共查询到20条相似文献,搜索用时 15 毫秒
1.
Fuglsang-Damgaard D Nielsen CH Mandrup E Fuursted K 《APMIS : acta pathologica, microbiologica, et immunologica Scandinavica》2011,119(10):681-688
Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS) is promising as an alternative to more costly and cumbersome methods for direct identifications in blood cultures. We wanted to evaluate a simplified pre-treatment method for using MALDI-TOF-MS directly on positive blood cultures using BacT/Alert blood culture system, and to test an algorithm combining the result of the initial microscopy with the result suggested by MALDI-TOF-MS. Using the recommended cut-off score of 1.7 the best results were obtained among Gram-negative rods with correct identifications in 91% of Enterobacteriaceae, 83% in aerobic/non-fermentative Gram-negative rods, whereas results were more modest among Gram-positive cocci with correct identifications in 52% of Staphylococci, 54% in Enterococci and only 20% in Streptococci. Combining the results of Gram stain with the top reports by MALDI-TOF-MS, increased the sensitivity from 91% to 93% in the score range from 1.5 to 1.7 and from 48% to 85% in the score range from 1.3 to 1.5. Thus, using this strategy and accepting a cut-off at 1.3 instead of the suggested 1.7, overall sensitivity could be increased from 88.1% to 96.3%. MALDI-TOF-MS is an efficient method for direct routine identification of bacterial isolates in blood culture, especially when combined with the result of the Gram stain. 相似文献
2.
Dridi B Raoult D Drancourt M 《APMIS : acta pathologica, microbiologica, et immunologica Scandinavica》2012,120(2):85-91
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) identification of Archaea has been limited to some environmental extremophiles belonging to distant taxa. We developed a specific protocol for MALDI-TOF-MS identification of Archaea and applied it to seven environmental human-associated Methanobrevibacter smithii, Methanobrevibacter oralis, Methanosphaera stadtmanae, and the recently described Methanomassiliicoccus luminyensi Archaea. After mechanical lyse, we observed a unique protein profile for each organisms comprising 7-24 peaks ranging from 3,015 to 10,632 Da with a high quality score of 7.38 ± 1.26. Profiles were reproducible over successive experiments performed at 1, 2, and 3-week growth durations and unambiguously distinguished the Archaea from all of the 3,995 bacterial spectra in the Brüker database. After the incorporation of the determined profiles into a local database, archaeal isolates were blindly identified within 10 min with an identification score of 1.9-2.3. The MALDI-TOF-MS-based clustering of these archaeal organisms was consistent with their 16S rDNA sequence-based phylogeny. These data prove that MALDI-TOF-MS profiling could be used as a first-line technique for the identification of human Archaea. In complement to previous reports for animal cells, Bacteria and giant viruses, MALDI-TOF-MS therefore appears as a universal method for the identification of living unicellular and multicellular organisms. 相似文献
3.
D. Martiny F. Debaugnies D. Gateff M. Gérard M. Aoun C. Martin D. Konopnicki A. Loizidou A. Georgala M. Hainaut M. Chantrenne A. Dediste O. Vandenberg S. Van Praet 《Clinical microbiology and infection》2013,19(12):E568-E581
For septic patients, delaying the initiation of antimicrobial therapy or choosing an inappropriate antibiotic can considerably worsen their prognosis. This study evaluated the impact of rapid microbial identification (RMI) from positive blood cultures on the management of patients with suspected sepsis. During a 6-month period, RMI by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) was performed for all new episodes of bacteraemia. For each patient, the infectious disease specialist was contacted and questioned about his therapeutic decisions made based on the Gram staining and the RMI. This information was collected to evaluate the number of RMIs that led to a therapeutic change or to a modification of the patient's general management (e.g. fast removal of infected catheters). During the study period, 277 new episodes of bacteraemia were recorded. In 71.12% of the cases, MALDI-TOF MS resulted in a successful RMI (197/277). For adult and paediatric patients, 13.38% (21/157) and 2.50% (1/40) of the RMIs, respectively, resulted in modification of the treatment regimen, according to the survey. In many other cases, the MALDI-TOF MS was a helpful tool for infectious disease specialists because it confirmed suspected cases of contamination, especially in the paediatric population (15/40 RMIs, 37.50%), or suggested complementary diagnostic testing. This study emphasizes the benefits of RMI from positive blood cultures. Although the use of this technique represents an extra cost for the laboratory, RMI using MALDI-TOF MS has been implemented in our daily practice. 相似文献
4.
