首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A comparative kinematics study was conducted on six cadaver limbs, comparing tibiofemoral kinematics in five conditions: unloaded, under a constant 130 N ankle load with a variable quadriceps load, with and without a simultaneous constant 50 N medial and lateral hamstrings load. Kinematics were described as translation of the projected centers of the medial (MFT) and lateral femoral condyles (LFT) in the horizontal plane of the tibia, and tibial axial rotation (TR) as a function of flexion angle. In passive conditions, the tibia rotated internally with increasing flexion to an average of −16° (range: −12/−20°, SD = 3.0°). Between 0 and 40° flexion, the medial condyle translated forwards 4 mm (range: 0.8/5.5 mm, SD = 2.5 mm), followed by a gradual posterior translation, totaling −9 mm (range: −5.8/−18.5 mm, SD = 4.9 mm) between 40–140° flexion. The lateral femoral condyle translated posteriorly with increasing flexion completing −25 mm (range: −22.6 to −28.2 mm, SD = 2.5 mm). Dynamic, loaded measurements simulating a deep knee bend were carried out in a knee rig. Under a fixed ankle load of 130 N and variable quadriceps loading, tibial rotation was inverted, mean TR = 4.7° (range: −3.3°/11.8° SD = 5.4°), MFT = −0.5 mm (range: = −4.3/2.4 mm, SD = 2.4 mm), LFT = 3.3 mm (range: = −3.6/10.6 mm, SD = 5.1 mm). Compared to the passive condition, all these excursions were significantly different (p ≤ 0.015). Adding medial and lateral hamstrings force of 50 N each reduced TR, MFT, and LFT significantly compared to the passive condition. In general, loading the knee with hamstrings and quadriceps reduces rotation and translation compared to the passive condition. Lateral hamstring action is more influential on knee kinematics than medial hamstrings action. © 2009 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 28:419–428, 2010  相似文献   

2.
Altered patellofemoral joint contact pressures are thought to contribute to patellofemoral joint symptoms. However, little is known about the relationship between tibiofemoral joint kinematics and patellofemoral joint contact pressures. The objective of this paper was to investigate the effect of tibiofemoral joint kinematics on patellofemoral joint pressures using an established in vitro robotic testing experimental setup. Eight cadaveric knee specimens were tested at 0 degrees, 30 degrees, 60 degrees, 90 degrees, and 120 degrees of flexion under an isolated quadriceps load of 400 N and a combined quadriceps/hamstrings load of 400 N/200 N. Tibiofemoral joint kinematics were measured by the robot and contact pressures by a TekScan pressure sensor. The isolated quadriceps loading caused anterior translation and internal rotation of the tibia up to 60 degrees of flexion and posterior translation and external rotation of the tibia beyond 60 degrees. The co-contraction of the hamstring muscles caused a posterior translation and external rotation of the tibia relative to the motion of the tibia under the quadriceps load. Correspondingly, the contact pressures were elevated significantly at all flexion angles. For example, at 60 degrees of flexion, the hamstrings co-contraction increased the posterior tibial translation by approximately 2.8 mm and external tibial rotation by approximately 3.6 degrees. The peak contact pressure increased from 1.4+/-0.8 to 1.7+/-1.0 MPa, a 15% increase. The elevated contact pressures after hamstrings co-contraction indicates an intrinsic relation between the tibiofemoral joint kinematics and the patellofemoral joint biomechanics. An increase in posterior tibial translation and external rotation is accompanied by an increase in contact pressure in the patellofemoral joint. These results imply that excessive strength conditioning with the hamstring muscles might not be beneficial to the patellofemoral joint. Knee pathology that causes an increase in tibial posterior translation and external rotation might contribute to degeneration of the patellofemoral joint. These results suggest that conservative treatment of posterior cruciate ligament injury should be reconsidered.  相似文献   

