1.
Ventricular fibrillation (VF) has been induced at implantable cardioverter defibrillator (ICD) implant to ensure reliable sensing, detection, and defibrillation. Despite its risks, the value was self-evident for early ICDs: failure of defibrillation was common, recipients had a high risk of ventricular tachycardia (VT) or VF, and the only therapy for rapid VT or VF was a shock. Today, failure of defibrillation is rare, the risk of VT/VF is lower in some recipients, antitachycardia pacing is applied for fast VT, and vulnerability testing permits assessment of defibrillation efficacy without inducing VF in most patients. This review reappraises ICD implant testing. At implant, defibrillation success is influenced by both predictable and unpredictable factors, including those related to the patient, ICD system, drugs, and complications. For left pectoral implants of high-output ICDs, the probability of passing a 10 J safety margin is approximately 95%, the probability that a maximum output shock will defibrillate is approximately 99%, and the incidence of system revision based on testing is < or = 5%. Bayes' Theorem predicts that implant testing identifies < or = 50% of patients at high risk for unsuccessful defibrillation. Most patients who fail implant criteria have false negative tests and may undergo unnecessary revision of their ICD systems. The first-shock success rate for spontaneous VT/VF ranges from 83% to 93%, lower than that for induced VF. Thus, shocks for spontaneous VT/VF fail for reasons that are not evaluated at implant. Whether system revision based on implant testing improves this success rate is unknown. The risks of implant testing include those related to VF and those related to shocks alone. The former may be due to circulatory arrest alone or the combination of circulatory arrest and shocks. Vulnerability testing reduces risks related to VF, but not those related to shocks. Mortality from implant testing probably is 0.1-0.2%. Overall, VF should be induced to assess sensing in approximately 5% of ICD recipients. Defibrillation or vulnerability testing is indicated in 20-40% of recipients who can be identified as having a higher-than-usual probability of an inadequate defibrillation safety margin based on patient-specific factors. However, implant testing is too risky in approximately 5% of recipients and may not be worth the risks in 10-30%. In 25-50% of ICD recipients, testing cannot be identified as either critical or contraindicated.  相似文献   

2.
AIMS: Antitachycardia pacing (ATP) has not routinely been used in patients who received implantable cardioverter defibrillators (ICDs) for primary prevention of sudden death. This study investigated the efficacy of empirical ATP to terminate rapid ventricular tachycardia (VT) in heart failure patients with prophylactic ICD therapy. METHODS AND RESULTS: Ninety-three patients with a mean left ventricular ejection fraction of 22 +/- 7% (range: 9-35%) due to nonischemic or ischemic cardiomyopathy received prophylactic ICDs with empiric ATP. At least 2 ATP sequences with 6-pulse burst pacing trains at 81% of VT cycle length (CL) were programmed in one or two VT zones for CL below 335 +/- 23 ms and above 253 +/- 18 ms. Ventricular flutter and fibrillation (VF) with CL below 253 +/- 18 ms were treated in a separate VF zone with ICD shocks without preceding ATP attempts. During 38 +/- 27 months follow-up, 339 spontaneous ventricular tachyarrhythmias occurred in 36 of 93 study patients (39%). A total of 232 VT episodes, mean CL 293 +/- 22 ms, triggered ATP in 25 of 36 patients with ICD interventions (69%). ATP terminated 199 of 232 VT episodes (86%) with a mean CL of 294 +/- 23 ms in 23 of 25 patients (88%) who received ATP therapy. ATP failed to terminate or accelerated 33 of 232 VT episodes (14%) with a mean CL of 287 +/- 19 ms in 12 of 25 patients (48%) who received ATP therapy. CONCLUSIONS: Painfree termination of rapid VT with empirical ATP is common in heart failure patients with prophylactic ICD therapy. The occasional inability of empiric ATP to terminate rapid VT in almost 50% of patients who receive ATP for rapid VT warrants restrictive ICD programming with regard to the number of ATP attempts in order to avoid syncope before VT termination occurs.  相似文献   

