首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
ObjectivesThe purpose of this study was to compare the 2-year safety and effectiveness of new- versus early-generation drug-eluting stents (DES) according to the severity of coronary artery disease (CAD) as assessed by the SYNTAX (Synergy between Percutaneous Coronary Intervention with Taxus and Cardiac Surgery) score.BackgroundNew-generation DES are considered the standard-of-care in patients with CAD undergoing percutaneous coronary intervention. However, there are few data investigating the effects of new- over early-generation DES according to the anatomic complexity of CAD.MethodsPatient-level data from 4 contemporary, all-comers trials were pooled. The primary device-oriented clinical endpoint was the composite of cardiac death, myocardial infarction, or ischemia-driven target-lesion revascularization (TLR). The principal effectiveness and safety endpoints were TLR and definite stent thrombosis (ST), respectively. Adjusted hazard ratios (HRs) with 95% confidence intervals (CIs) were calculated at 2 years for overall comparisons, as well as stratified for patients with lower (SYNTAX score ≤11) and higher complexity (SYNTAX score >11).ResultsA total of 6,081 patients were included in the study. New-generation DES (n = 4,554) compared with early-generation DES (n = 1,527) reduced the primary endpoint (HR: 0.75 [95% CI: 0.63 to 0.89]; p = 0.001) without interaction (p = 0.219) between patients with lower (HR: 0.86 [95% CI: 0.64 to 1.16]; p = 0.322) versus higher CAD complexity (HR: 0.68 [95% CI: 0.54 to 0.85]; p = 0.001). In patients with SYNTAX score >11, new-generation DES significantly reduced TLR (HR: 0.36 [95% CI: 0.26 to 0.51]; p < 0.001) and definite ST (HR: 0.28 [95% CI: 0.15 to 0.55]; p < 0.001) to a greater extent than in the low-complexity group (TLR pint = 0.059; ST pint = 0.013). New-generation DES decreased the risk of cardiac mortality in patients with SYNTAX score >11 (HR: 0.45 [95% CI: 0.27 to 0.76]; p = 0.003) but not in patients with SYNTAX score ≤11 (pint = 0.042).ConclusionsNew-generation DES improve clinical outcomes compared with early-generation DES, with a greater safety and effectiveness in patients with SYNTAX score >11.  相似文献   

2.
ObjectivesThis study sought to investigate the long-term comparative efficacy and safety of paclitaxel-eluting balloon (PEB), paclitaxel-eluting stent (PES), or balloon angioplasty (BA) for the treatment of drug-eluting stent restenosis.BackgroundThe optimal treatment of drug-eluting stent restenosis remains unknown. Although PEB has shown encouraging results, the long-term clinical efficacy and safety of PEB remains poorly defined.MethodsA total of 402 patients with clinically significant restenosis in limus-eluting stents were randomly assigned to receive PEB (n = 137), PES (n = 131), or BA (n = 134). For this analysis, PEB versus PES and PEB versus BA were compared. The primary efficacy and safety endpoints were target lesion revascularization and the composite of death or myocardial infarction.ResultsAt a median follow-up of 3 years, the risk of target lesion revascularization was comparable with PEB versus PES (hazard ratio [HR]: 1.46, 95% confidence interval [CI]: 0.91 to 2.33; p = 0.11) and lower with PEB versus BA (HR: 0.51, 95% CI: 0.34 to 0.74; p < 0.001). The risk of death/myocardial infarction tended to be lower with PEB versus PES (HR: 0.55, 95% CI: 0.28 to 1.07; p = 0.08), due to a lower risk of death (HR: 0.38, 95% CI: 0.17 to 0.87; p = 0.02). The risk of death/myocardial infarction was similar with PEB versus BA (HR: 0.96, 95% CI: 0.46 to 2.0; p = 0.91).ConclusionsAt 3 years, the use of PEB as compared with PES to treat patients with limus-eluting stent restenosis has similar efficacy and safety. PEB remains superior to BA. The sustained efficacy without trade-off in safety supports the role of PEB as treatment option for patients with drug-eluting stent restenosis. (Intracoronary Stenting and Angiographic Results: Drug Eluting Stent In-Stent Restenosis: 3 Treatment Approaches [ISAR-DESIRE 3]; NCT00987324)  相似文献   

