首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
PURPOSE: To report our experience of endovascular stent-graft placement in patients with descending thoracic aortic dissections and aneurysms and to evaluate the feasibility, safety, and clinical outcomes of the treatment. MATERIALS AND METHODS: Stent-grafts were placed in the descending thoracic aortas of 23 patients with saccular aneurysms (n = 11) and Stanford type B chronic aortic dissections of the descending thoracic and abdominal aorta (n = 12). All stent-grafts were individually constructed of self-expandable stainless steel stents covered with polytetrafluoroethylene. Vascular access was achieved through the femoral artery in all patients. Clinical status of each patient was monitored and postoperative CT was performed within 1 month of the procedure and at 3-12-month intervals after the procedures. RESULTS: Successful exclusion of the primary entry tears of dissections and the inlets of saccular aneurysms was achieved in all but two patients with aortic dissection. The overall technical success rate was 91.3% (dissection: 10 of 12 = 83%; aneurysm: 11 of 11 = 100%). All patients in whom technical success was achieved showed complete thrombosis and significant decrease in diameter of the thoracic false lumen (preoperative: 5.3 cm +/- 0.9; postoperative: 4.3 cm +/- 0.9; P = .004) or aneurysm sac (preoperative: 5.3 cm +/- 1.7; postoperative: 2.8 cm +/- 2.5; P = .001). In addition, five patients demonstrated complete resolution of the dissected thoracic false lumen (n = 2) and aneurysm sac (n = 3). However, in all patients with aortic dissection, the abdominal aorta was not significantly changed in size (P = .302) and shape and their false lumen flows remained persistent. Immediate postoperative complications were detected in 12 patients (52%); 10 had fever, leukocytosis, and elevation of C-reactive protein, another had wound infection, and another had transient abdominal pain. Three patients died 2, 3, and 12 months after the procedure: one from septic shock, another from underlying mediastinitis, and the other from an unexplained cause. The remaining 20 patients were well after the procedure (1-9 days; mean, 3 days), without any stent-graft-related complications or discomfort (follow up period: 10-65 mo; mean: 25.1 mo +/- 15.6). The cumulative survival rate after the stent graft was 100% at 30 days and 91% at 12 months. CONCLUSIONS: For treatment of aortic dissection and saccular aneurysm of the descending thoracic aorta, endovascular stent-graft repair may be a technically feasible and effective treatment modality.  相似文献   

2.
OBJECTIVE: The purpose of our study was to investigate the clinical experience and efficiency of translumenl endovascular stent-graft insertion using commercially available vascular endoprotheses. We studied seven patients with descending aortic dissection (type B) and four patients with penetrating aortic ulcer over a median follow-up period of 254 days during the years 1997-2000, using cross-sectional CT to evaluate the extent of the dissection, the distance between the entry tear and the left subclavian artery, and the diameter of the true lumen and the false lumen. CONCLUSION: Endovascular treatment of acute and chronic aortic type B dissections and penetrating ulcer is a minimally invasive method with a low complication rate that could be considered a feasible alternative to surgical repair. Depending on the length of the dissection, we recommend the placement of two overlapping stent-grafts in the thoracic aorta to stabilize the affected thoracic aorta over a longer distance. This might provide a reliable sealing of the entry tear and should prevent further communication between the true lumen and the false lumen.  相似文献   

3.
OBJECTIVE: The aim of this study was to evaluate the feasibility, safety, and effectiveness of endovascular stent-graft placement for the emergency treatment of acute descending thoracic aortic disease. MATERIALS AND METHODS: From January 1996 through November 2001, 18 patients underwent emergency endovascular stent-graft placement for various types of acute descending thoracic aortic disease. Five patients had Stanford type B aortic dissection, six had traumatic ruptures of the thoracic aorta, five had ruptured aortic aneurysms, and two had penetrating atherosclerotic aortic ulcers. All patients presented with life-threatening symptoms requiring treatment with stent-grafts from the emergency kit. All were at high surgical risk due to serious comorbidities. The efficacy of the procedure was assessed at follow-up studies before discharge and at 3, 6, and 12 months after intervention and yearly thereafter. RESULTS: The primary technical success rate was 78%. Four patients had primary perigraft leaks. The secondary technical success rate was 83%. One patient died 20 hr after intervention from stent-graft-related causes. Follow-up studies revealed stent-graft migration in one patient. Progression of disease was observed in one patient treated for dissection and in both patients treated for penetrating ulcers. One patient died 7 months after intervention of unknown reasons; all other patients are alive. The mean follow-up time was 17.4 months (range, 0-38 months). CONCLUSION: Emergency repair of acute descending thoracic aortic disease with stent-graft placement can be successfully accomplished and may be a promising alternative to open-chest surgery, especially in patients at high risk.  相似文献   