3.
A growing number of Japanese patients are being treated with ICDs. Efforts are warranted to minimize the rates of ICD shocks that cause discomfort and anxiety. The circadian distribution of ICD discharges was investigated in 80 patients (57+/-10 years of age, 69 men) from ten Japanese medical centers. The underlying heart disease was ischemic in 27 versus nonischemic in 53 patients. All patients had refractory VT or VF, and received appropriate shocks confirmed by stored data retrieved from the memory of the ICD. In the analysis of 354 appropriate shocks delivered in the overall population, a morning peak in VT or VF episodes was observed. However, subgroup analyses of the circadian distribution of ICD shocks revealed that the morning peak in VT or VF episodes was confined to patients with ischemic heart disease and was blunted by treatment patients with beta-adrenergic blockers. The absence of a morning peak in appropriate ICD shocks among patients with nonischemic heart disease remains unexplained and was unrelated to the use of beta-adrenergic blockers. In conclusion, the circadian pattern of appropriate ICD discharges was related to the underlying heart disease. In patients with ischemic heart disease, recurrences of VT or VF peaked in the morning. In contrast, in patients without ischemic heart disease, the episodes of VT or VF were evenly distributed during waking hours. Beta-adrenergic blockers appeared to blunt the morning peak in VT or VF among patients with ischemic heart disease.  相似文献   

4.
BACKGROUND: It would be useful to identify patients at high risk of implantable cardioverter defibrillator (ICD) therapy via additional antiarrhythmic measures to minimize the morbidity of ICD therapies. OBJECTIVE: We assessed baseline characteristics for predictors of device therapy in a general ICD population. We also compared the likelihood of therapy delivery by replacement ICDs implanted for battery depletion with the original implants. METHODS: Clinical and ICD interrogation data from patients followed up at a UK center were analyzed looking for predictors of appropriate ICD therapy. Univariate and multivariate analysis was performed using Cox regression. We compared time to first appropriate therapy between first and second ICDs in patients who had undergone ICD replacement for battery depletion by log-rank testing. RESULTS: One hundred and sixty-one patients were studied (129 men, age 65.7 +/- 12.9 years, follow-up 908 +/- 676 days). Appropriate therapy was delivered in 68 patients (42%). Univariate risk factors for appropriate ICD therapy were presentation with stable ventricular tachycardia (VT) (P = 0.0002), ischemic etiology (P = 0.03), tiered therapy programmed ICDs (P = 0.01), and beta-blocker use (P = 0.001). Stable VT and beta blocker use were independent predictors of ICD therapy on multivariate analysis. Thirty-three patients (20%) had at least one ICD replacement. Time to first appropriate therapy was no different between first and second ICD implants (P = 0.8). CONCLUSION: Patients who present with cardiovascularly stable VT have a higher probability of receiving appropriate ICD therapy than those who do not. Following battery depletion of an original ICD, the replacement device is no less likely to administer therapy than the first.  相似文献   

5.
Objectives: We evaluated whether electrophysiologic (EP) inducibility predicts the subsequent occurrence of spontaneous ventricular tachycardia (VT) or ventricular fibrillation (VF) in the Defibrillators in Nonischemic Cardiomyopathy Treatment Evaluation (DEFINITE) trial.
Background: Inducibility of ventricular arrhythmias has been widely used as a risk marker to select implantable cardioverter defibrillator (ICD) candidates, but is believed not to be predictive in nonischemic cardiomyopathy patients.
Methods: In DEFINITE, patients randomized to the ICD arm, but not the conventional arm, underwent noninvasive EP testing via the ICD shortly after ICD implantation using up to three extrastimuli at three cycle lengths plus burst pacing. Inducibility was defined as monomorphic or polymorphic VT or VF lasting 15 seconds. Patients were followed for a median of 29 ± 14 months (interquartile range = 2–41). An independent committee, blinded to inducibility status, characterized the rhythm triggering ICD shocks.
Results: Inducibility, found in 29 of 204 patients (VT in 13, VF in 16), was associated with diabetes (41.4% vs 20.6%, P = 0.014) and a slightly higher ejection fraction (23.2 ± 5.9 vs 20.5 ± 5.7, P = 0.021). In follow-up, 34.5% of the inducible group (10 of 29) experienced ICD therapy for VT or VF or arrhythmic death versus 12.0% (21 of 175) noninducible patients (hazard ratio = 2.60, P = 0.014).
Conclusions: In DEFINITE patients, inducibility of either VT or VF was associated with an increased likelihood of subsequent ICD therapy for VT or VF, and should be one factor considered in risk stratifying nonischemic cardiomyopathy patients.  相似文献   

