1.
ObjectivesThis study investigated the impact of final kissing ballooning (FKB) after main vessel (MV) stenting on outcomes in patients with coronary bifurcation lesions after application of the 1-stent technique.BackgroundAlthough FKB has been established as the standard method for bifurcation lesions treated with a 2-stent strategy, its efficacy in a 1-stent approach is highly controversial.MethodsThis study enrolled 1,901 patients with a bifurcation lesion with a side branch diameter ≥2.3 mm, treated solely with the 1-stent technique using a drug-eluting stent from 18 centers in Korea between January 1, 2003 and December 31, 2009. The primary outcome was major adverse cardiac events (MACE)—cardiac death, myocardial infarction, or target lesion revascularization. Propensity score-matching analysis was also performed.ResultsFKB was performed in 620 patients and the post minimal lumen diameter of the MV and side branch was larger in the FKB group than in the non-FKB group. During follow-up (median 36 months), the incidence of MACE (adjusted hazard ratio [HR]: 0.68, 95% confidence interval [CI]: 0.46 to 0.99; p = 0.048) was lower in the FKB group than the non-FKB group. After propensity score matching (545 pairs), the FKB group had a lower incidence of MACE (adjusted HR: 0.50, 95% CI: 0.30 to 0.85; p = 0.01), and target lesion revascularization in the MV (adjusted HR: 0.51, 95% CI: 0.28 to 0.93; p = 0.03) and both vessels (adjusted HR: 0.47, 95% CI: 0.25 to 0.90; p = 0.02) than in the non-FKB group.ConclusionsIn coronary bifurcation lesions, we demonstrated that the 1-stent technique with FKB was associated with a favorable long-term clinical outcome, mainly driven by the reduction of target lesion revascularization in the MV or both vessels as a result of an increase in minimal lumen diameter. (Korean Coronary Bifurcation Stenting Registry II [COBIS II]: NCT01642992)  相似文献   

2.
ObjectivesThis study sought to investigate the long-term comparative efficacy and safety of paclitaxel-eluting balloon (PEB), paclitaxel-eluting stent (PES), or balloon angioplasty (BA) for the treatment of drug-eluting stent restenosis.BackgroundThe optimal treatment of drug-eluting stent restenosis remains unknown. Although PEB has shown encouraging results, the long-term clinical efficacy and safety of PEB remains poorly defined.MethodsA total of 402 patients with clinically significant restenosis in limus-eluting stents were randomly assigned to receive PEB (n = 137), PES (n = 131), or BA (n = 134). For this analysis, PEB versus PES and PEB versus BA were compared. The primary efficacy and safety endpoints were target lesion revascularization and the composite of death or myocardial infarction.ResultsAt a median follow-up of 3 years, the risk of target lesion revascularization was comparable with PEB versus PES (hazard ratio [HR]: 1.46, 95% confidence interval [CI]: 0.91 to 2.33; p = 0.11) and lower with PEB versus BA (HR: 0.51, 95% CI: 0.34 to 0.74; p < 0.001). The risk of death/myocardial infarction tended to be lower with PEB versus PES (HR: 0.55, 95% CI: 0.28 to 1.07; p = 0.08), due to a lower risk of death (HR: 0.38, 95% CI: 0.17 to 0.87; p = 0.02). The risk of death/myocardial infarction was similar with PEB versus BA (HR: 0.96, 95% CI: 0.46 to 2.0; p = 0.91).ConclusionsAt 3 years, the use of PEB as compared with PES to treat patients with limus-eluting stent restenosis has similar efficacy and safety. PEB remains superior to BA. The sustained efficacy without trade-off in safety supports the role of PEB as treatment option for patients with drug-eluting stent restenosis. (Intracoronary Stenting and Angiographic Results: Drug Eluting Stent In-Stent Restenosis: 3 Treatment Approaches [ISAR-DESIRE 3]; NCT00987324)  相似文献   

