A new magnetic bearing has been designed to achieve a low electronic power requirement and high stiffness. The magnetic bearing consists of 1) radial passive forces between the permanent magnet ring mounted inside the impeller rotor and the electromagnet core materials in the pump casing and 2) radial active forces generated by the electromagnets using the two gap sensor signals. The magnetic bearing was assembled into a centrifugal rotary blood pump (CRBP) driven with a radial, magnetic coupled driver. The impeller vane shape was designed based upon the computational fluid dynamic simulation. The diameter and height of the CRBP were 75 mm and 50 mm, respectively. The magnetic bearing system required the power of 1.0-1.4 W. The radial impeller movement was controlled to within +/- 10 microm. High stiffness in the noncontrolled axes, Z, phi, and theta, was obtained by the passive magnetic forces. The pump flow of 5 L/min against 100 mm Hg head pressure was obtained at 1,800 rpm with the electrical to hydraulic efficiency being greater than 15%. The Normalized Index of Hemolysis (NIH) of the magnetic bearing CRBP was one fifth of the BioPump BP-80 and one half of the NIKKISO HPM-15 after 4 hours. The newly designed magnetic bearing with two degrees of freedom control in combination with optimized impeller vane was successful in achieving an excellent hemolytic performance in comparison with the clinical centrifugal blood pumps.  相似文献   

2.
A magnetically suspended centrifugal blood pump with a self bearing motor has been developed for long-term ventricular assistance. A rotor of the self bearing motor is actively suspended and rotated by an electromagnetic field without mechanical bearings. Radial position of the rotor is controlled actively, and axial position of the rotor is passively stable within the thin rotor structure. An open impeller and a semiopened impeller were examined to determine the best impeller structure. The outer diameter and height of the impeller are 63 and 34 mm, respectively. Both the impellers indicated similar pump performance. Single volute and double volute structures were also tested to confirm the performance of the double volute. Power consumption for levitation and radial displacement of the impeller with a rotational speed of 1,500 rpm were 0.7 W and 0.04 mm in the double volute, while those in the single volute were 1.3 W and 0.07 mm, respectively. The stator of the self bearing motor was redesigned to avoid magnetic saturation and improve motor performance. Maximum flow rate and pressure head were 9 L/min and 250 mm Hg, respectively. The developed magnetically suspended centrifugal blood pump is a candidate for an implantable left ventricular assist device.  相似文献   

3.
Novel maglev pump with a combined magnetic bearing   总被引:1,自引:0,他引:1  
The newly developed pump is a magnetically levitated centrifugal blood pump in which active and passive magnetic bearings are integrated to construct a durable ventricular assist device. The developed maglev centrifugal pump consists of an active magnetic bearing, a passive magnetic bearing, a levitated impeller, and a motor stator. The impeller is set between the active magnetic bearing and the motor stator. The active magnetic bearing uses four electromagnets to control the tilt and the axial position of the impeller. The radial movement of the levitated impeller is restricted with the passive stability dependent upon the top stator and the passive permanent magnetic bearing to reduce the energy consumption and the control system complexity. The top stator was designed based upon a magnetic field analysis to develop the maglev pump with sufficient passive stability in the radial direction. By implementing this analysis design, the oscillating amplitude of the impeller in the radial direction was cut in half when compared with the simple shape stator. This study concluded that the newly developed maglev centrifugal pump displayed excellent levitation performance and sufficient pump performance as a ventricular assist device.  相似文献   

4.
In this study, a seal-less, tiny centrifugal rotary blood pump was designed for low-flow circulatory support in children and infants. The design was targeted to yield a compact and priming volume of 5 ml with a flow rate of 0.5-4 l/min against a head pressure of 40-100 mm Hg. To meet the design requirements, the first prototype had an impeller diameter of 30 mm with six straight vanes. The impeller was supported with a needle-type hydrodynamic bearing and was driven with a six-pole radial magnetic driver. The external pump dimensions included a pump head height of 20 mm, diameter of 49 mm, and priming volume of 5 ml. The weight was 150 g, including the motor driver. In the mock circulatory loop, using fresh porcine blood, the pump yielded a flow of 0.5-4.0 l/min against a head pressure of 40-100 mm Hg at a rotational speed of 1800-4000 rpm using 1/4" inflow and outflow conduits. The maximum flow and head pressure of 5.25 l/min and 244 mm Hg, respectively, were obtained at a rotational speed of 4400 rpm. The maximum electrical-to-hydraulic efficiency occurred at a flow rate of 1.5-3.5 l/min and at a rotational speed of 2000-4400 rpm. The normalized index of hemolysis, which was evaluated using fresh porcine blood, was 0.0076 g/100 l with the impeller in the down-mode and a bearing clearance of 0.1 mm. Further refinement in the bearing and magnetic coupler are required to improve the hemolytic performance of the pump. The durability of the needle-type hydrodynamic bearing and antithrombotic performance of the pump will be performed before clinical applications. The tiny centrifugal blood pump meets the flow requirements necessary to support the circulation of pediatric patients.  相似文献   

