首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
ObjectivesThe aim of this study was to compare 1-year outcomes after transcatheter aortic valve replacement (TAVR) in low surgical risk patients with bicuspid aortic stenosis to patients with tricuspid aortic stenosis.BackgroundThe pivotal TAVR trials excluded patients with bicuspid aortic valves. The Low Risk Bicuspid Study 30-day primary endpoint of death or disabling stroke was 1.3%.MethodsThe Low Risk Bicuspid Study is a prospective, single-arm, TAVR trial that enrolled patients from 25 U.S. sites. A screening committee confirmed bicuspid anatomy and valve classification on computed tomography using the Sievers classification. Valve sizing was by annular measurements. An independent clinical events committee adjudicated all serious adverse events, and an independent core laboratory assessed all echocardiograms. The 150 patients from the Low Risk Bicuspid Study were propensity matched to the TAVR patients in the randomized Evolut Low Risk Trial using the 1:1 5- to-1-digit greedy method, resulting in 145 pairs.ResultsAll-cause mortality or disabling stroke at 1 year was 1.4% in the bicuspid and 2.8% in the tricuspid group (P = 0.413). A pacemaker was implanted in 16.6% of bicuspid and 17.9% of tricuspid patients (P = 0.741). The effective orifice area was similar between groups at 1 year (2.2 ± 0.7 cm2 vs 2.3 ± 0.6 cm2, P = 0.677) as was the mean gradient (8.7 ± 3.9 mm Hg vs 8.5 ± 3.1 mm Hg, P = 0.754). Fewer patients in the bicuspid group had mild or worse paravalvular leak (21.3% vs 42.6%, P < 0.001).ConclusionsThere were no significant differences in clinical or forward flow hemodynamic outcomes between the propensity-matched groups at 1 year.  相似文献   

2.
ObjectivesThe aim of this study was to prospectively evaluate the clinical use of patient-specific computer simulation of transcatheter aortic valve replacement (TAVR) in bicuspid aortic valve (BAV) morphology.BackgroundPatient-specific computer simulation of TAVR in BAV may predict important clinical outcomes, such as paravalvular regurgitation and conduction disturbance.MethodsBetween May 2018 and April 2019, all patients who were referred for TAVR who had BAV identified on work-up cardiac multidetector computed tomographic imaging prospectively underwent patient-specific computer simulation with a self-expanding transcatheter heart valve (THV) using TAVIguide technology.ResultsNine patients were included in the study. Sievers classification was type 0 in 2 patients and type 1 in 7 patients. The simulations altered the treatment strategy in 8 patients (89%). The simulations suggested moderate to severe paravalvular regurgitation in 3 patients, who were referred for consideration of surgery. The remaining 6 patients underwent TAVR with a self-expanding THV. In 5 of these patients (83%), THV size and/or implantation depth was altered to minimize paravalvular regurgitation and/or conduction disturbance. In 1 patient, simulations suggested significant conduction disturbance after TAVR, and a permanent pacemaker was implanted before the procedure. Following treatment, all 9 patients had no to mild paravalvular regurgitation. The patient who had a pre-procedure permanent pacemaker implanted became pacing dependent, with underlying third-degree atrioventricular block.ConclusionsPatient-specific computer simulation of TAVR in BAV can be used to identify those patients where TAVR may be associated with unfavorable clinical outcomes. Patient-specific computer simulation may be useful to guide THV sizing and positioning for potential favorable clinical outcomes.  相似文献   

3.
BackgroundThe latest iterations of devices for transcatheter aortic valve replacement (TAVR) have brought refinements to further improve patient outcomes.ObjectivesThis study sought to compare early outcomes of patients undergoing TAVR with the self-expanding (SE) Evolut PRO/PRO+ (Medtronic, Inc) or balloon-expandable (BE) Sapien 3 ULTRA (Edwards Lifesciences) devices.MethodsThe OPERA-TAVI (Comparative Analysis of Evolut PRO vs Sapien 3 Ultra Valves for Transfemoral Transcatheter Aortic Valve Implantation) registry collected data from 14 high-volume centers worldwide on patients undergoing TAVR with SE or BE devices. After excluding patients who were not eligible for both devices, patients were compared using 1:1 propensity score matching. The primary efficacy and safety outcomes were Valve Academic Research Consortium-3 device success and early safety, respectively.ResultsAmong 2,241 patients eligible for the present analysis, 683 pairs of patients were matched. The primary efficacy outcome did not differ between patients receiving SE or BE transcatheter aortic valves (SE: 87.4% vs BE: 85.9%; P = 0.47), but the BE device recipients showed a higher rate of the primary safety outcome (SE: 69.1% vs BE: 82.6%; P < 0.01). This finding was driven by the higher rates of permanent pacemaker implantation (SE: 17.9% vs BE: 10.1%; P < 0.01) and disabling stroke (SE: 2.3% vs BE: 0.7%; P = 0.03) in SE device recipients. On post-TAVR echocardiography, the rate of moderate to severe paravalvular regurgitation was similar between groups (SE: 3.2% vs BE: 2.3%; P = 0.41), whereas lower mean transvalvular gradients were observed in the SE cohort (median SE: 7.0 vs BE: 12.0 mm Hg; P < 0.01).ConclusionsThe OPERA-TAVI registry showed that SE and BE devices had comparable Valve Academic Research Consortium-3 device success rates, but the BE device had a higher rate of early safety. The higher permanent pacemaker implantation and disabling stroke rates in SE device recipients drove this composite endpoint.  相似文献   

