首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Mammographic image quality, contrast and dose for a variable tube potential (kVp) technique protocol for film-screen mammography have been investigated. In this protocol, the tube potential is increased for larger breast thicknesses. Comparisons were made with fixed kVp protocols, in which the tube potential is kept constant and the breast thickness compensated for by prolonging the exposure ("fixed kVp" protocol). All measurements were performed on a mammography unit with a molybdenum target and filter. Image quality was quantified by image contrast, image detail detection and the minimum detectable dimension of low contrast objects. It was demonstrated that for a compressed breast thickness of less than about 40 mm, varying the tube potential had a negligible effect upon dose but a significant effect upon image quality. For a compressed breast thickness greater than about 60 mm, the effect of the tube potential upon image quality was much reduced; however, the effect upon dose was significantly greater. The variable kVp protocol takes advantage of this feature to yield a significantly lower dose for thicker breasts with a small reduction in image quality, often only within experimental uncertainty. For an exposure under automatic exposure control, increasing the tube potential from 26 kVp to 30 kVp for a breast of a reference tissue composition (50% adipose and 50% glandular) with a compressed thickness of 60 mm reduced the mean glandular dose from 6 mGy to 3.9 mGy (-35%), but increased the minimum detectable dimension of a low contrast mass from 0.8 (+/- 0.1) mm to 1.1 (+/- 0.1) mm. Adopting a variable kVp protocol led to a median patient mean glandular dose per film of 2.7 mGy, nearly independent of compressed breast thickness. In our survey, the mean age of women presenting for mammography is younger and the mean compressed breast thickness is less than reported from screening centres. This suggests that there will be a higher proportion of denser, glandular tissue in the breasts incorporated within this survey than for surveys from screening centres. The clinical use of the variable kVp protocol allows the extraction from patient data of separate changes in breast composition which are due to patient age and breast thickness. It is concluded that the reference breast tissue composition is not an accurate representation of the women presenting at this centre.  相似文献   

2.
Extended exposure times in magnification mammography are a result of the reduced X-ray tube currents required for a small focal spot. The consequences of this are the potential for reduced image quality through motion blur during exposure as well as the onset of film reciprocity law failure. Previous investigators have suggested increasing the X-ray tube potential as a practical mechanism for reducing exposure times in magnification mammography and have demonstrated negligible image quality degradation at least up to 32 kVp. This paper describes a film-screen magnification mammography study that expands upon this previous work to investigate the magnitude of the reduction of breast mean glandular dose and exposure time and the changes in subjective image quality (visibility of low contrast details in an RMI 152 phantom) with increases in tube potential between 28 kVp and 35 kVp. Measures of changes in the radiographic contrast and in the scatter-to-primary ratio (SPR) in magnification geometry as a function of tube potential were also obtained. Evidence for reciprocity law failure was also assessed. For a constant film optical density, increasing the X-ray tube potential from 28 kVp to 35 kVp reduced the mean glandular dose from 3.9 mGy to 2.7 mGy and reduced the exposure time from 3.2 s to 1.0 s. Over this range, the detection rate of fibrils and microcalcification-mimicking specks did not vary with tube potential at the 0.05 level of significance. It was found that only the low contrast mass detail detection rate at 35 kVp was significantly less than that at 28 kVp. The measured radiographic contrast decreased with tube potential and the SPR increased with tube potential. However, both changes were weak, and linear regressions determined that the 95% confidence intervals of the slopes relating both contrast and SPR with tube potential encompassed zero. It is concluded that magnification mammography performed at 34 kVp yields significant reductions in exposure time and mean glandular dose, with a detail detection capability similar to that at 28 kVp.  相似文献   

