共查询到20条相似文献,搜索用时 78 毫秒
1.
Kiyofumi Yamada Yan Song Daniel S Hippe Jie Sun Li Dong Dongxiang Xu Marina S Ferguson Baocheng Chu Thomas S Hatsukami Min Chen Cheng Zhou Chun Yuan 《Journal of cardiovascular magnetic resonance》2012,14(1):81
Background
Carotid intraplaque hemorrhage (IPH) and lipid rich necrotic core (LRNC) have been associated with accelerated plaque growth, luminal narrowing, future surface disruption and development of symptomatic events. The aim of this study was to evaluate the quantitative relationships between high intensity signals (HIS) in the plaque on TOF-MRA and IPH or LRNC volumes as measured by multicontrast weighted CMR.Methods
Seventy six patients with a suspected carotid artery stenosis or carotid plaque by ultrasonography underwent multicontrast carotid CMR. HIS presence and volume were measured from TOF-MRA MIP images while IPH and LRNC volumes were separately measured from multicontrast CMR.Results
For detecting IPH, HIS on MIP images overall had high specificity (100.0%, 95% CI: 93.0 – 100.0%) but relatively low sensitivity (32%, 95% CI: 20.8 – 47.9%). However, the sensitivity had a significant increasing relationship with underlying IPH volume (p = 0.033) and degree of stenosis (p = 0.022). Mean IPH volume was 2.7 times larger in those with presence of HIS than in those without (142.8 ± 97.7 mm3 vs. 53.4 ± 56.3 mm3, p = 0.014). Similarly, mean LRNC volume was 3.4 times larger in those with HIS present (379.8 ± 203.4 mm3 vs. 111.3 ± 122.7 mm3, p = 0.001). There was a strong correlation between the volume of the HIS region and the IPH volume measured from multicontrast CMR (r = 0.96, p < 0.001).Conclusion
MIP images are easily reformatted from three minute, routine, clinical TOF sequences. High intensity signals in carotid plaque on TOF-MRA MIP images are associated with increased intraplaque hemorrhage and lipid-rich necrotic core volumes. The technique is most sensitive in patients with moderate to severe stenosis. 相似文献2.
Zhaoyang Fan Wei Yu Yibin Xie Li Dong Lixin Yang Zhanhong Wang Antonio Hernandez Conte Xiaoming Bi Jing An Tianjing Zhang Gerhard Laub Prediman Krishan Shah Zhaoqi Zhang Debiao Li 《Journal of cardiovascular magnetic resonance》2014,16(1):53
Background
Multi-contrast weighted imaging is a commonly used cardiovascular magnetic resonance (CMR) protocol for characterization of carotid plaque composition. However, this approach is limited in several aspects including low slice resolution, long scan time, image mis-registration, and complex image interpretation. In this work, a 3D CMR technique, named Multi-contrast Atherosclerosis Characterization (MATCH), was developed to mitigate the above limitations.Methods
MATCH employs a 3D spoiled segmented fast low angle shot readout to acquire data with three different contrast weightings in an interleaved fashion. The inherently co-registered image sets, hyper T1-weighting, gray blood, and T2-weighting, are used to detect intra-plaque hemorrhage (IPH), calcification (CA), lipid-rich necrotic core (LRNC), and loose-matrix (LM). The MATCH sequence was optimized by computer simulations and testing on four healthy volunteers and then evaluated in a pilot study of six patients with carotid plaque, using the conventional multi-contrast protocol as a reference.Results
On MATCH images, the major plaque components were easy to identify. Spatial co-registration between the three image sets with MATCH was particularly helpful for the reviewer to discern co-existent components in an image and appreciate their spatial relation. Based on Cohen’s kappa tests, moderate to excellent agreement in the image-based or artery-based component detection between the two protocols was obtained for LRNC, IPH, CA, and LM, respectively. Compared with the conventional multi-contrast protocol, the MATCH protocol yield significantly higher signal contrast ratio for IPH (3.1 ± 1.3 vs. 0.4 ± 0.3, p < 0.001) and CA (1.6 ± 1.5 vs. 0.7 ± 0.6, p = 0.012) with respect to the vessel wall.Conclusions
To the best of our knowledge, the proposed MATCH sequence is the first 3D CMR technique that acquires spatially co-registered multi-contrast image sets in a single scan for characterization of carotid plaque composition. Our pilot clinical study suggests that the MATCH-based protocol may outperform the conventional multi-contrast protocol in several respects. With further technical improvements and large-scale clinical validation, MATCH has the potential to become a CMR method for assessing the risk of plaque disruption in a clinical workup. 相似文献3.
