首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 46 毫秒
1.
研制了用多孔气体扩散电极的电化学传感器和大规模低功耗IC器件组成的一氧化碳个体监测仪器。检测浓度范围为0~100mg·m-3,便于个体携带。与相适配的支持部件相连接,可组成无人值守自动监测系统。该仪器具有直读瞬时浓度和时间加权平均浓度,剂量值读出以及8h以上的数据记忆与再读出等功能。  相似文献   

2.
本介绍了以纯三聚甲醛为原料的甲醛扩散管,扩散出来的三聚甲醛,随载气通过热催化分解成单分子甲醛。讨论了扩散管结构和各种参数对扩散率的影响。扩散管的稳定时间为一年。用AHMT比色法作为参比方法,对扩散管配制甲醛标准气体的准确度进行了验证,三聚甲醛热分解效率在99%以上。三聚甲醛扩散管的扩散率2-50μg/min范围,重量法测定总不确定度为4.5%。将其转换成甲醛扩散率总不确定度为4.7%。  相似文献   

3.
本介绍了以色谱纯苯为原料的苯扩散管气体标准物质,用重量法测定了扩散率。讨论了扩散管结构和温度对扩散率的影响。扩散管的稳定时间为8个月。扩散率在0.5-10μg/min范围,重量法测定苯扩散率总不确定为4%。  相似文献   

4.
扩散-电极法测定食品中氟   总被引:1,自引:0,他引:1  
样品中氟在扩散盒中与硫酸作用生成氟化氢,经扩散吸附在扩散盒的碱膜上。碱膜用缓冲液溶解后,氟化物含量由氟离子选择电极测定。用本法对菜花、菠菜、大米、鱼片干四种样品以及玉米氟样品的氟进行了精密度和准确度试验。相对标准偏差在5%以内,回收率为90%~103%,最小检测量为0.24μg。该法可直接测定含氟量在0.5~100mg/kg(干重)的食品。  相似文献   

5.
林少彬  王倩 《卫生研究》1995,24(2):111-113
样品中氟在扩散盒中与硫酸作用生成氟化氢,经扩散吸附在扩散盒的碱膜上。碱膜用缓冲液溶解后,氟化物含量由氟离子选择电极测定。用本法对菜花、菠菜、大米、鱼片干四种样品以及玉米氟样品的氟进行了精密度和准确度试验。相对标准偏差在5%以内,回收率为90%~103%,最小检测量为0.24μg。该法可直接测定含氟量在0.5~100mg/kg(干重)的食品。  相似文献   

6.
目前我国各医院对医用氧气的收费仍沿用过去的计时收费的方法,尚未有一个准确有效的监测办法。由于流量计结构复杂、体积过大、造价高等原因,一直未在医院推广。我们针对医用气体流量的特点,利用现代科学技术设计了一种体积小、原理简单、成本低廉、安装方便、性能可靠、精度高的流量测量器。它的设计原理是,利用流体或气体在其流量增大时,人为使其局部缩小产生束流,而在测量部位束流口下方(管)内产生负压,再通过压力传感器将这个信号转换为不同介质的流量信号,从而达到测量流量的目的。该负压式流量测量器(见图1)的结构是:一…  相似文献   

7.
目的 研制一种可检测空气中氧(O2)、二氧化碳(CO2)、一氧化碳(CO)3种气体浓度并对超标或低于标准限可自动报警的一体化小型气体监测报警仪,以保障官兵健康和生命安全。方法 设计三通道扩散式采样,气体传感器检测被测气体,产生相应的电信号,信号采集放大后进行转换为标准信号,逐一送入模数转换电路,被中央处理器读取,经程序计算分析后,把最终结果送去显示,浓度值超过预置的报警值则触发声光报警。结果 研制的报警仪主要战术技术指标:体积为150 mm×30 mm×200 mm;工作温度为5-40 ℃;O2测定范围为0%-100%,,最低检出限为0.1%;CO2测定范围为0%-5%,最低检出限为0.01%;CO测定范围为0-625 nag·m-3,最低检出限为0.1 mg·m-3。实验室与现场试验结果表明,与国家标准规定的市售仪器测定结果比较无显著性差异。结论 研制的坑道气体报警仪,具备小型便携、一体化组合、智能报警等特点,抗干扰性能强,稳定性好,适合我军各类坑道使用。  相似文献   

8.
9.
10.
采用基于K-ε湍流模型的CFD方法,对氯气在公共大空间建筑内的扩散情况进行仿真分析。首先利用Gambit软件进行建模,而后输入到Fluent软件进行仿真模拟,得到氯气的扩散云图,并且通过分析比较不同空调工况下的模拟结果数据,发现氯气重气贴地扩散趋势明显。空调工作时,室内流场对其扩散影响显著,氯气扩散速度变快,范围变大,但浓度比空调不工作时相对较低。通过研究氯气的扩散规律和影响其扩散的因素,可以优化大空间建筑通风设计,为化学恐怖袭击的应急处置提供参考。  相似文献   

