首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
ObjectivesThe aim of this study was to prospectively evaluate the clinical use of patient-specific computer simulation of transcatheter aortic valve replacement (TAVR) in bicuspid aortic valve (BAV) morphology.BackgroundPatient-specific computer simulation of TAVR in BAV may predict important clinical outcomes, such as paravalvular regurgitation and conduction disturbance.MethodsBetween May 2018 and April 2019, all patients who were referred for TAVR who had BAV identified on work-up cardiac multidetector computed tomographic imaging prospectively underwent patient-specific computer simulation with a self-expanding transcatheter heart valve (THV) using TAVIguide technology.ResultsNine patients were included in the study. Sievers classification was type 0 in 2 patients and type 1 in 7 patients. The simulations altered the treatment strategy in 8 patients (89%). The simulations suggested moderate to severe paravalvular regurgitation in 3 patients, who were referred for consideration of surgery. The remaining 6 patients underwent TAVR with a self-expanding THV. In 5 of these patients (83%), THV size and/or implantation depth was altered to minimize paravalvular regurgitation and/or conduction disturbance. In 1 patient, simulations suggested significant conduction disturbance after TAVR, and a permanent pacemaker was implanted before the procedure. Following treatment, all 9 patients had no to mild paravalvular regurgitation. The patient who had a pre-procedure permanent pacemaker implanted became pacing dependent, with underlying third-degree atrioventricular block.ConclusionsPatient-specific computer simulation of TAVR in BAV can be used to identify those patients where TAVR may be associated with unfavorable clinical outcomes. Patient-specific computer simulation may be useful to guide THV sizing and positioning for potential favorable clinical outcomes.  相似文献   

2.
ObjectivesThis study aimed to systematically assess the importance of left ventricular outflow tract (LVOT) calcification on procedural outcomes and device performances with contemporary transcatheter heart valve (THV) systems.BackgroundLVOT calcification has been associated with adverse clinical outcomes after transcatheter aortic valve replacement (TAVR). However, the available evidence is limited to observational data with modest numbers and incomplete assessment of the effect of the different THV systems.MethodsIn a retrospective analysis of a prospective single-center registry, LVOT calcification was assessed in a semiquantitative fashion. Moderate or severe LVOT calcification was documented in the presence of 2 nodules of calcification, or 1 extending >5 mm in any direction, or covering >10 % of the perimeter of the LVOT.ResultsAmong 1,635 patients undergoing TAVR between 2007 and 2018, moderate or severe LVOT calcification was found in 407 (24.9%). Patients with moderate or severe LVOT calcification had significantly higher incidences of annular rupture (2.3% vs. 0.2%; p < 0.001), bailout valve-in-valve implantation (2.9% vs. 0.8%; p = 0.004), and residual aortic regurgitation (11.1% vs. 6.3%; p = 0.002). Balloon-expandable valves conferred a higher risk of annular rupture in the presence of moderate or severe LVOT calcification (4.0% vs. 0.4%; p = 0.002) as compared with the other valve designs. There was no significant interaction of valve design or generation and LVOT calcification with regard to the occurrence of bailout valve-in-valve implantation and residual aortic regurgitation.ConclusionsModerate or severe LVOT calcification confers increased risks of annular rupture, residual aortic regurgitation, and implantation of a second valve. The risk of residual aortic regurgitation is consistent across valve designs and generations. (SWISS TAVI Registry; NCT01368250)  相似文献   

3.
ObjectivesThe aim of this study was to evaluate device success of transcatheter aortic valve replacement (TAVR) using new-generation balloon-expandable prostheses with or without balloon aortic valvuloplasty (BAV).BackgroundRandomized studies are lacking comparing TAVR without BAV against the conventional technique of TAVR with BAV.MethodsDIRECTAVI (Direct Transcatheter Aortic Valve Implantation) was an open-label noninferiority study that randomized patients undergoing TAVR using the Edwards SAPIEN 3 valve with or without prior balloon valvuloplasty. The primary endpoint was the device success rate according to Valve Academic Research Consortium-2 criteria, which was evaluated using a 7% noninferiority margin. The secondary endpoint included procedural and 30-day adverse events.ResultsDevice success was recorded for 184 of 236 included patients (78.0%). The rate of device success in the direct implantation group (n = 97 [80.2%]) was noninferior to that in the BAV group (n = 87 [75.7%]) (mean difference 4.5%; 95% confidence interval: −4.4% to 13.4%; p = 0.02 for noninferiority). No severe prosthesis-patient mismatch or severe aortic regurgitation occurred in any group. In the direct implantation group, 7 patients (5.8%) required BAV to cross the valve. Adverse events were related mainly to pacemaker implantation (20.9% in the BAV group vs. 19.0% in the direct implantation group; p = 0.70). No significant difference was found between the 2 strategies in duration of procedure, contrast volume, radiation exposure, or rate of post-dilatation.ConclusionsDirect TAVR without prior BAV was noninferior to the conventional strategy using BAV with new-generation balloon-expandable valves, but without procedural simplification. BAV was needed to cross the valve in a few patients, suggesting a need for upstream selection on the basis of patient anatomy. (TAVI Without Balloon Predilatation [of the Aortic Valve] SAPIEN 3 [DIRECTAVI]; NCT02729519)  相似文献   

