. CONCLUSION: Wavefront-guided LASIK with both systems is safe and effective.  相似文献   

12.
LASIK in children with hyperopic anisometropic amblyopia   总被引:1,自引:0,他引:1  
PURPOSE: To evaluate the results of LASIK for hyperopia in pediatric eyes with amblyopia resulting from anisometropia. METHODS: Thirty-two children with anisometropic amblyopia in whom conventional therapy was unsuccessful underwent unilateral LASIK between 1999 and 2005. Mean patient age was 10.3 +/- 3.1 years (range: 4 to 15 years), and mean follow-up was 20.1 +/- 15.1 months (range: 12 to 60 months). At the last follow-up examination, spherical equivalent refraction, uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), and complications were recorded. RESULTS: Mean preoperative and postoperative manifest spherical equivalent refraction of the treated eyes was 5.17 +/- 1.65 and 1.39 +/- 1.21 diopters (D), respectively (P < .01). Mean UCVA was 0.06 +/- 0.09 (range: 0.01 to 0.5) preoperatively and 0.27 +/- 0.23 (range: 0.05 to 0.8) postoperatively (P < .01). Mean BSCVA was 0.20 +/- 0.17 (range: 0.01 to 0.8) preoperatively and 0.35 +/- 0.25 (range: 0.1 to 1.0) postoperatively (P < .01). Six eyes gained > or = 4 lines of BSCVA, 4 eyes gained 2 to 3 lines, 12 eyes gained 1 line, and 9 eyes were unchanged; only 1 eye lost 1 line of BSCVA due to haze in the flap-stroma interface. None of the patients reported halos or glare. There were no intraoperative or postoperative flap complications. CONCLUSIONS: LASIK seems to be an effective and safe procedure for the management of hyperopic anisometropic amblyopia in select cases. Visual acuity improved in the amblyopic eyes and was associated with decreased anisometropia. The refractive response to hyperopic LASIK in children appears to be similar to that of adults with comparable refractive errors.  相似文献   

13.
PURPOSE: To evaluate safety, predictability, efficiency, and long-term stability of laser in situ keratomileusis (LASIK) for spherical hyperopia. METHODS: This study was a retrospective 5-year analysis of 67 patients (125 eyes) who had LASIK for spherical hyperopia; preoperative mean manifest spherical equivalent refraction was +3.84+/-1.13 D (range +1.00 to +6.50 D) and mean astigmatism was 0.37+/-0.27 D (range 0 to 1.00 D). Preoperative spherical equivalent refraction for the low hyperopia group was +1.00 to +2.75 D; medium hyperopia group, +3.00 to +4.25 D, and high hyperopia group, +4.50 to +6.50 D. All surgeries were performed using the scanning Chiron Technolas Keracor 117C excimer laser. Uncorrected and best spectacle-corrected visual acuity, predictability, long-term stability of refraction, and complications were analyzed. RESULTS: At 5 years after hyperopic LASIK, mean spherical equivalent refraction for the low hyperopia group was +0.48D+/-0.79 D; medium hyperopia group, +1.52+/-1.45 D; high hyperopia group C, +3.39+/-1.98 D. The percentage of eyes with a spherical equivalent refraction within +/-0.50 D of emmetropia for the low hyperopia group was 63% (37 eyes); medium hyperopia group, 42% (20 eyes); high hyperopia group, 22% (4 eyes). Eyes with chronic dry eye symptoms had a mean difference in spherical equivalent refraction from target refraction of +1.43 D compared with +0.84 D for eyes without dry eye symptoms. Five eyes (4%) lost 2 lines of BSCVA at 5 years. CONCLUSION: LASIK was safe, effective, and stable for primary hyperopia between +1.00 and +3.00 D. Higher amounts of hyperopia had poor long-term stability, especially eyes with more than +4.25 D. Chronic dry eye symptoms were associated with regression over time.  相似文献   

