首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Twenty-three elbows in 17 rheumatoid arthritis patients have undergone unconstrained Souter-Strathclyde elbow replacements since March 1984. One patient developed a deep-wound infection, and 4 others had a temporary ulnar nerve paresis. At follow-up 3 (0.5-6) years postoperatively, there was a moderate improvement in the arc of movements: 25° in extension-flexion and 45° in forearm rotation. Pain relief was achieved in 20 cases. Three elbows required revision, two following recurrent dislocation and the other after a humeral fracture and component loosening.  相似文献   

2.
Mitral valve surgery after previous CABG with functioning IMA grafts   总被引:1,自引:0,他引:1  
Background. Mitral valve surgery after previous coronary artery bypass grafting presents a challenging problem for the cardiac surgeon. An injury to patent coronary artery bypass grafts, especially internal mammary artery grafts, during reoperation via a redo sternotomy, may be fatal. Therefore, a reliable alternative to the redo sternotomy is desirable to minimize potential injury to internal mammary artery grafts.

Methods. Between February 1987 and October 1998, we performed 59 consecutive mitral valve operations after previous coronary artery bypass grafting surgery (CABG). A total of 24 patients (41%) had functioning internal mammary artery (IMA) grafts and represent the population for this study. No patients were excluded for any reason. Of the 24 patients, 20 (83%) were men. Mean age was 66 ± 13 years (range 41 to 83 years) and the mean duration from CABG was 5.3 ± 3.6 years (range 0.1 to 12 years). Four (17%) had functioning bilateral internal mammary artery grafts. All had 3 to 4+ mitral regurgitation (MR) at the time of mitral valve surgery and the mean preoperative ejection fraction (EF) was 40% ± 14% (range 20% to 74 %).

Results. Twenty-one (88%) patients underwent mitral valve surgery through an anterolateral right thoracotomy and 3 (12%) through a redo sternotomy. Twenty-two (92%) patients, including the 3 patients in whom a redo sternotomy was used, had cannulation of the femoral artery and vein. Two patients required axillary artery cannulation. All 21 patients in whom the mitral valve was approached through a right thoracotomy underwent deep hypothermia (19.6° ± 2.1°C, range 14° to 25°C) without aortic clamping, with a mean duration of CPB of 138 ± 46 minutes (range 65 to 249 minutes). In 18 (75%), the MR was ischemic in origin and in 6 (25%) there was myxomatous degeneration. Nine (34%) required valve replacement and 15 (66%) underwent repair. There were no operative or hospital deaths and all patients were discharged to home or to a rehabilitation facility. There were 4 (17%) major complications. Two patients suffered respiratory failure requiring tracheotomy, 1 patient developed a perioperative MI requiring an intraaortic balloon pump and 1 developed heart block requiring a permanent pacemaker. There were no neurologic, peripheral vascular, bleeding, or wound complications.

Conclusions. Reoperative mitral valve surgery in the setting of functioning IMA grafts, even in the face of depressed LV function, can be done safely and with minimal morbidity.  相似文献   


3.
Osteotomy for kyphosis in ankylosing spondylitis   总被引:1,自引:0,他引:1  
Twenty-two patients suffering from progressive kyphosis due to ankylosing spondylitis underwent one or more lumbar osteotomies during 1957-1983. The primary thoracic kyphosis was 80° (45°-155°). The mean correction obtained by one level osteotomy was 44° (30°-60°).

The mean loss of correction after 3 years was 5°. The use of internal fixation reduced the loss of correction from 9° to 1°, also allowing ambulatory after-care and a shorter period of immobilization in plaster or jackets. We had no fatal and relatively few non-fatal complications; three cases of retrograde ejaculation were observed however. All the patients reported subjective respiratory improvement.  相似文献   

4.
Adult thalassemic patients have reduced bone mass due to disturbances in several different mechanisms affecting bone turnover. To determine if vitamin D deficiency contributes to the low bone mass of adult thalassemic subjects, we studied serum 25-OH-vitamin D levels in 90 patients (age ranging between 21 and 48 years) affected with thalassemia major (TM) and 35 (age 21–56 years) with thalassemia intermedia (TI).