5.
The purpose of this article is to present test results for a second generation, high efficiency, nonpulsatile centrifugal blood pump that is being developed for use as a left ventricular assist device (LVAD). The LVAD pump uses a hybrid passive-active magnetic bearing support system that exhibits extremely low power loss, low vibration, and high reliability under transient conditions and varying pump orientations. A unique feature of the second generation design configuration is the very simple and direct flow path for both main and washing blood flows. The pump was tested in both vertical and horizontal orientations using a standard flow loop to demonstrate the performance and durability of the second generation LVAD. Steady state and transient orientation pump operating characteristics including pressure, flow, speed, temperatures, vibration, and rotor orientation were measured. During the tests, pump performance was mapped at several operating conditions including points above and below the nominal design of 5 L/min at 100 mm Hg pressure rise. Flow rates from 2 to 7 L/min and pressure rises from 50 to 150 mm Hg were measured. Pump speeds were varied during these tests from 2,500 to 3,500 rpm. The nominal design flow of 5 L/min at 100 mm Hg pressure rise was successfully achieved at the design speed of 3,000 rpm. After LVAD performance testing, both 28 day continuous duty and 5 day transient orientation durability tests were completed without incident. A hydrodynamic backup bearing design feasibility study was also conducted. Results from this design study indicate that an integral hydrodynamic backup bearing may be readily incorporated into the second generation LVAD and other magnetically levitated pump rotors.  相似文献   

6.
Magnetic bearings have no mechanical contact between the rotor and stator, and a rotary pump with magnetic bearings therefore has no mechanical wear and thrombosis. The magnetic bearings available, however, contain electromagnets, are complicated to control and have high energy consumption. Therefore, it is difficult to apply an electromagnetic bearing to a rotary pump without disturbing its simplicity, reliability and ability to be implanted. The authors have developed a levitated impeller pump using only permanent magnets. The rotor is supported by permanent radial magnetic forces. The impeller is fixed on one side of the rotor; on the other side the rotor magnets are mounted. Opposite these rotor magents, a driving magnet is fastened to the motor axis. Thereafter, the motor drives the rotor via magnetic coupling. In laboratory tests with saline, where the rotor is still or rotates at under 4,000 rpm, the rotor magnets have one point in contact axially with a spacer between the rotor magnets and the driving magnets. The contacting point is located in the center of the rotor. As the rotating speed increases gradually to more than 4000 rpm, the rotor will disaffiliate from the stator axially, and become fully levitated. Since the axial levitation is produced by hydraulic force and the rotor magnets have a giro-effect, the rotor rotates very stably during levitation. As a left ventricular assist device, the pump works in a rotating speed range of 5,000-8,000 rpm, and the levitation of the impeller is assured by use of the pump. The permanent maglev impeller pump retains the advantages of the rotary pump but overcomes the disadvantages of the leviated pump with electromagnetic-bearing, and has met with most requirements of artificial heart blood pumps, thus promising to have more applications than previously.  相似文献   

