首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
ObjectivesThe aim of this study was to assess the clinical outcome of baseline massive or torrential tricuspid regurgitation (TR) after transcatheter tricuspid valve intervention (TTVI).BackgroundThe use of TTVI to treat symptomatic severe TR has been increasing rapidly, but little is known regarding the impact of massive or torrential TR beyond severe TR.MethodsThe study population comprised 333 patients with significant symptomatic TR from the TriValve Registry who underwent TTVI. Mid-term outcomes after TTVI were assessed according to the presence of massive or torrential TR, defined as vena contracta width ≥14 mm. Procedural success was defined as patient survival after successful device implantation and delivery system retrieval, with residual TR ≤2+. The primary endpoint comprised survival rate and freedom from rehospitalization for heart failure, survival rate, and rehospitalization at 1 year.ResultsBaseline massive or torrential TR and severe TR were observed in 154 patients (46.2%) and 179 patients (53.8%), respectively. Patients with massive or torrential TR had a higher prevalence of ascites than those with severe TR (27.3% vs. 20.4%, respectively; p = 0.15) and demonstrated a similar procedural success rate (83.2% vs. 77.3%, respectively; p = 0.21). The incidence of peri-procedural adverse events was low, with no significant between-group differences. Freedom from the composite endpoint was significantly lower in patients with massive or torrential TR than in those with severe TR, which was significantly associated with an increased risk for 1-year death of any cause or rehospitalization for heart failure (adjusted hazard ratio: 1.91; 95% confidence interval: 1.10 to 3.34; p = 0.022). Freedom from the composite endpoint was significantly higher in patients with massive or torrential TR when procedural success was achieved (69.9% vs. 54.2%, p = 0.048).ConclusionsBaseline massive or torrential TR is associated with an increased risk for all-cause mortality and rehospitalization for heart failure 1 year after TTVI. Procedural success is related to better outcomes, even in the presence of baseline massive or torrential TR. (International Multisite Transcatheter Tricuspid Valve Therapies Registry [TriValve]; NCT03416166)  相似文献   

2.
ObjectivesThe aim of this registry was to evaluate the feasibility and safety of transcatheter tricuspid valve implantation (TTVI) in patients with extreme surgical risk.BackgroundIsolated tricuspid regurgitation (TR) surgery is associated with high in-hospital mortality.MethodsThirty consecutive patients (mean age 75 ± 10 years; 56% women) from 10 institutions, with symptomatic functional TR, had institutional and notified body approval for compassionate use of the GATE TTVI system. Baseline, discharge, and 30-day follow-up echocardiographic data and procedural, in-hospital, and follow-up clinical outcomes were collected.ResultsAt baseline, all patients had multiple comorbidities, severe or greater TR, and reduced baseline right ventricular function. Technical success was achieved in 26 of 30 patients (87%). Device malpositioning occurred in 4 patients, with conversion to open heart surgery in 2 (5%). Of those who received the device, 100% had reductions in TR of ≥1, and 75% experienced reductions of ≥2 grades, resulting in 18 of 24 of patients (76%) with mild or less TR at discharge. All patients had mild or less central TR. There was continued improvement in TR grade between discharge and 30 days in 15 of 19 patients (79%). In-hospital mortality was 10%. At mean follow-up of 127 ± 82 days, 4 patients (13%) had died. Of patients alive at follow-up, 62% were in New York Heart Association functional class I or II, with no late device-related adverse events.ConclusionsCompassionate treatment of severe, symptomatic functional TR using a first-generation TTVI device is associated with significant reduction in TR and improvement in functional status with acceptable in-hospital mortality. Further studies are needed to determine the appropriate patient population and long-term outcomes with TTVI therapy.  相似文献   

3.
ObjectivesThis study aimed to improve echocardiographic assessment of pulmonary hypertension (PH) in patients presenting with severe tricuspid regurgitation (TR).BackgroundEchocardiographic assessment of PH in patients with severe TR carries several pitfalls for underestimation, hence concealing the true severity of PH in very sick patients in particular, and ultimately obscuring the impact of PH on survival after transcatheter tricuspid valve intervention (TTVI).MethodsAll patients in this study underwent TTVI for severe TR between 2016 and 2020. To predict the mean pulmonary artery pressure (mPAP) solely based on echocardiographic parameters, we trained an extreme gradient boosting (XGB) algorithm. The derivation cohort was constituted by 116 out of 162 patients with both echocardiography and right heart catheterization data, preprocedurally obtained, from a bicentric registry. Moreover, 142 patients from an independent institution served for external validation.ResultsSystolic pulmonary artery pressure was consistently underestimated by echocardiography in comparison to right heart catheterization (40.3 ± 15.9 mm Hg vs 44.1 ± 12.9 mm Hg; P = 0.0066), and the assessment was most discrepant among patients with severe defects of the tricuspid valve and impaired right ventricular systolic function. Using 9 echocardiographic parameters as input variables, an XGB algorithm could reliably predict mPAP levels (R = 0.96, P < 2.2 × 10-16). Moreover, patients with elevations in predicted mPAP levels ≥29.9 mm Hg showed significantly reduced 2-year survival after TTVI (58.3% [95% CI: 41.7%-81.6%] vs 78.8% [95% CI: 68.7%-90.5%]; P = 0.026). Importantly, the poor prognosis associated with elevation in predicted mPAP levels was externally confirmed (HR for 2-year mortality: 2.9 [95% CI: 1.5-5.7]; P = 0.002).ConclusionsPH in patients with severe TR can be reliably assessed based on echocardiographic parameters in conjunction with an XGB algorithm, and elevations in predicted mPAP levels translate into increased mortality after TTVI.  相似文献   