《Clinical microbiology and infection》2014,20(10):1001-1006
Rapid identification of the causative microorganism is important for appropriate antimicrobial therapy of bloodstream infections. Bacteria from positive blood culture (BC) bottles are not readily available for identification by matrix-assisted laser desorption ionization—time of flight mass spectrometry (MALDI-TOF MS). Lysis and centrifugation procedures suggested for direct MALDI-TOF MS from positive BCs without previous culture are associated with additional hands-on processing time and costs. Here, we describe an alternative approach applying MALDI-TOF MS from bacterial cultures incubated very briefly on solid medium. After plating of positive BC broth on Columbia blood agar (n = 165), MALDI-TOF MS was performed after 1.5, 2, 3, 4, 5, 6, 7, 8, 12 and (for control) 24 h of incubation until reliable identification to the species level was achieved (score ≥2.0). Mean incubation time needed to achieve species-level identification was 5.9 and 2.0 h for Gram-positive aerobic cocci (GPC, n = 86) and Gram-negative aerobic rods (GNR, n = 42), respectively. Short agar cultures with incubation times ≤2, ≤4, ≤6, ≤8 and ≤12 h yielded species identification in 1.2%, 18.6%, 64.0%, 96.5%, 98.8% of GPC, and in 76.2%, 95.2%, 97.6%, 97.6%, 97.6% of GNR, respectively. Control species identification at 24 h was achieved in 100% of GPC and 97.6% of GNR. Ethanol/formic acid protein extraction performed for an additional 34 GPC isolates cultivated from positive BCs showed further reduction in time to species identification (3.1 h). MALDI-TOF MS using biomass subsequent to very short-term incubation on solid medium allows very early and reliable bacterial identification from positive BCs without additional time and cost expenditure. 相似文献
5.
《Clinical microbiology and infection》2014,20(11):1146-1157
Bacteria that produce extended-spectrum β-lactamases (ESBLs) are an increasing healthcare problem and their rapid detection is a challenge that must be overcome in order to optimize antimicrobial treatment and patient care. Matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry (MS) has been used to determine resistance to β-lactams, including carbapenems in Enterobacteriaceae, but the methodology has not been fully validated as it remains time-consuming. We aimed to assess whether MALDI-TOF can be used to detect ESBL-producing Enterobacteriaceae from positive blood culture bottles in clinical practice. In the assay, 141 blood cultures were tested, 13 of them were real bacteraemias and 128 corresponded to blood culture bottles seeded with bacterial clinical isolates. Bacteraemias were analysed by MALDI-TOF after a positive growth result and the 128 remaining blood cultures 24 h after the bacterial seeding. β-lactamase activity was determined through the profile of peaks associated with the antibiotics cefotaxime and ceftazidime and its hydrolyzed forms. Clavulanic acid was added to rule out the presence of non-ESBL mechanisms. Overall data show a 99% (103 out of 104) sensitivity in detecting ESBL in positive blood cultures. Data were obtained in 90 min (maximum 150 min). The proposed methodology has a great impact on the early detection of ESBL-producing Enterobacteriaceae from positive blood cultures, being a rapid and efficient method and allowing early administration of an appropriate antibiotic therapy. 相似文献
6.