4.
Zenith腔内支架移植物治疗腹主动脉瘤   总被引:3,自引:1,他引:2  
目的 评价Zenith跨肾动脉内支架移植物置入术治疗腹主动脉瘤的有效性及安全性。方法 5例腹主动脉瘤患者,均为男性,年龄52~73岁。三维CT造影示4例为Blum B型,1例为Blum C型,瘤颈直径21.0~25、0mm(平均22、8mm),瘤颈长度16.5~32.8mm(平均25.6mm)。于全麻下穿刺股动脉后,在透视下置入内支架移植物,5例均为Zenith分叉型内支架。结果 5例内支架移植物置入均获成功。手术操作时间1、8~3、0h。术后住院7~14d。术后1周行增强CT复查,均无内漏发生。术后2个月及11个月CT复查各1例,均无内漏及内支架移位。5例随诊6.0~55.0个月(平均26.6个月)均无再发。结论 Zenith腔内支架移植物置入术是治疗腹主动脉瘤的一种安全有效的方法。  相似文献   

5.
Descending thoracic aortic diseases: stent-graft repair   总被引:24,自引:0,他引:24  
PURPOSE: To evaluate endovascular treatment of descending thoracic aorta with commercially available self-expanding stent-grafts. MATERIALS AND METHODS: Seventy patients with aortic dissection, intramural hemorrhage, degenerative and posttraumatic aneurysm, penetrating atherosclerotic ulcer, and pseudoaneurysm underwent endovascular treatment. Eleven patients had impending rupture and were treated on an emergency basis. Stent-grafts were customized or selected on the basis of spiral computed tomographic (CT) or magnetic resonance (MR) imaging measurements. Preprocedure diagnostic angiography was performed in patients with aortic dissection and in other selected patients. All procedures were performed in an operating room and monitored with digital subtraction angiography (DSA) and transesophageal echocardiography (TEE). Follow-up was at 1, 3, 6, and 12 months after treatment and yearly thereafter. RESULTS: Stent positioning was technically successful in 68 cases. At DSA and TEE, complete aneurysm or false-lumen exclusion was achieved in 66 (97%) cases. No intraoperative mortality or complications occurred. In-hospital complications included transient monoparesis (one patient) and extension of dissection into ascending aorta (one patient) that was repaired surgically. Early endoleak was observed in five (7%) patients: In three (type 2), endoleak resolved spontaneously; in one (type 1), it was persistent; and in one (type 1), treatment was converted to surgery. At long term, one (1%) patient died of aortic rupture; another, of respiratory insufficiency. Five (7%) late endoleak (type 1, one caused by migration of the stent) cases were observed. In three (4%), endovascular treatment was successful; in two (3%), surgery was performed. In one patient with persistent postimplantation syndrome, treatment was converted to surgery after successful aneurysm sealing. Procedure failure (ie, aortic disease-related mortality or conversion to surgery) occurred in six (9%) patients. CONCLUSION: Endovascular stent-graft repair is less invasive in patients with chronic and acute descending thoracic aortic aneurysm and dissection.  相似文献   

