首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
ObjectivesThe aim of the current study was to compare everolimus-eluting stents (EES) with sirolimus-eluting stents (SES) in patients undergoing primary angioplasty.BackgroundDrug-eluting stents may offer benefits in terms of repeat revascularization. However, as shown for first-generation drug-eluting stents, they may be counterbalanced by a potential higher risk of stent thrombosis, especially among patients with ST-segment elevation myocardial infarction (STEMI). No data have been reported so far on the long-term benefits and safety of the new generation of drug-eluting stents in STEMI.MethodsConsecutive STEMI patients admitted within 12 h of symptom onset and undergoing primary angioplasty and stent implantation at a tertiary center with 24-h primary percutaneous coronary intervention capability were randomly assigned to SES or EES. The primary endpoint was a major adverse cardiac event at 3-year follow-up. The secondary endpoints were death, reinfarction, definite or probable stent thrombosis, and target vessel revascularization at 3-year follow-up. No patient was lost to follow-up.ResultsFrom April 2007 to May 2009, 500 patients with STEMI were randomized to EES (n = 250) or SES (n = 250). No difference was observed in terms of baseline demographic and clinical characteristics between the groups. No difference was observed between the groups in terms of number of implanted stents per patient or total stent length. However, a larger reference diameter was observed with SES (3.35 ± 0.51 mm vs. 3.25 ± 0.51 mm, p = 0.001), whereas patients randomized to EES more often received glycoprotein IIb/IIIa inhibitors (54.4% vs. 42.4%, p = 0.006). Follow-up data were available in all patients (1,095 ± 159 days). No significant difference was observed between EES and SES in major adverse cardiac events (16% vs. 20.8%, adjusted hazard ratio [HR]: 0.75 [95% confidence interval (CI): 0.5 to 1.13], p = 0.17), cardiac death (4.4% vs. 5.6%, adjusted HR: 0.77 [95% CI: 0.35 to 1.71], p = 0.53), recurrent MI (6.4% vs. 10%, adjusted HR: 0.62 [95% CI: 0.33 to 1.16], p = 0.13), and target vessel revascularization (4.8% vs. 4.8%, adjusted HR: 1.00 [95% CI: 0.45 to 2.32], p = 0.99). However, EES was associated with a significant reduction in stent thrombosis (1.6% vs. 5.2%, adjusted HR: 0.3 [95% CI: 0.1 to 0.92], p = 0.035).ConclusionsThis study shows that among STEMI patients undergoing primary angioplasty, EES has similar efficacy as SES, but is associated with a significant reduction in stent thrombosis. (Randomized Comparison of Everolimus Eluting Stents and Sirolimus Eluting Stent in Patients With ST Elevation Myocardial Infarction [RACES-MI]; NCT01684982)  相似文献   

2.
3.
4.
ObjectivesThis study sought to compare rates of stent thrombosis and major adverse cardiac and cerebrovascular events (MACCE) (composite of death, myocardial infarction, or stroke) after coronary stenting with drug-eluting stents (DES) versus bare-metal stents (BMS) in patients who participated in the DAPT (Dual Antiplatelet Therapy) study, an international multicenter randomized trial comparing 30 versus 12 months of dual antiplatelet therapy in subjects undergoing coronary stenting with either DES or BMS.BackgroundDespite antirestenotic efficacy of coronary DES compared with BMS, the relative risk of stent thrombosis and adverse cardiovascular events is unclear. Many clinicians perceive BMS to be associated with fewer adverse ischemic events and to require shorter-duration dual antiplatelet therapy than DES.MethodsProspective propensity-matched analysis of subjects enrolled into a randomized trial of dual antiplatelet therapy duration was performed. DES- and BMS-treated subjects were propensity-score matched in a many-to-one fashion. The study design was observational for all subjects 0 to 12 months following stenting. A subset of eligible subjects without major ischemic or bleeding events were randomized at 12 months to continued thienopyridine versus placebo; all subjects were followed through 33 months.ResultsAmong 10,026 propensity-matched subjects, DES-treated subjects (n = 8,308) had a lower rate of stent thrombosis through 33 months compared with BMS-treated subjects (n = 1,718, 1.7% vs. 2.6%; weighted risk difference −1.1%, p = 0.01) and a noninferior rate of MACCE (11.4% vs. 13.2%, respectively, weighted risk difference −1.8%, p = 0.053, noninferiority p < 0.001).ConclusionsDES-treated subjects have long-term rates of stent thrombosis that are lower than BMS-treated subjects. (The Dual Antiplatelet Therapy Study [DAPT study]; NCT00977938)  相似文献   