4.
BackgroundSurgical aortic valve replacement and transcatheter aortic valve replacement (TAVR) are now both used to treat aortic stenosis in patients in whom life expectancy may exceed valve durability. The choice of initial bioprosthesis should therefore consider the relative safety and efficacy of potential subsequent interventions.ObjectivesThe aim of this study was to compare TAVR in failed transcatheter aortic valves (TAVs) versus surgical aortic valves (SAVs).MethodsData were collected on 434 TAV-in-TAV and 624 TAV-in-SAV consecutive procedures performed at centers participating in the Redo-TAVR international registry. Propensity score matching was applied, and 330 matched (165:165) patients were analyzed. Principal endpoints were procedural success, procedural safety, and mortality at 30 days and 1 year.ResultsFor TAV-in-TAV versus TAV-in-SAV, procedural success was observed in 120 (72.7%) versus 103 (62.4%) patients (p = 0.045), driven by a numerically lower frequency of residual high valve gradient (p = 0.095), ectopic valve deployment (p = 0.081), coronary obstruction (p = 0.091), and conversion to open heart surgery (p = 0.082). Procedural safety was achieved in 116 (70.3%) versus 119 (72.1%) patients (p = 0.715). Mortality at 30 days was 5 (3%) after TAV-in-TAV and 7 (4.4%) after TAV-in-SAV (p = 0.570). At 1 year, mortality was 12 (11.9%) and 10 (10.2%), respectively (p = 0.633). Aortic valve area was larger (1.55 ± 0.5 cm2 vs. 1.37 ± 0.5 cm2; p = 0.040), and the mean residual gradient was lower (12.6 ± 5.2 mm Hg vs. 14.9 ± 5.2 mm Hg; p = 0.011) after TAV-in-TAV. The rate of moderate or greater residual aortic regurgitation was similar, but mild aortic regurgitation was more frequent after TAV-in-TAV (p = 0.003).ConclusionsIn propensity score–matched cohorts of TAV-in-TAV versus TAV-in-SAV patients, TAV-in-TAV was associated with higher procedural success and similar procedural safety or mortality.  相似文献   

5.
ObjectivesThe aim of this study was to report the 1-year results of transcatheter aortic valve replacement (TAVR) with the Edwards SAPIEN 3 (S3) valve in extremely large annuli.BackgroundFavorable 30-day outcomes of S3 TAVR in annuli >683 mm2 have previously been reported. Pacemaker implantation rates were acceptable, and a larger left ventricular outflow tract and more eccentric annular anatomy were associated with increasing paravalvular leak.MethodsFrom December 2013 to December 2018, 105 patients across 15 centers with mean area 721.3 ± 36.1 mm2 (range 683.5 to 852.0 mm2) underwent TAVR using an S3 device. Clinical, anatomic, and procedural characteristics were analyzed. One-year survival and echocardiographic follow-up were reached in 94.3% and 82.1% of patients, respectively. Valve Academic Research Consortium-2 30-day and 1-year outcomes were reported.ResultsThe mean age was 76.9 ± 10.4 years, and Society of Thoracic Surgeons predicted risk score averaged 5.2 ± 3.4%. One-year overall mortality and stroke rates were 18.2% and 2.4%, respectively. Quality-of-life index improved from baseline to 30 days and at 1 year (p < 0.001 for both). Mild paravalvular aortic regurgitation occurred in 21.7% of patients, while moderate or greater paravalvular aortic regurgitation occurred in 4.3%. Mild and moderate or severe transvalvular aortic regurgitation occurred in 11.6% and 0%, respectively. Valve gradients remained stable at 1 year.ConclusionsS3 TAVR in annular areas >683 mm2 is feasible, with favorable mid-term outcomes.  相似文献   