6.
ICDs provide protection against sudden cardiac death in patients with life-threatening ventricular arrhythmias. Nevertheless, most ICD recipients receive adjunctive antiarrhythmic drug therapy to reduce the number of recurrent episodes and ICD discharges. The aim of the study was to compare the efficacy of metoprolol and d,l-sotalol in preventing VT/VF recurrences in patients with an ICD in a prospective, randomized trial. One hundred patients (83 men, 17 women; mean age 59 years, SD +/- 11 years) were randomized to receive metoprolol or sotalol after implantation of an ICD. There were no significant differences between the two groups with regard to age, sex, underlying cardiac disease, left ventricular ejection fraction, NYHA class assessment and clinical arrhythmia. The median follow-up was 728 days (25th percentile: 530 days, 75th percentile: 943 days) in the metoprolol group and 727 days (25th percentile: 472 days, 75th percentile: 1,223 days) in the sotalol group (P = 0.52). Thirty-three patients treated with metoprolol and 30 patients receiving sotalol had at least one episode during the follow-up. Event-free survival curves were generated for the two treatment arms using the Kaplan-Meier method and showed no significant difference (P = 0.68). Eight patients treated with metoprolol and six patients treated with sotalol died during follow-up. Total mortality was not significantly different between the two study groups (P = 0.43). Metoprolol is as efficacious as sotalol in preventing VT/VF recurrences in patients with an ICD.  相似文献   

7.
One‐third of all patients with heart failure have nonischemic dilated cardiomyopathy (NIDM). Five‐year mortality from NIDM is as high as 20% with sudden cardiac death (SCD) as the cause in 30% of the deaths. Currently, the left ventricular ejection fraction (LVEF) is used as the main criteria to risk stratify patients requiring an implantable cardioverter defibrillator (ICD) to prevent SCD. However, LVEF does not necessarily reflect myocardial propensity for electrical instability leading to ventricular tachycardia (VT) or ventricular fibrillation (VF). Due to the differential risk in various subgroups of patients for arrhythmic death, it is important to identify appropriate patients for ICD implantation so that we can optimize healthcare resources and avoid the complications of ICDs in individuals who are unlikely to benefit. We performed a systematic search and review of clinical trials of NIDM and the use of ICDs and cardiac magnetic resonance imaging with late gadolinium enhancement (LGE) for risk stratification. LGE identifies patients with NIDM who are at high risk for SCD and enables optimized patient selection for ICD placement, while the absence of LGE may reduce the need for ICD implantation in patients with NIDM who are at low risk for future VF/VT or SCD.  相似文献   

