首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The incidence of anastomotic leakage in colonic surgery is approximately 10%. We evaluated a technique of laser-fibrinogen reinforcement to strengthen experimental colonic anastomoses. The technique consisted of the topical application of indocyanine green dye-enhanced fibrinogen to the serosal surface of two-layer inverting anastomoses, followed by exposure with an 808-nm diode laser. In the 28 rabbits used for this study, mean bursting pressure at time 0 was 108 +/- 13 mm Hg in the group receiving anastomoses with sutures alone and 173 +/- 20 mm Hg in the group for which the sutured anastomosis was reinforced with laser-fibrinogen. The difference in bursting pressures between the two groups was statistically significant at time 0. However, at 1, 3, 5, and 7 days, the anastomosis became stronger in both groups and the difference in strength was reduced; the sutured group had more exceptionally weak (less than 110 mm Hg) bonds than the group treated by laser. Thus, laser-fibrinogen reinforcement significantly enhances the early strength of sutured colonic anastomoses. This technique may reduce the incidence of leakage during the first postoperative week and the associated complications in a clinical setting.  相似文献   

2.
BACKGROUND AND OBJECTIVES: To improve minimally invasive direct coronary artery bypass surgery (MID-CAB), new techniques of vascular anastomosis that are faster and more reliable need to be developed. STUDY DESIGN/MATERIALS AND METHODS: Common carotids in a canine model were transected and an end-to-end anastomosis was performed by using one of four techniques (1) continuous 6-0 polypropylene closure (suture; n=6), (2) vascular clip (VCS; n=6), laser welding using 50% albumin solder with (3) a 1.32-micro laser (1.32las; n=6), and (4) a 1.9-micro diode laser (1.9las; n=4). Times for anastomosis (TA) were compared between groups by t-test. Pressures at which anastomosis failed (leak point pressure, LPP) were determined and compared by analysis of variance. RESULTS: TA was faster for 1.32las and 1.9las at 8.4+/-0.7 and 7.8+/-0.3 min, respectively, when compared with suture at 13.8+/-1.0 min (P=0.001, confidence interval [CI]-8.1, -2.6 for 1.32las and CI -8.9, -3.1 for 1.9las). There was no statistical difference between VCS (8.3+/-3.3 min) and any other group (P > 0.17). LPPs (mm Hg) were similar for all groups: 350+/-37 for 1.32las, 280+/-31 for 1.9las, 347+/-46 for suture, and 358+/-53 for VCS, P=0.68. CONCLUSIONS: In this study, laser welding using 50% human albumin solder resulted in faster anastomotic times. Anastomoses were equivalent to conventional sutured anastomoses in failing at similar pressures. Laser welding using human albumin solder may be advantageous in improving coronary anastomoses during MID-CAB, but long-term anastomotic strength and histologic evaluation need to be investigated.  相似文献   

3.
PURPOSE: To compare running and interrupted suturing techniques for porcine vesicourethral anastomosis with regard to procedure time, histopathologic effects, and leakage. MATERIALS AND METHODS: Twelve domestic pigs were randomized to a running (N = 6) or an interrupted (N = 6) vesicourethral anastomosis with polyglycolic acid sutures. In each case, the bladder was drained for 7 days. A cystogram was performed immediately after completion of each anastomosis and on postoperative days 7 and 30. Animals were sacrificed on postoperative day 30, and the area of the anastomosis was excised en bloc for histopathologic evaluation. RESULTS: All procedures were completed laparoscopically. The mean operative time for continuous and interrupted suturing were 27.5 and 36.8 minutes, respectively (P = 0.3324). A significant learning curve was noted for both anastomoses, with operative times decreasing with experience in both groups. There was no difference in anastomotic leakage. Histopathology examination revealed more muscle-layer fibrosis in the interrupted- suture group than in the continuous-suture group, with a mean score of 2.17 and 1.67, respectively (P = 0.0325). CONCLUSIONS: Both continuous and interrupted vesicourethral anastomoses are feasible. In this in-vivo porcine comparison, there was no difference with respect to procedure time or anastomotic leakage. However, histopathologic grading demonstrated greater muscle fibrosis in the interrupted-suture group.  相似文献   

