首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The objective of this investigation was to determine whether analysis of thallium-201 images as detected by quantitative single photon emission computed tomography after a single high oral dose of dipyridamole (300 mg) would accurately detect the presence of coronary artery disease and the anatomic location of the individual stenosis. Analyses were performed on 100 patients who concomitantly underwent diagnostic coronary arteriography and myocardial imaging. Tomographic myocardial perfusion defects were quantified using computer-generated polar maps. Eighty-four patients had significant coronary artery disease defined as greater than 50% luminal diameter stenosis. The sensitivity for detecting patients with coronary disease was 92% overall, 89% in patients without previous myocardial infarction and 97% in those with prior infarction. The technique had a sensitivity of 80, 87 and 51% for localizing coronary artery stenosis of the left anterior descending, the right coronary and the left circumflex artery, respectively. The corresponding specificity was 84, 92 and 92%. Furthermore, the presence of severe (greater than or equal to 70%) multivessel disease was identified with a sensitivity of 79% and a specificity of 87%. In conclusion, quantitative thallium-201 single photon emission computed tomography after oral dipyridamole has high sensitivity and specificity for diagnosing the presence of coronary disease, ascertaining the location of stenosed vessels and identifying the presence of multivessel disease.  相似文献   

2.
Objectives. We sought to ascertain the utility of adenosine thallium-201 tomography for assessing graft stenoses late after coronary artery bypass graft surgery.Background. Although pharmacologic perfusion imaging has been increasingly used in the assessment of patients with coronary artery disease, the value of this stress modality for detecting coronary artery bypass graft stenosis late after surgery is unknown.Methods. We studied 109 patients who underwent both adenosine thallium-201 tomography and coronary angiography at 6.7 ± 4.8 (mean ± SD) years after coronary artery bypass graft surgery. Adenosine thallium-201 tomography was assessed quantitatively by computer-generated polar maps of the myocardial thallium-201 activity.Results. On coronary angiography, significant graft stenoses were present in 68 patients, 65 of whom had a corresponding perfusion defect as shown by thallium-201 tomography (sensitivity 96%). Significant stenoses were present in 107 (37.8%) of 283 grafts. The overall specificity by quantitative tomography was 61%. Seventy percent of the apparently false positive perfusion defects could be explained on the basis of unbypassed native disease or by the presence of fixed defects in patients with previous myocardial infarction.Conclusions. Thus, results of adenosine thallium-201 tomography are nearly always abnormal in patients with late coronary graft stenosis. Most of the false positive defects appear to be due to either unbypassed native disease or a previous myocardial infarction.(J Am Coll Cardiol 1997;29:1290–5)  相似文献   

3.
Of all currently available techniques, thallium-201 single-photon emission computed tomography (SPECT) is the most time-tested noninvasive method for the detection of coronary artery disease (CAD). Recent pooled data show an overall sensitivity of 90% and a specificity of 70% for thallium-201 SPECT. Of patients with single-vessel coronary disease, 83% are identified by SPECT. Nearly all patients with double- and triple-vessel coronary disease (93% and 95%, respectively) are also identified. Thallium-201 SPECT imaging is also very effective in diagnosing CAD imaging is also very effective in diagnosing CAD using pharmacologic stress testing. In certain patient populations (e.g., in sedentary patients or those using anti-ischemic medications), pharmacologic stress testing with dipyridamole or adenosine may be a logical alternative to exercise testing. Moreover, many patients have physical disabilities that preclude appropriate exercise testing. Intravenous adenosine is a very potent direct coronary vasodilator, with the advantage of an ultrashort half-life, which eliminates the need to administer an antagonist in the majority of patients. In addition, the dosage of adenosine can be adjusted during the infusion, if necessary. The importance of thallium-201 SPECT during exercise or pharmacologic vasodilation transcends diagnosis, since it also plays an important role in the prognostic evaluation of patients with stable angina or postmyocardial infarction. Risk evaluation can be done with submaximal exercise electrocardiographic testing, but there is evidence that the addition of perfusion scintigraphy enhances the ability to predict future risk.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