4.
ObjectivesThe aim of this study was to compare outcomes after transcatheter aortic valve replacement (TAVR) with the SAPIEN 3 Ultra (Ultra) and SAPIEN 3 (S3) transcatheter heart valves (THVs).BackgroundThe latest generation balloon-expandable Ultra THV incorporates new technical features and might improve outcomes following TAVR.MethodsThis registry included all consecutive patients who underwent TAVR with either the Ultra or S3 between January 2014 and January 2020. One-to-one propensity score matching was performed to account for differences in baseline characteristics. In-hospital and 30-day Valve Academic Research Consortium-2–defined outcomes were investigated.ResultsA total of 310 patients (n = 155 Ultra, n = 155 S3) were included. There were no significant differences in baseline characteristics after propensity score matching. Procedures were significantly more often performed under conscious sedation with Ultra compared with S3 (97.4% vs. 71.6%; p < 0.001). Pre-dilatation was more frequent with S3 compared with Ultra (85.2% vs. 42.6%; p < 0.001). In-hospital outcomes, including device success (91.6% vs. 95.5%; p = 0.165), major vascular complications (12.3% vs. 11.0%; p = 0.723), and new pacemaker implantation (5.8% vs. 4.5%; p = 0.608), were comparable between S3 and Ultra patients, respectively. Post-procedural mean transprosthetic gradients (13.2 ± 5.7 mm Hg vs. 13.1 ± 4.7 mm Hg; p = 0.829) and rate of moderate or greater paravalvular leakage (PVL) (1.3% vs. 2.7%; p = 0.414) were comparable, whereas mild PVL was more frequent with S3 compared with Ultra (43.0% vs. 18.7%; p < 0.001).ConclusionsDevice success rates were high with both balloon-expandable THVs, with overall low rates of adverse events up to 30 days after TAVR. Despite a lower frequency of pre-dilatation, significant reduction of mild PVL confirms improved annular sealing properties of the novel Ultra THV.  相似文献   

5.
ObjectivesThe aim of this study was to report the outcomes of valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) at 5 years.BackgroundTAVR for degenerated surgical bioprostheses in patients at high risk for reoperative surgery is an important treatment option that may delay or obviate the need for surgical intervention; however, long-term outcomes of this procedure are unknown.MethodsThe PARTNER (Placement of Aortic Transcatheter Valves) 2 ViV and continued access registries prospectively enrolled patients with failed surgical bioprostheses at high risk for reoperation. Five-year clinical and echocardiographic follow-up data were obtained in 95.9% of patients.ResultsIn 365 (96 registry and 269 continued access) patients, the mean age was 78.9 ± 10.2 years, the mean Society of Thoracic Surgeons predicted risk of surgical mortality score was 9.1 ± 4.7%, and New York Heart Association functional class was III or IV in 90.4%. At 5 years, the Kaplan-Meier rates of all-cause mortality and any stroke were 50.6% and 10.5%, respectively. Using Valve Academic Research Consortium 3 definitions, the incidence of structural valve deterioration, related hemodynamic valve deterioration, or bioprosthetic valve failure at 5 years was 6.6%. Aortic valve re-replacement was performed in 6.3% (n = 14), the majority of which was due to stenosis (n = 6) and combined aortic insufficiency/paravalvular regurgitation (n = 3). The mean gradient, Doppler velocity index, paravalvular regurgitation, and quality of life measured by Kansas City Cardiomyopathy Questionnaire scores in survivors remained stable from 30 days postprocedure through 5 years.ConclusionsAt the 5-year follow-up, TAVR for bioprosthetic aortic valve failure in high surgical risk patients was associated with sustained improvement in clinical and echocardiographic outcomes.  相似文献   

