首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Microvascular reconstruction of head and neck defects can be extremely challenging in patients with a history of prior neck dissection and/or irradiation. We reviewed of 261 head and neck free flaps performed between 2004 and 2007 at a tertiary cancer center. One hundred twenty-four (52%) free flaps were performed in patients with a history of prior neck dissection and/or irradiation. The ipsilateral external carotid artery or one of its branches was not available in 43 (19%) cases: 13 with no history of prior neck dissection or irradiation, and 30 with a history of prior neck dissection and/or irradiation (P = 0.03). The ipsilateral internal/external jugular veins (IJ/EJ) were not available in 37 (16%) cases: 11 with no history of prior neck dissection or irradiation, and 26 with a history of prior neck dissection and/or irradiation (P = 0.002). Strategies for dealing with lack of a recipient vessels included anastomosis to contralateral neck vessels, transverse cervical vessels, internal mammary vessels, the cephalic vein, and the pedicle of another free flap. We propose an algorithm for locating recipient vessels adequate for microvascular anastomosis should the ipsilateral external carotid arterial and/or the internal/external jugular venous systems not be available, such as in the setting of prior neck dissection or irradiation.  相似文献   

2.
Graham BB  Varvares MA 《Head & neck》2004,26(6):537-540
BACKGROUND: Failure of free flaps is frequently because of failure of the venous vascular anastomosis. A new venous anastomosis technique that uses the stump of the internal jugular vein (IJV) is described, with preliminary data on operative outcomes. METHODS: Retrospective analysis of eight head and neck free flap operations in which a venous anastomosis to the stump of an IJV was used compared with 222 other free flap operations in the same period (1995-2001) at a single institution. RESULTS: None of the eight free flaps that used venous end-to-side anastomoses to the stump of an IJV failed. There were 15 failures associated with the other 222 venous microvascular anastomoses (6.8%). CONCLUSIONS: This new technique resulted in no failures in eight operations. Advantages of this technique include avoiding creating an anastomosis under tension or requiring a saphenous vein graft and reducing pedicle torsion at the hilum of the flap.  相似文献   

3.
Halvorson EG  Cordeiro PG 《Annals of plastic surgery》2007,59(1):31-5; discussion 35
Preferential use of end-to-side anastomosis to the internal jugular vein in head and neck reconstruction offers distinct advantages and has consistently yielded excellent outcomes. Presented is a series of 320 consecutive cases by a single surgeon at 1 institution over 10 years. The most common flaps employed were the rectus (33%), forearm (28%), and fibula (21%) flaps. The most common defects were the mandible +/- floor of mouth (27%), pharyngoesophagus (25%), and tongue or cheek (17% each). Minor wound-healing problems, infection, and hematoma were noted in 5% or less. Partial flap loss was seen in 2%. Total flap loss and arterial or venous thrombosis occurred in less than 1% of patients. The size, constant anatomy, patency, and possibility for multiple anastomoses make use of the internal jugular vein very advantageous. Kinking is not observed when the neck is rotated, and high patency rates can be expected.  相似文献   

4.
The authors report their experience with 80 head and neck reconstructions using free-tissue transfer in which end-to-side anastomosis with the internal jugular vein was carried out. An end-to-side anastomosis with the internal jugular vein has the following advantages. Firstly, the technique overcomes the problems of vessel size discrepancy. It is effectively applied for free jejunal transfer or combined flap transfer based on a single vascular pedicle, of which the size of the proximal end of the drainage vein is very large. Secondly, the internal jugular vein has wide capacity to be the recipient of two or more end-to-side anastomoses. It is effectively used for free radial forearm or rectus abdominis myocutaneous flaps in which two or more drainage veins can be included. Thirdly, the respiratory venous pump effect may act directly on the venous drainage of the transferred flap through the internal jugular vein. In our institution, these advantages have made it the technique of choice in head and neck reconstructive microsurgery.  相似文献   

