首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
AIM: We performed a retrospective study of 267 core needle aspiration biopsies in order to estimate the accuracy of CT-guided aspiration core needle biopsies for the diagnosis and subsequent treatment of malignant lymphoma. MATERIALS AND METHODS: Between 1989 and 1999, 267 CT-guided core needle biopsies were performed in 241 patients with either primary or recurrent malignant lymphoma. Patients age ranged from 4--88 years. One hundred and sixty-six (62.2%) nodal and 101 (37.8%) extranodal aspiration biopsies were performed using either 18G or 20G Turner needles. Statistical method used was Chi-square analysis. RESULTS: An accurate histological diagnosis was made in 199 (82.5%) patients, the remaining 42 (17.4%) patients had non-diagnostic CT biopsies. Thirty-seven of them were diagnosed by a surgical biopsy, four by bone marrow biopsy and in one patient by paracentesis. One hundred and seventy-nine patients had non-Hodgkin's lymphoma (NHL) and 62 had Hodgkin's disease (HD); 23 (9.54%) patients underwent repeated CT biopsy which was diagnostic in 17 (73.9%) and non-diagnostic in six (26%). CONCLUSION: CT-guided aspiration core biopsies were sufficient to establish a diagnosis in lymphoproliferative disorders in 82.5% of cases. In the light of this experience we suggest that imaging-guided core needle biopsy be used as the first step in the work up of many patients with lymphoma.  相似文献   

2.
BACKGROUND: Percutaneous cutting needle biopsy of focal liver lesions under CT guidance has established itself as a standard method. The purpose of this study was to evaluate which diagnostic quality can be achieved under guidance of multislice CT (MSCT) and with the use of different needle sizes.METHODS: The data of 163 MSCT-guided core biopsies of focal liver lesions were evaluated. A 16G biopsy needle was used in 121 cases and an 18G needle in 42 cases.RESULTS: The sensitivity, specificity, and accuracy for all biopsies were 93.3, 100.0, and 94.5%. The corresponding values were 97.2, 100.0, and 97.5% for the 16G needle and 78.6, 100.0, and 85.7% for the 18G needle, respectively. A definite histological diagnosis could be obtained in 90.0% of the cases (16G 94.0%, 18G 75.8%). These differences were statistically highly significant. Bleeding complications were recognized in seven biopsies (4.3%). In one patient a fatal bleeding occurred after the biopsy. Median biopsy duration was 27 min.CONCLUSIONS: Core biopsy under MSCT guidance is a fast and very accurate method to obtain a histological diagnosis in focal liver lesions. The usage of a 16G needle in comparison to an 18G needle yielded a significantly higher rate of correct results with regard to differentiation between benign and malignant disease as well as establishing a definite histological diagnosis. For an accurate diagnosis of liver lesions a 16G needle is recommended. After biopsy, the patients have to be closely monitored.  相似文献   

3.
The purpose of this study was to evaluate the safety and precision of MRI-guided biopsies of retroperitoneal space-occupying tumors in an open low-field system. In 30 patients with indistinct retroperitoneal tumors [paraaortic lesion (n=20), kidney (n=2), suprarenal gland (n=3) and pancreas (n=5)] MR-guided biopsies were performed using a low-field system (0.2 T, Magnetom Concerto, Siemens, Germany). For the monitoring of the biopsies T1-weighted FLASH sequences (TR/TE=160/5 ms; 90°) were used in all patients and modified FLASH sequences (TR/TE=160/13 ms; 90°) in ten patients. After positioning of the needle in the tumors 114 biopsy specimens were acquired in coaxial technique with 16-gauge cutting needles (Somatex, Germany). The biopsies were successfully performed in all patients without vascular or organ injuries. The visualization of the aortic blood flow with MRI facilitated the biopsy procedures of paraaortic lesions. The size of the lesions ranged from 1.6 to 7.5 cm. The median distance of the biopsy access path was 10.4 cm. Adequate specimens were obtained in 28 cases (93.3%) resulting in a correct histological classification of 27 lesions (90%). In conclusion, MR-guided biopsies of retroperitoneal lesions using an open low-field system can be performed safely and accurately and is an alternative to CT-guided biopsies.  相似文献   

4.

Objective

The purpose of this study was to investigate retrospectively the clinical procedural performance of CT-guided needle biopsy for retroperitoneal lesions.