4.
BackgroundWhether to repair nonsevere tricuspid regurgitation (TR) during surgery for ischemic mitral valve regurgitation (IMR) remains uncertain.ObjectivesThe goal of this study was to investigate the incidence, predictors, and clinical significance of TR progression and presence of ≥moderate TR after IMR surgery.MethodsPatients (n = 492) with untreated nonsevere TR within 2 prospectively randomized IMR trials were included. Key outcomes were TR progression (either progression by ≥2 grades, surgery for TR, or severe TR at 2 years) and presence of ≥moderate TR at 2 years.ResultsPatients’ mean age was 66 ± 10 years (67% male), and TR distribution was 60% ≤trace, 31% mild, and 9% moderate. Among 2-year survivors, TR progression occurred in 20 (6%) of 325 patients. Baseline tricuspid annular diameter (TAD) was not predictive of TR progression. At 2 years, 37 (11%) of 323 patients had ≥moderate TR. Baseline TR grade, indexed TAD, and surgical ablation for atrial fibrillation were independent predictors of ≥moderate TR. However, TAD alone had poor discrimination (area under the curve, ≤0.65). Presence of ≥moderate TR at 2 years was higher in patients with MR recurrence (20% vs. 9%; p = 0.02) and a permanent pacemaker/defibrillator (19% vs. 9%; p = 0.01). Clinical event rates (composite of ≥1 New York Heart Association functional class increase, heart failure hospitalization, mitral valve surgery, and stroke) were higher in patients with TR progression (55% vs. 23%; p = 0.003) and ≥moderate TR at 2 years (38% vs. 22%; p = 0.04).ConclusionsAfter IMR surgery, progression of unrepaired nonsevere TR is uncommon. Baseline TAD is not predictive of TR progression and is poorly discriminative of ≥moderate TR at 2 years. TR progression and presence of ≥moderate TR are associated with clinical events. (Comparing the Effectiveness of a Mitral Valve Repair Procedure in Combination With Coronary Artery Bypass Grafting [CABG] Versus CABG Alone in People With Moderate Ischemic Mitral Regurgitation, NCT00806988; Comparing the Effectiveness of Repairing Versus Replacing the Heart’s Mitral Valve in People With Severe Chronic Ischemic Mitral Regurgitation, NCT00807040)  相似文献   

5.
ObjectivesThe aim of this study was to investigate the incidence, characteristics, hemodynamic conditions, and clinical significance of right-to-left (R-L) shunt through an iatrogenic atrial septal defect (iASD) after the MitraClip procedure.BackgroundR-L shunt through an iASD after the MitraClip procedure has not been well investigated.MethodsFrom 2014 to 2017, 385 consecutive patients with mitral regurgitation underwent the MitraClip procedure. iASD was assessed using intraprocedural transesophageal echocardiography. Right and left heart catheterization was used to assess the hemodynamic status of patients. All patients provided written informed consent for the procedure. All data for this study were collected from an established interventional cardiology laboratory database approved by the Cedars-Sinai Medical Center Institutional Review Board.ResultsR-L shunt was observed in 20 patients (5%). In 7 of these patients (35%), R-L shunt was accompanied by acute deoxygenation. Prevalence of severe tricuspid regurgitation (55% vs. 20%; p = 0.001), serum B-type natriuretic peptide (664 pg/ml [434 to 1,169 pg/ml] vs. 400 pg/ml [195 to 699 pg/ml]; p = 0.006), mean pulmonary artery pressure (38 mm Hg [34 to 45 mm Hg] vs. 29 mm Hg [22 to 37 mm Hg]; p < 0.001), and right atrial pressure (19 mm Hg [13 to 20 mm Hg] vs. 10 mm Hg [7 to 14 mm Hg]; p < 0.001) were significantly higher in patients with R-L shunt than in those with left-to-right shunt. Patients with R-L shunt also showed a more prominent reduction in the left atrial V-wave and mean pressure from baseline to post-procedure compared with those with left-to-right shunt (−22.8 ± 2.6 mm Hg vs. −11.8 ± 0.9 mm Hg [p = 0.002] and −7.9 ± 0.8 mm Hg vs. −4.0 ± 0.4 mm Hg [p = 0.003], respectively).ConclusionsR-L shunt through an iASD was observed in 5% of patients who underwent the MitraClip procedure and in one-third of patients with R-L shunt presented acute deoxygenation. Elevated right atrial pressure concomitant with pulmonary hypertension and significant reduction in left atrial pressure after MitraClip deployment were associated with R-L shunt.  相似文献   