14.
PURPOSE: To describe the preoperative characteristics, intraoperative details, management, and postoperative in patients with bilateral epithelial defects after laser in situ keratomileusis (LASIK). METHODS: Retrospective non-comparative case series. RESULTS: Six patients with bilateral epithelial defects after LASIK were part of a cohort of 605 patients undergoing bilateral LASIK at our center from December 2001 to April 2003. The mean age of the patients (5M:1F) was 28.5 +/- 7.9 years, and the average pretreatment myopic spherical equivalent (SE) refraction was 7.3 +/- 0.7 D (-4, -12.25D). An epithelial flap was present in 6 eyes and an epithelial defect with a mean diameter of 3 mm (2mm, 6mm) was seen in 6 eyes. In four patients the epithelial disturbance was bilaterally similar. All defects occurred in the inferior cornea and the epithelial flaps had the hinge positioned superiorly. None of the patients had ocular or systemic risk factors that could have resulted in this complication. A bandage contact lens was used in 6 eyes. At last follow-up of 5.5 +/- 9.5 months (0.25, 21 months), unaided visual acuity was 6/9 or better in 10 eyes. Best spectacle-corrected visual acuity (BSCVA) was maintained in 8 eyes, while 4 eyes lost one line of BSCVA. Recurrent corneal erosions were not reported in the follow-up period. CONCLUSIONS: These patients represent a hitherto unrecognised group of individuals who appear to have a subclinical weakness of adhesion of the corneal epithelium to the underlying structures, which is not evident on clinical examination. This results in bilateral epithelial disturbances after LASIK. Appropriate management results in satisfactory clinical outcomes. Other options for treatment of the fellow eye of such patients include the use of a different microkeratome, release of suction during the reverse pass of the Hansatome microkeratome, and photorefractive keratectomy if the refractive error is low.  相似文献   

15.
PURPOSE: To compare the results of photorefractive keratectomy (PRK) and laser in situ keratomileusis (LASIK) over a 4-year follow-up. SETTING: Miyata Eye Hospital, Miyazaki, Japan. METHODS: This comparative retrospective study comprised 22 eyes (22 patients) that had PRK and 18 eyes (18 patients) that had LASIK. To be included, the patient had to have completed a 4-year follow-up. Uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), percentage of eyes within +/-0.5 diopter (D) of the targeted refraction, central corneal thickness, and the anterior and posterior corneal elevations were compared between the PRK and LASIK groups. RESULTS: The mean UCVA was significantly better in the LASIK group than in the PRK group at 6 months (P = .0043) and 1 year (P = .0044). At 2 years, there was no significant difference in the mean UCVA between the 2 groups. The mean BSCVA was significantly better in the LASIK group than in the PRK group at 6 months (P<.0001), 1 year (P<.0001), and 2 years (P = .0083). At 3 and 4 years, there was no significant difference in the mean BSCVA between the 2 groups. The percentage of eyes within +/-0.5 D of the targeted refraction was not significantly different between groups at any time. CONCLUSIONS: The superiority of LASIK over PRK in short-term efficacy was not retained 4 years after surgery. The main reasons were a myopic shift and a decline in UCVA at the last follow-up in the LASIK group.  相似文献   

