首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Background: Serum N-terminal probrain natriuretic peptide (NT-proBNP) level is known to be strongly associated with fluid overload, and serves as a guide for fluid management in patients on hemodialysis (HD). This study aimed at investigating the relationship between NT-proBNP level and blood pressure (BP), ultrafiltration/dry weight ratio as well as hemoglobin, and to explore the optimal cutoff point of NT-proBNP level in Chinese patients on HD.

Methods: A total of 306 patients on maintained HD for stage 5 chronic kidney disease (CKD) were included in this prospective study. Their average ultrafiltration/dry weight ratio and BP before dialysis were recorded. The serum NT-proBNP, hemoglobin, serum calcium, and phosphorus were detected. The cutoff value for NT-proBNP level was calculated using receiver operating characteristic (ROC) analysis.

Results: The high NT-proBNP level was associated with high BP and ultrafiltration/dry weight ratio, and low hemoglobin level. The optimal cutoff point of NT-proBNP level for patients on maintained HD was 5666?pg/mL, with a sensitivity of 78.5%, specificity of 43.9%, and area under the curve (AUC) of 0.703 (<0.001).

Conclusions: NT-proBNP level ≤5666?pg/mL was recommended to achieve the target BP, hemoglobin level, and ultrafiltration/dry weight ratio in patients on maintained HD with an ejection fraction (EF) >50%.  相似文献   

2.
Purpose: This study aimed to use proteomics methods to investigate the changes in serum protein levels after high- and low-flux hemodialysis (HD).

Methods: Before and after HD, serum samples were obtained from two selected patients who were treated with a Polyflux 140?H high-flux dialyzer and a Polyflux 14?L low-flux dialyzer during two continuous therapy sessions. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) was performed to identify the proteins.

Results: A total of 212 and 203 serum proteins were identified after high-flux and low-flux HD, respectively. After high-flux HD, 21 proteins increased, and 132 proteins decreased. After low-flux HD, 87 proteins increased, and 45 proteins decreased. High-flux HD led to a significantly greater reduction in protein levels than low-flux HD (0.73?±?0.13 vs. 0.84?±?0.18, p?=?.00). Among the increased and decreased proteins, the isoelectric point (pI) values mainly ranged from 5 to 7, and the molecular weights (Mws) were mostly smaller than 30?kDa. The serum proteins showed no difference in pI or Mw for high- and low-flux HD. Gene ontology (GO) analysis showed that the detected proteins were related to immune system processes and complement activation.

Conclusions: Serum protein levels differentially changed after high- and low-flux HD. Long-term effects should be observed in future studies.  相似文献   

3.
Introduction: Left ventricular hypertrophy (LVH) is one of the most common cardiac abnormalities in patients with end stage renal disease (ESRD). Hypertension, diabetes, increased body mass index, gender, age, anemia, and hyperparathyroidism have been described as risk factors for LVH in patients on dialysis. However, there may be other risk factors which have not been described yet. Recent studies show that renalase is associated with cardiovascular events. The aim of this study was to reveal the relation between renalase, LVH in patients under hemodialysis (HD) treatment.

Methods: The study included 50?HD patients and 35 healthy controls. Serum renalase levels and left ventricle mass index (LVMI) were measured in all participants and the relation between these variables was examined.

Findings: LVMI was positively correlated with dialysis vintage and C-reactive protein (CRP) (r?=?0.387, p?=?0.005 and r?=?0.597, p?r?=??0.324, p?=?0.022 and r?=??0.499, p?r?=?0.263, p?=?0.065). Serum renalase levels were significantly higher in HD patients (212?±?127?ng/mL) compared to controls (116?±?67?ng/mL) (p?r?=?0.677, p?r?=?0.625, p?Discussion: In our study, LVMI was correlated with dialysis vintage, residual diuresis, CRP, and hemoglobin. LVMI tends to correlate with renalase and this correlation may be significant in studies with more patient numbers. The main parameters affecting renalase levels are dialysis vintage and serum creatinine.  相似文献   

4.
Background: Cytokines are essential mediators of immune response. Chronic renal failure patients suffer from chronic inflammation that results from factors such as impaired renal function, accumulation of uremic toxins and bio incompatibility of dialyzer membranes. These patients are also at increased risk of cardiovascular diseases. We have evaluated cytokines, adipocytokines and inflammatory markers in patients with chronic renal failure undergoing hemodialysis (HD) and continuous ambulatory peritoneal dialysis (CAPD).