7.
Magnetic bearings have no mechanical contact between the rotor and stator, and a rotary pump with magnetic bearings therefore has no mechanical wear and thrombosis. The magnetic bearings available, however, contain electromagnets, are complicated to control and have high energy consumption. Therefore, it is difficult to apply an electromagnetic bearing to a rotary pump without disturbing its simplicity, reliability and ability to be implanted. The authors have developed a levitated impeller pump using only permanent magnets. The rotor is supported by permanent radial magnetic forces. The impeller is fixed on one side of the rotor; on the other side the rotor magnets are mounted. Opposite these rotor magents, a driving magnet is fastened to the motor axis. Thereafter, the motor drives the rotor via magnetic coupling. In laboratory tests with saline, where the rotor is still or rotates at under 4000 rpm, the rotor magnets have one point in contact axially with a spacer between the rotor magnets and the driving magnets. The contacting point is located in the center of the rotor. As the rotating speed increases gradually to more than 4000 rpm, the rotor will disaffiliate from the stator axially, and become fully levitated. Since the axial levitation is produced by hydraulic force and the rotor magnets have a giro-effect, the rotor rotates very stably during levitation. As a left ventricular assist device, the pump works in a rotating speed range of 5000-8000 rpm, and the levitation of the impeller is assured by use of the pump. The permanent maglev impeller pump retains the advantages of the rotary pump but overcomes the disadvantages of the leviated pump with electromagnetic-bearing, and has met with most requirements of artificial heart blood pumps, thus promising to have more applications than previously.  相似文献   

8.
目的:为了改善电磁轴承结构复杂、体积偏大,液力轴承承载力小、不能在较大负载下工作的弊端,提出一种流道型磁液悬浮轴流血泵,提高血泵承载能力。方法:流道型轴流血泵轴向采用永磁力进行支承,径向采用转子叶轮的流道结构产生的液力悬浮;利用Ansys对轴向瞬态磁场进行仿真,对磁力变化进行研究,利用Fluent对不同开槽方向、角度、深度的径向液力进行仿真,对液力变化进行研究。结果:根据轴向磁力随位移的变化,得出磁力最大为2.9 N,楔形开槽结构倾斜角为28°,开槽数为5,槽深0.36 mm,叶顶间隙为0.40 mm,性能达到最优,能满足人体使用。结论:流道型轴流血泵相对于普通磁液悬浮血泵有更高的承载力,较好的悬浮性能,为轴流血泵的优化研究提供了新的思路。  相似文献   

9.
For better anatomic and physiologic fitting, a novel implantable aortic valvo-pump (IAVP) has been developed. A valvo-pump is a micro axial flow impeller pump, which has the same dimensions and function, as well as the same location, of a valve. Therefore, IAVP needs no inlet and outlet tubes, no additional anatomic occupation, and has less physiologic disturbance to natural circulation compared with the traditional bypass left ventricular assist device (LVAD). The device has a stator and a rotor. The stator consists of a motor coil with an iron core and an outflow guide vane; the rotor includes driven magnets and impeller. There is neither bearing nor strut in both the pump and the motor. In order to reduce the attractive force between the rotor and the stator, so as to enhance the durability of the performance, the rotor magnets were minimized without reducing the driving torque and efficiency of the motor. The impeller vane was designed according to a three-dimensional and analytical method, for preventing stasis and turbulence. The largest outer diameter is 24.7 mm and the length at this point is 12.4 mm. The total weight is 40 g (including the rotor of 11 g). The consumed power is 7 W (14 V x 0.5 A) at 15 000 rpm. This rotating speed stays unchanged during haemodynamic testing together with a pulsatile centrifugal pump, which imitates a failing ventricle. The maximal flow cross IAVP reaches over 10 l min(-1) and the pressure head at 0 l min(-1) can be as large as 80 mmHg. At flow rate of 4 - 8 l min(-1), IAVP enlarges the flow c. 1 l min(-1) and meanwhile increases the pressure about 10 mmHg. The pressure pulsatility generated by the pulsatile centrifugal pump remains 40 mmHg after passing IAVP. By first animal experimental trial the device was sewed in aortic position of an 80 kg pig without harm to adjacent tissue and organs. IAVP promises to be a viable alternative to natural donor heart for heart transplantation in the future.  相似文献   

10.
Based on the development of an impeller total artificial heart (TAH) (1987) and a permanent maglev (magnetic levitation) impeller pump (2002), as well as a patented magnetic bearing and magnetic spring (1996), a novel permanent maglev impeller TAH has been developed. The device consists of a rotor and a stator. The rotor is driven radially. Two impellers with different dimensions are fixed at both the ends of the rotor. The levitation of the rotor is achieved by using two permanent magnetic bearings, which have double function: radial bearing and axial spring. As the rotor rotates at a periodic changing speed, two pumps deliver the pulsatile flow synchronously. The volume balance between the two pumps is realized due to self-modulation property of the impeller pumps, without need for detection and control. Because the hemo-dynamic force acting on the left impeller is larger than that on the right impeller, and this force during systole is larger than that during diastole, the rotor reciprocates axially once a cycle. This is beneficial to prevent the thrombosis in the pump. Furthermore, a small flow via the gap between stator and rotor from left pump into right pump comes to a full washout in the motor and the pumps. Therefore, it seems neither mechanical wear nor thrombosis could occur. The previously developed prototype impeller TAH had demonstrated that it could operate in animal experiments indefinitely, if the bearing would not fail to work. Expectantly, this novel permanent magnetic levitation impeller TAH with simplicity, implantability, pulsatility, compatibility and durability has satisfied the most requirements on blood pumps and will have more extensive applications in experiments and clinics.  相似文献   