6.
ObjectivesThis study sought to minimize the risk of permanent pacemaker implantation (PPMI) with contemporary repositionable self-expanding transcatheter aortic valve replacement (TAVR).BackgroundSelf-expanding TAVR traditionally carries a high risk of PPMI. Limited data exist on the use of the repositionable devices to minimize this risk.MethodsAt NYU Langone Health, 248 consecutive patients with severe aortic stenosis underwent TAVR under conscious sedation with repositionable self-expanding TAVR with a standard approach to device implantation. A detailed analysis of multiple factors contributing to PPMI was performed; this was used to generate an anatomically guided MInimizing Depth According to the membranous Septum (MIDAS) approach to device implantation, aiming for pre-release depth in relation to the noncoronary cusp of less than the length of the membranous septum (MS).ResultsRight bundle branch block, MS length, largest device size (Evolut 34 XL; Medtronic, Minneapolis, Minnesota), and implant depth > MS length predicted PPMI. On multivariate analysis, only implant depth > MS length (odds ratio: 8.04; 95% confidence interval: 2.58 to 25.04; p < 0.001) and Evolut 34 XL (odds ratio: 4.96; 95% confidence interval: 1.68 to 14.63; p = 0.004) were independent predictors of PPMI. The MIDAS approach was applied prospectively to a consecutive series of 100 patients, with operators aiming to position the device at a depth of < MS length whenever possible; this reduced the new PPMI rate from 9.7% (24 of 248) in the standard cohort to 3.0% (p = 0.035), and the rate of new left bundle branch block from 25.8% to 9% (p < 0.001).ConclusionsUsing a patient-specific MIDAS approach to device implantation, repositionable self-expanding TAVR achieved very low and predictable rates of PPMI which are significantly lower than previously reported with self-expanding TAVR.  相似文献   

7.
BackgroundStroke is one of the most common and potentially disabling complications of infective endocarditis (IE). However, scarce data exist about stroke complicating IE after transcatheter aortic valve replacement (TAVR).ObjectivesThe purpose of this study was to determine the incidence, risk factors, clinical characteristics, management, and outcomes of patients with definite IE after TAVR complicated by stroke during index IE hospitalization.MethodsData from the Infectious Endocarditis after TAVR International Registry (including 569 patients who developed definite IE following TAVR from 59 centers in 11 countries) was analyzed. Patients were divided into two groups according to stroke occurrence during IE admission (stroke [S-IE] vs. no stroke [NS-IE]).ResultsA total of 57 (10%) patients had a stroke during IE hospitalization, with no differences in causative microorganism between groups. S-IE patients exhibited higher rates of acute renal failure, systemic embolization, and persistent bacteremia (p < 0.05 for all). Previous stroke before IE, residual aortic regurgitation ≥moderate after TAVR, balloon-expandable valves, IE within 30 days after TAVR, and vegetation size >8 mm were associated with a higher risk of stroke during the index IE hospitalization (p < 0.05 for all). Stroke rate in patients with no risk factors was 3.1% and increased up to 60% in the presence of >3 risk factors. S-IE patients had higher rates of in-hospital mortality (54.4% vs. 28.7%; p < 0.001) and overall mortality at 1 year (66.3% vs. 45.6%; p < 0.001). Surgical treatment was not associated with improved outcomes in S-IE patients (in-hospital mortality: 46.2% in surgical vs. 58.1% in no surgical treatment; p = 0.47).ConclusionsStroke occurred in 1 of 10 patients with IE post-TAVR. A history of stroke, short time between TAVR and IE, vegetation size, valve prosthesis type, and residual aortic regurgitation determined an increased risk. The occurrence of stroke was associated with increased in-hospital and 1-year mortality rates, and surgical treatment failed to improve clinical outcomes.  相似文献   

8.
BackgroundSubclinical leaflet thrombosis has been reported after bioprosthetic aortic valve replacement, characterized using 4-dimensional computed tomographic imaging by hypoattenuated leaflet thickening (HALT) and reduced leaflet motion (RLM). The incidence and clinical implications of these findings remain unclear.ObjectivesThe aim of this study was to determine the frequency, predictors, and hemodynamic and clinical correlates of HALT and RLM after aortic bioprosthetic replacement.MethodsA prospective subset of patients not on oral anticoagulation enrolled in the Evolut Low Risk randomized trial underwent computed tomographic imaging 30 days and 1 year after transcatheter aortic valve replacement (TAVR) or surgery. The primary endpoint was the frequency of HALT at 30 days and 1 year, analyzed by an independent core laboratory using standardized definitions. Secondary endpoints included RLM, mean aortic gradient, and clinical events at 30 days and 1 year.ResultsAt 30 days, the frequency of HALT was 31 of 179 (17.3%) for TAVR and 23 of 139 (16.5%) for surgery; the frequency of RLM was 23 of 157 (14.6%) for TAVR and 19 of 133 (14.3%) for surgery. At 1 year, the frequency of HALT was 47 of 152 (30.9%) for TAVR and 33 of 116 (28.4%) for surgery; the frequency of RLM was 45 of 145 (31.0%) for TAVR and 30 of 111 (27.0%) for surgery. Aortic valve hemodynamic status was not influenced by the presence or severity of HALT or RLM at either time point. The rates of HALT and RLM were similar after the implantation of supra-annular, self-expanding transcatheter, or surgical bioprostheses.ConclusionsThe presence of computed tomographic imaging abnormalities of aortic bioprostheses were frequent but dynamic in the first year after self-expanding transcatheter and surgical aortic valve replacement, but these findings did not correlate with aortic valve hemodynamic status after aortic valve replacement in patients at low risk for surgery. (Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients; NCT02701283)  相似文献   

