共查询到20条相似文献,搜索用时 31 毫秒
1.
《JACC: Cardiovascular Interventions》2020,13(5):554-564
ObjectivesThe interference of a transtricuspid cardiac implantable electronic device (CIED) lead with tricuspid valve function may contribute to the mechanism of tricuspid regurgitation (TR) and poses specific therapeutic challenges during transcatheter tricuspid valve intervention (TTVI). Feasibility and efficacy of TTVI in presence of a CIED is unclear.BackgroundFeasibility of TTVI in presence of a CIED lead has never been proven on a large basis.MethodsThe study population consisted of 470 patients with severe symptomatic TR from the TriValve (Transcatheter Tricuspid Valve Therapies) registry who underwent TTVI at 21 centers between 2015 and 2018. The association of CIED and outcomes were assessed.ResultsPre-procedural CIED was present in 121 of 470 (25.7%) patients. The most frequent location of the CIED lead was the posteroseptal commissure (44.0%). As compared with patients without a transvalvular lead (no-CIED group), patients having a tricuspid lead (CIED group) were more symptomatic (New York Heart Association functional class III to IV in 95.9% vs. 92.3%; p = 0.02) and more frequently had previous episodes of right heart failure (87.8% vs. 69.0%; p = 0.002). No-CIED patients had more severe TR (effective regurgitant orifice area 0.7 ± 0.6 cm2 vs. 0.6 ± 0.3 cm2; p = 0.02), but significantly better right ventricular function (tricuspid annular plane systolic excursion = 16.7 ± 5.0 mm vs. 15.9 ± 4.0 mm; p = 0.04). Overall, 373 patients (79%) were treated with the MitraClip (Abbott Vascular, Santa Clara, California) (106 [87.0%] in the CIED group). Among them, 154 (33%) patients had concomitant transcatheter mitral repair (55 [46.0%] in the CIED group, all MitraClip). Procedural success was achieved in 80.0% of no-CIED patients and in 78.6% of CIED patients (p = 0.74), with an in-hospital mortality of 2.9% and 3.7%, respectively (p = 0.70). At 30 days, residual TR ≤2+ was observed in 70.8% of no-CIED and in 73.7% of CIED patients (p = 0.6). Symptomatic improvement was observed in both groups (NYHA functional class I to II at 30 days: 66.0% vs. 65.0%; p = 0.30). Survival at 12 months was 80.7 ± 3.0% in the no-CIED patients and 73.6 ± 5.0% in the CIED patients (p = 0.30).ConclusionsTTVI is feasible in selected patients with CIED leads and acute procedural success and short-term clinical outcomes are comparable to those observed in patients without a transtricuspid lead. 相似文献
2.
《JACC: Cardiovascular Interventions》2020,13(21):2482-2493
ObjectivesThe aim of this registry was to evaluate the feasibility and safety of transcatheter tricuspid valve implantation (TTVI) in patients with extreme surgical risk.BackgroundIsolated tricuspid regurgitation (TR) surgery is associated with high in-hospital mortality.MethodsThirty consecutive patients (mean age 75 ± 10 years; 56% women) from 10 institutions, with symptomatic functional TR, had institutional and notified body approval for compassionate use of the GATE TTVI system. Baseline, discharge, and 30-day follow-up echocardiographic data and procedural, in-hospital, and follow-up clinical outcomes were collected.ResultsAt baseline, all patients had multiple comorbidities, severe or greater TR, and reduced baseline right ventricular function. Technical success was achieved in 26 of 30 patients (87%). Device malpositioning occurred in 4 patients, with conversion to open heart surgery in 2 (5%). Of those who received the device, 100% had reductions in TR of ≥1, and 75% experienced reductions of ≥2 grades, resulting in 18 of 24 of patients (76%) with mild or less TR at discharge. All patients had mild or less central TR. There was continued improvement in TR grade between discharge and 30 days in 15 of 19 patients (79%). In-hospital mortality was 10%. At mean follow-up of 127 ± 82 days, 4 patients (13%) had died. Of patients alive at follow-up, 62% were in New York Heart Association functional class I or II, with no late device-related adverse events.ConclusionsCompassionate treatment of severe, symptomatic functional TR using a first-generation TTVI device is associated with significant reduction in TR and improvement in functional status with acceptable in-hospital mortality. Further studies are needed to determine the appropriate patient population and long-term outcomes with TTVI therapy. 相似文献
3.