4.
OBJECTIVE: Stricture of the vesicourethral anastomosis remains a well-documented complication after radical retropubic prostatectomy. MATERIALS AND METHODS: We performed a retrospective study of 294 patients with prostate cancer who underwent radical retropubic prostatectomy. Possible correlations between anastomotic stricture formation, tumor stage, positive surgical margins, number of anastomotic sutures, bladder neck preservation, urine leakage, previous prostate surgery and/or intraoperative blood loss were examined. RESULTS: An anastomotic stricture was found in 18 cases (6%) requiring some kind of treatment. In 10 patients (56%), the bladder neck stricture occurred within 3 months after surgery, in 5 (28%) at 4-12 months after surgery and in 3 (16%) more than 12 months after surgery. Intraoperative blood loss (>1,000 ml) was found to be significantly correlated with urinary leakage (p < 0.001) and both correlated with anastomotic stricture formation (p < 0.005). CONCLUSION: Excessive intraoperative blood loss (>1,000 ml) and urine leakage was found to be significantly correlated to the formation of anastomotic stricture following radical retropubic prostatectomy.  相似文献   

5.
The frequency of anastomotic leaks after pancreatic resection is still significant. The majority of such leaks will heal without major clinical symptoms. In one fifth of patients, however, the sequelae of pancreatic leakage are serious and sometimes life-threatening. Management of such leaks ranges from local drainage to operative revision and completion pancreatectomy. The frequency of anastomotic leakage depends on a series of patient- and organ-specific risk factors. Surgical experience also plays a major role. Whether the prophylactic application of octreotide is able to reduce the frequency of pancreatic leaks is still a matter of debate. Leaks from direct bile duct sutures or biliodigestive anastomoses are rather seldom. Their clinical importance is limited. In case of a leak after direct bile duct anastomosis, endoscopic insertion of a stent seems to be the therapy of choice. Leaks from biliodigestive anastomoses which are diagnosed during the first 3 postoperative days should be treated by immediate operative revision. Late biliary leaks can be treated by local drainage. The results of bile duct surgery, too, are clearly dependent on the experience of the operating surgeon.  相似文献   

6.
The purpose of this study was to determine whether the characteristics of compression anastomoses created by a new device are comparable to existing stapler technology. A total of 18 pigs were studied, and each served as its own control using a 27-mm compression device and a 29-mm stapler. Anastomoses were randomized to proximal and distal positions along the rectum and were separated by 10 cm. Six nonsurvival pigs were sacrificed at zero time to failure test the anastomoses. Twelve pigs were sacrificed at 14 days. Failure pressures, circumferences, and radiographic leak rates were determined. Anastomotic tissue was processed for matrix metalloproteinase, collagen, and elastin levels. The compression anastomoses had higher mean failure pressures than stapled anastomoses at zero time (103 vs 29.9 mm Hg). At 2 weeks, there was no difference between failure pressures (256 vs 250 mm Hg). During burst testing, 3 of the compression anastomoses failed at the anastomosis at 2 weeks, whereas none of the stapled anastomoses failed. The mean anastomotic circumference of the compression anastomoses was narrower than the stapled anastomoses (9.63 vs 11.25 cm, P = .001). There were no clinical leaks or radiographic leaks by barium enema at 2 weeks. There was no difference between matrix metalloproteinase, collagen, or elastin content based on tissue analysis. There were dense adhesions to 7 of 12 (58.3%) of the stapled anastomoses, whereas only 1 of 12 (8.3%) of the compression anastomoses had flimsy adhesions. A new compression anastomosis technique using a nickel-titanium alloy may be an advance in technology by reducing leaks and eliminating foreign material in the anastomosis.  相似文献   

7.
Sutureless bowel anastomosis using Nd:YAG laser   总被引:5,自引:0,他引:5  
Small bowel anastomoses were performed without sutures by using the Nd:YAG laser to produce welded enterotomies. Optimal energy levels for contact and noncontact laser were determined. Anastomoses produced using five target energy levels between 100 and 500 J were examined. Short-term anastomotic strength of these enterotomies was measured 1 min after the welding. Bursting pressure of the laser welded enterotomies was compared to the bursting pressure of traditional two-layer, inverting, interrupted sutured bowel anastomoses. The overall mean bursting pressure of non-contact-welded enterotomies was 50.6 mmHg. Optimal laser settings determined in this initial phase were then used to produce anastomoses in rabbits which are recovered postoperatively for 1 or 2 weeks in order to examine long-term viability and integrity of the anastomoses. All chronic rabbit preparations recovered without complication. The mean bursting pressure was 200 mmHg, not significantly different from that of uncut bowel or two-layer sutured anastomosis.  相似文献   