3.
Strengthening of the hamstrings is often recommended following injury and reconstruction of the anterior cruciate ligament. It has been suggested that hamstrings activity stabilizes the knee and reduces anterior cruciate ligament load during weight-bearing flexion; however, the effects of hamstrings cocontraction on the kinematics and mechanics of the normal knee have not been assessed at physiological load levels. The aim of this study was to determine whether the addition of hamstrings force affects knee rotations, translations, and joint and quadriceps force during flexion with loads at physiological levels applied to the muscles and joints. Eight cadaveric knee specimens were tested with a servohydraulic mechanism capable of applying controlled dynamic loads to simulate quadriceps and hamstrings muscle forces throughout a physiological range of motion. A constant vertical load of physiologic magnitude was applied to the hip, and quadriceps force was varied to maintain equilibrium throughout flexion. Two conditions were tested: no hamstrings force and a constant hamstrings force equivalent to the vertical load. Hamstrings force significantly reduced internal rotation (p<0.0001) and anterior translation (p<0.0001), increased quadriceps force (p<0.0001) and normal resultant force on the tibia (p<0.0001), and reversed the direction of the shear force on the tibia (p<0.0001). These results suggest that hamstrings strengthening following anterior cruciate ligament injury may benefit anterior cruciate ligament-deficient and reconstructed knees by reducing the load in the ligament; however, they also imply that this comes at the expense of efficiency and higher patellofemoral and joint forces.  相似文献   

4.
Background The anterior cruciate ligament (ACL) constrains the anterior translation and axial rotation of the tibia. However, the effect of ACL injury on the mediolateral translation and varus-valgus rotation of the tibia is unknown. Because of the oblique orientation of the ACL, we hypothesized that ACL deficiency alters mediolateral translation and varus-valgus rotation.

Methods The kinematics of 9 cadavers from full extension to 90° of flexion under various loading conditions were measured before and after ACL resection using a robotic testing system.

Results ACL deficiency increased the medial translation of the tibia and valgus rotation, especially at 15° and 30° of flexion. For example, at 15°, ACL deficiency increased the medial translation from 1.2 (SD 0.9) mm to 1.8 (SD 1.1) mm in response to a quadriceps load. The valgus rotation also increased from 0.8° (SD 0.6) to 1.7° (SD 0.8).

Interpretation ACL deficiency altered both the mediolateral tibial translation and valgus-varus rotation under various loading conditions. The increased medial tibial translation could shift the contact in the medial compartment towards the medial tibial spine, a region where degeneration is observed in ACL-deficient patients. In addition to restoring anterior laxity, ACL reconstruction might need to restore the mediolateral translation of the tibia and varus-valgus rotation of the knee.  相似文献   

5.
Many clinical studies have emphasized the role of the hamstrings and the iliotibial band on knee mechanics, although few biomechanical studies have investigated it. This study therefore examined two hypotheses: (a) with loading of the hamstrings, the tibia translates posteriorly and rotates externally and the tibial contact pattern shifts anteriorly; furthermore, the changes in tibial kinematics alter patellar kinematics and contact; and (b) loading the iliotibial band alters the kinematics and contact pattern of the tibiofemoral joint similarly to loading the hamstrings, and loading the iliotibial band laterally translates the patella and its contact location. Five cadaveric knee specimens were tested with a specially designed knee-joint testing machine in an open-chain configuration. At various flexion angles, the knees were tested always with a quadriceps force but with and without a hamstrings force and with and without an iliotibial band force. The results support the first hypothesis. Hence, the hamstrings may be important anterior and rotational stabilizers of the tibia, a role similar to that of the anterior cruciate ligament. The results also support the second hypothesis, although the iliotibial band force had a smaller effect on the tibia than did the hamstrings force. Both forces also changed patellar kinematics and contact, demonstrating that these structures should also be considered during the clinical management of patellar disorders.  相似文献   