6.
ObjectivesThe aim of this study was to assess 30-day outcomes of transcatheter edge-to-edge repair with the MitraClip XTR for significant tricuspid regurgitation (TR), relative to baseline coaptation gap sizes (CGS).BackgroundTranscatheter edge-to-edge repair using the MitraClip NT for patients with significant TR is safe and efficacious; the utility of the MitraClip XTR is unknown.MethodsPatients with significant, symptomatic TR treated at a single site between April 2018 and December 2019, with consent and with complete data, were included (n = 50). Baseline and 30-day echocardiograms were assessed by an echocardiography core laboratory. Patients were divided into 3 subgroups on the basis of site-assessed CGS: subgroup I (< 7 mm), subgroup II (7 to 10 mm), and subgroup III (>10 mm).ResultsTechnical success of the MitraClip XTR implantation was 100% (88% in the septal-anterior position) using a median of 2 clips (interquartile range: 1 to 2). At 30 days, single-leaflet detachment was noted in 3 patients (6%), with no instances of device embolization. TR was reduced by 1 grade in subgroup I and by 2 grades in subgroups II and III. New York Heart Association functional class was reduced by 1 class in all 3 subgroups. The 6-min walk distance increased in subgroup I (+115 m; p = 0.014) and subgroup II (+31.5 m; p = 0.028) but not subgroup III (+50 m; p = 0.999). A CGS of ≤8.4 mm was predictive of a reduction to moderate or less TR.ConclusionsMitraClip XTR implantation is a safe, effective treatment for a wider range of CGS in patients with symptomatic, significant TR than prior device iterations. All patients showed improvement in New York Heart Association functional class, and those with CGS <10 mm also experienced improved functional capacity.  相似文献   

7.
BackgroundTricuspid regurgitation (TR) is a frequent disease with a progressive increase in mortality as disease severity increases. Transcatheter therapies for treatment of TR may offer a safe and effective alternative to surgery in this high-risk population.ObjectivesThe purpose of this report was to study the 1-year outcomes with the TriClip transcatheter tricuspid valve repair system, including repair durability, clinical benefit and safety.MethodsThe TRILUMINATE trial (n = 85) is an international, prospective, single arm, multicenter study investigating safety and performance of the TriClip Tricuspid Valve Repair System in patients with moderate or greater TR. Echocardiographic assessment was performed by a core laboratory.ResultsAt 1 year, TR was reduced to moderate or less in 71% of subjects compared with 8% at baseline (p < 0.0001). Patients experienced significant clinical improvements in New York Heart Association (NYHA) functional class I/II (31% to 83%, p < 0.0001), 6-minute walk test (272.3 ± 15.6 to 303.2 ± 15.6 meters, p = 0.0023) and Kansas City Cardiomyopathy Questionnaire (KCCQ) score (improvement of 20 ± 2.61 points, p < 0.0001). Significant reverse right ventricular remodeling was observed in terms of size and function. The overall major adverse event rate and all-cause mortality were both 7.1% at 1 year.ConclusionTranscatheter tricuspid valve repair using the TriClip device was found to be safe and effective in patients with moderate or greater TR. The repair itself was durable at reducing TR at 1 year and was associated with a sustained and marked clinical benefit with low mortality after 1 year in a fragile population that was at high surgical risk. (TRILUMINATE Study With Abbott Transcatheter Clip Repair System in Patients With Moderate or Greater TR; NCT03227757)  相似文献   