TM patients had been receiving regular transfusions from the age of 2 years and had increased serum ferritin, glutamic oxalacetic transaminase, glutamic piruvic transaminase as well as low bone density (L1–L4 Z score −2.07 ± 0.2). TI patients did not receive transfusions, but their ferritin levels were increased as well (520.3 ± 138,1). 8 TM patients (10.1%) and 4 TI (11.4%) had serum 25-OH-vitamin D less than 10.4 ng/ml and were considered presenting an absolute deficiency of vitamin D. Mean 25-OH-vitamin D was significantly (P < 0.01) lower in both TM and TI patients (20.3 ± 0.7 ng/ml and 20.9 ± 2.3 ng/ml, respectively) than in 100 healthy control subjects of similar age (25.2 ± 1 ng/ml). 1,25-OH-vitamin D levels were in the normal–lower levels (45.15 ± 1.5 mg/dl), while 24 H urinary calcium was below the normal range (15.75 mg/dl). In TM patients, the 25-OH-vitamin D levels correlated negatively with age (P < 0.05) and with serum ferritin (P < 0.05). TM and TI patients with low 25-OH-vitamin D levels (<17.8 ng/ml) presented higher serum ferritin levels (P < 0.01) and higher PTH (P < 0.05) compared to those with normal vitamin D. Moreover, TM patients with low 25-OH-vitamin D levels were significantly older (P < 0.05) and had higher GPT (P < 0.05) than patients with normal vitamin D.

In conclusion, calcium metabolism is frequently impaired in adult thalassemic patients. An early and effective medical treatment should be taken in consideration by the clinician in order to improve the bone health in these patients.  相似文献   


5.
Background Recurrent dislocation in total hip replacement is difficult to treat and causes severe morbidity.

Patients and methods 12 patients suffering dislocations were reoperated with a socket wall addition device (anti-luxation ring) for the Lubinus SPII prosthesis, and were followed up after a mean of 4.5 (1-9) years with regard to redislocation, function and radiographic loos-ening.

Results 1 of the patients suffered a redislocation after almost 7 years of use. There was no loosening during the follow-up time. A Harris hip score of 87 (60-100), a health-related quality of life (EQ-5D) index of 0.8 (0.6-1.0) and total range of motion of 145° (125-165) indicate that the patients had a level of function comparable to that of age-matched hip surgery patients with no com-plications.

Interpretation The anti-luxation ring shows promising mid-term results and seems to provide an alternative to more extensive revision surgery for selected patients. ▪  相似文献   

6.
Background. This study was conducted to evaluate allograft aortic root replacement in the setting of complicated prosthetic valve endocarditis with extensive annular destruction.

Methods. From January 1990 through March 1996, 32 patients diagnosed with complicated prosthetic valve endocarditis underwent allograft root replacement. Mean age was 58.3 ± 13.2 years; 23 patients were men. Mean preoperative New York Heart Association functional class was 3.4. Staphylococcus epidermidis (50%) and Enterococcus faecalis (19%) were the predominant causative microorganisms. Annular abscesses were found in 26 patients (81%), aortic-mitral discontinuity in 14 patients (43%), and left ventricular-aortic discontinuity in 11 patients (34%). A cryopreserved allograft was used in 31 patients (97%) and a fresh antibiotic-treated allograft was used in 1 patient (3%). Mean aortic cross-clamp time was 150 ± 29 minutes. Mean duration of the postoperative antibiotic treatment was 38.5 ± 11.8 days.