Materials and Methods

CT-guided needle biopsy was performed in 74 consecutive patients (M:F = 44:30; mean age, 59.7 years) with retroperitoneal lesions between April 1998 and June 2009. The target lesion ranged from 1.5 to 12.5 cm in size. The biopsy access path ranged from 3.5 to 11.5 cm in depth. A biopsy specimen was obtained using an 18-gauge core needle under a CT or CT-fluoroscopy guidance and with the patient under local anesthesia. The histopathological diagnoses from the biopsies were obtained. The diagnostic confirmation of the subtype of lymphoma was evaluated.

Results

Satisfactory biopsy samples were obtained in 73 (99%) of 74 patients and a pathological diagnosis was made in 70 (95%) of 74 patients. Sixty three lesions were malignant (45 lymphomas, nine primary tumors, nine lymph node metastases) and seven were benign. The subtype of lymphoma was specified in 43 (96%) of 45 patients who were diagnosed with lymphoma. Analysis of the value of CT-guided biopsy in this series indicated 63 true positives, zero false positive, six true negatives and five false negatives. This test had a sensitivity of 93%, a specificity of 100% and an accuracy of 93%. No major complications were seen and minor complications were noted in seven patients (five with local hematomas, two with transient pain at the puncture site).

Conclusion

CT-guided needle biopsy for retroperitoneal lesions is highly practical and useful, and particularly for determining the subtypes in patients with lymphoma.  相似文献   

5.
We reviewed the diagnostic accuracy and complication rates of transthoracic needle biopsy (TNB) with an automated 18-gauge core biopsy needle and gun, using either fluoroscopic or CT guidance. One hundred six lesions were biopsied in 103 patients between 1992 and 1998. Hard-copy images, imaging reports, pathology reports and clinical notes were reviewed. In 3 patients it was not possible to establish the lesion as either malignant or benign from the available follow-up, so these were removed from the analysis of diagnostic accuracy. Adequate samples for histological diagnosis were obtained in 104 of 106 (98 %) biopsies. There were 75 of 85 (88 %) true-positive core biopsies for malignant lesions and a specific cell type was identified in 70 of 85 (82 %) cases. A specific histological diagnosis was obtained in 12 of 18 (66 %) biopsies. There was a 19 % rate of pneumothorax with only 2.4 % requiring drainage. Minor haemoptysis occurred in 3.8 % of procedures. The TNB technique with an automated core biopsy needle provides a high level of diagnostic accuracy, effectively distinguishes cell type in malignancy and provides a definite diagnosis in benign disease more frequently than fine needle aspiration (FNA). There is no increased complication rate compared with FNA. Received: 26 January 1999; Revision received: 1 July 1999; Accepted: 2 July 1999  相似文献   

6.
OBJECTIVE. Our objective was to evaluate the role and safety of sonographically guided percutaneous biopsy in the diagnosis of digestive tract lesions when the lesions are not suitable to biopsy by endoscopy and safely reachable by sonography. MATERIALS AND METHODS. We performed 42 biopsies in 41 patients (age range, 14-81 years; mean age, 57.5 years). We performed biopsies with real-time sonographic guidance using graded compression, with a 3.5-5-MHz microconvex transducer. In 39 biopsies, core specimens were obtained with an 18-gauge automatic needle gun; fine-needle aspiration biopsy was obtained in 28 patients with a 22-gauge needle and in the other four patients with a 21-gauge needle. In the remaining three patients, a coaxial technique with 20- and 22-gauge needles for cytology was used. RESULTS. In 40 (95.2%) of 42 core biopsies performed, a specific diagnosis was obtained. A positive diagnosis was obtained in 16 (45.7%) of 35 fine-needle aspirations. The lesions were located from the pharynx to the sigmoid colon. Twenty-eight patients had malignant lesions, and 13 had benign lesions. Only one serious complication, bile peritonitis, was observed. CONCLUSION. Percutaneous biopsy with sonographic guidance can be used safely and efficiently to diagnose digestive tract lesions that can be visualized on sonography and are not accessible endoscopically.  相似文献   