Material and methods: We have determined serum tumor necrosis factor-α (TNF-α), interleukin-6 (IL-6), high-sensitivity C-reactive protein (hsCRP), leptin and ghrelin levels of chronic renal failure patients treated with either HD (n?=?20) or CAPD (n?=?20). TNF-α, IL-6, ghrelin and leptin measurements were performed by commercially available kits based on enzyme-linked immunosorbent assay (ELISA) method. hsCRP levels were determined by turbidimetric methods.

Results: Serum TNF-α and IL-6 levels of patients on HD were significantly higher than those of the ones on CAPD (p?<?0.05). Ghrelin, leptin and hsCRP concentrations were similar in both groups.

Conclusions: We can conclude that cytokine production is more obvious in HD process.  相似文献   

5.
Background: This study investigated the therapeutic effect of intensive phosphorus-lowering therapy on intact-parathyroid hormone (iPTH) levels in hemodialysis patients.

Methods: Ninety-five hemodialysis patients with serum phosphorus ≥1.78?mmol/L and iPTH ≥300?pg/dL were apportioned to either the treatment or control group (n?=?43 and 52, respectively) based on patient commitment to treatment. The treatment group was given phosphorus-lowering therapies with phosphate binders (lanthanum, sevelamer or/and calcium reagent) combined with dietary phosphate restriction and intensified hemodialysis. The control individuals were given low doses of calcium agents, if serum calcium was <2.54?mmol/L. Percent changes in serum phosphorus and iPTH levels were compared between the two groups. In addition, based on the time required to achieve >20% decrease in serum phosphorus, the patients in the treatment group were further stratified as rapid responders (≤2?months; 27 patients) or slow responders (>2?months; 16 patients) and percent changes in iPTH were compared.

Results: Serum phosphorus and iPTH levels decreased from baseline in the treatment group (?24.08?±?1.93% and ?9.92?±?3.70%, respectively) but increased in the control group (22.00?±?3.63% and 104.21?±?23.89%; both p?p?Conclusions: For these patients on maintenance hemodialysis, intensive treatment of hyperphosphatemia was associated with a decrease in iPTH levels, especially for those who had achieved substantial reduction in serum phosphorus within 2?months.  相似文献   

6.
An increase of brain natriuretic peptide (BNP) levels is commonly observed in patients on dialysis. Increased circulating levels of BNP are related to future cardiac events and associated with shorter survival in patients on chronic hemodialysis (HD). During the first 1 or 2 years on dialysis, patients on peritoneal dialysis (PD) have been shown to have an improvement in left ventricular hypertrophy, blood pressure, and volume status. This study compares BNP levels and cardiac status of PD and HD patients without cardiovascular disease and on dialysis for less than 36 months. The correlation between plasma BNP concentration and findings of echocardiography before HD scans were examined and compared with findings of PD. Twenty-two HD patients (15 men, 7 women; mean age, 52.5 ± 13.9 years) and 19 PD patients (10 men, 9 women; mean age, 47.6 ± 11.3 years) were studied. There were no significant differences between HD and PD patients with regard to age, gender, duration of dialysis, left ventricular mass, left ventricular mass index (p > 0.05). Plasma BNP levels were markedly greater in HD patients (467.8 ± 466.5 pg/mL) than those of PD patients (143.1 ± 165.2 pg/mL). Urine output was significantly higher in PD patients compared with HD patients (p < 0.05). A positive correlation between systolic blood pressure, diastolic blood pressure, and plasma BNP in HD patients (r: 0.653, p: 0.001; r: 0.493, p: 0.023, respectively) was detected. Additional studies are needed to investigate whether lower BNP level in PD patients is an advantage.  相似文献   