Results. There were three operative deaths (9.4%); causes of death were multiorgan failure in 2 patients (6.2%) and low cardiac output in 1 patient (3.2%). Six patients (18%) had complete heart block (4 patients already before the operation), 3 patients (9.4%) had temporary respiratory insufficiency, and 1 patient (3.2%) needed temporary hemodialysis. Mean follow-up was 37.4 ± 22.4 months. Two late deaths occurred: 1 patient had recurrent endocarditis, leading to a false aneurysm, and died at reoperation; another patient died of lung cancer. Actuarial 5-year survival was 87.3% (70% confidence interval, 76.8% to 97.8%); actuarial 5-year freedom from recurrent endocarditis was 96.5% (70% confidence interval, 90.0% to 100%)

Conclusions. Allograft aortic root replacement is a valuable technique in the complex setting of prosthetic valve endocarditis with involvement of the periannular region. Mortality and morbidity are low.  相似文献   


7.
We compared the angle of trunk rotation (ATR) from scoliometer readings with Cobb angle measurements of the lateral deviation of the spine in 150 children referred to hospital for evaluation of scoliosis. the mean Cobb angle in thoracic curves was 16 °, in thoracolumbar curves 17° and in lumbar curves 20°. in thoracic curves and in right convex curves no patient with a Cobb angle of 25° or more had an ATR below 9°. in thoracolumbar and lumbar and in left convex curves, 7° ATR was occasionally associated with scoliosis of 25° or more. the correlation coefficient between the ATR and Cobb angle in right convex curves was 0.65 compared to 0.57 in left convex curves. We conclude that a criterion of 7° ATR for thoracic or right convex curves and one of 6° ATR for thoracolumbar and lumbar or left convex curves seem adequate for identification of patients with Cobb angles of 25° or more, which reduces the need for spinal radiography and follow-up outside the school screening programs.  相似文献   

8.
Objectives: Congenital cardiac malformations are usually corrected in the neonatal period or in early infancy. Corrective surgery may not always be definitive, especially in complex malformations. Long-term morbidity is influenced by reoperations and their risk. Methods: This study analyzes our single-center experience over more than 20 years in a selected group of patients. Data were gathered, with special focus on causes and incidence for reoperations, respectively. Results: Freedom from reoperation after 5, 10, and 15 years for each cardiac malformation was determined. The numbers describe in the following order patient years (y), number of patients (n), and freedom from reoperation at follow-up interval (%), respectively: atrial septal defect (15 864y, n=1198, 99±0/99±0/99±0), partial atrioventricular septal defect (2506y, n=234, 95±2/93±2/93±2), total anomalous pulmonary venous connection (742y, n=141, 93±1/91±0/91±0), complete atrioventricular septal defect (1715y, n=377, 81±3/76±3/72±4), tetralogy of Fallot <1 year (1503y, n=197, 94±4/85±1/74±3), transposition of great arteries (1459y, n=375, 88±2/83±4/73±7), interrupted aortic arch (IAA) (481y, n=98, 63±6/52±7/45±8), common arterial trunk (CAT) (599y, n=109, 64±6/24±6/11±5). Conclusions: In most congenital malformations surgical correction is definitive and the rate of reoperations is low. In complex anomalies, such as CAT and IAA, reoperations at long-term are more common. Analysis of such results and recognition of a sometimes inevitable operative morbidity helps to predict long-term outcome and influences the follow-up.  相似文献   

9.
From 1991 to 1997 we performed 20 tibialis posterior tendon-transfer operations in 17 patients with drop-foot, in 11 of peripheral neurogenic origin and in 6 because of neuromuscular disease. Postoperatively, all patients could walk without an ankle-foot orthosis. At follow-up after mean 2 (1-5) years, all patients had active dorsiflexion of the foot and toes, with a median active ankle dorsiflexion of 5° (-15-10°). The median active plantar flexion was 40° (10-45°), and the total range of movement was 40° (15-50°). At foi-low-up, the gait was good in 15 and improved in 2 of the 17 patients.  相似文献   

10.
Background and Methods. A National Institutes of Health-sponsored trial (1994 to 1998) randomized patients undergoing coronary artery bypass grafting that required three or more grafts to receive perfusion at either cold (20°C), tepid (32°C), or warm (37°C) temperature. The goal of the study was to evaluate morbidity, primarily neurologic dysfunction and secondarily hematologic factors. One thousand seven hundred seventy-seven patients were screened and 291 enrolled. Neurologic function was studied by a dedicated pool of blinded neurologists. A standard test battery termed the Mathew Scale using three subscales—cognitive function, elemental skills, and disability—was used to study central nervous system function. Hematologic function was assessed in 53 of the 291 patients with measurements of postoperative fibrinolytic potential.

