首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
目的探讨GE1.5TEXCITE ⅢHD磁共振成像仪对肝脏DWI成像的可重复性。方法采用GE1.5TEXCITEⅢ超导型磁共振成像仪、八通道体线圈,对3O例健康志愿者在不同时间(24H-14D内)行两次DWI成像扫描。扫描完成后将图像传入adw4.2工作站,利用functool2软件得到两次扫描的ADC图并计算出ADC值、eADC值,然后进行统计学分析。结果两次不同时间行肝脏弥散加权成像所得到的ADC和eADC值无统计学差异(P〉0.05)。结论GE1.5TEXCITEⅢHD磁共振对肝脏DWI成像具有较好的可重复性,可进一步用于肝脏良恶性病变的研究。  相似文献   

2.
目的 探讨磁共振22b值(0~ 5000 s/mm2)非高斯弥散加权成像在健康成人脑白质和胶质瘤应用的可重复性.方法 12名健康志愿者和65名胶质瘤患者进行22 b值eDWI(enhanced diffusion weighted imaging)磁共振扫描.前者进行连续2次eDWI扫描,选取基底节层面和半卵圆中心层面深部白质为感兴趣区;后者进行单次eDWI扫描,由2名神经放射医师分别在肿瘤最大层面的肿瘤实质区放置感兴趣区,工作站进行双指数和拉伸指数模型后处理;前者对2次扫描双指数模型拟合的慢弥散系数Dslow(slow diffusion coefficient)、快弥散系数Dfast(fast diffusion coefficient)和快弥散容积分数PF(perfusion fraction of Dfast)以及拉伸指数模型拟合的分布弥散系数DDC(distributed diffusion coefficient)和不均质指数α进行配对t检验、计算变异系数(coefficient of variability,CV)和绘制Bland-Altman(B-A)散点图;后者对2次测量的Dslow、Dfast、PF、DDC和α进行观察者间一致性检验,并计算CV.结果 健康志愿者各参数2次测量配对比较差异均无统计学意义(P>0.05),CV值均小于5%,B-A散点图绝大多数(≥11/12)测值均位于95%一致性范围内;胶质瘤各参数2次测量一致性系数均大于0.75(P<0.001),Dfast和PF的CV值最大,范围在5.0%~11.5%之间,其次是DDC和Dslow,α最小,CV值小于2%,除α外,其余参数CV值均随胶质瘤级别增高而增大.结论 健康脑白质评价中非高斯弥散加权成像各参数均具有较好的可重复性;胶质瘤评价中拉伸指数模型α具有最好的可重复性.  相似文献   

3.
磁共振弥散加权成像在临床中的应用   总被引:6,自引:0,他引:6  
目的:探讨磁共振弥散加权成像在临床中的应用。方法:阅读有关磁共振弥散加权成像的文献资料。结果:磁共振弥散加权成像在急性脑缺血性疾病、脑肿瘤、脑脓肿的分期[2]、肝脏肿瘤、鉴别乳腺肿瘤的良恶程度以及椎体病变的诊断上发挥了重要作用,但在应用中仍有一定局限性。结论:磁共振弥散加权成像将在临床疾病的诊断、鉴别诊断中发挥越来越大的作用。  相似文献   

4.
磁共振弥散加权成像诊断急性脑梗死的价值   总被引:7,自引:0,他引:7  
目的:评价弥散加权成像(DWI)在急性脑梗死诊断中的应用价值。方法:22例脑梗死患者(超急性2例,急性期12例,亚急性期8例)经DWI成像、T1WI、T2WI及FLAIR检查,比较不同序列间病灶的信号强度表现及病灶数目。结果:单纯脑梗死DWI均表现为高信号,伴有出血时表现为混杂信号;而T2WI/FLAIR检查中2例超急性患者未显著责任病灶,急性期内仅2例表现为高信号,其余表现为略高信号或等信号。综合比较三种检查中病灶与对侧相应部位信号强度,DWI组与FLAIR组及T2WI组间差别均有显著意义(方差分析PFLAR=0.001,PT2WI=0.038),DWI优于FLAIR及T2WI。本组共有9例于T2WI显示为多处病灶,而DWI均为单发病灶,且单发病灶部位与患者的症状及体征相符。结论:DWI对于急性脑梗死比T2WI及FLAIR具有更高的敏感性;有助于多次梗死患者急性责任病灶的检出;有助于诊断出血性脑梗死。  相似文献   