3.
ObjectivesThe aim of the current study was to compare everolimus-eluting stents (EES) with sirolimus-eluting stents (SES) in patients undergoing primary angioplasty.BackgroundDrug-eluting stents may offer benefits in terms of repeat revascularization. However, as shown for first-generation drug-eluting stents, they may be counterbalanced by a potential higher risk of stent thrombosis, especially among patients with ST-segment elevation myocardial infarction (STEMI). No data have been reported so far on the long-term benefits and safety of the new generation of drug-eluting stents in STEMI.MethodsConsecutive STEMI patients admitted within 12 h of symptom onset and undergoing primary angioplasty and stent implantation at a tertiary center with 24-h primary percutaneous coronary intervention capability were randomly assigned to SES or EES. The primary endpoint was a major adverse cardiac event at 3-year follow-up. The secondary endpoints were death, reinfarction, definite or probable stent thrombosis, and target vessel revascularization at 3-year follow-up. No patient was lost to follow-up.ResultsFrom April 2007 to May 2009, 500 patients with STEMI were randomized to EES (n = 250) or SES (n = 250). No difference was observed in terms of baseline demographic and clinical characteristics between the groups. No difference was observed between the groups in terms of number of implanted stents per patient or total stent length. However, a larger reference diameter was observed with SES (3.35 ± 0.51 mm vs. 3.25 ± 0.51 mm, p = 0.001), whereas patients randomized to EES more often received glycoprotein IIb/IIIa inhibitors (54.4% vs. 42.4%, p = 0.006). Follow-up data were available in all patients (1,095 ± 159 days). No significant difference was observed between EES and SES in major adverse cardiac events (16% vs. 20.8%, adjusted hazard ratio [HR]: 0.75 [95% confidence interval (CI): 0.5 to 1.13], p = 0.17), cardiac death (4.4% vs. 5.6%, adjusted HR: 0.77 [95% CI: 0.35 to 1.71], p = 0.53), recurrent MI (6.4% vs. 10%, adjusted HR: 0.62 [95% CI: 0.33 to 1.16], p = 0.13), and target vessel revascularization (4.8% vs. 4.8%, adjusted HR: 1.00 [95% CI: 0.45 to 2.32], p = 0.99). However, EES was associated with a significant reduction in stent thrombosis (1.6% vs. 5.2%, adjusted HR: 0.3 [95% CI: 0.1 to 0.92], p = 0.035).ConclusionsThis study shows that among STEMI patients undergoing primary angioplasty, EES has similar efficacy as SES, but is associated with a significant reduction in stent thrombosis. (Randomized Comparison of Everolimus Eluting Stents and Sirolimus Eluting Stent in Patients With ST Elevation Myocardial Infarction [RACES-MI]; NCT01684982)  相似文献   

4.
ObjectivesThis study sought to assess the incidence and clinical impact of stent fracture (SF) after the PROMUS Element platinum-chromium everolimus-eluting stent (PtCr-EES).BackgroundSF remains an unresolved, clinically relevant issue, even in the newer-generation drug-eluting stent era.MethodsFrom March 2012 to August 2013, 816 patients with 1,094 lesions were treated only with PtCr-EES and 700 patients (85.7%) with 898 lesions undergoing follow-up angiography within 9 months after the index procedure were analyzed. SF was defined as complete or partial separation of the stent, as assessed by plain fluoroscopy, intravascular ultrasound, or optical coherence tomography during the follow-up. We assessed the rate of SF and the cumulative incidence of clinically driven target lesion revascularization and definite stent thrombosis within 9 months after the index procedure.ResultsSF was observed in 16 of 898 lesions (1.7%) and 16 of 700 patients (2.2%). Lesions with in-stent restenosis at baseline (odds ratio [OR]: 14.2, 95% confidence intervals [CI]: 5.09 to 39.7; p < 0.001) or hinge motion (OR: 4.31, 95% CI: 1.12 to 16.5; p = 0.03), and total stent length (per 10-mm increase; OR: 1.32, 95% CI: 1.12 to 1.57; p = 0.001) were predictors of SF. Cumulative incidence of clinically driven target lesion revascularization within 9-months was numerically higher in the SF group than that in the non-SF group (18.7% vs. 2.3%). Cumulative incidence of definite stent thrombosis within 9 months after the index procedure was similar between the SF and non-SF groups (0.0% vs. 0.23%).ConclusionsSF after PtCr-EES occurs in 1.7% of lesions and appears to be associated with clinically driven target lesion revascularization.  相似文献   

