首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
ObjectivesThe aim of this study was to assess the evolution of early outcomes for 3 iterative self-expanding transcatheter aortic valves.BackgroundOver the past decade there have been rapid advancements in transcatheter aortic valve replacement (TAVR) technologies, including 3 generations of supra-annular self-expanding transcatheter systems.MethodsData from the Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry for patients undergoing TAVR with CoreValve, Evolut R, or Evolut PRO valves to treat tricuspid aortic stenosis between January 2014 and September 2017 were obtained. Patient risk and echocardiographic data are site reported. Valves analyzed included 23-, 26-, and 29-mm sizes to fit 18- to 26-mm annular diameters. Propensity score matching was performed using the Evolut PRO group as the common reference.ResultsOf 18,874 patients undergoing TAVR at 381 centers, 5,514 patients were implanted with CoreValve, 11,295 with Evolut R, and 2,065 with Evolut PRO valves. At 30 days, there were significantly fewer patients with more than mild aortic regurgitation for the unmatched (7.8% CoreValve, 5.2% Evolut R, and 2.8% Evolut PRO; p < 0.001) and matched populations (8.3% CoreValve, 5.4% Evolut R, and 3.4% Evolut PRO; p = 0.032). The mean aortic valve gradients at 30 days in the matched populations were <8 mm Hg for all 3 valves (7.3 mm Hg CoreValve, 7.5 mm Hg Evolut R, 7.2 mm Hg Evolut PRO).ConclusionsAdvancements in transcatheter valve technologies and expanding indications for TAVR have resulted in improved outcomes for patients undergoing TAVR in the United States with self-expanding, supra-annular valves. In particular, the addition of an outer pericardial tissue wrap designed to enhance sealing at the level of the aortic annulus has resulted in very low rates of significant aortic regurgitation while maintaining excellent hemodynamic status.  相似文献   

2.
ObjectivesThe aim of this study was to assess the outcomes of severe prosthesis-patient mismatch (PPM) in the TVT (Transcatheter Valve Therapy) Registry in patients undergoing supra-annular transcatheter aortic valve replacement (TAVR) for de novo stenosis or failed surgical bioprostheses (transcatheter aortic valve [TAV]–in–surgical aortic valve [SAV]).BackgroundSevere PPM has been associated with adverse outcomes following TAVR, yet the clinical outcome of severe PPM after supra-annular TAVR is largely unknown.MethodsSupra-annular TAVR was performed in patients enrolled in the TVT Registry with de novo stenosis (n = 42,174) or TAV-in-SAV (n = 5,446). Valve Academic Research Consortium-3 criteria were used to define severe PPM. The clinical impact of severe PPM on 1-year mortality and valve-related readmission was assessed using multivariate regression. A generalized linear mixed model was used to evaluate predictors of severe PPM.ResultsSevere PPM was found in 5.3% of patients undergoing de novo TAVR and 27.0% of patients undergoing TAV-in-SAV. The presence of severe PPM was not significantly associated with 1-year mortality or valve-related readmissions in both groups. Mean aortic gradients were higher in patients with severe PPM than in those without severe PPM at 1 month (9.7 ± 5.7 mm Hg vs. 7.3 ± 4.0 mm Hg; p < 0.001) and 1 year (10.2 ± 6.4 mm Hg vs. 8.0 ± 4.3 mm Hg; p < 0.001). Pre-procedural factors, including a <20-mm aortic annulus, were positive predictors of severe PPM in patients undergoing de novo TAVR (area under the curve = 0.795) and TAV-in-SAV (area under the curve = 0.764).ConclusionsSevere PPM after supra-annular TAVR was not associated with increased 1-year mortality or valve-related readmissions. Longer-term follow-up is needed to determine if higher residual gradients in patients with severe PPM predict long-term outcomes. (STS/ACC Transcatheter Valve Therapy Registry [TVT Registry]; NCT01737528)  相似文献   