9.
ObjectivesThe aims of this study were to investigate the feasibility of coronary ostia cannulation after transcatheter aortic valve replacement (TAVR) and to assess potential predictors of coronary access impairment.BackgroundCertain data concerning the feasibility and reproducibility of coronary cannulation after TAVR are lacking.MethodsRE-ACCESS (Reobtain Coronary Ostia Cannulation Beyond Transcatheter Aortic Valve Stent) was an investigator-driven, single-center, prospective, registry-based study that enrolled consecutive patients undergoing TAVR using all commercially available devices. All patients underwent coronary angiography before and after TAVR. The primary endpoint was the rate of unsuccessful coronary ostia cannulation after TAVR. Secondary endpoints were the identification of factors associated with the inability to selectively cannulate coronary ostia after TAVR.ResultsAmong 300 patients enrolled in the RE-ACCESS study from December 2018 to January 2020, a total of 23 cases (7.7%) of unsuccessful coronary cannulation after TAVR were documented. This issue occurred in 22 of 23 cases with the use of Evolut R/PRO transcatheter aortic valves (TAVs) (17.9% vs. 0.4%; p < 0.01). In multivariate analysis, the use of Evolut R/PRO TAVs (odds ratio [OR]: 29.6; 95% confidence interval [CI]: 2.6 to 335.0; p < 0.01), the TAV–sinus of Valsalva relation (OR: 1.1 per 1-mm increase; 95% CI: 1.0 to 1.2; p < 0.01), and the mean TAV implantation depth (OR: 1.7 per 1-mm decrease; 95% CI: 1.3 to 2.3; p < 0.01) were found to be independent predictors of unsuccessful coronary cannulation after TAVR. A model combining these factors was demonstrated to predict with very high accuracy the risk for unsuccessful coronary cannulation after TAVR (area under the curve: 0.94; p < 0.01).ConclusionsUnsuccessful coronary cannulation following TAVR was observed in 7.7% of patients and occurred almost exclusively in those receiving Evolut TAVs. The combination of Evolut TAV, a higher TAV–sinus of Valsalva relation, and implantation depth predicts with high accuracy the risk for unsuccessful coronary cannulation after TAVR. (Reobtain Coronary Ostia Cannulation Beyond Transcatheter Aortic Valve Stent [RE-ACCESS]; NCT04026204)  相似文献   

10.
ObjectivesThe aim of this study was to assess the evolution of early outcomes for 3 iterative self-expanding transcatheter aortic valves.BackgroundOver the past decade there have been rapid advancements in transcatheter aortic valve replacement (TAVR) technologies, including 3 generations of supra-annular self-expanding transcatheter systems.MethodsData from the Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry for patients undergoing TAVR with CoreValve, Evolut R, or Evolut PRO valves to treat tricuspid aortic stenosis between January 2014 and September 2017 were obtained. Patient risk and echocardiographic data are site reported. Valves analyzed included 23-, 26-, and 29-mm sizes to fit 18- to 26-mm annular diameters. Propensity score matching was performed using the Evolut PRO group as the common reference.ResultsOf 18,874 patients undergoing TAVR at 381 centers, 5,514 patients were implanted with CoreValve, 11,295 with Evolut R, and 2,065 with Evolut PRO valves. At 30 days, there were significantly fewer patients with more than mild aortic regurgitation for the unmatched (7.8% CoreValve, 5.2% Evolut R, and 2.8% Evolut PRO; p < 0.001) and matched populations (8.3% CoreValve, 5.4% Evolut R, and 3.4% Evolut PRO; p = 0.032). The mean aortic valve gradients at 30 days in the matched populations were <8 mm Hg for all 3 valves (7.3 mm Hg CoreValve, 7.5 mm Hg Evolut R, 7.2 mm Hg Evolut PRO).ConclusionsAdvancements in transcatheter valve technologies and expanding indications for TAVR have resulted in improved outcomes for patients undergoing TAVR in the United States with self-expanding, supra-annular valves. In particular, the addition of an outer pericardial tissue wrap designed to enhance sealing at the level of the aortic annulus has resulted in very low rates of significant aortic regurgitation while maintaining excellent hemodynamic status.  相似文献   