7.
AIM: To evaluate the diagnostic accuracy of deep face and skull-base computed tomography (CT)-guided core biopsy. MATERIALS AND METHODS: Seventeen patients underwent CT-guided percutaneous core biopsies of deep face and skull-base lesions. One biopsy was repeated due to a non-diagnostic sample so 18 biopsy procedures were evaluated. The 17 lesions were centred within the central skull base (n=2), parapharyngeal (n=3), retropharyngeal spaces (n=4), masticator (n=3), pterygopalatine fossa (n=1), and deep lobe of parotid (n=4). Subzygomatic (n=7), retromaxillary (n=9), suprazygomatic (n=1), and transparotid (n=1) needle approaches were used. The diagnostic accuracy was either assessed by a positive histological result from the operative specimen or based on treatment response and clinical follow-up. RESULTS: No immediate or delayed procedural complications were encountered. A histological diagnosis was obtained in 16 of the 18 biopsies (89% diagnostic yield). The pathological diagnosis was confirmed by surgical excision (5/18 biopsies) and by predicted treatment response or clinical follow-up (10/18 biopsies). Diagnosis could not be confirmed for three of the 18 biopsies. The diagnostic accuracy of core biopsy was 13 of 15 (87%) for all samples. CONCLUSION: CT-guided percutaneous deep face core biopsy is a safe technique with good diagnostic accuracy, allowing diagnosis of benign disease and classification of malignant disease.  相似文献   

8.
目的探讨CT引导下经皮肺穿刺活检对周围型肺部病变的诊断价值及其安全性。方法对58例周围型肺部病变的患者,在CT引导下行经皮肺穿刺活检。结果 58例患者中穿刺标本经组织病理学检查确诊病例48例,确诊率为82.8%,其中恶性肿瘤32例,良性病变16例。术后出现有症状并发症7例,其中咯血2例,气胸4例,高热伴脓胸1例,总发生率为12.1%。结论 CT引导下经皮肺穿刺活检定位准确,成功率高,安全可靠,在周围型肺部病变诊断中具有较高的应用价值。  相似文献   

9.
PURPOSE: This study was performed to evaluate the factors affecting the diagnostic accuracy and rate of complications of CT-guided percutaneous transthoracic needle biopsy of mediastinal masses. MATERIALS AND METHODS: We reviewed 73 consecutive mediastinal biopsies in 70 patients. Final diagnoses were based on a retrospective analysis of surgical outcomes, results of repeat biopsies or findings of imaging and clinical follow-up lasting at least 4 months. Benign and malignant biopsy findings were compared with the final outcomes to determine the diagnostic accuracy of the method. Finally, we analysed the complications. RESULTS: CT-guided percutaneous transthoracic needle biopsy provided adequate samples in 61/73 cases, with a total sample rate of 83.6%. Of these 61 biopsies, 51 yielded a correct diagnosis with specific histological typing, mainly in the case of thymoma and metastasis. Lymphomas were less reliably diagnosed. The overall sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy values were 83.6%, 100%, 100%, 35.3% and 83.6%, respectively. Pneumothorax was the most common complication (5.5%). CONCLUSIONS: CT-guided percutaneous transthoracic needle biopsy is an easy, reliable and safe procedure that obviates the need for exploratory surgery in medically treatable or unresectable cases. It should be the first invasive procedure in the diagnostic workup of mediastinal masses.  相似文献   

10.

Introduction

Biopsy of the musculoskeletal system is useful in the management of bone lesions particularly in oncology but they are often challenging procedures with a significant risk of complications. Computed tomography (CT)-guided needle biopsies may decrease these risks but doubts still exist about their diagnostic accuracy. This retrospective analysis of the experience of a single institution with percutaneous CT-guided biopsy of musculoskeletal lesions evaluates the results of these biopsies for bone lesions either in the appendicular skeleton or in the spine, and defines indications.

Materials and methods

We reviewed the results of 2027 core needle biopsies performed over the past 18 years at the authors’ institution. The results obtained are subject of this paper.

Results

In 1567 cases the correct diagnosis was made with the first CT-guided needle biopsy (77.3% accuracy rate), in 408 cases the sample was not diagnostic and in 52 inadequate. Within 30 days these 408 patients underwent another biopsy, which was diagnostic in 340 cases with a final diagnostic accuracy of 94%. Highest accuracy rates were obtained in primary and secondary malignant lesions. Most false negative results were found in cervical lesions and in benign, pseudotumoral, flogistic, and systemic pathologies. There were 22 complications (18 transient paresis, 3 haematomas, 1 retroperitoneal haematoma) which had no influence on the treatment strategy, nor on patient outcome.

