首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
ObjectivesThe aim of the current study was to compare everolimus-eluting stents (EES) with sirolimus-eluting stents (SES) in patients undergoing primary angioplasty.BackgroundDrug-eluting stents may offer benefits in terms of repeat revascularization. However, as shown for first-generation drug-eluting stents, they may be counterbalanced by a potential higher risk of stent thrombosis, especially among patients with ST-segment elevation myocardial infarction (STEMI). No data have been reported so far on the long-term benefits and safety of the new generation of drug-eluting stents in STEMI.MethodsConsecutive STEMI patients admitted within 12 h of symptom onset and undergoing primary angioplasty and stent implantation at a tertiary center with 24-h primary percutaneous coronary intervention capability were randomly assigned to SES or EES. The primary endpoint was a major adverse cardiac event at 3-year follow-up. The secondary endpoints were death, reinfarction, definite or probable stent thrombosis, and target vessel revascularization at 3-year follow-up. No patient was lost to follow-up.ResultsFrom April 2007 to May 2009, 500 patients with STEMI were randomized to EES (n = 250) or SES (n = 250). No difference was observed in terms of baseline demographic and clinical characteristics between the groups. No difference was observed between the groups in terms of number of implanted stents per patient or total stent length. However, a larger reference diameter was observed with SES (3.35 ± 0.51 mm vs. 3.25 ± 0.51 mm, p = 0.001), whereas patients randomized to EES more often received glycoprotein IIb/IIIa inhibitors (54.4% vs. 42.4%, p = 0.006). Follow-up data were available in all patients (1,095 ± 159 days). No significant difference was observed between EES and SES in major adverse cardiac events (16% vs. 20.8%, adjusted hazard ratio [HR]: 0.75 [95% confidence interval (CI): 0.5 to 1.13], p = 0.17), cardiac death (4.4% vs. 5.6%, adjusted HR: 0.77 [95% CI: 0.35 to 1.71], p = 0.53), recurrent MI (6.4% vs. 10%, adjusted HR: 0.62 [95% CI: 0.33 to 1.16], p = 0.13), and target vessel revascularization (4.8% vs. 4.8%, adjusted HR: 1.00 [95% CI: 0.45 to 2.32], p = 0.99). However, EES was associated with a significant reduction in stent thrombosis (1.6% vs. 5.2%, adjusted HR: 0.3 [95% CI: 0.1 to 0.92], p = 0.035).ConclusionsThis study shows that among STEMI patients undergoing primary angioplasty, EES has similar efficacy as SES, but is associated with a significant reduction in stent thrombosis. (Randomized Comparison of Everolimus Eluting Stents and Sirolimus Eluting Stent in Patients With ST Elevation Myocardial Infarction [RACES-MI]; NCT01684982)  相似文献   

2.
ObjectivesThe purpose of this study was to compare the 2-year safety and effectiveness of new- versus early-generation drug-eluting stents (DES) according to the severity of coronary artery disease (CAD) as assessed by the SYNTAX (Synergy between Percutaneous Coronary Intervention with Taxus and Cardiac Surgery) score.BackgroundNew-generation DES are considered the standard-of-care in patients with CAD undergoing percutaneous coronary intervention. However, there are few data investigating the effects of new- over early-generation DES according to the anatomic complexity of CAD.MethodsPatient-level data from 4 contemporary, all-comers trials were pooled. The primary device-oriented clinical endpoint was the composite of cardiac death, myocardial infarction, or ischemia-driven target-lesion revascularization (TLR). The principal effectiveness and safety endpoints were TLR and definite stent thrombosis (ST), respectively. Adjusted hazard ratios (HRs) with 95% confidence intervals (CIs) were calculated at 2 years for overall comparisons, as well as stratified for patients with lower (SYNTAX score ≤11) and higher complexity (SYNTAX score >11).ResultsA total of 6,081 patients were included in the study. New-generation DES (n = 4,554) compared with early-generation DES (n = 1,527) reduced the primary endpoint (HR: 0.75 [95% CI: 0.63 to 0.89]; p = 0.001) without interaction (p = 0.219) between patients with lower (HR: 0.86 [95% CI: 0.64 to 1.16]; p = 0.322) versus higher CAD complexity (HR: 0.68 [95% CI: 0.54 to 0.85]; p = 0.001). In patients with SYNTAX score >11, new-generation DES significantly reduced TLR (HR: 0.36 [95% CI: 0.26 to 0.51]; p < 0.001) and definite ST (HR: 0.28 [95% CI: 0.15 to 0.55]; p < 0.001) to a greater extent than in the low-complexity group (TLR pint = 0.059; ST pint = 0.013). New-generation DES decreased the risk of cardiac mortality in patients with SYNTAX score >11 (HR: 0.45 [95% CI: 0.27 to 0.76]; p = 0.003) but not in patients with SYNTAX score ≤11 (pint = 0.042).ConclusionsNew-generation DES improve clinical outcomes compared with early-generation DES, with a greater safety and effectiveness in patients with SYNTAX score >11.  相似文献   