8.
Appropriate sensing of ventricular tachycardia (VT) and ventricular fibrillation (VF)is of paramount importance for safety of patients with implanted cardioverter defibrillators (ICDs). Recently, the GuardianR ATP 4210, a new third generation ICD that uses programmable but fixed sensing during sinus rhythm and doubles its sensitivity settings when VF is detected, to a maximum programmable sensitivity of 1 mV, has been tested in phase I and II clinical trials. A reconfirmation algorithm of this ICD confirms the presence of VT or VF prior to therapy. This case report describes undersensing of VF in a patient with the GuardianR ATP 4210 at the maximum programmed sensitivity of 1 mV. Inappropriate episodes of asystole and prolonged bradycardias were also observed in this patient due to shortcomings in the reconfirmation algorithm design. Reoperation was required, with positioning of a new endocardial sensing lead to correct the undersensing of VF. This, however, did not correct asystolic pauses following antitachycardia pacing or spontaneous tachycardio termination prior to therapy. This case report highlights the hazards of fixed gain sensing for implantable ICDs and a potential limitation of a specific tachyarrhythmia reconfirmation algorithm used in this device.  相似文献   

9.
INTRODUCTION: Studies of recurrent ventricular tachycardia and ventricular fibrillation (VT/VF) have been limited to "electrical storms," where recurrent arrhythmias necessitate repeated external cardioversions or defibrillations. Patients with an implantable cardioverter-defibrillator (ICD) may also suffer frequently recurrent arrhythmias. The aim of this study was to analyze the temporal pattern and the clinical relevance of clustering ventricular arrhythmias in ICD recipients. METHODS: The incidence and the type of arrhythmias were determined by reviewing stored electrograms. VT/VF clusters were defined as the occurrence of three or more adequate and successful ICD interventions within 2 weeks. Two hundred and fourteen consecutive ICD recipients were followed during an average of 3.3 +/- 2.2 years (698 patient-years). RESULTS: Fifty-one patients (24%) suffered 98 VT/VF clusters 21 +/- 22 months after ICD implantation, 93% of these clusters consisting of recurrent regular VT. Monomorphic VT as index event leading to ICD implantation was the only factor predicting VT/VF clusters. Kaplan-Meier estimates of the combined end-point of death or heart transplantation showed a 5-year event-free survival of 67% versus 87% in patients with and without clusters, respectively (P = 0.026). Adjusted hazard ratios for death or heart transplantation in the group with arrhythmia clusters was 3.5 (95% confidence interval 1.5-7.9 P = 0.003). CONCLUSIONS: VT/VF clusters are frequent late after ICD implantation particularly in patients who had VT as index-event. As arrhythmias and recurrent ICD interventions are responsible for an important morbidity, there is a possible role for a prophylactic intervention. Furthermore, VT/VF clusters are an independent marker of increased risk of death or need for heart transplantation.  相似文献   

10.
Fifty-three consecutive patients with hypertrophic cardiomyopathy (HCM) and no history of sudden death underwent electrophysiology (EP) study. Sustained polymorphic ventricular tachycardia (VT) or ventricular fibrillation (VF) was induced in 19 patients (35%). Patients with prior syncope or near syncope had a higher incidence of VT/VF inducibility. An implantable cardioverter defibrillator (ICD) was placed in 14 of the 19 patients. Of the remaining 5 patients with inducible VT/VF, three refused ICD implantation, while two underwent septal myectomy and VT/VF was no longer inducible afier the operation. None of the patients received antiarrhythmic drugs. During a mean follow-up period of 47 ± 31 (2–117) months, no events occurred in the 34 patients with negative EP study. Three events occurred among the 19 patients with inducible VT/VF. One patient died suddenly, one developed wide complex tachycardia which required resuscitation, and one patient received an appropriate ICD shock. In conclusion, sustained polymorphic VT/VF was inducible in about one-third of patients with HCM. Noninducibility of VT/VF appeared to predict a favorable prognosis. Although the overall event rate was low in patients with inducible VT/VF, prophylactic ICD implantation in patients with multiple risk factors may be appropriate.  相似文献   

