首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Loeffler endocarditis is a complication of hypereosinophilic syndrome resulting from eosinophilic infiltration of heart tissue. We report a case of Loeffler endocarditis in which three‐dimensional transthoracic and transesophageal echocardiography provided additional information to what was found by two‐dimensional transthoracic echocardiography alone. Our case illustrates the usefulness of combined two‐ and three‐dimensional echocardiography in the assessment of Loeffler endocarditis. In addition, a summary of the features of hypereosinophilic syndrome and Loeffler endocarditis is provided in tabular form.  相似文献   

2.
Ventricular septal rupture is a serious complication following acute myocardial infarctions and is associated with a significant mortality rate. Classically, two‐dimensional transthoracic echocardiography has been used to diagnose this complication and visualize its location. Two‐dimensional transesophageal echocardiography has supplemented the transthoracic approach by providing more accurate assessment of the defect size and in guiding closure both percutaneously and intraoperatively. This modality, however, is limited to two‐dimensional views only, and a greater breadth of information is instead available through the use of three‐dimensional transesophageal echocardiography. We present a series of 11 patients in which live/real time three‐dimensional transesophageal echocardiography offered incremental benefits over two‐dimensional imaging alone.  相似文献   

3.
Aorta to pulmonary artery fistula is an uncommon and potentially fatal condition. This case is of a 48‐year‐old Caucasian male with congestive heart failure and multiple aortic valve replacement surgeries who presented with an acquired ascending aortic aneurysm to pulmonary artery fistula diagnosed using two‐dimensional transthoracic echocardiography via nonstandard imaging windows. Three‐dimensional transthoracic echocardiography using live/real time three‐dimensional color Doppler was used to assess the size of the opening of the fistula, providing additional value. This patient was surgically managed and is doing well 8 months postoperation.  相似文献   

4.
We describe a 77‐year‐old female with hypertrophic cardiomyopathy in whom live/real time three‐dimensional transesophageal echocardiography (3DTEE) provided incremental value over two‐dimensional transthoracic and transesophageal echocardiography (2DTTE, 2DTEE) and three‐dimensional transthoracic echocardiography (3DTTE) in making a more comprehensive assessment and a more confident diagnosis of caseous mitral annular calcification. 3DTEE revealed a portion of the mass to consist of small, multiple, highly echogenic discrete band‐like and punctate areas within a relatively much less echogenic stroma and surrounded by a well defined highly echogenic border. This appearance correlated with the pathological findings of calcific granules/strands located in a liquefied or semiliquefied interior providing a typical toothpaste like appearance. The highly echogenic outer border represented the residual outer portion or rim of the calcific mass which did not undergo liquefaction. These findings on 3DTEE which correlated with the toothpaste like appearance seen at surgery were not visualized on 2DTTE, 2DTEE, and 3DTTE. (Echocardiography 2010;27:1147‐1150)  相似文献   

5.
We present a case of an adult with metastatic carcinoid heart disease, in whom live/real time three‐dimensional transthoracic echocardiography provided incremental value over two‐dimensional transthoracic echocardiography in assessing involvement of the aortic valve.  相似文献   

6.
We report a young patient with post traumatic acquired thoracic aortic coarctation in whom three‐dimensional transthoracic echocardiography (3DTTE) demonstrated incremental value over two‐dimensional transthoracic echocardiography (2DTTE). 3DTTE showed (1) en face views of the obstruction site that showed a markedly narrowed, roughly circular orifice measuring 0.33 cm2 in area, (2) echogenic tissue encroaching on the graft lumen consistent with fibrosis/thrombus, and (3) no graft protrusion into the aortic lumen, only hypermobility of the medial portion of the graft. These important findings were not detected by 2DTTE. (Echocardiography 2010;27:470‐472)  相似文献   

7.
Echocardiography has emerged as an essential tool to guide targeted, transcatheter biopsy of cardiac masses. Options for imaging include transthoracic or transesophageal echocardiography and intracardiac echocardiography, with appropriate use being dictated by specific patient characteristics and institutional experience. The authors present a case of three‐dimensional (3‐D) transesophageal echocardiography‐guided transcatheter biopsy of a right ventricular mass and review the current use of echocardiography to guide these procedures.  相似文献   

8.
We describe a case of hypertrophic cardiomyopathy with mid‐left ventricular obstruction and apical aneurysm containing thrombi where live/real time three‐dimensional transthoracic echocardiography provided incremental value over two‐dimensional echocardiography in assessing the findings.  相似文献   