5.
ObjectivesThis study aimed to investigate the clinical outcomes of patients presenting with recurrent drug-eluting stent (DES) in-stent restenosis (ISR) treated with a second-generation DES or with a drug-coated balloon (DCB).BackgroundTo date, there are no reports of DCB treatment and limited data with regard to the efficacy of further DES implantation for recurrent ISR.MethodsBetween January 2008 and December 2013, 171 lesions were assessed for eligibility (82 lesions in the second-generation DES group and 89 lesions in the DCB group).ResultsAcute gain was greater in the second-generation DES group (second-generation DES, 2.09 ± 0.53 mm vs. DCBs, 1.60 ± 0.62 mm, p < 0.001). The rates of major adverse cardiac events were comparable (at 1 year, DES 14.0% vs. DCBs 12.3%; at 2 years, DES 28.8% vs. DCBs 43.5%, p = 0.21). Major adverse cardiac event rates were mainly driven by target lesion revascularization (at 1 year, DES 12.5% vs. DCBs 10.9%; at 2 years, DES 27.7% vs. DCBs 38.3%; p = 0.40). Definite scaffold thrombosis occurred in 2 patients (1 patient in each group). Multivariable analysis revealed ISR recurrence within 1 year (hazard ratio: 2.43, 95% confidence interval: 1.14 to 5.18, p = 0.02) and lesion length (per 10-mm increase) (hazard ratio: 1.15, 95% confidence interval: 1.00 to 1.32, p = 0.049) to be independent predictors of TLR.ConclusionsThe results after both treatments were equivalent. ISR recurrence within 1 year of the first reintervention and lesion length were independent predictors of future target lesion revascularization. Larger studies are required to confirm the late (>1 year) differences with regard to clinical outcomes.  相似文献   

6.
ObjectivesThis study sought to assess the frequency and clinical impact of dual antiplatelet therapy (DAPT) nonadherence.BackgroundThere are limited data on the impact of DAPT nonadherence during the first year after a second-generation drug-eluting stent placement.MethodsAfter successful Endeavor zotarolimus-eluting stent implantation, 2,265 patients were enrolled in a registry with limited exclusions and monitored during 12 months of prescribed DAPT. Predictors of any nonadherence (ANA) at 6 months were analyzed by multivariable analysis, and the association between ANA at 6 or 12 months with the endpoints of death, myocardial infarction, and stent thrombosis was assessed.ResultsThe study population included 30% female patients, 34% with diabetes and 36% with acute coronary syndromes. ANA occurred in 208 patients (9.6%) before 6 months and 378 patients (18.5%) before 1 year. Major bleeding (odds ratio [OR]: 12.83, 95% confidence interval [CI]: 7.55 to 21.80, p < 0.001) was the only predictor of ANA at 6 months. In time-dependent analyses, ANA before 6 months was associated with an increased risk of death or myocardial infarction (7.6% vs. 3.0%, p < 0.001) and a numerical increase in stent thrombosis (2.0% vs. 0.9%, p = 0.12). After adjustment for baseline differences, ANA within 6 months remained associated with death or MI (OR: 1.95, 95% CI: 1.02 to 3.75). ANA occurring after 6 months did not increase the risk of subsequent ischemic events.ConclusionsDAPT ANA occurs frequently and is associated with increased risk for thrombotic complications if it occurs within the first 6 months. Major bleeding was a significant correlate of DAPT ANA within 6 months. (EDUCATE: The MEDTRONIC Endeavor Drug Eluting Stenting: Understanding Care, Antiplatelet Agents and Thrombotic Events; NCT01069003)  相似文献   

7.
ObjectivesThis study aimed to investigate the characteristics of neoatherosclerosis (NA) in patients with diabetes mellitus (DM) after drug-eluting stent (DES) implantation using optical coherence tomography.BackgroundNA is an important substrate for stent failure. In vivo NA characteristics in DM patients have not been investigated.MethodsA total of 397 patients with 452 DES who underwent follow-up optical coherence tomography examination after DES implantation were enrolled. Characteristics of NA were compared between DM and non-DM patients. Neovascularization was defined as signal-poor holes or tubular structures with a diameter of 50 to 300 μm.ResultsA total of 123 DES with NA lesions in 115 patients were identified. The incidence of NA was similar between DM and non-DM patients (29.6% vs. 28.6%; p = 0.825). Compared with the non-DM group, neovascularization was more frequently observed in the DM group (55.1% vs. 32.4%; p = 0.012). The multivariate logistic model demonstrated that DM (odds ratio: 3.00; 95% confidence interval: 1.31 to 6.81; p = 0.009) and follow-up duration (odds ratio: 1.03; 95% confidence interval: 1.02 to 1.05; p < 0.001) were the independent predictors for neovascularization in NA lesions. DM patients with glycated hemoglobin ≥7.0% had a higher prevalence of thin-cap fibroatheroma compared with those with glycated hemoglobin <7.0% (40.0% vs. 8.3%; p = 0.01).ConclusionsThe incidence of NA was similar between patients with and without DM. Neovascularization in NA lesions was more frequent in those with DM. Poorly controlled DM patients had a higher incidence of thin-cap fibroatheroma, compared with those with well-controlled DM.  相似文献   