8.
ObjectivesThe purpose of this study was to determine whether the mitral valve (MV) total leaflet area (TLA)-to-mitral annular area (MAA) (TLA/MAA) ratio measured using 3-dimensional (3D) transesophageal echocardiography (TEE) was associated with residual mitral regurgitation (MR) after MitraClip implantation in patients with secondary MR.BackgroundThe factors influencing the results of MitraClip implantation for secondary MR are controversial. This study hypothesized that insufficient remodeling of the mitral leaflets relative to the annular dilation may be associated with significant MR after MitraClip implantation.MethodsThis study included patients with secondary MR treated with MitraClips. Using 3D TEE dataset, the TLA in diastole and MAA in systole were measured with dedicated software.ResultsIn a total cohort of 119 patients (mean age 74 ± 9 years; 61% male), significant residual MR (≥2+) was present in 43 patients (36%). In patients with significant residual MR, MAA was greater than in patients without residual MR (10.7 ± 2.4 cm2 vs. 9.0 ± 2.1 cm2; p < 0.001) whereas no significant difference was observed in TLA (12.2 ± 2.6 cm2 vs. 12.0 ± 2.9 cm2; p = 0.836). TLA/MAA ratio was lower in patients with significant residual MR as compared to their counterparts (1.14 ± 0.15 vs. 1.34 ± 0.16; p < 0.001), suggesting insufficient leaflet remodeling relative to annular dilation. On receiver-operating characteristic curve analysis, the TLA/MAA ratio had better discriminative power to identify patients who will have significant residual MR compared to MAA alone (area under the curve [AUC]: 0.830 vs. 0.723; p = 0.049).ConclusionsIn patients with secondary MR, insufficient mitral leaflet remodeling relative to the annulus dilation, as reflected by a lower TLA/MAA ratio, is associated with significant residual MR after MitraClip implantation.  相似文献   

9.
ObjectivesThe aim of this study was to retrospectively compare the characteristics, procedural courses, and outcomes of patients presenting with concomitant mitral regurgitation (MR) and tricuspid regurgitation (TR) in the TriValve (Transcatheter Tricuspid Valve Therapies) and TRAMI (Transcatheter Mitral Valve Interventions) registries.BackgroundTranscatheter mitral edge-to-edge valve repair (TMVR) has been shown to be successful in patients with severe MR. Lately, edge-to-edge repair has also emerged as a possible treatment for severe TR in patients at high risk for cardiac surgery. In patients with both severe MR and TR, the yield of concomitant transcatheter mitral and tricuspid valve repair (TMTVR) for patients at high surgical risk is unknown.MethodsThe characteristics, procedural data, and 1-year outcomes of all patients in the international multicenter TriValve registry and the German multicenter TRAMI registry, who presented with both severe MR and TR, were retrospectively compared. Patients in TRAMI (n = 106) underwent isolated TMVR, while those in TriValve (n = 122) additionally underwent concurrent TMTVR in compassionate and/or off-label use.ResultsAll 228 patients (mean age 77 ± 8 years, 44.3% women) presented with significant dyspnea at baseline (New York Heart Association functional class III or IV in 93.9%), without any differences in the rates of pulmonary hypertension and chronic pulmonary disease. The proportion of patients with left ventricular ejection fraction <30% was higher in the TMVR group (34.9% vs. 18.0%; p < 0.001), while patients in the TMTVR group had lower glomerular filtration rates. At discharge, MR was comparably reduced in both groups. At 1 year, overall all-cause mortality was 34.0% in the TMVR group and 16.4% in the TMTVR group (p = 0.035, Cox regression). On multivariate analysis, TMTVR was associated with a 2-fold lower mortality rate (hazard ratio: 0.52; p = 0.02). The rate of patients in New York Heart Association functional class ≤II at 1 year did not differ (69.4% vs. 67.0%; p = 0.54).ConclusionsConcurrent TMTVR was associated with a higher 1-year survival rate compared with isolated TMVR in patients with both MR and TR. Further randomized trials are needed to confirm these results.  相似文献   

10.
ObjectivesThe aim of this study was to assess the feasibility, efficacy, and clinical outcomes of transcatheter repair of tricuspid regurgitation (TR) in a pooled analysis of interventional studies.BackgroundNew percutaneous devices are available to treat severe TR, but the evidence is sparse and limited to smaller cohorts.MethodsSeveral electronic databases were searched for interventional studies involving percutaneous repair of TR. Devices used were the Cardioband, FORMA, MitraClip, PASCAL, and Trialign. Outcomes included in the final analysis were successful implantation, residual severe TR, post-procedural New York Heart Association (NYHA) functional class III or IV, 6-min walk distance, and echocardiographic parameters. Subgroup and meta-regression analysis were performed to further explore residual heterogeneity.ResultsSeven studies and 454 patients undergoing transcatheter tricuspid valve repair were included in the pooled analysis; 95% of patients had at least severe TR, and 91% were in NYHA functional class III or IV. Successful implantation was achieved in 86% of patients. At the longest follow-up available (weighted mean 265 days), 9% had died. Compared with baseline, a significantly lower proportion of patients had at least severe TR (relative risk: 0.38; 95% confidence interval: 0.20 to 0.70; p = 0.004) and were in NYHA functional class III or IV (relative risk: 0.23; 95% confidence interval: 0.20 to 0.30; p < 0.001). Patients also experienced increases in 6-min walk distance (mean difference +64.6 m; p < 0.001) and significant reductions in tricuspid valve annular diameter (mean difference −3 mm; p < 0.001), while left and right ventricular function did not change significantly.ConclusionsA strategy of transcatheter repair for severe TR appears to be feasible, effective, and associated with improved clinical outcomes at mid-term follow-up.  相似文献   