5.
We prospectively evaluated success rate and complications associated with 436 internal (IJ) and external (EJ) jugular approaches to central venous cannulation in 377 paediatric patients. Variables studied included the route of insertion, success rate, cannulation time, intraoperative and postoperative catheter-related complications. The overall success rate and the frequency of complications were higher with the IJ than with the EJ approach. Cannulation with the EJ approach was more successful in older patients than in younger ones, making EJ a more attractive route for central venous cannulation in older children. While the inconsistent final position of the catheter tip makes EJ a less reliable technique for central venous pressure monitoring, it does not limit its usefulness for infusion of vasoactive drugs. If monitoring of filling pressures is desired, the IJ approach is a better choice, despite its higher risk of complications.  相似文献   

6.
目的 探讨分析3种游离股前外侧皮瓣在口腔软组织缺损修复中的临床特点与治疗效果。方法 2008年12月至2010年12月收治67例口腔肿瘤患者,切除肿瘤的同时,应用游离股前外侧皮瓣修复缺损处,包括舌、颊、牙龈、口底,通常将皮瓣的旋股外侧动脉降支与受区的颌外动脉或甲状腺上动脉吻合,伴行静脉与受区的面总静脉或颈外静脉吻合。根据游离股前外侧皮瓣的厚度将其分成3种类型:股前外侧肌皮瓣、股前外侧脂肪筋膜皮瓣和薄型股前外侧皮瓣。结果 67例中股前外侧肌皮瓣为35例,股前外侧脂肪筋膜皮瓣17例,薄型股前外侧皮瓣15例。66例皮瓣存活,成功率为98.5%,其中1例糖尿病患者皮瓣发生小部分坏死,经清创换药后痊愈;1例皮瓣完全坏死。67例皮瓣中41例吻合2条静脉,26例吻合1条静脉。8例出现血管危象:6例为静脉血栓(5例抢救成功、1例皮瓣完全坏死),1例为术区血肿,1例为穿支血管扭转,经过相应处理,血管危象均得到缓解。术后随访2~ 24个月,平均8.7个月,受区组织缺损修复效果满意,供区创面愈合良好。结论 游离股前外侧皮瓣的受区功能良好,供区并发症少,是一种修复口腔软组织缺损的较为理想的方法。  相似文献   

7.
The internal jugular vein has been the preferred recipient vein in head and neck microsurgical reconstruction. However, recent reports have demonstrated internal jugular vein occlusion after functional neck dissection. The purpose of this article is to demonstrate and discuss the possibility of recipient internal jugular vein occlusion after free tissue transfer. Of 58 patients who received an end-to-side venous anastomosis with the internal jugular vein, four cases of recipient internal jugular vein occlusion were detected during the early postoperative period. Although the success rate of end-to-side anastomosis with the internal jugular vein may be high, microsurgeons should be aware of the possibility of internal jugular vein occlusion.  相似文献   

8.
Microvascular free tissue transfer in head and neck reconstruction requires suitable recipient vessels which are frequently compromised by prior surgery or radiotherapy to the neck. This article details a new technique of arterial free flap pedicle anastomosis to the internal carotid artery in a vessel-depleted neck. A 63-year-old female was referred because of recurrence of squamous cell carcinoma of the tongue, which involved the left-sided tongue base and pharynx with circumferential involvement of the homolateral external carotid artery. This artery and its branches were excluded as potential recipients. To close the defect after tumor excision, a free vertical rectus abdominis muscle arterial flap pedicle was anastomosed to the homolateral internal carotid artery with the help of a Pruitt-Inahara outlying carotid shunt. The venous anastomosis was performed to the internal jugular vein. The VRAM flap survived without complications. This procedure is to be considered an alternative rescue technique for salvage reconstruction in vessel depleted necks.  相似文献   