11.
GRIMM, W., et al. : Value of Heart Rate Variability to Predict Ventricular Arrhythmias in Recipients of Prophylactic Defibrillators with Idiopathic Dilated Cardiomyopathy. This study investigated the relation between heart rate variability (HRV) measured as standard deviation of normal to normal RR intervals (SDNN) on baseline 24-hour ambulatory electrocardiogram (ECG) and subsequent appropriate implantable cardioverter defibrillator (ICD) interventions in 70 patients with idiopathic dilated cardiomyopathy (IDC) in whom ICDs were implanted prophylactically in the presence of a low left ventricular ejection fraction (LVEF). During   43 ± 26   months of follow-up, 26 of 70 (37%) study patients with IDC received one or more appropriate ICD interventions for sustained ventricular tachycardia (VT) or ventricular fibrillation (VF) documented by electrograms stored in the ICD. Mean SDNN at ICD implant was   94 ± 33 ms   . No difference was found between patients with   (90 ± 25 ms)   versus without   (96 ± 37 ms)   appropriate ICD interventions for VT or VF during follow-up. Multivariate Cox regression analysis of baseline clinical characteristics including age, gender, LVEF, NYHA functional class, nonsustained VT on Holter, history of syncope, left bundle branch block, baseline medication and HRV revealed LVEF as the only significant predictor of arrhythmia. These findings do not support the use of HRV measured as SDNN on 24-hour ambulatory ECG to select patients with IDC for prophylactic ICD therapy. (PACE 2003; 26[Pt. II]:411–415)  相似文献   

12.
Introduction: Data on the mechanisms of sudden cardiac death are limited and may be biased by delays in rhythm recording and selection bias in survivors. As a result, the relative contributions of monomorphic ventricular tachycardia (VT) (cycle length [CL] > 260 ms), monomorphic fast VT (FVT) (CL ≤ 260 ms), and polymorphic VT (PMVT)/ventricular fibrillation (VF) have not been well characterized nor compared in patients with and without prior arrhythmic events. Methods: A retrospective cohort study of implantable cardioverter‐defibrillator (ICD) recipients with primary or secondary implant indications was used to evaluate intracardiac electrograms (EGMs) for the first spontaneous VT/VF resulting in appropriate ICD therapy. EGMs were categorized into VT, FVT, and PMVT/VF based on CL and morphologic criteria. Results: Of 616 implants, 145 patients (58 [40%] primary indications) received appropriate ICD therapy for VT/VF over mean follow‐up of 3.8 ± 3.2 years. Primary implants had more diabetes (28% vs 12%; P = 0.02) and less antiarrhythmic use (15% vs 33%; P = 0.02). In those patients with spontaneous arrhythmia, PMVT/VF occurred in 20.7% of primary versus 21.8% of secondary implants, FVT in 19.0% versus 21.8%, and VT in 60.3% versus 56.4%, respectively (P = 0.88). Spontaneous VT CL was similar regardless of implant indication (284 ± 56 [primary] vs 286 ± 67 ms [secondary]; P = 0.92). Conclusions: Monomorphic VT is the most common cause of appropriate ICD therapy regardless of implant indication. These results provide insight into the mechanisms of sudden cardiac death and have implications for the use of interventions designed to limit ICD shocks. (PACE 2011; 34:571–576)  相似文献   

13.
BACKGROUND: Patients with ischemic cardiomyopathy (ICM) who have monomorphic ventricular tachycardia (VT) induced by programmed ventricular stimulation (PVS) are at increased risk of sudden cardiac death (SCD). Among a primary prevention population, the prognostic significance of induced polymorphic ventricular arrhythmias is unknown. METHODS: A total of 105 consecutive patients who received an implantable cardioverter-defibrillator (ICD) for primary prevention of SCD in the setting of ICM and non-sustained VT were retrospectively evaluated. Seventy-five patients (group I) had induction of monomorphic VT and 30 patients (group II) had a sustained ventricular arrhythmia other than monomorphic VT (ventricular flutter, ventricular fibrillation, and polymorphic VT) induced during PVS. RESULTS: Baseline characteristics were similar between group I and group II except for ejection fraction (25% vs. 31%, P = 0.0001) and QRS duration (123 milliseconds vs. 109 milliseconds, P = 0.04). Sixteen of 75 (21.3%) patients in group I and 6 of 30 (20%) patients in group II received appropriate ICD therapy (P = 0.88). Survival free from ICD therapy was similar between groups (P = 0.54). There was a trend toward increased all-cause mortality among patients in group I by Kaplan-Meier analysis (P = 0.08). However, when adjusted for age, EF, and QRS duration mortality was similar (P = 0.45). CONCLUSIONS: There is no difference in rates of appropriate ICD discharge or mortality between patients dichotomized by type of rhythm induced during PVS. These results suggest that patients in this population who have inducible VF or sustained polymorphic VT have similar rates of subsequent clinical ventricular tachyarrhythmias as those with inducible monomorphic VT.  相似文献   

