首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
ObjectivesThe aim of this study was to evaluate the impact of intravascular ultrasound (IVUS) guidance on the final volume of contrast agent used in patients undergoing percutaneous coronary intervention (PCI).BackgroundTo date, few approaches have been described to reduce the final dose of contrast agent in PCIs. We hypothesized that IVUS might serve as an alternative imaging tool to angiography in many steps during PCI, thereby reducing the use of iodine contrast.MethodsA total of 83 patients were randomized to angiography-guided PCI or IVUS-guided PCI; both groups were treated according to a pre-defined meticulous procedural strategy. The primary endpoint was the total volume contrast agent used during PCI. Patients were followed clinically for an average of 4 months.ResultsThe median total volume of contrast was 64.5 ml (interquartile range [IQR]: 42.8 to 97.0 ml; minimum, 19 ml; maximum, 170 ml) in the angiography-guided group versus 20.0 ml (IQR: 12.5 to 30.0 ml; minimum, 3 ml; maximum, 54 ml) in the IVUS-guided group (p < 0.001). Similarly, the median volume of contrast/creatinine clearance ratio was significantly lower among patients treated with IVUS-guided PCI (1.0 [IQR: 0.6 to 1.9] vs. 0.4 [IQR: 0.2 to 0.6, respectively; p < 0.001). In-hospital and 4-month outcomes were not different between patients randomized to angiography-guided and IVUS-guided PCI.ConclusionsThoughtful and extensive use of IVUS as the primary imaging tool to guide PCI is safe and markedly reduces the volume of iodine contrast compared with angiography-alone guidance. The use of IVUS should be considered for patients at high risk of contrast-induced acute kidney injury or volume overload undergoing coronary angioplasty. (Minimizing cOntrast utiliZation With IVUS Guidance in coRonary angioplasTy [MOZART]; NCT01947335)  相似文献   

2.
ObjectivesThis study used a fractal bifurcation bench model to compare 6 optimization sequences for coronary bifurcation provisional stenting, including 1 novel sequence without kissing balloon inflation (KBI), comprising initial proximal optimizing technique (POT) + side-branch inflation (SBI) + final POT, called “re-POT.”BackgroundIn provisional bifurcation stenting, KBI fails to improve the rate of major adverse cardiac events. Proximal geometric deformation increases the rate of in-stent restenosis and target lesion revascularization.MethodsA bifurcation bench model was used to compare KBI alone, KBI after POT, KBI with asymmetric inflation pressure after POT, and 2 sequences without KBI: initial POT plus SBI, and initial POT plus SBI with final POT (called “re-POT”). For each protocol, 5 stents were tested using 2 different drug-eluting stent designs: that is, a total of 60 tests.ResultsCompared with the classic KBI-only sequence and those associating POT with modified KBI, the re-POT sequence gave significantly (p < 0.05) better geometric results: it reduced SB ostium stent-strut obstruction from 23.2 ± 6.0% to 5.6 ± 8.3%, provided perfect proximal stent apposition with almost perfect circularity (ellipticity index reduced from 1.23 ± 0.02 to 1.04 ± 0.01), reduced proximal area overstretch from 24.2 ± 7.6% to 8.0 ± 0.4%, and reduced global strut malapposition from 40 ± 6.2% to 2.6 ± 1.4%.ConclusionsIn comparison with 5 other techniques, the re-POT sequence significantly optimized the final result of provisional coronary bifurcation stenting, maintaining circular geometry while significantly reducing SB ostium strut obstruction and global strut malapposition. These experimental findings confirm that provisional stenting may be optimized more effectively without KBI using re-POT.  相似文献   

3.
ObjectivesThe aim of this study is to compare the relative merits of optical coherence tomography (OCT), intravascular ultrasound (IVUS), and near infrared spectroscopy (NIRS) in patients with coronary artery disease for the prediction of periprocedural myocardial infarction (MI).BackgroundAlthough several individual intravascular imaging modalities have been employed to predict periprocedural MI, it is unclear which of the imaging tools would best allow prediction of this complication.MethodsWe retrospectively analyzed 110 patients who underwent OCT, IVUS, and NIRS. Periprocedural MI was defined as a post-procedural cardiac troponin I (cTnI) elevation above 3× the upper limit of normal; analysis was also performed for cTnI ≥5× the upper limit of normal.ResultscTnI ≥3× was observed in 10 patients (9%) and 8 patients had cTnI ≥5×. By OCT, minimum cap thickness was significantly lower (55 vs. 90 μm, p < 0.01), and the plaque burden by IVUS (84 ± 9% vs. 77 ± 8%, p < 0.01) and maximum 4-mm lipid core burden index by NIRS (556 vs. 339, p < 0.01) were greater in the cTnI ≥3× group. Multivariate logistic regression analysis identified cap thickness as the only independent predictor for cTnI ≥3× the upper limit of normal (odds ratio [OR]: 0.90, p = 0.02) or cTnI ≥5× (OR: 0.91, p = 0.04). If OCT findings were excluded from the analysis, plaque burden (OR: 1.13, p = 0.045) and maximum 4-mm lipid core burden index (OR: 1.003, p = 0.037) emerged to be the independent predictors.ConclusionsOCT-based fibrous cap thickness is the most important predictor of periprocedural MI. In the absence of information about cap thickness, NIRS lipid core or IVUS plaque burden best determined the likelihood of the periprocedural event.  相似文献   