9.
It has been postulated that venous thrombosis in free flap surgery necessitates the use of 2 venous anastomoses into different venous systems. We retrospectively analyzed a single surgeon's 10-year experience (August 1993 to August 2003) in primary free flap reconstruction for malignant tumors of the head and neck. Of 492 primary reconstructions that did not need a vein graft, vein loop, or cephalic turnover procedure, 251 used the internal jugular venous system as venous outflow, 140 used the subclavian system as outflow, and 101 used both. Two hundred thirty-eight of 251 (95%) of flaps utilizing the internal jugular venous system for outflow were successful compared with 129 of 140 (92%) of flaps utilizing the subclavian system. Where both venous systems were used the success rate was 101 of 101 (100%) (P < 0.05). Where possible, a second venous anastomosis should be performed utilizing both venous drainage systems.  相似文献   

10.
BACKGROUND: The internal mammary and thoracodorsal vessels are the standard recipient sites in microsurgical breast reconstruction. We review our series of venous outflow alternatives when these vessels are inadequate or unusable. MATERIALS AND METHODS: A retrospective review of all free breast reconstructions was performed from July 2003 through December 2005. Outcomes were measured with regard to re-exploration, flap failure, and fat necrosis, with attention to the timing and side of reconstruction, as well as the presence or absence of radiation therapy. RESULTS: A total of 141 free breast reconstructions were performed during the study period. In seven cases (5%), alternative venous outflow vessels were selected (cephalic or external jugular vein). Nine anastamotic complications occurred, all of which involved the left internal mammary group (statistically significant for venous thrombosis, P = 0.0063) and three flaps failed. All cephalic and external jugular veins remained patent with no flap failures or fat necrosis within this group. CONCLUSION: The cephalic vein and external jugular vein are excellent alternatives for venous outflow in free breast reconstruction if neither the internal mammary nor thoracodorsal veins are sufficient, especially in left-sided reconstruction.  相似文献   

11.
This study evaluates the efficacy of our protocol using intra-arterial infusion of tissue plasminogen activator (TPA) on free flap salvage following venous thrombosis. A retrospective review was conducted of every free flap performed by a single surgeon since the beginning of his practice. Free flap salvage rates were documented following flap exploration, intra-arterial infusion of TPA, and revision of the venous anastomosis, with or without vein grafting. One hundred twenty-two free tissue transfers were performed from July 2003 through April 2006. Twelve anastomotic complications occurred in 11 flaps (1 arterial thrombosis, 11 venous thromboses). One free muscle flap failed due to arterial thrombosis. All venous thromboses were salvaged using the TPA protocol, although one revision thrombosed on postoperative day 1 and required a second venous revision, leading to its ultimate salvage. We believe that intra-arterial TPA is an effective adjunct in the treatment of microsurgical venous thrombosis and may increase salvage rates following anastomotic complications.  相似文献   

12.
Stewart D  Liau J  Vasconez H 《Microsurgery》2009,29(2):115-118
A vena comitant segment harvested from a flap's pedicle can be used as an interpositional vein graft in selected microvascular cases. When a vascular pedicle includes paired venae comitantes, one of these can prove suitable for use as a vein graft while still allowing for venous outflow of the flap. An additional operative site and procedure to harvest a vein graft can be avoided if a vena comitant segment can be used. We present eight cases in which pedicle vena comitant segments were used as interpositional vein grafts. In six cases, vena comitant grafts were used to supercharge or augment venous outflow in transverse rectus abdominis myocutaneous (TRAM) flaps used for breast reconstruction. A vena comitant graft was used to revise the venous anastomosis in one deep inferior epigastric perforator (DIEP) flap. The arterial anastomosis was revised with a vena comitant graft in a gracilis muscle free flap. Our experience demonstrates the viability and utility of using the flap pedicle's vena comitant as a source of vein graft in selected cases.  相似文献   