《JACC: Cardiovascular Interventions》2020,13(17):1999-2009
ObjectivesThe aim of this study was to assess the clinical outcome of baseline massive or torrential tricuspid regurgitation (TR) after transcatheter tricuspid valve intervention (TTVI).BackgroundThe use of TTVI to treat symptomatic severe TR has been increasing rapidly, but little is known regarding the impact of massive or torrential TR beyond severe TR.MethodsThe study population comprised 333 patients with significant symptomatic TR from the TriValve Registry who underwent TTVI. Mid-term outcomes after TTVI were assessed according to the presence of massive or torrential TR, defined as vena contracta width ≥14 mm. Procedural success was defined as patient survival after successful device implantation and delivery system retrieval, with residual TR ≤2+. The primary endpoint comprised survival rate and freedom from rehospitalization for heart failure, survival rate, and rehospitalization at 1 year.ResultsBaseline massive or torrential TR and severe TR were observed in 154 patients (46.2%) and 179 patients (53.8%), respectively. Patients with massive or torrential TR had a higher prevalence of ascites than those with severe TR (27.3% vs. 20.4%, respectively; p = 0.15) and demonstrated a similar procedural success rate (83.2% vs. 77.3%, respectively; p = 0.21). The incidence of peri-procedural adverse events was low, with no significant between-group differences. Freedom from the composite endpoint was significantly lower in patients with massive or torrential TR than in those with severe TR, which was significantly associated with an increased risk for 1-year death of any cause or rehospitalization for heart failure (adjusted hazard ratio: 1.91; 95% confidence interval: 1.10 to 3.34; p = 0.022). Freedom from the composite endpoint was significantly higher in patients with massive or torrential TR when procedural success was achieved (69.9% vs. 54.2%, p = 0.048).ConclusionsBaseline massive or torrential TR is associated with an increased risk for all-cause mortality and rehospitalization for heart failure 1 year after TTVI. Procedural success is related to better outcomes, even in the presence of baseline massive or torrential TR. (International Multisite Transcatheter Tricuspid Valve Therapies Registry [TriValve]; NCT03416166) 相似文献
4.
《JACC: Cardiovascular Imaging》2022,15(6):961-970
BackgroundIn patients with severe primary mitral regurgitation (MR), the indication for surgery is currently based on the presence of symptoms, left ventricular dilatation and dysfunction, atrial fibrillation, and pulmonary hypertension.ObjectivesThe aim of this study was to evaluate the prognostic impact of the presence of extra–mitral valve cardiac involvement (including known risk factors but also severe left atrial [LA] dilatation and right ventricular [RV] dysfunction) in a large multicenter study of patients with primary MR.MethodsPatients with severe primary MR undergoing surgery were included and categorized according to the extent (highest) of cardiac involvement: group 0, no cardiac involvement; group 1, left ventricular involvement; group 2, LA involvement; group 3, pulmonary vasculature or tricuspid valve involvement; or group 4, RV involvement. The outcome was all-cause mortality.ResultsA total of 1,106 patients were included (mean age 63 ± 12 years, 68% male). In total, 377 patients (34%) were classified in group 0, 239 (22%) in group 1, 213 (19%) in group 2, 180 (16%) in group 3, and 97 (9%) in group 4. Kaplan-Meier curve analysis revealed significantly worse survival (log-rank chi-square = 43.4; P < 0.001) with higher group. On multivariable analysis, age, male sex, chronic obstructive pulmonary disease, kidney function, and group of cardiac involvement were independently associated with all-cause mortality. For each increase in group, a 17% higher risk for all-cause mortality was observed (95% CI: 1.051-1.313; P = 0.005) during a median follow-up time of 88 months.ConclusionsIn patients with severe primary MR, a novel classification system based on extra–mitral valve cardiac involvement may help refine risk stratification and timing of surgery, particularly including severe LA dilatation and RV dysfunction in the assessment. 相似文献
5.