11.
目的:研制用于柱头进样气相色谱仪一体化甲烷化器及对一氧化碳(CO)检测条件进行优化。方法:利用气相色谱仪高精度的加热控温功能在柱头进样器恒温箱上安装研制的U型甲烷化器。另外,通过气相色谱动力学与多相催化动力学的结合对CO的检测条件进行优化。结果:在最佳条件下,方法的线性范围为2.5×10-4~0.8μg,相关系数r≥0.998;检出限为0.25 mg/m3(进样1 m l);相对标准偏差和回收率分别为0.7%~4.6%(0.25~400 mg/m3)和92.6%~99.5%。结论:研制的方法具有可操作性,优于分体式测量模式,较好地解决了CO检测条件难以掌握的难题。方法操作简便,快速,准确,灵敏度和精密度高,适用于环境空气中CO的检测。  相似文献   

12.
目的 探讨急性中、重度一氧化碳 (CO)中毒患者血一氧化氮 (NO)含量及其与动脉氧分压 (PaO2 )、二氧化碳分压 (PaCO2 )的关系。方法 应用硝酸还原酶法检测了急性CO中度中毒 14例、重度中毒 2 1例患者的血NO含量 ,并与PaO2 、PaCO2 进行相关分析。结果 急性中、重度CO中毒组患者血NO含量分别为 (36 .6 +9.9)、(35 .7+10 .7) μmol/L ,均明显低于对照组 [(6 4 .9+14 .3)μmol/L],差异有显著性 (P <0 .0 1) ;而中度和重度中毒组间比较 ,差异无显著性 (P >0 .0 5 )。直线相关分析表明 ,急性中、重度CO中毒患者血NO含量均与PaO2 呈明显正相关 ,r值分别为 0 .92 8、0 .891,均P <0 .0 1;与PaCO2 无明显相关性。结论 急性中、重度CO中毒患者的缺氧可能是导致血NO含量减少的重要原因 ,为吸入低浓度NO治疗急性CO中毒提供了依据  相似文献   

13.
Summary This study examined the influence of exposure to ambient carbon monoxide resulting in final carboxyhemoglobin (COHb) levels of approximately 5.0% on the ability to process information during motor performance. Subjects (n=16) performed a primary reciprocal tapping task and a secondary digit manipulation task singly and/or concurrently during 2.5 h exposure to room air (0 ppm CO) or 100 ppm CO. Five levels of tapping difficulty and two levels of digit manipulation were employed. Tapping performance was unaffected when COHb levels were as high as 5%. However, at this level of COHb it was noted that CO exposure interacted with task difficulty of both tasks to influence reaction time on the digit manipulation task. It was concluded that motor performance was not influenced by exposure to CO leading to COHb concentrations of 5%. Task difficulty was a significant factor mediating behavioral effects of CO exposure.This work was supported in part by the U.S. Environmental Protection Agency under grant R808177010 and the U.S. National Institutes of Health under grant RR07099. (Although the research described in this article has been funded in part by the EPA through grant RR07099 to the Institute of Environmental Stress, it has not been subjected to the agency's required peer and policy review and therefore does not necessarily reflect the views of the angency and no official endorsement should be inferred.)  相似文献   

14.
目的:探讨一氧化碳中毒迟发性脑病的发病机制及治疗。方法:回顾性分析21例一氧化碳中毒迟发性脑病的临床资料。结果:21例患者一氧化碳中毒后均以痴呆、震颤麻痹和精神症状为主,MRI提示大脑白质内弥漫性病变,BEAM表现为弥散的慢活动。治疗主要给于激素、高压氧、自由基清除剂治疗。结论:一氧化碳中毒迟发性脑病的治疗愈后与昏迷时间长短、年龄有关。  相似文献   

15.
A comparative cross-sectional study was conducted to determine tollbooth carbon monoxide (CO) levels and carboxyhaemoglobin (COHb) levels among the tollbooth operators and office workers in the Klang Valley, Kuala Lumpur. All tollbooths were equipped with well functioning air-conditioning. The total number of respondents was 180: 90 toll operators and 90 office workers aged between 19 and 52 years. The highest peak of CO level recorded was 61 ppm. The highest average peak CO level within a shift was 30 ppm. The CO level was higher during peak traffic at 6.00 - 8.00 a.m. There was no significant correlation between average peak CO level with vehicle load (r = -0.007, p = 0.474). The toll operators' median COHb level (1.0%, IQR = 0.8%) was significantly higher (p = 0.008) compared to office workers (0.7%, IQR = 0.8). There was a weak and significant correlation between COHb levels with average peak CO levels (r = 0.228, p = 0.031). In conclusion, tollbooth operators were chronically exposed to CO leading to higher COHb levels compared to office workers.  相似文献   

16.
17.
目的:对采用压差法测量医用气体流量的测量原理、结构和工艺等因素引入的不确定度进行分析.方法:利用液体流经节流装置时所产生的压差测量气体流量.结果:合成不确定度μc=1.364%,满足产品设计要求.结论:压差传感器测量方法准确可靠,能够满足对医用气体流量测量的要求.  相似文献   

18.
19.
设为首页 | 免责声明 | 关于勤云 | 加入收藏