13.
OBJECTIVE: The objective of this study was to review the outcome of nonoperative treatment for penetrating internal jugular vein (IJ) injuries in a continuous series of prospectively identified, hemodynamically stable patients. METHODS: All penetrating neck injuries assessed from February 1, 2004, to August 31, 2004, were prospectively identified. Patients without an indication for urgent neck exploration underwent diagnostic assessment with multislice helical computed tomographic angiography with or without vascular ultrasonography. All IJ injuries with no other indication for surgical exploration were treated nonoperatively. All patients were discharged home and followed up for a minimum of 1 week to document outcomes. RESULTS: From 51 neck injuries penetrating the platysma, 7 required urgent neck exploration, during which 2 IJ injuries were ligated. Forty-four patients underwent multislice helical computed tomographic angiography. Eight IJ injuries (two gunshot wounds and six stab wounds) with no other indication for neck exploration were identified and managed nonoperatively. One external wound was in zone 1, five were in zone 2, one was in zone 3, and one traversed all three zones. The average length of stay was 4.5 days. At follow-up, ranging from 1 week to 5 months, all patients were asymptomatic, and no patient required delayed operation for IJ injury. CONCLUSIONS: In hemodynamically stable patients with no other indication for exploration, the nonoperative management of penetrating jugular vein injuries should be considered as a safe alternative.  相似文献   

14.
Nahabedian MY  Singh N  Deune EG  Silverman R  Tufaro AP 《Annals of plastic surgery》2004,52(2):148-55; discussion 156-7
The selection of recipient vessels that are suitable for microvascular anastomosis in the head and neck region is one of many components that is essential for successful free tissue transfer. The purpose of this study was to evaluate a set of factors that are related to the recipient artery and vein and to determine how these factors influence flap survival. A retrospective review of 102 patients over a 5-year consecutive period was completed. Indications for microvascular reconstruction included tumor ablation (n = 76), trauma (n = 13), and chronic wounds or facial paralysis (n = 13). The most frequently used recipient artery and vein included the facial, superficial temporal, superior thyroid, carotid, and jugular. Various factors that were related to the recipient vessels were analyzed and included patient age, recipient artery and vein, diabetes mellitus, tobacco use, the timing of reconstruction, the method of anastomosis, previous radiation therapy, creation of an arteriovenous loop, and use of an interposition vein graft. Successful free tissue transfer was obtained in 97 of 102 flaps (95%). Flap failure was the result of venous thrombosis in 4 and arterial thrombosis in 1. Statistical analysis demonstrated that anastomotic failure was associated with an arteriovenous loop (2 of 5, P = 0.03) and tobacco use (3 of 5, P = 0.03). Flap failure was not related to patient age, choice of recipient vessel, diabetes mellitus, previous irradiation, the method of arterial or venous anastomosis, use of an interposition vein graft, or the timing of reconstruction.  相似文献   

15.
To date, the gold standard for performing a microvascular anastomosis has been the penetrating suture with attached needle. During the last two decades, non-penetrating techniques have been introduced, including the Unilink system for end-to-end anastomoses, and the VCS clip-applier system for both end-to-end and end-to-side anastomoses. The aim of this study was to compare the results of different techniques used to create microvascular anastomoses in free-flap reconstructions. Between January 1995 and October 1999, we performed 474 microvascular anastomoses in 216 consecutive free-tissue transfers. The anastomosis techniques included manual sutures (42%), Unilink rings (34%) and VCS clips (24%). Seven combined sutured-clipped anastomoses were excluded from further analysis. The mean anastomotic time when rings were applied was significantly shorter than when using clips (P 0.0001) or sutures (P 0.0001). Venous anastomoses using clips took less time than those using sutures (P 0.05). There were 19 anastomotic failures, all of which lead to early flap failure. Ten flaps were salvaged by early reoperation; nine flaps were lost. Three more flaps were lost as a result of other causes, bringing the flap survival rate down to 94.4%. Early flap failure was caused by failure of the arterial anastomosis in eight cases; all of them were sutured (these represented 5% of all arterial anastomoses with sutures). None of the clipped arterial anastomoses failed. Early flap failure was caused by failure of the venous anastomosis in 11 patients. Three of these anastomoses were sutured (representing 6% of all venous anastomoses with sutures), seven were anastomosed with rings (representing 5% of all venous anastomoses with rings) and one was clipped (representing 2% of all venous anastomoses with clips). Both the VCS clip-applier system and the Unilink system are easy to handle and allow fast microvascular anastomoses without intraluminal penetration. The patency rate of clipped vessels is at least as good as the patency rates of vessels anastomosed using sutures or rings.  相似文献   