Results. All preoperative and operative data were comparable between groups. A decrease in Mathew Scale was seen in 69% of patient from before operation to immediately after operation. However, between the early postoperative study and the 1-month follow-up, 48% of patients had returned to baseline. There was no difference noted across temperature groups in any neurologic parameter of function. In all, 55% of the group were at or above their preoperative level at 1 month. Forty-nine patients suspect for cerebrovascular accident had a computed tomographic scan, but only 13 (4.5%) had a documented cerebrovascular accident (4 patients in the warm, 3 in the tepid, and 6 patients in the cold group). Fibrinolytic changes correlated with perfusion temperature documented that fibrinolysis was most active at 37°C. Thus, increasing perfusate temperature increases fibrinolysis, which was associated with reoperation for bleeding in 4% warm group patients, 1% tepid, and 0% cold group patients (0.1 > p >0.05). No other perioperative complications were temperature related. There were 4 deaths (1.4%) (1 in the warm group, 2 in the tepid group, and 1 in the cold group).

Conclusions. (1) Persistent postoperative neurologic dysfunction at 1 month occurs in 36% of patients undergoing coronary artery bypass grafting and is not related to a cerebrovascular accident; 2) perfusion temperature has no relationship to neurologic function after bypass; and 3) fibrinolytic activity is greatest at warm temperatures.  相似文献   


11.
Objective: Patients with end stage cardiomyopathy frequently present with additional severe mitral regurgitation. We analyzed the outcome of mitral valve reconstruction in this high risk patient group. Methods: Sixty-six patients with significant mitral regurgitation and an ejection fraction (EF) below 30% (dilated CARDIOMYOPATHY=53, ischemic cardiomyopathy (ICM)=13) were retrospectively evaluated from 07/96 and 02/02. All received annuloplasty ring implantation and additional repair (n=4) if required. Mean follow-up was 28±18 months. Results: Mitral valve repair (MVR) was technically feasible in all patients. Intraoperative transesophageal echocardiography (TEE) revealed none (n=60) or only trivial (n=6) residual mitral regurgitation. Thirty day mortality was 6.1%. Actuarial survival after 1 and 5 years was 86±4 and 66±8%, respectively. During follow-up seven patients were transplanted due to lack of clinical improvement after 10±7 months (range 1–23). Echocardiography revealed a significant improvement in EF (25±10.5% pre-op, 34±15% post-op) and a slight decrease in left ventricular end-diastolic diameter (69±10 mm pre-op, 67±13 mm follow up). Patients were in NYHA functional -class 3 (median) preoperatively and in class 2 at long term-follow-up. Gender, left ventricular enddiastolic diameter, preoperative ejection fraction or type of surgical approach (sternotomy, right lateral minithoracotomy) had no significant influence on patient outcome. Patients with ICM or patients older than 60 years showed an increased risk for clinical events both early post-operatively and at long-term follow-up. Conclusion: MVR can be performed with low perioperative morbidity and mortality even in patients with advanced heart failure, modifying selection criteria for potential candidates may further improve long term outcome.  相似文献   

12.
Background. The ideal temperature for blood cardioplegia administration remains controversial.

Methods. Fifty-two patients who required elective myocardial revascularization were prospectively randomized to receive intermittent antegrade tepid (29°C; group T, 25 patients) or cold (4°C; group C, 27 patients) blood cardioplegia.

Results. The two cohorts were similar with respect to all preoperative and intraoperative variables. The mean septal temperature was higher in group T (T, 29.6° ± 1.1°C versus 17.5° ± 3.0°C; p < 0.0001). After reperfusion, group T exhibited significantly greater lactate and acid release despite similar levels of oxygen extraction (p < 0.05). The creatine kinase-MB isoenzyme release was significantly lower in group T (764 ± 89 versus 1,120 ± 141 U · h/L; p < 0.04). Hearts protected with tepid cardioplegia demonstrated significantly increased ejection fraction with volume loading, improvement in left ventricular function at 12 hours, and decreased need for postoperative inotropic support (p < 0.05). The frequency of ventricular defibrillation after cross-clamp removal was lower in this cohort (p < 0.05). There were no hospital deaths, and both groups had similar postoperative courses.