8.
ObjectivesThis study sought to compare rates of stent thrombosis and major adverse cardiac and cerebrovascular events (MACCE) (composite of death, myocardial infarction, or stroke) after coronary stenting with drug-eluting stents (DES) versus bare-metal stents (BMS) in patients who participated in the DAPT (Dual Antiplatelet Therapy) study, an international multicenter randomized trial comparing 30 versus 12 months of dual antiplatelet therapy in subjects undergoing coronary stenting with either DES or BMS.BackgroundDespite antirestenotic efficacy of coronary DES compared with BMS, the relative risk of stent thrombosis and adverse cardiovascular events is unclear. Many clinicians perceive BMS to be associated with fewer adverse ischemic events and to require shorter-duration dual antiplatelet therapy than DES.MethodsProspective propensity-matched analysis of subjects enrolled into a randomized trial of dual antiplatelet therapy duration was performed. DES- and BMS-treated subjects were propensity-score matched in a many-to-one fashion. The study design was observational for all subjects 0 to 12 months following stenting. A subset of eligible subjects without major ischemic or bleeding events were randomized at 12 months to continued thienopyridine versus placebo; all subjects were followed through 33 months.ResultsAmong 10,026 propensity-matched subjects, DES-treated subjects (n = 8,308) had a lower rate of stent thrombosis through 33 months compared with BMS-treated subjects (n = 1,718, 1.7% vs. 2.6%; weighted risk difference −1.1%, p = 0.01) and a noninferior rate of MACCE (11.4% vs. 13.2%, respectively, weighted risk difference −1.8%, p = 0.053, noninferiority p < 0.001).ConclusionsDES-treated subjects have long-term rates of stent thrombosis that are lower than BMS-treated subjects. (The Dual Antiplatelet Therapy Study [DAPT study]; NCT00977938)  相似文献   

9.
ObjectivesThis study sought to evaluate in-hospital outcomes and 3-year mortality of patients presenting with unprotected left main stem occlusion (ULMSO) treated with primary percutaneous coronary intervention (PPCI).BackgroundLimited data exists about management and outcome following presentation with ULMSO.MethodsFrom January 1, 2007 to December 21, 2012, 446,257 PCI cases were recorded in the British Cardiovascular Intervention Society database of all PCI cases in England and Wales. Of those, 568 were patients having emergency PCI for ST-segment elevation infarction (0.6% of all PPCI) who presented with ULMSO (TIMI [Thrombolysis In Myocardial Infarction] flow grade 0/1 and stenosis >75%), and they were compared with 1,045 emergency patients treated with nonocclusive LMS disease. Follow-up was obtained through linkage with the Office of National Statistics.ResultsPresentation with ULMSO, compared with nonocclusive LMS disease, was associated with a doubling in the likelihood of periprocedural shock (57.9% vs. 27.9%; p < 0.001) and/or intra-aortic balloon pump support (52.5% vs. 27.2%; p < 0.001). In-hospital (43.3% vs. 20.6%; p < 0.001), 1-year (52.8% vs. 32.4%; p < 0.001), and 3-year mortality (73.9% vs 52.3%, p < 0.001) rates were higher in patients with ULMSO, compared with patients presenting with a patent LMS, and were significantly influenced by the presence of cardiogenic shock. ULMSO and cardiogenic shock were independent predictors of 30-day (hazard ratio [HR]: 1.61 [95% confidence interval (CI): 1.07 to 2.41], p = 0.02, and HR: 5.43 [95% CI: 3.23 to 9.12], p<0.001, respectively) and 3-year all-cause mortality (HR: 1.52 [95% CI: 1.06 to 2.17], p = 0.02, and HR: 2.98 [95% CI: 1.99 to 4.49], p < 0.001, respectively).ConclusionsIn patients undergoing PPCI for ULMSO, acute outcomes are poor and additional therapies are required to improve outcome. However, long-term outcomes for survivors of ULMSO are encouraging.  相似文献   

10.
ObjectivesThe purpose of this study was to investigate the differential clinical outcomes after percutaneous coronary intervention (PCI) for coronary bifurcation lesions with 1- or 2-stenting techniques using first- or second-generation drug-eluting stents (DES).BackgroundThe 2-stenting technique has been regarded to have worse clinical outcomes than the 1-stenting technique after bifurcation PCI with first-generation DES. However, there has been a paucity of data comparing the 1- and 2-stenting techniques with the use of second-generation DES.MethodsPatient-level pooled analysis was performed with 3,162 patients undergoing PCI using first- or second-generation DES for bifurcation lesions from the “Korean Bifurcation Pooled Cohorts” (COBIS [Coronary Bifurcation Stenting] II, EXCELLENT [Registry to Evaluate Efficacy of Xience/Promus Versus Cypher in Reducing Late Loss After Stenting], and RESOLUTE-Korea [Registry to Evaluate the Efficacy of Zotarolimus-Eluting Stent]). The 3-year clinical outcomes were compared between 1- and 2-stenting techniques, stratified by the type of DES.ResultsWith first-generation DES, rates of target lesion failure (TLF) or patient-oriented composite outcome (POCO) (a composite of all death, any myocardial infarction, any repeat revascularization, and cerebrovascular accidents) at 3 years were significantly higher after the 2-stenting than the 1-stenting technique (TLF 8.6% vs. 17.5%; p < 0.001; POCO 18.1% vs. 28.5%, p < 0.001). With second-generation DES, however, there was no difference between 1- and 2-stenting techniques (TLF 5.4% vs. 5.8%; p = 0.768; POCO 11.2% vs. 12.9%; p = 0.995). The differential effects of 2-stenting technique on the prognosis according to the type of DES were also corroborated with similar results by the inverse probability weighted model. The 2-stenting technique was a significant independent predictor of TLF in first-generation DES (hazard ratio: 2.046; 95% confidence interval: 1.114 to 3.759; p < 0.001), but not in second-generation DES (hazard ratio: 0.667; 95% confidence interval: 0.247 to 1.802; p = 0.425).ConclusionsPatient-level pooled analysis of 3,162 patients in Korean Bifurcation Pooled Cohorts demonstrated that the 2-stenting technique showed comparable outcomes to 1-stenting technique with second-generation DES, which is different from the results of first-generation DES favoring the 1-stenting technique.  相似文献   