16.
Since vein grafting is often required during transplantation of free muscle flaps but is associated with a higher failure rate than those flaps transplanted with primary anastomoses, we sought to compare primary repair with the use of vein grafting in an experimental setting. We transplanted the gracilis muscle to the contralateral side in 98 rats using four different methods of vessel repair. In the Control group (n = 28), both femoral vessels were anastomosed primarily. In Experimental Group 1 (n = 25), the femoral artery was anastomosed with an epigastric vein graft and the femoral vein was anastomosed primarily. In Experimental Group 2 (n = 25), the femoral vein was anastomosed with a femoral vein graft and the femoral artery was anastomosed primarily. In Experimental Group 3 (n = 20), both femoral vessels were anastomosed with vein grafts. The Control and Experimental Groups 1–3 survival rates were 89.3, 76.0, 84.0, and 70.0%, respectively; none of the experimental group survival rates was significantly different from that of the control (P < 0.5). This study demonstrates that the use of size-matched, interpositional vein grafts in the arterial or venous pedicle of the rat gracilis muscle flap during transplantation did not significantly decrease flap survival as compared to primary arterial or venous anastomoses. If the observed failure rate persisted with expansion of the study groups to 60–100 animals each, the failure rate of flaps with vein grafts would be significantly lower and comparable to failure rates reported in some clinical series. The large numbers necessary to significantly show this decrease make this model impractical for further studies © 1997 Wiley-Liss, Inc. MICROSURGERY 17:512–516 1996  相似文献   

17.
Experimental microvascular anastomosis using a glutide copolymer (lactide:glycolide, 80:20) as an external splint was undertaken in 33 rats between the carotid artery and the jugular vein. Both vessels were dissected free over a 1-cm length and cut at the cranial end of the dissected part. The carotid artery was then introduced into a glutide pipe-splint. The arterial wall was turned 180 degrees over the edge of the splint. This reflected artery wall and the glutide were covered by the freed-up jugular vein. One stitch was made around the vein, the artery, and the glutide in a manner similar to binding steel wire over a barrel. Thus, the "one-knot anastomosis" was completed. The patency rate at the anastomosed site was 100%, confirmed by angiography in 30 rats and by direct surgery in three. The time required to produce the anastomosis was between 5 and 7 minutes. Light microscopic observation showed that there was no obstruction by thrombus formation at 1 and 5 weeks after the anastomotic surgery. This technique may be clinically applicable for extracranial-intracranial bypass surgery, reconstruction of venous sinuses, and other vascular procedures.  相似文献   

18.
The effects of the timing and order of clamp removal in microsurgical transplants were studied in rat groin skin flap and rat latissimus dorsi muscle flap models. Forty rats were divided into four groups. In Group 1, the arterial pedicle of the skin flap was anastomosed first, and the clamp was released after the anastomosis was completed. The venous pedicle was then repaired after inflow was restored. In Group 2, the venous pedicle of the skin flap was anastomosed first. The venous clamp was not released until completion of the arterial anastomosis. In Group 3, the arterial pedicle was anastomosed first in the muscle flap. The venous anastomosis was then performed after the arterial clamp was released. In Group 4, the venous pedicle was anastomosed first, and both clamps were released simultaneously. The blood perfusion of the skin flaps was examined after both clamps were released in Groups 1 and 2. The flap survival status was examined 5 days postoperatively for skin flaps and at 3 days for muscle flaps. Skin flaps in an additional six rats were harvested for histology. The results showed that the flap blood flow for Group 1 was statistically significantly higher than for Group 2 flaps in the first 20 min after reperfusion. There was no significant difference of flow between these two groups during the 30 to 90 min after reperfusion. The difference in survival rates for the four groups was not significant. Histology revealed extensive congestion in the flaps from Group 1 after completion anastomoses, but the congestion was significantly decreased at 3 hr following reperfusion. In conclusion, a brief venous stasis during anastomosis, after establishment of arterial inflow, is not detrimental to flap survival. The sequence of anastomosis will not affect outcome for either the cutaneous flap or the muscle flap models. Early flap perfusion was increased when the arterial anastomosis was performed first.  相似文献   