11.
ObjectivesThis study aimed to evaluate the safety and mid-term efficacy of transcatheter aortic valve replacement (TAVR) in the setting of aortic valve (AV) infective endocarditis (IE) with residual lesion despite successful antibiotic treatment.BackgroundPatients with AV-IE presenting residual lesion despite successful antibiotic treatment are often rejected for cardiac surgery due to high-risk. The use of TAVR following IE is not recommended.MethodsThis was a multicenter retrospective study across 10 centers, gathering baseline, in-hospital, and 1-year follow-up characteristics of patients with healed AV-IE treated with TAVR. Matched comparison according to sex, EuroSCORE, chronic kidney disease, left ventricular function, prosthesis type, and valve-in-valve procedure was performed with a cohort of patients free of prior IE treated with TAVR (46 pairs).ResultsAmong 2,920 patients treated with TAVR, 54 (1.8%) presented with prior AV-IE with residual valvular lesion and healed infection. They had a higher rate of multivalvular disease and greater surgical risk scores. A previous valvular prosthesis was more frequent than a native valve (50% vs. 7.5%; p < 0.001). The in-hospital and 1-year mortality rates were 5.6% and 11.1%, respectively, comparable to the control cohort. After matching, the 1-year III to IV aortic regurgitation rate was 27.9% (vs. 10%; p = 0.08) and was independently associated with higher mortality. There was only 1 case of IE relapse (1.8%); however, 18% of patients were complicated with sepsis, and 43% were readmitted due to heart failure.ConclusionsTAVR is a safe therapeutic alternative for residual valvular lesion after successfully healed AV-IE. At 1-year follow-up, the risk of IE relapse was low and mortality rate did not differ from TAVR patients free of prior IE, but one-fourth presented with significant aortic regurgitation and >50% required re-admission.  相似文献   

12.
BackgroundTranscatheter aortic valve replacement (TAVR) use is increasing in patients with longer life expectancy, yet robust data on the durability of transcatheter heart valves (THVs) are limited. Redo-TAVR may play a key strategy in treating patients in whom THVs fail.ObjectivesThe authors sought to examine outcomes following redo-TAVR.MethodsThe Redo-TAVR registry collected data on consecutive patients who underwent redo-TAVR at 37 centers. Patients were classified as probable TAVR failure or probable THV failure if they presented within or beyond 1 year of their index TAVR, respectively.ResultsAmong 63,876 TAVR procedures, 212 consecutive redo-TAVR procedures were identified (0.33%): 74 within and 138 beyond 1 year of the initial procedure. For these 2 groups, TAVR-to-redo-TAVR time was 68 (38 to 154) days and 5 (3 to 6) years. The indication for redo-TAVR was THV stenosis in 12 (16.2%) and 51 (37.0%) (p = 0.002) and regurgitation or combined stenosis–regurgitation in 62 (83.8%) and 86 (62.3%) (p = 0.028), respectively. Device success using VARC-2 criteria was achieved in 180 patients (85.1%); most failures were attributable to high residual gradients (14.1%) or regurgitation (8.9%). At 30-day and 1-year follow-up, residual gradients were 12.6 ± 7.5 mm Hg and 12.9 ± 9.0 mm Hg; valve area 1.63 ± 0.61 cm2 and 1.51 ± 0.57 cm2; and regurgitation ≤mild in 91% and 91%, respectively. Peri-procedural complication rates were low (3 stroke [1.4%], 7 valve malposition [3.3%], 2 coronary obstruction [0.9%], 20 new permanent pacemaker [9.6%], no mortality), and symptomatic improvement was substantial. Survival at 30 days was 94.6% and 98.5% (p = 0.101) and 83.6% and 88.3% (p = 0.335) at 1 year for patients presenting with early and late valve dysfunction, respectively.ConclusionsRedo-TAVR is a relatively safe and effective option for selected patients with valve dysfunction after TAVR. These results are important for applicability of TAVR in patients with long life expectancy in whom THV durability may be a concern.  相似文献   