11.
ObjectivesThis study examined whether coronary angioscopy-verified in-stent yellow plaque at 1 year after drug-eluting stent (DES) implantation is associated with future event of very late stent failure (VLSF).BackgroundAtherosclerosis detected as yellow plaque by angioscopy has been associated with future events of acute coronary syndrome. Development of in-stent neoatherosclerosis is a probable mechanism of VLSF.MethodsThis study included 360 consecutive patients who received successful angioscopic examination at 1 year after implantation of a DES. They were clinically followed up for VLSF defined as cardiac death, acute myocardial infarction or unstable angina, or need for revascularization associated with the stent site.ResultsThe follow-up interval was 1,558 ± 890 days (4.3 ± 2.4 years). The incidence of VLSF was significantly higher in the patients with yellow plaque than in those without (8.1% vs. 1.6%; log rank p = 0.02). Multivariable analysis revealed the presence of yellow plaque (hazard ratio [HR]: 5.38; p = 0.02) and absence of statin therapy (HR: 3.25; p = 0.02) as risks of VLSF.ConclusionsIn-stent atherosclerosis evaluated by yellow plaque at 1 year after the implantation of DES and the absence of statin therapy were risks of VLSF. The underlying mechanism of VLSF appeared to be the progression of atherosclerosis as demonstrated by the yellow plaque.  相似文献   

12.
ObjectivesThis study sought to evaluate the intravascular ultrasound (IVUS) minimal lumen area (MLA) for functionally significant left main coronary artery (LMCA) stenosis using fractional flow reserve (FFR) as the standard.BackgroundThe evaluation of significant LMCA stenosis remains challenging.MethodsWe identified 112 patients with isolated ostial and shaft intermediate LMCA stenosis (angiographic diameter stenosis of 30% to 80%) who underwent IVUS and FFR measurement.ResultsThe FFR was ≤0.80 in 66 LMCA lesions (59%); these exhibited smaller reference vessels, smaller minimal lumen diameter, greater diameter of stenosis, longer lesion length, smaller MLA, larger plaque burden, and more frequent plaque rupture. The independent factors of an FFR of ≤0.80 were plaque rupture (odds ratio [OR]: 4.47; 95% Confidence Interval (CI): 1.35 to 14.8; p = 0.014); body mass index (OR: 1.19; 95% CI: 1.00 to 1.41; p = 0.05), age (OR: 0.95; 95% CI: 0.90 to 1.00; p = 0.031), and IVUS MLA (OR: 0.37; 95% CI: 0.25 to 0.56; p < 0.001). The optimal IVUS MLA cutoff value for an FFR of ≤0.80 was 4.5 mm2 (77% sensitivity, 82% specificity, 84% positive predictive value, 75% negative predictive value, area under the curve: 0.83, 95% CI: 0.76 to 0.96; p < 0.001) overall and 4.1 to 4.5 mm2 in various subgroups. Adjustment for the body surface area, body mass index, and left ventricular mass did not improve the diagnostic accuracy of the IVUS MLA.ConclusionsIn patients with isolated ostial and shaft intermediate LMCA stenosis, an IVUS-derived MLA of ≤4.5 mm2 is a useful index of an FFR of ≤0.80.  相似文献   