Zechen Zhou Rui Li Xihai Zhao Le He Xiaole Wang Jinnan Wang Niranjan Balu Chun Yuan 《Journal of cardiovascular magnetic resonance》2015,17(1)
Background
Multi-contrast vessel wall cardiovascular magnetic resonance (CMR) has demonstrated its capability for atherosclerotic plaque morphology measurement and component characterization in different vasculatures. However, limited coverage and partial volume effect with conventional two-dimensional (2D) techniques might cause lesion underestimation. The aim of this work is to evaluate the performance in a) blood suppression and b) vessel wall delineation of three-dimensional (3D) multi-contrast joint intra- and extracranial vessel wall imaging at 3T.Methods
Three multi-contrast 3D black blood (BB) sequences with T1, T2 and heavy T1 weighting and a custom designed 36-channel neurovascular coil covering the entire intra- and extracranial vasculature have been used and investigated in this study. Two healthy subjects were recruited for sequence parameter optimization and twenty-five patients were consecutively scanned for image quality and blood suppression assessment. Qualitative image scores of vessel wall delineation as well as quantitative Signal-to-Noise Ratio (SNR) and Contrast-to-Noise Ratio (CNR) were evaluated at five typical locations ranging from common carotid arteries to middle cerebral arteries.Results
The 3D multi-contrast images acquired within 15mins allowed the vessel wall visualization with 0.8 mm isotropic spatial resolution covering intra- and extracranial segments. Quantitative wall and lumen SNR measurements for each sequence showed effective blood suppression at all selected locations (P < 0.0001). Although the wall-lumen CNR varied across measured locations, each sequence provided good or adequate image quality in both intra- and extracranial segments.Conclusions
The proposed 3D multi-contrast vessel wall technique provides isotropic resolution and time efficient solution for joint intra- and extracranial vessel wall CMR. 相似文献4.
Jochen M Grimm Andreas Schindler Tobias Freilinger Clemens C Cyran Fabian Bamberg Chun Yuan Maximilian F Reiser Martin Dichgans Caroline Freilinger Konstantin Nikolaou Tobias Saam 《Journal of cardiovascular magnetic resonance》2013,15(1):44
Background
To determine if black-blood 3 T cardiovascular magnetic resonance (bb-CMR) can depict differences between symptomatic and asymptomatic carotid atherosclerotic plaques in acute ischemic stroke patients.Methods
In this prospective monocentric observational study 34 patients (24 males; 70 ±9.3 years) with symptomatic carotid disease defined as ischemic brain lesions in one internal carotid artery territory on diffusion weighted images underwent a carotid bb-CMR at 3 T with fat-saturated pre- and post-contrast T1w-, PDw-, T2w- and TOF images using surface coils and Parallel Imaging techniques (PAT factor = 2) within 10 days after symptom onset. All patients underwent extensive clinical workup (lab, brain MR, duplex sonography, 24-hour ECG, transesophageal echocardiography) to exclude other causes of ischemic stroke. Prevalence of American Heart Association lesion type VI (AHA-LT6), status of the fibrous cap, presence of hemorrhage/thrombus and area measurements of calcification, necrotic core and hemorrhage were determined in both carotid arteries in consensus by two reviewers who were blinded to clinical information. McNemar and Wilcoxon''s signed rank tests were use for statistical comparison. A p-value <0.05 was considered statistically significant.Results
Symptomatic plaques showed a higher prevalence of AHA-LT6 (67.7% vs. 11.8%; p < 0.001; odds ratio = 12.5), ruptured fibrous caps (44.1% vs. 2.9%; p < 0.001; odds ratio = 15.0), juxtaluminal thrombus (26.5 vs. 0%; p < 0.01; odds ratio = 7.3) and intraplaque hemorrhage (58.6% vs. 11.8%; p = 0.01; odds ratio = 3.8). Necrotic core and hemorrhage areas were greater in symptomatic plaques (14.1 mm2 vs. 5.5 mm2 and 13.6 mm2 vs. 5.3 mm2; p < 0.01, respectively).Conclusion
3 T bb-CMR is able to differentiate between symptomatic and asymptomatic carotid plaques, demonstrating the potential of bb-CMR to differentiate between stable and vulnerable lesions and ultimately to identify patients with low versus high risk for cardiovascular complications. Best predictors of the symptomatic side were a ruptured fibrous cap, AHA-LT 6, juxtaluminal hemorrhage/thrombus, and intraplaque hemorrhage. 相似文献5.