4.
ObjectivesThis study sought to investigate the in-scaffold vascular response (SVR) and edge vascular response (EVR) after implantation of an everolimus-eluting bioresorbable scaffold (BRS) using serial optical coherence tomography (OCT) imaging.BackgroundAlthough studies using intravascular ultrasound have evaluated the EVR in metal stents and BRSs, there is a lack of OCT-based SVR and EVR assessment after BRS implantation.MethodsIn the ABSORB Cohort B (ABSORB Clinical Investigation, Cohort B) study, 23 patients (23 lesions) in Cohort B1 and 17 patients (18 lesions) in Cohort B2 underwent truly serial OCT examinations at 3 different time points (Cohort B1: post-procedure, 6 months, and 2 years; B2: post-procedure, 1 year, and 3 years) after implantation of an 18-mm scaffold. A frame-by-frame OCT analysis was performed at the 5-mm proximal, 5-mm distal edge, and 2-mm in-scaffold margins, whereas the middle 14-mm in-scaffold segment was analyzed at 1-mm intervals.ResultsThe in-scaffold mean luminal area significantly decreased from baseline to 6 months or 1 year (7.22 ± 1.24 mm2 vs. 6.05 ± 1.38 mm2 and 7.64 ± 1.19 mm2 vs. 5.72 ± 0.89 mm2, respectively; both p < 0.01), but remained unchanged from then onward. In Cohort B1, a significant increase in mean luminal area of the distal edge was observed (5.42 ± 1.81 mm2 vs. 5.58 ± 1.53 mm2; p < 0.01), whereas the mean luminal area of the proximal edge remained unchanged at 6 months. In Cohort B2, the mean luminal areas of the proximal and distal edges were significantly smaller than post-procedure measurements at 3 years. The mean luminal area loss at both edges was significantly less than the mean luminal area loss of the in-scaffold segment at both 6-month and 2-year follow-up in Cohort B1 or at 1 year and 3 years in Cohort B2.ConclusionsThis OCT-based serial EVR and SVR evaluation of the Absorb Bioresorbable Vascular Scaffold (Abbott Vascular, Santa Clara, California) showed less luminal loss at the edges than luminal loss within the scaffold. The luminal reduction of both edges is not a nosologic entity, but an EVR in continuity with the SVR, extending from the in-scaffold margin to both edges. (ABSORB Clinical Investigation, Cohort B [ABSORB B]; NCT00856856)  相似文献   

5.
ObjectivesThe purpose of this study was to evaluate 15-year patency and life expectancy after endovascular treatment (EVT) with primary stenting guided by intravascular ultrasound (IVUS) for iliac artery lesions.BackgroundFifteen-year patency, factors causing restenosis, and survival after IVUS-guided EVT are unclear based on the TransAtlantic Inter-Society Consensus II (TASC-II) classification in peripheral arterial disease (PAD).MethodsEVT was performed for 507 lesions in 455 patients with PAD. The 15-year endpoints were primary, primary-assisted, and secondary patency; overall survival; freedom from major adverse cardiovascular events (MACE); and freedom from major adverse cardiovascular and limb events (MACLE).ResultsThe 5-, 10-, and 15-year primary and secondary patencies were 89%, 83%, and 75%, respectively, and 92%, 91%, and 91%, respectively. There were no significant differences among TASC-II categories.ConclusionsIVUS-guided stenting for the iliac artery had favorable 15-year patency in all TASC categories. Life expectancy after EVT was poor, but stenting is feasible for patients with PAD.  相似文献   