《JACC: Cardiovascular Interventions》2020,13(21):2497-2507
ObjectivesThe aim of this study was to investigate the prevalence and prognostic impact of tricuspid annular dilatation (TAD) measured in multislice computed tomography datasets in patients undergoing transfemoral transcatheter aortic valve replacement for severe aortic stenosis.BackgroundTAD is an increasingly recognized entity associated with poor outcomes in patients with valvular heart disease.MethodsThe maximal septolateral diameter of the tricuspid annulus was measured in consecutive patients with 3-dimensional multidetector row computed tomographic datasets undergoing transfemoral transcatheter aortic valve replacement. Receiver-operating curve characteristic analysis was performed to obtain an ideal, body surface area–normalized cutoff for TAD. Ethical approval was obtained from the institutional ethics board.ResultsThe study included 1,137 patients, of whom 299 died within a mean follow-up period of 1.8 ± 1.0 years. TAD was identified in 446 patients (39.2%) on the basis of a receiver-operating characteristic cutoff of 23 mm/m2. TAD had no impact on procedural outcomes, including device failure defined according to Valve Academic Research Consortium–2 criteria. Patients with TAD experienced significantly greater mortality (hazard ratio: 1.99; 95% confidence interval: 1.59 to 2.51; p < 0.001). Multivariate analysis including clinical and echocardiographic parameters confirmed the predictive value of TAD (hazard ratio: 1.78; 95% confidence interval: 1.33 to 2.38; p < 0.001), while echocardiographic variables, including estimated pulmonary artery pressure and the severity of tricuspid regurgitation, did not reach statistical significance. The predictive value of TAD was incremental to a baseline model of clinical and echocardiographic parameters (continuous net reclassification improvement 0.204; p < 0.01) and incremental to the Society of Thoracic Surgeons score (continuous net reclassification improvement 0.209; p < 0.001).ConclusionsTAD is an independent predictor of all-cause mortality in patients with severe aortic stenosis undergoing transcatheter aortic valve replacement. 相似文献
6.
《JACC: Cardiovascular Interventions》2021,14(20):2285-2295
ObjectivesThe aim of this study was to assess the pooled clinical and echocardiographic outcomes of different isolated transcatheter tricuspid valve repair (ITTVR) strategies for significant (moderate or greater) tricuspid regurgitation (TR).BackgroundSignificant TR is a common valvular heart disease worldwide.MethodsPublished research was systematically searched for studies evaluating the efficacy and safety of ITTVR for significant TR in adults. The primary outcomes were improvement in New York Heart Association (NYHA) functional class and 6-minute walking distance and the presence of severe or greater TR at the last available follow-up of each individual study. Random-effect meta-analysis was performed comparing outcomes before and after ITTVR.ResultsFourteen studies with 771 patients were included. The mean age was 77 ± 8 years, and the mean European System for Cardiac Operative Risk Evaluation II score was 6.8% ± 5.4%. At a weighted mean follow-up of 212 days, 209 patients (35%) were in NYHA functional class III or IV compared with 586 patients (84%) at baseline (risk ratio: 0.23; 95% CI: 0.13-0.40; P < 0.001). Six-minute walking distance significantly improved from 237 ± 113 m to 294 ± 105 m (mean difference +50 m; 95% CI: +34 to +66 m; P < 0.001). One hundred forty-seven patients (24%) showed severe or greater TR after ITTVR compared with 616 (96%) at baseline (risk ratio: 0.29; 95% CI: 0.20-0.42; P < 0.001).ConclusionsPatients undergoing ITTVR for significant TR experienced significant improvements in NYHA functional status and 6-minute walking distance and a significant reduction in TR severity at mid-term follow-up. 相似文献
7.
《JACC: Cardiovascular Interventions》2022,15(5):481-491
ObjectivesThe aim of this study was to report the midterm outcomes at 1 year in the expanded first-in-human experience with the transfemoral EVOQUE system (Edwards Lifesciences) for tricuspid regurgitation (TR).BackgroundUntreated TR is associated with excess mortality and morbidity. The first-in-human experience with the EVOQUE tricuspid valve replacement system reported favorable 30-day outcomes with no mortality in a compassionate use population.MethodsTwenty-seven patients with severe TR were treated with the EVOQUE system in a compassionate use experience at 7 centers between May 2019 and July 2020. All patients had clinical right-sided heart failure (HF) and were deemed inoperable and unsuitable for transcatheter edge-to-edge repair by the institutional heart teams. The clinical outcomes collected included all-cause mortality, symptom status, TR severity, HF hospitalization, and major adverse cardiovascular events.ResultsAt baseline, all patients (age: 77 ± 8 years, 89% female) were at high surgical risk (mean Society of Thoracic Surgeons score: 8.6% ± 5.5%), with 89% New York Heart Association functional class III/IV. TR was predominantly functional in etiology (19/27, 70%). At 1 year, mortality was 7% (2/27), 70% of patients were New York Heart Association functional class I/II, and 96% and 87% of patients had a TR grade ≤2+ and ≤1+, respectively. Between 30 days and 1 year, 2 patients experienced HF hospitalizations, and 1 patient required a new pacemaker implantation.ConclusionsIn this early, compassionate use experience, the transfemoral transcatheter EVOQUE tricuspid valve replacement system demonstrated durable efficacy, persistent improvement in symptom status, and low rates of mortality and HF hospitalizations at a 1-year follow-up. Further studies are underway to validate its efficacy. 相似文献
8.