13.
ObjectivesThe aim of this study was to compare 5-year cardiovascular, renal, and bioprosthetic valve durability outcomes in patients with severe aortic stenosis (AS) and chronic kidney disease (CKD) undergoing transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR).BackgroundPatients with severe AS and CKD undergoing TAVR or SAVR are a challenging, understudied clinical subset.MethodsIntermediate-risk patients with moderate to severe CKD (estimated glomerular filtration rate <60 mL/min/m2) from the PARTNER (Placement of Aortic Transcatheter Valve) 2A trial (patients randomly assigned to SAPIEN XT TAVR or SAVR) and SAPIEN 3 Intermediate Risk Registry were pooled. The composite primary outcome of death, stroke, rehospitalization, and new hemodialysis was evaluated using Cox regression analysis. Patients with and without perioperative acute kidney injury (AKI) were followed through 5 years. A core laboratory–adjudicated analysis of structural valve deterioration and bioprosthetic valve failure was also performed.ResultsThe study population included 1,045 TAVR patients (512 SAPIEN XT, 533 SAPIEN 3) and 479 SAVR patients. At 5 years, SAVR was better than SAPIEN XT TAVR (52.8% vs 68.0%; P = 0.04) but similar to SAPIEN 3 TAVR (52.8% vs 58.7%; P = 0.89). Perioperative AKI was more common after SAVR than TAVR (26.3% vs 10.3%; P < 0.001) and was independently associated with long-term outcomes. Compared with SAVR, bioprosthetic valve failure and stage 2 or 3 structural valve deterioration were significantly greater for SAPIEN XT TAVR (P < 0.05) but not for SAPIEN 3 TAVR.ConclusionsIn intermediate-risk patients with AS and CKD, SAPIEN 3 TAVR and SAVR were associated with a similar risk for the primary endpoint at 5 years. AKI was more common after SAVR than TAVR, and SAPIEN 3 valve durability was comparable with that of surgical bioprostheses.  相似文献   

14.
ObjectivesThis study sought to compare outcomes in patients with bicuspid versus tricuspid anatomy undergoing transcatheter aortic valve replacement (TAVR).BackgroundTAVR has shown excellent safety and efficacy in patients with tricuspid aortic valve stenosis, but limited data are available on the use of self-expanding valves in patients with bicuspid valves.MethodsThe Society of Thoracic Surgeons/American College of Cardiology TVT Registry was used to analyze patients who underwent TAVR with the Evolut R or Evolut PRO valves. Clinical and echocardiographic outcomes were analyzed through 1-year follow-up.ResultsBetween July 2015 and September 2018 a total of 932 patients with bicuspid aortic valve stenosis underwent elective TAVR with the self-expanding Evolut R or Evolut PRO valve. These patients were compared with a group of 26,154 patients with tricuspid aortic stenosis who underwent TAVR during that same time period. At baseline, patients with bicuspid valves were younger, had fewer cardiac comorbidities, and had lower Society of Thoracic Surgeons Predicted Risk of Mortality scores (5.3 ± 4.2% vs. 6.9 ± 4.8%; p < 0.001). To account for these differences, propensity matching was performed, which resulted in 929 matched pairs. Within these match groups, the rates of all-cause mortality at 30 days (2.6% vs. 1.7%; p = 0.18) and 1 year (10.4% vs. 12.1%; p = 0.63), as well the rate of stroke at 30 days (3.4% vs. 2.7%; p = 0.41) and 1 year (3.9% vs. 4.4%; p = 0.93), were comparable.ConclusionsAll-cause mortality, stroke, and valve hemodynamics did not differ at 30 days or 1 year between patient groups. In patients at increased surgical risk, TAVR for bicuspid aortic valve stenosis indicates acceptable safety outcomes with low complications rates.  相似文献   

15.
BackgroundPatients with rheumatic aortic stenosis (AS) were excluded from transcatheter aortic valve replacement (TAVR) trials.ObjectivesThe authors sought to examine outcomes with TAVR versus surgical aortic valve replacement (SAVR) in patients with rheumatic AS, and versus TAVR in nonrheumatic AS.MethodsThe authors identified Medicare beneficiaries who underwent TAVR or SAVR from October 2015 to December 2017, and then identified patients with rheumatic AS using prior validated International Classification of Diseases, Version 10 codes. Overlap propensity score weighting analysis was used to adjust for measured confounders. The primary study outcome was all-cause mortality. Multiple secondary outcomes were also examined.ResultsThe final study cohort included 1,159 patients with rheumatic AS who underwent aortic valve replacement (SAVR, n = 554; TAVR, n = 605), and 88,554 patients with nonrheumatic AS who underwent TAVR. Patients in the SAVR group were younger and with lower prevalence of most comorbidities and frailty scores. After median follow-up of 19 months (interquartile range: 13 to 26 months), there was no difference in all-cause mortality with TAVR versus SAVR (11.2 vs. 7.0 per 100 person-year; adjusted hazard ratio: 1.53; 95% confidence interval: 0.84 to 2.79; p = 0.2). Compared with TAVR in nonrheumatic AS, TAVR for rheumatic AS was associated with similar mortality (15.2 vs. 17.7 deaths per 100 person-years (adjusted hazard ratio: 0.87; 95% confidence interval: 0.68 to 1.09; p = 0.2) after median follow-up of 17 months (interquartile range: 11 to 24 months). None of the rheumatic TAVR patients, <11 SAVR patients, and 242 nonrheumatic TAVR patients underwent repeat aortic valve replacement (124 redo-TAVR and 118 SAVR) at follow-up.ConclusionsCompared with SAVR, TAVR could represent a viable and possibly durable option for patients with rheumatic AS.  相似文献   