11.
ObjectivesThe authors sought to evaluate the association between mean mitral valve gradient (MVG) and clinical outcomes among patients who underwent MitraClip treatment for secondary mitral regurgitation (SMR) in the COAPT (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients with Functional Mitral Regurgitation) trial.BackgroundIn the COAPT trial, patients with heart failure (HF) and severe SMR who remained symptomatic despite guideline-directed medical therapy had marked 2-year reductions in mortality and HF hospitalizations after treatment with MitraClip.MethodsMitraClip-treated patients were divided into quartiles (Q) based on discharge echocardiographic MVG (n = 250). Endpoints including all-cause mortality, HF hospitalization, and health status measures at 2 years were compared between quartiles.ResultsMean MVG after MitraClip was 2.1 ± 0.4 mm Hg, 3.0 ± 0.2 mm Hg, 4.2 ± 0.5 mm Hg, and 7.2 ± 2.0 mm Hg in Q1 (n = 63), Q2 (n = 61), Q3 (n = 62), and Q4 (n = 64), respectively. There was no difference across quartiles in the 2-year composite endpoint of all-cause mortality or HF hospitalization (43.2%, 49.2%, 40.6%, and 40.9%, respectively; p = 0.80), nor in improvements in New York Heart Association functional class, Kansas City Cardiomyopathy Questionnaire score, or 6-min walk time. Results were similar after adjustment for baseline clinical and echocardiographic characteristics, post-procedure MR grade, and number of clips (all-cause mortality or HF hospitalization Q4 [44.6%] vs. Q1 to Q3 [40.3%]; adjusted hazard ratio: 1.23, 95% confidence interval: 0.60 to 2.51; p = 0.57).ConclusionsAmong HF patients with severe SMR, higher MVGs on discharge did not adversely affect clinical outcomes following MitraClip. These findings suggest that in select patients with HF and SMR otherwise meeting the COAPT inclusion criteria, the benefits of MR reduction may outweigh the effects of mild-to-moderate mitral stenosis after MitraClip.  相似文献   

12.
ObjectivesThis study sought to compare outcomes in patients with bicuspid versus tricuspid anatomy undergoing transcatheter aortic valve replacement (TAVR).BackgroundTAVR has shown excellent safety and efficacy in patients with tricuspid aortic valve stenosis, but limited data are available on the use of self-expanding valves in patients with bicuspid valves.MethodsThe Society of Thoracic Surgeons/American College of Cardiology TVT Registry was used to analyze patients who underwent TAVR with the Evolut R or Evolut PRO valves. Clinical and echocardiographic outcomes were analyzed through 1-year follow-up.ResultsBetween July 2015 and September 2018 a total of 932 patients with bicuspid aortic valve stenosis underwent elective TAVR with the self-expanding Evolut R or Evolut PRO valve. These patients were compared with a group of 26,154 patients with tricuspid aortic stenosis who underwent TAVR during that same time period. At baseline, patients with bicuspid valves were younger, had fewer cardiac comorbidities, and had lower Society of Thoracic Surgeons Predicted Risk of Mortality scores (5.3 ± 4.2% vs. 6.9 ± 4.8%; p < 0.001). To account for these differences, propensity matching was performed, which resulted in 929 matched pairs. Within these match groups, the rates of all-cause mortality at 30 days (2.6% vs. 1.7%; p = 0.18) and 1 year (10.4% vs. 12.1%; p = 0.63), as well the rate of stroke at 30 days (3.4% vs. 2.7%; p = 0.41) and 1 year (3.9% vs. 4.4%; p = 0.93), were comparable.ConclusionsAll-cause mortality, stroke, and valve hemodynamics did not differ at 30 days or 1 year between patient groups. In patients at increased surgical risk, TAVR for bicuspid aortic valve stenosis indicates acceptable safety outcomes with low complications rates.  相似文献   