5.
6.
ObjectivesThis study sought to assess the incidence and clinical impact of stent fracture (SF) after the PROMUS Element platinum-chromium everolimus-eluting stent (PtCr-EES).BackgroundSF remains an unresolved, clinically relevant issue, even in the newer-generation drug-eluting stent era.MethodsFrom March 2012 to August 2013, 816 patients with 1,094 lesions were treated only with PtCr-EES and 700 patients (85.7%) with 898 lesions undergoing follow-up angiography within 9 months after the index procedure were analyzed. SF was defined as complete or partial separation of the stent, as assessed by plain fluoroscopy, intravascular ultrasound, or optical coherence tomography during the follow-up. We assessed the rate of SF and the cumulative incidence of clinically driven target lesion revascularization and definite stent thrombosis within 9 months after the index procedure.ResultsSF was observed in 16 of 898 lesions (1.7%) and 16 of 700 patients (2.2%). Lesions with in-stent restenosis at baseline (odds ratio [OR]: 14.2, 95% confidence intervals [CI]: 5.09 to 39.7; p < 0.001) or hinge motion (OR: 4.31, 95% CI: 1.12 to 16.5; p = 0.03), and total stent length (per 10-mm increase; OR: 1.32, 95% CI: 1.12 to 1.57; p = 0.001) were predictors of SF. Cumulative incidence of clinically driven target lesion revascularization within 9-months was numerically higher in the SF group than that in the non-SF group (18.7% vs. 2.3%). Cumulative incidence of definite stent thrombosis within 9 months after the index procedure was similar between the SF and non-SF groups (0.0% vs. 0.23%).ConclusionsSF after PtCr-EES occurs in 1.7% of lesions and appears to be associated with clinically driven target lesion revascularization.  相似文献   

7.
8.
9.
ObjectivesThis study sought to report the 5-year outcomes of everolimus-eluting stents (EES) and paclitaxel-eluting stents (PES) in an all-comers population undergoing percutaneous coronary intervention (PCI).BackgroundThe medium-term 1 and 2-year results of the prospective randomized COMPARE trial (A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice) showed superior clinical outcomes with EES compared with PES in an all-comers PCI population. Whether this benefit is sustained over longer-term follow-up is unknown. Furthermore, systematic long-term follow-up data on these metallic drug eluting stents with durable polymers are scarce.MethodsWe randomly assigned 1,800 patients undergoing PCI to EES or PES. The pre-specified composite primary endpoint was death, myocardial infarction (MI), or target vessel revascularization (TVR).ResultsFollow-up at 5 years was completed in 1,791 (99.5%) patients. Treatment with EES compared with PES led to a relative risk reduction of the primary endpoint by 27% (18.4% vs. 25.1%, p = 0.0005), driven by lower rates of MI (7.0% vs. 11.5%, p = 0.001) and TVR (7.4% vs. 11.4%, p = 0.003), but not with mortality (9.0% vs. 10.3%, relative risk 0.88, p = 0.36). Moreover, patients treated with EES compared with PES had lower rates of definite/probable stent thrombosis at 5 years (3.1% vs. 5.9%, p = 0.005). The hazard curves for TVR, MI, and stent thrombosis diverge over the first 3 years and, subsequently, progress in parallel.ConclusionsThe early- and medium-term superiority of EES over PES measured both by safety and efficacy endpoints is sustained at 5 years in this all-comer population. (A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice [COMPARE]; NCT01016041)  相似文献   

10.
ObjectivesThe aim of this study was to identify clinical, procedural, and angiographic correlates of late/very late drug-eluting stent (DES) thrombosis as well as to determine the clinical outcomes of these events.BackgroundLate/very late DES thromboses are a poorly studied phenomenon, partly due to the relative infrequency of these events, even in large cohort studies.MethodsIn the DESERT (International Drug-Eluting Stent Event Registry of Thrombosis), a retrospective, case-control registry, 492 cases of late/very late definite DES thrombosis from 21 international sites were matched in a 1:1 fashion with controls without stent thrombosis (ST). Controls were matched according to 2 criteria: same enrolling institution and date of initial DES implantation. Baseline and procedural variables were collected, and clinical follow-up was obtained for patients with ST as long as 1 year after the event. Offline quantitative coronary angiography was performed for a subset of 378 case-control pairs.ResultsThe majority of ST events occurred after 1 year (75%) and continued to occur for as long as 7.3 years. The clinical presentation of late/very late ST events was mainly myocardial infarction (66.7% ST-segment elevation myocardial infarction and 22.0% non–ST-segment elevation myocardial infarction); in-hospital mortality was 3.8%. A minority of patients (30%) with ST were receiving dual-antiplatelet therapy at the time of the event. Independent clinical correlates of late/very late ST were younger age, African-American race, current smoking, multivessel disease, longer stented length, overlapping stents, and percutaneous coronary intervention of vein graft lesions. Independent angiographic correlates for late/very late ST were lesions within the left anterior descending artery or a bypass graft, thrombus, and a larger residual diameter stenosis after the initial DES implantation. Despite the large sample of ST cases, all identified correlates of late/very late ST had weak associations with subsequent ST (all odds ratios <2.5).ConclusionsDespite a large sample of ST cases and use of limited matching to maximize the identification of predictive factors associated with late/very late ST, the variables associated with the development of late/very late ST were only weakly predictive of subsequent events. Additionally, a relatively low observed mortality rate of ST in this series may reflect a different pathophysiology of these late/very late events compared with acute/subacute ST. (Drug Eluting Stent Registry of Thrombosis [DESERT]; NCT00812552).  相似文献   