6.
ObjectivesThis study aimed to investigate the characteristics of neoatherosclerosis (NA) in patients with diabetes mellitus (DM) after drug-eluting stent (DES) implantation using optical coherence tomography.BackgroundNA is an important substrate for stent failure. In vivo NA characteristics in DM patients have not been investigated.MethodsA total of 397 patients with 452 DES who underwent follow-up optical coherence tomography examination after DES implantation were enrolled. Characteristics of NA were compared between DM and non-DM patients. Neovascularization was defined as signal-poor holes or tubular structures with a diameter of 50 to 300 μm.ResultsA total of 123 DES with NA lesions in 115 patients were identified. The incidence of NA was similar between DM and non-DM patients (29.6% vs. 28.6%; p = 0.825). Compared with the non-DM group, neovascularization was more frequently observed in the DM group (55.1% vs. 32.4%; p = 0.012). The multivariate logistic model demonstrated that DM (odds ratio: 3.00; 95% confidence interval: 1.31 to 6.81; p = 0.009) and follow-up duration (odds ratio: 1.03; 95% confidence interval: 1.02 to 1.05; p < 0.001) were the independent predictors for neovascularization in NA lesions. DM patients with glycated hemoglobin ≥7.0% had a higher prevalence of thin-cap fibroatheroma compared with those with glycated hemoglobin <7.0% (40.0% vs. 8.3%; p = 0.01).ConclusionsThe incidence of NA was similar between patients with and without DM. Neovascularization in NA lesions was more frequent in those with DM. Poorly controlled DM patients had a higher incidence of thin-cap fibroatheroma, compared with those with well-controlled DM.  相似文献   

7.
ObjectivesThe intention this PEPCAD-DES (Treatment of Drug-eluting Stent [DES] In-Stent Restenosis With SeQuent Please Paclitaxel Eluting Percutaneous Transluminal Coronary Angioplasty [PTCA] Catheter) study update was to demonstrate the safety and efficacy of paclitaxel-coated balloon (PCB) angioplasty in patients with DES-ISR at 3 years.BackgroundIn the PEPCAD-DES trial late lumen loss and the need for repeat target lesion revascularization (TLR) was significantly reduced with PCB angioplasty compared with plain old balloon angioplasty (POBA) in patients with drug-eluting stent in-stent restenosis (DES-ISR) at 6 months. We evaluated whether the clinical benefit of reduced TLR and major adverse cardiac events (MACE) was maintained up to 3 years.MethodsA total of 110 patients with DES-ISR in native coronary arteries with reference diameters ranging from 2.5 mm to 3.5 mm and lesion lengths ≤22 mm were randomized to treatment with either PCB or POBA in a multicenter, randomized, single-blind clinical study. With a 2:1 randomization, 72 patients were randomized to the PCB group and 38 patients to the POBA group. At baseline, there were lesions with at least 2 stent layers in PCB (52.8%, 38 of 72) and POBA (55.3%, 21 of 38) patients.ResultsAt 36 months, the TLR rates were significantly lower in the PCB group compared with the POBA control group (19.4% vs. 36.8%; p = 0.046). Multiple TLRs in individual patients were more frequent in the POBA group compared with the PCB group (more than 1 TLR: POBA, 13.2%; PCB, 1.4%; p = 0.021). The 36-month MACE rate was significantly reduced in the PCB group compared with the POBA group (20.8% vs. 52.6%, log-rank p = 0.001).ConclusionsPCB angioplasty was superior to POBA for the treatment of DES-ISR patients in terms of MACE and TLR for up to 36 months. There was no late catch-up phenomenon. (Treatment of Drug-eluting Stent [DES] In-Stent Restenosis With SeQuent® Please Paclitaxel Eluting Percutaneous Transluminal Coronary Angioplasty [PTCA] Catheter [PEPCAD-DES]; NCT00998439)  相似文献   

8.
ObjectivesThis study sought to evaluate the intravascular ultrasound (IVUS) minimal lumen area (MLA) for functionally significant left main coronary artery (LMCA) stenosis using fractional flow reserve (FFR) as the standard.BackgroundThe evaluation of significant LMCA stenosis remains challenging.MethodsWe identified 112 patients with isolated ostial and shaft intermediate LMCA stenosis (angiographic diameter stenosis of 30% to 80%) who underwent IVUS and FFR measurement.ResultsThe FFR was ≤0.80 in 66 LMCA lesions (59%); these exhibited smaller reference vessels, smaller minimal lumen diameter, greater diameter of stenosis, longer lesion length, smaller MLA, larger plaque burden, and more frequent plaque rupture. The independent factors of an FFR of ≤0.80 were plaque rupture (odds ratio [OR]: 4.47; 95% Confidence Interval (CI): 1.35 to 14.8; p = 0.014); body mass index (OR: 1.19; 95% CI: 1.00 to 1.41; p = 0.05), age (OR: 0.95; 95% CI: 0.90 to 1.00; p = 0.031), and IVUS MLA (OR: 0.37; 95% CI: 0.25 to 0.56; p < 0.001). The optimal IVUS MLA cutoff value for an FFR of ≤0.80 was 4.5 mm2 (77% sensitivity, 82% specificity, 84% positive predictive value, 75% negative predictive value, area under the curve: 0.83, 95% CI: 0.76 to 0.96; p < 0.001) overall and 4.1 to 4.5 mm2 in various subgroups. Adjustment for the body surface area, body mass index, and left ventricular mass did not improve the diagnostic accuracy of the IVUS MLA.ConclusionsIn patients with isolated ostial and shaft intermediate LMCA stenosis, an IVUS-derived MLA of ≤4.5 mm2 is a useful index of an FFR of ≤0.80.  相似文献   