4.
Objectives. This study sought to assess the diagnostic efficacy of adenosine technetium-99m (Tc-99m) sestamibi myocardial perfusion single-photon emission computed tomography (SPECT) in a consecutive series of female patients.Background. The utility of adenosine myocardial perfusion SPECT for the detection of coronary artery disease is not well defined in women because most studies have described a predominantly male population with a high prevalence of coronary artery disease.Methods. Of the 201 consecutive female patients in the study group who had undergone adenosine Tc-99m sestamibi myocardial perfusion SPECT, 130 had coronary angiography within 2 months of the nuclear test, and the other 71 had a low likelihood (<10%, mean [±SD] 5 ± 3%) of coronary artery disease. The SPECT protocol used separate acquisition of rest thallium-201 and adenosine Tc-99m sestamibi and was visually analyzed in 20 segments with a semiquantitative five-point scoring system (0 = normal; 4 = absent uptake).Results. The normaley rate in patients with a low likelihood of coronary artery disease was 93% (66 of 71). Among the catheterized group, the overall sensitivity, specificity and predictive accuracy of adenosine sestamibi SPECT for detecting coronary artery disease (⪰50% diameter stenosis) were 93% (87 of 94), 78% (28 of 36) and 88% (115 of 130), respectively. In the 103 patients without a prior myocardial infarction, the sensitivity, specificity and predictive accuracy were 91% (61 of 67), 78% (28 of 36) and 86% (89 of 103), respectively, for detecting ⪰50% diameter stenosis. Of particular interest, the sensitivity and specificity were as high in patients with nonanginal symptoms (93% and 69%, respectively) as in patients with angina (92% and 83%, respectively, p = NS). The sensitivity and specificity among patients with a relatively low (<25%), intermediate (between 25% and 75%) or high prescan likelihood of coronary artery disease (>75%) were similar: 82% and 82%, 93% and 73%, and 95% and 100%, respectively. The sensitivity and specificity for detecting individual diseased vessels (⪰50% diameter stenosis) were, respectively, 76% and 81% for the left anterior descending coronary artery, 44% and 90% for the left circumflex coronary artery and 75% and 77% for the right coronary artery.Conclusions. Adenosine Tc-99m sestamibi SPECT is an efficient protocol with high sensitivity and specificity for the detection of coronary artery disease in women irrespective of presenting symptoms or pretest likelihood of coronary artery disease and a high normaley rate. These findings are of particular clinical relevance because chest pain, anginal or otherwise, has been shown to be a frequent but a less specific marker for coronary artery disease among female patients.  相似文献   

5.
Two scintigraphic methods, resting dipyridamole and exercise thallium-201 myocardial perfusion imaging, to detect and localize coronary artery stenosis were compared in 32 patients suffering from coronary artery disease. The sensitivity of detecting a greater than 50% coronary stenosis was 94% for exercise thallium-201 perfusion imaging and 88% for dipyridamole thallium-201 perfusion imaging. The overall sensitivity and specificity of localizing a greater than 50% coronary stenosis by the two methods were also not significantly different. The results of the two scintigraphic methods were independent of the severity of coronary artery disease. Dipyridamole thallium-201 myocardial perfusion imaging provides a useful and safe alternative test for detecting and localizing coronary artery stenosis in patients unable to perform maximal exercise.  相似文献   

6.
The diagnostic performance of single-photon emission computed tomography (SPECT) and planar imaging of thallium-201 uptake for the detection of coronary artery disease (CAD) was compared in 79 patients who underwent both dipyridamole thallium-201 scintigraphy and coronary angiography. Clinical subgroups were assigned by severity of CAD, presence of a prior myocardial infarction and the number of narrowed coronary arteries. The overall detection of CAD was 89% for SPECT and 67% for planar (p less than 0.001). For the anterior vascular territory, sensitivities for SPECT and planar imaging were 69 and 44% (p less than 0.01), respectively; for the posterior vascular territory, sensitivities were 80 and 54% (p less than 0.01). Receiver-operating characteristic analysis, using a 5-point evaluation scale, was performed for the anterior and posterior vascular territories. Receiver-operating characteristic curves generated for SPECT and planar studies demonstrated improved diagnostic performance by SPECT in the anterior vascular territory, but showed similar performance in the posterior territory because of lower SPECT specificity despite higher sensitivity at clinically relevant decision thresholds. In each clinical subgroup of patients, the detection of CAD by SPECT was significantly superior to that by planar imaging, regardless of the severity of stenosis or the number of significantly narrowed coronary arteries, or whether a myocardial infarction was present. Thus, SPECT thallium-201 scintigraphy is an important and necessary clinical tool for detecting CAD after dipyridamole infusion.  相似文献   