Hunter R Underhill Chun Yuan James G Terry Haiying Chen Mark A Espeland Thomas S Hatsukami Tobias Saam Baocheng Chu Wei Yu Minako Oikawa Norihide Takaya Vasily L Yarnykh Robert Kraft J Jeffrey Carr Joseph Maldjian Rong Tang John R Crouse III 《Journal of cardiovascular magnetic resonance》2008,10(1):31
Objective
We sought to determine differences with cardiovascular magnetic resonance (CMR) in the morphology and composition of the carotid arteries between individuals with angiographically-defined obstructive coronary artery disease (CAD, ≥ 50% stenosis, cases) and those with angiographically normal coronaries (no lumen irregularities, controls).Methods and results
191 participants (50.3% female; 50.8% CAD cases) were imaged with a multi-sequence, carotid CMR protocol at 1.5T. For each segment of the carotid, lumen area, wall area, total vessel area (lumen area + wall area), mean wall thickness and the presence or absence of calcification and lipid-rich necrotic core were recorded bilaterally. In male CAD cases compared to male controls, the distal bulb had a significantly smaller lumen area (60.0 ± 3.1 vs. 79.7 ± 3.2 mm2, p < 0.001) and total vessel area (99.6 ± 4.0 vs. 119.8 ± 4.1 mm2; p < 0.001), and larger mean wall thickness (1.25 ± 0.03 vs. 1.11 ± 0.03 mm; p = 0.002). Similarly, the internal carotid had a smaller lumen area (37.5 ± 1.8 vs. 44.6 ± 1.8 mm2; p = 0.006) and smaller total vessel area (64.0 ± 2.3 vs. 70.9 ± 2.4 mm2; p = 0.04). These metrics were not significantly different between female groups in the distal bulb and internal carotid or for either gender in the common carotid. Male CAD cases had an increased prevalence of lipid-rich necrotic core (49.0% vs. 19.6%; p = 0.003), while calcification was more prevalent in both male (46.9% vs. 17.4%; p = 0.002) and female (33.3% vs. 14.6%; p = 0.031) CAD cases compared to controls.Conclusion
Males with obstructive CAD compared to male controls had carotid bulbs and internal carotid arteries with smaller total vessel and lumen areas, and an increased prevalence of lipid-rich necrotic core. Carotid calcification was related to CAD status in both males and females. Carotid CMR identifies distinct morphological and compositional differences in the carotid arteries between individuals with and without angiographically-defined obstructive CAD. 相似文献6.
Sébastien Roujol Murilo Foppa Tamer A Basha Mehmet Ak?akaya Kraig V Kissinger Beth Goddu Sophie Berg Reza Nezafat 《Journal of cardiovascular magnetic resonance》2014,16(1)
Background
To investigate the feasibility of accelerated electrocardiogram (ECG)-triggered contrast enhanced pulmonary vein magnetic resonance angiography (CE-PV MRA) with isotropic spatial resolution using compressed sensing (CS).Methods
Nineteen patients (59 ± 13 y, 11 M) referred for MR were scanned using the proposed accelerated free breathing ECG-triggered 3D CE-PV MRA sequence (FOV = 340 × 340 × 110 mm3, spatial resolution = 1.5 × 1.5 × 1.5 mm3, acquisition window = 140 ms at mid diastole and CS acceleration factor = 5) and a conventional first-pass breath-hold non ECG-triggered 3D CE-PV MRA sequence. CS data were reconstructed offline using low-dimensional-structure self-learning and thresholding reconstruction (LOST) CS reconstruction. Quantitative analysis of PV sharpness and subjective qualitative analysis of overall image quality were performed using a 4-point scale (1: poor; 4: excellent).Results
Quantitative PV sharpness was increased using the proposed approach (0.73 ± 0.09 vs. 0.51 ± 0.07 for the conventional CE-PV MRA protocol, p < 0.001). There were no significant differences in the subjective image quality scores between the techniques (3.32 ± 0.94 vs. 3.53 ± 0.77 using the proposed technique).Conclusions
CS-accelerated free-breathing ECG-triggered CE-PV MRA allows evaluation of PV anatomy with improved sharpness compared to conventional non-ECG gated first-pass CE-PV MRA. This technique may be a valuable alternative for patients in which the first pass CE-PV MRA fails due to inaccurate first pass timing or inability of the patient to perform a 20–25 seconds breath-hold. 相似文献7.