Conclusion

This technique is reliable and safe and should be considered nowadays the gold standard for biopsies of the musculoskeletal system.  相似文献   

11.
PURPOSE: To investigate the diagnostic yield of core needle biopsy in patients with malignant lymphoma. MATERIAL AND METHODS: Computed-tomography-guided core needle biopsies in patients with malignant lymphoma performed in the period 1996 to 2001 were evaluated retrospectively. A biopsy was considered as "fully diagnostic" if a histological diagnosis, including the histologic subtype in the event of malignant lymphoma, was achieved and the clinical course and CT follow-up of at least 6 months confirmed the biopsy results. A biopsy was regarded as "partly diagnostic" if histological work-up defined malignant lymphoma but not the histological subtype, and if histological diagnosis bore therapeutic relevance. Diagnostic yield was correlated with features such as size of specimen, location and depth of the target lesion, and experience of the investigator. RESULTS: 45 biopsies were performed in 40 patients. With respect to definite histopathological diagnosis, 31 biopsies (68.9%) were diagnostic and 14 (31.1%) non-diagnostic. In 4 cases (8.8%), biopsies yielded partly diagnostic results, since therapy could be scheduled after biopsy without final sub-classification. Statistical analysis of biopsy parameters revealed that sample sizes were significantly larger in the diagnostic group. CONCLUSION: CT-guided biopsy can be considered as an alternative for lymphoma diagnosis and should be the first interventional procedure. The most important parameter for diagnostic success is the size of the specimen.  相似文献   

12.
The purpose of this study was to determine ability of cyst aspiration and core biopsy to differentiate malignancies, and benign lesions needing intervention from benign complex cysts in the group of Bosniak 2F and 3 renal cysts. One hundred ninety-nine indeterminate complex renal cysts were biopsied under CT or US guidance using a coaxial system (19-G sheath, 20- or 21-G Chiba or Franseen or 18-G spring biopsy needle). Cytology, amylase, lipase, LDH, fat, protein, urea nitrogen, creatine, and culture and sensitivity were assessed in all patients, histopathology in 116, and flow cytometry in 32. In 179 patients (87.9%) a definitive diagnosis was made; in 20 the specimen was inadequate. Twenty of 28 malignancies were correctly diagnosed (sensitivity 0.71); 27 of 31 benign lesions needing intervention (sensitivity 0.87) and 128 of 140 benign complex cysts (sensitivity 0.91). All inconclusive biopsies were explored revealing six malignancies. There were four CT biopsy misdiagnoses: two renal cell carcinomas; one angiomyolipoma; and one abscess. Guided cyst puncture aspiration and core biopsy significantly altered management of Bosniak 3 and 2F renal cysts obviating surgery or invasive procedures in 70% of the patients with an affirmed diagnosis of benign complex cyst and rendering timely surgical and other interventions in the remaining patients. Long-term follow-up (mean 5.6 years) revealed no further misdiagnosis.  相似文献   

13.
We report our experience with computed tomography (CT)-guided coaxial needle biopsy of deep pelvic lesions by an extraperitoneal approach through the iliopsoas muscle, using a curved needle for difficult-to-reach lesions. We reviewed the records of all patients with pelvic masses who underwent CT-guided percutaneous biopsy via iliopsoas muscle between January 1999 and December 2001. Direct anterior or posterior approach to the lesion was obstructed by bowel, bladder, vessels, or bones in all patients. An 18-gauge guide needle was advanced through the iliopsoas muscle and a 22-gauge Chiba needle was used to perform the biopsy. A custom-tailored curved 22-g needle was used in 17 procedures when the location of the iliac vessels and the slope of the iliac wing obstructed a straight path to the lesion. Fifty-three patients underwent 57 CT-guided needle biopsies during the study period. The lesions comprised obturator (n = 25), internal iliac (n = 11), anterior external iliac (n = 4), and common iliac nodes (n = 4); soft tissue masses along pelvic side-wall (n = 6); adnexal lesions (n = 5); a loculated fluid collection, and a perirectal node. All lesions were safely accessed, and major vessels and viscera were avoided in all cases. Of the 57 biopsies, 53 (93%) yielded diagnostic specimens. No major complications were encountered. CT-guided coaxial needle biopsy by an anterolateral approach through the iliopsoas muscle, with the use of a curved needle in selected cases is safe and effective for obtaining samples from deep pelvic lesions. This work was presented at the 2002 Cardiovascular Interventional Society of Europe annual meeting.  相似文献   