13.
ObjectivesThis study aimed to assess whether patients with MAD also have disjunction of the tricuspid annulus.BackgroundMitral annulus disjunction (MAD) is an abnormal atrial displacement of the mitral annulus. Whether the disjunction extends to the right side of the heart is not known.MethodsIn a cohort of patients with MAD, we assessed the presence of tricuspid annulus disjunction (TAD) with the use of cardiac magnetic resonance. We explored the associations between TAD and MAD characteristics and the relationship to ventricular arrhythmias (nonsustained/sustained ventricular tachycardias and aborted cardiac arrest).ResultsWe included 84 patients (mean age: 48 ± 16 years; 63% female). We observed TAD in 42 (50%). Patients with TAD were older (age 52 ± 16 years vs. 43 ± 15 years; p = 0.02), had greater circumferential extent of MAD (164 ± 57° vs. 115 ± 58°; p = 0.002), greater maximum longitudinal MAD distance (9.4 ± 2.9 mm vs. 6.2 ± 2.8 mm; p < 0.001), and more frequent mitral valve prolapse (n = 39 [92%] vs. n = 24 [57%]; p < 0.001). Ventricular arrhythmias had occurred in 34 patients (41%), who were younger (age 39 ± 14 years vs. 54 ± 14 years; p < 0.001) and had lower prevalence of TAD (n = 22 [29%] vs. n = 12 [52%]; p = 0.03). TAD was not associated with ventricular arrhythmias when adjusted for age (odds ratio adjusted for age: 0.54; 95% confidence interval: 0.20 to 1.45; p = 0.22).ConclusionsWe report for the first time the existence of right-sided annulus disjunction as a common finding in patients with MAD. TAD was associated with more severe left-sided annulus disjunction and mitral valve prolapse, but not with ventricular arrhythmias.  相似文献   

14.
ObjectivesThe aim of this study was to assess the pooled clinical and echocardiographic outcomes of different isolated transcatheter tricuspid valve repair (ITTVR) strategies for significant (moderate or greater) tricuspid regurgitation (TR).BackgroundSignificant TR is a common valvular heart disease worldwide.MethodsPublished research was systematically searched for studies evaluating the efficacy and safety of ITTVR for significant TR in adults. The primary outcomes were improvement in New York Heart Association (NYHA) functional class and 6-minute walking distance and the presence of severe or greater TR at the last available follow-up of each individual study. Random-effect meta-analysis was performed comparing outcomes before and after ITTVR.ResultsFourteen studies with 771 patients were included. The mean age was 77 ± 8 years, and the mean European System for Cardiac Operative Risk Evaluation II score was 6.8% ± 5.4%. At a weighted mean follow-up of 212 days, 209 patients (35%) were in NYHA functional class III or IV compared with 586 patients (84%) at baseline (risk ratio: 0.23; 95% CI: 0.13-0.40; P < 0.001). Six-minute walking distance significantly improved from 237 ± 113 m to 294 ± 105 m (mean difference +50 m; 95% CI: +34 to +66 m; P < 0.001). One hundred forty-seven patients (24%) showed severe or greater TR after ITTVR compared with 616 (96%) at baseline (risk ratio: 0.29; 95% CI: 0.20-0.42; P < 0.001).ConclusionsPatients undergoing ITTVR for significant TR experienced significant improvements in NYHA functional status and 6-minute walking distance and a significant reduction in TR severity at mid-term follow-up.  相似文献   

15.
ObjectivesThis study sought to report short-term results of safety, performance, and efficacy of the Mistral device first-in-human study in patients suffering from severe functional tricuspid insufficiency.BackgroundPatients who suffer from severe tricuspid regurgitation (TR) and who are at high surgical risk have no standard care therapy. Therefore, minimally invasive and safer methods are sought. The Mistral device is an investigational spiral-shaped device intended for percutaneous transcatheter repair. The Mistral device approximates the tricuspid leaflets by grasping together the chordae tendineae of the tricuspid valve.MethodsSeven patients (4 women; mean age 73.14 ± 7.4 years) with severe (n = 5) and massive (n = 2) symptomatic TR and high surgical risk underwent Mistral tricuspid repair under transesophageal echocardiography guidance.ResultsMistral was successfully implanted in all cases with a single device deployed in 6 patients, with 2 devices deployed in 1 patient. No procedural or 30-day adverse events occurred. TR was reduced by at least 1 grade in all patients. Effective regurgitant orifice area was reduced from median 0.52 cm2 (interquartile range [IQR]: 0.40 to 0.60 cm2) at baseline to 0.15 cm2 (IQR: 0.14 to 0.21 cm2) at 30 days post-procedure (p < 0.01), vena contracta width was reduced from 0.95 cm (IQR: 0.81 to 1.16 cm) to 0.62 cm (IQR: 0.52 to 0.67 cm) (p < 0.05), and regurgitant volume decreased from 49.4 ml/beat (IQR: 45.2 to 57.7 ml/beat) to 19.7 ml/beat (IQR: 12.4 to 23.9 ml/beat) (p < 0.01). Right ventricular fractional area change improved from 27.0% (IQR: 21.3% to 33.5%) at baseline to 38.5% (IQR: 29.0% to 47.1%) at 30-day follow-up (p < 0.05). Significant improvements in New York Heart Association functional class, Kansas City Cardiomyopathy Questionnaire score, and 6-min walk test were observed at 30 days.ConclusionsTricuspid valve repair with the Mistral device appears safe and leads to 30-day reduction of tricuspid insufficiency and improvement of right ventricular function and exercise capacity.  相似文献   