《Indian journal of medical microbiology》2013,31(2):117-122
Purpose: The purpose of this study was to evaluate the identification of Mycobacterium tuberculosis which is often plagued with ambiguity. It is a time consuming process requiring 4-8 weeks after culture positivity, thereby delaying therapeutic intervention. For a successful treatment and disease management, timely diagnosis is imperative. We evaluated a rapid, proteomic based technique for identification of clinical mycobacterial isolates by protein profiling using matrix assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS). Materials and Methods: Freshly grown mycobacterial isolates were used. Acetonitrile/trifluoroacetic acid extraction procedure was carried out, following which cinnamic acid charged plates were subjected to identification by MALDI-TOF MS. Results: A comparative analysis of 42 clinical mycobacterial isolates using the MALDI-TOF MS and conventional techniques was carried out. Among these, 97.61% were found to corroborate with the standard methods at genus level and 85.36% were accurate till the species level. One out of 42 was not in accord with the conventional assays because MALDI-TOF MS established it as Mycobacterium tuberculosis (log (score)>2.0) and conventional methods established it to be non-tuberculous Mycobacterium. Conclusions: MALDI-TOF MS was found to be an accurate, rapid, cost effective and robust system for identification of mycobacterial species. This innovative approach holds promise for early therapeutic intervention leading to better patient care. 相似文献
7.
W. Moussaoui B. Jaulhac A.-M. Hoffmann B. Ludes M. Kostrzewa P. Riegel G. Prévost 《Clinical microbiology and infection》2010,16(11):1631-1638
Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) is now widely used for marker/multibiomarker detection in medical diagnosis. We tested a new protocol for bacterial identification from blood culture broths in hospital routine by using collection tubes with separator gels on 503 included samples examined over 3 months, where 1.5 mL was injected by a syringe into BD Vacutainer tubes from BACTEC-positive bottles, before processing for bacterial protein extraction. Samples were loaded in duplicate onto the MALDI MS target, allowing a series of 12 samples to be processed in duplicate within 80 min by using Biflex III and BioTyper 2.0 software (Bruker). Including polymicrobial samples, 193 of 213 of Gram-negative bacteria (91.08%) and 284 of 319 of Gram-positive bacteria (89.02%) were correctly identified at the species level. Enterobacteriaceae constituted 35.15% of all species found, Staphylococaceae 37.96%, Streptococaceae and Enterococaceae 20.85%, Pseudomonadaceae 1.69%, and anaerobes 2.44%. In most of the polymicrobial samples, one of the species present was identified (80.9%). Seven isolates remained misidentified as Streptococcus pneumoniae, all belonging to Streptococcus mitis. Staphylococcus aureus was identified better when grown on anaero-aerobic medium, and MALDI BioTyper identification scores as low as 1.4 were pertinent, provided that four successive proposals of the same species were given. This new protocol correlates with conventional microbiology procedures by up to 90%, and by >95% for only monomicrobial samples, and provides a decreased turn-around time for identification of bacteria isolated from blood cultures, making this technology suitable also for blood cultures, with less delay and cost decreases in bacterial diagnostics, and favouring better care of patients. 相似文献
8.
随着人类基因组测序工作的完成,多态性遗传标记及其检测手段日益受到重视。基质辅助激光解吸/离子化飞行时间质谱作为一种高通量的单核苷酸多态性分型技术受到关注,它不仅可以分析单核苷酸多态性,还可以进行微测序、分析短串联重复序列。目前的分析方法有:引物延伸法、连接酶反应法、肽核酸法、侵入法等。 相似文献
9.
L. Ferreira F. Sánchez-Juanes I. Porras-Guerra M.I. García-García J.E. García-Sánchez J.M. González-Buitrago J.L. Muñoz-Bellido 《Clinical microbiology and infection》2011,17(4):546-551
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) allows a fast and reliable bacterial identification from culture plates. Direct analysis of clinical samples may increase its usefulness in samples in which a fast identification of microorganisms can guide empirical treatment, such as blood cultures (BC). Three hundred and thirty BC, reported as positive by the automated BC incubation device, were processed by conventional methods for BC processing, and by a fast method based on direct MALDI-TOF MS. Three hundred and eighteen of them yield growth on culture plates, and 12 were false positive. The MALDI-TOF MS-based method reported that no peaks were found, or the absence of a reliable identification profile, in all these false positive BC. No mixed cultures were found. Among these 318 BC, we isolated 61 Gram-negatives (GN), 239 Gram-positives (GP) and 18 fungi. Microorganism identifications in GN were coincident with conventional identification, at the species level, in 83.3% of BC and, at the genus level, in 96.6%. In GP, identifications were coincident with conventional identification in 31.8% of BC at the species level, and in 64.8% at the genus level. Fungaemia was not reliably detected by MALDI-TOF. In 18 BC positive for Candida species (eight C. albicans, nine C. parapsilosis and one C. tropicalis), no microorganisms were identified at the species level, and only one (5.6%) was detected at the genus level. The results of the present study show that this fast, MALDI-TOF MS-based method allows bacterial identification directly from presumptively positive BC in a short time (<30 min), with a high accuracy, especially when GN bacteria are involved. 相似文献
10.