8.
目的:评估在前列腺癌根治术中,以间断或连续缝合等2种不同的方法处理尿道膀胱吻合口后,远期尿道狭窄发生率的情况。方法:在2006~2010年间,国内3个临床中心共进行了549例开放或腹腔镜前列腺癌根治术。其中388例以问断缝合的方法处理膀胱尿道吻合口,161例以连续缝合的方法处理尿道膀胱吻合口,并评估术后吻合口狭窄发生率的情况。结果:45例(8.2%)患者m现术后尿道吻合口狭窄,发生的平均时间为术后4.1个月。在以间断缝合法处理吻合口的388例开放前列腺癌根治术患者中,10.1%(39例)的患者出现尿道狭窄;而在以连续吻合法处理的161例患者中,尿道狭窄发生率为3.7%(6例),其中75例开放前列腺癌根治术后发生率为2.7%(2例),86例腹腔镜前列腺癌根治术患者术后发生率为4.7%(4例)。结论:无论是以开放的或腹腔镜途径,用连续缝合法处理前列腺癌根治术中的尿道膀胱吻合口,术后吻合口狭窄的发生率低于间断缝合法。  相似文献   

9.
Summary Leakage from colonic anastomoses is a common cause of morbidity in patients recovering from bowel surgery. We evaluated a technique of laser-fibrinogen reinforcement to strengthen colonic anastomoses in a canine model. After creation of eight single-layer interrupted suture anastomoses in six dogs, indocyanine green-dye-enhanced fibrinogen was topically applied to the serosal surface and exposed to 808 mm diode laser energy. Immediately following colonic anastomosis, the mean leakage pressure was 137±22 mm Hg in the group (n=8) using sutures alone and 326±67 mm Hg (P<0.001) in the group (n=8) after the sutured anastomosis was reinforced with lasered-fibrinogen. On histological examination, no evidence of thermal injury to the tissue edges was noted and a layer of fibrinogen bridged the anastomotic gap. Laser dye-enhanced fibrinogen reinforcement significantly enhances the strength of sutured colonic anastomoses without causing appreciable thermal injury to the host tissues.  相似文献   

10.
Factors affecting leakage following esophageal anastomosis   总被引:6,自引:0,他引:6  
Esophageal anastomotic leaks remain the most serious problem following extirpative procedures for esophageal carcinoma. We conducted a retrospective analysis of 352 patients with carcinoma in the thoracic esophagus who had undergone esophageal anastomosis following esophagectomy at the Kurume University Hospital between 1981 and 1990. Of these, 94 patients (27%) developed anastomotic leaks, and out of this subgroup, 21 (6%) died as a direct result of the leak. A further 20 patients (6%) underwent repair of the leak, after which they were able to tolerate oral intake. The anastomotic leak healed spontaneously in the other 53 patients (15%). The risk factors predisposing to leaks from esophageal anastomoses were determined as: (1) the anastomosis being performed via a retrosternal or subcutaneous route as opposed to an intrathoracic route, (2) the use of colonic interposition as opposed to a gastric pedicle, (3) performing a manual anastomosis as opposed to a mechanical anastomosis, and (4) employing an end-to-end anastomosis, as opposed to an end-to-side anastomosis, using a mechanical method. By introducing an anastomotic stapling device, a microvascular technique, a staged operation based on the preoperative risk analysis, and improvement in pre- and postoperative management, the incidence of anastomotic leakage could be decreased from 35% to 14%, and that of consequent hospital mortality, from 9% to 2%.  相似文献   

