PurposeTo analyze in vivo ablation properties of microwave ablation antennae in tumor-bearing human livers by performing retrospective analysis of ablation zones following treatment with two microwave ablation systems.Materials and MethodsPercutaneous microwave ablations performed in the liver between February 2011 and February 2013 with use of the AMICA and Certus PR ablation antennae were included. Immediate postablation computed tomography images were evaluated retrospectively for ablation length, diameter, and volume. Ablation length, diameter, and volume indices were calculated and compared between in vivo results and references provided from each device manufacturer. The two microwave antenna models were then also compared versus each other.ResultsTwenty-five ablations were performed in 20 patients with the AMICA antenna, and 11 ablations were performed in eight patients with the Certus PR antenna. The AMICA and Certus PR antennae showed significant differences in ablation length (P = .013 and P = .009), diameter (P = .001 and P = .009), and volume (P = .003 and P = .009). The AMICA ablation indices were significantly higher than the Certus PR ablation indices in length (P = .026) and volume (P = .002), but there was no significant difference in ablation diameter indices (P = .110).ConclusionsIn vivo ablation indices of human tumors are significantly smaller than reference ex vivo ablation indices, and there are significant differences in ablation indices and sphericity between devices.  相似文献   

2.

Purpose

To identify and compare predictors of local tumor progression (LTP)-free survival (LTPFS) after radiofrequency (RF) ablation and microwave (MW) ablation of colorectal liver metastases (CLMs).

Materials and Methods

This is a retrospective review of CLMs ablated from November 2009 to April 2015 (110 patients). Margins were measured on contrast-enhanced computed tomography (CT) 6 weeks after ablation. Clinical and technical predictors of LTPFS were assessed using a competing risk model adjusted for clustering.

Results

Technique effectiveness (complete ablation) was 93% (79/85) for RF ablation and 97% (58/60) for MW ablation (P = .47). The median follow-up period was significantly longer for RF ablation than for MW ablation (56 months vs. 29 months) (P < .001). There was no difference in the local tumor progression (LTP) rates between RF ablation and MW ablation (P = 0.84). Significant predictors of shorter LTPFS for RF ablation on univariate analysis were ablation margins 5 mm or smaller (P < .001) (hazard ratio [HR]: 14.6; 95% confidence interval [CI]: 5.2–40.9) and perivascular tumors (P = .021) (HR: 2.2; 95% CI: 1.1–4.3); both retained significance on multivariate analysis. Significant predictors of shorter LTPFS on univariate analysis for MW ablation were ablation margins 5 mm or smaller (P < .001) (subhazard ratio: 11.6; 95% CI: 3.1–42.7) and no history of prior liver resection (P < .013) (HR: 3.2; 95%: 1.3–7.8); both retained significance on multivariate analysis. There was no LTP for tumors ablated with margins over 10 mm (median LTPFS: not reached). Perivascular tumors were not predictive for MW ablation (P = .43).

Conclusions

Regardless of the thermal ablation modality used, margins larger than 5 mm are critical for local tumor control, with no LTP noted for margins over 10 mm. Unlike RF ablation, the efficiency of MW ablation was not affected for perivascular tumors.  相似文献   

3.

Purpose

To evaluate local control and survival after image-guided ablation of adrenal gland metastases.

Materials and Methods

Image-guided ablations of adrenal metastases measuring < 5 cm performed at 2 academic medical centers between July 2002 and June 2016 were analyzed. There were 51 procedures performed on 46 tumors (mean diameter 2.8 cm ± 1.1; range, 0.7–4.9 cm) in 38 patients (mean age 66 y; range, 41–80 y) with renal cell carcinoma (n = 17 patients; 45%), non–small cell lung cancer (n = 10 patients; 26%), and other primary malignancies (n = 11 patients; 29%). Treatment modalities included cryoablation (n = 30 procedures; 59%), radiofrequency ablation (n = 12 procedures; 24%) and microwave ablation (n = 9 procedures; 18%). Technical success, primary and secondary efficacy, local progression rate, local progression-free survival, and overall survival were assessed. Mean follow-up was 37 months (range, 2–128 months). Statistical analysis was performed with univariate Cox hazards regression and Kaplan-Meier analyses.

Results

Technical success, primary efficacy, and secondary efficacy were 96%, 72%, and 76%. Local progression rate during all follow-up was 25%. Local tumor progression-free survival at 1, 3, and 5 years was 82%, 69%, and 55%. Overall survival at 1, 3, and 5 years was 82%, 44%, and 34%. In 16 patients with isolated adrenal metastasis, median disease-free survival was 8 months; 4 patients had no evidence of disease during follow-up. Lung cancer was associated with decreased survival (hazard ratio 4.41, P = .002).

Conclusions

Image-guided ablation can achieve local control for adrenal metastases < 5 cm.  相似文献   

4.
5.