3.
ObjectivesThe aim of this study was to investigate age-related outcomes of patients undergoing transcatheter aortic valve replacement (TAVR) as assessed in a nationwide, prospective, multicenter cohort study.BackgroundTAVR is the preferred treatment for elderly patients with severe aortic stenosis and is expanding into lower age groups.MethodsData from the SwissTAVI Registry were analyzed. Clinical outcomes were compared between patients 70 years of age or younger (n = 324), 70 to 79 years of age (n = 1,913), 80 to 89 years of age (n = 4,353), and older than 90 years of age (n = 507). Observed deaths were correlated with expected deaths in the general Swiss population using standardized mortality ratios.ResultsBetween February 2011 and June 2018, 7,097 patients (mean age 82.0 ± 6.4 years, 49.6% women) underwent TAVR at 15 hospitals in Switzerland. Procedural characteristics were similar; however, older patients more often had discharge to the referring hospital or a rehabilitation facility after TAVR. Using adjusted analyses, a linear trend for mortality (30-day adjusted hazard ratio [HRadj]: 1.45; 95% confidence interval [CI]: 1.18 to 1.77; 1-year HRadj: 1.12; 95% CI: 1.01 to 1.24), cerebrovascular accidents (30-day HRadj: 1.35; 95% CI: 1.09 to 1.66; 1-year HRadj: 1.21; 95% CI: 1.02 to 1.45), and pacemaker implantation (30-day HRadj: 1.23; 95% CI: 1.12 to 1.34; 1-year HRadj: 1.19; 95% CI: 1.09 to 1.30) was observed with increasing age. Furthermore, standardized mortality ratios were 12.63 (95% CI: 9.06 to 17.58), 4.09 (95% CI: 3.56 to 4.74), 1.63 (95% CI: 1.50 to 1.78), and 0.93 (95% CI: 0.76 to 1.14) for TAVR patients in relation to the Swiss population <70, 70 to 79, 80 to 89 and ≥90 years of age, respectively.ConclusionsIncreasing age is associated with a linear trend for mortality, stroke, and pacemaker implantation during early and longer-term follow-up after TAVR. Standardized mortality ratios were higher for TAVR patients younger than 90 years of age compared with expected rates of mortality in an age- and sex-matched Swiss population. (SWISS TAVI Registry; NCT01368250)  相似文献   

4.
ObjectivesThe aim of this study was to compare the feasibility, safety, and clinical outcomes of transcatheter aortic valve replacement (TAVR) in bicuspid aortic valve (BAV) versus tricuspid aortic valve (TAV) stenosis.BackgroundAt present, limited observational data exist supporting TAVR in the context of bicuspid anatomy.MethodsPrimary endpoints were 1-year survival and device success. Secondary endpoints included moderate to severe paravalvular leak (PVL) and a composite endpoint of periprocedural complications; incidence rates of individual procedural endpoints were also explored individually.ResultsIn the main analysis, 17 studies and 181,433 patients undergoing TAVR were included, of whom 6,669 (0.27%) had BAV. A secondary analysis of 7,071 matched subjects with similar baseline characteristics was also performed. Device success and 1-year survival rates were similar between subjects with BAV and those with TAV (97% vs 94% [P = 0.55] and 91.3% vs 90.8% [P = 0.22], respectively). In patients with BAV, a trend toward a higher risk for periprocedural complications was observed in our main analysis (risk ratio [RR]: 1.12; 95% CI: 0.99-1.27; P = 0.07) but not in the matched population secondary analysis (RR: 1.00; 95% CI: 0.81-1.24; P = 0.99). The risk for moderate to severe PVL was higher in subjects with BAV (RR: 1.42; 95% CI: 1.29-1.58; P < 0.0001) as well as the incidence of cerebral ischemic events (2.4% vs 1.6%; P = 0.015) and of annular rupture (0.3% vs 0.02%; P = 0.014) in matched subjects.ConclusionsTAVR is a feasible option among selected patients with BAV anatomy, but the higher rates of moderate to severe PVL, annular rupture, and cerebral ischemic events observed in the BAV group warrant caution and further evidence.  相似文献   

5.
ObjectivesThis study sought to better understand out-of-hospital 30-day mortality following transfemoral transcatheter aortic valve replacement (TAVR) and identify factors associated with poor outcomes.BackgroundDespite improvements in outcomes with TAVR for severe aortic stenosis, out-of-hospital 30-day mortality has not been evaluated.MethodsThis study examined patients in the Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry undergoing TAVR for severe aortic stenosis from January 2015 to March 2018. Primary and secondary endpoints were 30-day out-of-hospital all-cause mortality and out-of-hospital cardiovascular mortality, respectively. Logistic regression models were used to assess association between pre-specified factors and endpoints.ResultsA total of 106,749 patients underwent TAVR and were eligible for analysis. Transfemoral TAVR was performed in 92.3% of patients. A total of 2,137 (2.2%) transfemoral patients died within 30 days of the procedure, and 623 (29%) patients of these patients experienced out-of-hospital 30-day mortality. Cardiovascular and pulmonary etiologies accounted for the majority of observed mortality. Multivariable regression analysis identified older age, gender, lower body surface area, lower left ventricular ejection fraction, lower hemoglobin, atrial fibrillation or flutter, severe lung disease, home oxygen use, lack of moderate-to-severe aortic insufficiency, urgent TAVR, lower Kansas City Cardiomyopathy Questionnaire score, longer hospital length of stay, and in-hospital complications as being independently associated with the primary endpoint. New onset or pre-existent atrial fibrillation or flutter was also independently associated with 30-day out-of-hospital cardiovascular mortality in the transfemoral population.ConclusionsWe identified 30-day all-cause mortality rate for TAVR of 2.2%. Approximately one-third of patients experienced out-of-hospital mortality at 30 days. Several factors were identified as being independently associated with 30-day out-of-hospital all-cause and cardiovascular mortality. Further work is needed to understand how best to improve out-of-hospital mortality following TAVR.  相似文献   