6.
Purpose: To report our experience with stent-graft treatment of acute aortic injuries. Materials and methods: Emergent stent-graft placement was considered in patients with acute aortic rupture or injury who were deemed to be high-risk candidates for surgery. After medical stabilization, patients were evaluated for suitability for endovascular interventions. Anatomic criteria for stent-grafting included: (1) contained ruptures of the thoracic aorta located distal to the left subclavian artery and above the celiac axis, and (2) a proximal and distal neck of ≥ 15 mm in length and ≤ 40 mm in diameter. Stent-grafts consisted of a modified Z-stent endoskeleton covered with woven polyester vascular graft material. All devices were placed under general endotracheal anesthesia. A transfemoral approach was utilized if the iliofemoral artery diameter was ≥ 8 mm. For iliofemoral diameters < 8 mm, the catheters were inserted directly into the infrarenal aorta after a retroperitoneal exposure. Patient follow-up consisted of angiography and spiral CT scan prior to discharge from the hospital. Subsequent spiral CT studies were performed at 6 and 12 months, and at 1-year intervals thereafter. Results: Thirteen patients (11 men and 2 women) with a mean age of 60 years (range 34–81 years) underwent emergent placement of thoracic stent-grafts for acute aneurysmal rupture (n = 8), traumatic transection (n = 3), or tumor and abscess erosions (n = 2). The stent-grafts were deployed successfully in all cases and there were no cases of embolization, paraplegia, or stent-graft migration. No patient required surgical conversion. The average stent-graft dimension was 34 mm in diameter (range 24–38 mm) by 15.8 cm in length (range 5.0–17.5 cm). No patient with traumatic aortic injury was excluded on the basis of anatomic criteria. Two patients died within 1 month of the procedure, one of ventricular rupture and the other of cardiac arrest on day 28 after an uneventful hospital course for a ruptured aneurysm. Conclusion: The preliminary experience from our series demonstrates that aortic stent-grafting for traumatic aortic injury is technically feasible and can be used to treat thoracic aortic rupture in patients at high risk for standard operative therapy.  相似文献   

7.
Over the last 10 years endovascular stent-graft placement has been increasingly used to treat complicated acute Type B thoracic aortic dissections. While studies have demonstrated the use of additional aortic stent-grafts to treat continued false lumen perfusion and case reports have detailed the use of renal artery stents to treat renal ischemia related to aortic dissection, to our knowledge the adjuvant use of renal artery stents to reduce false lumen perfusion has not been reported. We present the case of a 72-year-old male who had previously undergone endovascular repair of a complicated Type B thoracic aortic dissection and presented with an expanding false lumen in the peridiaphragmatic aorta despite coverage of the entire thoracic aorta. This was treated by closure of a right renal fenestration using a renal stent.  相似文献   

8.
AIM: To determine and compare rates of descending aortic enlargement and complications in chronic aortic dissection with and without a proximal aortic graft. METHODS AND MATERIALS: Fifty-two patients with dissection involving the descending aorta and who had undergone at least two computed tomography (CT) examinations at our institution between November, 1993 and February, 2004 were identified, including 24 non-operated patients (four type A, 20 type B) and 28 operated patients (type A). CT examinations per patient ranged from two to 10, and follow-up ranged from 1-123 months (mean 49 months, median 38.5 months). On each CT image, the aortic short axis (SA), false lumen (FL), and true lumen (TL) diameters were measured at the longitudinal midpoint of the dissection and at the point of maximum aortic diameter. Complications were tabulated, including aortic rupture and aortic enlargement requiring surgery. RESULTS: For non-operated patients, the midpoint and maximum point SA, TL, and FL diameters increased significantly over time. For operated patients, the midpoint and maximum point SA and FL diameters increased significantly over time. In both groups, aortic enlargement was predominantly due to FL expansion. Diameter increases in non-operated patients were significantly larger than those in operated patients. The rate of change in aortic diameter was constant, regardless of aortic size. Four non-operated and six operated patients developed aortic complications. CONCLUSIONS: In patients with a dissection involving the descending thoracic aorta, the FL increased in diameter over time, at a constant rate, and to a greater degree in non-operated patients (mostly type B) compared with operated patients (all type A).  相似文献   

9.
带膜支架腔内置入术治疗急性胸腹主动脉夹层   总被引:2,自引:0,他引:2       下载免费PDF全文
目的 :探讨带膜支架腔内置入术治疗急性胸腹主动脉夹层的应用和疗效。方法 :对 1例急性胸腹主动脉多发破口的主动脉夹层采用带膜支架置入治疗 ,并分析其疗效。结果 :经股动脉置入两枚带膜支架封闭破口成功 ,术后复查彩超和多层螺旋CT示主动脉夹层消失 ,假腔内血栓形成 ,未出现支架移位、狭窄等并发症。结论 :带膜支架腔内置入术是治疗主动脉夹层的有效方法。  相似文献   