13.
ObjectivesThis study sought to examine whether imaging of the atrioventricular (AV) membranous septum (MS) by computed tomography (CT) can be used to identify patient-specific anatomic risk of high-degree AV block and permanent pacemaker (PPM) implantation before transcatheter aortic valve implantation (TAVI) with self-expandable valves.BackgroundMS length represents an anatomic surrogate of the distance between the aortic annulus and the bundle of His and may therefore be inversely related to the risk of conduction system abnormalities after TAVI.MethodsSeventy-three consecutive patients with severe aortic stenosis underwent contrast-enhanced CT before TAVI. The aortic annulus, aortic valve, and AV junction were assessed, and MS length was measured in the coronal view.ResultsIn 13 patients (18%), high-degree AV block developed, and 21 patients (29%) received a PPM. Multivariable logistic regression analysis revealed MS length as the most powerful pre-procedural independent predictor of high-degree AV block (odds ratio [OR]: 1.35, 95% confidence interval [CI]: 1.1 to 1.7, p = 0.01) and PPM implantation (OR: 1.43, 95% CI: 1.1 to 1.8, p = 0.002). When taking into account pre- and post-procedural parameters, the difference between MS length and implantation depth emerged as the most powerful independent predictor of high-degree AV block (OR: 1.4, 95% CI: 1.2 to 1.7, p < 0.001), whereas the difference between MS length and implantation depth and calcification in the basal septum were the most powerful independent predictors of PPM implantation (OR: 1.39, 95% CI: 1.2 to 1.7, p < 0.001 and OR: 4.9, 95% CI: 1.2 to 20.5, p = 0.03; respectively).ConclusionsShort MS, insufficient difference between MS length and implantation depth, and the presence of calcification in the basal septum, factors that may all facilitate mechanical compression of the conduction tissue by the implanted valve, predict conduction abnormalities after TAVI with self-expandable valves. CT assessment of membranous septal anatomy provides unique pre-procedural information about the patient-specific propensity for the risk of AV block.  相似文献   

14.
ObjectivesThis study sought to evaluate the safety and efficacy of stent retriever for the management of acute ischemic stroke.BackgroundStroke is the third leading cause of death and the most common cause of disability in the United States. Early reperfusion has been associated with favorable outcomes. Stent retrievers are novel endovascular devices that provide vessel recanalization via thrombus retrieval mechanical thrombectomy.MethodsThe authors performed a literature search using PubMed, EMBASE, and Cochrane Central Register of Controlled Trials from May 2005 to May 2015. Randomized controlled trails (RCTs) comparing endovascular therapy (ET) with the use of retrievable stents against standard therapy (ST) for the management of acute stroke were included.ResultsFive RCTs (the MR CLEAN, ESCAPE, EXTEND-IA, SWIFT-PRIME, and REVASCAT studies) with 634 patients in the ET group and 653 patients in the ST group met inclusion criteria. The frequency of a low 90-day modified Rankin Score (0 to 2) in the intervention group was 42.6% compared with 26.1% in the control group (odds ratio: 2.43; 95% confidence interval [CI]: 1.9 to 3.09; p < 0.0001). The frequency of intracranial bleeding was 4.2% in the ET group compared with 4.3% in the ST group (risk ratio: 1.08; 95% CI: 0.64 to 1.82; p = 0.78). 90-day mortality was 15.1% in the ET group compared with 18.7% in the ST group (risk ratio: 0.81; 95% CI: 0.58 to 1.12; p = 0.19). There was no evidence of significant heterogeneity or publication bias for any of the endpoints.ConclusionsOn the basis of the results of this meta-analysis of RCTs, ET with stent retrievers appears as a safe and effective therapeutic option for acute ischemic stroke due to large vessel occlusion.  相似文献   

15.
ObjectivesThe aim of this study was to investigate the correlation between in-stent neointimal tissue without features of neoatherosclerosis and long-term clinical outcomes.BackgroundRecent studies have reported differential morphological characteristics of in-stent neointimal tissue assessed by optical coherence tomography (OCT).MethodsThe study population consisted of 336 patients with 368 drug-eluting stent-treated lesions. Patients received a follow-up OCT examination without any intervention. OCT-based neointima was categorized as homogeneous (n = 227 lesions in 208 patients), heterogeneous (n = 79 lesions in 73 patients), or layered (n = 62 lesions in 55 patients). Major adverse cardiac events (MACE) (a composite of cardiac death, nonfatal myocardial infarction, or target lesion revascularization) were assessed according to neointimal patterns during long-term clinical follow-up after OCT examination.ResultsThe time interval between stent implantation and OCT examination was similar among the 3 groups (p = 0.64). On multivariate logistic regression analysis, the significant determinant for the heterogeneous neointima was age (odds ratio [OR]: 1.037, 95% confidence interval [CI]: 1.007 to 1.068, p = 0.015) and an initial clinical presentation of acute coronary syndrome (OR: 1.967, 95% CI: 1.159 to 3.339, p = 0.012). The overall median follow-up duration for all patients after follow-up OCT examination was 31.0 months, and this was statistically different among the heterogeneous group (22.0 months), the homogeneous group (34.0 months), and the layered group (28.0 months, overall p = 0.002). MACE occurred more frequently in patients with heterogeneous neointima over a median 31-month follow-up period after OCT examination (13.7% vs. 2.9% in homogeneous vs. 7.3% in layered, p = 0.001). A propensity score–adjusted Cox regression analysis showed that independent risk factors for MACE were inclusion in the heterogeneous neointima (hazard ratio: 3.925, 95% CI: 1.445 to 10.662, p = 0.007) and minimal lumen cross-sectional area (hazard ratio: 0.368, 95% CI: 0.242 to 0.560, p < 0.001).ConclusionsDetermination of neointimal characteristics is helpful in predicting long-term clinical outcomes. Our data suggest that heterogeneous lesions are linked to poor long-term clinical prognoses.  相似文献   