6.
ObjectivesThe study compared 1-year outcomes between transcatheter aortic valve replacement (TAVR) patients with bicuspid aortic valve (BAV) morphology and clinically similar patients having tricuspid aortic valve (TAV) morphology.BackgroundThere are limited prospective data on TAVR using the SAPIEN 3 device in low-surgical-risk patients with severe, symptomatic aortic stenosis and bicuspid anatomy.MethodsLow-risk, severe aortic stenosis patients with BAV were candidates for the PARTNER 3 (Placement of Aortic Transcatheter Valves 3) (P3) bicuspid registry or the P3 bicuspid continued access protocol. Patients treated in these registries were pooled and propensity score matched to TAV patients from the P3 randomized TAVR trial. Outcomes were compared between groups. The primary endpoint was the 1-year composite rate of death, stroke, and cardiovascular rehospitalization.ResultsOf 320 total submitted BAV patients, 169 (53%) were treated, and most were Sievers type 1. The remaining 151 patients were excluded caused by anatomic or clinical criteria. Propensity score matching with the P3 TAVR cohort (496 patients) yielded 148 pairs. There were no differences in baseline clinical characteristics; however, BAV patients had larger annuli and they experienced longer procedure duration. There was no difference in the primary endpoint between BAV and TAV (10.9% vs 10.2%; P = 0.80) or in the rates of the individual components (death: 0.7% vs 1.4%; P = 0.58; stroke: 2.1% vs 2.0%; P = 0.99; cardiovascular rehospitalization: 9.6% vs 9.5%; P = 0.96).ConclusionsAmong highly select bicuspid aortic stenosis low-surgical-risk patients without extensive raphe or subannular calcification, TAVR with the SAPIEN 3 valve demonstrated similar outcomes to a matched cohort of patients with tricuspid aortic stenosis.  相似文献   

7.
ObjectivesThe aim of this study was to compare 1-year outcomes after transcatheter aortic valve replacement (TAVR) in low surgical risk patients with bicuspid aortic stenosis to patients with tricuspid aortic stenosis.BackgroundThe pivotal TAVR trials excluded patients with bicuspid aortic valves. The Low Risk Bicuspid Study 30-day primary endpoint of death or disabling stroke was 1.3%.MethodsThe Low Risk Bicuspid Study is a prospective, single-arm, TAVR trial that enrolled patients from 25 U.S. sites. A screening committee confirmed bicuspid anatomy and valve classification on computed tomography using the Sievers classification. Valve sizing was by annular measurements. An independent clinical events committee adjudicated all serious adverse events, and an independent core laboratory assessed all echocardiograms. The 150 patients from the Low Risk Bicuspid Study were propensity matched to the TAVR patients in the randomized Evolut Low Risk Trial using the 1:1 5- to-1-digit greedy method, resulting in 145 pairs.ResultsAll-cause mortality or disabling stroke at 1 year was 1.4% in the bicuspid and 2.8% in the tricuspid group (P = 0.413). A pacemaker was implanted in 16.6% of bicuspid and 17.9% of tricuspid patients (P = 0.741). The effective orifice area was similar between groups at 1 year (2.2 ± 0.7 cm2 vs 2.3 ± 0.6 cm2, P = 0.677) as was the mean gradient (8.7 ± 3.9 mm Hg vs 8.5 ± 3.1 mm Hg, P = 0.754). Fewer patients in the bicuspid group had mild or worse paravalvular leak (21.3% vs 42.6%, P < 0.001).ConclusionsThere were no significant differences in clinical or forward flow hemodynamic outcomes between the propensity-matched groups at 1 year.  相似文献   