9.
ObjectivesThe study aimed to evaluate the adequacy and feasibility of the single string bifurcation stenting technique.BackgroundDouble-stent techniques may be required for complex bifurcations. Currently applied methods all have their morphological or structural limitations with respect to wall coverage, multiple strut layers, and apposition rate.MethodsSingle string is a novel method in which, first, the side branch (SB) stent is deployed with a single stent cell protruding into the main branch (MB). Second, the MB stent is deployed across this protruding stent cell. The procedure is completed by final kissing balloon dilation. The single string technique was first tested in vitro (n = 20) and next applied in patients (n = 11) with complex bifurcation stenoses.ResultsAll procedures were performed successfully, crossing a single stent cell in 100%. Procedure duration was 23.0 ± 7.9 min, and the fluoroscopy time was 9.4 ± 3.5 min. The results were evaluated by optical coherence tomography, showing fully apposed struts in 83.0 ± 9.2% in the bifurcation area. Residual area obstruction in the MB was 6.4 ± 5.6% and 25.0 ± 16.9% in the SB, as evaluated by micro computed tomography. All the human cases were performed successfully with excellent angiographic results: the residual area stenosis was 27 ± 8% and 29 ± 10% in the MB and in the SB, respectively, by 3-dimensional quantitative coronary angiography. No relevant periprocedural enzyme increase was observed. During follow-up (6 ± 4 months), no adverse clinical events (death, myocardial infarction, target vessel revascularization) were noted.ConclusionsThe single string technique for complex bifurcation dilation was shown to be adequate in vitro and feasible in humans, with favorable results in terms of stent overlap, malapposition rate, and low residual obstruction in both the MB and SB.  相似文献   

10.
ObjectivesThis study sought to compare the outcomes of fractional flow reserve (FFR)–guided and angiography (Angio)–guided provisional side-branch (SB) stenting for true coronary bifurcation lesions.BackgroundAngio-guided provisional SB stenting after stenting of the main vessel provides favorable outcomes for the majority of coronary bifurcation lesions. Whether an FFR-guided provisional stenting approach is superior has not been studied.MethodsA total of 320 patients with single Medina 1,1,1 and 0,1,1 coronary bifurcation lesions undergoing stenting with a provisional SB approach were randomly assigned 1:1 to Angio-guided and FFR-guided groups. SB stenting was performed for Thrombolysis In Myocardial Infarction flow grade <3, ostial SB stenosis >70%, or greater than type A dissection after main vessel stenting in the Angio-guided group and for SB-FFR <0.80 in the FFR-guided group. The primary endpoint was the 1-year composite rate of major adverse cardiac events (cardiac death, myocardial infarction, and clinically driven target vessel revascularization).ResultsComparing the Angio-guided and FFR-guided groups, treatment of the SB (balloon or stenting) was performed in 63.1% and 56.3% of lesions respectively (p = 0.07); stenting of the SB was attempted in 38.1% and 25.9%, respectively (p = 0.01); and, when attempted, stenting was successful in 83.6% and 73.3% of SBs, respectively (p = 0.01). The 1-year composite major adverse cardiac event rate was 18.1% in both groups (hazard ratio: 0.91, 95% confidence interval: 0.48 to 1.88; p = 1.00). The 1-year target vessel revascularization and stent thrombosis rates were 6.9% and 5.6% (p = 0.82) and 1.3% and 0.6% (p = 0.56) in the Angio-guided and FFR-guided groups, respectively.ConclusionsIn this multicenter, randomized trial, angiographic and FFR guidance of provisional SB stenting of true coronary bifurcation lesions provided similar 1-year clinical outcomes. (Randomized Study on DK Crush Technique Versus Provisional Stenting Technique for Coronary Artery Bifurcation Lesions; ChiCTR-TRC-07000015)  相似文献   