5.
目的观察磁共振弥散加权成像(DWI)诊断胎盘植入的价值。方法选择2014年6月至2016年6月于柳州市妇幼保健院临床产检或超声拟诊胎盘植入的妊娠晚期妇女50例为研究对象,患者均接受腹盆腔磁共振成像(MRI)检查。观察胎盘植入的MRI表现,以病理结果为准,探讨其诊断效力,并观察胎盘植入表观扩散系数(ADC)值变化及不同类型胎盘植入ADC值的差异。结果 MRI共诊断胎盘植入患者25例,包括粘连型11例、植入型9例、穿透型5例,诊断灵敏度为84.6%、特异度为87.5%、诊断符合率为86.0%。DWI图像中,胎盘植入表现为信号不均18例,胎盘局部向肌层突出7例,宫颈肿胀8例,子宫肌层低信号显示不清或中断10例。植入性胎盘植入部分的ADC值为(1.983±0.415)mm~2/s,显著高于非植入性胎盘的(1.765±0.365)mm~2/s及植入性胎盘的非植入部分的(1.786±0.354)mm~2/s(P<0.05)。粘连型胎盘ADC值为(1.896±0.398)mm~2/s,植入型胎盘ADC值为(1.975±0.401)mm~2/s,穿透型胎盘ADC值为(1.997±0.359)mm~2/s,三者差异无统计学意义(F=0.146,P>0.05)。结论 MRI可以清晰地显示胎盘植入特征,诊断准确率高,DWI可以对其进行形态学和量化评估。  相似文献   

6.
目的:探讨磁共振弥散加权成像及ADC值在鼻咽癌颅底放射治疗疗效评价中的应用价值。方法:对42例颅底侵犯的鼻咽癌患者,在治疗前和治疗结束时行常规磁共振和弥散加权成像检查,并分别测量颅底部位的ADC值。随访12个月以上分为复发组6例和对照组36例,采用SPSS13.0统计软件对其治疗前后所测ADC值数据进行统计分析。结果:两组间的ADC值相比,复发组的ADC值明显降低;复发组与对照组的颅底病灶治疗前ADC均值分别为(0.782±0.028)×10-3mm^2·s^-1及(0.821±0.029)×10-3mm^2·s^-1,两组间差异无统计学意义(P〉0.05);治疗后ADC均值分别为(1.034±0.084)×10^-3mm^2·s^-1及(1.506±0.110)×10-3mm^2·s^-1,两组间差异有统计学意义(P〈0.05)。结论:鼻咽癌颅底侵犯的患者,在经过放疗后病灶会明显缩小或消退,对应部位的ADC值也会有所不同;治疗后颅底部位的ADC值可能成为一种新的评价鼻咽癌颅底放射治疗疗效的指标,且对于鼻咽癌颅底复发有早期发现、早期诊断的作用。  相似文献   

7.
短暂性脑缺血发作(Transient ischemic attack,TIA)传统上是指历时短暂并经常反复发作的局限性供血障碍导致的供血区局限性神经功能缺失症状,24 h内症状完全消失,不遗留任何神经功能缺损,近年来随着影像学技术的发展使我们对TIA有了新的认识,本文拟对磁共振成像在TIA诊断方面的进展做一综述。  相似文献   