Objective

To determine in vivo efficacy of radiofrequency ablation (RFA) in porcine liver by using 15-gauge Octopus® (15-G Octopus®) electrodes to create a large coagulation.

Materials and Methods

A total of 18 coagulations were created by using a 180-W generator and 15-G Octopus® electrodes during laparotomy, performed in 14 pigs. Coagulation necrosis was created in the pig livers by the use of one of three RFA protocols: 1) group A, monopolar RFA using a 15-G Octopus® electrode with a 5-mm inter-electrode distance (n = 4); 2) group B, monopolar RFA using a 15-G Octopus® electrode with a 10-mm inter-electrode distance (n = 6); and 3) group C, switching monopolar RFA using two 15-G Octopus® electrodes (n = 8). The energy efficiency, shape, maximum and minimum diameters (Dmx and Dmi), and the volume of the coagulation volume were measured in each group. The Summary statistics were obtained and Mann-Whitney test was were performed.

Results

The mean ablated volume of each group was 49.23 cm3 in A, 64.11 cm3 in B, and 72.35 cm3 in C. The mean Dmx and Dmi values were 5.68 cm and 4.58 cm in A and 5.97 cm and 4.97 cm in B, respectively. In group C, the mean diameters of Dmx and Dmi were 6.80 cm and 5.11 cm, respectively. The mean ratios of Dmi/Dmx were 1.25, 1.20, and 1.35 in groups A, B, and C, respectively. There was one animal death during the RFA procedure, the cause of which could not be subsequently determined. However, there were no other significant, procedure-related complications during the seven-hour-delayed CT scans.

Conclusion

RFA procedures using 15-G Octopus® electrodes are useful and safe for creating a large ablation in a single electrode model as well as in the multiple electrodes model.  相似文献   

6.
7.

Purpose

To evaluate the feasibility of self-expanding metal stent (SEMS) placement and fluorescence microendoscopic monitoring for determination of fibroblast cell proliferation after stent placement in an esophageal mouse model.

Materials and Methods

Twenty fibroblast-specific protein (FSP)-1 green fluorescent protein (GFP) transgenic mice were analyzed. Ten mice (Group A) underwent SEMS placement, and fluoroscopic and fluorescence microendoscopic images were obtained biweekly until 8 weeks thereafter. Ten healthy mice (Group B) were used for control esophageal values.

Results

SEMS placement was technically successful in all mice. The relative average number of fibroblast GFP cells and the intensities of GFP signals in Group A were significantly higher than in Group B after stent placement. The proliferative cellular response, including granulation tissue, epithelial layer, submucosal fibrosis, and connective tissue, was increased in Group A. FSP-1-positive cells were more prominent in Group A than in Group B.

Conclusions

SEMS placement was feasible and safe in an esophageal mouse model, and proliferative cellular response caused by fibroblast cell proliferation after stent placement was longitudinally monitored using a noninvasive fluorescence microendoscopic technique. The results have implications for the understanding of proliferative cellular response after stent placement in real-life patients and provide initial insights into new clinical therapeutic strategies for restenosis.  相似文献   

8.
The purpose of this study was to investigate differences in change of size and CT value between local recurrences and tumor-free areas after CT-guided radiofrequency ablation (RFA) of hepatic metastases during follow-up by means of dedicated software for automatic evaluation of hepatic lesions. Thirty-two patients with 54 liver metastases from breast or colorectal cancer underwent triphasic contrast-enhanced multidetector-row computed tomography (MDCT) to evaluate hepatic metastatic spread and localization before CT-guided RFA and for follow-up after intervention. Sixteen of these patients (65.1 ± 10.3 years) with 30 metastases stayed tumor-free (group 1), while the other group (n = 16 with 24 metastases; 62.0 ± 13.8 years) suffered from local recurrent disease (group 2). Applying an automated software tool (SyngoCT Oncology; Siemens Healthcare, Forchheim, Germany), size parameters (volume, RECIST, WHO) and attenuation were measured within the lesions before, 1 day after, and 28 days after RFA treatment. The natural logarithm (ln) of the quotient of the volume 1 day versus 28 days after RFA treament was computed: lnQ1//28/0volume. Analogously, ln ratios of RECIST, WHO, and attenuation were computed and statistically evaluated by repeated-measures ANOVA. One lesion in group 2 was excluded from further evaluation due to automated missegmentation. Statistically significant differences between the two groups were observed with respect to initial volume, RECIST, and WHO (p < 0.05). Furthermore, ln ratios corresponding to volume, RECIST, and WHO differed significantly between the two groups. Attenuation evaluations showed no significant differences, but there was a trend toward attenuation assessment for the parameter lnQ28/0attenuation (p = 0.0527), showing higher values for group 1 (–0.4 ± 0.3) compared to group 2 (–0.2 ± 0.2). In conclusion, hepatic metastases and their zone of coagulation necrosis after RFA differed significantly between tumor-free and local-recurrent ablation zones with respect to the corresponding size parameters. A new parameter (lnQ1//28/0volume/RECIST/WHO/attenuation) was introduced, which appears to be of prognostic value at early follow-up CT.  相似文献   

9.