《Journal of the American College of Cardiology》2020,75(9):1033-1043
BackgroundTricuspid regurgitation (TR) is common among adults with corrected tetralogy of Fallot (TOF) or pulmonary stenosis (PS) referred for pulmonary valve replacement (PVR). Yet, combined valve surgery remains controversial.ObjectivesThis study sought to evaluate the impact of concomitant tricuspid valve intervention (TVI) on post-operative TR, length of hospital stay, and on a composite endpoint consisting of 7 early adverse events (death, reintervention, cardiac electronic device implantation, infection, thromboembolic event, hemodialysis, and readmission).MethodsThe national Canadian cohort enrolled 542 patients with TOF or PS and mild to severe TR who underwent isolated PVR (66.8%) or PVR+TVI (33.2%). Outcomes were abstracted from charts and compared between groups using multivariable logistic and negative binomial regression.ResultsMedian age at reintervention was 35.3 years. Regardless of surgery type, TR decreased by at least 1 echocardiographic grade in 35.4%, 66.9%, and 92.8% of patients with pre-operative mild, moderate, and severe insufficiency. In multivariable analyses, PVR+TVI was associated with an additional 2.3-fold reduction in TR grade (odds ratio [OR]: 0.44; 95% confidence interval [CI]: 0.25 to 0.77) without an increase in early adverse events (OR: 0.85; 95% CI: 0.46 to 1.57) or hospitalization time (incidence rate ratio: 1.17; 95% CI: 0.93 to 1.46). Pre-operative TR severity and presence of transvalvular leads independently predicted post-operative TR. In contrast, early adverse events were strongly associated with atrial tachyarrhythmia, extracardiac arteriopathy, and a high body mass index.ConclusionsIn patients with TOF or PS and significant TR, concomitant TVI is safe and results in better early tricuspid valve competence than isolated PVR. 相似文献
9.
《JACC: Cardiovascular Interventions》2020,13(17):2012-2020
ObjectivesThe aim of this study was to determine the prevalence of pacemaker lead–related complications following transcatheter tricuspid valve replacement (TTVR).BackgroundThe rate of permanent pacemaker implantation following tricuspid valve (TV) surgery is high, and many patients have transvenous leads. The feasibility, safety, and outcomes of subsequently performing TTVR in the setting of transvenous pacemaker leads have not been established.MethodsThe VIVID (Valve-in-Valve International Database) registry was used to review 329 patients who underwent TTVR following TV repair or replacement. Patients were subdivided into 3 cohorts for intergroup comparisons: no lead, epicardial lead, and transvenous lead (entrapped or not entrapped during the TTVR procedure).ResultsOf 329 patients who underwent TTVR, 128 (39%) had prior pacing systems in place, 70 with epicardial and 58 with transvenous leads. A total of 31 patients had leads passing through the TV. Three patients had the right ventricular (RV) lead extracted prior to TTVR. The remaining 28 patients had the RV lead entrapped between the transcatheter TV implant and the surgical valve (n = 22) or the repaired TV (n = 6). One patient had displacement of the RV lead during the procedure, and 2 experienced lead failure during follow-up. Overall, there was no significant difference in the cumulative incidences of competing outcomes (death, TV reintervention, TV dysfunction) between patients with and those without pacing leads or entrapped RV leads.ConclusionsTTVR in the setting of trans-TV pacemaker leads without lead extraction or re-replacement can be performed safely with a low risk for complications, offering an alternative to surgical TV replacement. 相似文献
10.