6.
The objectives of this study were to determine the effects of hamstrings and quadriceps muscle loads on knee kinematics and in situ forces in the posterior cruciate ligament of the knee and to evaluate how the effects of these muscle loads change with knee flexion. Nine human cadaveric knees were studied with a robotic manipulator/universal force-moment sensor testing system. The knees were subjected to an isolated hamstrings load (40 N to both the biceps and the semimembranosus), a combined hamstrings and quadriceps load (the hamstrings load and a 200-N quadriceps load), and an isolated quadriceps load of 200 N. Each load was applied with the knee at full extension and at 30, 60, 90, and 120 degrees of flexion. Without muscle loads, in situ forces in the posterior cruciate ligament were small, ranging from 6+/-5 N at 30 degrees of flexion to 15+/-3 N at 90 degrees. Under an isolated hamstrings load, the in situ force in the posterior cruciate ligament increased significantly throughout all angles of knee flexion, from 13+/-6 N at full extension to 86+/-19 N at 90 degrees. A posterior tibial translation ranging from 1.3+/-0.6 to 2.5+/-0.5 mm was also observed from full extension to 30 degrees of flexion under the hamstrings load. With a combined hamstrings and quadriceps load, tibial translation was 2.2+/-0.7 mm posteriorly at 120 degrees of flexion ut was as high as 4.6+/-1.7 mm anteriorly at 30 degrees. The in situ force in the posterior cruciate ligament decreased significantly under this loading condition compared with under an isolated hamstrings load, ranging from 6+/-7 to 58+/-13 N from 30 to 120 degrees of flexion. With an isolated quadriceps load of 200 N, the in situ forces in the posterior cruciate ligament ranged from 4+/-3 N at 60 degrees of flexion to 34+/-12 N at 120 degrees. Our findings support the notion that, compared with an isolated hamstrings load, combined hamstrings and quadriceps loads significantly reduce the in situ force in the posterior cruciate ligament. These data are in direct contrast to those for the anterior cruciate ligament. Furthermore, we have demonstrated that the effects of muscle loads depend significantly on the angle of knee flexion.  相似文献   

7.
Accurate knowledge of knee joint motion is needed to evaluate the effects of implant design on functional performance and component wear. We conducted a randomized controlled trial to measure and compare 6-degree-of-freedom (6-DOF) kinematics and femoral condylar motion of posterior-stabilized (PS), cruciate-retaining (CR), and medial-stabilized (MS) knee implant designs for one cycle of walking. A mobile biplane X-ray imaging system was used to accurately measure 6-DOF tibiofemoral motion as patients implanted with PS (n = 23), CR (n = 25), or MS (n = 26) knees walked over ground at their self-selected speeds. Knee flexion angle did not differ significantly between the three designs. Relative movements of the femoral and tibial components were generally similar for PS and CR with significant differences observed only for anterior tibial drawer. Knee kinematic profiles measured for MS were appreciably different: external rotation and abduction of the tibia were increased while peak-to-peak anterior drawer was significantly reduced for MS compared with PS and CR. Anterior-posterior drawer and medial-lateral shift of the tibia were strongly coupled to internal-external rotation for MS, as was anterior-posterior translation of the contact center in the lateral compartment. MS exhibited the least amount of paradoxical anterior translation of the femur relative to the tibia during knee flexion. The joint center of rotation in the transverse plane was located in the lateral compartment for PS and CR and in the medial compartment for MS. Substantial differences were evident in 6-DOF knee kinematics between the healthy knee and all three prosthetic designs. Overall, knee kinematic profiles observed for MS resemble those of the healthy joint more closely than PS and CR.  相似文献   

8.
Application of axial tibial force to the knee at a fixed flexion angle has been shown to generate ACL force. However, direct measurements of ACL force under an applied axial tibial force have not been reported during a passive flexion–extension cycle. We hypothesized that ACL forces and knee kinematics during knee extension would be significantly different than those during knee flexion, and that ACL removal would significantly increase all kinematic measurements. A 500 N axial tibial force was applied to intact knees during knee flexion–extension between 0° and 50°. Contact force on the sloping lateral tibial plateau produced a coupled internal + valgus rotation of the tibia, anterior tibial displacement, and elevated ACL forces. ACL forces during knee extension were significantly greater than those during knee flexion between 5° and 50°. During knee extension, ACL removal significantly increased anterior tibial displacement between 0° and 50°, valgus rotation between 5° and 50°, and internal tibial rotation between 5° and 15°. With the ACL removed, kinematic measurements during knee extension were significantly greater than those during knee flexion between 5° and 45°. The direction of knee flexion–extension movement is an important variable in determining ACL forces and knee kinematics produced by axial tibial force. © 2013 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 32:89–95, 2014.  相似文献   