7.
The diagnostic performance of rubidium-82 (Rb-82) positron emission tomography (PET) and thallium-201 (TI-201) single-photon emission-computed tomography (SPECT) for detecting coronary artery disease was investigated in 81 patients (52 men, 29 women). PET studies using 60 mCi of Rb-82 were performed at baseline and after intravenous infusion of 0.56 mg/kg dipyridamole in conjunction with handgrip stress. TI-201 SPECT was performed after dipyridamole-handgrip stress and, in a subset of patients, after treadmill exercise. Sensitivity, specificity and overall diagnostic accuracy were assessed using both visually and quantitatively interpreted coronary angiograms. The overall sensitivity, specificity and accuracy of PET for detection of coronary artery disease (>50% diameter stenosis) were 84,88 and 85%, respectively. In comparison, the performance of SPECT revealed a sensitivity of 84%, specificity of 53% (p < 0.05 vs PET) and accuracy of 79%. Similar results were obtained using either visual or quantitative angiographic criteria for severity of coronary artery disease. In 43 patients without prior myocardial infarction, the sensitivity for detection of disease was 71 and 73%, respectively, similar for both PET and SPECT. There was no significant difference in diagnostic performance between imaging modalities when 2 different modes of stress (exercise treadmill vs intravenous dipyridamole plus handgrip) were used with SPECT imaging. Thus, Rb-82 PET provides improved specificity compared with TI-201 SPECT for identifying coronary artery disease, most likely due to the higher photon energy of Rb-82 and attenuation correction provided by PET. However, post-test referral cannot be entirely excluded as a potential explanation for the lower specificity of TI-201 SPECT.  相似文献   

8.
C Kondo  M Hiroe  T Nakanishi  A Takao 《Circulation》1989,80(3):615-624
This study determined the feasibility and accuracy of quantitative 201Tl myocardial single-photon emission computed tomography (SPECT) after dipyridamole infusion to detect coronary obstructive lesions in children with Kawasaki disease. 201Tl distribution after dipyridamole infusion was measured in 23 normal children, and with these normal values, quantitative analysis of SPECT was performed in 49 patients. Thirty-four patients had coronary stenosis 90% or greater on angiograms. Side effects resulting from systemic vasodilation were observed in about 70%. Angina pectoris and ischemic ST changes were observed only in patients with coronary stenosis. These symptoms disappeared after aminophylline infusion. Results of visual and quantitative analysis of SPECT were compared. SPECT data were shown on two-dimensional polar maps, and the extent and severity scores were calculated. The sensitivity of SPECT for detection of overall coronary stenosis was 91% (visual analysis) and 88% (quantitative analysis). The specificity of SPECT was 60% visually and 93% quantitatively. The sensitivity of quantitative analysis to detect individual coronary stenosis was similar to that of visual analysis. However, the specificity of visual analysis to detect individual coronary artery stenosis was significantly less than that of quantitative analysis. From these data, we conclude that quantitative analysis of myocardial SPECT after dipyridamole infusion is a safe and accurate diagnostic method for identifying coronary stenosis in children with Kawasaki disease.  相似文献   

9.
L H Wang  J N Yuan  Z M Wu 《中华内科杂志》1989,28(7):386-9, 442
Fifteen patients with angina pectoris, seventeen with postmyocardial infarction angina and ten with normal coronary arteries were studied with stress TL-201 single photon emission computed tomography (SPECT). The sensitivity and specificity of SPECT for diagnosis of coronary heart disease were 91% and 90% respectively. SPECT showed better sensitivity (84%) for detecting diseased vessels. The sensitivity of SPECT for identifying one-vessel, two-vessel and three-vessel disease were 80%, 86% and 60%. The sensitivity and specificity of demonstrating involved coronary arteries by identifying the locations of myocardial perfusion defects were 79% and 92% for left anterior descending artery, 90% and 95% for left circumflex artery and 86% and 96% for right coronary artery. For localization of myocardial infarction in the posterior wall, posterior lateral wall, and posterior septum, SPECT is more accurate then ECG. The sensitivity of SPECT in detecting individual vessel is related to the severity of coronary stenosis. The more severe the coronary stenosis, the higher the sensitivity of SPECT. In conclusion, stress SPECT is a noninvasive, highly sensitive and accurate method for detecting and localizing coronary heart disease.  相似文献   