7.
《Renal failure》2013,35(3):398-407
Abstract

Background: This was controversial whether vitamin E-coated dialyzer therapy was beneficial for the complications associated with hemodialysis. Therefore, we performed this systematic review to evaluate the effects of vitamin E-coated dialyzer. Methods: Related trials were searched from multiple electronic databases. We conducted meta-analysis to assess changes in the predefined outcomes using RevMan 5.3 software. Results: Meta-analysis showed vitamin E-coated dialyzer therapy could decrease erythropoietin (EPO) resistance index (SMD, ?0.24; 95% CI, ?0.47 to ?0.01; p?=?0.04). However, pooled-analysis showed vitamin E-coated dialyzer therapy could not decrease weekly EPO dose (SMD, ?0.11; 95% CI, ?0.32 to 0.09; p?=?0.28) and intima–media thickness (IMT) of the carotid artery (MD, ?0.09; 95% CI, ?0.2 to 0.01; p?=?0.09), and vitamin E-coated dialyzer therapy did not improve the serum hemoglobin (MD, ?0.03; 95% CI, ?0.18 to 0.13; p?=?0.74), albumin levels (SMD, ?0.64; 95% CI, ?1.62 to 0.34; p?=?0.2), in addition, there was no significant difference in serum cholesterol (SMD, ?0.07; 95% CI, ?0.45 to 0.31; p?=?0.71), triglycerides (MD, ?2.77; 95% CI, ?32.42 to 26.87; p?=?0.85), high density lipoprotein (HDL) (SMD, 0.24; 95% CI, ?0.14 to 0.62; p?=?0.22) and low density lipoprotein (LDL) (SMD, 0.00; 95% CI, ?0.38 to 0.37; p?=?0.98) levels. Conclusions: Vitamin E-coated dialyzer may reduce the EPO resistance, but there is no conclusive evidence that vitamin E-coated dialyzer can improve the renal anemia, malnutrition, dyslipidemia and atherosclerosis status in hemodialysis (HD) patients. However, high-quality trials with hard clinical endpoints are required to fully elucidate the clinical value of vitamin E-coated dialyzer therapy.  相似文献   

8.
BACKGROUND: Metabolic acidosis contributes to renal osteodystrophy and together with hyperphosphatemia, hypocalcemia and altered vitamin D metabolism may result in increased levels of intact parathyroid hormone (iPTH) and metastatic calcifications. However, the impact of the correction of metabolic acidosis on iPTH levels and calcium-phosphate metabolism is still controversial. STUDY DESIGN: The effects of the correction of metabolic acidosis on serum concentrations of iPTH, calcium (Ca), phosphate (PO(4)) and alkaline phosphatase were prospectively studied. Twelve uremic patients on maintenance hemodialysis (HD) for 49 months (median; range 6-243 months) with serum bicarbonate levels < or =20 mmol/l were studied before and after 3 months of oral sodium bicarbonate supplementation. Predialysis serum bicarbonate, arterial pH, ionized calcium, plasma sodium, plasma potassium, serum creatinine, hemoglobin, K(t)/V, postdialysis body weight, predialysis systolic and diastolic blood pressure were also evaluated before and after correction. RESULTS: Serum bicarbonate levels and arterial pH increased respectively from 19.3 +/- 0.6 to 24.4 +/- 1.2 mmol/l (p < 0.0001) and 7.34 +/- 0.03 to 7.40 +/- 0.02 (p < 0.001). iPTH levels decreased significantly from 399 +/- 475 to 305 +/- 353 pg/ml (p = 0.026). No changes in total serum Ca, plasma PO(4), serum akaline phosphatase, K(t)/V, serum creatinine, hemoglobin, body weight, predialysis systolic and diastolic blood pressures were observed. iCa decreased significantly. CONCLUSIONS: Our study demonstrates that the correction of metabolic acidosis in chronic HD patients reduces iPTH concentrations in HD patients with secondary hyperparathyroidism possibly by a direct effect on iPTH secretion.  相似文献   