11.
ObjectivesThe aim of this study was to investigate the correlation between in-stent neointimal tissue without features of neoatherosclerosis and long-term clinical outcomes.BackgroundRecent studies have reported differential morphological characteristics of in-stent neointimal tissue assessed by optical coherence tomography (OCT).MethodsThe study population consisted of 336 patients with 368 drug-eluting stent-treated lesions. Patients received a follow-up OCT examination without any intervention. OCT-based neointima was categorized as homogeneous (n = 227 lesions in 208 patients), heterogeneous (n = 79 lesions in 73 patients), or layered (n = 62 lesions in 55 patients). Major adverse cardiac events (MACE) (a composite of cardiac death, nonfatal myocardial infarction, or target lesion revascularization) were assessed according to neointimal patterns during long-term clinical follow-up after OCT examination.ResultsThe time interval between stent implantation and OCT examination was similar among the 3 groups (p = 0.64). On multivariate logistic regression analysis, the significant determinant for the heterogeneous neointima was age (odds ratio [OR]: 1.037, 95% confidence interval [CI]: 1.007 to 1.068, p = 0.015) and an initial clinical presentation of acute coronary syndrome (OR: 1.967, 95% CI: 1.159 to 3.339, p = 0.012). The overall median follow-up duration for all patients after follow-up OCT examination was 31.0 months, and this was statistically different among the heterogeneous group (22.0 months), the homogeneous group (34.0 months), and the layered group (28.0 months, overall p = 0.002). MACE occurred more frequently in patients with heterogeneous neointima over a median 31-month follow-up period after OCT examination (13.7% vs. 2.9% in homogeneous vs. 7.3% in layered, p = 0.001). A propensity score–adjusted Cox regression analysis showed that independent risk factors for MACE were inclusion in the heterogeneous neointima (hazard ratio: 3.925, 95% CI: 1.445 to 10.662, p = 0.007) and minimal lumen cross-sectional area (hazard ratio: 0.368, 95% CI: 0.242 to 0.560, p < 0.001).ConclusionsDetermination of neointimal characteristics is helpful in predicting long-term clinical outcomes. Our data suggest that heterogeneous lesions are linked to poor long-term clinical prognoses.  相似文献   

12.
ObjectivesThe aim of this study was to examine the efficacy and bleeding outcomes of cangrelor in patients in the CHAMPION PHOENIX (A Clinical Trial Comparing Cangrelor to Clopidogrel Standard Therapy in Subjects Who Require Percutaneous Coronary Intervention [PCI]) who underwent percutaneous coronary intervention with bivalirudin.BackgroundCangrelor is a potent intravenous P2Y12 inhibitor with rapid onset and offset. In the CHAMPION PHOENIX, cangrelor compared with clopidogrel significantly reduced 48-h ischemic events including stent thrombosis, without increasing major bleeding. Bivalirudin has demonstrated ischemic outcomes similar to those with heparin plus glycoprotein IIb/IIIa inhibition, with reduced bleeding but increased early stent thrombosis.MethodsIn the modified intent-to-treat population, 2,059 patients (18.8%) received bivalirudin, with 1,014 patients in the cangrelor treatment arm and 1,045 in the clopidogrel treatment arm.ResultsAt 48 h, the primary endpoint of death, myocardial infarction, ischemia-driven revascularization, or stent thrombosis was lower with cangrelor versus clopidogrel (48 [4.7%] vs. 70 [6.7%]; odds ratio [OR]: 0.68, p = 0.047). Death was similar in both arms (2 [0.2%] vs. 2 [0.2%]). Myocardial infarction was reduced by cangrelor (37 [3.6%] vs. 59 [5.6%]; OR: 0.63, p = 0.03), as was death/myocardial infarction (39 [3.8%] vs. 61 [5.8%]; OR: 0.65, p = 0.04). Cangrelor was associated with a nonsignificant trend toward less stent thrombosis (7 [0.7%] vs. 15 [1.4%]; OR: 0.48, p = 0.10), which was evident within 2 h after percutaneous coronary intervention (p = 0.057). GUSTO (Global Use of Strategies to Open Occluded Arteries) severe bleeding was similar in both arms (2 of 1,021 [0.2%] vs. 2 of 1,055 [0.2%]) as were other bleeding definitions and transfusions. Efficacy and safety results were consistent in patients with stable angina, non–ST-segment elevation acute coronary syndrome, and ST-segment elevation myocardial infarction (p for interaction: 0.62 and 0.29).ConclusionsCangrelor may offer an attractive benefit risk profile when used in combination with bivalirudin.  相似文献   