Anitha Varghese Michael S Yee Cheuk F Chan Lindsey A Crowe Niall G Keenan Desmond G Johnston Dudley J Pennell 《Journal of cardiovascular magnetic resonance》2009,11(1):24
Background
There is recent evidence suggesting that rosiglitazone increases death from cardiovascular causes. We investigated the direct effect of this drug on atheroma using 3D carotid cardiovascular magnetic resonance.Results
A randomized, placebo-controlled, double-blind study was performed to evaluate the effect of rosiglitazone treatment on carotid atherosclerosis in subjects with type 2 diabetes and coexisting vascular disease or hypertension. The primary endpoint of the study was the change from baseline to 52 weeks of carotid arterial wall volume, reflecting plaque burden, as measured by carotid cardiovascular magnetic resonance. Rosiglitazone or placebo was allocated to 28 and 29 patients respectively. Patients were managed to have equivalent glycemic control over the study period, but in fact the rosiglitazone group lowered their HbA1c by 0.88% relative to placebo (P < 0.001). Most patients received a statin or fibrate as lipid control medication (rosiglitazone 78%, controls 83%). Data are presented as mean ± SD. At baseline, the carotid arterial wall volume in the placebo group was 1146 ± 550 mm3 and in the rosiglitazone group was 1354 ± 532 mm3. After 52 weeks, the respective volumes were 1134 ± 523 mm3 and 1348 ± 531 mm3. These changes (-12.1 mm3 and -5.7 mm3 in the placebo and rosiglitazone groups, respectively) were not statistically significant between groups (P = 0.57).Conclusion
Treatment with rosiglitazone over 1 year had no effect on progression of carotid atheroma in patients with type 2 diabetes mellitus compared to placebo. 相似文献8.
Lars ?lgaard Bloch Anne Yoon Krogh Gr?ndal Hansen Steen Fjord Pedersen Jesper Langhoff Honge Won Yong Kim Esben S?vs? Szocska Hansen 《Journal of cardiovascular magnetic resonance》2014,16(1):22
Background
Atherothrombosis remains a major health problem in the western world, and carotid atherosclerosis is an important contributor to embolic ischemic strokes. It remains a clinical challenge to identify rupture-prone atherosclerotic plaques before clinical events occur. Inflammation, endothelial injury and angiogenesis are features of vulnerable plaques and may all be associated with plaque edema. Therefore, vessel wall edema, which can be detected by 2D T2-weighted cardiovascular magnetic resonance (CMR), may be used as a dynamic marker of disease activity in the atherosclerotic plaque. However, 2D imaging is limited by low spatial resolution in the slice-select direction compared to 3D imaging techniques. We sought to investigate the ability of novel 3D techniques to detect edema induced in porcine carotid arteries by acute balloon injury compared to conventional 2D T2-weighted black-blood CMR.Methods
Edema was induced unilaterally by balloon overstretch injury in the carotid artery of nine pigs. Between one to seven hours (average four hours) post injury, CMR was performed using 2D T2-weighted short-tau inversion recovery (T2-STIR), 3D volumetric isotropic turbo spin echo acquisition (VISTA) and 3D T2 prepared gradient-echo (T2prep-GE). The CMR images were compared in terms of signal-to-noise ratio (SNR) and contrast-to-noise (CNR) ratio. Furthermore, the presence of vessel wall injury was validated macroscopically by means of Evans Blue dye that only enters the injured vessel wall.Results
All three imaging sequences classified the carotid arteries correctly compared to Evans Blue and all sequences demonstrated a significant increase in SNR of the injured compared to the non-injured carotid vessel wall (T2-STIR, p = 0.002; VISTA, p = 0.004; and T2prep-GE, p = 0.003). There was no significant difference between sequences regarding SNR and CNR.Conclusion
The novel 3D imaging sequences VISTA and T2prep-GE perform comparably to conventional 2D T2-STIR in terms of detecting vessel wall edema. The improved spatial coverage of these 3D sequences may facilitate visualization of vessel wall edema to enable detection and monitoring of vulnerable carotid atherosclerotic plaques. 相似文献9.
Anderson Simas Frutuoso Fernando Diefenthaeler Marco Aurélio Vaz Cintia de la Rocha Freitas 《International Journal of Sports Physical Therapy》2016,11(1):34-43
Background
Different limb training demands and limb preference may determine anthropometric and muscle force inter-limb asymmetries in Rhythmic Gymnastics (RG) athletes.Purpose
The purpose of this study was to evaluate the influence of lateral preference of the lower extremity on anthropometric, range of motion, and isokinetic torque measurements of RG athletes.Study Design
Cross sectional studyMethods
Lower limb anthropometric measurements (girth, estimated anatomical cross-sectional area), hip, knee and ankle range of motion, flexor and extensor isokinetic torques (angular velocities = 60, 180, e 240 °·s−1) and bilateral asymmetry index were evaluated in 11 international level Rhythmic Gymnastics athletes (17.9 ± 4.0 years of age; 9.1 ± 5,1 years of experience; 26.8 ± 6.0 weekly training hours).Results
The preferred limb showed larger thigh girth and anatomical cross-sectional area, higher ankle dorsiflexor range of motion, higher hip flexor torque at 60 °·s−1 and higher plantarflexor torque at 180 °·s−1 compared to the non-preferred limb.Conclusions
The observed differences seem to be strictly related to lateral preference and rhythmic gymnastics training.Levels of Evidence
3 相似文献10.
11.