9.
Highly permeable dialysis membranes with better design filters have contributed to improved solute removal and dialysis efficacy. However, solute membrane permeability needs to be well controlled to avoid increased loss of albumin that is considered to be detrimental for dialysis patients. A novel high‐flux dialyzer type (FX CorDiax; Fresenius Medical Care) incorporating an advanced polysulfone membrane modified with nano‐controlled spinning technology to enhance the elimination of a broader spectrum of uremic toxins has been released. The aim of this study was to compare in the clinical setting two dialyzer types having the same surface area, the current (FX dialyzer) and the new dialyzer generation (FX CorDiax), with respect to solute removal capacity over a broad spectrum of markers, including assessment of albumin loss based on a direct dialysis quantification method. We performed a crossover study following an A1‐B‐A2 design involving 10 patients. Phase A1 was 1 week of thrice‐weekly bicarbonate hemodialysis with the FX dialyzer, 4 h per treatment; phase B was performed with a similar treatment regimen but with a new FX CorDiax dialyzer and finally the phase A2 was repeated with FX dialyzer as the former phase. Solute removal markers of interest were assessed from blood samples taken before and after treatment and from total spent dialysate collection (direct dialysis quantification) permitting a mass transfer calculation (mg/session into total spent dialysate/ultrafiltrate). On the blood side, there were no significant differences in the solute percent reduction between FX CorDiax 80 and FX 80. On the dialysate side, no difference was observed regarding eliminated mass of different solutes including β2‐microglobulin (143.1 ± 33.6 vs. 138.3 ± 41.9 mg, P = 0.8), while the solute mass removal of total protein (1.65 ± 0.51 vs. 2.14 ± 0.75 g, P = 0.04), and albumin (0.41 ± 0.21 vs. 1.22 ± 0.51 g, P < 0.001) were significantly less for FX CorDiax 80 compared to the FX 80 dialyzer. The results of this cross‐over study indicate that the new FX CorDiax dialyzer has highly effective removal of middle molecules, without any concomitant increase in total protein and albumin loss. The clinical relevance and potential benefit of this finding needs to be determined.  相似文献   

10.
11.
《Renal failure》2013,35(9):1204-1209
Abstract

This cross-sectional study aims to identify the potential risk factors of left ventricular hypertrophy (LVH) in hemodialysis (HD) patients. Echocardiography, anthropometric measurements and biochemical analyses were performed for 112 HD patients. In univariate analysis, body mass index, systolic blood pressure, diastolic blood pressure, glycosylated hemoglobin, glycated albumin, high sensitivity C-reactive protein (hs-CRP), cardiac troponin T (cTnT), amino-terminal pro-B-natriuretic peptide (NT-proBNP) and carotid artery intima-media thickness were positively correlated with left ventricular mass index (LVMI); pre-albumin, serum creatinine, left ventricular ejection fraction (LVEF) and fractional shortening were negatively correlated with LVMI. Linear regression analysis showed systolic blood pressure, NT-proBNP and LVEF were independently associated with LVMI. According to a binary logistic regression model, higher systolic blood pressure, NT-proBNP and hs-CRP levels showed independent correlation with LVH. Receiver operator characteristic curves analysis showed the associations between NT-proBNP and LVH more closely than hs-CRP and cTnT. The area under the curve for NT-proBNP, hs-CRP and cTnT was 0.762 (95% CI: 0.660–0.864, p?<?0.001), 0.734 (95% CI: 0.624–0.844, p?<?0.001) and 0.677 (95% CI: 0.563–0.790, p?=?0.004), respectively. These data support the main conclusions: hypertension, fluid overload and micro inflammation are associated with LVH in maintenance HD patients. It demonstrates traditional and nontraditional risk factors all play important roles in the development of LVH.  相似文献   