《JACC: Cardiovascular Interventions》2021,14(20):2274-2281
ObjectivesThe objective of this study was to determine the effect of transcatheter mitral valve repair (TMVr) on hospitalization rates by assessing pre- and postprocedural hospitalization patterns.BackgroundTMVr has emerged as the treatment of choice for selected patients with mitral regurgitation, but the impact of these procedures on hospital utilization remains unclear.MethodsAll patients who underwent TMVr in Ontario, Canada, between 2011 and 2017 were included in this observational study using population-based data. Hospitalization person-year rates were assessed in the years before and after TMVr and 4 predefined intervals: 1 to 30, 31 to 90, 91 to 182, and 183 to 365 days. Main outcomes of interest were all-cause and heart failure (HF) hospitalizations. Poisson regression models were used to compare incidence rates across all time periods.ResultsThe study cohort included 523 patients. In the year preceding TMVr, 66.2% of patients were hospitalized compared with 47.4% in the year following. There were stepwise increases in both all-cause and HF hospitalization rates in the periods preceding the index procedure, and all postprocedural periods had significantly lower hospitalization rates. The adjusted rate ratios for all-cause and HF-related hospitalization in the year after TMVr were 0.65 (95% CI: 0.56-0.76) and 0.38 (95% CI: 0.29-0.51), respectively. All time periods had significant reductions in all-cause and HF hospitalization in the adjusted analysis.ConclusionsIn this population-based study, significant reductions were observed in both all-cause and HF-related hospitalizations in all time periods after TMVr compared with the year prior. This suggests that TMVr has a sustained effect on hospitalization rates despite a high-risk population. 相似文献
11.
《JACC: Cardiovascular Interventions》2021,14(20):2260-2270
ObjectivesThis study aimed to assess the anatomical leaflet variation and investigate its impact on the procedural outcome in patients undergoing transcatheter edge-to-edge tricuspid repair.BackgroundTricuspid regurgitation (TR) is associated with a poor prognosis.MethodsThe study participants were consecutive patients who underwent transcatheter edge-to-edge tricuspid repair with the MitraClip, TriClip, or PASCAL systems from June 2015 to July 2020 at the Bonn Heart Center. The tricuspid leaflet morphologies were imaged using 2-dimensional and 3-dimensional transesophageal echocardiography. The severity of TR was assessed according to the 5-grade scheme. The primary endpoint was residual TR ≥3+ within 30 days.ResultsOf the 145 study participants, 103 (71.1%) participants were categorized as the 3-leaflet configuration, while 42 (28.9%) were categorized as the 4-leaflet configuration. Successful device implantation was achieved in 136 (93.8%) patients, with no statistical difference between the 3-leaflet and 4-leaflet configuration groups. However, compared with patients with a 3-leaflet configuration, patients with 4-leaflet configuration more frequently had residual TR ≥3+ (18.4% vs 38.1%; P = 0.018). In the multivariable model, the 4-leaflet configuration was associated with an increased risk of residual TR ≥3+ (odds ratio: 2.65; 95% CI 1.15-6.10; P = 0.022), independent of baseline TR grade, coaptation gap width, and TR jet location. After 1-year follow-up, compared with patients with residual TR <3+, patients with residual TR ≥3+ had a significantly higher incidence of the composite of all-cause mortality or heart failure hospitalization (27.7% vs 56.1%; P = 0.016).ConclusionsA 4-leaflet configuration of the tricuspid valve is observed in approximately one-third of patients undergoing transcatheter edge-to-edge tricuspid repair, which is associated with an increased risk of residual TR after the procedure. 相似文献
12.
《JACC: Cardiovascular Interventions》2020,13(13):1503-1514
As transcatheter aortic valve replacement becomes a more dominant treatment option across all risk profiles, the frequency of encountering patients with multivalvular disease will increase. Furthermore, percutaneous interventions to treat other valvular lesions are also evolving. Understanding the clinical implications and treatment options for a second valvular lesion is becoming increasingly important to guide heart team decisions, and this paper aims to review the evidence around these situations. Diagnosis of multivalvular disease can be challenging because of changes in physiology. There are little randomized data to guide therapy in multivalvular disease. Multidisciplinary heart team decisions can be invaluable in integrating the plethora of clinical, hemodynamic, and imaging data on which an optimal management strategy can be planned. Prospective studies to assess the role of structural valve interventions in the transcatheter aortic valve replacement era would greatly help improve outcomes for structural heart patients. 相似文献
13.