3.
ObjectivesThe aim of this study was to investigate the correlation between in-stent neointimal tissue without features of neoatherosclerosis and long-term clinical outcomes.BackgroundRecent studies have reported differential morphological characteristics of in-stent neointimal tissue assessed by optical coherence tomography (OCT).MethodsThe study population consisted of 336 patients with 368 drug-eluting stent-treated lesions. Patients received a follow-up OCT examination without any intervention. OCT-based neointima was categorized as homogeneous (n = 227 lesions in 208 patients), heterogeneous (n = 79 lesions in 73 patients), or layered (n = 62 lesions in 55 patients). Major adverse cardiac events (MACE) (a composite of cardiac death, nonfatal myocardial infarction, or target lesion revascularization) were assessed according to neointimal patterns during long-term clinical follow-up after OCT examination.ResultsThe time interval between stent implantation and OCT examination was similar among the 3 groups (p = 0.64). On multivariate logistic regression analysis, the significant determinant for the heterogeneous neointima was age (odds ratio [OR]: 1.037, 95% confidence interval [CI]: 1.007 to 1.068, p = 0.015) and an initial clinical presentation of acute coronary syndrome (OR: 1.967, 95% CI: 1.159 to 3.339, p = 0.012). The overall median follow-up duration for all patients after follow-up OCT examination was 31.0 months, and this was statistically different among the heterogeneous group (22.0 months), the homogeneous group (34.0 months), and the layered group (28.0 months, overall p = 0.002). MACE occurred more frequently in patients with heterogeneous neointima over a median 31-month follow-up period after OCT examination (13.7% vs. 2.9% in homogeneous vs. 7.3% in layered, p = 0.001). A propensity score–adjusted Cox regression analysis showed that independent risk factors for MACE were inclusion in the heterogeneous neointima (hazard ratio: 3.925, 95% CI: 1.445 to 10.662, p = 0.007) and minimal lumen cross-sectional area (hazard ratio: 0.368, 95% CI: 0.242 to 0.560, p < 0.001).ConclusionsDetermination of neointimal characteristics is helpful in predicting long-term clinical outcomes. Our data suggest that heterogeneous lesions are linked to poor long-term clinical prognoses.  相似文献   

4.
ObjectivesThis study aimed to investigate the clinical outcomes of patients presenting with recurrent drug-eluting stent (DES) in-stent restenosis (ISR) treated with a second-generation DES or with a drug-coated balloon (DCB).BackgroundTo date, there are no reports of DCB treatment and limited data with regard to the efficacy of further DES implantation for recurrent ISR.MethodsBetween January 2008 and December 2013, 171 lesions were assessed for eligibility (82 lesions in the second-generation DES group and 89 lesions in the DCB group).ResultsAcute gain was greater in the second-generation DES group (second-generation DES, 2.09 ± 0.53 mm vs. DCBs, 1.60 ± 0.62 mm, p < 0.001). The rates of major adverse cardiac events were comparable (at 1 year, DES 14.0% vs. DCBs 12.3%; at 2 years, DES 28.8% vs. DCBs 43.5%, p = 0.21). Major adverse cardiac event rates were mainly driven by target lesion revascularization (at 1 year, DES 12.5% vs. DCBs 10.9%; at 2 years, DES 27.7% vs. DCBs 38.3%; p = 0.40). Definite scaffold thrombosis occurred in 2 patients (1 patient in each group). Multivariable analysis revealed ISR recurrence within 1 year (hazard ratio: 2.43, 95% confidence interval: 1.14 to 5.18, p = 0.02) and lesion length (per 10-mm increase) (hazard ratio: 1.15, 95% confidence interval: 1.00 to 1.32, p = 0.049) to be independent predictors of TLR.ConclusionsThe results after both treatments were equivalent. ISR recurrence within 1 year of the first reintervention and lesion length were independent predictors of future target lesion revascularization. Larger studies are required to confirm the late (>1 year) differences with regard to clinical outcomes.  相似文献   

5.
ObjectivesThe aim of the current study was to compare everolimus-eluting stents (EES) with sirolimus-eluting stents (SES) in patients undergoing primary angioplasty.BackgroundDrug-eluting stents may offer benefits in terms of repeat revascularization. However, as shown for first-generation drug-eluting stents, they may be counterbalanced by a potential higher risk of stent thrombosis, especially among patients with ST-segment elevation myocardial infarction (STEMI). No data have been reported so far on the long-term benefits and safety of the new generation of drug-eluting stents in STEMI.MethodsConsecutive STEMI patients admitted within 12 h of symptom onset and undergoing primary angioplasty and stent implantation at a tertiary center with 24-h primary percutaneous coronary intervention capability were randomly assigned to SES or EES. The primary endpoint was a major adverse cardiac event at 3-year follow-up. The secondary endpoints were death, reinfarction, definite or probable stent thrombosis, and target vessel revascularization at 3-year follow-up. No patient was lost to follow-up.ResultsFrom April 2007 to May 2009, 500 patients with STEMI were randomized to EES (n = 250) or SES (n = 250). No difference was observed in terms of baseline demographic and clinical characteristics between the groups. No difference was observed between the groups in terms of number of implanted stents per patient or total stent length. However, a larger reference diameter was observed with SES (3.35 ± 0.51 mm vs. 3.25 ± 0.51 mm, p = 0.001), whereas patients randomized to EES more often received glycoprotein IIb/IIIa inhibitors (54.4% vs. 42.4%, p = 0.006). Follow-up data were available in all patients (1,095 ± 159 days). No significant difference was observed between EES and SES in major adverse cardiac events (16% vs. 20.8%, adjusted hazard ratio [HR]: 0.75 [95% confidence interval (CI): 0.5 to 1.13], p = 0.17), cardiac death (4.4% vs. 5.6%, adjusted HR: 0.77 [95% CI: 0.35 to 1.71], p = 0.53), recurrent MI (6.4% vs. 10%, adjusted HR: 0.62 [95% CI: 0.33 to 1.16], p = 0.13), and target vessel revascularization (4.8% vs. 4.8%, adjusted HR: 1.00 [95% CI: 0.45 to 2.32], p = 0.99). However, EES was associated with a significant reduction in stent thrombosis (1.6% vs. 5.2%, adjusted HR: 0.3 [95% CI: 0.1 to 0.92], p = 0.035).ConclusionsThis study shows that among STEMI patients undergoing primary angioplasty, EES has similar efficacy as SES, but is associated with a significant reduction in stent thrombosis. (Randomized Comparison of Everolimus Eluting Stents and Sirolimus Eluting Stent in Patients With ST Elevation Myocardial Infarction [RACES-MI]; NCT01684982)  相似文献   