11.
BACKGROUND: There is evolving interest in auditing and credentialling the performance of surgeons. The incidence of anastomotic leakage has been proposed as a measure of performance following colorectal surgery. The aim of this study was to evaluate the incidence and risk factors associated with anastomotic leakage in patients undergoing resections of the colon and rectum. METHODS: A prospective database was developed for all patients undergoing colorectal surgery. Anastomotic leakage was defined prior to the commencement of the study. A logistic regression analysis was performed to determine independent predictors of leakage. The variables analysed included age, sex, American Society of Anesthesiology (ASA) score, anatomical location, pathology, emergency surgery, type of anastomosis, a covering stoma and radiotherapy. Significance was defined as the probability of a type 1 error of < 5%. The results are presented as odds ratios (ORs) and 95% confidence intervals (95% CIs). RESULTS: There were 1598 patients who underwent 1639 anastomoses. Their mean age was 63 years, 34% of patients were ASA 3 or 4, and 16% of the operations were emergencies. Anastomotic leaks occurred in 2.4% (40/1639) of anastomoses. The leak rate for intraperitoneal anastomoses was 1.5% (19/1283) vs 6.6% for extraperitoneal anastomoses (21/316). Half of these leaks (20/40) were managed with re-operation or percutaneous drainage procedures. Ultra-low anterior resections were associated with the highest leak rate (8%, 18/225). A logistic regression analysis identified a covering stoma (P = 0.0001, OR 5.078, 95% CI 2.527-10.23) and diverticular disease (P = 0.037, OR 2.304, 95% CI 1.053-5.042) as independent predictors of a leak. CONCLUSIONS: Within this surgical unit, the incidence of leaks from intraabdominal anastomoses was relatively low. However, leaks in patients undergoing extraperitoneal anastomoses continue to be a major cause of morbidity and mortality.  相似文献   

12.
BACKGROUND AND OBJECTIVES: Esophagogastric anastomotic leaks complicate 5% to 20% of esophagectomies for esophageal cancer and are responsible for approximately one-third of perioperative deaths. Poor gastric emptying is a predisposing factor for anastomotic leakage. An animal experiment was used to test the hypothesis that a pyloric drainage procedure (pyloromyotomy) would have a positive effect on esophagogastric anastomotic healing. METHODS: In 40 rats single-layer esophagogastric anastomoses were constructed with interrupted 7-0 polypropylene sutures. A pyloromyotomy was done in the experimental group (20 rats) but not in the control group (20 rats). Rats were sacrificed on the 7th postoperative day and their anastomoses were excised, mounted in a tensiometer, and distracted at 10 mm/min to measure breaking strength. After that, the hydroxyproline concentration (an indicator of wound collagen) of the anastomotic tissue was measured. RESULTS: There were no anastomotic leaks. The mean (and standard deviation) breaking strength of the esophagogastric anastomosis was 3.96 (1.14) N in the pyloromyotomy rats and 4.11 (0.75) N in the control rats (p = 0.64). The mean (and SD) hydroxyproline concentration in esophagogastric anastomotic tissue was 368.6 (31.5) nmol/mg in the pyloromyotomy rats and 376.6 (31.3) nmol/mg in the control rats (p = 0.77). CONCLUSION: Pyloric drainage (pyloromyotomy) did not have any effect on esophagogastric anastomotic wound healing in this rat model.  相似文献   

13.
This study compared the healing of laser-welded and sutured canine femoral arteriovenous anastomoses. Arteriovenous fistulas 2 cm in length were created bilaterally in the femoral vessels of 10 dogs and were studied at 1 (n = 2), 2 (n = 2), 4 (n = 3), and 8 (n = 3) weeks. In each animal, one anastomosis (control) was closed with running 6-0 polypropylene sutures, and the contralateral anastomosis (experimental) was sealed with an argon laser (0.5 watt, 4 minutes of exposure, 1830 J/cm2/1 cm length of anastomosis). At removal all experimental anastomoses were patent without hematomas, aneurysms, or luminal narrowing. Histologic examination at 4 weeks revealed that laser-welded anastomoses had less inflammatory response and almost normal collagen and elastin reorientation. At 8 weeks sutured anastomoses had significant intimal hyperplasia whereas laser repairs had normal luminal architecture. Tensile strength and collagen production, measured by the synthesis of hydroxyproline and the steady-state levels of type I and type III procollagen messenger ribonucleic acids, at the anastomoses and in adjacent vein and artery specimens were similar in sutured and laser-welded repairs at 2, 4, and 8 weeks. We conclude that argon laser welding of anastomoses is an acceptable alternative to suture techniques, with the advantage of improved healing without foreign body response and possible diminished intimal hyperplasia at the anastomotic line.  相似文献   