《JACC: Cardiovascular Interventions》2022,15(13):1352-1363
BackgroundTranscatheter treatment techniques for tricuspid regurgitation (TR) have evolved in recent years, with leaflet repair being the most commonly used, but thus far evidence on the PASCAL and PASCAL Ace system is based mainly on compassionate use data.ObjectivesThis is the first report on commercial use in a multicenter study with a large patient cohort investigating the safety and efficacy of the PASCAL and PASCAL Ace system in the treatment of TR.MethodsIn a retrospective, multicenter, observational setting, data from all consecutive patients undergoing leaflet repair for TR at 8 centers was collected, including a centralized analysis of echocardiographic data.ResultsA total of 235 high-risk patients (mean age 78 ± 8 years, 49% women, mean Society of Thoracic Surgeons Predicted Risk of Mortality score 8.6% ± 6.8%) were included. TR was functional in 87% of patients and graded severe or higher in 91%. TR was successfully reduced to moderate or less in 78% of patients (P < 0.001). Procedural success was 78% (n = 153). At the latest available follow-up (median 173 days), TR reduction was sustained (78% with TR moderate or less; P < 0.001), and echocardiography showed indications of right ventricular remodeling (mean right ventricular end-diastolic diameter 56 ± 9 mm vs 53 ± 9 mm; P < 0.001). Patients’ symptoms diminished significantly (63% were in New York Heart Association functional class I or II at follow-up; P < 0.001). In a device-specific analysis, the PASCAL and PASCAL Ace showed no difference in TR reduction (postprocedural TR moderate or less in 77% vs 78%; P = 0.82).ConclusionsIn early clinical experience, the PASCAL (Ace) leaflet repair system has high technical and procedural success rates with efficient TR reduction and significant clinical and echocardiographic improvement at follow-up. 相似文献
14.
《JACC: Cardiovascular Interventions》2022,15(5):471-480
ObjectivesThe TRISCEND study (Edwards EVOQUE Tricuspid Valve Replacement: Investigation of Safety and Clinical Efficacy after Replacement of Tricuspid Valve with Transcatheter Device) is evaluating the safety and performance of transfemoral transcatheter tricuspid valve replacement in patients with clinically significant tricuspid regurgitation (TR) and elevated surgical risk.BackgroundTranscatheter valve replacement could lead to a paradigm shift in treating TR and improving patient quality of life.MethodsIn the prospective, single-arm, multicenter TRISCEND study, patients with symptomatic moderate or greater TR, despite medical therapy, underwent percutaneous transcatheter tricuspid valve replacement with the EVOQUE system. A composite rate of major adverse events, echocardiographic parameters, and clinical, functional, and quality-of-life measures were assessed at 30 days.ResultsFifty-six patients (mean age of 79.3 years, 76.8% female, 91.1% TR severe or greater, 91.1% atrial fibrillation, and 87.5% New York Heart Association functional class III or IV) were treated. At 30 days, TR was reduced to mild or less in 98%. The composite major adverse events rate was 26.8% at 30 days caused by 1 cardiovascular death in a patient with a failed procedure, 2 reinterventions after device embolization, 1 major access site or vascular complication, and 15 severe bleeds, of which none were life-threatening or fatal. No myocardial infarction, stroke, renal failure, major cardiac structural complications, or device-related pulmonary embolism were observed. New York Heart Association significantly improved to functional class I or II (78.8%; P < 0.001), 6-minute walk distance improved 49.8 m (P < 0.001), and Kansas City Cardiomyopathy Questionnaire score improved 19 points (P < 0.001).ConclusionsEarly experience with the transfemoral EVOQUE system in patients with clinically significant TR demonstrated technical feasibility, acceptable safety, TR reduction, and symptomatic improvement at 30 days. The TRISCEND II randomized trial (NCT04482062) is underway. 相似文献
15.