10.
目的评估覆膜支架治疗术治疗Stanford B型主动脉夹层和降主动脉瘤的安全性和近期疗效。方法2003年3月至2005年9月期间,共29例Stanford B型主动脉夹层和2例降胸主动脉瘤患者接受覆膜支架治疗术,所有患者均有高血压病史,其中急性发病27例.本组采用两种支架(Mdtronic Talent15例,上海微创Aegis 16例),术后采用CTA进行定期随访。结果所有支架均成功按预期定位释放,术后即刻DSA复查显示23例夹层患者近端破裂口完全封闭,2例降主动脉瘤也完全隔离,6例发现有内漏;术后7 d CTA复查发现16例假腔内完全血栓形成,12例近端假腔形成血栓,远端假腔仍开放。结论覆膜支架术治疗Stanford B型主动脉夹层和降主动脉瘤安全、有效,可替代外科手术。但覆膜支架术的确切长期疗效尚待进一步的大样本、前瞻性对照研究才能确定。  相似文献   

11.
Treatment of Acute Aortic Type B Dissection with Stent-Grafts   总被引:3,自引:0,他引:3  
Purpose: To evaluate the feasibility of endoluminal stent-grafts in the treatment of acute type B aortic dissections. Methods: In five patients with acute aortic type B dissections, sealing of the primary intimal tear with an endoluminal stent-graft was attempted. Indication for treatment was aneurysm formation in two patients and persistent pain in three patients. One of the latter also had an unstable dissection flap compromising the ostium of the superior mesenteric artery. The distance from the intimal tear to the left subclavian artery was <0.5 cm in four patients, who had typical type B dissections. In one patient with an atypical dissection the distance from the primary tear to the left subclavian artery was 4 cm. This patient had no re-entry tear. Talent tube grafts (World Medical Manufacturing Cooperation, Sunrise, FL, USA) were used in all patients. Results: Stent-graft insertion with sealing of the primary tear was successful in all patients. The proximal covered portion of the stent-graft was placed across the left subclavian artery in four patients (1× transposition of the left subclavian artery). Left arm perfusion was preserved via a subclavian steal phenomenon in the patients in whom the stent-graft covered the orifice of the left subclavian artery. The only procedural complication we observed was an asymptomatic segmental renal infarction in one patient. In the thoracic aorta thrombosis of the false aortic lumen occurred in all patients. In one patient the false lumen of the abdominal aorta thrombosed after 4 weeks; in the other three patients the status of the abdominal aorta remained unchanged compared with the situation prior to stent-graft insertion. As a late complication formation of a secondary aneurysm of the thoracic aorta was observed at the distal end of the stent-graft 3 months after the primary intervention. This aneurysm was treated by coaxial insertion of an additional stent-graft without complications. Conclusion: Endoluminal treatment of acute type B aortic dissections seems to be an attractive alternative treatment to surgical repair. Thrombosis of the false lumen of the thoracic aorta can be induced if the primary tear is sealed with a stent-graft. This could protect the dissected thoracic aorta from delayed rupture.  相似文献   

12.
PURPOSE: To evaluate the usefulness of thoracic computed tomography (CT) after placement of an endovascular stent-graft for the treatment of descending thoracic aortic aneurysm. MATERIALS AND METHODS: From 1992 to 1996, 85 patients with thoracic aortic aneurysm underwent stent-graft placement. In 63 patients, thoracic CT scans were obtained both before and within 10 days after placement. The CT findings were retrospectively studied, and their clinical effect analyzed. In 20 of 63 patients, long-term follow-up CT findings were also evaluated. RESULTS: After stent-graft placement in the 63 patients, CT demonstrated an increase in pleural effusion in 46 (73%), periaortic changes in 21 (33%), perigraft leak in 13 (21%), atelectasis in six (10%), mural thrombus within the stent-graft in two (3%), and new aortic dissection in one (2%). The mean maximum diameter of the aneurysm was 58.8 mm before and 60.0 mm after stent-graft insertion. Sixty-two (98%) patients were successfully treated until discharge. Interventional procedures were performed to eliminate the leakage into the aneurysm sac in 10 patients with perigraft flow depicted at CT. Other complications were managed conservatively. CONCLUSION: Thoracic CT is useful in the treatment of patients after stent-graft insertion for the management of descending thoracic aortic aneurysm.  相似文献   