16.
Flap measurements with the Hansatome microkeratome   总被引:1,自引:0,他引:1  
PURPOSE: To evaluate flap thickness, flap diameter, and hinge length during laser in situ keratomileusis (LASIK) and to correlate these measurements with preoperative keratometric power, central corneal thickness, and patient refraction, gender, and age. METHODS: In this prospective study of 50 eyes of 28 patients (mean age 31 +/- 6.6 yr; range, 24 to 43 yr) results of LASIK for myopia were analyzed (mean spherical equivalent refraction of -7.16 +/- 1.69 D; range, -2.75 to -13.50 D). Corneal flaps were created using the Hansatome microkeratome (Baush & Lomb Surgical) with a 160-microm plate and a 9.5-mm suction ring. Corneal thickness was evaluated using an ultrasonic 50-MHz pachymeter (Sonogage Corneo Gage Plus) and the mean keratometric power was measured with a Corneal Analysis System videokeratographic unit (EyeSys). Data were analyzed using t-test, Pearson product moment correlation coefficient, and Spearman's rho non-parametric correlation coefficients. RESULTS: Mean corneal flap thickness was 142.6 +/- 20.8 microm (range, 107 to 177 microm), mean flap diameter was 9.9 +/- 0.3 mm (range, 9.2 to 10.5 mm), and mean hinge length was 6.2 +/- 0.4 mm (range, 5.2 to 7 mm). Statistically significant correlations (P<.05) were found between mean keratometric power and flap hinge length, mean keratometric power and flap diameter, preoperative spherical equivalent refraction and flap diameter, corneal thickness and flap hinge length, as well as patient age and corneal thickness. CONCLUSIONS: The Hansatome microkeratome was an effective and safe instrument in the creation of corneal flaps for LASIK. Consideration of preoperative keratometric power and corneal thickness may help to reduce or avoid complications.  相似文献   

17.
PURPOSE: To determine the safety, efficacy, predictability, and stability of laser in situ keratomileusis (LASIK) in treating patients with myopic astigmatism using the Meditec MEL 70 G-Scan excimer laser. METHODS: Seventy-four eyes of 42 patients with myopia ranging from -4.50 to -9.88 D and astigmatism ranging from 0.50 to 4.00 D who underwent LASIK with the Meditec MEL 70 G-Scan excimer laser and the Summit Krumeich-Barraquer microkeratome were studied. Patients were followed for 1 year. RESULTS: Mean baseline spherical equivalent refraction was -7.12 +/- 1.70 D and cylinder was 1.62 +/- 1.72 D. At 12 months, mean postoperative spherical equivalent refraction was -0.49 +/- 0.57 D and mean refractive cylinder was 0.59 +/- 0.32 D. Mean change in spherical equivalent refraction between 1 and 12 months after surgery was -0.09 +/- 0.31 D, toward myopia. At baseline, no eyes had best spectacle-corrected visual acuity (BSCVA) of 20/20 or better, and 65% had 20/40 or better. At 12 months after surgery, 10% of eyes had BSCVA of 20/20 or better and 88% of eyes had 20/40 or better. The unusually low postoperative BSCVA results were thought to be due to amblyopia or existence of a higher percentage of some optical aberrations in this group of eyes. Mean uncorrected visual acuity was -1.38 +/- 0.42 LogMAR units (20/400) at baseline and -0.29 +/- 0.25 LogMAR units (20/40) at the 12-month postoperative examination. No eyes lost two or more lines of spectacle-corrected visual acuity. No vision threatening complications were observed. CONCLUSIONS: LASIK with the Meditec MEL 70 G-Scan excimer laser appeared to be safe, effective, reasonably predictable, and stable for correction of myopic astigmatism with a spherical component between -4.25 and -8.25 D and a cylindrical component between 0.50 and 4.00 D. However, astigmatism was slightly undercorrected with the algorithm used.  相似文献   

18.
PURPOSE: To evaluate excimer laser in situ keratomileusis (LASIK) for the correction of hyperopia. METHODS: We reviewed retrospectively the medical records of 46 patients treated with LASIK for hyperopia. All patients had a complete ophthalmologic evaluation. The corneal bed was ablated using the Bausch & Lomb Chiron Keracor 117C excimer laser to create a paracentral annular ablation under a nasally hinged 160-microm corneal flap with the Chiron Automatic Corneal Shaper microkeratome. Follow-up was a minimum of 6 months. RESULTS: Eighty eyes of 46 patients (23 males and 23 females) were included. Age ranged from 18 to 65 years (mean, 42 yr). The range of preoperative spherical equivalent refraction was +0.50 to +11.50 D (mean, +3.40 D). Mean postoperative spherical equivalent refraction at 6 months was +0.26 D. Six months after surgery, 35 eyes (44%) achieved uncorrected visual acuity of 20/20 or better and 78 eyes (97.5%) achieved 20/40 or better. Forty-six eyes (58%) had a postoperative spherical equivalent refraction within +/-0.50 D of attempted correction, and 67 eyes (84%) were within +/-1.00 D of attempted correction. When using the Bausch & Lomb Chiron Keracor 117C excimer laser to correct hyperopia, eyes with a spherical equivalent refraction less +2.00 D should be overcorrected by 25%, +2.00 to +4.00 D by 30%, and over +4.00 by 40%. The positive cylinder should be overcorrected by 10%. CONCLUSIONS: LASIK was safe and effective in the treatment of hyperopia from +0.50 to +11.50 D. Regression following LASIK for hyperopia remains a problem. A special nomogram was required to achieve results comparable with those for myopia.  相似文献   