10.
Objectives. This study assessed the safety and diagnostic accuracy of adenosine stress myocardial perfusion scintigraphy for the detection of coronary artery disease using single-photon emission computed tomography (SPECT) in patients with significant aortic stenosis.Background. Exercise cardiac stress testing in patients with significant aortic stenosis is generally avoided because of concerns for safety. In addition, those studies that have analyzed the utility of exercise testing both with and without myocardial thallium-201 scintigraphy for the diagnosis of coronary artery disease have yielded low specificity. Currently, no safe and accurate means exists to noninvasively assess the presence, extent and severity of coronary artery disease in patients with significant aortic stenosis.Methods. The study included 35 patients with moderate to severe aortic stenosis (mean [±SD] aortic valve area 0.84 ± 0.16 cm2, range 0.5 to 1.2; mean maximal instantaneous aortic valve gradient 44.4 ± 15.9 mm Hg, range 20 to 84). All patients underwent a 6-min adenosine infusion (140 μg/kg body weight per min) protocol and either separate acquisition rest thallium-201/stress technetium-99m sestamibi or stress and 4-h redistribution thallium-201 SPECT. Visual 20-segment SPECT analysis used a standard five-point scoring system from 0 (normal tracer uptake) to 4 (absent uptake). The SPECT results were considered abnormal if more than two segments had a stress score ≥2. Hemodynamic, electrocardiographic and clinical responses were compared with those in a reference group of 100 consecutive age-matched patients undergoing adenosine SPECT who did not have aortic stenosis.Results. Hemodynamic responses during adenosine stress testing between the study and control patients demonstrated no significant difference in the net change in systolic blood pressure (18% of baseline vs. 14%, patients with aortic stenosis vs. control subjects), heart rate (21% vs. 19%), rate-pressure product (0% vs. 2%) or incidence of chest pain (23% vs. 35%) or transient second- (9% vs. 9%) or third-degree atrioventricular block (3% vs. 1%). In the 20 patients who had coronary angiography, sensitivity for detection of coronary artery disease was 92% (12 of 13) and specificity was 71% (5 of 7).Conclusions. In this preliminary study, adenosine was found to be well tolerated and diagnostically accurate in patients with moderate to severe aortic stenosis.  相似文献   

11.
腺苷负荷试验心肌核素显像对冠心病诊断价值的评估   总被引:7,自引:0,他引:7  
目的分析腺苷负荷试验心肌核素显像对于冠心病诊断的敏感性、特异性及其特点。方法住院患者同时行冠状动脉(冠脉)造影和腺苷负荷试验心肌核素显像。腺苷总量为840μg/kg,6min匀速静脉泵入,腺苷泵入3min时静脉推注^99m锝-甲氧基异丁基异腈核素显像925MBq,1.5h后进行心肌断层显像,若异常,次日行静息心肌显像。结果冠脉造影阳性50例中,心肌核素显像阳性44例。29例冠脉造影无明显狭窄,其中19例心肌核素显像阴性。腺苷负荷试验心肌核素显像对于冠心病诊断的敏感性和特异性为88.O%和65.5%。前降支病变40例,心肌核素前壁区域低灌注32例,回旋支病变27例,侧壁区域低灌注21例,右冠脉病变32例,下壁区域低灌注31例,右冠脉病变较前降支或回旋支病变的心肌核素显像阳性率高(P〈0.05)。结论腺苷负荷试验心肌核素显像对于冠心病诊断的敏感性、特异性较高。  相似文献   