16.
ObjectivesThe aim of this study was to validate the 2019 consensus algorithm in a large cohort of contemporary transcatheter aortic valve replacement (TAVR) patients.BackgroundThe optimal management of patients with atrioventricular conduction disturbances after TAVR is unknown. Guidance was consolidated in an expert consensus algorithm in 2019.MethodsIn a retrospective analysis of a prospective registry, patients were classified according to the 2019 consensus algorithm as eligible for early discharge (day 1 or 2 after TAVR), higher risk for high-degree atrioventricular block (HAVB) or complete heart block (CHB) or in need for a permanent pacemaker (PPM). The primary endpoint was the incidence of PPM implantation for HAVB or CHB within 30 days after TAVR. Patients with prior PPM or implantable cardioverter-defibrillator implantation, valve-in-valve procedures, or incomplete electrocardiographic data were excluded.ResultsAmong 1,439 patients undergoing TAVR between January 2014 and December 2019, the 2019 consensus algorithm classified 73% as eligible for early discharge, 21% as at higher risk for HAVB or CHB, and 6% as in need of PPM. PPM implantation for HAVB or CHB occurred in 234 patients (16%) within 30 days after TAVR. The incidence of PPM implantation was 2.7% in the early discharge group, 41% in the group with higher risk for HAVB or CHB, and 100% in the PPM group.ConclusionsThe 2019 consensus algorithm safely identifies patients with no need for PPM implantation. This strategy allows more uniform management of TAVR patients and facilitates early discharge of low-risk patients without prolonged monitoring in 3 of 4 patients. However, the algorithm is less precise in the identification of high-risk patients.  相似文献   

17.
ObjectivesThe aim of this study was to report the outcomes of valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) at 5 years.BackgroundTAVR for degenerated surgical bioprostheses in patients at high risk for reoperative surgery is an important treatment option that may delay or obviate the need for surgical intervention; however, long-term outcomes of this procedure are unknown.MethodsThe PARTNER (Placement of Aortic Transcatheter Valves) 2 ViV and continued access registries prospectively enrolled patients with failed surgical bioprostheses at high risk for reoperation. Five-year clinical and echocardiographic follow-up data were obtained in 95.9% of patients.ResultsIn 365 (96 registry and 269 continued access) patients, the mean age was 78.9 ± 10.2 years, the mean Society of Thoracic Surgeons predicted risk of surgical mortality score was 9.1 ± 4.7%, and New York Heart Association functional class was III or IV in 90.4%. At 5 years, the Kaplan-Meier rates of all-cause mortality and any stroke were 50.6% and 10.5%, respectively. Using Valve Academic Research Consortium 3 definitions, the incidence of structural valve deterioration, related hemodynamic valve deterioration, or bioprosthetic valve failure at 5 years was 6.6%. Aortic valve re-replacement was performed in 6.3% (n = 14), the majority of which was due to stenosis (n = 6) and combined aortic insufficiency/paravalvular regurgitation (n = 3). The mean gradient, Doppler velocity index, paravalvular regurgitation, and quality of life measured by Kansas City Cardiomyopathy Questionnaire scores in survivors remained stable from 30 days postprocedure through 5 years.ConclusionsAt the 5-year follow-up, TAVR for bioprosthetic aortic valve failure in high surgical risk patients was associated with sustained improvement in clinical and echocardiographic outcomes.  相似文献   

18.
ObjectivesThe authors aimed to identify risk factors and outcomes associated with new-onset atrial fibrillation (NOAF) after transcatheter aortic valve replacement (TAVR).BackgroundNOAF is a common complication after TAVR, although estimates of the precise occurrence are variable. This study sought to quantify the occurrence of NOAF after TAVR and to explore the outcomes and predictors associated with this complication.MethodsWe searched Medline, EMBASE, and the Cochrane database from 2016 to 2020 for articles that reported NOAF after TAVR. We extracted data for studies published before 2016 from a previous systematic review. We pooled data using a random effects model.ResultsWe identified 179 studies with 241,712 total participants (55,271 participants with pre-existing atrial fibrillation (AF) were excluded) that reported NOAF from 2008 to 2020. The pooled occurrence of NOAF after TAVR was 9.9% (95% CI: 8.1%-12%). NOAF after TAVR was associated with a longer index hospitalization (mean difference = 2.66 days; 95% CI: 1.05-4.27), a higher risk of stroke in the first 30 days (risk ratio [RR]: 2.35; 95% CI: 2.12-2.61), 30-day mortality (RR: 1.76; 95% CI: 1.12-2.76), major or life-threatening bleeding (RR: 1.60; 95% CI: 1.39-1.84), and permanent pacemaker implantation (RR: 1.12; 95% CI: 1.05-1.18). Risk factors for the development of NOAF after TAVR included higher Society of Thoracic Surgeons score, transapical access, pulmonary hypertension, chronic kidney disease, peripheral vascular disease, and severe mitral regurgitation, suggesting that the risk for NOAF is highest in more comorbid TAVR patients.ConclusionsNOAF is common after TAVR. Whether AF after TAVR is a causal factor or a marker of sicker patients remains unclear.  相似文献   