13.
PURPOSE: Three recently developed stent-grafts and the Wallstent were compared directly in an ovine animal model with regard to performance and biocompatibility. MATERIALS AND METHODS: Three stent-grafts, the Hemobahn (polytetrafluoroethylene [ePTFE]/nitinol), Wallgraft (polyester/Ni-Co-Ti-steel alloy), and Jostent peripheral stent-graft (balloon-expandable ePTFE/stainless steel), and the Wallstent (Ni-Co-Ti-steel alloy), were implanted in sheep iliac arteries (one type of each stent or stent-graft per animal, n = 8). Pre- and postimplantation luminal diameters were measured for each prosthesis and implantation site. Angiography, intravascular ultrasonography (IVUS), and histomorphometric, histologic, and scanning electron microscopic analyses were performed at 3 months. RESULTS: Early lumen gain, late lumen loss, and patent vessel diameter at angiography were not significantly different. Two stent-grafts had significantly more neointima formation (Hemobahn, 9.88 mm(2) +/- 0.94; Wallgraft, 14.98 mm(2) +/- 0.90) than the other stent-graft (Jostent, 6.52 mm(2) +/- 0.46) and the Wallstent (5.24 mm(2) +/- 0.62; P <.01). Patent lumen area was not significantly different (Hemobahn, 42.57 mm(2) +/- 1.41; Jostent, 39.76 mm(2) +/- 2.04; Wallgraft, 40.22 mm(2) +/- 1.04; Wallstent, 41.64 mm(2) +/- 1.59; P =.57). The Hemobahn had significantly more inflammatory reaction (inflammation score of 0.83 +/- 0.03) than the Jostent (0.58 +/- 0.03), Wallgraft (0.55 +/- 0.04), or Wallstent (0.16 +/- 0.01). Angiography and IVUS demonstrated absence of anastomotic neointima formation. Endothelialization was incomplete and immature for all prostheses. CONCLUSIONS: The stent-grafts caused a greater degree of neointima formation and inflammatory vessel wall reaction than the bare stent. However, these changes did not interfere with patent lumen areas and occurred in the absence of excessive anastomotic neointima formation.  相似文献   

14.
The endoluminal stent-graft represents an attractive and a less invasive technique for treatment of various diseases of the descending thoracic aorta. The purpose of this study was to evaluate the Talent endovascular stent-graft for the treatment of various localized diseases of the descending thoracic aorta. Over a 3-year period, Talent thoracic endografts were placed in 40 patients with a high surgical risk, presenting a localized lesion of the descending thoracic aorta: degenerative aneurysm (n = 13), acute traumatic rupture (n = 11), acute Stanford type B aortic dissection (n = 6), false aneurysm (n = 7), and penetrating atherosclerotic ulcer (n = 3). Fifteen patients (37.5%) were treated as emergencies. The feasibility of endovascular treatment and sizing of the aorta and stent-grafts were determined preoperatively by magnetic resonance angiography (MRA) and intraoperative angiography. Immediate and mid-term technical and clinical success was assessed by clinical and MRA follow-up. Endovascular treatment was completed successfully in all 40 patients, with no conversion to open repair or intraoperative mortality. The mean operative time was 37.5 ± 7 min. The overall 30-day mortality rate was 10% (n = 4), all in emergency cases, for causes not related to the endograft. The primary technical success was 92.5%. The mean follow-up period was 15 ± 5 months. The survival rate was 95% (n = 35). Diminution of the aneurismal size was observed in 47.5% (n = 19). We conclude that endovascular treatment of the various localized diseases of the descending thoracic aorta is a promising, feasible, alternative technique to open surgery in well-selected patients.  相似文献   