12.
BACKGROUND: In patients with left bundle branch block (LBBB), conventional tests such as electrocardiography and myocardial scintigraphy poorly evaluate coronary artery disease. It has been reported that myocardial contrast echocardiography (MCE) is capable of identifying patients with a postinfarction contractile reserve and myocardial functional recovery, also allowing the early identification of late left ventricular remodeling. The purpose of this study was to evaluate, retrospectively, myocardial perfusion in selected patients with LBBB. METHODS: Thirty patients (mean age 56 +/- 8 years) with LBBB, 15 with normal coronary arteries at angiography and 15 with a previous myocardial infarction and a critical one-vessel residual stenosis at angiography, underwent MCE from June 2000 to May 2001. MCE results were compared with rest thallium-201 myocardial scintigraphy. RESULTS: Among 15 LBBB patients with normal coronary arteries, MCE demonstrated normal perfusion in 14 patients, whereas 1 subject showed an impairment of septal perfusion. In the same group, rest thallium-201 myocardial scintigraphy showed an impaired septal perfusion in 14 patients, whereas 1 subject had a normal perfusion (MCE specificity 93% vs myocardial scintigraphy specificity 7%). Among 15 LBBB patients with coronary artery disease, MCE correctly identified a contrast defect in 14/15 patients, whereas rest thallium-201 myocardial scintigraphy demonstrated a perfusion defect in 15/15 patients (MCE sensitivity 93% vs scintigraphy sensitivity 100%). The two techniques showed a good agreement as for myocardial perfusion in the anterior wall (86.6% anterobasal; 86.6% mid-anterior; 80% distal anterior), the inferior wall (86.6%), the distal segment of the posterior lateral wall (83.3%), but a low concordance was found as for the basal septum (16.6%) and middistal septum (33.3%). CONCLUSIONS: MCE allows a diagnostic benefit in the detection of microvascular damage in patients with LBBB and unknown coronary artery disease, also in the presence of discordance with rest thallium-201 myocardial scintigraphy.  相似文献   

13.
Twenty-seven patients with angina pectoris, 24 with postmyocardial infarction angina and 7 with normal coronary arteries were examined by exercise thallium-201 emission computed tomography (SPECT) and planar scintigraphy. Exercise SPECT was compared with the reperfusion imaging obtained approximately 2 to 3 hours after exercise. The sensitivity and specificity of demonstrating involved coronary arteries by identifying the locations of myocardial perfusion defects were 96 and 87% for right coronary artery, 88 and 89% for left anterior descending artery (LAD) and 78 and 100% for left circumflex artery (LC). These figures are higher than those for planar scintigraphy (85 and 87% for right coronary artery, 73 and 89% for LAD and 39 and 100% for LC arteries). In patients with 3-vessel disease, sensitivity of SPECT (100, 88 and 75% for right coronary artery, LAD and LC, respectively) was higher than planar imaging (88, 63 and 31%, respectively), with a significant difference for LC (p less than 0.05). In 1, 2 and 0-vessel disease the sensitivity and specificity of the 2 techniques were comparable. Multivessel disease was more easily identified as multiple coronary involvement than planar imaging with a significant difference in 3-vessel disease (p less than 0.05). In conclusion, stress SPECT provides useful information for the identification of LC lesions in coronary heart disease, including 3-vessel involvement.  相似文献   

14.
OBJECTIVE: Exercise thallium-201 (201T1) single photon emission computed tomography (SPECT) has been used to detect potential ischaemia in the left ventricular myocardium but not in the right ventricle. The purpose of this study was to establish the clinical usefulness of a right ventricular polar map of 201T1 SPECT for visualisation of exercise-induced right ventricular ischaemia. METHODS: Myocardial 201T1 SPECT was obtained immediately after treadmill exercise in 97 patients with suspected coronary artery disease. A region of interest was placed over the right ventricle (RV) on post-stress transaxial images. Short axis images of this region were generated and reconstructed as a bull's eye polar map. Normal ranges of RV 201T1 uptake were determined in 12 patients with normal coronary arteries. Scintigraphic criteria for identifying RV perfusion abnormality were derived from 25 patients with right coronary artery (RCA) stenosis greater than 75%. These criteria were applied to 60 consecutive patients with suspected coronary artery disease. RESULTS: Perfusion defects in the RV were larger in patients with proximal RCA stenosis than in those with distal RCA stenosis (mean (SD) 28 (16)% v 6 (5)%, P < 0.001). The sensitivity and specificity of the RV polar map for the detection of proximal RCA stenosis were 67% (8/12) and 98% (47/48), respectively. RV perfusion defects became undetectable in 9 patients who had successful percutaneous transluminal coronary angioplasty to a proximal RCA lesion. CONCLUSIONS: A right ventricular polar map display was useful for visualising exercise-induced right ventricular ischaemia.  相似文献   