12.
《Renal failure》2013,35(9):1114-1117
The aim of this study was to determine blood lead level (BLL) in hemodialysis (HD) patients and their relation with high-sensitivity C-reactive protein (hsCRP) and albumin which are inflammatory and nutritional biomarkers, respectively, and clinical complications. A total of 93 patients, who were dialyzed at least for 3 months, were included in the study. Blood samples were collected before HD and BLL was measured and categorized as three equal groups: low normal (BLL < 8 μg/dL), middle normal (BLL = 8–10.6 μg/dL), and high normal (BLL > 10.6 μg/dL). All patients had normal BLL, 9.7 ± 3.4 g/dL. Patients with abnormal hsCRP level (>3 mg/L) had higher BLL than other patients (16.4 ± 0.8 vs. 11.5 ± 2.7 mg/L, p = 0.003). Patients with BLL > 10.6 μg/dL had significantly lower hemoglobin, ferritin, iron, and albumin levels and higher hsCRP and intact parathyroid hormone (iPTH) levels than the patients with BLL < 8 μg/dL. In addition, BLL revealed a significant positive correlation with duration of dialysis. We concluded that BLL associated to inflammation, malnutritional status, iron-deficiency condition, and high iPTH level in HD patients.  相似文献   

13.
In patients with enhanced risk for bleeding, heparin‐free hemodialysis (HD) with conventional dialyzers is routinely used. To explore the potential benefit of using heparin‐coated dialyzers, we used a reference CT‐scanning technique and registered different clotting parameters to quantify coagulation with heparin‐coated versus non‐coated dialyzers. Six HD patients with thrombocytopenia were dialyzed 240 min in a randomized crossover study with Evodial 1.3 or FX600 Cordiax, each without anticoagulation. Blood samples were taken from the vascular access predialysis, and from the dialyzer inlet and outlet at 5 and 240 min after dialysis start. Predialysis blood samples were analyzed for hemoglobin, hematocrit, thrombocytes, fibrinogen, and activated partial thromboplastin time. On dialyzer inlet and outlet blood samples, a viscoelastic measurement of blood coagulation was performed using a Sonoclot analyzer. After dialysis, dialyzers were visually scored, subsequently dried for 24 h, weighed, and scanned with micro‐CT at a resolution of 25 µm. After image reconstruction, the open, non‐coagulated fibers were counted in a representative cross‐section at the dialyzer outlet. No sessions were terminated prematurely for circuit clotting. Heparin‐coated dialyzers had more patent fibers on micro‐CT versus non‐coated dialyzers and also had a better score of subjective visual assessment of fiber clotting. There was no difference in subjective assessment of clotting at the venous drip chamber. With both dialyzers, all ACT values remained in the normal range, and were lower at the dialyzer outlet versus inlet. In conclusion, dialysis with a heparin‐coated versus non heparin‐coated membrane results in substantially less coagulated fibers during 4 h hemodialysis without systemic anticoagulation. Eventual leaching of heparin, immobilized on the fiber membrane, does not result in measurable systemic anticoagulation.  相似文献   

14.
Background. Left ventricular hypertrophy (LVH) is common in dialysis patients, and an independent predictor of mortality. While recent studies have shown no differences in mortality between the two most common dialysis modalities, hemodialysis (HD) and peritoneal dialysis (PD), their impact on LVH is controversial. We thus performed cardiac ultrasound studies in prevalent dialysis patients receiving either HD or PD and compared LVH. Methods. We included 48 HD and 62 PD patients receiving treatment for at least three months in our dialysis center. All patients underwent echocardiographic examination and blood pressure measurements immediately following therapy. Volume status was assessed by bioelectrical impedance analysis. Results. There was no baseline difference in demographics or comorbidities between HD and PD patients. As expected, extracellular water (ECW) in post-HD patients was significantly lower than that in pre-HD and PD patients, while cardiac output (CO) and systolic blood pressure (SBP) were higher in pre-HD than that in post-HD or PD patients. There was no significant difference in CO or SBP between post-HD and PD patients. Left ventricular mass index (LVMI) was markedly higher in HD patients as compared to PD patients. Thus, the prevalence of LVH according to the Framingham criteria was 68.8% in HD patients and 45.2% in PD patients. Subgroup analysis showed similar results in the patients who had been on single-modality dialysis for at least two years and in the anuric patients. Finally, in a linear regression model (r2 = 0.364, p < 0.001), SBP, treatment modality (to be in HD), and ECW were all independent predictors of LVMI. Conclusions. In a cross-sectional analysis of prevalent Chinese patients, we found a higher LVMI and a higher prevalence of LVH in HD than in PD patients. As LVMI was associated with high blood pressure and volume overload, we suggest that in these patients, PD may preserve more physiological hemodynamics even during long-term therapy.  相似文献   