目的建立基质辅助的激光解吸附离子化-飞行时间质谱法(MALDI-TOF—MS)测定血清脑硫苷脂的方法,并探讨人血清参考范围。方法经去蛋白、各种条件的高温皂化、萃取、干燥后的血清,用不同浓度的过滤溶剂在MonoTip C18洗脱管中过滤杂质.以桂皮酸为基质,在飞行质谱仪上点样测定。在优化后的条件下测定方法的线性范围、回收率与人血清参考范围。结果用90%甲醇配制的浓度0.1mol/LNaOH在150℃皂化25min、用体积比6:4的蒸馏水与甲醇在MonoTip C18管过滤杂质效果最好。方法线性范围为浓度0—20nmol/ml,回收率为73.7%-75.5%,40例健康人血清参考范围:浓度(8.2±1.5)nmol/ml,男女间差异无统计学意义(P〉0.05)。结论通过飞行质谱仪测定血清脑硫苷脂的含量,具有较高的准确性和线性范围。 相似文献
11.
12.
Oh HB Kim SO Cha CH Hong SP Folk WR Kim KM Suh DJ 《Journal of medical virology》2008,80(10):1712-1719
Previous surveys of the prevalence of hepatitis C virus (HCV) in Korea have identified types 1 and 2, but little has been said of other genotypes and viral subtypes. In this study, HCV genotypes in Korea were investigated using Restriction Fragment Mass Polymorphism (RFMP) assay, a sensitive and specific method for genotyping based on MALDI-TOF mass spectrometry. A total of 1,043 independent serum samples from HCV-infected patients were analyzed. Of interest, 15 subjects (1.4%) were determined to contain HCV genotype 6 and 46 subjects (4.4%) contained mixed genotypes with the most prevalent genotypes being HCV 1b and 2a/c (45.0% and 35.4%, respectively). The 15 subjects with HCV genotype 6 comprised eight cases of subtype 6c, including one case of mixed infection with 1b, three cases of HCV 6a, and six cases of unassigned subtypes. Sequencing corroborated the identity of genotype 6 from 13 subjects, while the line probe assay (LiPA) mis-identified them as genotype 1b. The majority (7/9) of the genotype 6 patients enrolled for interferon/ribavirin therapy, achieved a sustained virologic response. The ability of the RFMP assay to differentiate various HCV genotypes should enable better analysis of the relationship between HCV genotype and disease prognosis. 相似文献
13.
《Clinical microbiology and infection》2014,20(8):O468-O475
Peptide nucleic acid fluorescence in situ hybridization (PNA FISH) is a molecular diagnostic tool for the rapid detection of pathogens directly from liquid media. The aim of this study was to prospectively evaluate PNA FISH assays in comparison with culture-based matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) identification, as a reference method, for both blood and cerebrospinal fluid (CSF) cultures, during a 1-year investigation. On the basis of the Gram stain microscopy results, four different PNA FISH commercially available assays were used (‘Staphylococcus aureus/CNS’, ‘Enterococcus faecalis/OE’, ‘GNR Traffic Light’ and ‘Yeasts Traffic Light’ PNA FISH assays, AdvanDx). The four PNA FISH assays were applied to 956 positive blood cultures (921 for bacteria and 35 for yeasts) and 11 CSF cultures. Among the 921 blood samples positive for bacteria, PNA FISH gave concordant results with MALDI-TOF MS in 908/921 (98.64%) samples, showing an agreement of 99.4% in the case of monomicrobial infections. As regards yeasts, the PNA FISH assay showed a 100% agreement with the result obtained by MALDI-TOF MS. When PNA FISH assays were tested on the 11 CSF cultures, the results agreed with the reference method in all cases (100%). PNA FISH assays provided species identification at least one work-day before the MALDI-TOF MS culture-based identification. PNA FISH assays showed an excellent efficacy in the prompt identification of main pathogens, yielding a significant reduction in reporting time and leading to more appropriate patient management and therapy in cases of sepsis and severe infections. 相似文献
14.