6.
ObjectivesThis study examined whether coronary angioscopy-verified in-stent yellow plaque at 1 year after drug-eluting stent (DES) implantation is associated with future event of very late stent failure (VLSF).BackgroundAtherosclerosis detected as yellow plaque by angioscopy has been associated with future events of acute coronary syndrome. Development of in-stent neoatherosclerosis is a probable mechanism of VLSF.MethodsThis study included 360 consecutive patients who received successful angioscopic examination at 1 year after implantation of a DES. They were clinically followed up for VLSF defined as cardiac death, acute myocardial infarction or unstable angina, or need for revascularization associated with the stent site.ResultsThe follow-up interval was 1,558 ± 890 days (4.3 ± 2.4 years). The incidence of VLSF was significantly higher in the patients with yellow plaque than in those without (8.1% vs. 1.6%; log rank p = 0.02). Multivariable analysis revealed the presence of yellow plaque (hazard ratio [HR]: 5.38; p = 0.02) and absence of statin therapy (HR: 3.25; p = 0.02) as risks of VLSF.ConclusionsIn-stent atherosclerosis evaluated by yellow plaque at 1 year after the implantation of DES and the absence of statin therapy were risks of VLSF. The underlying mechanism of VLSF appeared to be the progression of atherosclerosis as demonstrated by the yellow plaque.  相似文献   

7.
ObjectivesThe aim of this study was to investigate the hypothesis that a novel biodegradable polymer–coated, cobalt-chromium (CoCr), sirolimus-eluting stent (BP-SES) is noninferior in safety and efficacy outcomes compared with a durable polymer (DP)-SES.BackgroundNo randomized trials have the compared safety and efficacy of BP-SES versus DP-SES on similar CoCr platforms, thereby isolating the effect of the polymer type.MethodsIn this prospective, single-blind, randomized trial conducted at 32 Chinese sites, 2,737 patients eligible for coronary stenting were treated with BP- or DP-SES in a 2:1 ratio. The primary endpoint was 12-month target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction, or clinically indicated target lesion revascularization. Secondary endpoints included TLF components, and definite/probable stent thrombosis.ResultsAt 12 months, the difference in the primary endpoint of TLF between BP-SES (6.3%) and DP-SES (6.1%) groups was 0.25% (95% confidence interval: −1.67% to 2.17%, p for noninferiority = 0.0002), demonstrating noninferiority of BP-SES to DP-SES. Individual TLF components of cardiac death (0.7% vs. 0.6%, p = 0.62), target vessel myocardial infarction (3.6% vs. 4.3%, p = 0.39), and clinically indicated target lesion revascularization (2.6% vs. 2.2%, p = 0.50) were similar, as were low definite/probable stent thrombosis rates (0.4% vs. 0.6%, p = 0.55).ConclusionsIn this large-scale real-world trial, BP-SES was noninferior to DP-SES for 1-year TLF. (Evaluate Safety and Effectiveness of the Tivoli ® DES and the Firebird ® DES for Treatment of Coronary Revascularization; NCT01681381)  相似文献   

8.
ObjectivesThe present study established criteria to differentiate simple from complex bifurcation lesions and compared 1-year outcomes stratified by lesion complexity after provisional stenting (PS) and 2-stent techniques using drug-eluting stents.BackgroundCurrently, no criterion can distinguish between simple and complex coronary bifurcation lesions. Comparisons of PS and 2-stent strategies stratified by lesion complexity have also not been reported previously.MethodsCriteria of bifurcation complexity in 1,500 patients were externally tested in another 3,660 true bifurcation lesions after placement of drug-eluting stents. The primary endpoint was the occurrence of a major adverse cardiac event (MACE) at 12 months. The secondary endpoint was the rate of stent thrombosis (ST).ResultsComplex (n = 1,108) bifurcation lesions were associated with a higher 1-year rate of MACE (16.8%) compared with simple (n = 2,552) bifurcation lesions (8.9%) (p < 0.001). The in-hospital ST and 1-year target lesion revascularization rates after 2-stent techniques in the simple group (1.0% and 5.6%, respectively) were significantly different from those after PS (0.2% [p = 0.007] and 3.2% [p = 0.009], respectively); however, 1-year MACE rates were not significantly different between the 2 groups. For complex bifurcation lesions, 2-stent techniques had lower rates of 1-year cardiac death (2.8%) and in-hospital MACE (5.0%) compared with PS (5.3%, p = 0.047; 8.4%, p = 0.031).ConclusionsComplex bifurcation lesions had higher rates of 1-year MACE and ST. The 2-stent and PS techniques were overall equivalent in 1-year MACE. However, 2-stent techniques for complex lesions elicited a lower rate of cardiac death and in-hospital MACE but higher rates of in-hospital ST and revascularization at 1 year for simple lesions.  相似文献   