9.
Total knee arthroplasty (TKA) is a widely accepted surgical procedure for the treatment of patients with end‐stage osteoarthritis (OA). However, the function of the knee is not always fully recovered after TKA. We used a dual fluoroscopic imaging system to evaluate the in vivo kinematics of the knee with medial compartment OA before and after a posterior cruciate ligament‐retaining TKA (PCR‐TKA) during weight‐bearing knee flexion, and compared the results to those of normal knees. The OA knees displayed similar internal/external tibial rotation to normal knees. However, the OA knees had less overall posterior femoral translation relative to the tibia between 0° and 105° flexion and more varus knee rotation between 0° and 45° flexion, than in the normal knees. Additionally, in the OA knees the femur was located more medially than in the normal knees, particularly between 30° and 60° flexion. After PCR‐TKA, the knee kinematics were not restored to normal. The overall internal tibial rotation and posterior femoral translation between 0° and 105° knee flexion were dramatically reduced. Additionally, PCR‐TKA introduced an abnormal anterior femoral translation during early knee flexion, and the femur was located lateral to the tibia throughout weight‐bearing flexion. The data help understand the biomechanical functions of the knee with medial compartment OA before and after contemporary PCR‐TKA. They may also be useful for improvement of future prostheses designs and surgical techniques in treatment of knees with end‐stage OA. © 2010 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 29:40–46, 2011  相似文献   

10.
The mechanism of chronic degeneration of the knee after posterior cruciate ligament (PCL) injury is still not clearly understood. While numerous biomechanical studies have been conducted to investigate the function of the PCL with regard to antero-posterior stability of the knee, little has been reported on its effect on the rotational stability of the knee. In this study, eight cadaveric human knee specimens were tested on a robotic testing system from full extension to 120 degrees of flexion with the PCL intact and with the PCL resected. The antero-posterior tibial translation and the internal-external tibial rotation were measured when the knee was subjected to various simulated muscle loads. Under a quadriceps load (400 N) and a combined quadriceps/hamstring load (400/200 N), the tibia moved anteriorly at low flexion angles (below 60 degrees). Resection of the PCL did not significantly alter anterior tibial translation. At high flexion angles (beyond 60 degrees), the tibia moved posteriorly and rotated externally under the muscle loads. PCL deficiency significantly increased the posterior tibial translation and external tibial rotation. The results of this study indicate that PCL deficiency not only changed tibial translation, but also tibial rotation. Therefore, only evaluating the tibial translation in the anteroposterior direction may not completely describe the effect of PCL deficiency on knee joint function. Furthermore, the increased external tibial rotations were further hypothesized to cause elevated patello-femoral joint contact pressures. These data may help explain the biomechanical factors causing long-term degenerative changes of the knee after PCL injury. By fully understanding the etiology of these changes, it may be possible to develop an optimal surgical treatment for PCL injury that is aimed at minimizing the long-term arthritic changes in the knee joint.  相似文献   

11.
BACKGROUND: An analysis of contemporary total knee arthroplasty reveals that, on the average, patients rarely flex the knee beyond 120 degrees. The biomechanical mechanisms that inhibit further flexion after total knee arthroplasty are unknown. The objective of the present study was to investigate the capability of a single design of a fixed-bearing, high-flexion posterior stabilized total knee arthroplasty system (LPS-Flex) to restore the range of flexion to that of the intact knee. METHODS: Thirteen cadaveric human knees were tested, with use of a robotic testing system, before and after total knee arthroplasty with the LPS-Flex prosthesis. The passive path and the kinematics under an isolated quadriceps force of 400 N, under an isolated hamstring force of 200 N, and with these forces combined were determined. Posterior femoral translation of the lateral and medial femoral condyles and tibial rotation were recorded from 0 degrees to 150 degrees of flexion. RESULTS: The medial and lateral condyles of the intact knee translated posteriorly from full extension to 150 degrees, reaching a mean peak (and standard deviation) of 22.9 +/- 11.3 mm and 31.9 +/- 12.5 mm, respectively, under the combined muscle forces. Following total knee arthroplasty, the amount of posterior femoral translation was lower than that observed in the intact knee. At 150 degrees, approximately 90% of the intact posterior femoral translation was recovered by the total knee replacement. Internal tibial rotation was observed for all knees throughout the range of motion. The cam-spine mechanism engaged at approximately 80 degrees and disengaged at 135 degrees. Despite the absence of cam-spine engagement, further posterior femoral translation occurred from 135 degrees to 150 degrees. CONCLUSIONS: The tibiofemoral articular geometry of the intact knee and the knee after total knee arthroplasty with use of the LPS-Flex design demonstrated similar kinematics at high flexion angles. The cam-spine mechanism enhanced posterior femoral translation only at the mid-range of flexion. The femoral component geometry of the LPS-Flex total knee prosthesis may improve posterior tibiofemoral articulation contact in high flexion angles.  相似文献   