19.
In microsurgical training, the femoral vein is used frequently for a microvenous anastomosis model. But the femoral vein in the rat does not completely simulate the human vein because of its thin wall, fragility, and tendency to collapse. These anatomic characteristics cause some difficulty in carrying out anastomoses in microsurgery training particularly for beginners. The authors propose the external jugular vein of the rat for microsurgical training in microvenous anastomoses. In 10 Wistar rats, the anatomy of the external jugular vein was studied by dissection and histology. Anatomic dissections demonstrate that the external jugular vein has an average diameter of 1.9 mm (range: 1.6 to 2.1 mm) without tendency to collapse. The vein is easily dissected without any accompanying anatomic structure for an average segment of 45 mm, allowing effortless approximator clamp placement. Comparison of its cross section with that of the femoral vein and other previously described models by light microscopy and scanning electron microscopy reveals a larger diameter and much thicker vessel wall with a prominent tunica media and adventitia. Based on the anatomic findings in 20 rats, the external jugular vein was anastomosed with end-to-end standard microsurgical technique using 8-0 (n = 10) and 10-0 (n = 10) nylon sutures. Results indicate a 100 percent patency rate immediately after the anastomosis for the two subgroups and 100 percent and 90 percent patency rates 1 week after the procedure for the 10-0 and 8-0 nylon suture groups, respectively. This model presents some advantages: the vein is easily dissected with the naked eye without using the operating microscope because it is the largest vein among the superficially located veins in the rat, and has a thick vessel wall without tendency to collapse. The operative area allows for training inbilateral microsurgical anastomoses using a single skin incision and is safe from autocannibalization. The model simulates clinical microvenous anastomosis better because of its similarities to human large diameter flap veins.  相似文献   

20.

BACKGROUND:

The microvascular anastomosis remains a technically sensitive and critical determinant of success in free tissue transfer. The microvascular anastomotic coupling device is an elegant, friction-fit ring pin device that is becoming more widely used.

OBJECTIVE:

To systematically review the literature to examine the utility of the microvascular coupler in free tissue transfer.

METHODS:

A comprehensive database search was performed to identify eligible publications. Inclusion criteria were anastomotic coupler utilization and free-tissue transfer. Recorded information from eligible studies included patient age, follow-up, radiation history, number of free-flaps and failure rates, reconstruction subsites, number of coupled venous and arterial anastomoses, coupling time, conversion to sutured anastomosis, coupler size and thrombosis rates.

RESULTS:

Twenty-five studies reporting on 3207 patients were included in the analysis. A total of 3576 free-flaps were performed within the following subsites: 1103 head and neck, 2094 breast, 300 limb or body, and 79 nonspecified. There were only 26 reported flap failures (0.7%). A total of 3497 venous and 342 arterial coupled anastomoses were performed. The primary outcome measure was thrombosis rates, and there were 61 venous (1.7%) and 12 arterial (3.6%) thromboses reported. Mean coupling time was 5 min, and 30 anastomoses (0.8%) were converted to suture.

CONCLUSION:

Flap survival and revision-free application of the microvascular coupler occurred in more than 99% of cases. There is a substantial time savings with coupler use. Venous and arterial thrombosis rates are comparable with the best results achieved by sutured anastomosis and, when used by experienced surgeons, the coupler achieves superior results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号