首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到12条相似文献,搜索用时 15 毫秒
1.
2.
3.
BACKGROUND AND OBJECTIVE: Laser soldering of tissues is based on the application of a biological solder on the approximated edges of a cut. Our goal was to use laser soldering for sealing cuts in skin under temperature feedback control and compare the results with ones obtained using standard sutures. STUDY DESIGN/MATERIALS AND METHODS: Albumin solder was applied onto the approximated edges of cuts created in rat skin. A fiberoptic system was used to deliver the radiation of a CO(2) laser, to heat a spot near the cut edges, and to control the temperature. Laser soldering was carried out, spot by spot, where the temperature at each spot was kept at 65-70 degrees C for 10 sec. RESULTS: The tensile strength of laser-soldered cuts was measured after 3-28 days postoperatively and was found comparable to that of sutured cuts. Histopathological studies showed no thermal damage and less inflammatory reaction than that caused by standard sutures (P = 0.04). CONCLUSIONS: Temperature controlled laser soldering of cuts in rat skin gave strong bonding. The cosmetic and histological results were very good, in comparison to those of standard sutures.  相似文献   

4.
BACKGROUND AND OBJECTIVES: Current laser-assisted end-to-end anastomoses are performed by irradiating the vessel wall from outside after additional fixation with three to six sutures. These sutures are needed to provide adequate approximation of the vessel stumps. We present a new laser soldering technique that is based on an intraluminal laser light source centered in a balloon catheter, and external application of a solder. This technique was applied in vivo in order to test its feasibility under clinical conditions. STUDY DESIGN/MATERIALS AND METHODS: Seven white pigs were treated with a total of fourteen end-to-end laser-anastomoses of their saphenous arteries having outer diameters of 2 mm. The vessels were stented over an intraluminal balloon catheter, which was maximally dilated and which allowed for a precise approximation of the vascular stumps. An 808 nm diode laser was coupled into a specially designed optical fiber producing a 360 degrees radiation ring inside the balloon catheter. An indocyanine green (ICG) doped liquid albumin solder was applied on the external surface of the vascular stumps. Laser soldering was achieved by irradiating with a 808 nm laser diode for 75 seconds. Tightness of the anastomoses was evaluated by clamping the artery distal to the anastomosis for 1 hour, and patency was tested over an observation period of 3 hours, during which the animals were heparinized. Thereafter, the anastomoses were harvested for histomorphological examination. RESULTS: All anastomoses remained patent over the entire observation period. Some leakage was observed in three anastomoses, which was explained by a deviation of the illumination fiber from the center of the balloon leading to an inhomogeneous irradiation of the vessel wall. Histology revealed perfect adaptation of the vascular stumps. A segment of denaturated vascular collagen was observed, that corresponded to the irradiated, solder-covered zone. CONCLUSION: Patent, maximally dilated and well adapted microvascular anastomoses could be obtained without the need of stay sutures. A well centered laser light source is indispensable for avoiding inhomogenous welding, thus causing leakage.  相似文献   

5.
6.
7.
8.
9.
10.
11.
12.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号