9.
ObjectivesThis study sought to compare the outcomes of fractional flow reserve (FFR)–guided and angiography (Angio)–guided provisional side-branch (SB) stenting for true coronary bifurcation lesions.BackgroundAngio-guided provisional SB stenting after stenting of the main vessel provides favorable outcomes for the majority of coronary bifurcation lesions. Whether an FFR-guided provisional stenting approach is superior has not been studied.MethodsA total of 320 patients with single Medina 1,1,1 and 0,1,1 coronary bifurcation lesions undergoing stenting with a provisional SB approach were randomly assigned 1:1 to Angio-guided and FFR-guided groups. SB stenting was performed for Thrombolysis In Myocardial Infarction flow grade <3, ostial SB stenosis >70%, or greater than type A dissection after main vessel stenting in the Angio-guided group and for SB-FFR <0.80 in the FFR-guided group. The primary endpoint was the 1-year composite rate of major adverse cardiac events (cardiac death, myocardial infarction, and clinically driven target vessel revascularization).ResultsComparing the Angio-guided and FFR-guided groups, treatment of the SB (balloon or stenting) was performed in 63.1% and 56.3% of lesions respectively (p = 0.07); stenting of the SB was attempted in 38.1% and 25.9%, respectively (p = 0.01); and, when attempted, stenting was successful in 83.6% and 73.3% of SBs, respectively (p = 0.01). The 1-year composite major adverse cardiac event rate was 18.1% in both groups (hazard ratio: 0.91, 95% confidence interval: 0.48 to 1.88; p = 1.00). The 1-year target vessel revascularization and stent thrombosis rates were 6.9% and 5.6% (p = 0.82) and 1.3% and 0.6% (p = 0.56) in the Angio-guided and FFR-guided groups, respectively.ConclusionsIn this multicenter, randomized trial, angiographic and FFR guidance of provisional SB stenting of true coronary bifurcation lesions provided similar 1-year clinical outcomes. (Randomized Study on DK Crush Technique Versus Provisional Stenting Technique for Coronary Artery Bifurcation Lesions; ChiCTR-TRC-07000015)  相似文献   

10.
ObjectivesThis study sought to evaluate procedural and clinical outcomes among patients undergoing chronic total occlusion (CTO) percutaneous coronary intervention (PCI) using contemporary methods and everolimus-eluting stents (EES).BackgroundLimited studies have detailed the procedural and late-term safety and efficacy of CTO revascularization among multiple centers applying modern techniques and with newer-generation drug-eluting stents.MethodsAmong 20 centers, 250 consecutive patients were enrolled for attempted CTO PCI. Procedural and in-hospital clinical outcomes were examined in addition to the 1-year primary endpoint of death, myocardial infarction, and target lesion revascularization (major adverse cardiac events [MACE]).ResultsDemographic, lesion, and procedural characteristics included prior bypass surgery: 9.9%; diabetes: 40.1%; lesion length: 36.1 ± 18.5 mm; and stent length: 51.7 ± 27.2 mm. Procedural success, defined as guidewire recanalization with no in-hospital MACE, was 96.4%. Success with antegrade-only methods was 97.9% and 86.2% by retrograde/combined methods, respectively. Compared with a pre-specified performance goal derived from 6 prior CTO drug-eluting stent trials (1-year MACE: 24.4%), treatment with EES was associated with significantly lower composite adverse events for both intent-to-treat (18.5%, 1-sided upper confidence interval: 23.4%, p = 0.025) and per-protocol populations (8.2%, 1-sided upper confidence interval: 12.3%, p < 0.0001). Target lesion revascularization at 1 year was 6.3%. Dual antiplatelet therapy adherence was 53.9% at 1 year, yet subacute definite stent thrombosis occurred in only 2 patients (0.9%), and late probable stent thrombosis occurred in 1 patient (0.5%).ConclusionsIn a multicenter registration trial representing contemporary technique and EES, favorable procedural success and late-term clinical outcomes support CTO PCI in a patient population with high lesion complexity. (EXPERT CTO: Evaluation of the XIENCE PRIME LL and XIENCE Nano Everolimus Eluting Coronary Stent Coronary Stents, Performance, and Technique in Chronic Total Occlusions; NCT01435031)  相似文献   