3.
This paper outlines how objective measurements of both image quality, in terms of signal-to-noise ratio, and effective dose may be used as tools to find the optimum kVp range for a digital chest radiography system. Measurements were made with Thoravision, an amorphous selenium-based digital chest X-ray system. The entrance surface dose and the effective dose to an anthropomorphic chest phantom were determined demonstrating how effective dose is related to beam quality. The image quality was measured using detective quantum efficiency, threshold contrast and a radiologist preference trial involving 100 patients. The results show that, despite the fact that the entrance surface dose decreases as the kVp increases, the effective dose, a better measure of the risk, reaches a minimum value between 90 and 110 kVp; however, the image quality decreases as the kVp increases. In this study the optimum kVp for chest radiography, using a selenium-based radiography system, is in the range 90–110 kVp. This is contrary to the 120- to 150-kVp range that is commonly used. Also, this study shows how objective measurements can be used to optimise radiographic technique without prolonged patient trials. Received: 4 November 1999 Revised: 10 May 2000 Accepted: 11 May 2000  相似文献   

4.
For assessment of the effect of varying the peak kilovoltage (kVp), the adaptive statistical iterative reconstruction technique (ASiR), and automatic dose modulation on radiation dose and image noise in a human cadaver, a cadaver torso underwent CT scanning at 80, 100, 120 and 140 kVp, each at ASiR settings of 0, 30 and 50 %, and noise indices (NIs) of 5.5, 11 and 22. The volume CT dose index (CTDIvol), image noise, and attenuation values of liver and fat were analyzed for 20 data sets. Size-specific dose estimates (SSDEs) and liver-to-fat contrast-to-noise ratios (CNRs) were calculated. Values for different combinations of kVp, ASiR, and NI were compared. The CTDIvol varied by a power of 2 with kVp values between 80 and 140 without ASiR. Increasing ASiR levels allowed a larger decrease in CTDIvol and SSDE at higher kVp than at lower kVp while image noise was held constant. In addition, CTDIvol and SSDE decreased with increasing NI at each kVp, but the decrease was greater at higher kVp than at lower kVp. Image noise increased with decreasing kVp despite a fixed NI; however, this noise could be offset with the use of ASiR. The CT number of the liver remained unchanged whereas that of fat decreased as the kVp decreased. Image noise and dose vary in a complicated manner when the kVp, ASiR, and NI are varied in a human cadaver. Optimization of CT protocols will require balancing of the effects of each of these parameters to maximize image quality while minimizing dose.  相似文献   

5.
Many departments still do not use recommended radiographic parameters to X-ray neonates. Direct, accurate dose measurements of individual examinations may assist a department in justifying technique modifications that provide a substantial dose reduction without a significant loss of image quality. The aim of this study was to investigate dose reduction techniques for neonates in the intensive care unit. Alterations in beam energy (kVp and filtration) and collimation were investigated using specially designed phantoms mimicking a 700 g and 2000 g neonate, and ultrasensitive LiF:Mg,Cu,P thermoluminescence dosimeters (TLDs). Differences in entrance surface dose (ESD) and dose at depth (3 cm or 5 cm) were compared for two, overlapping fields centred individually on the chest and abdomen (Technique 1) and one large chest-abdomen field (Technique 2 or babygram). The large phantom was irradiated at 54 kVp, 60 kVp and 70 kVp without additional filtration and at 66 kVp and 70 kVp with a rare-earth hafnium filter. Focus-film distance (FFD) and mAs were adjusted to maintain optical density (OD) on each radiograph. The baseline dose at 54 kVp and 100 cm FFD was (46+/-2) micro Gy. Increasing the tube potential from 54 kVp to 70 kVp without additional filtration reduced the ESD by 27%. However, the addition of a 0.05 mm hafnium filter at 66 kVp further reduced the radiation dose by 13%, to produce an ESD of (28+/-2) micro Gy. All contrast details were observable at 66 kVp with hafnium filtration. Technique 1 may lead to an increase in effective dose due to field overlap, which diverges at depth, and increased scatter at the periphery of the fields.  相似文献   