8.
ObjectivesThis study sought to compare patient characteristics, procedural outcomes, and valve hemodynamics of surgical aortic valve replacement (SAVR) with current-generation rapid-deployment valves (RDVs) versus transcatheter aortic valve replacement (TAVR) with current-generation transcatheter heart valves (THVs).BackgroundThe patient population currently treated with RDVs may have potential similarities with the current TAVR population, but comparative studies in a large patient population remain scarce.MethodsA total of 16,473 patients who underwent isolated SAVR using current-generation RDVs or isolated transfemoral TAVR with current-generation THVs between 2011 and 2017 were enrolled into the German Aortic Valve Registry. Baseline, procedural, and in-hospital outcome parameters were analyzed for RDVs and THVs before and after 1:1 propensity score matching. Furthermore, RDVs and THVs with similar design characteristics were compared with each other.ResultsA total of 1,743 patients received SAVR with an RDV, whereas 14,730 patients were treated with transfemoral TAVR. Patients treated with TAVR were significantly older and had higher surgical risk scores. Following valve replacement, patients treated with an RDV had a significantly higher rate of disabling stroke (1.7% vs. 1.1%; p = 0.03), need for transfusion of >4 red blood cell units (8.5% vs. 1.4%; p < 0.001), and new onset renal replacement therapy (1.9% vs. 1.2%; p = 0.01), whereas the need for a new permanent pacemaker was lower (8.4% vs. 14.9%; p < 0.001). In-hospital mortality was similar (1.6% vs. 1.8%; p = 0.62). These findings persisted after 1:1 propensity score matching, but in-hospital mortality was significantly higher after RDVs (1.7% vs. 0.6%; p = 0.003). Balloon-expandable (BE) RDVs had significantly lower residual gradients compared with BE-THVs, while self-expanding (SE)-RDVs had significantly higher residual gradients compared with SE-THVs.ConclusionsIn a large all-comers’ registry, TAVR with current-generation THVs was associated with improved in-hospital outcomes compared with SAVR with current-generation RDVs. The pacemaker rate is significantly higher with TAVR. Post-procedural hemodynamic function varied between individual RDVs and THVs.  相似文献   

9.
ObjectivesThe aim of this study was to evaluate clinical outcomes and transcatheter heart valve hemodynamic parameters after transcatheter aortic valve replacement (TAVR) in low-risk patients with bicuspid aortic stenosis (AS).BackgroundTAVR is approved for low-risk patients in the United States. However, patients with bicuspid AS were excluded from the randomized cohorts of the pivotal low-risk trials.MethodsThe LRT (Low Risk TAVR) trial was an investigator-initiated, prospective, multicenter study and was the first and only U.S. Food and Drug Administration–approved investigational device exemption trial to evaluate the feasibility of TAVR with either balloon-expandable or self-expanding valves in low-risk patients with bicuspid AS. The primary endpoint was all-cause mortality at 30 days. Baseline and follow-up echocardiography and computed tomography to detect leaflet thickening were analyzed in an independent core laboratory.ResultsSixty-one low-risk patients with symptomatic, severe AS and bicuspid aortic valves (78.3% Sievers type 1 morphology) underwent TAVR at 6 centers from 2016 to 2019. The mean age was 68.6 years, and 42.6% were men. At 30 days, there was zero mortality and no disabling strokes. The rate of new permanent pacemaker implantation was 13.1%; just 1 patient had a moderate paravalvular leak at 30 days. Hypoattenuated leaflet thickening was observed in 10% of patients at 30 days.ConclusionsTAVR appears to be safe in patients with bicuspid AS, with short length of hospital stay, zero mortality, and no disabling strokes at 30 days. Subclinical leaflet thrombosis was observed in a minority of patients at 30 days but did not appear to be associated with clinical events.  相似文献   

10.
BackgroundIt is unknown whether the sex difference whereby female transcatheter aortic valve replacement (TAVR) candidates had a lower risk profile, a higher incidence of in-hospital complications, but more favorable short- and long-term survival observed in tricuspid cohorts undergoing TAVR would persist in patients with bicuspid aortic valves (BAVs).ObjectivesThe aim of this study was to reexamine the impact of sex on outcomes following TAVR in patients with BAVs.MethodsIn this single-center study, patients with BAVs undergoing TAVR for severe aortic stenosis from 2012 to 2021 were retrospectively included. Baseline characteristics, aortic root anatomy, and in-hospital and 1-year valve hemodynamic status and survival were compared between sexes.ResultsA total of 510 patients with BAVs were included. At baseline, women presented with fewer comorbidities. Men had a greater proportion of Sievers type 1 BAV, higher calcium volumes (549.2 ± 408.4 mm3 vs 920.8 ± 654.3 mm3; P < 0.001), and larger aortic root structures. Women experienced more vascular complications (12.9% vs 4.9%; P = 0.002) and bleeding (11.1% vs 5.3%; P = 0.019) and higher residual gradients (16.9 ± 7.7 mm Hg vs 13.2 ± 6.4 mm Hg; P < 0.001), while men were more likely to undergo second valve implantations during index TAVR (6.3% vs 15.9%; P = 0.001). Death at 1 year was not significantly different between sexes (HR: 1.15; 95% CI: 0.56-2.35; P = 0.70). Bleeding (adjusted HR: 4.62; 95% CI: 1.51-14.12; P = 0.007) was the single independent predictor of 1-year death for women.ConclusionsIn patients with BAVs undergoing TAVR, women presented with fewer comorbidities, while men had a greater proportion of type 1 BAV, more calcification, and larger aortic roots. In-hospital outcomes favored men, with fewer complications except for the need for second valve implantation, but 1-year survival was comparable between sexes.  相似文献   