6.
BackgroundIt is unknown whether the sex difference whereby female transcatheter aortic valve replacement (TAVR) candidates had a lower risk profile, a higher incidence of in-hospital complications, but more favorable short- and long-term survival observed in tricuspid cohorts undergoing TAVR would persist in patients with bicuspid aortic valves (BAVs).ObjectivesThe aim of this study was to reexamine the impact of sex on outcomes following TAVR in patients with BAVs.MethodsIn this single-center study, patients with BAVs undergoing TAVR for severe aortic stenosis from 2012 to 2021 were retrospectively included. Baseline characteristics, aortic root anatomy, and in-hospital and 1-year valve hemodynamic status and survival were compared between sexes.ResultsA total of 510 patients with BAVs were included. At baseline, women presented with fewer comorbidities. Men had a greater proportion of Sievers type 1 BAV, higher calcium volumes (549.2 ± 408.4 mm3 vs 920.8 ± 654.3 mm3; P < 0.001), and larger aortic root structures. Women experienced more vascular complications (12.9% vs 4.9%; P = 0.002) and bleeding (11.1% vs 5.3%; P = 0.019) and higher residual gradients (16.9 ± 7.7 mm Hg vs 13.2 ± 6.4 mm Hg; P < 0.001), while men were more likely to undergo second valve implantations during index TAVR (6.3% vs 15.9%; P = 0.001). Death at 1 year was not significantly different between sexes (HR: 1.15; 95% CI: 0.56-2.35; P = 0.70). Bleeding (adjusted HR: 4.62; 95% CI: 1.51-14.12; P = 0.007) was the single independent predictor of 1-year death for women.ConclusionsIn patients with BAVs undergoing TAVR, women presented with fewer comorbidities, while men had a greater proportion of type 1 BAV, more calcification, and larger aortic roots. In-hospital outcomes favored men, with fewer complications except for the need for second valve implantation, but 1-year survival was comparable between sexes.  相似文献   

7.
ObjectivesA large comprehensive analysis of transcatheter aortic valve replacement (TAVR) was performed for failed stentless bioprostheses.BackgroundValve-in-valve (ViV) transcatheter aortic replacement (TAVR) is an alternative to redo surgery for patients with a failing aortic bioprosthesis.MethodsUnadjusted outcome data were collected from the VIVID (Valve-in-Valve International Data) registry between 2007 and 2016 from a total of 1,598 aortic ViV procedures (291 stentless, 1,307 stented bioprostheses).ResultsBioprosthetic failure was secondary to aortic regurgitation in 56% of stentless and 20% stented devices (p < 0.001). ViV-TAVR access was transfemoral in 71.1% stentless and 74.2% stented ViV-TAVR. Self-expanding devices were more frequently used in stentless ViV-TAVR (56.0% vs. 39.9%; p = 0.05), but there was no difference between balloon-expanding and self-expanding TAVR devices for stented ViV-TAVR (48.6% vs. 45.1%). The degree of oversizing for all mechanisms of bioprosthesis failure was 9 ± 10% for stentless ViV-TAVR vs. 6 ± 9% for stented ViV-TAVR (and 8 ± 10% for stentless ViV-TAVR vs. 3 ± 9% for stented ViV-TAVR in patients with predominant aortic regurgitation; both p < 0.001). Initial device malposition (10.3% vs. 6.2%; p = 0.014), second transcatheter device (7.9% vs. 3.4%), coronary obstruction (6.0% vs. 1.5%), and paravalvular leak occurred more frequently in stentless ViV-TAVR (all p < 0.001). Hospital stay duration (median 7 days) was no different, and 30-day (6.6% vs. 4.4%; p = 0.12) and 1-year mortality year (15.8% vs. 12.6%; p = 0.15) were numerically higher, but not statistically different, after stentless ViV-TAVR.ConclusionsStentless ViV-TAVR is associated with greater periprocedural complications (initial device malposition, second transcatheter device, coronary obstruction, paravalvular leak), but no difference in 30-day and 1-year outcome.  相似文献   

8.
ObjectivesThe aim of this study was to assess the evolution of early outcomes for 3 iterative self-expanding transcatheter aortic valves.BackgroundOver the past decade there have been rapid advancements in transcatheter aortic valve replacement (TAVR) technologies, including 3 generations of supra-annular self-expanding transcatheter systems.MethodsData from the Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry for patients undergoing TAVR with CoreValve, Evolut R, or Evolut PRO valves to treat tricuspid aortic stenosis between January 2014 and September 2017 were obtained. Patient risk and echocardiographic data are site reported. Valves analyzed included 23-, 26-, and 29-mm sizes to fit 18- to 26-mm annular diameters. Propensity score matching was performed using the Evolut PRO group as the common reference.ResultsOf 18,874 patients undergoing TAVR at 381 centers, 5,514 patients were implanted with CoreValve, 11,295 with Evolut R, and 2,065 with Evolut PRO valves. At 30 days, there were significantly fewer patients with more than mild aortic regurgitation for the unmatched (7.8% CoreValve, 5.2% Evolut R, and 2.8% Evolut PRO; p < 0.001) and matched populations (8.3% CoreValve, 5.4% Evolut R, and 3.4% Evolut PRO; p = 0.032). The mean aortic valve gradients at 30 days in the matched populations were <8 mm Hg for all 3 valves (7.3 mm Hg CoreValve, 7.5 mm Hg Evolut R, 7.2 mm Hg Evolut PRO).ConclusionsAdvancements in transcatheter valve technologies and expanding indications for TAVR have resulted in improved outcomes for patients undergoing TAVR in the United States with self-expanding, supra-annular valves. In particular, the addition of an outer pericardial tissue wrap designed to enhance sealing at the level of the aortic annulus has resulted in very low rates of significant aortic regurgitation while maintaining excellent hemodynamic status.  相似文献   