《JACC: Cardiovascular Interventions》2022,15(12):1266-1274
BackgroundData on outcomes of transcatheter aortic valve replacement (TAVR) using balloon-expandable valves (BEVs) or self-expandable valves (SEVs) as well as the impact of center valve preference on these outcomes are limited.ObjectivesThe aim of this study was to compare outcomes of TAVR procedures using third-generation BEVs and SEVs stratified by center valve preference.MethodsIn a multicenter registry (n = 17), 13 centers exhibited valve preference (66.6%-90% of volume) and were included. Outcomes were compared between BEVs and SEVs stratified by center valve preference.ResultsIn total, 7,528 TAVR procedures (3,854 with SEVs and 3,674 with BEVs) were included. The mean age was 81 years, and the mean Society of Thoracic Surgeons score was 5.2. Baseline characteristics were similar between BEVs and SEVs. Need for pacemaker implantation was higher with SEVs at BEV- and SEV-dominant centers (17.8% vs 9.3% [P < 0.001] and 12.7% vs 10.0% [P = 0.036], respectively; HR: 1.51; P for interaction = 0.021), risk for cerebrovascular accident was higher with SEVs at BEV-dominant but not SEV-dominant centers (3.6% vs 1.1% [P < 0.001] and 2.2% vs 1.4% [P = 0.162]; HR: 2.08; P for interaction < 0.01). Aortic regurgitation greater than mild was more frequent with SEVs at BEV-dominant centers and similar with BEVs regardless of center dominance (5.2% vs 2.8% [P < 0.001] and 3.4% vs 3.7% [P = 0.504], respectively). Two-year mortality was higher with SEVs at BEV-dominant centers but not at SEV-dominant centers (21.9% vs 16.9% [P = 0.021] and 16.8% vs 16.5% [P = 0.642], respectively; HR: 1.20; P for interaction = 0.032).ConclusionsPeriprocedural outcomes, aortic regurgitation greater than mild, and 2-year mortality are worse when TAVR is performed using SEVs at BEV-dominant centers. Outcomes are similar regardless of valve type at SEV-dominant centers. The present results stress the need to account for this factor when comparing BEV and SEV outcomes. (The Aortic+Mitral Transcatheter [AMTRAC] Valve Registry; NCT04031274) 相似文献
16.
《JACC: Cardiovascular Interventions》2022,15(19):1936-1945
BackgroundLittle is known about the incidence and clinical relevance of postprocedural acute kidney injury (AKI) in patients undergoing transcatheter edge-to-edge repair (TEER) for tricuspid regurgitation (TR).ObjectivesThe aim of this study was to investigate the prognostic impact of postprocedural AKI following TEER for TR.MethodsTwo hundred sixty-eight patients who underwent TEER for TR at 2 centers were retrospectively analyzed. Postprocedural AKI was defined as an increase in serum creatinine of ≥0.3 mg/dL within 48 hours or ≥50% within 7 days after the procedure compared with baseline. The association between AKI and the composite outcome, consisting of all-cause mortality and rehospitalization for heart failure within 1 year after the procedure, was determined.ResultsThe mean age of the patients was 79.0 ± 6.8 years, and 43.3% were men. Postprocedural AKI occurred in 42 patients (15.7%). Age, male sex, an estimated glomerular filtration rate of <60 mL/min/1.73 m2, and absence of procedural success were associated with the occurrence of AKI. Patients with AKI had a higher incidence of in-hospital mortality than those without AKI (9.5% vs 0.9%; P = 0.006). Moreover, AKI was associated with the incidence of the composite outcome within 1 year after TEER for TR (adjusted HR: 2.39; 95% CI: 1.45-3.94; P = 0.001).ConclusionsPostprocedural AKI occurred in 15.7% of patients undergoing TEER for TR, despite the absence of iodinated contrast agents, which was associated with worse clinical outcomes. These findings highlight the clinical impact of AKI following TEER for TR and should help in identifying patients at high risk for AKI. 相似文献
17.
《JACC: Cardiovascular Interventions》2020,13(23):2719-2729
ObjectivesThe aim of this study was to assess the feasibility, efficacy, and clinical outcomes of transcatheter repair of tricuspid regurgitation (TR) in a pooled analysis of interventional studies.BackgroundNew percutaneous devices are available to treat severe TR, but the evidence is sparse and limited to smaller cohorts.MethodsSeveral electronic databases were searched for interventional studies involving percutaneous repair of TR. Devices used were the Cardioband, FORMA, MitraClip, PASCAL, and Trialign. Outcomes included in the final analysis were successful implantation, residual severe TR, post-procedural New York Heart Association (NYHA) functional class III or IV, 6-min walk distance, and echocardiographic parameters. Subgroup and meta-regression analysis were performed to further explore residual heterogeneity.ResultsSeven studies and 454 patients undergoing transcatheter tricuspid valve repair were included in the pooled analysis; 95% of patients had at least severe TR, and 91% were in NYHA functional class III or IV. Successful implantation was achieved in 86% of patients. At the longest follow-up available (weighted mean 265 days), 9% had died. Compared with baseline, a significantly lower proportion of patients had at least severe TR (relative risk: 0.38; 95% confidence interval: 0.20 to 0.70; p = 0.004) and were in NYHA functional class III or IV (relative risk: 0.23; 95% confidence interval: 0.20 to 0.30; p < 0.001). Patients also experienced increases in 6-min walk distance (mean difference +64.6 m; p < 0.001) and significant reductions in tricuspid valve annular diameter (mean difference −3 mm; p < 0.001), while left and right ventricular function did not change significantly.ConclusionsA strategy of transcatheter repair for severe TR appears to be feasible, effective, and associated with improved clinical outcomes at mid-term follow-up. 相似文献
18.