19.
PURPOSE: To investigate the anatomic variations of entrance pupil decentration and tilting angle of the iris in healthy subjects and the influence of these factors on the outcome of laser in situ keratomileusis (LASIK). SETTING: Minamiaoyama Eye Clinic, Tokyo, Japan. METHODS: The degree of pupil decentration and tilting angle of the iris in 2280 eyes of 1144 myopic patients without abnormal findings by ophthalmologic examination were assessed using Orbscan. Of these, 901 eyes of 467 patients had LASIK. Multiple analysis of variance (ANOVA) was used to determine risk factors for reduction of postoperative best spectacle-corrected visual acuity (BSCVA) considering patient age, refractive power, tilting angle of the iris, pupil decentration, and corneal power. RESULTS: The mean pupil decentration in all eyes was 0.19 mm +/- 0.11 (SD) (range 0 to 0.9 mm); tilting angle of the iris was 4.06 +/- 1.41 degrees (range 0.19 to 12.69 degrees). By multiple ANOVA, refractive power, pupil decentration, and tilting angle of the iris were significant for the reduction of BSCVA. CONCLUSIONS: Some eyes with pupil decentration or tilting angle of the iris could not be detected under typical ophthalmologic examination but only with topographic examination. Attention should be paid to eyes with large pupil decentration and tilting angle of the iris because these may be risk factors for reduction of postoperative BSCVA during corneal refractive surgeries.  相似文献   

20.
PURPOSE: To evaluate the efficacy, predictability, and safety of wavefront-guided laser in situ keratomileusis (LASIK) using the Visx CustomVue excimer laser (Advanced Medical Optics) in eyes with consecutive hyperopia and compound hyperopic astigmatism after LASIK. SETTING: Stanford University School of Medicine, Department of Ophthalmology, Stanford, California, USA. METHODS: This retrospective analysis included 19 eyes of 16 patients who had wavefront-guided LASIK for consecutive hyperopia and compound hyperopic astigmatism after initial LASIK surgery. Primary outcome variables, including uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), higher-order aberration (HOA) analysis, and spherical equivalence, were evaluated at 1 and 3 months. Nine eyes of 7 patients were available for all visits. RESULTS: The mean patient age was 51.7 years +/- 3.77 (SD) (range 44 to 55 years). The mean preoperative manifest refractive spherical equivalent (MRSE) was 0.99 +/- 0.32 diopters (D) (range 0.50 to 1.50 D) and the mean 3-month postoperative MRSE, -0.04 +/- 0.66 D (range -1.50 to 0.75 D). At 1 month, 57.9% of eyes had a UCVA of 20/20 or better and 78.9% of 20/25 or better; 84.2% were within +/-1.00 D of emmetropia. At 3 months, 66.7% of eyes had a UCVA of 20/20 or better and 88.9% of 20/25 or better; 88.9% were within +/-1.00 D of emmetropia. No eye lost 2 or more lines of BSCVA at 1 or 3 months. CONCLUSION: Wavefront-guided LASIK was an effective, predictable, and safe procedure for consecutive hyperopia and compound hyperopic astigmatism after LASIK.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号