14.
Third-generation implantable cardioverter defibrillators (ICDs) offer tiered therapy and can provide significant advantage in the management of patients with life-threatening arrhythmias. Three different types of ICDs were implanted in 21 patients with ventricular tachycardia (VT) or ventricular fibrillation (VF). Arrhythmia presentation was VT(76%), VF(10%), or both (14%). The mean left ventricular ejection fraction for the group was 32.4 ± 7%. No surgical mortality occurred. Prior to discharge individual EPS determined the final programmed settings of the ICDs. During a mean follow-up of 13 ± 1.4 months (range 2–20) the overall patient survival was 85.7%. No sudden arrhythmic or cardiac death occurred. Twenty of 21 patients (95%) received therapy by their device. In 14 patients (67%) antitachycardia pacing (A TP) was programmed "on," 13 of which was self-adaptative autodecremental mode. There were 247 VT episodes, 231 of which were subjected to ATP with 97% success and 3% acceleration or failure. Low energy shocks reverted all other VT episodes. VF episodes were successfully reverted by a single shock (93%), two shocks (6%), or three shocks (1 %). We conclude that ATP therapy of VT is successful in the large majority of episodes with rare failures, and that VF episodes are generally terminated by a single ICD shock.  相似文献   

15.
Extensive electrophysiological testing is critical for the effective utilization of sophisticated tachycardia detection and termination algorithms available in tiered therapy ICDs. To evaluate the safety and diagnostic yield of electrophysiological testing via noninvasive ventricular stimulation, we performed 294 electrophysiological studies in 154 patients (age 65 ± 10; left ventricular ejection fraction 0.36 ± 0.15) with tiered therapy ICDs. Stimulation was performed under methohexital anesthesia. A total of 928 sustained ventricular tachyarrhythmias were induced (3.1 ± 2.5 per procedure); monomorphic VT, 550; ventricular flutter, 74; and VF, 246. The results of invasive and noninvasive programmed stimulation were compared for 79 patients wbo had both studies under similar treatment. Overall concordance iras 83%, and did not differ significantly between patients who bad the noninvasive stimulation via epicardial or endocardial pacing leads. VF could be induced in 206 of 257 studies (82%), and it was less likely to be induced in patients on amiodarone (74% vs 85%; P = 0.02), or beta blockers (55% vs 83%; P = 0.017). No patient presented a serious complication. Minor complications occurred during 39 studies; transient laryngospasm in 1, unintended delivery of an ICD sbock to a conscious patient in 4; induction of sustained atrial fibrillation in 8; need for external rescue defibrillation sbocks in 13; and delivery of inappropriate sbocks for supraventricular rhythms in 14 studies. Noninvasive ventricular stimulation performed under methobexital anestbesia is safe. Its diagnostic yield compares favorably with that of conventional electropbysiological studies. VF can be induced in a majority of patients. There is good correlation between invasive and noninvasive programmed stimulation for induction of VT. Noninvasive ventricular stimulation may emerge as standard procedure for the initial programming and follow-up of ICDs.  相似文献   