13.
ObjectivesThis study sought to compare the outcomes of spot stenting versus long stenting after intentional subintimal approach for long femoropopliteal chronic total occlusions (CTO).BackgroundThe optimal stenting strategy following the subintimal recanalization of long femoropopliteal chronic total occlusions has not been investigated.MethodsA total of 196 limbs in 163 patients, implanted with bare nitinol stents after subintimal approach in long femoropopliteal occlusions (lesion length 25 ± 8 cm), were retrospectively analyzed. The primary patency was compared between spot stenting (n = 129) and long stenting (n = 67).ResultsBaseline characteristics and immediate procedural results were similar between groups. Adjusted-primary patency (47% vs. 77%, p < 0.001) and adjusted-freedom from target lesion revascularization (52% vs. 84%, p < 0.001) at 2 years were significantly lower in the long stenting group than in the spot stenting group. The incidence of stent fracture, fracture type, and restenosis pattern did not differ between groups. Long stenting was an independent predictor of restenosis (hazard ratio [HR]: 2.0) along with other risk factors such as nonuse of clopidogrel (HR: 3.3) or cilostazol (HR: 2.2), small stent diameter (HR: 0.6), poor run-off (HR: 1.9), and post-procedural ankle-brachial index (HR: 0.1). Compared with spot stenting after adjustment using inverse probability of treatment weighting, long stenting, especially involving the P2 or P3 segment of the popliteal artery, was independently associated with 7.5-fold increases in restenosis risk (p < 0.001).ConclusionsThe primary patency was significantly higher with spot stenting than with long stenting following subintimal approach for long femoropopliteal chronic total occlusions. The risk of restenosis was especially higher when long stenting was extended to the distal popliteal artery.  相似文献   

14.
ObjectivesThis study sought to compare rates of stent thrombosis and major adverse cardiac and cerebrovascular events (MACCE) (composite of death, myocardial infarction, or stroke) after coronary stenting with drug-eluting stents (DES) versus bare-metal stents (BMS) in patients who participated in the DAPT (Dual Antiplatelet Therapy) study, an international multicenter randomized trial comparing 30 versus 12 months of dual antiplatelet therapy in subjects undergoing coronary stenting with either DES or BMS.BackgroundDespite antirestenotic efficacy of coronary DES compared with BMS, the relative risk of stent thrombosis and adverse cardiovascular events is unclear. Many clinicians perceive BMS to be associated with fewer adverse ischemic events and to require shorter-duration dual antiplatelet therapy than DES.MethodsProspective propensity-matched analysis of subjects enrolled into a randomized trial of dual antiplatelet therapy duration was performed. DES- and BMS-treated subjects were propensity-score matched in a many-to-one fashion. The study design was observational for all subjects 0 to 12 months following stenting. A subset of eligible subjects without major ischemic or bleeding events were randomized at 12 months to continued thienopyridine versus placebo; all subjects were followed through 33 months.ResultsAmong 10,026 propensity-matched subjects, DES-treated subjects (n = 8,308) had a lower rate of stent thrombosis through 33 months compared with BMS-treated subjects (n = 1,718, 1.7% vs. 2.6%; weighted risk difference −1.1%, p = 0.01) and a noninferior rate of MACCE (11.4% vs. 13.2%, respectively, weighted risk difference −1.8%, p = 0.053, noninferiority p < 0.001).ConclusionsDES-treated subjects have long-term rates of stent thrombosis that are lower than BMS-treated subjects. (The Dual Antiplatelet Therapy Study [DAPT study]; NCT00977938)  相似文献   

15.
ObjectivesThis study sought to assess the incidence and clinical impact of stent fracture (SF) after the PROMUS Element platinum-chromium everolimus-eluting stent (PtCr-EES).BackgroundSF remains an unresolved, clinically relevant issue, even in the newer-generation drug-eluting stent era.MethodsFrom March 2012 to August 2013, 816 patients with 1,094 lesions were treated only with PtCr-EES and 700 patients (85.7%) with 898 lesions undergoing follow-up angiography within 9 months after the index procedure were analyzed. SF was defined as complete or partial separation of the stent, as assessed by plain fluoroscopy, intravascular ultrasound, or optical coherence tomography during the follow-up. We assessed the rate of SF and the cumulative incidence of clinically driven target lesion revascularization and definite stent thrombosis within 9 months after the index procedure.ResultsSF was observed in 16 of 898 lesions (1.7%) and 16 of 700 patients (2.2%). Lesions with in-stent restenosis at baseline (odds ratio [OR]: 14.2, 95% confidence intervals [CI]: 5.09 to 39.7; p < 0.001) or hinge motion (OR: 4.31, 95% CI: 1.12 to 16.5; p = 0.03), and total stent length (per 10-mm increase; OR: 1.32, 95% CI: 1.12 to 1.57; p = 0.001) were predictors of SF. Cumulative incidence of clinically driven target lesion revascularization within 9-months was numerically higher in the SF group than that in the non-SF group (18.7% vs. 2.3%). Cumulative incidence of definite stent thrombosis within 9 months after the index procedure was similar between the SF and non-SF groups (0.0% vs. 0.23%).ConclusionsSF after PtCr-EES occurs in 1.7% of lesions and appears to be associated with clinically driven target lesion revascularization.  相似文献   