11.
ObjectivesThis study sought to investigate the clinical outcomes based on the assessment of quantitative coronary angiography–maximal lumen diameter (Dmax).BackgroundAssessment of pre-procedural Dmax of proximal and distal sites has been used for Absorb scaffold size selection in the ABSORB studies.MethodsA total of 1,248 patients received Absorb scaffolds in the ABSORB Cohort B (ABSORB Clinical Investigation, Cohort B) study (N = 101), ABSORB EXTEND (ABSORB EXTEND Clinical Investigation) study (N = 812), and ABSORB II (ABSORB II Randomized Controlled Trial) trial (N = 335). The incidence of major adverse cardiac events (MACE) (a composite of cardiac death, any myocardial infarction [MI], and ischemia-driven target lesion revascularization) was analyzed according to the Dmax subclassification of scaffold oversize group versus scaffold nonoversize group.ResultsOf 1,248 patients, pre-procedural Dmax was assessed in 1,232 patients (98.7%). In 649 (52.7%) patients, both proximal and distal Dmax values were smaller than the nominal size of the implanted scaffold (scaffold oversize group), whereas in 583 (47.3%) of patients, the proximal and/or distal Dmax were larger than the implanted scaffold (scaffold nonoversize group). The rates of MACE and MI at 1 year were significantly higher in the scaffold oversize group than in the scaffold nonoversize group (MACE 6.6% vs. 3.3%; log-rank p < 0.01, all MI: 4.6% vs. 2.4%; log-rank p = 0.04), mainly driven by a higher MI rate within 1 month post-procedure (3.5% vs. 1.9%; p = 0.08). The independent MACE determinants were both Dmax smaller than the scaffold nominal size (odds ratio [OR]: 2.13, 95% confidence interval [CI]: 1.22 to 3.70; p < 0.01) and the implantation of overlapping scaffolds (OR: 2.10, 95% CI: 1.17 to 3.80; p = 0.01).ConclusionsImplantation of an oversized Absorb scaffold in a relatively small vessel appears to be associated with a higher 1-year MACE rate driven by more frequent early MI. (ABSORB Clinical Investigation, Cohort B [ABSORB Cohort B], NCT00856856; ABSORB EXTEND Clinical Investigation [ABSORB EXTEND], NCT01023789; ABSORB II Randomized Controlled Trial [ABSORB II], NCT01425281)  相似文献   

12.
ObjectivesThe intention this PEPCAD-DES (Treatment of Drug-eluting Stent [DES] In-Stent Restenosis With SeQuent Please Paclitaxel Eluting Percutaneous Transluminal Coronary Angioplasty [PTCA] Catheter) study update was to demonstrate the safety and efficacy of paclitaxel-coated balloon (PCB) angioplasty in patients with DES-ISR at 3 years.BackgroundIn the PEPCAD-DES trial late lumen loss and the need for repeat target lesion revascularization (TLR) was significantly reduced with PCB angioplasty compared with plain old balloon angioplasty (POBA) in patients with drug-eluting stent in-stent restenosis (DES-ISR) at 6 months. We evaluated whether the clinical benefit of reduced TLR and major adverse cardiac events (MACE) was maintained up to 3 years.MethodsA total of 110 patients with DES-ISR in native coronary arteries with reference diameters ranging from 2.5 mm to 3.5 mm and lesion lengths ≤22 mm were randomized to treatment with either PCB or POBA in a multicenter, randomized, single-blind clinical study. With a 2:1 randomization, 72 patients were randomized to the PCB group and 38 patients to the POBA group. At baseline, there were lesions with at least 2 stent layers in PCB (52.8%, 38 of 72) and POBA (55.3%, 21 of 38) patients.ResultsAt 36 months, the TLR rates were significantly lower in the PCB group compared with the POBA control group (19.4% vs. 36.8%; p = 0.046). Multiple TLRs in individual patients were more frequent in the POBA group compared with the PCB group (more than 1 TLR: POBA, 13.2%; PCB, 1.4%; p = 0.021). The 36-month MACE rate was significantly reduced in the PCB group compared with the POBA group (20.8% vs. 52.6%, log-rank p = 0.001).ConclusionsPCB angioplasty was superior to POBA for the treatment of DES-ISR patients in terms of MACE and TLR for up to 36 months. There was no late catch-up phenomenon. (Treatment of Drug-eluting Stent [DES] In-Stent Restenosis With SeQuent® Please Paclitaxel Eluting Percutaneous Transluminal Coronary Angioplasty [PTCA] Catheter [PEPCAD-DES]; NCT00998439)  相似文献   