11.
BackgroundPatients with rheumatic aortic stenosis (AS) were excluded from transcatheter aortic valve replacement (TAVR) trials.ObjectivesThe authors sought to examine outcomes with TAVR versus surgical aortic valve replacement (SAVR) in patients with rheumatic AS, and versus TAVR in nonrheumatic AS.MethodsThe authors identified Medicare beneficiaries who underwent TAVR or SAVR from October 2015 to December 2017, and then identified patients with rheumatic AS using prior validated International Classification of Diseases, Version 10 codes. Overlap propensity score weighting analysis was used to adjust for measured confounders. The primary study outcome was all-cause mortality. Multiple secondary outcomes were also examined.ResultsThe final study cohort included 1,159 patients with rheumatic AS who underwent aortic valve replacement (SAVR, n = 554; TAVR, n = 605), and 88,554 patients with nonrheumatic AS who underwent TAVR. Patients in the SAVR group were younger and with lower prevalence of most comorbidities and frailty scores. After median follow-up of 19 months (interquartile range: 13 to 26 months), there was no difference in all-cause mortality with TAVR versus SAVR (11.2 vs. 7.0 per 100 person-year; adjusted hazard ratio: 1.53; 95% confidence interval: 0.84 to 2.79; p = 0.2). Compared with TAVR in nonrheumatic AS, TAVR for rheumatic AS was associated with similar mortality (15.2 vs. 17.7 deaths per 100 person-years (adjusted hazard ratio: 0.87; 95% confidence interval: 0.68 to 1.09; p = 0.2) after median follow-up of 17 months (interquartile range: 11 to 24 months). None of the rheumatic TAVR patients, <11 SAVR patients, and 242 nonrheumatic TAVR patients underwent repeat aortic valve replacement (124 redo-TAVR and 118 SAVR) at follow-up.ConclusionsCompared with SAVR, TAVR could represent a viable and possibly durable option for patients with rheumatic AS.  相似文献   

12.
ObjectivesThe aim of this study was to evaluate early results of valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) versus redo surgical aortic valve replacement (SAVR) for structural valve degeneration (SVD).BackgroundViV TAVR has been increasingly used for SVD, but it remains unknown whether it produces better or at least comparable results as redo SAVR.MethodsObservational studies comparing ViV TAVR and redo SAVR were identified in a systematic search of published research. Random-effects meta-analysis was performed, comparing clinical outcomes between the 2 groups.ResultsTwelve publications including a total of 16,207 patients (ViV TAVR, n = 8,048; redo SAVR, n = 8,159) were included from studies published from 2015 to 2020. In the pooled analysis, ViV TAVR was associated with lower rates of 30-day mortality overall (odds ratio [OR]: 0.52; 95% confidence interval [CI]: 0.39 to 0.68; p < 0.001) and for matched populations (OR: 0.419; 95% CI: 0.278 to 0.632; p = 0.003), major bleeding (OR 0.48; 95% CI: 0.28 to 0.80; p = 0.013), as well as with shorter hospital stay (OR: ?3.30; 95% CI: ?4.52 to ?2.08; p < 0.001). In contrast, ViV TAVR was associated with higher rates of severe patient-prosthesis mismatch (OR: 4.63; 95% CI: 3.05 to 7.03; p < 0.001). The search revealed an important lack of comparative studies with long-term results.ConclusionsViV TAVR is a valuable option in the treatment of patients with SVD because of its lower incidence of post-operative complications and better early survival compared with redo SAVR. However, ViV TAVR is associated with higher rates of myocardial infarction and severe patient-prosthesis mismatch.  相似文献   

