real time three-dimensional transesophageal echocardiography (3D TEE) is a novel imaging technique whose full utility is still being evaluated. We present a case utilizing 3D TEE for percutaneous placement of a left atrial appendage occlusion device. This evolving technology has potential application in other cardiovascular interventional procedures.  相似文献   

7.
8.

Objectives

This study sought to evaluate the feasibility, safety, and efficacy of the Ultraseal device for left atrial appendage closure (LAAC) (Cardia, Eagan, Minnesota) in patients with nonvalvular atrial fibrillation at high bleeding risk.

Background

The Ultraseal device is a novel bulb-and-sail designed LAAC device, with an articulating joint enabling conformability to heterogeneous angles and shapes of appendage anatomy.

Methods

This was a multicenter study including consecutive patients undergoing LAAC with the Ultraseal device at 15 Canadian and European sites. Periprocedural and follow-up events were systematically collected, and transesophageal echocardiography at 45 to 180 days post-procedure was routinely performed in all centers but 3.

Results

A total of 126 patients (mean age 75 ± 8 years; mean CHA2DS2-VASc score 5 ± 2; mean HAS-BLED score 4 ± 1) were included. The device was successfully implanted in 97% of patients. A major periprocedural adverse event occurred in 3 (2.4%) patients (clinically relevant pericardial effusion [n = 1], stroke [n = 1], device embolization [n = 1]). Ninety percent of patients were discharged on single or dual antiplatelet therapy. Follow-up transesophageal echocardiography was available in 89 (73%) patients, with no cases of large (>5 mm) residual leak and 5 (5.6%) cases of device-related thrombosis (all successfully treated with anticoagulation therapy). At a median follow-up of 6 (interquartile range: 3 to 10) months, the rates of stroke and transient ischemic attack were 0.8% and 0.8%, respectively, with no systemic emboli. None of the events occurred in patients with device-related thrombosis.

Conclusions

In this initial multicenter experience, LAAC with the Ultraseal device was associated with a high implant success rate and a very low incidence of periprocedural complications. There were no late device-related clinical events and promising efficacy results were observed regarding thromboembolic prevention at midterm follow-up. Larger studies are further warranted to confirm the long-term safety and efficacy of this novel device.  相似文献   

9.
10.
11.
12.
13.
14.
15.
16.
17.
Incomplete Endothelialization of Left Atrial Appendage . We describe the case of a 74‐year‐old man with Rendu Osler Weber syndrome affected by permanent atrial fibrillation, who underwent percutaneous placement of a 24‐mm Watchman left atrial appendage system. After anticoagulation therapy dismissal, he had a transient ischemic attack (TIA). Therefore he underwent surgical removal of the device, ablation of atrial fibrillation with Maze IV procedure and biatrial reduction. Very interestingly, no significant endothelialization of the device was observed 10 months after implantation. In conclusion, this case is important because, to our knowledge, it is the first finding of Watchman device with lack of endothelialization. (J Cardiovasc Electrophysiol, Vol. 23, pp. 1384‐1385, December 2012)  相似文献   

18.
Introduction: For patients undergoing catheter ablation of atrial fibrillation (AF), left atrial size is a predictor of recurrence of AF during follow-up. For this reason, major clinical trials have used a left atrial diameter (LAD) of more than 5.0 or 5.5 cm, assessed by echocardiography, as an exclusion criterion for patients deemed candidates for ablation of AF. However, whether LAD accurately reflects true left atrial size has not been systematically investigated. Therefore, the purpose of this study was to test the hypothesis that LAD, measured by echocardiography, accurately correlates to left atrial volume measured by computed tomography (CT).
Methods and Results: We included 50 patients (mean age 56 ± 12 years, five female) with symptomatic AF (40% paroxysmal, 60% persistent), referred for catheter ablation. In each patient, transthoracic echocardiography was performed. Additionally, all patients underwent CT using a 64-slice CT scanner. Left atrial volume was calculated by manually tracing left atrial area on each CT cross-sectional image. Patients had a mean LAD measured by echocardiography of 4.5 ± 0.7 cm, ranging from 2.9 to 5.7 cm. Left atrial volume measured by CT ranged from 67 mL to 270 mL with a mean value of 146 ± 49 mL. A poor correlation was noted between LAD and left atrial volume, r = 0.49 (P < 0.001).
Conclusion: LAD measured by echocardiography correlates poorly with left atrial volume measured by CT in patients with AF. As a result, selecting patients with AF for treatment with catheter ablation should not be based on an echocardiographic-derived LAD alone.  相似文献   

19.
20.