9.
ObjectivesThe aim of this study was to evaluate and compare the outcomes of transcatheter self-expandable prostheses in patients with small annuli.BackgroundTranscatheter aortic heart valves appear to have better performance than surgical valves in terms of prosthesis-patient mismatch, especially in patients with aortic stenosis with small aortic annuli.MethodsTAVI-SMALL (International Multicenter Registry to Evaluate the Performance of Self-Expandable Valves in Small Aortic Annuli) is a retrospective registry of patients with severe aortic stenosis and small annuli (annular perimeter <72 mm or area <400 mm2 on computed tomography) treated with transcatheter self-expandable valves (n = 859; Evolut R, n = 397; Evolut PRO, n = 84; ACURATE, n = 201; Portico, n = 177). Primary endpoints were post-procedural mean aortic gradient, indexed effective orifice area, and rate of severe prosthesis-patient mismatch.ResultsPre-discharge gradients were consistently low in every group, with a slight benefit with the Evolut R (8.1 mm Hg; 95% confidence interval [CI]: 7.7 to 8.5 mm Hg) and Evolut PRO (6.9 mm Hg; 95% CI: 6.3 to 7.6 mm Hg) compared with the ACURATE (9.6 mm Hg; 95% CI: 8.9 to 10.2 mm Hg) and Portico (8.9 mm Hg; 95% CI: 8.2 to 9.6 mm Hg) groups (p < 0.001). Mean indexed effective orifice area was 1.04 cm2/m2 (95% CI: 1.01 to 1.08 cm2/m2) with a trend toward lower values with the Portico. No significant differences were reported in terms of severe prosthesis-patient mismatch (overall rate 9.4%; p = 0.134), permanent pacemaker implantation (15.6%), and periprocedural and 1-year adverse events. Pre-discharge more than mild paravalvular leaks were significantly more common with the Portico (19.2%) and less common with the Evolut PRO (3.6%) compared with the Evolut R (11.8%) and ACURATE (9%) groups.ConclusionsTranscatheter self-expandable valves showed optimal clinical and echocardiographic results in patients with small aortic annuli, although supra-annular functioning transcatheter heart valves seemed to slightly outperform intra-annular functioning ones. The role of transcatheter aortic valve replacement with self-expandable valves for the treatment of aortic stenosis in patients with small annuli needs to be confirmed in larger trials.  相似文献   

10.
ObjectivesThe aim of this study was to evaluate the short-term safety and efficacy of transcatheter aortic valve replacement (TAVR) with the LOTUS Edge system.BackgroundThe LOTUS Edge system was commercially re-released in April 2019. The authors report the first European experience with this device.MethodsA multicenter, single-arm, retrospective registry was initiated to evaluate short-term clinical outcomes. Included cases are the first experience with this device and new implantation technique in Europe. Clinical, echocardiographic, and computed tomographic data were analyzed. Endpoints were defined according to Valve Academic Research Consortium-2 and were site reported.ResultsBetween April and November 2019, 286 consecutive patients undergoing TAVR with the LOTUS Edge system at 18 European centers were included. The mean age and Society of Thoracic Surgeons score were 81.2 ± 6.9 years and 5.2 ± 5.4%, respectively. Nearly one-half of all patients (47.9%) were considered to have complex anatomy. Thirty-day major adverse events included death (2.4% [n = 7]) and stroke (3.5% [n = 10]). After TAVR, the mean aortic valve area was 1.9 ± 0.9 cm2, and the mean transvalvular gradient was 11.9 ± 5.7 mm Hg. None or trace paravalvular leak (PVL) occurred in 84.4% and moderate PVL in 2.0%. There were no cases of severe PVL. New permanent pacemaker (PPM) implantation was required in 25.9% among all patients and 30.8% among PPM-naive patients.ConclusionsEarly experience with the LOTUS Edge system demonstrated satisfactory short-term safety and efficacy, favorable hemodynamic data, and very low rates of PVL in an anatomically complex cohort. New PPM implantation remained high. Further study will evaluate if increasing operator experience with the device and new implantation technique can reduce the incidence of PPM implantation.  相似文献   