11.
磁力轴承没有机械接触,机械旋转泵应用磁力轴承后就可以解决机械磨损及轴承处产生血栓的问题,但是,国外使用的磁力轴承均是电磁铁加位置测量及反馈控制,不仅结构复杂,体积大,而且消耗附加电能,整个系统的可靠性也差,作者探索用永久磁铁制作磁力轴承,研制成改进型无源磁浮叶轮泵,泵的转子径向由永磁体磁力支承,转子的一端紧固着叶轮,另一端镶嵌磁钢;与转子磁钢相对,驱动电机线圈产生旋转磁场,驱动转子旋转,在实验室用生理盐水试验,当转子静止或低于4000rpm旋转时,转子磁钢在轴向同位于转子和定子之间的隔板有一点接触,接触点位于转子的轴线上,当转子转速逐渐增加至4000rpm以上,转子在轴向与定子脱离,从而实现完全磁浮,由于转子轴向磁浮由液动力产生,且转子磁钢有陀螺效应,所以转子在浮起的过程中运转非常平稳,当用作左心室辅助装置时,叶轮血泵工作转速范围在5000-8000rpm之间,所以实用时转子完全磁浮是不成问题的,无源磁浮技术是对Earnshaw理论(1842)及Braunbeck推论(1939)的重大补充,将在其它科技领域得到广泛应用。  相似文献   

12.
For better anatomic and physiologic fitting, a novel implantable aortic valvo-pump (IAVP) has been developed. A valvo-pump is a micro axial flow impeller pump, which has the same dimensions and function, as well as the same location, of a valve. Therefore, IAVP needs no inlet and outlet tubes, no additional anatomic occupation, and has less physiologic disturbance to natural circulation compared with the traditional bypass left ventricular assist device (LVAD). The device has a stator and a rotor. The stator consists of a motor coil with an iron core and an outflow guide vane; the rotor includes driven magnets and impeller. There is neither bearing nor strut in both the pump and the motor. In order to reduce the attractive force between the rotor and the stator, so as to enhance the durability of the performance, the rotor magnets were minimized without reducing the driving torque and efficiency of the motor. The impeller vane was designed according to a three-dimensional and analytical method, for preventing stasis and turbulence. The largest outer diameter is 24.7 mm and the length at this point is 12.4 mm. The total weight is 40 g (including the rotor of 11 g). The consumed power is 7 W (14 V?×?0.5 A) at 15?000 rpm. This rotating speed stays unchanged during haemodynamic testing together with a pulsatile centrifugal pump, which imitates a failing ventricle. The maximal flow cross IAVP reaches over 10 l min?1 and the pressure head at 0 l min?1 can be as large as 80 mmHg. At flow rate of 4?–?8 l min?1, IAVP enlarges the flow c. 1 l min?1 and meanwhile increases the pressure about 10 mmHg. The pressure pulsatility generated by the pulsatile centrifugal pump remains 40 mmHg after passing IAVP. By first animal experimental trial the device was sewed in aortic position of an 80 kg pig without harm to adjacent tissue and organs. IAVP promises to be a viable alternative to natural donor heart for heart transplantation in the future.  相似文献   