16.
ObjectivesThis study aimed to assess the anatomical leaflet variation and investigate its impact on the procedural outcome in patients undergoing transcatheter edge-to-edge tricuspid repair.BackgroundTricuspid regurgitation (TR) is associated with a poor prognosis.MethodsThe study participants were consecutive patients who underwent transcatheter edge-to-edge tricuspid repair with the MitraClip, TriClip, or PASCAL systems from June 2015 to July 2020 at the Bonn Heart Center. The tricuspid leaflet morphologies were imaged using 2-dimensional and 3-dimensional transesophageal echocardiography. The severity of TR was assessed according to the 5-grade scheme. The primary endpoint was residual TR ≥3+ within 30 days.ResultsOf the 145 study participants, 103 (71.1%) participants were categorized as the 3-leaflet configuration, while 42 (28.9%) were categorized as the 4-leaflet configuration. Successful device implantation was achieved in 136 (93.8%) patients, with no statistical difference between the 3-leaflet and 4-leaflet configuration groups. However, compared with patients with a 3-leaflet configuration, patients with 4-leaflet configuration more frequently had residual TR ≥3+ (18.4% vs 38.1%; P = 0.018). In the multivariable model, the 4-leaflet configuration was associated with an increased risk of residual TR ≥3+ (odds ratio: 2.65; 95% CI 1.15-6.10; P = 0.022), independent of baseline TR grade, coaptation gap width, and TR jet location. After 1-year follow-up, compared with patients with residual TR <3+, patients with residual TR ≥3+ had a significantly higher incidence of the composite of all-cause mortality or heart failure hospitalization (27.7% vs 56.1%; P = 0.016).ConclusionsA 4-leaflet configuration of the tricuspid valve is observed in approximately one-third of patients undergoing transcatheter edge-to-edge tricuspid repair, which is associated with an increased risk of residual TR after the procedure.  相似文献   

17.
BackgroundTranscatheter treatment techniques for tricuspid regurgitation (TR) have evolved in recent years, with leaflet repair being the most commonly used, but thus far evidence on the PASCAL and PASCAL Ace system is based mainly on compassionate use data.ObjectivesThis is the first report on commercial use in a multicenter study with a large patient cohort investigating the safety and efficacy of the PASCAL and PASCAL Ace system in the treatment of TR.MethodsIn a retrospective, multicenter, observational setting, data from all consecutive patients undergoing leaflet repair for TR at 8 centers was collected, including a centralized analysis of echocardiographic data.ResultsA total of 235 high-risk patients (mean age 78 ± 8 years, 49% women, mean Society of Thoracic Surgeons Predicted Risk of Mortality score 8.6% ± 6.8%) were included. TR was functional in 87% of patients and graded severe or higher in 91%. TR was successfully reduced to moderate or less in 78% of patients (P < 0.001). Procedural success was 78% (n = 153). At the latest available follow-up (median 173 days), TR reduction was sustained (78% with TR moderate or less; P < 0.001), and echocardiography showed indications of right ventricular remodeling (mean right ventricular end-diastolic diameter 56 ± 9 mm vs 53 ± 9 mm; P < 0.001). Patients’ symptoms diminished significantly (63% were in New York Heart Association functional class I or II at follow-up; P < 0.001). In a device-specific analysis, the PASCAL and PASCAL Ace showed no difference in TR reduction (postprocedural TR moderate or less in 77% vs 78%; P = 0.82).ConclusionsIn early clinical experience, the PASCAL (Ace) leaflet repair system has high technical and procedural success rates with efficient TR reduction and significant clinical and echocardiographic improvement at follow-up.  相似文献   