12.
Ten fresh-frozen knees from cadavera were instrumented with a specially designed transducer that measures the force that the anterior cruciate ligament exerts on its tibial attachment. Specimens were subjected to tibial torque, anterior tibial force, and varus-valgus bending moment at selected angles of flexion of the knee ranging from 0 to 45 degrees. Section of the medial collateral ligament did not change the force generated in the anterior cruciate ligament by applied varus moment. When valgus moment was applied to the knee, force increased dramatically after section of the medial collateral ligament; the increases were greatest at 45 degrees of flexion. Section of the medial collateral ligament had variable effects on the force generated in the anterior cruciate ligament during internal rotation but dramatically increased that generated during external rotation; these increases were greatest at 45 degrees. Section of the medial collateral ligament increased mean total torsional laxity by 13 degrees (at 0 degrees of flexion) to 20 degrees (at 45 degrees of flexion). Application of an anteriorly directed force to the tibia of an intact knee increased the force generated in the anterior cruciate ligament; this increase was maximum near the mid-part of the range of tibial rotation and minimum with external rotation of the tibia. Section of the medial collateral ligament did not change the force generated in the anterior cruciate ligament by straight anterior tibial pull near the mid-part of the range of tibial rotation.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

13.
We studied the response of the normal and unstable knee to passive motion and anterior tibial displacement in the cat. 6 cats were anesthetized and the deep level of anesthesia was controlled by electroencephalograms. We recorded electric activity in the articular nerves (posterior PAN and medial MAN) and periarticular muscles (quadriceps and hamstring), while performing passive flexion, extension, internal and external rotation. We then produced anterior displacement of the tibia at 30° and 90° of flexion, as in the Lachman and the anterior drawer maneuvers. The anterior cruciate ligament was surgically sectioned and the same series of passive displacements was performed. We observed statistically significant increased activity in the MAN, the PAN and the quadriceps muscle during knee flexion, in the MAN during extension, and in the PAN and hamstring during external rotation with the knee 90° flexed. Anterior cruciate transection caused anterior displacement of the tibia during stress. This produced a significant increase in the MAN activity and a significant decrease in the hamstring electric activity at 30° and 90° of flexion, as in Lachman and anterior drawer maneuvers. We conclude that electric activity in the articular nerves and periarticular muscles, in response to passive motion and anterior tibial displacement, is altered in the cat's knee after anterior cruciate transection. This suggests that various patterns of periarticular muscle reaction in the anterior cruciate-deficient knee may be related to the unconscious perception of abnormal motion.  相似文献   

14.
The incidence of meniscal tears in the chronically anterior cruciate ligament-deficient knee is increased, particularly in the medial meniscus because it performs an important function in limiting knee motion. We evaluated the role of the medial meniscus in stabilizing the anterior cruciate ligament-deficient knee and hypothesized that the resultant force in the meniscus is significantly elevated in the anterior cruciate ligament-deficient knee. To test this hypothesis, we employed a robotic/universal force-moment sensor testing system to determine the increase in the resultant force in the human medial meniscus in response to an anterior tibial load following transection of the anterior cruciate ligament. We also measured changes in the kinematics of the knee in multiple degrees of freedom following medial meniscectomy in the anterior cruciate ligament-deficient knee. In response to a 134-N anterior tibial load, the resultant force in the medial meniscus of the anterior cruciate ligament-deficient knee increased significantly compared with that in the meniscus of the intact knee; it increased by a minimum of 10.1 N (52%) at full knee extension to a maximum of 50.2 N (197%) at 60 degrees of flexion. Medial meniscectomy in the anterior cruciate ligament-deficient knee also caused a significant increase in anterior tibial translation in response to the anterior tibial load, ranging from an increase of 2.2 mm at full knee extension to 5.8 mm at 60 degrees of flexion. Conversely, coupled internal tibial rotation in response to the load decreased significantly, ranging from a decrease of 2.5 degrees at 15 degrees of knee flexion to 4.7 degrees at 60 degrees of flexion. Our data confirm the hypothesis that the resultant force in the medial meniscus is significantly greater in the anterior cruciate ligament-deficient knee than in the intact knee when the knee is subjected to anterior tibial loads. This indicates that the demand on the medial meniscus in resisting anterior tibial loads is increased in the anterior cruciate ligament-deficient knee compared with in the intact knee, suggesting a mechanism for the increased incidence of medial meniscal tears observed in chronically anterior cruciate ligament-deficient patients. The large changes in kinematics due to medial meniscectomy in the anterior cruciate ligament-deficient knee confirm the important role of the medial meniscus in controlling knee stability. These findings suggest that the reduction of resultant force in the meniscus may be a further motive for reconstructing the anterior cruciate ligament, with the goal of preserving meniscal integrity.  相似文献   