9.
The usefulness of two‐dimensional transthoracic echocardiography (2DTTE) in the assessment of right heart compression and dysfunction produced by pectus excavatum chest wall deformity has been well described in the literature by several investigators. However, there is a paucity of reports describing incremental value of live/real time three‐dimensional transthoracic echocardiography (3DTTE) over the two‐dimensional technique in the evaluation of right heart function in these patients. We present a severe case of pectus excavatum chest wall deformity in a young male, in whom 3DTTE provided incremental value over standard 2DTTE in assessing compression of the right heart before surgery and marked improvement in right heart function parameters following surgical repair. In addition, an updated summary of salient features of this deformity, including 2D and 3DTTE findings as well as right heart echocardiographic parameters by both 2D and 3DTTE in normal/healthy subjects summarized from the literature have been provided in a tabular form for comparison.  相似文献   

10.
The mitral valve aneurysm is a rare complication of infective endocarditis involving mitral or aortic valve. The perforation of the mitral valve aneurysm can lead to significant mitral regurgitation (MR) or thromboembolism, which can cause sudden hemodynamic deterioration. We describe here a case of healed infective endocarditis of the aortic valve with ruptured mitral valve aneurysm that led to severe MR. The aneurysm of the anterior mitral leaflet was diagnosed by two‐dimensional transthoracic echocardiography. In this case, three‐dimensional transthoracic echocardiography demonstrated the detailed morphology of mitral valve aneurysm which resulted in successful surgical repair of the aneurysm.  相似文献   

11.
We describe the value of live/real time three‐dimensional transthoracic echocardiography (3DTTE) over two‐dimensional transthoracic echocardiography (2DTTE) in the assessment of inferior vena cava (IVC) and hepatic vein (HV) obstruction in a patient with sickle cell disease. 3DTTE provided additional information when compared to 2DTTE by (1) identifying the obstructing lesion as a likely thrombus, (2) by providing assessment of anatomical severity of IVC lumen obstruction since the thrombus could be visualized en face also, and (3) identifying an area of increased mobility of a portion of the thrombus suggesting greater risk of embolization. (Echocardiography 2010;27:594‐596)  相似文献   

12.
Endomyocardial fibrosis is a form of restrictive cardiomyopathy mainly affecting poor children and young adults in geographically restricted areas of Latin America, Africa, and Southeast Asia. The pathophysiological hallmark of the disease is focal or diffuse endocardial thickening involving mainly the inflow, the apices, and the subvalvular region leading to valvular regurgitation, diastolic dysfunction and obliteration of the ventricular apex. Advanced right‐sided disease has slow flow of blood through chambers with propensity of thrombus formation especially in the right atria. Although two‐dimensional transthoracic echocardiography remains the cornerstone for the diagnosis of this disease, the case presented here shows how three‐dimensional transthoracic echocardiography can add substantial information regarding the region of involvement of the right ventricle as well as the various characteristics of the right atrial thrombus.  相似文献   

13.
We demonstrate the incremental value of live/real time three‐dimensional transthoracic echocardiography (3DTTE) over the two‐dimensional modality in the identification of all three cusps of the pulmonary valve in patients in whom only two leaflets could be detected by the latter technique. This was because of the ability of 3DTTE to view the cusps enface permitting assessment of relationship to one another and the surrounding cardiac structures. In addition, 3DTTE showed not only the potential errors that can occur in pulmonary valve cusp identification when the two‐dimensional modality is used alone but also how some of these errors can be avoided by paying attention to the surrounding structures.  相似文献   

14.
We report an elderly patient presenting with a stroke and also hemolytic anemia secondary to mitral and tricuspid valve repair 3 years earlier, in whom two‐dimensional transesophageal echocardiography (2DTEE) suspected a fistula into the pulmonary artery (APAF) from the posterior wall of the aortic arch. For further assessment, two‐dimensional transthoracic echocardiography (2DTTE) and live/real time three‐dimensional transthoracic echocardiography (3DTTE) were performed. 2DTTE showed findings similar to 2DTEE. Color Doppler guided continuous‐wave Doppler showed continuous flow throughout the cardiac cycle with systolic preponderance across the fistula with a small peak pressure gradient of 22 mmHg. Sequential systematic cropping of the 3D datasets obtained from 3DTTE confirmed that the flow signals originated from the posterior wall of the aortic arch and not the lumen. Thus, 3DTTE served to increase the confidence level that the fistula most likely originated from a vasum vasi in the wall of the aortic arch. To our knowledge, this type of fistula has not been reported previously. Fistulas from the aortic lumen to the pulmonary artery are also rare and so far only 24 cases have been reported in the literature. These are also reviewed by us.  相似文献   