《Clinical microbiology and infection》2014,20(12):1366-1371
The clinical diagnosis of mould infections currently involves complex species identification based on morphological criteria, which is often prone to error. Employing an extensive mould species reference spectral library (up to 2832 reference spectra, corresponding to 708 strains from 347 species), we assessed the extent to which matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) enhanced the accuracy of species identification. MALDI-TOF MS data were validated against morphology-based and DNA sequence-based results with 262 clinical isolates collected over a 4-month period in 2013. The implementation of MALDI-TOF MS resulted in a dramatic improvement in mould identification at the species level (from 78.2% to 98.1%) and a marked reduction in the misidentification rate (from 9.8% to 1.2%). We then compared the mould identification results obtained before (i.e. 2011) and after (i.e. 2013) the implementation of MALDI-TOF MS in routine identification procedures, which showed an improvement from 64.57% to 100%. Reassessment of a set of isolates from 2011 with this procedure, including MALDI-TOF MS, yielded an increase in species diversity from 16 to 42 species. Finally, application of this procedure during a 16-month period (2012–2013) enabled the identification of 1094 of 1107 (98.8%) clinical mould isolates corresponding to 107 distinct species. MALDI-TOF MS-based mould species identification may soon challenge traditional techniques in the clinical laboratory, as patient prognosis is largely contingent on rapid and accurate diagnosis. 相似文献
15.
Until recently, matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) techniques for the identification of microorganisms remained confined to research laboratories. In the last 2 years, the availability of relatively simple to use MALDI-TOF MS devices, which can be utilized in clinical microbiology laboratories, has changed the laboratory workflows for the identification of pathogens. Recently, the first prospective studies regarding the performance in routine bacterial identification showed that MALDI-TOF MS is a fast, reliable and cost-effective technique that has the potential to replace and/or complement conventional phenotypic identification for most bacterial strains isolated in clinical microbiology laboratories. For routine bacterial isolates, correct identification by MALDI-TOF MS at the species level was obtained in 84.1–93.6% of instances. In one of these studies, a protein extraction step clearly improved the overall valid identification yield, from 70.3% to 93.2%. This review focuses on the current state of use of MALDI-TOF MS for the identification of routine bacterial isolates and on the main difficulties that may lead to erroneous or doubtful identifications. 相似文献
16.
SELDI-TOF-MS技术筛选NSCLC血清肿瘤标志物 总被引:3,自引:0,他引:3
目的 分析非小细胞肺癌(NSCLC)血清蛋白表达谱的改变,筛选并建立NSCLC血清蛋白的差异表达谱。方法 应用表面增强激光解析电离化飞行时间质谱(SELDI-TOF-MS,简称SELDI-TOF或SELDI)技术,分析100例NSCLC患者和100例正常对照血清,获得蛋白表达图谱。用Biomarker Pattern(BPS)软件分析NSCLC差异蛋白并初步建立诊断模型。通过盲筛进一步验证诊断模型。结 果 发现NSCLC患者血清与正常人有16个显著差异的蛋白波峰,显著高表达8个(P<0.001)。显著低表达8个(P<0.001)。经BPS软件分析,建立分类树模型,其诊断的灵敏度为100%,特异度为100%。100例样本盲筛验证结果显示,其灵敏度为96.15%,特异度为95.83%。无吸烟史患者较有吸烟史患者血清中显著高表达蛋白质波峰有3个(P<0.05)。鳞癌患者较腺癌患者血清中显著高表达蛋白质波峰有2个(P<0.01)。不同病理分期患者之间未发现差异蛋白峰。结 论 SELDI-TOF-MS 技术可筛选出NSCLC差异性蛋白并建立NSCLC诊断的分类树模型,有望成为NSCLC早期诊断的辅助指标。 相似文献
17.