13.
ObjectivesThe aim of this study was to assess outcomes after percutaneous coronary intervention (PCI) with stents in patients treated with thoracic external beam radiation therapy (EBRT).BackgroundThoracic EBRT for cancer is associated with long-term cardiotoxic sequelae. The impact of EBRT on patients requiring coronary stents is unclear.MethodsWe analyzed outcomes after PCI in cancer survivors treated with curative thoracic EBRT before and after stenting between 1998 and 2012. Reference groups were propensity-matched cohorts with stenting but no EBRT. Primary endpoint was target lesion revascularization (TLR), a clinical surrogate for restenosis. Secondary endpoints included myocardial infarction (MI) and cardiac and overall mortality.ResultsWe identified 115 patients treated with EBRT a median 3.6 years after stenting (group A) and 45 patients treated with EBRT a median 2.2 years before stenting (group B). Long-term mean TLR rates in group A (3.2 vs. 6.6%; hazard ratio: 0.6; 95% confidence interval: 0.2 to 1.6; p = 0.31) and group B (9.2 vs. 9.7%; hazard ratio: 1.2; 95% confidence interval: 0.4 to 3.4; p = 0.79) were similar to rates in corresponding control patients (group A: 1,390 control patients; group B: 439 control patients). Three years post-PCI, group A had higher overall mortality (48.6% vs. 13.9%; p < 0.001) but not MI (4.8% vs. 4.3%; p = 0.93) or cardiac mortality (2.3% vs. 3.6%; p = 0.66) rates versus control patients. There were no significant differences in MI, cardiac, or overall mortality rates in group B.ConclusionsThoracic EBRT is not associated with increased stent failure rates when used before or after PCI. A history of PCI should not preclude the use of curative thoracic EBRT in cancer patients or vice versa. Optimal treatment of cancer should be the goal.  相似文献   

14.
ObjectivesThis study sought to assess the frequency and clinical impact of dual antiplatelet therapy (DAPT) nonadherence.BackgroundThere are limited data on the impact of DAPT nonadherence during the first year after a second-generation drug-eluting stent placement.MethodsAfter successful Endeavor zotarolimus-eluting stent implantation, 2,265 patients were enrolled in a registry with limited exclusions and monitored during 12 months of prescribed DAPT. Predictors of any nonadherence (ANA) at 6 months were analyzed by multivariable analysis, and the association between ANA at 6 or 12 months with the endpoints of death, myocardial infarction, and stent thrombosis was assessed.ResultsThe study population included 30% female patients, 34% with diabetes and 36% with acute coronary syndromes. ANA occurred in 208 patients (9.6%) before 6 months and 378 patients (18.5%) before 1 year. Major bleeding (odds ratio [OR]: 12.83, 95% confidence interval [CI]: 7.55 to 21.80, p < 0.001) was the only predictor of ANA at 6 months. In time-dependent analyses, ANA before 6 months was associated with an increased risk of death or myocardial infarction (7.6% vs. 3.0%, p < 0.001) and a numerical increase in stent thrombosis (2.0% vs. 0.9%, p = 0.12). After adjustment for baseline differences, ANA within 6 months remained associated with death or MI (OR: 1.95, 95% CI: 1.02 to 3.75). ANA occurring after 6 months did not increase the risk of subsequent ischemic events.ConclusionsDAPT ANA occurs frequently and is associated with increased risk for thrombotic complications if it occurs within the first 6 months. Major bleeding was a significant correlate of DAPT ANA within 6 months. (EDUCATE: The MEDTRONIC Endeavor Drug Eluting Stenting: Understanding Care, Antiplatelet Agents and Thrombotic Events; NCT01069003)  相似文献   

15.
ObjectivesThis study sought to report the 5-year outcomes of everolimus-eluting stents (EES) and paclitaxel-eluting stents (PES) in an all-comers population undergoing percutaneous coronary intervention (PCI).BackgroundThe medium-term 1 and 2-year results of the prospective randomized COMPARE trial (A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice) showed superior clinical outcomes with EES compared with PES in an all-comers PCI population. Whether this benefit is sustained over longer-term follow-up is unknown. Furthermore, systematic long-term follow-up data on these metallic drug eluting stents with durable polymers are scarce.MethodsWe randomly assigned 1,800 patients undergoing PCI to EES or PES. The pre-specified composite primary endpoint was death, myocardial infarction (MI), or target vessel revascularization (TVR).ResultsFollow-up at 5 years was completed in 1,791 (99.5%) patients. Treatment with EES compared with PES led to a relative risk reduction of the primary endpoint by 27% (18.4% vs. 25.1%, p = 0.0005), driven by lower rates of MI (7.0% vs. 11.5%, p = 0.001) and TVR (7.4% vs. 11.4%, p = 0.003), but not with mortality (9.0% vs. 10.3%, relative risk 0.88, p = 0.36). Moreover, patients treated with EES compared with PES had lower rates of definite/probable stent thrombosis at 5 years (3.1% vs. 5.9%, p = 0.005). The hazard curves for TVR, MI, and stent thrombosis diverge over the first 3 years and, subsequently, progress in parallel.ConclusionsThe early- and medium-term superiority of EES over PES measured both by safety and efficacy endpoints is sustained at 5 years in this all-comer population. (A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice [COMPARE]; NCT01016041)  相似文献   