8.
影响磁共振弥散加权成像信号的因素   总被引:9,自引:0,他引:9  
磁共振弥散加权成像 (DWI)反映了水分子的微观弥散运动 ,是从细胞及分子水平来进行疾病研究的新技术 ;其成像原理及影响因素较复杂。对b值 (即弥散敏感因子 )、表观弥散系数 (ADC)、各向异性、T2 穿透效应及伪影等影响因素分别加以阐述 ,有助于对弥散成像信号的理解  相似文献   

9.
姜黄维  钱琦金  平林敏 《浙江医学》2017,39(11):897-899
目的探讨磁共振弥散加权成像(DWI)对强直性脊柱炎(AS)的诊断价值。方法61例AS患者根据Bath强直性脊柱炎疾病活动指数(BASDAI)分为活动组37例、稳定组24例,利用DWI测定骶髂关节、L5椎体的表观弥散系数(ADC),并比较两组的差异。结果活动组ADC、rADC均低于稳定组,差异均有统计学意义(均P<0.05);两组间ADC0比较差异无统计学意义(P>0.05)。结论利用DWI测定的ADC值能定量评估AS的临床分期,并评价AS的疗效。  相似文献   

10.
磁共振弥散加权成像在骨肿瘤诊断中的应用   总被引:3,自引:0,他引:3  
磁共振弥散加权成像 (diffusion weightedimaging ,DWI)是一种在分子水平无创性检查组织结构及其功能的磁共振影像学方法 ,其在神经系统应用较多 ,主要是检查早期脑梗塞。近年逐渐被应用于骨肿瘤的诊断 ,主要用于鉴别脊柱的良性骨折和恶性骨折 ,判断肿瘤的坏死区 ,鉴别肿瘤术后软组织改变和复发等[1] 。1 基 本 原 理弥散 (diffusion)指分子的随机运动 ,即布朗运动。DWI显示的主要是细胞外水分子的弥散 ,另外还包括细胞内水分子的弥散、跨膜运动、微灌注等[1,2 ] 。以DWI常用的自旋回波序列…  相似文献   

11.
目的 研究磁共振弥散加权成像(DWI)技术在脑梗死诊断中的应用价值.方法 应用DWI和常规磁共振成像(MRI)平扫对46例脑梗死患者进行检查,对所得的结果进行总结分析.结果 超急性期13例病灶DWI全部显示为明显高信号,T2WI和T2Flair信号强度无明显异常改变;急性期22例脑梗死患者病灶DWI全部显示为高信号,T2WI和T2Flair上也均表现为高或稍高信号,检出率为100%;亚急性期7例DWI表现为稍高信号,较急性期信号下降,T2WI和T2Flair为高信号;慢性期4例DWI表现为等信号或低信号,T2WI上表现为明显高信号.结论 DWI对早期脑梗死的诊断准确率高,明显优于常规MRI.  相似文献   

12.
Objective To evaluate the value of whole-body diffusion weighted imaging (WB-DWI) on detection of malignant metastasis. Methods Forty-six patients with malignant tumors underwent WB-DWI examinations between April 2007 and August 2007 in our hospital. Before WB-DWI examination, the primary cancers of all the patients were confirmed by pathology, and the TNM-stage was assessed with conventional magnetic resonance imaging (MRI) or computed tomography (CT). WB-DWI was performed using short TI inversion recovery echo-planar imaging (STIR-EPI) sequence. Abnormal high signal intensities on WB-DWI were considered as metastases. The results of WB-DWI were compared with other imaging modalities. For the assessment of the diagnostic capability of WB-DWI, WB-DWI were compared with CT for demonstrating mediastinal lymph node metastases and lung metastases, and with conventional MRI for demonstrating metastases in other locations. Results WB-DWI demonstrated 143 focuses, 14 routine imaging. The number of bone metastases depicted of which were diagnosed to be benign lesions in on WB-DWI and routine imaging was 85 and 86; lymph node metastases was 17 and 18; liver metastases was 14 and 14; lung metastases was 4 and 8; and brain metastases was 6 and 8, respectively. WB-DWI failed to detect 12 metastatic lesions including 3 osteoplastic bone metastases, 4 lung metastases, 3 mediastinal lymph node metastases, and 2 brain metastases Four metastatic lesions including 2 deltopectoral lymph nodes and 2 rib metastases were detected with WB-DWI alone, all of which evolved greatly during clinical follow-up for more than 6 months. WB-DWI had higher detection rates for metastatic lesions in liver, bone, and lymph nodes than those in lung and brain ( X^2=30, P〈0.001). Conclusions WB-DWI could detect most of metastatic lesions that were diagnosed with conventional MRI and CT. The limitations of WB-DWI might be had high false-positive rate and low efficiency in detecting mecliastinal lymph node, brain, and lung metastases.  相似文献   