Purpose

To assess safety and renal-function outcomes after microwave (MW) ablation of localized stage T1 renal cell carcinoma (RCC).

Materials and Methods

A retrospective review was conducted of 38 patients (28 men; mean age, 69 y; range, 51–88 y) who underwent computed tomography (CT)–guided MW ablation for stage T1N0M0 RCC. Baseline and follow-up renal function surrogates including creatinine level and estimated glomerular filtration rate (eGFR) were statistically compared. Peri- and postoperative complication rates, technical success, and treatment response were also assessed.

Results

A total of 44 biopsy-proven stage T1N0M0 RCCs measuring 1.2–6.9 cm (mean, 2.5 cm) were treated, and renal function was measured 1 mo after treatment. Mean eGFRs were 60 mL/min/1.73 m2 at baseline and 59 mL/min/1.73 m2 at 1 month after ablation. At 1-year and last follow-ups, the means of difference were 3.3% (95% confidence interval, ?4.4 to 4.3; P = .99) and 3.3% (95% confidence interval, ?4.3 to 4.8; P = .91), respectively. The 2-years freedom from eGFR decrease to < 60 mL/min/1.73 m2 was 2% (P = .91). Among the 5 patients (13%) with preexisting stage 4 chronic kidney disease (CKD; eGFR < 30 mL/min/1.73 m2) before ablation, there was no significant postablative onset of decline or CKD upstaging (P = .001). There were no major complications, and 5 patients (13%) had small asymptomatic perinephric hematomas (Society of Interventional Radiology minor complication, class A/B) that were managed conservatively.

Conclusions

At 2-year follow-up, CT-guided percutaneous MW ablation is safe and well-tolerated and achieves nephron preservation similar to existing ablative modalities.  相似文献   

10.
11.
12.
13.
14.

Purpose

To evaluate whether changes in volumetric iodine concentration (VIC) could serve as a suitable predictor of therapeutic response to microwave (MW) ablation in a rabbit intrahepatic VX2 tumor model.

Materials and Methods

Sixteen intrahepatic VX2 tumors were transplanted in 8 New Zealand White rabbits treated with MW ablation. Contrast-enhanced dual-energy CT scans were obtained at baseline and follow-up. Therapeutic response assessment by modified Response Evaluation Criteria In Solid Tumors (mRECIST), Choi criteria, and VIC changes was performed. An intraclass correlation coefficient (ICC) was used to characterize consistency of assessment results among the criteria used. Technical success was evaluated with explant pathologic findings as a reference. Correlations between technical success and variations in diameter, CT density, and VIC were analyzed.

Results

Disease control was observed in 4, 8, and 10 of the 16 tumors per mRECIST, Choi criteria, and VIC changes, respectively. VIC exhibited strong consistency (ICC = 0.807, P < .0001) with Choi criteria. According to explant pathology, technical success was achieved in 10 of the 16 tumors. There was a moderate correlation between VIC changes and technical success (r = 0.532, P = .034), and no correlation was found between technical success and variations in diameter or CT density.

Conclusions

Compared with mRECIST and Choi criteria, dual-energy CT–derived VIC allowed for better prediction of therapeutic response after MW ablation and could provide a potential imaging biomarker of tumor response to MW ablation in patients with hepatocellular carcinoma.  相似文献   

15.
16.
The purpose of this study was to investigate the optimal setting for radiofrequency (RF) ablation combined with direct electrical current (DC) ablation in ex vivo bovine liver. An electrical circuit combining a commercially available RF ablation system with DC was developed. The negative electrode of a rectifier that provides DC was connected to a 3-cm multitined expandable RF probe. A 100-mH inductor was used to prevent electrical leakage from the RF generator. DC was applied for 15 min and followed by RF ablation in freshly excised bovine livers. Electric current was measured by an ammeter. Coagulation volume, ablation duration, and mean amperage were assessed for various DC voltages (no DC, 2.2, 4.5, and 9.0 V) and different RF ablation protocols (stepwise increase from 40 to 80 W, 40 W fixed, and 80 W fixed). Results were compared using Kruskal–Wallis and Mann–Whitney U test. Applying DC with 4.5 or 9.0 V, in combination with 40 W fixed or a stepwise increase of RF energy, resulted in significantly increased zone of ablation size compared with 2.2 V or no DC (P = 0.009). At 4.5 V DC, the stepwise increase of RF energy resulted in the same necrosis size as a 40 W fixed protocol (26.6 ± 3.9 vs. 26.5 ± 4.0 ml), but ablation duration was significantly decreased (296 ± 85 s vs. 423 ± 104 s; P = 0.028). Mean amperage was significantly lower at 4.5 V compared with 9.0 V (P = 0.028). Combining a stepwise increase of RF energy with a DC voltage of 4.5 V is most appropriate to increase coagulation volume and to minimize procedure time.  相似文献   