11.
BackgroundSelf-expanding transcatheter heart valves (THVs) are associated with better echocardiographic hemodynamic performance than balloon-expandable THVs and are considered preferable in patients with small annuli.ObjectivesThis study sought to compare 5-year outcomes between self-expanding vs balloon-expandable THVs in severe aortic stenosis (AS) patients with small annuli.MethodsConsecutive severe AS patients with an aortic valve annulus area <430 mm2 who underwent transcatheter aortic valve replacement (TAVR) with either the CoreValve Evolut (Medtronic) or SAPIEN (Edwards Lifesciences) THV between 2012 and 2021 were enrolled from the Bern TAVI registry. A 1:1 propensity-matched analysis was performed to account for baseline differences between groups.ResultsA total of 723 patients were included, and propensity score matching resulted in 171 pairs. Technical success was achieved in over 85% of both groups with no significant difference. Self-expanding THVs were associated with a lower transvalvular gradient (8.0 ± 4.8 mm Hg vs 12.5 ± 4.5 mm Hg; P < 0.001), a larger effective orifice area (1.81 ± 0.46 cm2 vs 1.49 ± 0.42 cm2; P < 0.001), and a lower incidence of prosthesis-patient mismatch (19.7% vs 51.8%; P < 0.001) than balloon-expandable THVs. At 5 years, there were no significant differences in mortality (50.4% vs 39.6%; P = 0.269) between groups. Disabling stroke occurred more frequently in patients with a self-expanding THV than those with a balloon-expandable THV (6.6% vs 0.6%; P = 0.030). Similar results were obtained using inverse probability of treatment weighting in the Bern TAVI registry and the nationwide Swiss TAVI registry.ConclusionsThe echocardiographic hemodynamic advantage of self-expanding THVs was not associated with better clinical outcomes compared with balloon-expandable THVs up to 5 years in patients with small annuli. (Swiss TAVI Registry; NCT01368250)  相似文献   

12.
ObjectivesThe aim of this study was to assess the outcomes of severe prosthesis-patient mismatch (PPM) in the TVT (Transcatheter Valve Therapy) Registry in patients undergoing supra-annular transcatheter aortic valve replacement (TAVR) for de novo stenosis or failed surgical bioprostheses (transcatheter aortic valve [TAV]–in–surgical aortic valve [SAV]).BackgroundSevere PPM has been associated with adverse outcomes following TAVR, yet the clinical outcome of severe PPM after supra-annular TAVR is largely unknown.MethodsSupra-annular TAVR was performed in patients enrolled in the TVT Registry with de novo stenosis (n = 42,174) or TAV-in-SAV (n = 5,446). Valve Academic Research Consortium-3 criteria were used to define severe PPM. The clinical impact of severe PPM on 1-year mortality and valve-related readmission was assessed using multivariate regression. A generalized linear mixed model was used to evaluate predictors of severe PPM.ResultsSevere PPM was found in 5.3% of patients undergoing de novo TAVR and 27.0% of patients undergoing TAV-in-SAV. The presence of severe PPM was not significantly associated with 1-year mortality or valve-related readmissions in both groups. Mean aortic gradients were higher in patients with severe PPM than in those without severe PPM at 1 month (9.7 ± 5.7 mm Hg vs. 7.3 ± 4.0 mm Hg; p < 0.001) and 1 year (10.2 ± 6.4 mm Hg vs. 8.0 ± 4.3 mm Hg; p < 0.001). Pre-procedural factors, including a <20-mm aortic annulus, were positive predictors of severe PPM in patients undergoing de novo TAVR (area under the curve = 0.795) and TAV-in-SAV (area under the curve = 0.764).ConclusionsSevere PPM after supra-annular TAVR was not associated with increased 1-year mortality or valve-related readmissions. Longer-term follow-up is needed to determine if higher residual gradients in patients with severe PPM predict long-term outcomes. (STS/ACC Transcatheter Valve Therapy Registry [TVT Registry]; NCT01737528)  相似文献   