6.
The purpose of this work was to present body size and tube voltage-dependent equations for optimal selection of image acquisition parameters in guiding clinical X-ray imaging. The dose output of X-ray tubes was expressed as a function of the image acquisition parameters of tube voltage (kVp), tube current–exposure time product (mAs), and body size (d). Dose power (n) to kVp was determined to be a linear function of body size in an earlier phantom study. Tube voltage-dependent attenuation coefficients of water were used to determine the kVp effect on the depth dose of X-rays from the body’s entrance surface. The new expression for the dose output of X-ray tubes in patients was then employed for image quality and radiation dose optimization, assuming that image quality is a logistic function of the radiation dose to patients. For constant kVp, the percentage of mAs increase for a 1-cm increase in body size d is dependent on the kVp applied. For constant mAs, the percentage of kVp increase for a 1-cm increase in body size is dependent on both body size d and the kVp applied. For constant body size, the percentage of kVp increase should be a fraction of the percentage of decrease in the mAs, where the fraction is dependent on the body size. The improved body size and tube voltage-dependent governing equations for variations in X-ray imaging parameters should be more accurate in guiding optimal selection of the kVp and mAs image acquisition parameters in medical X-ray imaging.  相似文献   

7.
The purpose of this study was to evaluate the achievable organ dose savings in low-dose multislice computed tomography (MSCT) of the heart using different tube voltages (80 kVp, 100 kVp, 120 kVp) and compare it with calculated values. A female Alderson-Rando phantom was equipped with thermoluminescent dosimeters (TLDs) in five different positions to assess the mean doses within representative organs (thyroid gland, thymus, oesophagus, pancreas, liver). Radiation exposure was performed on a 16-row MSCT scanner with six different routine scan protocols: a 120-kV and a 100-kV CT angiography (CTA) protocol with the same collimation, two 120-kV Ca-scoring (CS) protocols with different collimations and two 80-kV CS protocols with the same collimation as the 120-kV CS protocols. Each scan protocol was repeated five times. The measured dose values for the organs were compared with the values calculated by a commercially available computer program. Directly irradiated organs, such as the esophagus, received doses of 34.7 mSv (CTA 16×0.75 120 kVp), 21.9 mSv (CTA 16×0.75 100 kVp) and 4.96 mSv (CS score 12×1.5 80 kVp), the thyroid as an organ receiving only scattered radiation collected organ doses of 2.98 mSv (CTA 16×0.75 120 kVp), 1.97 mSv (CTA 16×0.75 100 kVp) and 0.58 mSv (CS score 12×1.5 80 kVp). The measured relative organ dose reductions from standard to low-kV protocols ranged from 30.9% to 55.9% and were statistically significant (P<0.05). The comparison with the calculated organ doses showed that the calculation program can predict the relative dose reduction of cardiac low photon-energy protocols precisely.  相似文献   

8.
降低儿童16层螺旋CT检查辐射剂量的研究   总被引:5,自引:1,他引:4       下载免费PDF全文
目的论证CT扫描参数kVp和mAs与剂量和图像噪声的关系,在不影响临床诊断的基础上,修正并验证一种基于成人扫描参数的安全可行的儿童16层螺旋CT检查的扫描参数。方法利用16层螺旋CT,采用标准CT剂量指数(CTDI)测试仪、100mm笔型电离室,分别测量16cm和32cm直径模体在2mm×5mm准直宽度时不同kVp和mAs的CTDI;采用20cm标准水模,测量单一感兴趣区域(ROI)标准偏差值SD代表噪声水平。以成人扫描参数的不同百分比修正为不同年龄段儿童CT扫描的参数供临床验证。结果随着kVp和mAs的增加,CTDI随之增加,并与mAs呈线性关系;16cm直径模体的表面CTDI要高于32cm模体58%;实际的加权CTDIw值高于CT扫描仪显示的CTDIw;mAs相同时,kVp越高,图像噪声SD值越低,在kVp固定时,随着mAs的增加,图像噪声SD随之减少,当mAs增加到一定程度后,图像噪声趋向平稳。结论在不影响临床诊断的图像噪声水平下,根据年龄和体型特点,儿童16层CT检查mAs可以比成人降低10%~85%。  相似文献   