13.
目的 探讨分段读出长可变回波序列(Readout Segmentation of Long Variable Echo Trains,RESOLVE)在脑肿瘤高场强术中磁共振扩散加权成像(Diffusion-Weighted Imaging,DWI)中的应用价值.方法 采用双室移动磁体高场强磁共振成像系统,对21例胶质...  相似文献   

14.
目的:探讨核磁共振新技术全身弥散成像(WB-DWI)在临床诊断中的应用优势。方法:通过对核磁共振全身弥散成像技术原理的阐述,分析此项新的成像技术的优势。结果:核磁共振全身弥散成像技术有易行、便捷、高敏感、无辐射等优点,对于全身肿瘤筛查有很高的敏感性,检查费用相对较低。结论:磁共振全身弥散成像方法简单,对全身肿瘤的筛查具有较高的临床应用价值。  相似文献   

15.
目的 :运用磁共振弥散加权成像技术 (MRDWI)评估近似弥散系数 (ADC)在星形细胞瘤的细胞密度和病理分级中的作用。方法 :术前进行MRI和MRDWI检查且经手术病理证实的 3 4例星形细胞瘤患者 ,其中Ⅰ~Ⅱ级 (低级别 ) 2 6例 ,Ⅲ~Ⅳ级 (高级别 ) 8例。在MRI上计算瘤体的ADC值 ,运用AdobePhotoshop 7.0软件分析星形细胞瘤的细胞密度 ,用SPSS 10 .0软件对资料进行处理。结果 :高级别星形细胞瘤的ADC为 ( 7.3 4± 2 .95 )× 10 -4mm2 /s ,低级别星形细胞瘤的ADC ( 13 76± 3 3 1)× 10 -4mm2 /s ,两者之间差异有显著性 (t =4 913 ,P <0 .0 0 1) ;高级别星形细胞瘤的细胞密度为 ( 19 81± 9 73 ) % ,明显大于低级别星形细胞瘤的细胞密度( 4 74± 2 96) % (t =4 3 2 ,P <0 .0 0 3 ) ;星形细胞瘤的ADC值与细胞密度呈显著负相关 (r =-0 5 3 5 ,P =0 .0 0 1)。结论 :星形细胸瘤的细胞密度对磁共振弥散加权成像中的ADC值贡献很大 ;MRDWI对星形细胞瘤的细胞密度的预测和评价很有价值 ;MRDWI磁共振散加权成像具有对星形细胞瘤的良、恶性程度进行预测的潜能  相似文献   

16.
磁共振灌注加权成像是近年来随着磁共振快速成像序列的出现而发展起来的一项功能成像技术,能够直观的反映组织、器官的血流动力学和微循环灌注情况,是影像学从形态学到功能学发展的一种体现。胰腺癌是胰腺最常见的恶性肿瘤,其临床诊断及疗效评估主要依靠影像学检查方法。本文综述了MR灌注成像的原理、意义及其在胰腺癌的术前诊断、鉴别诊断及临床治疗中的应用现状。  相似文献   