13.
ObjectivesThis study aimed to systematically assess the importance of left ventricular outflow tract (LVOT) calcification on procedural outcomes and device performances with contemporary transcatheter heart valve (THV) systems.BackgroundLVOT calcification has been associated with adverse clinical outcomes after transcatheter aortic valve replacement (TAVR). However, the available evidence is limited to observational data with modest numbers and incomplete assessment of the effect of the different THV systems.MethodsIn a retrospective analysis of a prospective single-center registry, LVOT calcification was assessed in a semiquantitative fashion. Moderate or severe LVOT calcification was documented in the presence of 2 nodules of calcification, or 1 extending >5 mm in any direction, or covering >10 % of the perimeter of the LVOT.ResultsAmong 1,635 patients undergoing TAVR between 2007 and 2018, moderate or severe LVOT calcification was found in 407 (24.9%). Patients with moderate or severe LVOT calcification had significantly higher incidences of annular rupture (2.3% vs. 0.2%; p < 0.001), bailout valve-in-valve implantation (2.9% vs. 0.8%; p = 0.004), and residual aortic regurgitation (11.1% vs. 6.3%; p = 0.002). Balloon-expandable valves conferred a higher risk of annular rupture in the presence of moderate or severe LVOT calcification (4.0% vs. 0.4%; p = 0.002) as compared with the other valve designs. There was no significant interaction of valve design or generation and LVOT calcification with regard to the occurrence of bailout valve-in-valve implantation and residual aortic regurgitation.ConclusionsModerate or severe LVOT calcification confers increased risks of annular rupture, residual aortic regurgitation, and implantation of a second valve. The risk of residual aortic regurgitation is consistent across valve designs and generations. (SWISS TAVI Registry; NCT01368250)  相似文献   

14.
BackgroundTranscatheter aortic valve replacement (TAVR) use is increasing in patients with longer life expectancy, yet robust data on the durability of transcatheter heart valves (THVs) are limited. Redo-TAVR may play a key strategy in treating patients in whom THVs fail.ObjectivesThe authors sought to examine outcomes following redo-TAVR.MethodsThe Redo-TAVR registry collected data on consecutive patients who underwent redo-TAVR at 37 centers. Patients were classified as probable TAVR failure or probable THV failure if they presented within or beyond 1 year of their index TAVR, respectively.ResultsAmong 63,876 TAVR procedures, 212 consecutive redo-TAVR procedures were identified (0.33%): 74 within and 138 beyond 1 year of the initial procedure. For these 2 groups, TAVR-to-redo-TAVR time was 68 (38 to 154) days and 5 (3 to 6) years. The indication for redo-TAVR was THV stenosis in 12 (16.2%) and 51 (37.0%) (p = 0.002) and regurgitation or combined stenosis–regurgitation in 62 (83.8%) and 86 (62.3%) (p = 0.028), respectively. Device success using VARC-2 criteria was achieved in 180 patients (85.1%); most failures were attributable to high residual gradients (14.1%) or regurgitation (8.9%). At 30-day and 1-year follow-up, residual gradients were 12.6 ± 7.5 mm Hg and 12.9 ± 9.0 mm Hg; valve area 1.63 ± 0.61 cm2 and 1.51 ± 0.57 cm2; and regurgitation ≤mild in 91% and 91%, respectively. Peri-procedural complication rates were low (3 stroke [1.4%], 7 valve malposition [3.3%], 2 coronary obstruction [0.9%], 20 new permanent pacemaker [9.6%], no mortality), and symptomatic improvement was substantial. Survival at 30 days was 94.6% and 98.5% (p = 0.101) and 83.6% and 88.3% (p = 0.335) at 1 year for patients presenting with early and late valve dysfunction, respectively.ConclusionsRedo-TAVR is a relatively safe and effective option for selected patients with valve dysfunction after TAVR. These results are important for applicability of TAVR in patients with long life expectancy in whom THV durability may be a concern.  相似文献   

15.
ObjectivesThe aim of this study was to compare the feasibility, safety, and clinical outcomes of transcatheter aortic valve replacement (TAVR) in bicuspid aortic valve (BAV) versus tricuspid aortic valve (TAV) stenosis.BackgroundAt present, limited observational data exist supporting TAVR in the context of bicuspid anatomy.MethodsPrimary endpoints were 1-year survival and device success. Secondary endpoints included moderate to severe paravalvular leak (PVL) and a composite endpoint of periprocedural complications; incidence rates of individual procedural endpoints were also explored individually.ResultsIn the main analysis, 17 studies and 181,433 patients undergoing TAVR were included, of whom 6,669 (0.27%) had BAV. A secondary analysis of 7,071 matched subjects with similar baseline characteristics was also performed. Device success and 1-year survival rates were similar between subjects with BAV and those with TAV (97% vs 94% [P = 0.55] and 91.3% vs 90.8% [P = 0.22], respectively). In patients with BAV, a trend toward a higher risk for periprocedural complications was observed in our main analysis (risk ratio [RR]: 1.12; 95% CI: 0.99-1.27; P = 0.07) but not in the matched population secondary analysis (RR: 1.00; 95% CI: 0.81-1.24; P = 0.99). The risk for moderate to severe PVL was higher in subjects with BAV (RR: 1.42; 95% CI: 1.29-1.58; P < 0.0001) as well as the incidence of cerebral ischemic events (2.4% vs 1.6%; P = 0.015) and of annular rupture (0.3% vs 0.02%; P = 0.014) in matched subjects.ConclusionsTAVR is a feasible option among selected patients with BAV anatomy, but the higher rates of moderate to severe PVL, annular rupture, and cerebral ischemic events observed in the BAV group warrant caution and further evidence.  相似文献   