15.
Purpose To investigate the long-term outcome and efficacy of emergency treatment of acute aortic diseases with endovascular stent-grafts. Methods From September 1995 to April 2007, 37 patients (21 men, 16 women; age 53.9 ± 19.2 years, range 18–85 years) with acute complications of diseases of the descending thoracic aorta were treated by endovascular stent-grafts: traumatic aortic ruptures (n = 9), aortobronchial fistulas due to penetrating ulcer or hematothorax (n = 6), acute type B dissections with aortic wall hematoma, penetration, or ischemia (n = 13), and symptomatic aneurysm of the thoracic aorta (n = 9) with pain, penetration, or rupture. Diagnosis was confirmed by contrast-enhanced CT. Multiplanar reformations were used for measurement of the landing zones of the stent-grafts. Stent-grafts were inserted via femoral or iliac cut-down. Two procedures required aortofemoral bypass grafting prior to stent-grafting due to extensive arteriosclerotic stenosis of the iliac arteries. In this case the bypass graft was used for introduction of the stent-graft. Results A total of 46 stent-grafts were implanted: Vanguard/Stentor (n = 4), Talent (n = 31), and Valiant (n = 11). Stent-graft extension was necessary in 7 cases. In 3 cases primary graft extension was done during the initial procedure (in 1 case due to distal migration of the graft during stent release, in 2 cases due to the total length of the aortic aneurysm). In 4 cases secondary graft extensions were performed—for new aortic ulcers at the proximal stent struts (after 5 days) and distal to the graft (after 8 months) and recurrent aortobronchial fistulas 5 months and 9 years after the initial procedure—resulting in a total of 41 endovascular procedures. The 30-day mortality rate was 8% (3 of 37) and the overall follow-up was 29.9 ± 36.6 months (range 0–139 months). All patients with traumatic ruptures demonstrated an immediate sealing of bleeding. Patients with aortobronchial fistulas also demonstrated a satisfactory follow-up despite the necessity for reintervention and graft extension in 3 of 6 cases (50%). Two patients with type B dissection died due to mesenteric ischemia despite sufficient mesenteric blood flow being restored (but too late). Two suffered from neurologic complications, 1 from paraplegia and 1 from cerebral ischemia (probably embolic), 1 from penetrating ulcer, and 1 from persistent ischemia of the kidney. Five of 9 (56%) patients with symptomatic thoracic aneurysm demonstrated endoleaks during follow-up and there was an increase in the aneurysm in 1. Conclusion Endovascular treatment is safe and effective for emergency treatment of life-threatening acute thoracic aortic syndromes. Results are encouraging, particularly for traumatic aortic ruptures. However, regular follow-up is mandatory, particularly in the other pathologies, to identify late complications of the stent-graft and to perform appropriate additional corrections as required.  相似文献   

16.
血管内支架置入术治疗Stanford B 型主动脉夹层   总被引:1,自引:0,他引:1       下载免费PDF全文
目的:总结主动脉血管支架置入术治疗Stanford B型主动脉夹层的临床经验。方法:术前对15例Stanford B型主动脉夹层患者进行主动脉全程薄层增强CT扫描及血管成像,以获得主动脉夹层病变解剖学特征。在局麻下行主动脉造影,并与CT结果比较,选取支架血管型号。全麻下切开左股动脉或右股动脉,置入支架血管,封堵原发破口,重复造影检查有无内漏。术后1周及1年行CT随访,观察有无内漏、支架移位和假腔变化。结果:15例均获临床成功。1例见少量近端内漏,未发生其他并发症。CT随访,5例主动脉夹层消失,余者假腔内血栓形成。结论:与传统手术相比,腔内隔绝术治疗Stanford B型主动脉夹层具有创伤小、并发症少、安全性高等优点,近期疗效满意。  相似文献   

17.
Purpose: To present four cases of penetrating ulcer of the descending thoracic aorta treated by transfemoral insertion of an endoluminal stent-graft. Methods: Four patients with penetrating aortic ulcers were reviewed. Three cases were complicated by rupture, false aneurysm, or retrograde dissection. All patients were treated by endovascular stent-graft and were followed by helical computed tomography (CT). Results: Endovascular stent-graft deployment was successful in all patients. However, in one case we observed a perigraft leak that spontaneously disappeared within the first month, and two interventions were needed for another patient. Following treatment, one episode of transient spinal ischemia was observed. The 30-day survival rate was 100%, but one patient died from pneumonia with cardiac failure 34 days after the procedure. In one patient, helical CT performed at 3 months showed a false aneurysm independent of the first ulcer. This patient refused any further treatment and suddenly died at home (unknown cause) after a 6-month follow-up period. Conclusion: Transluminal placement of endovascular stent-grafts for treatment of penetrating ulcers of the descending thoracic aorta appears to be a possible alternative to classical surgery. After treatment, follow-up by CT is essential to detect possible complications of the disease.  相似文献   