9.
OBJECTIVES: We sought to compare an 80-kVp coronary calcium scoring protocol with the standard protocol of 120 kVp in terms of accuracy and reproducibility and to assess its dose reduction potential. MATERIALS AND METHOD: An anthropomorphic heart phantom with calcium cylinders was scanned with different tube currents at 80 kVp and 120 kVp using a 16-slice multislice CT (MSCT) scanner. An adapted threshold for 80 kVp was calculated. Accuracy and reproducibility for calcium mass, volume, and Agatston score were analyzed using F-tests. The radiation doses needed to produce artifact-free images were determined. RESULTS: Accuracy (measurement errors: mass 120 kVp +4.6%, mass 80 kVp -6.9%, volume 120 kVp +78.8%, volume 80 kVp +58.2%) and reproducibility (F-tests: mass: P = 0.4998, volume: P = 0.9168, Agatston: P = 0.5422) were comparable at both tube voltages. Avoiding the appearance of artificial lesions, a CTDI(w,eff) of 10.7 mGy was needed at 120 kVp versus 4.6 mGy at 80 kVp (dose reduction of 57%). CONCLUSIONS: Using an 80-kVp protocol in coronary calcium scoring, a relevant dose reduction is possible without compromising reproducibility and accuracy.  相似文献   

10.
PURPOSE: To evaluate the dose from the computed tomographic (CT) portion of positron emission tomography (PET)/CT to determine minimum CT acquisition parameters that provide adequate attenuation correction. MATERIALS AND METHODS: Measurements were made with a PET/CT scanner or a PET scanner, five anthropomorphic phantoms (newborn to medium adult), and an ionization chamber. The CT dose was evaluated for acquisition parameters (10, 20, 40, 80, 160 mA; 80, 100, 120, 140 kVp; 0.5 and 0.8 second per rotation; 1.5:1 pitch). Thermoluminescent dosimetry was used to evaluate the germanium 68/gallium 68 rod sources. A phantom study was performed to evaluate CT image noise and the adequacy of PET attenuation correction as a function of CT acquisition parameters and patient size. RESULTS: The volumetric anthropomorphic CT dose index varied by two orders of magnitude for each phantom over the range of acquisition parameters (0.30 and 21.0 mGy for a 10-year-old with 80 kVp, 10 mAs, and 0.8 second and with 140 kVp, 160 mAs, and 0.8 second, respectively). The volumetric anthropomorphic CT dose index for newborn phantoms was twice that for adult phantoms acquired similarly. The rod source dose was 0.03 mGy (3-minute scan). Although CT noise varied substantially among acquisition parameters, its contribution to PET noise was minimal and yielded only a 2% variation in PET noise. In a pediatric phantom, PET images generated by using CT performed with 80 kVp and 5 mAs for attenuation correction were visually indistinguishable from those generated by using CT performed with 140 kVp and 128 mAs. With very-low-dose CT (80 kVp, 5 mAs) for the adult phantom, undercorrection of the PET data resulted. CONCLUSION: For pediatric patients, adequate attenuation correction can be obtained with very-low-dose CT (80 kVp, 5 mAs, 1.5:1 pitch), and such correction leads to a 100-fold dose reduction relative to diagnostic CT. For adults undergoing CT with 5 mAs and 1.5:1 pitch, the tube voltage needs to be increased to 120 kVp to prevent undercorrection.  相似文献   