16.
Background: Even though the intraoperative threshold testing of the implantable cardioverter defibrillator ( ICD ) may cause hemodynamic impairment or be unfeasible, it is still considered required standard practice at the time of implantation. We compared the outcome of ICD recipients who underwent defibrillation threshold testing (DFT) with that of patients in whom no testing was performed.
Methods: A total of 291 subjects with ischemic dilated cardiomyopathy received transvenous ICDs between January 2000 and December 2004 in five Italian cardiology centers. In two centers, DFT was routinely performed in 137 patients (81% men; mean age 69 ± 9 years; mean ejection fraction 26 ± 4%) (DFT group), while three centers never performed DFT in 154 patients (90% men; mean age 69 ± 9 years; mean ejection fraction 27 ± 5%) (no-DFT group).
Results: We compared total mortality, total cardiovascular mortality, sudden cardiac death (SCD), and spontaneous episodes of ventricular arrhythmia (sustained ventricular tachycardia, VT, and ventricular fibrillation, VF) between these groups 2 years after implantation (median 23 months, 25th–75th percentile, 12–44 months). On comparing the DFT and no-DFT groups, we found an overall mortality rate of 20% versus 16%, cardiovascular mortality of 13% versus 10%, SCD of 3% versus 0.6%, VT incidence of 8% versus 10%, and VF incidence of 6% versus 4% (no significant difference in any comparison).
Conclusions: No significant differences in the incidence of clinical outcomes considered emerged between no-DFT and DFT groups. These results should be confirmed in larger prospective studies.  相似文献   

17.
Unnecessary shocks by ICDs for rhythms other than sustained VT or VF have been described as the most frequent adverse event in ICD patients. To avoid unnecessary shocks for self-terminating arrhythmias, the third-generation Jewel PCD defibrillators 7202, 7219, and 7220 Plus use a specially designed VF confirmation algorithm after charge end. The purpose of this study was to determine the ability of this VF confirmation algorithm to recognize nonsustained VT, and to analyze the reasons for failure of the PCD device to abort shock therapy for nonsustained VT despite use of this VF confirmation algorithm. Analysis of stored electrograms of electrical events triggering high voltage capacitor charging in the programmed VF zone of the device showed 36 spontaneous episodes of nonsustained VT (227 ± 21 beats/mm) during 18 ± 7 months follow-up in 15 patients who had a Jewel PCD implanted at our hospital. Intracardiac electrogram recordings and simultaneously retrieved marker channels demonstrated that the ICD shock was appropriately aborted according to the VF confirmation algorithm in 24 (67%) of 36 episodes of nonsustained VT. Twelve episodes (33%) of nonsustained VT, however, were followed by a spontaneous ICD shock in 6 (40%) of the 15 study patients. The only reason for all 12 shocks for nonsustained VT was the inability of the device to recognize the absence of VT after charge end due to shortcomings of the VF confirmation algorithm: 11 of the 12 shocks for nonsustained VT were triggered by the occurrence of paced beats during the VF confirmation period and 1 shock for nonsustained VT was triggered by the occurrence of 2 premature beats after charge end. Thus, better VF confirmation algorithms need to be incorporated in future PCD devices to avoid unnecessary shocks for nonsustained VT.  相似文献   

18.
BACKGROUND: Chronic renal insufficiency (CRI) has been associated with increased risk of cardiovascular morbidity and mortality. However, there is limited knowledge regarding this association and the effect of renal dysfunction on survival benefit in patients with implantable cardioverter-defibrillators (ICDs). METHODS: We investigated whether there was an association between CRI (defined as serum creatinine levels >or=1.5 mg/dL) and increased risk of mortality in ICD recipients. We retrospectively studied all patients (n = 336) followed within our ICD clinic in a 2.5-year period. CRI, ventricular tachycardia (VT), cardiomyopathy (CM), and mortality were recorded. Ischemic CM was defined as the presence of coronary artery disease (CAD) and left ventricular ejection fraction 相似文献   