11.
ObjectivesThis study sought to evaluate the mechanism of post-procedural cardiac biomarker (CB) rise following device implantation.BackgroundA fully bioresorbable Absorb scaffold, compared with everolimus-eluting metallic stents (EES), might be associated with a higher incidence of periprocedural myocardial injury.MethodsIn 501 patients with stable or unstable angina randomized to either Absorb (335 patients) or EES (n = 166) in the ABSORB II trial, 3 types of CB (creatine kinase, creatine kinase-myocardial band, and troponin) were obtained before and after procedure. Per protocol, periprocedural myocardial infarction (PMI) was defined as creatine kinase rise >2× the upper limit of normal with creatine kinase-myocardial band rise.ResultsIncidence of side branch occlusion and any anatomic complications assessed by angiography was similar between the 2 treatment arms (side branch occlusion: Absorb: 5.3% vs. Xience: 7.6%, p = 0.07; any anatomic complication: Absorb: 16.4% vs. EES: 19.9%, p = 0.39). Fourteen patients who presented with recent myocardial infarction at entry with normalized creatine kinase-myocardial band according to the protocol were excluded for post-CB analysis. The overall compliance for CB was 97.8%. The CB rise subcategorized in 7 different ranges was comparable between the 2 treatment arms. PMI rate was numerically higher in the Absorb arm according to the per-protocol definitions, and treatment with overlapping devices was the only independent determinant of per-protocol PMI (odds ratio: 5.07, 95% confidence interval: 1.78 to 14.41, p = 0.002).ConclusionsThere were no differences in the incidence of CB rise and PMI between Absorb and EES. Device overlap might be a precipitating factor of myocardial injury. (ABSORB II Randomized Clinical Trial: A Clinical Evaluation to Compare the Safety, Efficacy, and Performance of Absorb Everolimus Eluting Bioresorbable Vascular Scaffold System Against Xience Everolimus Eluting Coronary Stent System in the Treatment of Subjects With Ischemic Heart Disease Caused by De Novo Native Coronary Artery Lesions [ABSORB II]; NCT01425281).  相似文献   

12.
ObjectivesThis study examined whether coronary angioscopy-verified in-stent yellow plaque at 1 year after drug-eluting stent (DES) implantation is associated with future event of very late stent failure (VLSF).BackgroundAtherosclerosis detected as yellow plaque by angioscopy has been associated with future events of acute coronary syndrome. Development of in-stent neoatherosclerosis is a probable mechanism of VLSF.MethodsThis study included 360 consecutive patients who received successful angioscopic examination at 1 year after implantation of a DES. They were clinically followed up for VLSF defined as cardiac death, acute myocardial infarction or unstable angina, or need for revascularization associated with the stent site.ResultsThe follow-up interval was 1,558 ± 890 days (4.3 ± 2.4 years). The incidence of VLSF was significantly higher in the patients with yellow plaque than in those without (8.1% vs. 1.6%; log rank p = 0.02). Multivariable analysis revealed the presence of yellow plaque (hazard ratio [HR]: 5.38; p = 0.02) and absence of statin therapy (HR: 3.25; p = 0.02) as risks of VLSF.ConclusionsIn-stent atherosclerosis evaluated by yellow plaque at 1 year after the implantation of DES and the absence of statin therapy were risks of VLSF. The underlying mechanism of VLSF appeared to be the progression of atherosclerosis as demonstrated by the yellow plaque.  相似文献   