11.
OBJECTIVES: The aim of the present study was to find out whether it was more effective to achieve a dose reduction in intraoral radiography with an increase in the tube potential setting (and a decrease of milliampere seconds) by an additional attenuation of the X-ray beam behind the film plane or by the use of digital radiography. A second aim was to find out if there were differences between the integral doses determined by two different detectors and two different phantoms. METHODS: The X-ray attenuation in this in vitro study was carried out using additional lead foils from the dental film packet fixed behind the film plane and with a metal film holder. The dose measurements were performed with two semiconductor detectors (Quart, Diados). Patient simulation was achieved by the Alderson phantom or by the use of a filter (6Al+0.8Cu). The absorbed doses were calculated by integrating an exponential function between the entrance dose and the body exit dose. In addition, organ doses were measured and the effective dose was determined according to the Implementation of the 1990 Recommendations of the ICRP (ICRP-60). RESULTS: The increase in tube potential levels did not provide a substantial reduction of the absorbed dose (90 kVp instead of 60 kVp: reduction to 92.4%), only a reduction of the entrance dose (by 30% to 35% at 90 kVp compared with 60 kVp). The use of three lead foils behind the film plane instead of one resulted in a 14.0% reduction of the absorbed dose (60 kVp); the use of a metal film holder resulted in a 27.8% reduction (60 kVp). When tube potential settings were increased, the dose reduction decreased. The absorbed dose was reduced to 52% when a storage phosphor plate was used instead of a film (60 kVp). It was possible to determine the amount of dose reduction with both the calculated absorbed dose and the effective doses. The integral doses obtained from the Alderson phantom showed values 5% higher than those obtained by the filter (r(2)=96.7%). For the comparison of the integral doses, the measurements performed with Quart had values higher by a factor of 1.139 than those performed with Diados. CONCLUSIONS: Instead of increasing the tube voltage or using additional lead foils or metal film holders, a substantial dose reduction is provided by digital radiography or more sensitive films while a low tube potential level is maintained and the milliampere seconds setting is reduced.  相似文献   

12.
The purpose of the study was to compare the image quality of film-screen (FS) and computed radiography (CR) for adult chest examinations across a range of beam energies. A series of images of the CDRAD threshold contrast detail detection phantom were acquired for a range of tube potential and exposure levels with both CR and FS. The phantom was placed within 9 cm of Perspex to provide attenuation and realistic levels of scatter in the image. Hardcopy images of the phantom were scored from a masked light-box by two scorers. Threshold contrast indices were used to calculate a visibility index (VI). The relationships between dose and image quality for CR and for FS are fundamentally different. The improvements in VIs obtained using CR at 75 kVp and 90 kVp were found to be statistically significant compared with 125 kVp at matched effective dose levels. The relative performance of FS and CR varies as a function of energy owing to the different k-edges of each system. When changing from FS to CR, the use of lower tube potentials may allow image quality to be maintained whilst reducing effective dose. A tube voltage of 90 kVp is indicated by this work, but may require clinical verification.  相似文献   

13.
OBJECTIVES: To determine the optimum X-ray spectrum in digital dental radiography once the dose around an implant and the diagnostic usefulness of the image are taken into account. MATERIALS AND METHODS: A Monte Carlo code (MCNP4B) was employed for computing the dose distribution across the bone-titanium interface. The X-ray spectra used were those met in digital dental radiography; 50-70 kVp, 2 mm Al total filtration, 5 kVp increment. RESULTS: The variation of the ratio of dose with as opposed to without implant against depth reaches maximum values at the bone-implant interface that vary between 2.9 and 3.2. For the same number of photon histories followed, the higher the tube potential setting, the greater the dose both in contact and inside the implant. CONCLUSION: In digital dental radiography, a 60-65 kVp spectrum accompanied by the known 30% reduction in mAs leads to lower dose to the patient for a diagnostically useful image.  相似文献   