15.
Eleven fresh frozen cadaveric knee specimens were mounted in a knee kinematics test device, and normal patellar movements were evaluated with use of an external device for direct measurement of patellar movements. The effects of four different measurement conditions were assessed through alteration of one condition and determination of its effect on patellar kinematics with the use of six specimens. The four conditions included (a) change of the measuring axis from an axis parallel to the central axis of the femur (femoral axis) to one parallel to the central axis of the tibia (tibial axis), (b) rotation of the femoral axis internally 6°, (c) change of the direction of the quadriceps force from parallel to the mechanical line of the lower extremity to a direction parallel to the femoral shaft, and (d) increase of the magnitude of the quadriceps force from 111 to 500 N. During knee flexion, the patella shifted laterally after a slight initial medial shift, tilted laterally from midflexion to 90°, and gradually rotated medially. The patellar shift relative to the tibial axis appeared to be more medial than the shift measured relative to the femoral axis; the discrepancy was caused by the valgus position of the tibia relative to the femur. Changing the rotational angle of the femoral axis artifically changed the patellar position. Varying the direction of the quadriceps within the narrow range and increasing the quadriceps force did not affect patellar movements. It is likely that the anatomic configuration of the patella allows the patella to seat in a stable configuration so that it resists moderate changes in the load and direction of the quadriceps. Tibial rotation exerted a major influence on patellar shift and tilt in the early phase of knee flexion: the patella rotated medially when the tibia was externally rotated and rotated laterally when the tibia was internally rotated. These results indicate that the patella may be unstable in the first phase of knee flexion when the tibia is rotated.  相似文献   

16.
The reasons for the higher frequency of anterior cruciate ligament injuries in women are largely conjecture. These injuries may result from direct contact or, more frequently, from no direct contact to the knee during activities that most athletes consider routine to their sport. This implies that there are intrinsic factors that lead to anterior cruciate ligament rupture. For the anterior cruciate ligament to tear, there must be excess anterior tibial translation or rotation of the femur on the tibia. In the former case, the tibia can move anteriorly during quadriceps activation that is not counterbalanced by hamstring activation. Patients describe their injury as occurring when landing, stopping, or when planting to change directions. The knee typically was near full extension. Mechanically, the angle of the patellar tendon and tibial shaft increases as the knee approaches full extension. This gives a mechanical advantage to the quadriceps. During cutting maneuvers, athletes tend to cut with a knee near extension (0 degree-20 degrees) when the quadriceps are active and the hamstrings are neither very active nor at a knee flexion angle that offers much of a mechanical advantage. In performing cutting and landing maneuvers, women tend to perform the activities more erect; that is, with their knee and hips closer to extension. One possible factor to help reduce the frequency of anterior cruciate ligament injuries in women may be in proper instruction for performing cutting and landing maneuvers which will lower their center of gravity thereby denying the quadriceps the opportunity to shift the tibia anteriorly.  相似文献   

17.
The anterior or posterior drawer force exerted on the tibia by the separate isometric contractions of the quadriceps or hamstrings at various angles of knee flexion was examined in 20 healthy males. A two-dimensional model was analyzed using roentgenographic films. In separate isometric contractions of the quadriceps, the mean value of the anterior drawer force was equivalent to 14% of the tension of the quadriceps at 5 degrees knee flexion. The value decreased with the increase in the angle of knee flexion. The mean angle at which the anterior drawer force became zero was 45.3 degrees +/- 12.5 degrees. When the angle was increased further, the posterior drawer force gradually increased. In separate isometric contractions of the hamstrings, the posterior drawer force was exerted at all angles of flexion. Thus, during the early stage of rehabilitation after the anterior cruciate ligament injury, the quadriceps exercise by isometric muscle contraction should be performed with the knee flexion at more than 70 degrees (mean +/- 1.96). Exercise of the hamstrings by isometric muscle contractions can be carried out regardless of flexion angle.  相似文献   