19.
BackgroundTranscatheter aortic valve replacement (TAVR) is generally performed without control over the alignment of the bioprosthesis to the native aortic valve (AV) commissures. Data on the impact of commissural misalignment (CMA) on the clinical and hemodynamic outcome after TAVR are scarce.ObjectivesThe aim of this study was to investigate the impact of commissural misalignment (CMA) on the clinical and hemodynamic outcome in patients with severe tricuspid aortic stenosis undergoing TAVR using the balloon-expandable (BE) SAPIEN 3 valve (Edwards LifeSciences).MethodsClinical data of consecutive patients who underwent BE TAVR at Cedars-Sinai Medical Center (Los Angeles, California, USA) enrolled in the RESOLVE (Assessment of TRanscathetER and Surgical Aortic BiOprosthetic Valve Thrombosis and Its TrEatment With Anticoagulation) registry were retrospectively analyzed to evaluate CMA, which was defined as a neocommissure position >30° compared with native commissures on computed tomography.ResultsA total of 324 patients (36.6% female, median Society of Thoracic Surgeons score of 3.9%) were included in the analysis. CMA was present in 171 individuals (52.8%). At 30 days, rates of aortic regurgitation greater than mild (5.6%) and a residual AV gradient ≥20 mm Hg (7.4%) were not different between CMA and non-CMA patients. Commissural orientation was independently associated with a relative AV mean gradient increase >50% from discharge to 30 days (per increase of 10° misalignment; OR: 1.3; 95% CI: 1.0-1.4; P = 0.01). The long-term composite outcome of death or stroke was not different between groups (log-rank P = 0.29).ConclusionsIn patients with severe tricuspid aortic stenosis who undergo SAPIEN 3 TAVR, the neocommissures align randomly. Our data demonstrate that commissural alignment may impact device performance and clinical outcomes in patients undergoing BE TAVR. (Assessment of TRanscathetEr and Surgical Aortic BiOprosthetic VaLVve Dysfunction with Multimodality Imaging and Its TrEatment with Anticoagulation [RESOLVE]; NCT02318342)  相似文献   

20.
ObjectivesThe aim of this study was to investigate the online assessment feasibility of aortography using videodensitometry in the catheterization laboratory during transcatheter aortic valve replacement (TAVR).BackgroundQuantitative assessment of regurgitation after TAVR through aortography using videodensitometry is simple, reproducible, and validated in vitro, in vivo, in clinical trials, and in “real-world” patients. However, thus far the assessment has been done offline.MethodsThis was a single center, prospective, proof-of-principle, feasibility study. One hundred consecutive patients with aortic stenosis and indications to undergo TAVR were enrolled. All final aortograms were analyzed immediately after acquisition in the catheterization laboratory and were also sent to an independent core laboratory for blinded offline assessment. The primary endpoint of the study was the feasibility of the online assessment of regurgitation (percentage of analyzable cases). The secondary endpoint was the reproducibility of results between the online assessment and the offline analysis by the core laboratory.ResultsPatients’ mean age was 81 ± 7 years, and 56% were men. The implanted valves were either SAPIEN 3 (97%) or SAPIEN 3 Ultra (3%). The primary endpoint of online feasibility of analysis was 92% (95% confidence interval [CI]: 86% to 97%) which was the same feasibility encountered by the core laboratory (92%; 95% CI: 86% to 97%). Reproducibility assessment showed a high correlation between online and core laboratory evaluations (R2 = 0.87, p < 0.001), with an intraclass correlation coefficient of 0.962 (95% CI: 0.942 to 0.975; p < 0.001).ConclusionsThis study showed high feasibility of online quantitative assessment of regurgitation and high agreement between the online examiner and core laboratory. These results may pave the way for the application of videodensitometry in the catheterization laboratory after TAVR. (Online Videodensitometric Assessment of Aortic Regurgitation in the Cath-Lab [OVAL]; NCT04047082)  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号