14.
Perfusion CT studies of regional cerebral blood flow (rCBF), involving sequential acquisition of cerebral CT sections during IV contrast material administration, have classically been reported to be achieved at 120 kVp. We hypothesized that using 80 kVp should result in the same image quality while significantly lowering the patient's radiation dose, and we evaluated this assumption. In five patients undergoing cerebral CT survey, one section level was imaged at 120 kVp and 80 kVp, before and after IV administration of iodinated contrast material. These four cerebral CT sections obtained in each patient were analyzed with special interest to contrast, noise, and radiation dose. Contrast enhancement at 80 kVp is significantly increased (P < .001), as well as contrast between gray matter and white matter after contrast enhancement (P < .001). Mean noise at 80 kVp is not statistically different (P = .042). Finally, performance of perfusion CT studies at 80 kVp, keeping mAs constant, lowers the radiation dose by a factor of 2.8. We, thus, conclude that 80 kVp acquisition of perfusion CT studies of rCBF will result in increased contrast enhancement and should improve rCBF analysis, with a reduced patient's irradiation.  相似文献   

15.
PURPOSE: We sought to intraindividually compare computed tomography angiographies (CTAs) acquired at 80 kVp and 120 kVp with respect to vessel contrast, noise level, and radiation dose. MATERIAL AND METHODS: CTA was performed on a single-slice CT scanner using tube voltages of 80 kVp and 120 kVp in 29 patients with arteriovenous malformations. Mean Hounsfield Units (HU) were evaluated for different vessels and brain parenchyma. To determine contrast-to-noise ratios (CNRs), noise levels were estimated from phantom measurements. RESULTS: The calculated effective dose to male/female patients was 0.4/0.5 mSv for 80 kVp and 0.7/0.8 mSv for 120 kVp. CT density in blood vessels was between 297 and 458 HU for 80 kVp and 152 and 229 HU for 120 kVp (P<0.0001). Despite an increased noise level in the low-voltage images, the CNR was 26-59% higher at 80 kVp than at 120 kVp (P<0.05). CONCLUSION: The use of a reduced tube potential leads to improved CNR in CTA of the cerebral vasculature and a markedly reduced radiation exposure to patients.  相似文献   

16.
We investigate the ability of high spatial resolution (~120 μm) Ge-doped SiO2 TL dosimeters to measure photoelectron dose enhancement resulting from the use of a moderate to high-Z target (an iodinated contrast media) irradiated by 90 kVp X-rays. We imagine its application in a novel radiation synovectomy technique, modelled by a phantom containing a reservoir of I2 molecules at the interface of which the doped silica dosimeters are located. Measurements outside of the iodine photoelectron range are provided for using a stepped-design that allows insertion of the fibres within the phantom. Monte Carlo simulation (MCNPX) is used for verification. At the phantom medium I2-interface additional photoelectron generation is observed, ~60% above that in the absence of the I2, simulations providing agreement to within 3%. Percentage depth doses measured away from the iodine contrast medium reservoir are bounded by published PDDs at 80 kVp and 100 kVp.  相似文献   

17.
《Radiography》2017,23(3):222-228
IntroductionThe purpose of this study was to compare radiation dose measurements generated using a virtual radiography simulation with experimental dosimeter measurements for two radiation dose reduction techniques in digital radiography.MethodsEntrance Surface Dose (ESD) measurements were generated for an antero-posterior lumbar spine radiograph experimentally using NanoDOT™, single point dosimeters, for two radiographic systems (systems 1 and 2) and using Projection VR™, a virtual radiography simulation (system 3). Two dose reduction methods were tested, application of the 15% kVp rule, or simplified 10 kVp rule, and the exposure maintenance formula. The 15% or 10 kVp rules use a specified increase in kVp and halving of the mAs to reduce patient ESD. The exposure maintenance formula uses the increase in source-to-object distance to reduce ESD.ResultsIncreasing kVp from 75 to 96 kVp, with the concomitant decrease in mAs, resulted in percent ESD reduction of 59.5% (4.02–1.63 mGy), 60.8% (3.55–1.39 mGy), and 60.3% (6.65–2.64 mGy), for experimental systems 1 and 2, and virtual simulation (system 3), respectively. Increasing the SID (with the appropriate increase in mAs) from 100 to 140 cm reduced ESD by 22.3% 18.8%, and 23.5%, for experimental systems 1 and 2, and virtual simulation (system 3), respectively.ConclusionPercent dose reduction measurements were similar between the experimental and virtual measurement systems investigated. For the dose reduction practices tested, Projection VR™ provides a realistic alternate of percent dose reduction to direct dosimetry.  相似文献   