14.
OBJECTIVE: We determined if transrectal ultrasound (TRUS) is as reliable as cystography in detecting vesicourethral extravasates after radical retropubic prostatectomy (RRP). PATIENTS AND METHODS: Between October 2005 and February 2006 we prospectively investigated 100 consecutive patients undergoing RRP. The vesicourethral anastomosis was proven 6 days after operation by a combined investigation with TRUS and cystography. RESULTS: In the majority of patients (79%) the vesicourethral anastomosis was watertight on postoperative day 6 (POD) or showed minimal leakage (8%) so that the urinary catheter was removed. Different degrees of paravasates were detected in 21 patients. Because of small, moderate, or marked paravasations the indwelling catheter was removed on POD 9, 14, and 21 in 5, 3, and 5 patients, respectively. Every paravasate documented by cystography had been detected by TRUS before. Therefore, TRUS showed no false-negative result in detecting insufficient anastomosis. In two patients paraurethral fluid was detected by TRUS mimicking anastomotic paravasation, without confirmation by cystography. CONCLUSIONS: TRUS can safely replace cystography to detect anastomotic leakage after radical prostatectomy.  相似文献   

15.
This preliminary report describes formation of femoral arterio-venous fistulas (n = 10) in six dogs using a 1.32-μm wavelength Nd:YAG laser welding technique. Stay sutures (6-0 polypropylene) were placed at 5–7 mm intervals along the anastomoses for vessel apposition. Delivery of laser energy through a 400-μm diameter fiber optic was controlled by a new computer-based software system. At 3 mm distance above the anastomosis, energy fluences of 110–260 J/mm2/cm length of anastomosis were used for laser welding. One or two additional hemostatic sutures were required in seven of the ten anastomoses. Flow was maintained for 1–2 hours prior to tissue harvesting. No thrombosis or delayed anastomotic failures were observed after initial welding and repair. Histologic examination revealed good apposition and adherence between wall layers and a fibrinous coagulum at the intimal junctions. Mild thermal injury of the wall was present at some anastomoses. This early investigation suggests that a 1.32 μm Nd:YAG laser welding technique can successfully create large vessel arteriovenous fistulas in the canine. © 1994 Wiley-Liss, Inc.  相似文献   

16.
Two hundred and two consecutive patients having an anterior resection of the rectum were studied retrospectively to determine the usefulness of intraoperative anastomotic testing. Saline introduced via a rectal catheter was used to distend the rectum and any leaks demonstrated were oversewn. Of 119 stapled anastomoses there were two (1.7%) clinical leaks; in both cases intraoperative testing had been negative. Five patients (4.2%) had leaks demonstrated by intraluminal distension. These defects were rectified at the time of operation and no clinical sequelae followed, three patients having had a covering colostomy added. Eighty-three untested handsewn anastomoses were also reviewed; all had a postoperative recovery uncomplicated by a clinical leak. These results raise the question: does intraoperative anastomotic testing produce false positives and/or weaken the anastomosis? We believe that in the three patients who required the addition of a covering colostomy a clinical leak was avoided as a result of the intraoperative test. The technique is simple, effective and probably helps reduce leakage following colorectal anastomoses.  相似文献   