16.
ObjectivesThe aim of this study was to evaluate device success of transcatheter aortic valve replacement (TAVR) using new-generation balloon-expandable prostheses with or without balloon aortic valvuloplasty (BAV).BackgroundRandomized studies are lacking comparing TAVR without BAV against the conventional technique of TAVR with BAV.MethodsDIRECTAVI (Direct Transcatheter Aortic Valve Implantation) was an open-label noninferiority study that randomized patients undergoing TAVR using the Edwards SAPIEN 3 valve with or without prior balloon valvuloplasty. The primary endpoint was the device success rate according to Valve Academic Research Consortium-2 criteria, which was evaluated using a 7% noninferiority margin. The secondary endpoint included procedural and 30-day adverse events.ResultsDevice success was recorded for 184 of 236 included patients (78.0%). The rate of device success in the direct implantation group (n = 97 [80.2%]) was noninferior to that in the BAV group (n = 87 [75.7%]) (mean difference 4.5%; 95% confidence interval: −4.4% to 13.4%; p = 0.02 for noninferiority). No severe prosthesis-patient mismatch or severe aortic regurgitation occurred in any group. In the direct implantation group, 7 patients (5.8%) required BAV to cross the valve. Adverse events were related mainly to pacemaker implantation (20.9% in the BAV group vs. 19.0% in the direct implantation group; p = 0.70). No significant difference was found between the 2 strategies in duration of procedure, contrast volume, radiation exposure, or rate of post-dilatation.ConclusionsDirect TAVR without prior BAV was noninferior to the conventional strategy using BAV with new-generation balloon-expandable valves, but without procedural simplification. BAV was needed to cross the valve in a few patients, suggesting a need for upstream selection on the basis of patient anatomy. (TAVI Without Balloon Predilatation [of the Aortic Valve] SAPIEN 3 [DIRECTAVI]; NCT02729519)  相似文献   

17.
ObjectivesThe aim of this study was to evaluate clinical outcomes and transcatheter heart valve hemodynamic parameters after transcatheter aortic valve replacement (TAVR) in low-risk patients with bicuspid aortic stenosis (AS).BackgroundTAVR is approved for low-risk patients in the United States. However, patients with bicuspid AS were excluded from the randomized cohorts of the pivotal low-risk trials.MethodsThe LRT (Low Risk TAVR) trial was an investigator-initiated, prospective, multicenter study and was the first and only U.S. Food and Drug Administration–approved investigational device exemption trial to evaluate the feasibility of TAVR with either balloon-expandable or self-expanding valves in low-risk patients with bicuspid AS. The primary endpoint was all-cause mortality at 30 days. Baseline and follow-up echocardiography and computed tomography to detect leaflet thickening were analyzed in an independent core laboratory.ResultsSixty-one low-risk patients with symptomatic, severe AS and bicuspid aortic valves (78.3% Sievers type 1 morphology) underwent TAVR at 6 centers from 2016 to 2019. The mean age was 68.6 years, and 42.6% were men. At 30 days, there was zero mortality and no disabling strokes. The rate of new permanent pacemaker implantation was 13.1%; just 1 patient had a moderate paravalvular leak at 30 days. Hypoattenuated leaflet thickening was observed in 10% of patients at 30 days.ConclusionsTAVR appears to be safe in patients with bicuspid AS, with short length of hospital stay, zero mortality, and no disabling strokes at 30 days. Subclinical leaflet thrombosis was observed in a minority of patients at 30 days but did not appear to be associated with clinical events.  相似文献   

18.

Objectives

The aim of this study was to determine factors affecting paravalvular leak (PVL) in transcatheter aortic valve replacement (TAVR) with the Edwards SAPIEN 3 (S3) valve in extremely large annuli.

Background

The largest recommended annular area for the 29-mm S3 is 683 mm2. However, experience with S3 TAVR in annuli >683 mm2 has not been widely reported.

Methods

From December 2013 to July 2017, 74 patients across 16 centers with mean area 721 ± 38 mm2 (range: 684 to 852 mm2) underwent S3 TAVR. The transfemoral approach was used in 95%, and 39% were under conscious sedation. Patient, anatomic, and procedural characteristics were retrospectively analyzed. Valve Academic Research Consortium–2 outcomes were reported.