16.
ObjectivesThis study sought to evaluate the intravascular ultrasound (IVUS) minimal lumen area (MLA) for functionally significant left main coronary artery (LMCA) stenosis using fractional flow reserve (FFR) as the standard.BackgroundThe evaluation of significant LMCA stenosis remains challenging.MethodsWe identified 112 patients with isolated ostial and shaft intermediate LMCA stenosis (angiographic diameter stenosis of 30% to 80%) who underwent IVUS and FFR measurement.ResultsThe FFR was ≤0.80 in 66 LMCA lesions (59%); these exhibited smaller reference vessels, smaller minimal lumen diameter, greater diameter of stenosis, longer lesion length, smaller MLA, larger plaque burden, and more frequent plaque rupture. The independent factors of an FFR of ≤0.80 were plaque rupture (odds ratio [OR]: 4.47; 95% Confidence Interval (CI): 1.35 to 14.8; p = 0.014); body mass index (OR: 1.19; 95% CI: 1.00 to 1.41; p = 0.05), age (OR: 0.95; 95% CI: 0.90 to 1.00; p = 0.031), and IVUS MLA (OR: 0.37; 95% CI: 0.25 to 0.56; p < 0.001). The optimal IVUS MLA cutoff value for an FFR of ≤0.80 was 4.5 mm2 (77% sensitivity, 82% specificity, 84% positive predictive value, 75% negative predictive value, area under the curve: 0.83, 95% CI: 0.76 to 0.96; p < 0.001) overall and 4.1 to 4.5 mm2 in various subgroups. Adjustment for the body surface area, body mass index, and left ventricular mass did not improve the diagnostic accuracy of the IVUS MLA.ConclusionsIn patients with isolated ostial and shaft intermediate LMCA stenosis, an IVUS-derived MLA of ≤4.5 mm2 is a useful index of an FFR of ≤0.80.  相似文献   

17.
ObjectivesThis study aimed to investigate the characteristics of neoatherosclerosis (NA) in patients with diabetes mellitus (DM) after drug-eluting stent (DES) implantation using optical coherence tomography.BackgroundNA is an important substrate for stent failure. In vivo NA characteristics in DM patients have not been investigated.MethodsA total of 397 patients with 452 DES who underwent follow-up optical coherence tomography examination after DES implantation were enrolled. Characteristics of NA were compared between DM and non-DM patients. Neovascularization was defined as signal-poor holes or tubular structures with a diameter of 50 to 300 μm.ResultsA total of 123 DES with NA lesions in 115 patients were identified. The incidence of NA was similar between DM and non-DM patients (29.6% vs. 28.6%; p = 0.825). Compared with the non-DM group, neovascularization was more frequently observed in the DM group (55.1% vs. 32.4%; p = 0.012). The multivariate logistic model demonstrated that DM (odds ratio: 3.00; 95% confidence interval: 1.31 to 6.81; p = 0.009) and follow-up duration (odds ratio: 1.03; 95% confidence interval: 1.02 to 1.05; p < 0.001) were the independent predictors for neovascularization in NA lesions. DM patients with glycated hemoglobin ≥7.0% had a higher prevalence of thin-cap fibroatheroma compared with those with glycated hemoglobin <7.0% (40.0% vs. 8.3%; p = 0.01).ConclusionsThe incidence of NA was similar between patients with and without DM. Neovascularization in NA lesions was more frequent in those with DM. Poorly controlled DM patients had a higher incidence of thin-cap fibroatheroma, compared with those with well-controlled DM.  相似文献   

18.
ObjectivesThe purpose of this study was to compare the long-term clinical outcomes of patients with chronic total occlusion (CTO) and well-developed collateral circulation treated with revascularization versus medical therapy.BackgroundLittle is known about the clinical outcomes and optimal treatment strategies of CTO with well-developed collateral circulation.MethodsWe screened 2,024 consecutive patients with at least 1 CTO detected on coronary angiogram. Of these, we analyzed data from 738 patients with Rentrop 3 grade collateral circulation who were treated with medical therapy alone (n = 236), coronary artery bypass grafting (n = 170) or percutaneous coronary intervention (n = 332; 80.1% successful). Patients who underwent revascularization and medical therapy (revascularization group, n = 502) were compared with those who underwent medical therapy alone (medication group, n = 236) in terms of cardiac death and major adverse cardiac events (MACE), defined as the composite of cardiac death, myocardial infarction, and repeat revascularization.ResultsDuring a median follow-up duration of 42 months, multivariate analysis revealed a significantly lower incidence of cardiac death (hazard ratio [HR]: 0.29; 95% confidence interval [CI]: 0.15 to 0.58; p < 0.01) and MACE (HR: 0.32; 95% CI: 0.21 to 0.49; p < 0.01) in the revascularization group compared with the medication group. After propensity score matching, the incidence of cardiac death (HR: 0.27; 95% CI: 0.09 to 0.80; p = 0.02) and MACE (HR: 0.44; 95% CI: 0.23 to 0.82; p = 0.01) were still significantly lower in the revascularization group than in the medication group.ConclusionsIn patients with coronary CTO and well-developed collateral circulation, aggressive revascularization may reduce the risk of cardiac mortality and MACE.  相似文献   