16.
ObjectivesThis study sought to investigate the long-term comparative efficacy and safety of paclitaxel-eluting balloon (PEB), paclitaxel-eluting stent (PES), or balloon angioplasty (BA) for the treatment of drug-eluting stent restenosis.BackgroundThe optimal treatment of drug-eluting stent restenosis remains unknown. Although PEB has shown encouraging results, the long-term clinical efficacy and safety of PEB remains poorly defined.MethodsA total of 402 patients with clinically significant restenosis in limus-eluting stents were randomly assigned to receive PEB (n = 137), PES (n = 131), or BA (n = 134). For this analysis, PEB versus PES and PEB versus BA were compared. The primary efficacy and safety endpoints were target lesion revascularization and the composite of death or myocardial infarction.ResultsAt a median follow-up of 3 years, the risk of target lesion revascularization was comparable with PEB versus PES (hazard ratio [HR]: 1.46, 95% confidence interval [CI]: 0.91 to 2.33; p = 0.11) and lower with PEB versus BA (HR: 0.51, 95% CI: 0.34 to 0.74; p < 0.001). The risk of death/myocardial infarction tended to be lower with PEB versus PES (HR: 0.55, 95% CI: 0.28 to 1.07; p = 0.08), due to a lower risk of death (HR: 0.38, 95% CI: 0.17 to 0.87; p = 0.02). The risk of death/myocardial infarction was similar with PEB versus BA (HR: 0.96, 95% CI: 0.46 to 2.0; p = 0.91).ConclusionsAt 3 years, the use of PEB as compared with PES to treat patients with limus-eluting stent restenosis has similar efficacy and safety. PEB remains superior to BA. The sustained efficacy without trade-off in safety supports the role of PEB as treatment option for patients with drug-eluting stent restenosis. (Intracoronary Stenting and Angiographic Results: Drug Eluting Stent In-Stent Restenosis: 3 Treatment Approaches [ISAR-DESIRE 3]; NCT00987324)  相似文献   

17.
ObjectivesThe aim of this study was to assess outcomes after percutaneous coronary intervention (PCI) with stents in patients treated with thoracic external beam radiation therapy (EBRT).BackgroundThoracic EBRT for cancer is associated with long-term cardiotoxic sequelae. The impact of EBRT on patients requiring coronary stents is unclear.MethodsWe analyzed outcomes after PCI in cancer survivors treated with curative thoracic EBRT before and after stenting between 1998 and 2012. Reference groups were propensity-matched cohorts with stenting but no EBRT. Primary endpoint was target lesion revascularization (TLR), a clinical surrogate for restenosis. Secondary endpoints included myocardial infarction (MI) and cardiac and overall mortality.ResultsWe identified 115 patients treated with EBRT a median 3.6 years after stenting (group A) and 45 patients treated with EBRT a median 2.2 years before stenting (group B). Long-term mean TLR rates in group A (3.2 vs. 6.6%; hazard ratio: 0.6; 95% confidence interval: 0.2 to 1.6; p = 0.31) and group B (9.2 vs. 9.7%; hazard ratio: 1.2; 95% confidence interval: 0.4 to 3.4; p = 0.79) were similar to rates in corresponding control patients (group A: 1,390 control patients; group B: 439 control patients). Three years post-PCI, group A had higher overall mortality (48.6% vs. 13.9%; p < 0.001) but not MI (4.8% vs. 4.3%; p = 0.93) or cardiac mortality (2.3% vs. 3.6%; p = 0.66) rates versus control patients. There were no significant differences in MI, cardiac, or overall mortality rates in group B.ConclusionsThoracic EBRT is not associated with increased stent failure rates when used before or after PCI. A history of PCI should not preclude the use of curative thoracic EBRT in cancer patients or vice versa. Optimal treatment of cancer should be the goal.  相似文献   

18.
ObjectivesThis study sought to investigate the clinical outcomes based on the assessment of quantitative coronary angiography–maximal lumen diameter (Dmax).BackgroundAssessment of pre-procedural Dmax of proximal and distal sites has been used for Absorb scaffold size selection in the ABSORB studies.MethodsA total of 1,248 patients received Absorb scaffolds in the ABSORB Cohort B (ABSORB Clinical Investigation, Cohort B) study (N = 101), ABSORB EXTEND (ABSORB EXTEND Clinical Investigation) study (N = 812), and ABSORB II (ABSORB II Randomized Controlled Trial) trial (N = 335). The incidence of major adverse cardiac events (MACE) (a composite of cardiac death, any myocardial infarction [MI], and ischemia-driven target lesion revascularization) was analyzed according to the Dmax subclassification of scaffold oversize group versus scaffold nonoversize group.ResultsOf 1,248 patients, pre-procedural Dmax was assessed in 1,232 patients (98.7%). In 649 (52.7%) patients, both proximal and distal Dmax values were smaller than the nominal size of the implanted scaffold (scaffold oversize group), whereas in 583 (47.3%) of patients, the proximal and/or distal Dmax were larger than the implanted scaffold (scaffold nonoversize group). The rates of MACE and MI at 1 year were significantly higher in the scaffold oversize group than in the scaffold nonoversize group (MACE 6.6% vs. 3.3%; log-rank p < 0.01, all MI: 4.6% vs. 2.4%; log-rank p = 0.04), mainly driven by a higher MI rate within 1 month post-procedure (3.5% vs. 1.9%; p = 0.08). The independent MACE determinants were both Dmax smaller than the scaffold nominal size (odds ratio [OR]: 2.13, 95% confidence interval [CI]: 1.22 to 3.70; p < 0.01) and the implantation of overlapping scaffolds (OR: 2.10, 95% CI: 1.17 to 3.80; p = 0.01).ConclusionsImplantation of an oversized Absorb scaffold in a relatively small vessel appears to be associated with a higher 1-year MACE rate driven by more frequent early MI. (ABSORB Clinical Investigation, Cohort B [ABSORB Cohort B], NCT00856856; ABSORB EXTEND Clinical Investigation [ABSORB EXTEND], NCT01023789; ABSORB II Randomized Controlled Trial [ABSORB II], NCT01425281)  相似文献   