Christopher Nguyen Zhaoyang Fan Yibin Xie James Dawkins Eleni Tseliou Xiaoming Bi Behzad Sharif Rohan Dharmakumar Eduardo Marbán Debiao Li 《Journal of cardiovascular magnetic resonance》2014,16(1)
Background
Despite the established role of late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) in characterizing chronic myocardial infarction (MI), a significant portion of chronic MI patients are contraindicative for the use of contrast agents. One promising alternative contrast free technique is diffusion weighted CMR (dwCMR), which has been shown ex vivo to be sensitive to myocardial fibrosis. We used a recently developed in vivo dwCMR in chronic MI pigs to compare apparent diffusion coefficient (ADC) maps with LGE imaging for infarct characterization.Methods
In eleven mini pigs, chronic MI was induced by complete occlusion of the left anterior descending artery for 150 minutes. LGE, cine, and dwCMR imaging was performed 8 weeks post MI. ADC maps were derived from three orthogonal diffusion directions (b = 400 s/mm2) and one non-diffusion weighted image. Two semi-automatic infarct classification methods, threshold and full width half max (FWHM), were performed in both LGE and ADC maps. Regional wall motion (RWM) analysis was performed and compared to ADC maps to determine if any observed ADC change was significantly influenced by bulk motion.Results
ADC of chronic MI territories was significantly increased (threshold: 2.4 ± 0.3 μm2/ms, FWHM: 2.4 ± 0.2 μm2/ms) compared to remote myocardium (1.4 ± 0.3 μm2/ms). RWM was significantly reduced (threshold: 1.0 ± 0.4 mm, FWHM: 0.9 ± 0.4 mm) in infarcted regions delineated by ADC compared to remote myocardium (8.3 ± 0.1 mm). ADC-derived infarct volume and location had excellent agreement with LGE. Both LGE and ADC were in complete agreement when identifying transmural infarcts. Additionally, ADC was able to detect LGE-delineated infarcted segments with high sensitivity, specificity, PPV, and NPV. (threshold: 0.88, 0.93, 0.87, and 0.94, FWHM: 0.98, 0.97, 0.93, and 0.99, respectively).Conclusions
In vivo diffusion weighted CMR has potential as a contrast free alternative for LGE in characterizing chronic MI. 相似文献12.
Uyen Truong Brian Fonseca Jamie Dunning Shawna Burgett Craig Lanning D Dunbar Ivy Robin Shandas Kendall Hunter Alex J Barker 《Journal of cardiovascular magnetic resonance》2013,15(1):81
Background
Pulmonary arterial hypertension (PAH) is a devastating disease with significant morbidity and mortality. At the macroscopic level, disease progression is observed as a complex interplay between mean pulmonary artery pressure, pulmonary vascular resistance, pulmonary vascular stiffness, arterial size, and flow. Wall shear stress (WSS) is known to mediate or be dependent on a number of these factors. Given that WSS is known to promote architectural vessel remodeling, it is imperative that the changes of this factor be quantified in the presence of PAH.Methods
In this study, we analyzed phase contrast imaging of the right pulmonary artery derived from cardiovascular magnetic resonance to quantify the local, temporal and circumferentially averaged WSS of a PAH population and a pediatric control population. In addition, information about flow and relative area change were derived.Results
Although the normotensive and PAH shear waveform exhibited a WSS profile which is uniform in magnitude and direction along the vessel circumference at systole, time-averaged WSS (2.2 ± 1.6 vs. 6.6 ± 3.4 dynes/cm2, P = 0.018) and systolic WSS (8.2 ± 5.0 v. 20.0 ± 9.1 dynes/cm2, P = 0.018) was significantly depressed in the PAH population as compared to the controls. BSA-indexed PA diameter was significantly larger in the PAH population (1.5 ± 0.4 vs. 0.7 ± 0.1 cm/m2, P = 0.003).Conclusions
In the presence of preserved flow rates through a large PAH pulmonary artery, WSS is significantly decreased. This may have implications for proximal pulmonary artery remodeling and cellular function in the progression of PAH. 相似文献13.