15.
To evaluate its efficacy in detecting myocardial ischemia in children, iodine-123-labeled 15-(p-iodophenyl)-3-R, S-methylpentadecanoic acid (BMIPP) myocardial single photon emission computed tomography (SPECT) imaging was performed in 16 pediatric patients with Kawasaki disease (KD, 11 male, 5 female; mean age and range: 13 years 8 months and 8 years 11 months to 17 years 7 months). Five children with chest pain and no cardiac disease were studied as controls (2 male, 3 female; mean age and range: 13 years 4 months and 9 years 4 months to 17 years 11 months). Selective coronary angiography was also performed in the 16 patients to evaluate the location of coronary stenosis and coronary aneurysms. The SPECT images were expressed as polar maps (Bull's eye maps) and the 'defect' area was defined as where the uptake of BMIPP was less than the standardized BMIPP images of the 5 control children. In the 16 patients, 33 segments had coronary aneurysms and 10 (10/33: 30.3%) had significant coronary stenosis on selective coronary angiography. Nine of the 10 (90%) segments with significant coronary stenosis showed a defect on the BMIPP image whereas only 6 of the 23 (26.1%) segments without coronary stenosis showed a defect on BMIPP imaging. The sensitivity of BMIPP SPECT imaging for detection of coronary stenosis was 90% (9/10) and its specificity was 73.9% (17/23), whereas the sensitivity of (201)Tl SPECT imaging was 80% (8/10) and its specificity was 60% (14/23). There was no significant difference between the BMIPP and 201Tl SPECT images in either the sensitivity or specificity for the detection of coronary stenosis. In the present series, only one case had discordant BMIPP uptake (BMIPP uptake < (201)Tl uptake) in which there was a large coronary aneurysm and re-canalization after complete obstruction at segment 1 of the right coronary artery. This discordant BMIPP uptake reflects the possibility of ischemic but viable myocardium after re-canalization of a large aneurysm in KD. In conclusion, BMIPP SPECT imaging is useful for detecting the areas of ischemic myocardium caused by coronary artery stenosis in children with KD.  相似文献   

16.
Exercise echocardiography and exercise thallium-201 (201Tl) single photon emission computed tomography (SPECT) were performed in 152 patients with suspected coronary artery disease, including 61 patients with old myocardial infarction. All patients underwent coronary arteriography, and coronary artery disease was defined as > or = 75% diameter stenosis. Digital two-dimensional echocardiography was performed before and after the treadmill exercise test, and wall motion abnormality was evaluated using quad-screen. Sensitivity and specificity for the diagnosis of coronary artery disease were similar for the 2 exercise tests (77% and 80% for echocardiography and 75%, and 83% for SPECT, respectively). Diagnoses for one-vessel disease, 2-vessel disease and 3-vessel disease were similar for echocardiography (79%, 72% and 77%, respectively) and SPECT (74%, 75% and 77%, respectively). Sensitivity for the diagnosis of ischemia at the area remote from infarct area was low for both exercise echocardiography and exercise SPECT (45% and 48%, respectively). Exercise echocardiography has comparable diagnostic value to SPECT for the detection of coronary artery disease. However, both exercise tests have limitations for the diagnosis of ischemia at the area remote from infarct area.  相似文献   

17.
Results of exercise thallium-201 myocardial perfusion images, obtained in 60 women suspected of having coronary artery disease, were correlated with coronary angiographic findings. Thirty-two patients had no significant coronary artery disease; 28 patients had severe coronary artery disease defined as 70 percent or greater diameter narrowing of one vessel (14 patients) or multiple vessels (14 patients). The exercise electrocardiogram was positive in 17 patients (9 with and 8 without coronary artery disease), negative in 16 patients (3 with and 13 without coronary artery disease) and inconclusive in 27 patients (16 with and 11 without coronary artery disease). The exercise thallium-201 scintigram showed exercise-induced defects (reversible ischemia) in 21 patients with coronary artery disease, a fixed defect in 1 patient with single vessel disease and previous transmural infarction, but was normal in the remaining 6 patients, who had single vessel disease. The exercise thallium-201 scintigram in subjects with no coronary artery disease was normal in 28, showed an exercise-induced defect in 1 subject and a fixed defect in the remaining 3 subjects. These fixed defects involved the anterolateral segment in the anterior projection and are thought to be due to attenuation of activity by the overlying breasts. Thus, the sensitivity of the exercise electrocardiogram was 32 percent and the specificity 41 percent. In contrast, the sensitivity of exercise thallium-201 scintigraphy was 75 percent and the specificity 97 percent if only exercise-induced defects were considered abnormal and 79 and 88 percent, respectively, if all fixed defects were considered abnormal.It is concluded that exercise thallium scintigraphy is useful in women suspected of having coronary artery disease. Attenuation of activity by breasts may affect the specificity but not the sensitivity. The exercise electrocardiogram is neither sensitive nor specific in this group.  相似文献   