Conclusions. Intermittent antegrade tepid blood cardioplegia is a safe and efficacious method of myocardial protection and demonstrates advantages when compared with cold blood cardioplegia in elective myocardial revascularization.  相似文献   


13.
The Kapandji procedure was performed on 14 patients who presented with chronic pain at the distal radioulnar joint, limited forearm rotation or poor grip after an injury involving the distal radioulnar joint. Ten patients were able to resume their original occupation and leisure activities. Some complained of mild aching after heavy use. Postoperatively, grip strength on the affected side was, on average, 84 per cent that of the opposite side. Forearm rotation in the affected arm averaged 129 ° before operation and 170 ° afterwards, compared with 171 ° on the normal side, while wrist flexion-extension averaged 129 ° preoperatively, 126 ° postoperatively and 148 ° on the normal side.

Four patients had less satisfactory results because of pain and a feeling of insecurity due to an unstable proximal ulna. However, two of these had severe residual problems in relation to the initial forearm component of the injury, the symptoms from which were difficult to separate from the distal radioulnar injury.

Although the Kapandji procedure can yield excellent results, it is difficult to predict which patients will suffer from an unstable ulna.  相似文献   


14.
Aortic arch repair with right brachial artery perfusion   总被引:9,自引:0,他引:9  
Background. To determine the effectiveness of unilateral selective cerebral perfusion for aortic arch repair and to discuss possible modifications to enhance technical simplicity.

Methods. In the period between January 1996 and April 2001, 104 patients underwent aortic arch repair with the use of right brachial artery low flow (8 to 10 mL/kg per minute) antegrade selective cerebral perfusion under moderate hypothermia (26°C). Mean patient age was 52 ± 12 years. Sixty-four patients presented with Stanford type A aortic dissection, including 12 with acute dissection; 38 patients had aneurysmal dilatation of the ascending aorta and aortic arch; and 2 patients had isolated arch aneurysm. Ascending and partial arch replacement was performed in 50 patients; ascending and total arch replacement in 33 patients; ascending and descending arch replacement in 19 patients; and isolated arch replacement in 2 patients.

Results. Mean antegrade cerebral perfusion time was 39 ± 22 minutes. One patient with acute proximal dissection died because of cerebral complications. One other patient developed right hemiparesis, which resolved during the second postoperative month without sequela. Other than these 2 cases (1.9%), no other neurologic event was observed.

Conclusions. The technique of low flow antegrade selective cerebral perfusion through the right brachial artery may be used for a vast majority of aortic aneurysms and dissections requiring arch repair. This technique does not necessitate deep hypothermia, requires shorter cardiopulmonary bypass and operation times, has the advantage of simplicity, provides optimal vascular repair without time restraints and, in terms of clinical results, is as safe as other techniques for cerebral protection.  相似文献   


15.
Methods: In this prospective trial, 50 burn patients were randomised to be treated either with early tangential excision and skin grafting or by the application of honey dressings, with delayed skin grafting as necessary. The 25 patients in the tangential excision (TE) group had burns of 23±4%, 12% of which was full thickness. The honey treated patients (HT), (N=25), had burns of 24±4%, 13% of which was full thickness. Seventeen of the TE patients were operated upon on day 3, the remainder before day 6 post burn. Eleven of the HT patients eventually required skin grafting. Cosmetic and functional results were assessed at 3 months post discharge.

Results: In the TE group, the skin grafting take rate was 99±3%. In the HT group, the graft take rate was 74±18% (P<0.01). The mean percentage of blood volume replaced was 35±12% in TE patients vs. 21±15% in HT patients (P<0.01). Only one TE patient died due to status asthmaticus, while there were 3 deaths, all from sepsis, in the HT patients. At 3 month follow-up, 92% of the TE patients had good to excellent functional and cosmetic results vs. 55% in HT patients, 3 of whom had significant contractures.