Ercan Kocakoc Ayse Ahsen Bakan Orhan Kursat Poyrazoglu Adile Ferda Dagli Yeliz Gul Mehtap Cicekci Ibrahim Halil Bahcecioglu 《Medical principles and practice》2015,24(6):522-526
Objective
To examine the effectiveness of apparent diffusion coefficient (ADC) values and to compare the reliability of different b-values in detecting and identifying significant liver fibrosis.Subjects and Methods
There were 44 patients with chronic viral hepatitis (CVH) in the study group and 30 healthy participants in the control group. Diffusion-weighted magnetic resonance imaging (DWI) was performed before the liver biopsy in patients with CVH. The values of ADC were measured with 3 different b-values (100, 600, 1,000 s/mm2). In addition, liver fibrosis was classified using the modified Ishak scoring system. Liver fibrosis stages and ADC values were compared using areas under the receiver-operating characteristic (ROC) curve.Results
The study group''s mean ADC value was not statistically significantly different from the control group''s mean ADC value at b = 100 s/mm2 (3.69 ± 0.5 × 10−3 vs. 3.7 ± 0.3 × 10−3 mm2/s) and b = 600 s/mm2 (2.40 ± 0.3 × 10−3 vs. 2.5 ± 0.5 × 10−3 mm2/s). However, the study group''s mean ADC value (0.99 ± 0.3 × 10−3 mm2/s) was significantly lower than that of the control group (1.2 ± 0.1 × 10−3 mm2/s) at b = 1,000 s/mm2. With b = 1,000 s/mm2 and the cutoff ADC value of 0.0011 mm2/s for the diagnosis of liver fibrosis, the mean area under the ROC curve was 0.702 ± 0.07 (p = 0.0015). For b = 1,000 s/mm2 and the cutoff ADC value of 0.0011 mm2/s to diagnose significant liver fibrosis (Ishak score = 3), the mean area under the ROC curve was 0.759 ± 0.07 (p = 0.0001).Conclusion
Measurement of ADC values by DWI was effective in detecting liver fibrosis and accurately identifying significant liver fibrosis when a b-value of 1,000 s/mm2 was used.Key Words: Diffusion-weighted imaging, Hepatitis, Fibrosis, Liver 相似文献14.
Rodolfo A. Dellagrana Fernando Diefenthaeler Felipe P. Carpes Sara G. Hernandez Wagner de Campos 《International Journal of Sports Physical Therapy》2015,10(4):514-519
Purpose/Background
Strength asymmetries are related to knee injuries and such injuries are frequently observed among runners. The purpose of this study was to examine whether long‐distance runners have symmetric performance during knee isokinetic testing at two angular velocities.Methods
Twenty‐three healthy and well‐trained male long‐distance runners performed open‐chain isokinetic trials for assessment of concentric quadriceps and hamstrings contractions at velocities of 60 °·s‐1 and 240 °·s‐1. Data were compared between the lower limbs at different velocities.Results
Peak torque and total work were similar between the limbs. Asymmetry was observed for knee flexor power at 240 °·s‐1 (237 ± 45 W and 205 ± 53 W, in the preferred and non‐preferred limb, respectively). Asymmetry indexes for flexor power were different between the velocities tested (13.1% and 2.21% for 240 °·s‐1 and 60 °·s‐1, respectively).Conclusion
A limb asymmetry was observed among runners for knee flexor power, mainly at higher angular velocities (240 °·s‐1). In addition, H/Q ratios were observed to be contraction velocity dependent.Level of Evidence
3 相似文献15.
Florian von Knobelsdorff-Brenkenhoff Valeriy Tkachenko Lukas Winter Jan Rieger Christof Thalhammer Fabian Hezel Andreas Graessl Matthias A Dieringer Thoralf Niendorf Jeanette Schulz-Menger 《Journal of cardiovascular magnetic resonance》2013,15(1):23
Background
Functional and morphologic assessment of the right ventricle (RV) is of clinical importance. Cardiovascular magnetic resonance (CMR) at 1.5T has become gold standard for RV chamber quantification and assessment of even small wall motion abnormalities, but tissue analysis is still hampered by limited spatial resolution. CMR at 7T promises increased resolution, but is technically challenging. We examined the feasibility of cine imaging at 7T to assess the RV.Methods
Nine healthy volunteers underwent CMR at 7T using a 16-element TX/RX coil and acoustic cardiac gating. 1.5T served as gold standard. At 1.5T, steady-state free-precession (SSFP) cine imaging with voxel size (1.2x1.2x6) mm3 was used; at 7T, fast gradient echo (FGRE) with voxel size (1.2x1.2x6) mm3 and (1.3x1.3x4) mm3 were applied. RV dimensions (RVEDV, RVESV), RV mass (RVM) and RV function (RVEF) were quantified in transverse slices. Overall image quality, image contrast and image homogeneity were assessed in transverse and sagittal views.Results
All scans provided diagnostic image quality. Overall image quality and image contrast of transverse RV views were rated equally for SSFP at 1.5T and FGRE at 7T with voxel size (1.3x1.3x4)mm3. FGRE at 7T provided significantly lower image homogeneity compared to SSFP at 1.5T. RVEDV, RVESV, RVEF and RVM did not differ significantly and agreed close between SSFP at 1.5T and FGRE at 7T (p=0.5850; p=0.5462; p=0.2789; p=0.0743). FGRE at 7T with voxel size (1.3x1.3x4) mm3 tended to overestimate RV volumes compared to SSFP at 1.5T (mean difference of RVEDV 8.2±9.3ml) and to FGRE at 7T with voxel size (1.2x1.2x6) mm3 (mean difference of RVEDV 9.3±8.6ml).Conclusions
FGRE cine imaging of the RV at 7T was feasible and provided good image quality. RV dimensions and function were comparable to SSFP at 1.5T as gold standard. 相似文献16.