13.
BackgroundTranscatheter aortic valve replacement (TAVR) use is increasing in patients with longer life expectancy, yet robust data on the durability of transcatheter heart valves (THVs) are limited. Redo-TAVR may play a key strategy in treating patients in whom THVs fail.ObjectivesThe authors sought to examine outcomes following redo-TAVR.MethodsThe Redo-TAVR registry collected data on consecutive patients who underwent redo-TAVR at 37 centers. Patients were classified as probable TAVR failure or probable THV failure if they presented within or beyond 1 year of their index TAVR, respectively.ResultsAmong 63,876 TAVR procedures, 212 consecutive redo-TAVR procedures were identified (0.33%): 74 within and 138 beyond 1 year of the initial procedure. For these 2 groups, TAVR-to-redo-TAVR time was 68 (38 to 154) days and 5 (3 to 6) years. The indication for redo-TAVR was THV stenosis in 12 (16.2%) and 51 (37.0%) (p = 0.002) and regurgitation or combined stenosis–regurgitation in 62 (83.8%) and 86 (62.3%) (p = 0.028), respectively. Device success using VARC-2 criteria was achieved in 180 patients (85.1%); most failures were attributable to high residual gradients (14.1%) or regurgitation (8.9%). At 30-day and 1-year follow-up, residual gradients were 12.6 ± 7.5 mm Hg and 12.9 ± 9.0 mm Hg; valve area 1.63 ± 0.61 cm2 and 1.51 ± 0.57 cm2; and regurgitation ≤mild in 91% and 91%, respectively. Peri-procedural complication rates were low (3 stroke [1.4%], 7 valve malposition [3.3%], 2 coronary obstruction [0.9%], 20 new permanent pacemaker [9.6%], no mortality), and symptomatic improvement was substantial. Survival at 30 days was 94.6% and 98.5% (p = 0.101) and 83.6% and 88.3% (p = 0.335) at 1 year for patients presenting with early and late valve dysfunction, respectively.ConclusionsRedo-TAVR is a relatively safe and effective option for selected patients with valve dysfunction after TAVR. These results are important for applicability of TAVR in patients with long life expectancy in whom THV durability may be a concern.  相似文献   

14.
ObjectivesThe aim of this study was to compare outcomes after transcatheter aortic valve replacement (TAVR) with the SAPIEN 3 Ultra (Ultra) and SAPIEN 3 (S3) transcatheter heart valves (THVs).BackgroundThe latest generation balloon-expandable Ultra THV incorporates new technical features and might improve outcomes following TAVR.MethodsThis registry included all consecutive patients who underwent TAVR with either the Ultra or S3 between January 2014 and January 2020. One-to-one propensity score matching was performed to account for differences in baseline characteristics. In-hospital and 30-day Valve Academic Research Consortium-2–defined outcomes were investigated.ResultsA total of 310 patients (n = 155 Ultra, n = 155 S3) were included. There were no significant differences in baseline characteristics after propensity score matching. Procedures were significantly more often performed under conscious sedation with Ultra compared with S3 (97.4% vs. 71.6%; p < 0.001). Pre-dilatation was more frequent with S3 compared with Ultra (85.2% vs. 42.6%; p < 0.001). In-hospital outcomes, including device success (91.6% vs. 95.5%; p = 0.165), major vascular complications (12.3% vs. 11.0%; p = 0.723), and new pacemaker implantation (5.8% vs. 4.5%; p = 0.608), were comparable between S3 and Ultra patients, respectively. Post-procedural mean transprosthetic gradients (13.2 ± 5.7 mm Hg vs. 13.1 ± 4.7 mm Hg; p = 0.829) and rate of moderate or greater paravalvular leakage (PVL) (1.3% vs. 2.7%; p = 0.414) were comparable, whereas mild PVL was more frequent with S3 compared with Ultra (43.0% vs. 18.7%; p < 0.001).ConclusionsDevice success rates were high with both balloon-expandable THVs, with overall low rates of adverse events up to 30 days after TAVR. Despite a lower frequency of pre-dilatation, significant reduction of mild PVL confirms improved annular sealing properties of the novel Ultra THV.  相似文献   

15.
Transcatheter aortic valve replacement (TAVR) is increasingly being performed in younger and lower surgical risk patients. Given the longer life expectancy of these patients, the bioprosthetic valve will eventually fail, and aortic valve reintervention may be necessary. Although currently rare, redo-TAVR will likely increase in the future as younger patients are expected to outlive their transcatheter bioprosthesis. This review provides a contemporary overview of the indications, procedural planning, implantation technique, and outcomes of TAVR in failed transcatheter bioprosthetic aortic valves.  相似文献   