14.
PURPOSE: To evaluate the safety and feasibility of computed tomographic (CT)-guided coaxial fine-needle aspiration biopsy (FNAB) of masses in or around the head of the pancreas with a posterior approach that transgresses the inferior vena cava (IVC). MATERIALS AND METHODS: The authors retrospectively reviewed the records of 29 patients with lesions located within (n = 24) or around (n = 5) the pancreatic head who underwent CT-guided FNAB with the posterior transcaval route due to obstruction of the anterior approach by bowel, liver, and/or other structures. A coaxial needle technique was used, with an outer 18-gauge needle positioned posterior to the IVC and an inner 22-gauge needle traversing the IVC to obtain a biopsy of each lesion. All biopsy specimens were subjected to cytologic evaluation. Medical records of all patients were evaluated for complications. RESULTS: All lesions were safely accessed with the posterior transcaval approach without major complications. The biopsies revealed a malignant process in 21 patients, benign pancreatic cysts in two patients, and pancreatitis in one patient. There were five false-negative biopsy results. Minor complications occurred in four patients (small retroperitoneal hematomas occurred in three and abdominal pain occurred in one). CONCLUSION: CT-guided coaxial FNAB by means of a posterior transcaval approach is a safe method for obtaining samples from lesions in or around the pancreatic head.  相似文献   

15.
Objectives Although large lesions of the limbs can easily be biopsied without image guidance, lesions in the spine, paraspinal area and pelvis are difficult to target, and benefit from CT guidance to improve the accuracy of targeting the lesion for biopsy purposes. A prospective study of CT-guided core needle biopsies for deep-seated musculoskeletal lesions was conducted at a referral cancer institute over a 4-year period with the aim of assessing the safety and efficacy of the procedure. Patients & methods From January 2000 to December 2003, 136 consecutive CT-guided biopsy sessions were undertaken for musculoskeletal lesions in 128 patients comprising 73 males and 55 females. The following data was recorded in all patients: demographic data, suspected clinicoradiological diagnosis, data related to core biopsy session (date, site, approach, total time required in minutes, number of cores, surgeon satisfaction with adequacy of cores), patient discomfort, complications, histopathology report and number of further sessions if material obtained during the first biopsy session was not confirmatory. The sample obtained during the biopsy session was considered inconclusive if, in the opinion of the pathologist, inadequate or non-representative tissue had been obtained. The diagnosis was considered inaccurate if the final histopathological diagnosis did not match with the biopsy diagnosis, or if subsequent clinicoradiological evaluation at follow up did not correlate with the biopsy diagnosis in those patients who were treated with modalities other than surgery. Results In 121 patients, a single session was sufficient to obtain representative material, whilst for six patients two sessions, and for one patient three sessions were necessary. The time taken for biopsy, including the pre-biopsy CT examination time, varied from 15 min to 60 min (median 30 min). For 110 bony lesions 116 sessions were required, and for 18 soft-tissue lesions 20 sessions were required. 108 biopsy sessions yielded a diagnosis, whilst 28 were inconclusive (diagnostic yield of 79.41%). Of 108 diagnostic biopsies, five were considered inaccurate (accuracy rate of 95.37%). The overall diagnostic yield and accuracy rate for bony lesions were 81.03% and 95.74%; and those for soft-tissue lesions were 70% and 92.85%. There were two complications with no permanent sequelae. Conclusion CT-guided core needle biopsy is a safe, easy, and effective technique for the evaluation of deep-seated musculoskeletal lesions, with a high rate of diagnostic yield and accuracy. It facilitates definitive therapy without the patient having to undergo a major surgical procedure for diagnosis.  相似文献   

16.
PURPOSE: The growing use of highly sensitive but only moderate specific breast MRI requires the development of both minimal-invasive as well as precise biopsy systems. The aim of the study was to prove the accuracy and feasibility of a biopsy procedure carried out in prone position in a vertically opened MR imager. MATERIALS AND METHODS: The biopsies were carried out in 21 women with lesions visible on MRI alone using an open breast coil with an integrated biopsy device. A 14 G coaxial needle was placed under near real-time MRI-guidance. After the tip of this needle was verified in contact with the lesion, we used a non MR-compatible, but MR-safe biopsy gun with a 16 G canula to take four to eight cores. RESULTS: We found eight malignant and 12 benign lesions. In one patient the procedure was not successful. In case of malignancy, the operation confirmed the diagnosis in all cases. The 12/21 patients with benign lesions have been followed without evidence of lesions growth over eight to 28 months. CONCLUSION: The described procedure allows MRI-guided minimal invasive core biopsy of small breast lesions (five to 17 mm) with a high degree of accuracy.  相似文献   

17.

Purpose

The aim of was study was to evaluate the accuracy of computed tomography (CT)-guided core needle biopsy (CNB) performed by modified coaxial technique as an alternative tool to surgical biopsy in patients with suspected malignant lymphoma.