15.
Background: Carcinoid heart disease (CHD) is a rare cause of valvular heart disease and carries a poor prognosis. CHD has a unique morphology and echocardiographic features that predominantly involve right‐sided valvular structures. The diagnosis of CHD is usually made by two‐dimensional transthoracic echocardiography (TTE). With the superior spatial resolution of real time three‐dimensional transesophageal echocardiography (3DTEE), structural changes that occur in patients with CHD‐associated valvular heart disease can be examined in greater detail. We undertook this study to examine the incremental value of 3DTEE in the diagnosis of CHD. Methods: A total of four patients with CHD underwent TTE, transesophageal echocardiography (TEE), and 3DTEE as part of their routine clinical evaluation. Results: TTE and TEE for all four patients revealed thickened, fibrosed, retracted, and malcoapted tricuspid leaflets with wide‐open tricuspid valve regurgitation. 3DTEE en face imaging of the tricuspid valve demonstrated the characteristic morphologic features of CHD more clearly in all four patients. Conclusions: 3DTEE provides substantial incremental value over TTE in the assessment of characteristic CHD pathology and thus enhances the echocardiographic diagnosis of CHD. (Echocardiography 2010;27:1098‐1105)  相似文献   

16.
In a man presenting to the emergency room with dyspnea and atypical chest pain irradiated among the scapulae, with new‐onset diffuse negative T‐waves on the ECG, the first clinical and diagnostic hypothesis was pulmonary embolism (PE). However, computed tomography (CT) performed in emergency was negative for PE, showing instead a marked defect in right ventricle (RV) filling. For this reason, echocardiography was performed to better investigate the nature of the space‐occupying lesion, and several echocardiographic modalities were used (two‐dimensional transthoracic and transesophageal echocardiography and three‐dimensional [3D] transthoracic echocardiography). They revealed the presence of a mass attached to the apex of the RV, partially obstructing the inflow and outflow tracts. Cardiac magnetic resonance imaging was also performed, confirming the findings of 3D echocardiography. After that, several other diagnostic imaging techniques were used for disease staging, since the patient had a history of surgical excision of a malignant melanoma of the skin several years before. Whole‐body CT, soft tissue echography and positron emission tomography revealed the widespread diffusion of the primary tumor to distant organs. For this reason, we suspected that the RV mass could also be an intracardiac metastasis from malignant melanoma, and did not perform biopsy given the bad clinical conditions and the worse prognosis of the patient. However, he was entered in an experimental therapeutic protocol with Vemurafenib because he showed B‐RAF gene mutation at molecular gene analysis.  相似文献   

17.
We describe the use of a nonstandard left infraclavicular approach in making the diagnosis of an infected valved conduit with two‐dimensional transthoracic echocardiography. The patient was an adult with tetralogy of Fallot and pulmonary atresia who had undergone multiple surgical repair procedures. The initial diagnosis of infective endocarditis was made by transesophageal echocardiography. Both techniques demonstrated a single, large vegetation in the conduit. Live/real time three‐dimensional transthoracic echocardiography, on the other hand, provided further information by demonstrating several additional vegetations in the conduit and more comprehensively assessed their size by enabling measurement of their azimuthal dimensions and volumes. The patient was treated with antibiotics with complete resolution of the vegetations.  相似文献   

18.
A 2.5‐year‐old boy presented with frequent hospitalizations due to recurrent respiratory tract infections with dyspnea. A fibromuscular membrane dividing the left atrium with obstruction of left atrial inflow to the left ventricle was documented by two‐dimensional transthoracic echocardiography (2DTTE). Live/real time three‐dimensional transthoracic echocardiography (3DTTE) provided incremental value over 2DTTE by providing en face views of the 2 obstructing orifices in the membrane enabling accurate assessment of their position, shape and size. 3DTTE also showed clearly the location of the membrane superior and proximal to the left atrial appendage which was not well delineated by 2DTTE. In addition, 3DTTE demonstrated the full extent of the left atrial appendage and careful sequential cropping of the 3D dataset showed it to have 2 distinct lobes and no thrombus. These findings provided comprehensive assessment of the lesion and were helpful in surgical decision making and planning.  相似文献   

19.
Multi‐imaging modalities should be considered in patients with atrial septal defects (ASDs) in which the degree of right ventricular enlargement is not fully explained by the small size of ASD found on conventional transthoracic echocardiography. We report a case of crescent‐shaped superior sinus venosus ASD discriminated using real‐time three‐dimensional transesophageal echocardiography. MDCT confirmed its relationship with the superior vena cava and the absence of combined anomalies, such as the pulmonary venous return anomaly.  相似文献   

20.
Aorto‐atrial fistulas are rare, but important complications resulting from aortic valve infective endocarditis, aortic valve surgery, or aortic dissection. We hereby report a case of a 20‐year male, referred to us with infective endocarditis of the native aortic valve with severe aortic regurgitation and symptoms of heart failure. Detailed evaluation with two‐dimensional and three‐dimensional transthoracic echocardiography revealed aorto‐left atrial fistula secondary to the involvement of the mitral–aortic intervalvular fibrosa (MAIVF) region. The patient underwent successful removal of the vegetations, closure of the defect along with aortic valve replacement, and mitral valve repair.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