17.
目的通过分析脑梗死患者磁共振(MRI)弥散加权成像(DWI)表观扩散系数(ADC)值的变化,探讨脑梗死不同时期脑水肿的变化规律及相应水肿期丁苯酞软胶囊疗效。方法选取2013年1月~2014年6月期间收治的脑梗死并行磁共振DWI检查的病例269例,采集脑梗死后超早期(≤6 h)、急性期(6~24 h)、坏死期(24~48 h)、软化期(48 h~3 W)ADC值变化,筛选出58例服用丁苯酞软胶囊患者,分为48 h组(30例)、48 h组(28例),进行NIHSS评分(National Institute of Health Stroke Scale)。结果急性脑梗死超早期、急性期、坏死期及软化期病灶侧ADC均值分别为0.524±0.080,0.401±0.081,0.369±0.084、0.524±0.100,坏死期与其它期比较,ADC值均明显下降(P0.001)。同时,48 h、48 h组患者,治疗后NIHSS评分〔4.97±2.414 vs.8.46±3.061〕较治疗前(10.50±3.684 vs.11.32±1.375〕明显降低(P0.001〕,治疗2周后48 h组NIHSS评分较48 h组明显改善(P0.001)。结论 ADC可反映脑梗死细胞毒性水肿向血管源性水肿的演变过程,丁苯酞软胶囊治疗脑梗死能改善神经功能缺损,48 h之内治疗效果优于48 h后。  相似文献   

18.
陈博 《医学研究杂志》2016,45(12):138-141
目的 探究磁共振扩散加权成像联合动态增强对乳腺病变的诊疗实效性。方法 选取2012年12月~2015年12月在笔者医院进行治疗的乳腺病变患者111例118个病灶,分别同时进行动态增强扫描(A组)和磁共振扩散加权成像检查(B组)及联合检测(C组),对其形态学、血流动力学等进行分析。结果 肿块性病变中,肿块边缘、毛刺征、ADC值中差异有统计学意义(P<0.05);边缘不光滑、有毛刺、内部增强不均匀、廓清型TIC曲线为有显著意义恶性征象;形状不规则、平台型曲线有恶性倾向但不显著。非肿块性病变中,良恶性病变中TIC差异有统计学意义(P<0.05);廓清型TIC曲线为恶性征象;平台型曲线有恶性倾向但差异无统计学意义(P>0.05)。C组ROC曲线下面积值均数>0.9,明显高于单纯方法的B、C组,故诊断效能最高,差异有统计学意义(P<0.05)。肿块性病变中,敏感度为80.3%(41/51),特异性为75.9%(22/29),准确性为78.8%(63/80);非肿块性病变中,敏感度为80.0%(20/25),特异性为76.9%(10/13),准确性为78.9%(30/38),差异无统计学意义(P>0.05)。结论 磁共振扩散加权成像联合动态增强对乳腺病变的诊疗特异性强敏感度高,应在临床推广使用。  相似文献   

19.
弥散加权磁共振成像在超急性脑梗死诊断中的应用价值   总被引:1,自引:0,他引:1  
张荣江 《医学综述》2007,13(18):1425-1427
急性脑血管意外(脑卒中)是常见多发病,起病急,进展快,预后差,占死因之首位。其中脑梗死占脑卒中的80%~85%,具有高发病率、高病死率、高致残率的特点,近10%的患者可于发病急性期内死亡,其早期诊断是及时有效治疗的关键。现就磁共振弥散加权成像(DWI)对超急性脑梗死早期诊断及其临床价值进行综述。  相似文献   

20.
朱明  王松 《医学综述》2007,13(24):2006-2008
功能磁共振成像已比较广泛地用于颅脑检查,尤以磁共振弥散加权像(DWI)和灌注加权像(PWI)应用较多。DWI对早期缺血改变非常敏感,DWI较常规T2加权图像能更早地发现脑缺血的改变。PWI能在超急性阶段提供非常有用的信息,在超早期脑缺血性卒中灌注图像改变要先于DWI图像改变。结合DWI和PWI技术可以帮助研究脑血流动力学与急性脑缺血发生发展之间的潜在规律,证实缺血半暗带、可逆与不可逆的组织,为溶栓治疗提供早期有效直观的影像学诊断依据。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号