Sabrina Carroccio Paola Rizzarelli Daniela Zampino 《Macromolecular chemistry and physics.》2011,212(24):2648-2666
The products derived from thermo‐oxidation of poly(bisphenol A carbonate) (PC) and their related degradation pathways are investigated. PC degradation is carried out at 300 °C in air. The oxidized products are analyzed for the first time by using direct electrospray mass spectrometry (MS) and matrix‐assisted laser desorption ionization time of flight MS. Together with the formation of bisphenol A oligomers, several new structures containing biphenyl units, phenols, acetophenones, alcohols, acids, and xanthones molecules are detected. The use of thin films, instead of PC bulk, allows one to obtain precise information about mechanisms involved during thermo‐oxidative processes and to establish a new order of priorities among the renowned degradative reactions. 相似文献
18.
《Clinical microbiology and infection》2018,24(12):1342.e5-1342.e8
The identification of Nocardia isolates still represents a challenge for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) despite its acceptance for most bacterial and fungal isolates. In this study we evaluate the identification of Nocardia isolates using direct spotting and an updated database.Overall, 82 Nocardia isolates belonging to 13 species were identified by DNA sequence analysis of the 16S rRNA and secA1 genes. Nine of these well-characterized isolates from 6 Nocardia species were used to create an in-house library. The remaining 73 isolates were directly spotted on the target plate and on-plate protein extraction was performed. The protein spectra obtained were analyzed by MALDI-TOF MS using the BDAL database (Bruker Daltonics) updated with 6,903 MSPs or the combination of this commercial database and our in-house library.As a result, the use of the commercial database alone and in combination with the in-house library yielded 94.5% and 95.9% of correct species-level identifications, respectively, No isolate was misidentified at the genus level with either database. Besides, the use of the in-house library allowed the species-level identification of a N. otitidiscaviarum isolate that could only be identified at the genus-level with a score value <1.6 using the commercial database.In conclusion, the implementation of the direct spotting method and the in-house database provided a high rate of correct species assignment of Nocardia isolates despite the low number of isolates added. Further addition of well-characterized Nocardia isolates may ensure the rapid, accurate and inexpensive identification of most isolates encountered in the routine of the microbiology laboratory. 相似文献
19.
Helen Chirowodza Patrice C. Hartmann Harald Pasch 《Macromolecular chemistry and physics.》2014,215(8):791-801
Reversible addition‐fragmentation chain transfer (RAFT)‐mediated grafting of polystyrene from clay is investigated using advanced analytical methods to elucidate the polymerization mechanism occurring at the clay surface and in solution. The chain‐end structures of the grafted polymer grown from a surface‐attached cationic functionalized RAFT agent, and the free polymer chains generated from a non‐functionalized RAFT agent are investigated using size exclusion chromatography, matrix‐assisted laser desorption/ionization time‐of‐flight (MALDI‐TOF) mass spectrometry, MALDI‐TOF–collision‐induced dissociation mass spectrometry, and 1H NMR spectroscopy. The results obtained show that free and surface‐confined polymer chains undergo significant conventional chain‐transfer reactions in addition to reversible addition–fragmentation chain transfer. This information provides additional new insight into the polymerization mechanism.
20.
《Advances in medical sciences》2021,66(2):326-335
PurposeRenal cell carcinoma (RCC) is a very aggressive and often fatal heterogeneous disease that is usually asymptomatic until late in the disease. There is an urgent need for RCC specific biomarkers that may be exploited clinically for diagnostic and prognostic purposes.Materials/methodsSerum and urine samples were collected from patients with diagnosed kidney cancer and assessed with gold nanoparticle enhanced target (AuNPET) surface assisted-laser desorption/ionization mass spectrometry (SALDI MS) based metabolomics and statistical analysis.ResultsA database search allowed providing assignment of signals for the most promising features with a satisfactory value of the area under the curve and accuracy. Four potential biomarkers were found in urine and serum samples to distinguish clear cell renal cell carcinoma (ccRCC) from controls, 4 for the ccRCC with and without metastases, and 6 metabolites to distinguish low and high stages or grades.ConclusionsThis pilot study suggests that serum and urine metabolomics based on AuNPET-LDI MS may be useful in distinguishing types, grades and stages of human RCC. 相似文献