18.
A simple approach based on phantom measurements is proposed in this study to find the filtration, tube potential and antiscatter device that are optimal in respect of patient dose and image quality, at constant film-screen combination, film processing and viewing conditions. An original quasi-anthropomorphic chest phantom was exposed with 18 different beam qualities and three antiscatter devices. The entrance surface dose, organ doses and effective dose were estimated for each radiograph. The image quality was compared using two objective quality indexes, a contrast index and a scatter fraction, as well as two subjective indexes, a low contrast visualization index and a high contrast visualization index. It was found that for this X-ray unit, routinely using a 7:1 antiscatter grid, the optimal imaging technique is added filtration of 0.1 mm Cu+1 mm Al at a tube potential 100 kVp. Using a 25 cm air gap instead of the grid allows the tube potential to be increased to the upper limit of 120 kVp for this unit. The entrance surface dose of 0.075 mGy at 120 kVp with an air gap is less than half the value of the same quantity with a grid at 100 kVp and is significantly below the European reference level of 0.3 mGy. This phantom method, comprising both objective measurements and subjective estimation, is suitable for dose-image quality optimization in a clinical environment.  相似文献   

19.

Objectives:

To determine the optimal kVp setting for a particular cone beam CT (CBCT) device by maximizing technical image quality at a fixed radiation dose.

Methods:

The 3D Accuitomo 170 (J. Morita Mfg. Corp., Kyoto, Japan) CBCT was used. The radiation dose as a function of kVp was measured in a cylindrical polymethyl methacrylate (PMMA) phantom using a small-volume ion chamber. Contrast-to-noise ratio (CNR) was measured using a PMMA phantom containing four materials (air, aluminium, polytetrafluoroethylene and low-density polyethylene), which was scanned using 180 combinations of kVp/mA, ranging from 60/1 to 90/8. The CNR was measured for each material using PMMA as background material. The pure effect of kVp and mAs on the CNR values was analysed. Using a polynomial fit for CNR as a function of mA for each kVp value, the optimal kVp was determined at five dose levels.

Results:

Absorbed doses ranged between 0.034 mGy mAs−1 (14 × 10 cm, 60 kVp) and 0.108 mGy mAs−1 (14 × 10 cm, 90 kVp). The relation between kVp and dose was quasilinear (R2 > 0.99). The effect of mA and kVp on CNR could be modelled using a second-degree polynomial. At a fixed dose, there was a tendency for higher CNR values at increasing kVp values, especially at low dose levels. A dose reduction through mA was more efficient than an equivalent reduction through kVp in terms of image quality deterioration.

Conclusions:

For the investigated CBCT model, the most optimal contrast at a fixed dose was found at the highest available kVp setting. There is great potential for dose reduction through mA with a minimal loss in image quality.  相似文献   

20.
Sun Z  Lin C  Tyan Y  Ng KH 《Clinical imaging》2012,36(4):279-286
We studied the performance of three computed radiography and three direct radiography systems with regard to the image noise and entrance skin dose based on a chest phantom. Images were obtained with kVp of 100, 110, and 120 and mA settings of 1, 2, 4, 8, and 10. Significant differences of image noise were found in these digital chest radiography systems (P<.0001). Standard deviation was significantly different when the mAs were changed (P<.001), but it was independent of the kVp values (P=.08-.85). Up to 44% of radiation dose could be saved when kVp was reduced from 120 to 100 kVp without compromising image quality.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号