13.
One of the key technologic requirements for rotary blood pumps is the sealing of the motor shaft. A mechanical seal, a journal bearing, magnetic coupling, and magnetic suspension have been developed, but they have drawbacks such as wear, thrombus formation, and power consumption. A magnetic fluid seal was developed for an axial flow pump. A magnetic fluid seal is durable, simple, and non power consumptive. Long-term experiments and finite element modeling (FEM) analyses confirmed these advantages. The seal body was composed of a Ned-Fe magnet and two pole pieces; the seal was formed by injecting ferrofluid into the gap (50 microm) between the pole pieces and the motor shaft. To contain the ferrofluid in the seal and to minimize the possibility of ferrofluid making contact with blood, a shield with a small cavity was attached to the pole piece. While submerged in blood, the sealing pressure of the seal was measured and found to be 188 mm Hg with ferrofluid LS-40 (saturated magnetization, 24.3 kA/m) at a motor speed of 10,000 rpm and 225 mm Hg under static conditions. The magnetic fluid seals performed perfectly at a pressure of 100 mm Hg for 594 + days in a static condition, and 51, 39+, and 34+ days at a motor speed of 8,000 rpm. FEM analyses indicated a theoretical sealing pressure of 260 mm Hg. The state of the magnetic fluid in the seal in water was observed with a microscope. Neither splashing of magnetic fluid nor mixing of the magnetic fluid and water was observed. The specially designed magnetic fluid seal for keeping liquids out is useful for axial flow blood pumps. The magnetic fluid seal was incorporated into an intracardiac axial flow pump.  相似文献   

14.
An implantable centrifugal blood pump has been developed with original features for a ventricle assist device (VAD). This pump is part of a multicenter and international study with objective to offer simple, affordable, and reliable devices to developing countries. Previous computational fluid dynamics investigations were performed followed by prototyping and in vitro tests. Also, previous blood tests for assessment of hemolysis showed mean normalized index of hemolysis (NIH) results of 0.0054 ± 2.46 × 10?3 mg/100 L (at 5 L/min and 100 mm Hg). To precede in vivo evaluation, measurements of magnetic coupling interference and enhancements of actuator control were necessary. Methodology was based on the study of two different work situations (1 and 2) studied with two different types of motors (A and B). Situation 1 is when the rotor of pump is closest to the motor and situation 2 its opposite. Torque and mechanical power were collected with a dynamometer (80 g/cm) and then plotted and compared for two situations and both motors. The results showed that motor A has better mechanical behavior and less influence of coupling. Results for situation 1 showed that it is more often under magnetic coupling influence than situation 2. The studies lead to the conclusion that motor A is the best option for in vivo studies as it has less influence of magnetic coupling in both situations.  相似文献   

15.
A long-term, compact left ventricular assist device (LVAD), the HeartMate III, has been designed and fabricated, featuring a centrifugal pump with a magnetically levitated rotor. The pump has been optimized by in vitro testing to achieve a design point of 7 L/min against 135 mm Hg at high hydrodynamic efficiency (30%) and to be capable of up to 10 L/min under such a load. Furthermore, the pump has demonstrated no mechanical failures, low hemolysis (4-10 mg/dl plasma free Hb), and low thrombogenicity during six (40, 27, 59, 42, 27, and 49-day) in vivo bovine studies.  相似文献   

16.
永磁磁浮叶轮血泵及转子悬浮性能分析   总被引:2,自引:1,他引:1  
为了消除叶轮血泵内的机械磨损、延长血泵的使用寿命,血泵均采用电磁悬浮技术,但是电磁磁浮有许多不适合血泵的弊端.本文介绍的永磁磁浮叶轮血泵采用一种新颖的永磁轴承,该轴承由两个大小不同、充磁方向相同的同心磁环组成,具有轴向弹簧和径向轴承的双重功能.作者利用实验室自制叶轮血泵转子位置测试系统测量转子的位置.数据处理结果表明,血泵的转速越高、流量越大、气隙越小越有利于叶轮血泵转子悬浮.此外,还讨论了采用三种不同形式永磁轴承的叶轮血泵转子的悬浮性能.  相似文献   

17.
In the early 1990s, Yamazaki et al. developed a partly intra-ventricular pump, which was inserted into the left ventricle via the apex and then into the aorta through the aortic valve. The pump delivered blood flow directly from the left ventricle to the aorta, like a natural heart, and needed no inflow and outflow connecting tubes; it could be weaned off after the left ventricle had been recovered. The shortcomings were that the driving DC motor remained outside of the ventricle, causing an anatomic space problem, and the sealing and bearing were not appropriate for a durable device. Recently, a totally implantable trans-ventricular pump has been developed in the authors' laboratory. The device has a motor and a pump entirely contained within one cannula. The motor has a motor coil with iron core and a rotor with four-pole magnet; the pump has an impeller and an outflow guide vane. The motor part is 60 mm in length and 13 mm in diameter; the pump part is 55 mm in length and 11 mm in diameter. The total length of the device is therefore 115 mm. The total weight of the device is 53 g. The motor uses rolling bearing with eight needles on each side of the rotor magnets. A special purge system is devised for the infusion of saline mixed with heparin through bearing to the pump inlet (30 - 50 cc per hour). Thus neither mechanical wear nor thrombus formation along the bearing will occur. In haemodynamic testing, the pump can produce a flow of 4 l min-1 with 60 mmHg pressure increase, at a pump rotating speed of 12,500 rpm. At zero flow rate, corresponding to the diastolic period of the heart, the pump can maintain aortic blood pressure over 80 mmHg at the same rotating speed. This novel pump can be quickly inserted in an emergency and easily removed after recovery of natural heart. It will be useful for patients with acute left ventricular failure.  相似文献   