18.
PURPOSE: To determine whether endovascular treatment of thoracic aorta conditions can be an effective alternative approach to surgical repair. MATERIAL AND METHODS: July 1997 to February 1999, eighteen patients (16 men and 2 women; 58.6 +/- 14.8 years) presenting with different kinds of descending aorta conditions were selected for the endovascular treatment. All patients exhibited severe comorbid pulmonary and/or cardiovascular medical conditions which increased surgical risk. All implants were performed in the operating room under fluoroscopic and TEE guidance. Clinical and imaging follow-up was performed 1, 3, 6 and 12 months later. RESULTS: The endovascular treatment was successful in 17 cases. No deaths or major complications occurred. No leakage was evident at post-procedure angiography. The patients were discharged after 6 +/- 4 days. MRI or CT study performed before hospital discharge showed aneurysms exclusion in 16 patients. In the four cases of dissection, thrombosis of the false lumen was evident since the first follow-up study. In the group of patients (11 cases) with 6 months follow-up, the diameters of stented aortic segments decreased. No late leakage was observed and thrombosis was complete in all cases. DISCUSSION: The natural history of aortic aneurysms and dissection is progressive toward dilation and aortic rupture. Surgery of descending thoracic aorta is burdened with a mortality of 8-12% in elective cases and over 50% in emergency cases or aortic dissection. The endovascular treatment of aortic conditions was introduced in clinical practice in 1991 and literature data show that it is effective, with lower mortality and morbidity rates than surgical treatment. CONCLUSION: Our results stress the feasibility and effectiveness of endovascular procedure in the treatment of complex thoracic aorta conditions even in high risk patients. Thus, endovascular treatment of thoracic aorta can be considered an effective alternative approach to conventional surgery.  相似文献   

19.
PurposeTo evaluate the effect of renal stent-graft placement on kidney function and size alternation in chronic aortic dissection.Materials and MethodsTwenty-five consecutive patients with chronic aortic dissection after thoracic endovascular aortic repair who underwent renal stent-graft placement between January 2015 and December 2016 were retrospectively reviewed. Forty-three patients with chronic aortic dissection who received thoracic endovascular aortic repair in the same period were reviewed as a control group for kidney volume comparison.ResultsTwenty-five stent-grafts were deployed over 25 renal arteries. Overall renal function was assessed by the slope of the regression line constructed from the plots of creatinine clearance versus time within 2 years after the procedure (–0.2810 vs –0.3146 mL/min–1/mo–1, P = .868), kidney volume at 12 months (129.4 ± 40.9 vs 137.0 ± 44.2 cm2, P = .193) and effective renal plasma flow at 6 months (106.3 ± 46.9 vs 124.4 ± 55.5 mL/min, P = .050) and was not significantly deteriorated. Seven treated patients (87.5%) with a renal artery supplied by a false lumen had a decrease in kidney volume, as did 14 patients (56%) in the control group (P = .206). Three patients with a dissected renal artery (75%) in the stent-graft group had an increase in kidney volume compared with 1 patient (11.1%) in the control group (P = .052).ConclusionsOcclusion of the re-entry tear by a stent-graft in the renal artery remains a safe strategy to promote false lumen thrombosis. The stent-graft poses a potential risk of reducing the kidney volume in kidneys supplied by the false lumen but may provide a positive effect in kidney volume with a concomitant dissected renal artery in chronic aortic dissection.  相似文献   

20.
PURPOSE: To describe a custom bifurcated stent-graft for possible treatment of abdominal aortic aneurysm (AAA). MATERIALS AND METHODS: Five male patients (mean age, 76 +/- 6 years), who had AAA (mean diameter, 4.7 +/- 0.4 cm) and who were considered to be at high risk for conventional surgery, were treated with a custom modular bifurcated stent-graft constructed with bifurcated 24-mm x 12-mm (upper body diameter x iliac limb diameter) Cooley Veri-Soft Woven polyester grafts and Gianturco-R?sch Z stents. The stent-graft body was delivered through 20-22-F sheaths, and the contralateral iliac limb was delivered through a 16-F sheath by means of surgical exposure of the common femoral arteries. A flared distal limb extender (12 mm to 14 mm) was created for one patient to accommodate a large common iliac artery. RESULTS: Stent-grafts were successfully deployed without complications in all five patients. There were no proximal or distal leaks. A lumbar-to-inferior mesenteric artery leak was seen in one patient at 24 hours. At 6-month follow-up, all devices were intact, with complete exclusion and shrinkage of the aneurysm in four of five patients. Aneurysm size remained stable in the one patient with a lumbar-to-inferior mesenteric artery leak. CONCLUSION: A custom, bifurcated stent-graft was utilized for endovascular treatment of AAA. Long-term follow-up is necessary for the device.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号