19.
ObjectivesThis study sought to evaluate the incidence of plaque rupture (PR), plaque erosion (PE), and calcified nodule (CN) using optical coherence tomography (OCT) in patients with ST-segment elevation myocardial infarction (STEMI); to compare detailed morphologic plaque characteristics of PR, PE, and CN with optical coherence tomography and intravascular ultrasound; and to compare the post-procedure outcomes among PR, PE, and CN.BackgroundThe incidence and detailed morphologic characteristics of PR, PE, and CN in STEMI patients and their outcome after percutaneous coronary intervention (PCI) are unknown.MethodsA total of 112 STEMI patients who underwent PCI within 12 h from symptom onset were included. Both optical coherence tomography and intravascular ultrasound were performed following aspiration thrombectomy.ResultsThe incidence of PR, PE, and CN was 64.3%, 26.8%, and 8.0%, respectively. PE and CN, compared with PR, had more fibrous plaque (p < 0.001 and p < 0.001) and less thin-cap fibroatheroma (p < 0.001 and p < 0.001) as well as smaller plaque burden (p = 0.003 and p = 0.001) and remodeling index (p = 0.003 and p < 0.001). PE had greater plaque eccentricity index than PR and CN (p < 0.001 and p < 0.001). CN had greater calcified arc and shallower calcium than PR (p < 0.001 and p < 0.001) or PE (p < 0.001 and p < 0.001). More than one-half of CN had negative remodeling. PE had a lower incidence of no-reflow phenomenon after PCI than PR (p = 0.011).ConclusionsPE was the underlying mechanism in one-fourth of STEMI. PE was characterized by eccentric fibrous plaque. CN was characterized by superficial large calcium and negative remodeling. PE was associated with less microvascular damage after PCI.  相似文献   

20.
ObjectivesThis study investigated the impact of final kissing ballooning (FKB) after main vessel (MV) stenting on outcomes in patients with coronary bifurcation lesions after application of the 1-stent technique.BackgroundAlthough FKB has been established as the standard method for bifurcation lesions treated with a 2-stent strategy, its efficacy in a 1-stent approach is highly controversial.MethodsThis study enrolled 1,901 patients with a bifurcation lesion with a side branch diameter ≥2.3 mm, treated solely with the 1-stent technique using a drug-eluting stent from 18 centers in Korea between January 1, 2003 and December 31, 2009. The primary outcome was major adverse cardiac events (MACE)—cardiac death, myocardial infarction, or target lesion revascularization. Propensity score-matching analysis was also performed.ResultsFKB was performed in 620 patients and the post minimal lumen diameter of the MV and side branch was larger in the FKB group than in the non-FKB group. During follow-up (median 36 months), the incidence of MACE (adjusted hazard ratio [HR]: 0.68, 95% confidence interval [CI]: 0.46 to 0.99; p = 0.048) was lower in the FKB group than the non-FKB group. After propensity score matching (545 pairs), the FKB group had a lower incidence of MACE (adjusted HR: 0.50, 95% CI: 0.30 to 0.85; p = 0.01), and target lesion revascularization in the MV (adjusted HR: 0.51, 95% CI: 0.28 to 0.93; p = 0.03) and both vessels (adjusted HR: 0.47, 95% CI: 0.25 to 0.90; p = 0.02) than in the non-FKB group.ConclusionsIn coronary bifurcation lesions, we demonstrated that the 1-stent technique with FKB was associated with a favorable long-term clinical outcome, mainly driven by the reduction of target lesion revascularization in the MV or both vessels as a result of an increase in minimal lumen diameter. (Korean Coronary Bifurcation Stenting Registry II [COBIS II]: NCT01642992)  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号