19.
ObjectivesThis study sought to evaluate whether the permanent fluoropolymer-coated Xience Xpedition everolimus-eluting stent (Xience-EES) exhibits lower acute thrombogenicity compared with contemporary drug-eluting stents (DES) with biodegradable polymer coatings in an acute swine shunt model.BackgroundPrevious pre-clinical and clinical experience suggests that several factors may influence the predisposition for acute thrombus formation of polymer-coated DES, including stent design and the polymer coating technology. It remains unclear whether relevant differences exist with respect to acute thrombogenicity, particularly between current commercial stent designs using permanent polymers and those using biodegradable polymers.MethodsAn ex vivo carotid to jugular arteriovenous porcine shunt model involving a test circuit of 3 in-line stents, was used to test acute thrombogenicity, where Xience-EES (n = 24) was compared with 4 CE-marked DES with biodegradable polymer coatings (BioMatrix Flex, Synergy, Nobori, and Orsiro [n = 6 each]). After 1 h of circulation, platelet aggregation in whole mount stents was evaluated by confocal microscopy with immunofluorescent staining against dual platelet markers (CD61/CD42b) along with scanning electron microscopy.ResultsXience-EES showed the least percentage of thrombus-occupied area as compared with the biodegradable polymer-coated DES, with a significant difference compared with BioMatrix Flex and Synergy (mean differences: [BioMatrix Flex: 15.54, 95% confidence interval [CI]: 11.34 to 19.75, p < 0.001; Synergy: 8.64, 95% CI: 4.43 to 12.84, p < 0.001; Nobori: 4.22, 95% CI: -0.06 to 8.49, p = 0.055; Orsiro: 2.95, 95% CI: -1.26 to 7.15, p = 0.286). The number of cell nuclei on strut surfaces was also the least in Xience-EES, with a significant difference relative to BioMatrix Flex, Nobori, and Orsiro (mean ratios: BioMatrix Flex: 4.73, 95% CI: 2.46 to 9.08, p < 0.001; Synergy: 1.44, 95% CI: 0.75 to 2.76, p = 0.51; Nobori: 5.97, 95% CI: 3.11 to 11.44, p < 0.001; Orsiro: 5.16, 95% CI: 2.69 to 9.91, p < 0.001).ConclusionsXience-EES’s overall design confers acute thromboresistance relative to contemporary DES with biodegradable coatings, with less platelet aggregation versus BioMatrix Flex and Synergy, and less inflammatory cell attachment versus BioMatrix Flex, Nobori, and Orsiro, in an ex vivo swine shunt model, which lends support to reported clinical findings of lower early stent thrombosis.  相似文献   

20.
ObjectivesThe aim of this study was to examine the efficacy and bleeding outcomes of cangrelor in patients in the CHAMPION PHOENIX (A Clinical Trial Comparing Cangrelor to Clopidogrel Standard Therapy in Subjects Who Require Percutaneous Coronary Intervention [PCI]) who underwent percutaneous coronary intervention with bivalirudin.BackgroundCangrelor is a potent intravenous P2Y12 inhibitor with rapid onset and offset. In the CHAMPION PHOENIX, cangrelor compared with clopidogrel significantly reduced 48-h ischemic events including stent thrombosis, without increasing major bleeding. Bivalirudin has demonstrated ischemic outcomes similar to those with heparin plus glycoprotein IIb/IIIa inhibition, with reduced bleeding but increased early stent thrombosis.MethodsIn the modified intent-to-treat population, 2,059 patients (18.8%) received bivalirudin, with 1,014 patients in the cangrelor treatment arm and 1,045 in the clopidogrel treatment arm.ResultsAt 48 h, the primary endpoint of death, myocardial infarction, ischemia-driven revascularization, or stent thrombosis was lower with cangrelor versus clopidogrel (48 [4.7%] vs. 70 [6.7%]; odds ratio [OR]: 0.68, p = 0.047). Death was similar in both arms (2 [0.2%] vs. 2 [0.2%]). Myocardial infarction was reduced by cangrelor (37 [3.6%] vs. 59 [5.6%]; OR: 0.63, p = 0.03), as was death/myocardial infarction (39 [3.8%] vs. 61 [5.8%]; OR: 0.65, p = 0.04). Cangrelor was associated with a nonsignificant trend toward less stent thrombosis (7 [0.7%] vs. 15 [1.4%]; OR: 0.48, p = 0.10), which was evident within 2 h after percutaneous coronary intervention (p = 0.057). GUSTO (Global Use of Strategies to Open Occluded Arteries) severe bleeding was similar in both arms (2 of 1,021 [0.2%] vs. 2 of 1,055 [0.2%]) as were other bleeding definitions and transfusions. Efficacy and safety results were consistent in patients with stable angina, non–ST-segment elevation acute coronary syndrome, and ST-segment elevation myocardial infarction (p for interaction: 0.62 and 0.29).ConclusionsCangrelor may offer an attractive benefit risk profile when used in combination with bivalirudin.  相似文献   