15.
Background. To evaluate the benefits of dialyzer reuse for hemodialysis (HD) patients, including the cost of HD treatment and patient's survival, a comparison was made regarding the standard practice of single-use dialysis. Methods. From January 1, 2005, to December 31, 2005, a total of 128,232 successive HD treatments in 822 patients in Chang Gung Memorial Hospital-Kaohsiung Medical Center were included in this study. Results. Approximately 54.25% (446/822) of patients reused dialyzers. The average times of dialyzer reuse was 2.54. The annual hollow fiber cost is reduced by $241,054.08 U.S. dollars (NT $7,834,257.60). The annual cost of hollow fiber was reduced by $540.48 U.S. dollars (NT $17,565.60) in one patient with dialyzer reuse. The mortality rates in dialyzer reuse and single use groups were 3.1% and 10.9% within one year (p < 0.0001). Multiple logistic regressions showed that single use compared with reuse was associated with higher mortality after adjusting co-morbid conditions including age, diabetes mellitus, etc. Conclusions. We concluded that the benefits of dialyzer reuse included safety in our center and reduction in cost during a 12-month period. Dialyzer reuse may be a safe alternative.  相似文献   

16.
IntroductionCalciphylaxis is a rare but potentially fatal disease commonly occurred in dialysis patients. Despite some previous studies on risk factors for calciphylaxis, there is still a lack of data from Chinese population.MethodsThe retrospective matched case–control study about calciphylaxis was performed in Zhongda Hospital affiliated to Southeast University. The case group involved 20 hemodialysis patients who were newly diagnosed with calciphylaxis from October 2017 to December 2018. The 40 noncalciphylaxis patients undergoing dialysis with the same age and duration of dialysis were randomly selected as controls.ResultsMost of calciphylaxis patients were male and elderly, while overweight people were more susceptible to the disease. Although incidence of secondary hyperparathyroidism was higher in calciphylaxis patients, the differences in duration of elevated serum intact parathyroid hormone (iPTH) and its highest value did not reach statistical significance compared with controls. No significant difference in warfarin therapy was discernible between two groups. The univariate regression analysis indicated that male, score of use of activated vitamin D and its analogues, corrected serum calcium level, serum phosphate, Ca × P product, iPTH, albumin, and alkaline phosphatase (ALP) level were significantly associated with calciphylaxis. Elevated levels of serum phosphate (OR 4.584, p = 0.027) and ALP (OR 1.179, p = 0.036), decreased level of serum albumin (OR 1.330, p = 0.013) were independent risk factors after multivariate analysis.ConclusionThis is the first report of risk factors associated with calciphylaxis in China. Increased levels of serum phosphate and ALP, decreased level of serum albumin were vital high-risk factors for calciphylaxis in Chinese hemodialysis population.  相似文献   

17.
《Renal failure》2013,35(5):660-666
Background: Our study aimed to investigate the factors associated with elevated plasma FGF23 (cFGF23) levels in maintenance hemodialysis (MHD) patients and to determine whether plasma FGF23 level is related to aortic artery calcification (AAC). Methods: This study included 120 MHD patients and 20 controls. The FGF23 level was measured using a C-terminal assay and AAC was detected by a lateral lumbar X-ray plain. Results: Plasma FGF23 levels were significantly higher among dialysis patients compared to controls: FGF23 level of 27691.42 ± 55646.41 RU/mL in MHD patients versus 49.89 ± 23.94 RU/mL in health people. Significant correlations were observed between FGF23 levels and vintage, intact parathyroid hormone (iPTH), serum phosphate, total calcium, 25(OH)D, urea nitrogen (BUN), and serum creatinine (SCR). Stepwise multiple regression analysis showed that the independent parameters associated with FGF23 level were serum phosphate, total calcium, parathyroid hormone (PTH), SCR, and prealbumin. There were 73 patients (60.83%) with visible calcification in the abdominal aorta. Bivariate analysis showed that AAC score correlated with FGF23, phosphate, total calcium, vintage, age, and diastolic blood pressure. Forward logistic analysis showed that the independent parameters associated with AAC were age, total protein, and Lg FGF23. Conclusion: Plasma FGF23 level is significant increased in hemodialysis patients and is independently associated with AAC.  相似文献   