18.
为了延长血泵使用寿命 ,目前除了电磁磁浮还没有更好的解决办法 ,但是电磁磁浮需要位置检测和反馈控制 ,而且增加能耗、可靠性差 ,因此提出了永磁减载的新方法。介绍了一种新颖的永磁轴承 ,它具有径向支承和轴向弹簧的双重作用。在血泵驱动电机的两端安装两个永磁轴承 ,既可以为转子提供径向减载 ,又可以使转子轴向悬浮。为了减小定子与转子之间的摩擦 ,除了提高轴承的径向支承力以外 ,还要减小定子铁心对转子磁钢的径向吸引力 ,解决的办法是适当减小铁心和转子磁钢的用量 ,同时增大定子与转子间的气隙。通过实验研究转子磁钢参数和气隙的变化对电机效率的影响 ,可以确定转子磁钢的尺寸和气隙值 ,从而使电机保持高效率运转 ,同时又实现了永磁减载。通过永磁减载方法设计的耐久性叶轮血泵已连续稳定运转八个月 ,振动小 ,噪音低 ,进一步深入研究正在进行之中  相似文献   

19.
We have developed a centrifugal blood pump with a magnetically suspended impeller to reduce the hemolysis level for long-term use. The main advance we have made was simplifying the traditional 5 axes controlled magnetic bearing system, since the total device should ultimately be small enough to implant into a human body. A simplified magnetic bearing system with only 3 actively controlled axes was designed to levitate the impeller. The state equations of the magnetic bearing plant were established using Lagrange's methods, and using the results, a linear quadratic optimal controller was designed to regulate the position of the impeller. Flow rate and differential pressure of 5L/min and 300 mmHg, respectively at a motor speed of 2750 rpm was achieved from a mock circulation setup. These results show satisfactory performance as a cardiopulmonary bypass device. The lowering of pumping efficiency as the clearance between the impeller and pump housing increased was negligible. Thus for power efficiency, the smallest gap not leading to a hemolysis level rise can be determined as a feasible operation clearance.  相似文献   

20.
In the early 1990s, Yamazaki et al. developed a partly intra-ventricular pump, which was inserted into the left ventricle via the apex and then into the aorta through the aortic valve. The pump delivered blood flow directly from the left ventricle to the aorta, like a natural heart, and needed no inflow and outflow connecting tubes; it could be weaned off after the left ventricle had been recovered. The shortcomings were that the driving DC motor remained outside of the ventricle, causing an anatomic space problem, and the sealing and bearing were not appropriate for a durable device. Recently, a totally implantable trans-ventricular pump has been developed in the authors' laboratory. The device has a motor and a pump entirely contained within one cannula. The motor has a motor coil with iron core and a rotor with four-pole magnet; the pump has an impeller and an outflow guide vane. The motor part is 60 mm in length and 13 mm in diameter; the pump part is 55 mm in length and 11 mm in diameter. The total length of the device is therefore 115 mm. The total weight of the device is 53 g. The motor uses rolling bearing with eight needles on each side of the rotor magnets. A special purge system is devised for the infusion of saline mixed with heparin through bearing to the pump inlet (30 – 50 cc per hour). Thus neither mechanical wear nor thrombus formation along the bearing will occur. In haemodynamic testing, the pump can produce a flow of 4 l min?1 with 60 mmHg pressure increase, at a pump rotating speed of 12 500 rpm. At zero flow rate, corresponding to the diastolic period of the heart, the pump can maintain aortic blood pressure over 80 mmHg at the same rotating speed. This novel pump can be quickly inserted in an emergency and easily removed after recovery of natural heart. It will be useful for patients with acute left ventricular failure.  相似文献   