19.
VF is induced during ICD implantation to determine efficacy of therapy. Establishing the best clinical method of induction of VF would potentially be beneficial in reducing the number of induction attempts and reducing the frequency of inadvertent induction of VT. Commonly used methods to induce VF include shock in the T wave vulnerable period (T shock) and high frequency stimulation. This study compared the efficacy of T shock with a new induction method using a 9-V DC pulse. The study was a randomized, prospective, case crossover trial in patients receiving ICDs. VF was induced by T shock and DC in a randomized sequence during an ICD implant. VF was induced at least four times in each patient (two T shocks and two DC inductions) and with each induction; attempts were continued with modifications until successful. A paired evaluation between the T shock/DC induction was performed in 37 patients (28 men, age 64 +/- 12 years) with a left ventricular ejection fraction of 0.40 +/- 0.20. Arrhythmia indications were VT (n = 23), VF (n = 10), and VT/VF (n = 4). Drug therapy included amiodarone (n = 10), metoprolol (n = 6), digoxin (n = 1), and lidocaine (n = 1). The average T shock voltage was 207.0 +/- 16.1 V. The S1 cycle drive length was consistently 400 ms, and the mean S2 coupling interval was 317.8 +/- 19.6 ms. The length of time DC applied averaged 3.8 +/- 1.4 seconds. A total of 148 episodes of VF were included in the analysis. T shock induced VF with a cycle length of 213.5 +/- 35.1 ms, and DC induced VF with a cycle length of 214.6 +/- 34.5 ms (P = 0.86). Although VF was eventually induced for each randomization, the number of attempts required were dependent on the method of induction. The successful DC first attempt VF induction rate was 96%, with three patients requiring two attempts during one of the DC inductions. T shock had a 68% first attempt success rate with 21 patients requiring multiple T shocks to induce VF. All nine female patients had at least one unsuccessful first attempt T shock, which contributed to an overall unsuccessful first attempt induction rate significantly higher in women then men (36.1% vs 12.5%, P = 0.001). A constant DC voltage induction of VF may be more effective than T shock for induction of VF in a clinical setting because it reduces the number of attempts required to induce VF. By either method, VF appears to be more difficult to induce in women. DC induction has the advantage of simple programming of only duration of stimulation. These findings have implications particularly for ICD implantation with conscious sedation.  相似文献   

20.
The aim of this study was to describe the indications for upgrade of pacemakers (PMs) or single chamber (VVIR) ICDs to dual chamber (DDDR) ICDs, surgical approach, hardware hybridization, and clinical outcome. Patients with preexisting PMs or VVIR ICDs may develop indications for ICD therapy or dual chamber pacing, respectively, that can be served by DDDR ICDs that incorporate preexisting transvenous leads. Fifty-seven patients underwent upgrade from PMs (29/57) or VVIR ICDs (28/57) to pectoral DDDR ICDs. Preexisting transvenous atrial and/or ventricular leads suitable for continued use were incorporated into new DDDR ICDs in 88.5% and 100% of PM and VVIR ICD upgrades, respectively. Acceptable DFTs were achieved in 56 (98.2%) of 57 patients. Appropriate VT/VF therapies were registered among 33.3% of patients during follow-up. No shocks due to lead noise were observed in any patient with hybridized transvenous leads. Atrial far-field R wave (FFRW) oversensing occurred in 24% of DDDR ICD systems incorporating a preexisting atrial lead. FFRW was overcome by programming reduced atrial sensitivity without interfering with the normal ICD system performance in all instances. Upgrade of PMs and VVIR ICDs to pectoral DDDR ICDs is safe and technically feasible in most patients. Preexisting transvenous leads can be successfully incorporated into new DDDR ICDs, simplifying the surgical procedure, minimizing transvenous hardware, and eliminating the possibility of hazardous pacemaker-ICD interactions.  相似文献   