《JACC: Cardiovascular Interventions》2019,12(15):1403-1412
With explosive growth in the field of transcatheter therapies in recent years, transcatheter valve-in-valve implantation has rapidly emerged as a viable, low-risk alternative to high-risk redo surgical interventions. The authors review the fundamental clinical principles of transcatheter tricuspid valve-in-valve and valve-in-ring implantation as pertinent to the procedural steps and technique. 相似文献
19.
《JACC: Cardiovascular Imaging》2020,13(7):1461-1471
ObjectivesThe aim of this study was to compare echocardiographic methods of determining tricuspid regurgitation (TR) severity against TR regurgitant volume (TRRV) by cardiovascular magnetic resonance (CMR).BackgroundTR is usually assessed using echocardiography, but it is not known how this compares with quantitative measurements of TR severity by CMR.MethodsEchocardiographic and CMR methods were compared in 337 patients. Echocardiographic methods included jet size, hepatic vein flow, inferior vena cava diameter, percentage change in inferior vena cava diameter with inspiration, right atrial end-systolic area and volume, right ventricular end-diastolic and end-systolic areas and fractional area change, vena contracta diameter, effective regurgitant orifice area, and TRRV using the proximal isovelocity surface area method. TRRV by CMR was calculated as the difference between right ventricular end-diastolic and end-systolic volumes and systolic flow through the pulmonic valve.ResultsEchocardiographic parameters of TR severity had variable accuracy against TRRV by CMR (area under the curve range 0.58 for jet area/right atrial end-systolic area to 0.79 for hepatic vein flow). A multiparametric approach to assessing TR severity according to the 2017 American Society of Echocardiography criteria had 65% agreement with TR severity by CMR. A hierarchal approach based on signals with higher feasibility and accuracy against CMR had 68% agreement, without missing cases of severe TR by CMR. Agreement with CMR by the hierarchal approach was higher than that by the 2017 American Society of Echocardiography guidelines (p = 0.016).ConclusionsSeveral individual echocardiographic parameters of TR severity have satisfactory accuracy against TRRV by CMR. A multiparametric hierarchal approach resulted in 68% agreement with CMR and 100% agreement when a 1-grade difference in TR severity is considered acceptable. 相似文献
20.
《JACC: Cardiovascular Interventions》2022,15(17):1731-1740
BackgroundAtrial secondary mitral regurgitation (ASMR) is a subtype of SMR that has a poor prognosis, and thus far, evidence of the therapeutic options for the management of ASMR is limited.ObjectivesThis study aimed to investigate the effectiveness of transcatheter edge-to-edge repair (TEER) for ASMR.MethodsThe study retrospectively analyzed consecutive patients who underwent MitraClip at the Heart Center Bonn. ASMR was defined as cases that met all of the following criteria: 1) normal mitral leaflets without organic disorder; 2) left ventricular ejection fraction >50%; and 3) absence of LV enlargement and segmental abnormality. The primary outcome measure was MR reduction to ≤1+, and its predictors were explored in a logistic regression analysis.ResultsAmong 415 patients with SMR, 118 patients met the criteria for ASMR (mean age 80 ± 8 years, 39.8% male). The technical success rate was 94.1%, and MR reduction to ≤1+ after TEER was achieved in 94 (79.7%) patients with ASMR. The in-hospital mortality rate was 2.5%. In multivariable logistic analysis, a large left atrial volume index and low leaflet-to-annulus index were associated with a lower incidence of MR reduction to ≤1+ after TEER for ASMR. In addition, the use of a newer generation of the MitraClip systems (NTR/XTR or G4 systems) was associated with a higher incidence of MR reduction to ≤1+.ConclusionsTEER is a safe and feasible therapeutic option for patients with ASMR. Assessments of left atrial volume index and leaflet-to-annulus index may assist with patient selection for TEER in patients with ASMR. 相似文献