16.
BackgroundThe latest iterations of devices for transcatheter aortic valve replacement (TAVR) have brought refinements to further improve patient outcomes.ObjectivesThis study sought to compare early outcomes of patients undergoing TAVR with the self-expanding (SE) Evolut PRO/PRO+ (Medtronic, Inc) or balloon-expandable (BE) Sapien 3 ULTRA (Edwards Lifesciences) devices.MethodsThe OPERA-TAVI (Comparative Analysis of Evolut PRO vs Sapien 3 Ultra Valves for Transfemoral Transcatheter Aortic Valve Implantation) registry collected data from 14 high-volume centers worldwide on patients undergoing TAVR with SE or BE devices. After excluding patients who were not eligible for both devices, patients were compared using 1:1 propensity score matching. The primary efficacy and safety outcomes were Valve Academic Research Consortium-3 device success and early safety, respectively.ResultsAmong 2,241 patients eligible for the present analysis, 683 pairs of patients were matched. The primary efficacy outcome did not differ between patients receiving SE or BE transcatheter aortic valves (SE: 87.4% vs BE: 85.9%; P = 0.47), but the BE device recipients showed a higher rate of the primary safety outcome (SE: 69.1% vs BE: 82.6%; P < 0.01). This finding was driven by the higher rates of permanent pacemaker implantation (SE: 17.9% vs BE: 10.1%; P < 0.01) and disabling stroke (SE: 2.3% vs BE: 0.7%; P = 0.03) in SE device recipients. On post-TAVR echocardiography, the rate of moderate to severe paravalvular regurgitation was similar between groups (SE: 3.2% vs BE: 2.3%; P = 0.41), whereas lower mean transvalvular gradients were observed in the SE cohort (median SE: 7.0 vs BE: 12.0 mm Hg; P < 0.01).ConclusionsThe OPERA-TAVI registry showed that SE and BE devices had comparable Valve Academic Research Consortium-3 device success rates, but the BE device had a higher rate of early safety. The higher permanent pacemaker implantation and disabling stroke rates in SE device recipients drove this composite endpoint.  相似文献   

17.
ObjectivesA large comprehensive analysis of transcatheter aortic valve replacement (TAVR) was performed for failed stentless bioprostheses.BackgroundValve-in-valve (ViV) transcatheter aortic replacement (TAVR) is an alternative to redo surgery for patients with a failing aortic bioprosthesis.MethodsUnadjusted outcome data were collected from the VIVID (Valve-in-Valve International Data) registry between 2007 and 2016 from a total of 1,598 aortic ViV procedures (291 stentless, 1,307 stented bioprostheses).ResultsBioprosthetic failure was secondary to aortic regurgitation in 56% of stentless and 20% stented devices (p < 0.001). ViV-TAVR access was transfemoral in 71.1% stentless and 74.2% stented ViV-TAVR. Self-expanding devices were more frequently used in stentless ViV-TAVR (56.0% vs. 39.9%; p = 0.05), but there was no difference between balloon-expanding and self-expanding TAVR devices for stented ViV-TAVR (48.6% vs. 45.1%). The degree of oversizing for all mechanisms of bioprosthesis failure was 9 ± 10% for stentless ViV-TAVR vs. 6 ± 9% for stented ViV-TAVR (and 8 ± 10% for stentless ViV-TAVR vs. 3 ± 9% for stented ViV-TAVR in patients with predominant aortic regurgitation; both p < 0.001). Initial device malposition (10.3% vs. 6.2%; p = 0.014), second transcatheter device (7.9% vs. 3.4%), coronary obstruction (6.0% vs. 1.5%), and paravalvular leak occurred more frequently in stentless ViV-TAVR (all p < 0.001). Hospital stay duration (median 7 days) was no different, and 30-day (6.6% vs. 4.4%; p = 0.12) and 1-year mortality year (15.8% vs. 12.6%; p = 0.15) were numerically higher, but not statistically different, after stentless ViV-TAVR.ConclusionsStentless ViV-TAVR is associated with greater periprocedural complications (initial device malposition, second transcatheter device, coronary obstruction, paravalvular leak), but no difference in 30-day and 1-year outcome.  相似文献   

18.
BackgroundPermanent pacemaker implantation (PPI) remains one of the main drawbacks of transcatheter aortic valve replacement (TAVR), but scarce data exist on PPI after valve-in-valve (ViV) TAVR, particularly with the use of newer-generation transcatheter heart valves (THVs).ObjectivesThe goal of this study was to determine the incidence, factors associated with, and clinical impact of PPI in a large series of ViV-TAVR procedures.MethodsData were obtained from the multicenter VIVID Registry and included the main baseline and procedural characteristics, in-hospital and late (median follow-up: 13 months [interquartile range: 3 to 41 months]) outcomes analyzed according to the need of periprocedural PPI. All THVs except CoreValve, Cribier-Edwards, Sapien, and Sapien XT were considered to be new-generation THVs.ResultsA total of 1,987 patients without prior PPI undergoing ViV-TAVR from 2007 to 2020 were included. Of these, 128 patients (6.4%) had PPI after TAVR, with a significant decrease in the incidence of PPI with the use of new-generation THVs (4.7% vs. 7.4%; p = 0.017), mainly related to a reduced PPI rate with the Evolut R/Pro versus CoreValve (3.7% vs. 9.0%; p = 0.002). There were no significant differences in PPI rates between newer-generation balloon- and self-expanding THVs (6.1% vs. 3.9%; p = 0.18). In the multivariable analysis, older age (odds ratio [OR]: 1.05 for each increase of 1 year; 95% confidence interval [CI]: 1.02 to 1.07; p = 0.001), larger THV size (OR: 1.10; 95% CI: 1.01 to 1.20; p = 0.02), and previous right bundle branch block (OR: 2.04; 95% CI: 1.00 to 4.17; p = 0.05) were associated with an increased risk of PPI. There were no differences in 30-day mortality between the PPI (4.7%) and no-PPI (2.7%) groups (p = 0.19), but PPI patients exhibited a trend toward higher mortality risk at follow-up (hazard ratio: 1.39; 95% CI: 1.02 to 1.91; p = 0.04; p = 0.08 after adjusting for age differences between groups).ConclusionsIn a contemporary large series of ViV-TAVR patients, the rate of periprocedural PPI was relatively low, and its incidence decreased with the use of new-generation THV systems. PPI following ViV-TAVR was associated with a trend toward increased mortality at follow-up.  相似文献   