Conclusion: Early tangential excision and skin grafting was clearly superior to expectant treatment using topical honey in patients with moderate burns in this randomised, prospective study performed at a General Hospital in the Indian subcontinent. The availability of suitable allogenic blood is a potential problem when TE is employed.  相似文献   


16.
Objective. The long-term durability and hemodynamics of stentless valves are largely unknown. Our aim was to prospectively investigate long-term hemodynamic function and clinical outcome after aortic valve replacement with the Biocor stentless aortic bioprosthesis. Patients and methods. Between October 1990 and November 2000 we inserted the Biocor stentless aortic valve in 112 patients (male/female: 38:74) with a mean age of 78.5 years (median 79.3, range 60–88). The predominant diagnosis was aortic stenosis in 86% of the patients. Concomitant coronary artery bypass surgery was performed in 31% of the patients. Average prosthetic valve size was 23.3±1.6 mm. All patients were followed in a prospective study with a mean follow-up of 66±33 months. The follow-up was 100% complete with a closing interval from October 1 to December 31, 2001. The observed actuarial survival of patients was compared to expected survival for an age- and gender-matched comparison population as calculated from Swedish life tables by Statistics Sweden. Relative survival rates were calculated annually for the patient population. Results. Early mortality was 7% (8/112). Late mortality was 38% (43/112). Actuarial survival at 5 and 9 years was 74±5% and 38±7%, respectively. Observed survival among patients was not different from the expected survival for the comparison population and calculation of relative survival rates indicates a ‘normalized’ survival pattern for the patient population. At 5 and 9 years the actuarial freedom from valve-related death was 94±3% and 86±6%; from cardiac death, 82±4% and 57±8%; from valve reoperation, 96±2% and 87±6%; from structural valve degeneration, 96±2% and 87±6%; from thromboembolism, 89±4% and 71±9%; and from endocarditis, 96±2% and 90±5%. At 9 years the transvalvular mean pressure difference for all valves was 7.3±1.3 mmHg (range 6–10 mmHg) measured with Doppler echocardiography. Aortic regurgitation progressed slowly over time in a few patients and necessitated reoperation in two patients. Conclusion. The Biocor stentless bioprosthesis has an excellent hemodynamic function and confers a good long-term outcome. This patient population could be regarded as ‘cured’ from valve disease since the observed survival did not differ from the expected survival for an age- and gender-matched Swedish comparison population, a conclusion that is also supported by a constant relative survival after the first postoperative year. However, despite excellent long-term hemodynamics, patients with stentless bioprostheses need to be evaluated with echocardiography at regular intervals to discover the rare cases of progressive aortic regurgitation.  相似文献   

17.

Purpose

The collum femoris preserving (CFP) uncemented prosthesis has a bone-preserving, high subcapital neck resection and a short anatomical stem. The ideal arthroplasty option in the younger, active patient is a subject of some debate. We evaluated midterm outcomes of the CFP in this patient population.

Methods

A prospective, consecutive cohort of 75 CFP total hip replacement (THR) patients with a mean age of 52 years was followed for a mean of 9.3 years. Patients were assessed using the Harris Hip Score (HHS). Pain was assessed using a visual analogue scale (VAS) and activity levels using the University of California, Los Angeles (UCLA) score. Radiographs were evaluated for evidence of loosening. Survivorship was calculated with an endpoint of revision for aseptic loosening or radiographic evidence of loosening.

Results

Mean HHS improved from a mean of 50 pre-operatively to 91 (p < 0.001) postoperatively. Mean pain score was 1, mean patient satisfaction was 9 and mean UCLA score was 6. Two acetabular components were revised for aseptic loosening; no stem required revision. Radiographically, no cases had evidence of loosening. Survivorship was 96.8 % for the acetabular component and 100 % for the stem at ten years. Three patients died from unrelated causes, and five were lost to follow-up.