16.
ObjectivesThe aim of this study was to investigate the hypothesis that a novel biodegradable polymer–coated, cobalt-chromium (CoCr), sirolimus-eluting stent (BP-SES) is noninferior in safety and efficacy outcomes compared with a durable polymer (DP)-SES.BackgroundNo randomized trials have the compared safety and efficacy of BP-SES versus DP-SES on similar CoCr platforms, thereby isolating the effect of the polymer type.MethodsIn this prospective, single-blind, randomized trial conducted at 32 Chinese sites, 2,737 patients eligible for coronary stenting were treated with BP- or DP-SES in a 2:1 ratio. The primary endpoint was 12-month target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction, or clinically indicated target lesion revascularization. Secondary endpoints included TLF components, and definite/probable stent thrombosis.ResultsAt 12 months, the difference in the primary endpoint of TLF between BP-SES (6.3%) and DP-SES (6.1%) groups was 0.25% (95% confidence interval: −1.67% to 2.17%, p for noninferiority = 0.0002), demonstrating noninferiority of BP-SES to DP-SES. Individual TLF components of cardiac death (0.7% vs. 0.6%, p = 0.62), target vessel myocardial infarction (3.6% vs. 4.3%, p = 0.39), and clinically indicated target lesion revascularization (2.6% vs. 2.2%, p = 0.50) were similar, as were low definite/probable stent thrombosis rates (0.4% vs. 0.6%, p = 0.55).ConclusionsIn this large-scale real-world trial, BP-SES was noninferior to DP-SES for 1-year TLF. (Evaluate Safety and Effectiveness of the Tivoli ® DES and the Firebird ® DES for Treatment of Coronary Revascularization; NCT01681381)  相似文献   

17.
ObjectivesThis study sought to determine mortality rates among cardiogenic shock (CGS) patients undergoing percutaneous coronary intervention (PCI) for acute coronary syndrome in the contemporary treatment era and to determine predictors of mortality.BackgroundIt is unclear whether recent advances in pharmacological and interventional strategies have resulted in further improvements in short- and long-term mortality and which factors are associated with adverse outcomes in patients presenting with CGS and undergoing PCI in the setting of acute coronary syndrome.MethodsThis study analyzed prospectively collected data for patients undergoing PCI in the setting of CGS as recorded in the BCIS (British Cardiovascular Intervention Society) PCI database.ResultsIn England and Wales, 6,489 patients underwent PCI for acute coronary syndrome in the setting of CGS. The mortality rates at 30 days, 90 days, and 1 year were 37.3%, 40.0%, and 44.3%, respectively. On multiple logistic regression analysis, age (for each 10-year increment of age: odds ratio [OR]: 1.59, 95% confidence interval [CI]: 1.51 to 1.68; p < 0.0001), diabetes mellitus (OR: 1.47, 95% CI: 1.28 to 1.70; p < 0.0001), history of renal disease (OR: 2.03, 95% CI: 1.63 to 2.53; p < 0.0001), need for artificial mechanical ventilation (OR: 2.56, 95% CI: 2.23 to 2.94; p < 0.0001), intra-aortic balloon pump use (OR: 1.57, 95% CI: 1.40 to 1.76; p < 0.0001), and need for left main stem PCI (OR: 1.90, 95% CI: 1.62 to 2.23; p < 0.0001) were associated with higher mortality at 1 year.ConclusionsIn this large U.K. cohort of patients undergoing PCI in the context of CGS, mortality remains high in spite of the use of contemporary PCI strategies. The highest mortality occurs early, and this time period may be a particular target of therapeutic intervention.  相似文献   