Giovanni Biglino Jennifer A Steeden Catriona Baker Silvia Schievano Andrew M Taylor Kim H Parker Vivek Muthurangu 《Journal of cardiovascular magnetic resonance》2012,14(1):57
Background
Wave intensity analysis, traditionally derived from pressure and velocity data, can be formulated using velocity and area. Flow-velocity and area can both be derived from high-resolution phase-contrast cardiovascular magnetic resonance (PC-CMR). In this study, very high temporal resolution PC-CMR data is processed using an integrated and semi-automatic technique to derive wave intensity.Methods
Wave intensity was derived in terms of area and velocity changes. These data were directly derived from PC-CMR using a breath-hold spiral sequence accelerated with sensitivity encoding (SENSE). Image processing was integrated in a plug-in for the DICOM viewer OsiriX, including calculations of wave speed and wave intensity. Ascending and descending aortic data from 15 healthy volunteers (30 ± 6 years) data were used to test the method for feasibility, and intra- and inter-observer variability. Ascending aortic data were also compared with results from 15 patients with coronary heart disease (61 ± 13 years) to assess the clinical usefulness of the method.Results
Rapid image acquisition (11 s breath-hold) and image processing was feasible in all volunteers. Wave speed was physiological (5.8 ± 1.3 m/s ascending aorta, 5.0 ± 0.7 m/s descending aorta) and the wave intensity pattern was consistent with traditionally formulated wave intensity. Wave speed, peak forward compression wave in early systole and peak forward expansion wave in late systole at both locations exhibited overall good intra- and inter-observer variability. Patients with coronary heart disease had higher wave speed (p <0.0001), and lower forward compression wave (p <0.0001) and forward expansion wave (p <0.0005) peaks. This difference is likely related to the older age of the patients’ cohort, indicating stiffer aortas, as well as compromised ventricular function due to their underlying condition.Conclusion
A non-invasive, semi-automated and reproducible method for performing wave intensity analysis is presented. Its application is facilitated by the use of a very high temporal resolution spiral sequence. A formulation of wave intensity based on area change has also been proposed, involving no assumptions about the cross-sectional shape of the vessel. 相似文献17.
Hui Xue Peter Kellman Gina LaRocca Andrew E Arai Michael S Hansen 《Journal of cardiovascular magnetic resonance》2013,15(1):102
Background
Cine cardiovascular magnetic resonance (CMR) is challenging in patients who cannot perform repeated breath holds. Real-time, free-breathing acquisition is an alternative, but image quality is typically inferior. There is a clinical need for techniques that achieve similar image quality to the segmented cine using a free breathing acquisition. Previously, high quality retrospectively gated cine images have been reconstructed from real-time acquisitions using parallel imaging and motion correction. These methods had limited clinical applicability due to lengthy acquisitions and volumetric measurements obtained with such methods have not previously been evaluated systematically.Methods
This study introduces a new retrospective reconstruction scheme for real-time cine imaging which aims to shorten the required acquisition. A real-time acquisition of 16-20s per acquired slice was inputted into a retrospective cine reconstruction algorithm, which employed non-rigid registration to remove respiratory motion and SPIRiT non-linear reconstruction with temporal regularization to fill in missing data. The algorithm was used to reconstruct cine loops with high spatial (1.3-1.8 × 1.8-2.1 mm2) and temporal resolution (retrospectively gated, 30 cardiac phases, temporal resolution 34.3 ± 9.1 ms). Validation was performed in 15 healthy volunteers using two different acquisition resolutions (256 × 144/192 × 128 matrix sizes). For each subject, 9 to 12 short axis and 3 long axis slices were imaged with both segmented and real-time acquisitions. The retrospectively reconstructed real-time cine images were compared to a traditional segmented breath-held acquisition in terms of image quality scores. Image quality scoring was performed by two experts using a scale between 1 and 5 (poor to good). For every subject, LAX and three SAX slices were selected and reviewed in the random order. The reviewers were blinded to the reconstruction approach and acquisition protocols and scores were given to segmented and retrospective cine series. Volumetric measurements of cardiac function were also compared by manually tracing the myocardium for segmented and retrospective cines.Results
Mean image quality scores were similar for short axis and long axis views for both tested resolutions. Short axis scores were 4.52/4.31 (high/low matrix sizes) for breath-hold vs. 4.54/4.56 for real-time (paired t-test, P = 0.756/0.011). Long axis scores were 4.09/4.37 vs. 3.99/4.29 (P = 0.475/0.463). Mean ejection fraction was 60.8/61.4 for breath-held acquisitions vs. 60.3/60.3 for real-time acquisitions (P = 0.439/0.093). No significant differences were seen in end-diastolic volume (P = 0.460/0.268) but there was a trend towards a small overestimation of end-systolic volume of 2.0/2.5 ml, which did not reach statistical significance (P = 0.052/0.083).Conclusions
Real-time free breathing CMR can be used to obtain high quality retrospectively gated cine images in 16-20s per slice. Volumetric measurements and image quality scores were similar in images from breath-held segmented and free breathing, real-time acquisitions. Further speedup of image reconstruction is still needed. 相似文献18.