Conclusions

Bone-preserving hip replacement has increased in popularity as hip replacement in younger and more active individuals increases. The CFP prosthesis has excellent midterm clinical function and survival and provides high levels of satisfaction in young patients.  相似文献   

18.
This paper reports on 41 immature patients whose scoliosis was treated by fixation of ribs on the convexity. All had progressive scoliosis, the curve deteriorating at more than 10° p.a., or the rib-vertebra angle difference being greater than 20°. Of the 24 with infantile idiopathic scoliosis examined 5 years after operation, 10 maintained the improvement obtained at operation and in a further 19 the rate of deterioration had been slowed.

Factors leading to a favourable outcome included: 1) An initial rib-vertebra angle difference of less than 30°. 2) Success in achieving convex rib fusion. 3) The use of the operation in patients with infantile idiopathic scoliosis. There was a less favourable outcome in congenital and adolescent scoliosis. Spirometric volumes were diminished immediately after operation. Costodesis is therefore contraindi-cated in patients with precarious respiratory function.  相似文献   

19.
21 elbows in 18 patients with rheumatoid arthritis were treated with a Souter-Strathclyde total elbow prosthesis. 18 elbows were included in a radiostereometry (RSA) study. The aim of this clinical RSA study was to assess the three-dimensional micromotion pattern of the Souter-Strathclyde prosthesis, and thereby gain insight in the aseptic loosening process of this prosthesis. Implants were defined as at risk of aseptic loosening when the translation rate during the second postoperative year was more than 0.4 mm along one or more coordinate axes and/or the rate of rotation was more than 1° about one or more coordinate axes. Clinical examination revealed an increase in the range of motion and a marked reduction in pain. The RSA showed that 8 of 18 humeral components were at risk of aseptic loosening, although no signs of such loosening - defined as a complete radiolucent line of 2 mm or more - were found on the plain radiographs. In 7 humeral components, an anterior tilt about the transverse axis was seen that resulted in an anterior translation of the proximal tip and a posterior translation of the component's trochlea. Long-term studies of the Souter-Strathclyde prosthesis, have shown that this rotation is a specific pattern of failure in some implants. None of the ulnar components was at risk for aseptic loosening. Improvements in fixation of the Souter-Strathclyde total elbow arthroplasty should focus on the humeral component. At present, the lateral flange of the implant is enlarged to improve rotational stability about the transverse and longitudinal axes. The effect of this change in design on micromotion of the Souter-Strathclyde total elbow prosthesis will be studied in a randomized RSA study comparing the new design to the existing one.  相似文献   

20.
Objectives: The results of current surgical options for the treatment of permanent atrial fibrillation (AF) associated with mitral surgery are widely different, particularly in very enlarged left atria. The aim of this study was to assess the mid-term efficacy of cardiac autotransplantation for this goal, through a consistent reduction of left atrium volume and a complete isolation of the pulmonary veins. Methods: From April 2000 to September 2002, 30 patients (male/female 5/25) underwent cardiac autotransplantation for the treatment of mitral valve disease and concomitant permanent AF (>1 year). Surgical technique of bicaval heart transplantation was modified maintaining the connection of inferior vena cava in all but three cases. Twenty-eight patients had mitral valve replacement and two had mitral valve repair. Associated procedures were: aortic valve replacement (6 cases), tricuspid valve repair (2 cases), coronary re-vascularization (2 cases) and right atrium volume reduction (4 cases). Results: No hospital death occurred; 1 patient died 3 months post-operatively for pneumonia. At a mean follow-up of 21.1±7.7 months (range 6–35), 26 patients (89.7%) were in sinus rhythm and 3 (10.3%) in AF. Santa Cruz Score was 0 in 3 patients, 2 in 2 patients and 4 in the remaining 24 patients (82.7%). Mean left atrial diameter and volume decreased from 65.1±16.4 mm (range 50–130 mm) to 49.9±8.4 mm (range 37–78) (P<0.001) and from 118.3±68.4 ml (range 60–426) to 69.4±34.1 ml (range 31–226) (P=0.001), respectively, after the operation. Conclusions: Cardiac autotransplantation is a safe and effective option for the treatment of permanent AF in patients with mitral valve disease and severe dilation of left atrium.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号