13.
ObjectivesThe study sought to compare the risk of late outcome with a focus on very late definite stent thrombosis of the everolimus-eluting stent (EES) with that of the sirolimus-eluting stent (SES) at 3-year follow-up.BackgroundIn the SORT OUT IV (SORT OUT IV Trial), comparing the EES with the SES in patients with coronary artery disease, the EES was noninferior to the SES at 9 months. The SORT OUT IV trial provides long-term head-to-head randomized comparison of the EES with the SES.MethodsWe prospectively randomized 2,774 patients in the SORT OUT IV trial. Follow-up through 3 years was complete in 2,771 patients (99.9%). The 3-year pre-specified endpoints were composites of safety and efficacy (major adverse cardiac events [MACE]: cardiac death, myocardial infarction, target vessel revascularization, and definite stent thrombosis).ResultsAt 3 years, the composite endpoint MACE occurred in 9.8% of the EES group and in 11.1% of the SES group (hazard ratio [HR]: 0.89, 95% confidence interval [CI]: 0.70 to 1.12). Overall rate of definite stent thrombosis was lower in the EES group (0.2% vs. 1.4%; HR: 0.15, 95% CI: 0.04 to 0.50), which was largely attributable to a lower risk of very late definite stent thrombosis: 0.1% versus 0.8% (HR: 0.09, 95% CI: 0.01 to 0.70).ConclusionsAt 3-year follow-up, the MACE rate did not differ significantly between EES- and SES-treated patients. A significant reduction of overall and very late definite stent thrombosis was found in the EES group. (The SORT OUT IV TRIAL [SORT OUT IV]; NCT00552877).  相似文献   

14.
15.
ObjectivesThis study aimed to investigate the clinical outcomes of patients presenting with recurrent drug-eluting stent (DES) in-stent restenosis (ISR) treated with a second-generation DES or with a drug-coated balloon (DCB).BackgroundTo date, there are no reports of DCB treatment and limited data with regard to the efficacy of further DES implantation for recurrent ISR.MethodsBetween January 2008 and December 2013, 171 lesions were assessed for eligibility (82 lesions in the second-generation DES group and 89 lesions in the DCB group).ResultsAcute gain was greater in the second-generation DES group (second-generation DES, 2.09 ± 0.53 mm vs. DCBs, 1.60 ± 0.62 mm, p < 0.001). The rates of major adverse cardiac events were comparable (at 1 year, DES 14.0% vs. DCBs 12.3%; at 2 years, DES 28.8% vs. DCBs 43.5%, p = 0.21). Major adverse cardiac event rates were mainly driven by target lesion revascularization (at 1 year, DES 12.5% vs. DCBs 10.9%; at 2 years, DES 27.7% vs. DCBs 38.3%; p = 0.40). Definite scaffold thrombosis occurred in 2 patients (1 patient in each group). Multivariable analysis revealed ISR recurrence within 1 year (hazard ratio: 2.43, 95% confidence interval: 1.14 to 5.18, p = 0.02) and lesion length (per 10-mm increase) (hazard ratio: 1.15, 95% confidence interval: 1.00 to 1.32, p = 0.049) to be independent predictors of TLR.ConclusionsThe results after both treatments were equivalent. ISR recurrence within 1 year of the first reintervention and lesion length were independent predictors of future target lesion revascularization. Larger studies are required to confirm the late (>1 year) differences with regard to clinical outcomes.  相似文献   

16.
17.
18.
19.
ObjectivesThis study sought to evaluate procedural and clinical outcomes among patients undergoing chronic total occlusion (CTO) percutaneous coronary intervention (PCI) using contemporary methods and everolimus-eluting stents (EES).BackgroundLimited studies have detailed the procedural and late-term safety and efficacy of CTO revascularization among multiple centers applying modern techniques and with newer-generation drug-eluting stents.MethodsAmong 20 centers, 250 consecutive patients were enrolled for attempted CTO PCI. Procedural and in-hospital clinical outcomes were examined in addition to the 1-year primary endpoint of death, myocardial infarction, and target lesion revascularization (major adverse cardiac events [MACE]).ResultsDemographic, lesion, and procedural characteristics included prior bypass surgery: 9.9%; diabetes: 40.1%; lesion length: 36.1 ± 18.5 mm; and stent length: 51.7 ± 27.2 mm. Procedural success, defined as guidewire recanalization with no in-hospital MACE, was 96.4%. Success with antegrade-only methods was 97.9% and 86.2% by retrograde/combined methods, respectively. Compared with a pre-specified performance goal derived from 6 prior CTO drug-eluting stent trials (1-year MACE: 24.4%), treatment with EES was associated with significantly lower composite adverse events for both intent-to-treat (18.5%, 1-sided upper confidence interval: 23.4%, p = 0.025) and per-protocol populations (8.2%, 1-sided upper confidence interval: 12.3%, p < 0.0001). Target lesion revascularization at 1 year was 6.3%. Dual antiplatelet therapy adherence was 53.9% at 1 year, yet subacute definite stent thrombosis occurred in only 2 patients (0.9%), and late probable stent thrombosis occurred in 1 patient (0.5%).ConclusionsIn a multicenter registration trial representing contemporary technique and EES, favorable procedural success and late-term clinical outcomes support CTO PCI in a patient population with high lesion complexity. (EXPERT CTO: Evaluation of the XIENCE PRIME LL and XIENCE Nano Everolimus Eluting Coronary Stent Coronary Stents, Performance, and Technique in Chronic Total Occlusions; NCT01435031)  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号