18.
BackgroundSurgical aortic valve replacement and transcatheter aortic valve replacement (TAVR) are now both used to treat aortic stenosis in patients in whom life expectancy may exceed valve durability. The choice of initial bioprosthesis should therefore consider the relative safety and efficacy of potential subsequent interventions.ObjectivesThe aim of this study was to compare TAVR in failed transcatheter aortic valves (TAVs) versus surgical aortic valves (SAVs).MethodsData were collected on 434 TAV-in-TAV and 624 TAV-in-SAV consecutive procedures performed at centers participating in the Redo-TAVR international registry. Propensity score matching was applied, and 330 matched (165:165) patients were analyzed. Principal endpoints were procedural success, procedural safety, and mortality at 30 days and 1 year.ResultsFor TAV-in-TAV versus TAV-in-SAV, procedural success was observed in 120 (72.7%) versus 103 (62.4%) patients (p = 0.045), driven by a numerically lower frequency of residual high valve gradient (p = 0.095), ectopic valve deployment (p = 0.081), coronary obstruction (p = 0.091), and conversion to open heart surgery (p = 0.082). Procedural safety was achieved in 116 (70.3%) versus 119 (72.1%) patients (p = 0.715). Mortality at 30 days was 5 (3%) after TAV-in-TAV and 7 (4.4%) after TAV-in-SAV (p = 0.570). At 1 year, mortality was 12 (11.9%) and 10 (10.2%), respectively (p = 0.633). Aortic valve area was larger (1.55 ± 0.5 cm2 vs. 1.37 ± 0.5 cm2; p = 0.040), and the mean residual gradient was lower (12.6 ± 5.2 mm Hg vs. 14.9 ± 5.2 mm Hg; p = 0.011) after TAV-in-TAV. The rate of moderate or greater residual aortic regurgitation was similar, but mild aortic regurgitation was more frequent after TAV-in-TAV (p = 0.003).ConclusionsIn propensity score–matched cohorts of TAV-in-TAV versus TAV-in-SAV patients, TAV-in-TAV was associated with higher procedural success and similar procedural safety or mortality.  相似文献   

19.
ObjectivesThe aim of this observational study was to evaluate the impact of concomitant coronary artery disease (CAD) on outcomes in patients undergoing percutaneous valve repair with the MitraClip system.BackgroundMitral valve regurgitation and CAD are often coexistent in elderly patients undergoing percutaneous mitral valve repair. The impact of CAD and revascularization on outcomes in this patient cohort, however, remains uncertain.MethodsIn 444 MitraClip patients, CAD severity was assessed, represented by the SYNTAX (Synergy Between Percutaneous Coronary Intervention With Taxus and Cardiac Surgery) score (SS), as well as the residual SS (rSS) and SYNTAX score II (SS-II). Patients were stratified according to CAD severity and SS-II values (SS ≤3 vs. SS >3 and SS-II ≤45 vs. SS-II >45) and according to remaining CAD burden into 2 groups (rSS = 0 vs. rSS >0) to compare 1-year all-cause mortality.ResultsHigher SS, rSS, and SS-II were associated with mortality (22% for SS >3 vs. 9.6% for SS ≤3 [p < 0.001], 31.4% for rSS >0 vs. 9.6% for rSS = 0 [p < 0.001], and 17.1% for SS-II > 45 vs. 11.2% for SS-II ≤45 [p = 0.044]). The rSS was an independent predictor of 1-year all-cause mortality (p = 0.001) in multivariate analysis.ConclusionsThe complexity of CAD, as assessed using the SS, is associated with outcomes in patients undergoing MitraClip procedures. The burden of residual CAD after percutaneous coronary intervention is an independent predictor of 1-year all-cause mortality. Patients undergoing complete revascularization had the most favorable outcomes independent of mitral regurgitation etiology.  相似文献   

20.
ObjectivesThe aim of this study was to investigate changes in quality of life (QoL) after transcatheter tricuspid valve repair (TTVR) for tricuspid regurgitation (TR).BackgroundTTVR provides feasible and durable efficacy in reducing TR, but its clinical benefits on QoL still remain unclear.MethodsIn 115 subjects undergoing TTVR for severe functional TR, QoL was evaluated using the 36-Item Short Form Health Survey (SF-36) and the Minnesota Living With Heart Failure Questionnaire (MLHFQ). All-cause mortality, heart failure (HF) rehospitalization, and a composite endpoint of all-cause mortality, HF rehospitalization, and repeat TTVR were recorded as clinical events.ResultsSuccessful device implantation was achieved in 110 patients (96%). Moderate or less TR at discharge was achieved in 95 patients (83%). Mean SF-36 physical component summary (PCS) score improved from 34 ± 9 to 37 ± 9 points (+3 points; 95% CI: 1-5 points; P = 0.001), mean SF-36 mental component summary score improved from 49 ± 9 to 51 ± 10 points (+2 points; 95% CI: 0-4 points; P = 0.017), and mean MLHFQ score decreased from 29 ± 14 to 20 ± 15 points (−8 points; 95% CI: −11 to −5 points; P < 0.001). Baseline PCS, moderate or less TR at discharge, and baseline massive or torrential TR were associated with 1-month change in PCS score (P < 0.05). Change in PCS score after 1 month predicted HF rehospitalization after TTVR (adjusted HR: 0.74 [95% CI: 0.60-0.92] per 5-point increase in PCS score; P = 0.008).ConclusionsThis study demonstrates that TTVR provides improvement in QoL in patients with relevant TR. TR reduction to a moderate or less grade was associated with improvement of SF-36 and MLHFQ scores. Further, global QoL was associated with clinical outcomes and might serve as a future outcome surrogate following TTVR.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号