17.
BACKGROUND AND OBJECTIVES: Current laser-assisted end-to-end anastomoses are performed by irradiating the vessel wall from outside after additional fixation with three to six sutures. These sutures are needed to provide adequate approximation of the vessel stumps. We present a new laser soldering technique that is based on an intraluminal laser light source centered in a balloon catheter, and external application of a solder. This technique was applied in vivo in order to test its feasibility under clinical conditions. STUDY DESIGN/MATERIALS AND METHODS: Seven white pigs were treated with a total of fourteen end-to-end laser-anastomoses of their saphenous arteries having outer diameters of 2 mm. The vessels were stented over an intraluminal balloon catheter, which was maximally dilated and which allowed for a precise approximation of the vascular stumps. An 808 nm diode laser was coupled into a specially designed optical fiber producing a 360 degrees radiation ring inside the balloon catheter. An indocyanine green (ICG) doped liquid albumin solder was applied on the external surface of the vascular stumps. Laser soldering was achieved by irradiating with a 808 nm laser diode for 75 seconds. Tightness of the anastomoses was evaluated by clamping the artery distal to the anastomosis for 1 hour, and patency was tested over an observation period of 3 hours, during which the animals were heparinized. Thereafter, the anastomoses were harvested for histomorphological examination. RESULTS: All anastomoses remained patent over the entire observation period. Some leakage was observed in three anastomoses, which was explained by a deviation of the illumination fiber from the center of the balloon leading to an inhomogeneous irradiation of the vessel wall. Histology revealed perfect adaptation of the vascular stumps. A segment of denaturated vascular collagen was observed, that corresponded to the irradiated, solder-covered zone. CONCLUSION: Patent, maximally dilated and well adapted microvascular anastomoses could be obtained without the need of stay sutures. A well centered laser light source is indispensable for avoiding inhomogenous welding, thus causing leakage.  相似文献   

18.

Introduction

Colorectal anastomotic leak, a feared complication, results in significantly increased patient morbidity, mortality, and hospital resource utilization. The overall incidence of colorectal anastomotic leak is approximately 11 % with increasing rate the closer the anastomosis is to the anal verge. Because surgeons are unable to reliably predict which anastomosis would fail, most will construct a diverting ileostomy for low colorectal anastomosis to circumvent the devastating complications of anastomotic failure. Despite extensive investigations on technical considerations of anastomosis construction, anastomotic leaks continue to occur at an unacceptably high rate.

Discussion

In this review, we examine the major known risk factors and technical considerations that have been implicated as factors in leakage. Although surgical technique has evolved over the past several decades with the advent of newer surgical staplers, laparoscopy, and robotics, we have not witnessed a decrease in the incidence of colorectal anastomotic leaks suggesting that the fundamental pathogenesis of anastomotic leak remains unknown. Among the factors contributing to anastomotic healing, intestinal bacteria remains largely overlooked even though compelling evidence exist that intraluminal microbes could play a major role in pathogenesis of anastomotic leak. Further investigation focusing on intestinal microbes could be one such avenue for uncovering the elusive cause of colorectal anastomotic leak.  相似文献   

19.
The effect of preoperative irradiation on the healing of low colorectal anastomoses was studied experimentally. In 12 dogs in whom preoperative irradiation of 4,000 rads was given before low colorectal stapled anastomosis was performed, anastomotic leakage occurred in 66 percent. More than half of the anastomotic leaks were associated with either severe sepsis or death. In a matched group of control animals that underwent stapled anastomoses without irradiation, no anastomotic complications occurred. The clinical implications of this study are that stapled anastomoses in irradiated colon are at serious risk of anastomotic dehiscence and, therefore, should be protected with a proximal colostomy.  相似文献   

20.
Esophagogastric anastomoses: the value of fibrin glue in preventing leakage   总被引:2,自引:0,他引:2  
Disruption of an esophagogastric anastomosis can result in a high mortality despite aggressive treatment. The efficacy of fibrin "glue" to seal esophagogastric anastomoses was evaluated as a means of preventing this complication. A left thoracotomy was performed in 25 adult mongrel dogs. After esophagogastric resection, a standardized esophagogastrostomy was performed and eight interrupted sutures were used to completely close the posterior wall. The anterior wall was approximated with only three sutures, leaving four large holes between sutures. The dogs were then randomized into the control group (n = 14; no attempt to seal the leaks) or into the fibrin glue-treated group (n = 11). An average of 3.3 ml of glue was applied to the anterior wall of the anastomosis in the treated group. In the control group, 13 of 14 dogs (92.9%) died of anastomotic leak a median of 3 days after operation. In the fibrin glue-treated group, only four of 11 dogs (36.4%) died of anastomotic leaks (p less than 0.01). Dogs that survived were put to death at 14 days. Postmortem examination in all dogs revealed no deleterious effects or complications related to the glue. Postmortem examination of the one surviving control dog and the seven fibrin glue-treated dogs that did not die of sepsis revealed a healed anastomosis without abscess formation. We conclude that fibrin glue is effective in lessening the incidence of esophagogastric anastomotic leaks as employed in this experimental model.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号