19.
ObjectivesThe aim of this study was to examine whether hospital surgical aortic valve replacement (SAVR) volume was associated with corresponding transcatheter aortic valve replacement (TAVR) outcomes.BackgroundRecent studies have demonstrated a volume-outcome relationship for TAVR.MethodsIn total, 208,400 fee-for-service Medicare beneficiaries were analyzed for all aortic valve replacement procedures from 2012 to 2015. Claims for patients <65 years of age, concomitant coronary artery bypass grafting surgery, other heart valve procedures, or other major open heart procedures were excluded, as were secondary admissions for aortic valve replacement. Hospital SAVR volumes were stratified on the basis of mean annual SAVR procedures during the study period. The primary outcomes were 30-day and 1-year post-operative TAVR survival. Adjusted survival following TAVR was assessed using multivariate Cox regression.ResultsA total of 65,757 SAVR and 42,967 TAVR admissions were evaluated. Among TAVR procedures, 21.7% (n = 9,324) were performed at hospitals with <100 (group 1), 35.6% (n = 15,298) at centers with 100 to 199 (group 2), 22.9% (n = 9,828) at centers with 200 to 299 (group 3), and 19.8% (n = 8,517) at hospitals with ≥300 SAVR cases/year (group 4). Compared with group 4, 30-day TAVR mortality risk-adjusted odds ratios were 1.32 (95% confidence interval: 1.18 to 1.47) for group 1, 1.25 (95% confidence interval: 1.12 to 1.39) for group 2, and 1.08 (95% confidence interval: 0.82 to 1.25) for group 3. These adjusted survival differences in TAVR outcomes persisted at 1 year post-procedure.ConclusionsTotal hospital SAVR volume appears to be correlated with TAVR outcomes, with higher 30-day and 1-year mortality observed at low-volume centers. These data support the importance of a viable surgical program within the heart team, and the use of minimum SAVR hospital thresholds may be considered as an additional metric for TAVR performance.  相似文献   

20.
ObjectivesThis study sought to evaluate the trends and outcomes of transcatheter aortic valve replacement (TAVR) versus surgical aortic valve replacement (SAVR) among patients with prior mediastinal radiation from a national database.BackgroundThere is a paucity of data about the temporal trends and outcomes of TAVR versus SAVR in patients with prior mediastinal radiation.MethodsThe National Inpatient Sample database years 2012 to 2017 was queried for hospitalizations of patients with prior mediastinal radiation who underwent isolated AVR. Using multivariable analysis, the study compared the outcomes of TAVR versus SAVR. The main study outcome was in-hospital mortality.ResultsThe final analysis included 3,675 hospitalizations for isolated AVR; of whom 2,170 (59.1%) underwent TAVR and 1,505 (40.9%) underwent isolated SAVR. TAVR was increasingly performed over time (ptrend = 0.01), but there was no significant increase in the rates of utilization of SAVR. The following factors were independently associated with TAVR utilization: older age, chronic lung disease, coronary artery disease, chronic kidney disease, prior cerebrovascular accidents, prior coronary artery bypass grafting, and larger-sized hospitals, while women were less likely to undergo TAVR. Compared with SAVR, TAVR was associated with lower in-hospital mortality (1.2% vs. 2.0%, adjusted odds ratio: 0.27; 95% confidence interval: 0.09 to 0.79; p = 0.02). TAVR was associated with lower rates of acute kidney injury, use of mechanical circulatory support, bleeding and respiratory complications, and shorter length of hospital stay. TAVR was associated with higher rates of pacemaker insertion.ConclusionsThis nationwide observational analysis showed that TAVR is increasingly performed among patients with prior mediastinal radiation. TAVR provides an important treatment option for this difficult patient population with desirable procedural safety when using SAVR as a benchmark.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号