18.
腺苷负荷试验心肌灌注显像诊断冠心病的临床价值   总被引:42,自引:2,他引:42  
目的 评价腺苷负荷试验心肌灌注显像诊断冠心病的准确性。方法 对 89例临床疑诊冠心病患者 ,分别静脉注射腺苷 ,剂量为 14 0 μg·kg-1·min-1,用药时间 6min(总剂量为 0 8mg/kg) ,注射过程中 ,行心电监测 ,观察患者的症状、血压和心率 ,于注射腺苷 3min末 ,静脉注射核素显像剂99mTc MIBI 92 5MBq ,1h后行心肌灌注断层显像 ,若显像异常 ,次日行静息心肌显像。所有患者行冠状动脉造影。结果 在 89例患者中 ,31例冠状动脉造影显示明显的冠状动脉狭窄病变 ,其中单支病变 10例 ,二支病变 11例 ,三支病变 10例。累及左前降支 2 8支 ,左回旋支 18支 ,右冠状动脉 16支 ,左主干 2支。腺苷负荷试验心肌灌注显像诊断冠心病的敏感性为 71%、特异性为 91%、阳性预测值81%、阴性预测值 84 %、准确性为 84 %。诊断单支、二支和三支冠状动脉病变患者的敏感性分别为5 0 %、73%、90 %。腺苷负荷试验心肌灌注显像判断血管病变的敏感性 77%、特异性 96 %、准确性 92 %。结论 腺苷负荷心肌灌注显像诊断冠心病敏感性及特异性均较高 ,具有重要的临床应用价值。  相似文献   

19.
BACKGROUND: Adenosine has been available for use in myocardial perfusion single-photon emission computed tomography (SPECT) in Japan since 2005. The purpose of this study was to evaluate the safety of and tolerance to thallium-201 myocardial perfusion SPECT with intravenous adenosine infusion in Japanese patients with suspected coronary artery disease. METHODS AND RESULTS: Two hundred and six consecutive patients who underwent an adenosine infusion (120 mug . kg(-1) . min(-1)) SPECT at Sumitomo Besshi Hospital (Niihama, Japan) were investigated. The effects of adenosine infusion were monitored for each patient. A coronary angiography was performed in 81 patients. Adenosine infusion significantly decreased blood pressure and increased heart rate. Adverse reactions were observed in 161 patients (78.2%). Most reactions were transient, disappearing soon after the termination of adenosine infusion. No serious adverse reactions, such as acute myocardial infarction or death, occurred. Adenosine infusion was terminated in 3 patients (1.5%) because of near syncope or sustained 2:1 atrioventricular block. Electrocardiographic changes occurred in 15 patients (7.3%). Self-assessed scoring after SPECT showed that the patients were very tolerant (74.6% of 177 patients) of adenosine infusion myocardial SPECT. The sensitivity and specificity were 75.0% and 69.7%, respectively. CONCLUSIONS: Adenosine infusion myocardial SPECT is safe and well tolerated in the Japanese population, despite the frequent occurrence of minor adverse reactions.  相似文献   

20.
OBJECTIVES: The usefulness of coronary flow reserve measurement in the left circumflex coronary artery by transthoracic Doppler echocardiography to detect myocardial ischemia was compared with exercise thallium-201 single photon emission computed tomography (SPECT). METHODS: Transthoracic Doppler echocardiography was performed in 110 patients with suspected coronary artery disease. Color Doppler signals of the left circumflex coronary artery flow in the apical four-chamber view were identified, and the velocities at rest and during hyperemia recorded for calculation of coronary flow reserve by the pulsed Doppler method. All patients underwent SPECT within 1 week of the transthoracic Doppler echocardiographic study. RESULTS: Coronary flow reserve in the left circumflex coronary artery was measured in 79 (72%) of 110 patients. SPECT revealed reversible perfusion defect in the left circumflex coronary artery territories in 12 of 69 patients excluding those with multivessel disease. Coronary flow reserve < 2.0 had a sensitivity of 92% and specificity of 96% for reversible perfusion defect detected by SPECT. CONCLUSIONS: Noninvasive coronary flow reserve measurement in the left circumflex coronary artery by transthoracic Doppler echocardiography can estimate myocardial ischemia in the left ventricular lateral regions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号