18.
目的 对比血液透析及腹膜透析患者钙磷及甲状旁腺激素水平控制情况并分析相关影响因素.方法 单中心横断面观察研究纳入2013年3月至2015年3月在我院接受规律维持性透析治疗3个月以上、临床状况稳定的患者.收集患者临床资料,分析比较不同透析方式的患者血钙、血磷、全段甲状旁腺激素(intact parathyroid hor...  相似文献   

19.
We were encouraged to investigate the reasons for large amounts of foam observed in bloodlines during hemodialysis (HD). Foam was visible in the venous air trap within the Artis Gambro dialysis device. Estimates of the extent of foam were graded (0—no foam, 10—extensive foam) by two persons that were blind to the type of dialyzer used. Thirty‐seven patients were involved in the dialysis procedures. Consecutive dialyses were graded using dialyzers from Fresenius Medical Care (CorDiax dialyzers that were used for high flux HD—FX80 and FX100, and for hemodiafiltration—FX1000). The extracorporeal circuit was primed automatically by dialysate using Gambro Artis software 8.15 006 (Gambro, Dasco, Medolla Italy, Baxter, Chicago, IL, USA). The priming volume recommended by the manufacturer was 1100 mL, whereas our center uses 1500 mL. Extensive amounts of blood foam were visual in the air traps. Although the manufacturer recommended extension of priming volume up to 3000 mL, this did not eliminate the foam. Microbubble measurement during HD revealed the air to derive from the dialyzers. When changing to PF210H dialyzers (Baxter) and using a priming volume of 1500 mL, the foam was significantly less (P < 0.01). The extent of foam correlated with the size of the FX‐dialyzer surface (P = 0.002). The auto‐priming program was updated to version 8.21 by the manufacturer and the extent of foam in the air trap using FX dialyzers was now reduced and there was no longer a difference between FX and PF dialyzers, although less foam was still visible in the venous air trap during several dialyses. In conclusion, this study urgently calls attention to blood foam development in the venous air trap when using Artis devices and priming software 8.15 in combination with Fresenius dialyzers. Updated auto‐priming software (version 8.21) of Artis should be requested to reduce the extent of foam for the Fresenius dialyzers. Other interactions may also be present. We recommend further studies to clarify these problems. Meanwhile caution is warranted for the combined use of dialysis devices and dialyzers with incompatible automatic priming.  相似文献   

20.
The appropriate dialysate calcium concentration (D[Ca]) for hemodialysis (HD) therapy has not yet reached a consensus. We have conducted a prospective control study for five years on the effects of different D[Ca] on serum intact parathyroid hormone (iPTH) levels. Patients were divided into three groups receiving different D[Ca] therapies: the low-Ca (D[Ca]?=?2.5 mEq/L; N?=?96), mid-Ca (D[Ca]?=?3.0 mEq/L; N?=?121), and high-Ca (D[Ca]?=?3.5 mEq/L; N?=?82) groups. After five years' study, only 41 patients in the low-Ca group, 34 in the mid-Ca group, and 32 in the high-Ca group completed the study. The results demonstrated that serum corrected calcium concentrations were significantly lower in the low-Ca group compared with other groups in years 3 and 4, although the products of corrected calcium time phosphate did not show difference between each group.Δserum alkaline phosphatase (ΔAlk-p) to baseline levels increased significantly after the fourth year in all three groups (p < 0.05). Serum Δ iPTH only increased significantly after the fourth year in the low-Ca group (p < 0.05) but not in the other groups. There were no significant differences in the extent of ΔAlk-p and ΔiPTH between the groups. Cox proportional methods also showed no difference in cumulative survival between the groups. In conclusion, our results demonstrate that compared with the other two groups of D[Ca], long-term use of D[Ca] of 2.5 mEq/L was associated with relatively lower serum calcium concentration. Perhaps this was related to a greater extent of iPTH concentration elevation after five years.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号