18.
ObjectivesThe aim of this study was to determine the incidence, predictors, and outcomes of recurrent stent thrombosis (rST).BackgroundPatients who had an initial stent thrombosis (ST) develop may be at high risk of rST.MethodsWe analyzed a multicenter California registry of angiographic definite ST at 5 academic hospitals from 2005 to 2013. A detailed review of the angiogram and procedure was performed of patients with and without rST.ResultsAmong 221 patients with a median follow-up of 3.3 years, definite or probable rST developed in 29, including 19 with angiographic definite rST. The cumulative hazard ratio (HR) of definite or probable rST was 16% at 1 year and 24% at 5 years, whereas the cumulative HR of angiographic definite rST was 11% at 1 year and 20% at 5 years. Despite similar angiographic results, patients who had rST develop had significantly greater peak creatine kinase at the time of initial ST (mean, 2,655 mg/dl vs. 1,654 mg/dl; p = 0.05) than those without rST. The 3-year rate of major adverse cardiovascular events was 50% for patients with rST compared with 22% for patients with a single ST (p = 0.01). After multivariable adjustment, independent predictors of definite/probable rST were age (HR: 1.4; 95 confidence interval [CI]: 1.1 to 1.8 per 10 years), bifurcation ST (HR: 4.4; 95% CI: 1.8 to 10.9), and proximal vessel diameter (HR: 1.8; 95% CI: 1.1 to 3.2 per millimeter).ConclusionsrST represents an important cause of long-term morbidity and mortality after an initial ST. Bifurcation ST and a larger proximal reference vessel diameter are independently associated with an increased risk of rST.  相似文献   

19.
ObjectivesThe aim of this study was to investigate the efficacy and safety of currently used drug-eluting stents (DES).BackgroundHead-to-head comparisons among newer DES have shown conflicting results.MethodsFor this network meta-analysis, randomized controlled trials comparing different types of currently used DES were searched in PubMed, Scopus, and proceedings of international meetings. The primary endpoint was target lesion failure (TLF) at 1 year and at long-term follow-up.ResultsSeventy-seven trials with 99,039 patients were selected for this network meta-analysis. Among the 10 DES included in the meta-analysis, 4 received the most extensive investigation: Orsiro, XIENCE, Nobori/BioMatrix, and Resolute. At 1 year, the Orsiro stent was associated with lower rates of TLF compared with XIENCE (odds ratio [OR]: 0.84; 95% confidence interval [CI]: 0.71 to 0.98; p = 0.03), Resolute (OR: 0.81; 95% CI: 0.68 to 0.95; p = 0.01), and Nobori/BioMatrix (OR: 0.81; 95% CI: 0.67 to 0.98; p = 0.03). Orsiro had the highest probability to be the best (70.8%), with a surface under the cumulative ranking curve value of 95.9%. However, after a median follow-up period of 50 months (range: 24 to 60 months), no significant difference was apparent in the rates of TLF between any DES, although Orsiro still ranked as the best stent (58.6% probability to be the best). In addition, Orsiro had a lower rate of long-term definite stent thrombosis compared with Nobori/BioMatrix (OR: 0.60; 95% CI: 0.36 to 0.98; p = 0.04) and lower rates of definite and probable stent thrombosis compared with Resolute (OR: 0.66; 95% CI: 0.45 to 0.99; p = 0.04). No differences in cardiac mortality between any DES were observed.ConclusionsOrsiro is associated with a lower 1-year rate of TLF compared with XIENCE, Resolute, and Nobori/BioMatrix but with an attenuation of the efficacy signal at long-term follow-up.  相似文献   

20.
ObjectivesThe purpose of this study was to assess whether the benefits conferred by radial access (RA) at an individual level are offset by a proportionally greater incidence of vascular access site complications (VASC) at a population level when femoral access (FA) is performed.BackgroundThe recent widespread adoption of RA for cardiac catheterization has been associated with increased rates of VASCs when FA is attempted.MethodsLogistic regression was used to calculate the adjusted VASC rate in a contemporary cohort of consecutive patients (2006 to 2008) where both RA and FA were used, and compared it with the adjusted VASC rate observed in a historical control cohort (1996 to 1998) where only FA was used. We calculated the adjusted attributable risk to estimate the proportion of VASC attributable to the introduction of RA in FA patients of the contemporary cohort.ResultsA total of 17,059 patients were included. At a population level, the VASC rate was higher in the overall contemporary cohort compared with the historical cohort (adjusted rates: 2.91% vs. 1.98%; odds ratio [OR]: 1.48, 95% confidence interval [CI]: 1.17 to 1.89; p = 0.001). In the contemporary cohort, RA patients experienced fewer VASC than FA patients (adjusted rates: 1.44% vs. 4.19%; OR: 0.33, 95% CI: 0.23 to 0.48; p < 0.001). We observed a higher VASC rate in FA patients in the contemporary cohort compared with the historical cohort (adjusted rates: 4.19% vs. 1.98%; OR: 2.16, 95% CI: 1.67 to 2.81; p < 0.001). This finding was consistent for both diagnostic and therapeutic catheterizations separately. The proportion of VASCs attributable to RA in the contemporary FA patients was estimated at 52.7%.ConclusionsIn a contemporary population where both RA and FA were used, the safety benefit associated with RA is offset by a paradoxical increase in VASCs among FA patients. The existence of this radial paradox should be taken into consideration, especially among trainees and default radial operators.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号