Shih-Pin Chen Yen-Feng Wang Po-Hsun Huang Chin-Wen Chi Jong-Ling Fuh Shuu-Jiun Wang 《The journal of headache and pain》2014,15(1):82
Background
The pathophysiology of reversible cerebral vasoconstriction syndrome (RCVS) remains elusive. Endothelial dysfunction might play a role, but direct evidence is lacking. This study aimed to explore whether patients with RCVS have a reduced level of circulating circulating endothelial progenitor cells (EPCs) to repair the dysfunctional endothelial vasomotor control.Methods
We prospectively recruited 24 patients with RCVS within one month of disease onset and 24 healthy age- and sex-matched controls. Flow cytometry was used to quantify the numbers of circulating EPCs, defined as KDR+CD133+, CD34+CD133+, and CD34+KDR+ double-positive mononuclear cells. The Lindegaard index, an index of vasoconstriction, was calculated by measuring the mean flow velocity of middle cerebral arteries and distal extracranial internal carotid arteries via color-coded sonography on the same day as blood drawing. A Lindegaard index of 2 was chosen as the cutoff value for significant vasoconstriction of middle cerebral arteries based on our previous study.Results
Patients with RCVS had a reduced number of CD34+KDR+ cells (0.009 ± 0.006% vs. 0.014 ± 0.010%, p = 0.031) but not KDR+CD133+ cells or CD34+CD133+ EPCs, in comparison with controls. The number of CD34+KDR+ cells was inversely correlated with the Lindegaard index (rs = -0.418, p = 0.047). Of note, compared to controls, patients with a Lindegaard index > 2 (n = 13) had a reduced number of CD34+KDR+ cells (0.007 ± 0.005% vs. 0.014 ± 0.010%, p = 0.010), but those with a Lindegaard index ≤ 2 did not.Conclusions
Patients with RCVS had reduced circulating CD34+KDR+ EPCs, which were correlated with the severity of vasoconstriction. Endothelial dysfunction might contribute to the pathogenesis of RCVS. 相似文献19.
John Stirrat Martin Rajchl Lynn Bergin David J Patton Terry Peters James A White 《Journal of cardiovascular magnetic resonance》2014,16(1)
Background
The extent of surgical scarring in Tetralogy of Fallot (TOF) may be a marker of adverse outcomes and provide substrate for ventricular arrhythmia. In this study we evaluate the feasibility of high resolution three dimensional (3D) late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) for volumetric scar quantification in patients with surgically corrected TOF.Methods
Fifteen consecutive patients underwent 3D LGE imaging with 3 Tesla CMR using a whole-heart, respiratory-navigated technique. A novel, signal-histogram based segmentation technique was tested for the quantification and modeling of surgical scar. Total scar volume was compared to the gold standard manual expert segmentation. The feasibility of segmented scar fusion to matched coronary CMR data for volumetric display was explored.Results
Image quality sufficient for 3D scar segmentation was acquired in fourteen patients. Mean patient age was 32.2 ± 11.9 years (range 21 to 57 years) with mean right ventricle (RV) ejection fraction (EF) of 53.9 ± 9.2% and mean RV end diastolic volume of 117.0 ± 41.5 mL/m2. The mean total scar volume was 11.1 ± 8.2 mL using semi-automated 3D segmentation with excellent correlation to manual expert segmentation (r = 0.99, bias = 0.89 mL, 95% CI -1.66 to 3.44). The mean segmentation time was significantly reduced using the novel semi-automated segmentation technique (10.1 ± 2.6 versus 45.8 ± 12.6 minutes). Excellent intra-observer and good inter-observer reproducibility was observed.Conclusion
3D high resolution LGE imaging with semi-automated scar segmentation is clinically feasible among patients with surgically corrected TOF and shows excellent accuracy and reproducibility. This approach may offer a valuable clinical tool for risk prediction and procedural planning among this growing population. 相似文献20.
Robin Simpson Jennifer Keegan David Firmin 《Journal of cardiovascular magnetic resonance》2013,15(1):34