Results

Procedural success was 100%, with 2 deaths, 1 stroke, and 2 major vascular complications at 30 days. Post-dilatation occurred in 32%, with final balloon overfilling (1 to 5 ml extra) in 70% of patients. Implantation depth averaged 22.3 ± 12.4% at the noncoronary cusp and 20.7 ± 9.9% at the left coronary cusp. New left bundle branch block occurred in 17%, and 6.3% required new permanent pacemakers. Thirty-day echocardiography showed mild PVL in 22.3%, 6.9% moderate, and none severe. There was no annular rupture or coronary obstruction. Mild or greater PVL was associated with larger maximum annular and left ventricular outflow tract (LVOT) diameters, larger LVOT area and perimeter, LVOT area greater than annular area, and higher annular eccentricity.

Conclusions

TAVR with the 29-mm S3 valve beyond the recommended range by overexpansion is safe, with acceptable PVL and pacemaker rates. Larger LVOTs and more eccentric annuli were associated with more PVL. Longer term follow-up will be needed to determine durability of S3 TAVR in this population.  相似文献   

19.
ObjectivesThe aim of this study was to assess the added value and predictive power of the TAVIguide (Added Value of Patient-Specific Computer Simulation in Transcatheter Aortic Valve Implantation) software in clinical practice.BackgroundOptimal outcome after transcatheter aortic valve replacement (TAVR) may become more important as TAVR shifts toward low-risk patients. Patient-specific computer simulation is able to provide prediction of outcome after TAVR. Its clinical role and validation of accuracy, however, have not yet been studied prospectively.MethodsA prospective, observational, multicenter study was conducted among 80 patients with severe aortic stenosis treated with the Evolut R valve. Simulation was performed in 42 patients and no simulation in 38. A comparison between the valve size (decision 1) and target depth of implantation selected by the operator on the basis of multislice computed tomography and the valve size (decision 2) and target depth of implantation selected after simulation were the primary endpoints. Predictive power was examined by comparing the simulated and observed degree of aortic regurgitation.ResultsDecision 2 differed from decision 1 in 1 of 42 patients because of predicted paravalvular leakage, and changes in valve type occurred in 2 of 42. In 39 of 42 patients, decisions 1 and 2 were similar. Target depth of implantation differed in 7 of 42 patients after simulation (lower in 4 and higher in 3). In 16 of 42 patients, simulation affected the TAVR procedure; in 9, the operator avoided additional measures to achieve the target depth of implantation, and in 7 patients, additional measures were performed. There was a trend toward a higher degree of predicted than observed aortic regurgitation (17.5 vs. 12 ml/s; p = 0.13).ConclusionsPatient-specific computer simulation did not affect valve size selection but did affect the selection of the target depth of implantation and the execution of TAVR to achieve the desired target depth of implantation.  相似文献   

20.
BackgroundThe randomized SOLVE-TAVI (compariSon of secOnd-generation seLf-expandable vs. balloon-expandable Valves and gEneral vs. local anesthesia in Transcatheter Aortic Valve Implantation) trial compared newer-generation self-expanding valves (SEV) and balloon-expandable valves (BEV) as well as local anesthesia with conscious sedation (CS) and general anesthesia (GA) in patients undergoing transfemoral transcatheter aortic valve replacement (TAVR). Both strategies showed similar outcomes at 30 days.ObjectivesThe purpose of this study was to compare clinical outcomes during 1-year follow-up in the randomized SOLVE-TAVI trial.MethodsUsing a 2 × 2 factorial design 447 intermediate- to high-risk patients with severe, symptomatic aortic stenosis were randomly assigned to transfemoral TAVR using either the SEV (Evolut R, Medtronic Inc., Minneapolis, Minnesota) or the BEV (Sapien 3, Edwards Lifesciences, Irvine, California) as well as CS or GA at 7 sites.ResultsIn the valve-comparison strategy, rates of the combined endpoint of all-cause mortality, stroke, moderate or severe paravalvular leakage, and permanent pacemaker implantation were similar between the BEV and SEV group (n = 84, 38.3% vs. n = 87, 40.4%; hazard ratio: 0.94; 95% confidence interval: 0.70 to 1.26; p = 0.66) at 1 year. Regarding the anesthesia comparison, the combined endpoint of all-cause mortality, stroke, myocardial infarction, and acute kidney injury occurred with similar rates in the GA and CS groups (n = 61, 25.7% vs. n = 54, 23.8%; hazard ratio: 1.09; 95% confidence interval: 0.76 to 1.57; p = 0.63).ConclusionsIn intermediate- to high-risk patients undergoing transfemoral TAVR, newer-generation SEV and BEV as well as CS and GA showed similar clinical outcomes at 1 year using a combined clinical endpoint. (SecOnd-generation seLf-expandable Versus Balloon-expandable Valves and gEneral Versus Local Anesthesia in TAVI [SOLVE-TAVI]; NCT02737150)  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号