18.
This study was conducted to determine the effectiveness of the Lenox Hill knee brace in limiting anterior translation and external rotation of the tibia in reference to the femur in normal and ligament-deficient knees. Four fresh cadaver knees were fitted with Lenox Hill knee braces according to the manufacturer's guidelines. A computer-assisted testing apparatus was constructed that allowed each knee to be tested as a function of knee flexion angle, joint load, and soft tissue integrity. Each knee served as its own control. While 45 kg of anterior force was applied to the tibia of the anterior cruciate ligament deficient knees, the Lenox Hill knee brace was able to decrease anterior translation from an average of 10 mm, to 5.7 mm, at 30 degrees of flexion when no vertical load was present. This limiting effect was lost when the medial collateral ligament was sectioned in addition to the anterior cruciate ligament or when both the medial and the lateral collateral ligaments were sectioned along with the anterior cruciate ligament. When 20 Newton-meters (Nm) of torque was applied to the femurs at 30 degrees of flexion without vertical load, the Lenox Hill knee brace limited external rotation of the tibia in all tested categories. For intact knees at 30 degrees of flexion and no vertical load, the Lenox Hill knee brace decreased external rotation from 18 degrees to 10 degrees. In the anterior cruciate ligament-sectioned knees, external rotation was decreased from an average of 20.2 degrees to 16.1 degrees. In the knees with sectioned anterior cruciate and medial collateral ligaments, the average reduction was from 21.2 degrees to 15.4 degrees.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

19.
 目的 探讨固定平台后稳定型假体全膝关节置换(total knee arthroplasty,TKA)术后膝关节在负重屈膝下蹲时的运动学特征。方法 选取10名健康志愿者和10例固定平台后稳定型假体TKA术后患者。制作骨骼及膝关节假体三维模型,在持续X线透视下完成负重下蹲动作,膝关节屈曲度每增加15°截取一幅图像。通过荧光透视分析技术完成三维模型与二维图像的匹配,再现股骨与胫骨在屈膝过程中的空间位置,通过连续的图像分析比较正常与固定平台后稳定型假体TKA术后膝关节在负重下蹲时股骨内、外髁前后移动及胫骨内外旋转幅度。结果 负重下蹲时,正常膝关节平均屈曲136°,股骨内、外髁分别后移(7.3±1.2) mm和(19.3±3.1) mm,胫骨平均内旋23.8°±3.4°;TKA术后膝关节平均屈曲125°,股骨内、外髁分别后移(1.4±1.6) mm和(6.4±1.7) mm,胫骨平均内旋8.5°±3.4°。结论 固定平台后稳定型假体TKA术后膝关节运动与正常膝关节相似,均表现出股骨内、外髁后移及胫骨内旋运动,但幅度小于正常膝关节,且在屈膝过程中存在股骨矛盾性前移及胫骨外旋现象。  相似文献   

20.
Medial unicompartmental knee arthroplasty (UKA) is an accepted treatment for isolated medial osteoarthritis. However, using an improper thickness for the tibial component may contribute to early failure of the prosthesis or disease progression in the unreplaced lateral compartment. Little is known of the effect of insert thickness on both knee kinematics and ligament forces. Therefore, a computational model of the tibiofemoral joint was used to determine how non‐conforming, fixed bearing medial UKA affects tibiofemoral kinematics, and tension in the medial collateral ligament (MCL) and the anterior cruciate ligament (ACL) during passive knee flexion. Fixed bearing medial UKA could not maintain the medial pivoting that occurred in the intact knee from 0° to 30° of passive flexion. Abnormal anterior–posterior (AP) translations of the femoral condyles relative to the tibia delayed coupled internal tibial rotation, which occurred in the intact knee from 0° to 30° of flexion, but occurred from 30° to 90° of flexion following UKA. Increasing or decreasing tibial insert thickness following medial UKA also failed to restore the medial pivoting behavior of the intact knee despite modulating MCL and ACL forces. Reduced AP constraint in non‐conforming medial UKA relative to the intact knee leads to abnormal condylar translations regardless of insert thickness even with intact cruciate and collateral ligaments. This finding suggests that the conformity of the medial compartment as driven by the medial meniscus and articular morphology plays an important role in controlling AP condylar translations in the intact tibiofemoral joint during passive flexion. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1868–1875, 2018.
  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号