Materials and methods

Between May 2005 and December 2008, 67 CT-guided CNB of deep lesions were performed on 64 patients with suspected malignant lymphoma. In 19 out of 64 patients (29.7%), recurrent lymphoma was suspected. A modified coaxial technique was used in all cases, and multiple samples were obtained for histological and immunohistochemical studies.

Results

A diagnosis of malignant lymphomas with specification of subtype according to the World Health Organization (WHO) classification was established in 41/67 cases. Other malignant neoplasms were found in 13/67, lymphoma without subtype specification was diagnosed in 7/67, whereas no conclusive diagnosis could be established in 6/67 cases. Overall diagnostic accuracy was 80.1%. In patients with a final diagnosis of malignant lymphoma, accuracy was 75.9%. No complications occurred.

Conclusions

Percutaneous CT-guided CNB is a safe, effective and reliable tool in the management of lymphomas in patients without superficial lymphadenopathy and can be considered an alternative approach to surgical sampling. The modified coaxial technique represents an effective tool that has a good diagnostic accuracy value with a low complication rate.  相似文献   

18.
目的 探讨CT引导下经皮穿刺活检在原因不明腹膜病变的诊断价值.方法 回顾性分析84例腹膜增厚原因待查患者,其中男26例,女58例,均行CT引导下经皮腹膜穿刺活检.结果 84例腹膜穿刺病理诊断为恶性病变60例(71.4%),包括55例腹膜转移肿瘤,4例恶性间皮瘤,1例淋巴瘤;非恶性病变24例(28.6%),包括11例结核病变,13例炎性病变.3例未作出明确病理诊断,临床资料失访.穿刺活检正确率为91.7%(77/84).并发症为1例出血和2例腹水外渗.结论 CT引导下经皮腹膜穿刺活检是一种安全有效的方法,为临床治疗提供依据.  相似文献   

19.
CT导向下经皮针刺活检前纵隔肿瘤   总被引:1,自引:0,他引:1  
目的 探讨经皮针刺活检前纵隔肿瘤的影响穿刺准确性的因素。资料与方法 回顾性分析 80例前纵隔肿瘤CT导向下经皮针刺活检术。结果  (1)病理学明确诊断 6 7例 ,不能确定诊断 13例 ;(2 )细针抽吸、切割针活检穿刺敏感性分别为 75 %、90 .5 % ;(3) 16例小病灶穿刺敏感性为 6 8.8% ,6 4例大病灶穿刺敏感性为 87.5 % ;(4)胸腺类肿瘤、淋巴结转移性癌活检准确性均为 92 % ,淋巴瘤活检准确性仅为 6 5 % ,与前两组比较有统计学意义(P <0 .0 5 ) ;(5 )穿刺并发症发生率为 7.5 %。结论 切割针活检阳性率高于细针活检 ,活检阳性率大病灶高于小病灶 ,胸腺类肿瘤、淋巴结转移性癌活检阳性率显著高于淋巴瘤 ;CT导向下经皮针刺活检术是前纵隔肿瘤安全、有价值的诊断方法。  相似文献   

20.
CT导引四肢骨活检的价值(附50例报告)   总被引:3,自引:0,他引:3  
目的 报告应用CT导引活检在四肢骨病变诊断中的方法和作用。方法 对 5 0例四肢骨病变行CT导引下活检。每例常规取样 2~ 3次。对 13例灶区或灶周硬化明显者应用了Ackmann骨钻针 ,对 42例应用了Temno核心切割针 ,12例囊性或有明显液化区的病灶则加用了细抽吸针。结果 活检的诊断准确率 88%( 4 4/5 0 )。 6例假阴性者的病灶特征包括 3例增生硬化性病灶 ,2例液化性及 1例混合性病灶。 5 0例可以分为原发恶性骨肿瘤 (n =2 3) ,原发良性骨肿瘤及肿瘤样病变 (n =12 ) ,骨转移 (n =8)及骨感染 (n =7)四类 ,其活检准确率分别为 91%、83%、10 0 %和 71%。Ackmann骨钻针、Temno核心切割针及细抽吸针的活检准确率分别为6 2 %、83%和 5 8%。未发生严重并发症。结论 CT导引下四肢骨活检是一种安全、准确而有效的方法。根据病变类型选用骨钻针、核心切割针或细抽吸针 ,并注意避开坏死区及多靶点取样 ,三种活检针的取样结果有互补性 ,合理联合使用可以提高诊断准确率。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号