17.
Calciphylaxis is a serious and potentially life-threatening disorder characterized by medial calcification of arterioles leading to subcutaneous ischemia and skin necrosis. It is most commonly seen in patients with end-stage renal disease or shortly after renal transplantation. We report an unusual case of calciphylaxis occurring 16 years after renal transplantation in a 48-year-old female with a failing graft, along with histological and striking radiological findings.  相似文献   

18.

Purpose

To develop a scoring system that stratifies complexity of percutaneous ablation of renal tumors.

Materials and Methods

Analysis was performed of 36 consecutive patients (mean age, 64 y; range, 30–89 y) who underwent CT-guided microwave (MW) ablation of 45 renal tumors (mean tumor diameter, 2.4 cm; range, 1.2–4.0 cm). Technical success and effectiveness were determined based on intraprocedural and follow-up imaging studies. The RENAL score and the proposed percutaneous renal ablation complexity (P-RAC) score were calculated for each tumor.

Results

Technical success was 93.3% (n = 42). Biopsy of 38 of 45 renal tumors revealed 23 renal cell carcinomas. Median follow-up period was 9.7 months (range, 2.9–46.8 months). There were no tumor recurrences. One major complication, ureteropelvic junction stricture, occurred (2.6%). The P-RAC score was found to differ statistically from the RENAL score (t = 3.754, df = 44, P = .001). A positive correlation was found between the P-RAC score and number of antenna insertions (r = .378, n = 45, P = .011) and procedure duration (r = .328, n = 45, P = .028). No correlation was found between the RENAL score and number of MW antenna insertions (r = .110, n = 45, P = .472) or procedure duration (r = .263, n = 45, P = .081). Hydrodissection was significantly more common in the P-RAC high-complexity category than in low-complexity category (χ2 = 12.073, df = 2, P = .002).

Conclusions

The P-RAC score may be useful in stratifying percutaneous renal ablation complexity. Further studies with larger sample sizes are necessary to validate the P-RAC score and to determine if it can predict risk of complications.  相似文献   

19.

Purpose

This study was designed to analyze the effect of two different ablation modes (“temperature control” and “power control”) of a microwave system on procedural outcome in porcine kidneys in vivo.

Methods

A commercially available microwave system (Avecure Microwave Generator; MedWaves, San Diego, CA) was used. The system offers the possibility to ablate with two different ablation modes: temperature control and power control. Thirty-two microwave ablations were performed in 16 kidneys of 8 pigs. In each animal, one kidney was ablated twice by applying temperature control (ablation duration set point at 60 s, ablation temperature set point at 96°C, automatic power set point; group I). The other kidney was ablated twice by applying power control (ablation duration set point at 60 s, ablation temperature set point at 96°C, ablation power set point at 24 W; group II). Procedural outcome was analyzed: (1) technical success (e.g., system failures, duration of the ablation cycle), and (2) ablation geometry (e.g., long axis diameter, short axis diameter, and circularity).

Results

System failures occurred in 0% in group I and 13% in group II. Duration of the ablation cycle was 60 ± 0 s in group I and 102 ± 21 s in group II. Long axis diameter was 20.3 ± 4.6 mm in group I and 19.8 ± 3.5 mm in group II (not significant (NS)). Short axis diameter was 10.3 ± 2 mm in group I and 10.5 ± 2.4 mm in group II (NS). Circularity was 0.5 ± 0.1 in group I and 0.5 ± 0.1 in group II (NS).

Conclusions

Microwave ablations performed with temperature control showed fewer system failures and were finished faster. Both ablation modes demonstrated no significant differences with respect to ablation geometry.  相似文献   

20.
The retention of foreign bodies after surgery is rare, but carries significant morbidity and mortality as well as financial and legal implications. Such retained items cause a foreign-body reaction, which in the case of cotton-based materials are called gossypibomas. We present the case of an 84-year-old woman with a pseudotumor secondary to a retained dressing gauze roll, presenting 5 months after resection of a gluteal sarcoma, which had raised concerns of local recurrence. We also outline the imaging modalities that may assist in diagnosis of a retained foreign body, and suggest the MRI “row of dots” sign as a useful radiological feature associated with gossypiboma. Awareness of the imaging appearances of retained foreign bodies allows the inclusion of this possibility in differential diagnosis of a mass in patients with a surgical history.  相似文献   