3.
ObjectivesThe purpose of this study was to compare the long-term clinical outcomes of patients with chronic total occlusion (CTO) and well-developed collateral circulation treated with revascularization versus medical therapy.BackgroundLittle is known about the clinical outcomes and optimal treatment strategies of CTO with well-developed collateral circulation.MethodsWe screened 2,024 consecutive patients with at least 1 CTO detected on coronary angiogram. Of these, we analyzed data from 738 patients with Rentrop 3 grade collateral circulation who were treated with medical therapy alone (n = 236), coronary artery bypass grafting (n = 170) or percutaneous coronary intervention (n = 332; 80.1% successful). Patients who underwent revascularization and medical therapy (revascularization group, n = 502) were compared with those who underwent medical therapy alone (medication group, n = 236) in terms of cardiac death and major adverse cardiac events (MACE), defined as the composite of cardiac death, myocardial infarction, and repeat revascularization.ResultsDuring a median follow-up duration of 42 months, multivariate analysis revealed a significantly lower incidence of cardiac death (hazard ratio [HR]: 0.29; 95% confidence interval [CI]: 0.15 to 0.58; p < 0.01) and MACE (HR: 0.32; 95% CI: 0.21 to 0.49; p < 0.01) in the revascularization group compared with the medication group. After propensity score matching, the incidence of cardiac death (HR: 0.27; 95% CI: 0.09 to 0.80; p = 0.02) and MACE (HR: 0.44; 95% CI: 0.23 to 0.82; p = 0.01) were still significantly lower in the revascularization group than in the medication group.ConclusionsIn patients with coronary CTO and well-developed collateral circulation, aggressive revascularization may reduce the risk of cardiac mortality and MACE.  相似文献   

4.
ObjectivesThis study sought to evaluate whether the permanent fluoropolymer-coated Xience Xpedition everolimus-eluting stent (Xience-EES) exhibits lower acute thrombogenicity compared with contemporary drug-eluting stents (DES) with biodegradable polymer coatings in an acute swine shunt model.BackgroundPrevious pre-clinical and clinical experience suggests that several factors may influence the predisposition for acute thrombus formation of polymer-coated DES, including stent design and the polymer coating technology. It remains unclear whether relevant differences exist with respect to acute thrombogenicity, particularly between current commercial stent designs using permanent polymers and those using biodegradable polymers.MethodsAn ex vivo carotid to jugular arteriovenous porcine shunt model involving a test circuit of 3 in-line stents, was used to test acute thrombogenicity, where Xience-EES (n = 24) was compared with 4 CE-marked DES with biodegradable polymer coatings (BioMatrix Flex, Synergy, Nobori, and Orsiro [n = 6 each]). After 1 h of circulation, platelet aggregation in whole mount stents was evaluated by confocal microscopy with immunofluorescent staining against dual platelet markers (CD61/CD42b) along with scanning electron microscopy.ResultsXience-EES showed the least percentage of thrombus-occupied area as compared with the biodegradable polymer-coated DES, with a significant difference compared with BioMatrix Flex and Synergy (mean differences: [BioMatrix Flex: 15.54, 95% confidence interval [CI]: 11.34 to 19.75, p < 0.001; Synergy: 8.64, 95% CI: 4.43 to 12.84, p < 0.001; Nobori: 4.22, 95% CI: -0.06 to 8.49, p = 0.055; Orsiro: 2.95, 95% CI: -1.26 to 7.15, p = 0.286). The number of cell nuclei on strut surfaces was also the least in Xience-EES, with a significant difference relative to BioMatrix Flex, Nobori, and Orsiro (mean ratios: BioMatrix Flex: 4.73, 95% CI: 2.46 to 9.08, p < 0.001; Synergy: 1.44, 95% CI: 0.75 to 2.76, p = 0.51; Nobori: 5.97, 95% CI: 3.11 to 11.44, p < 0.001; Orsiro: 5.16, 95% CI: 2.69 to 9.91, p < 0.001).ConclusionsXience-EES’s overall design confers acute thromboresistance relative to contemporary DES with biodegradable coatings, with less platelet aggregation versus BioMatrix Flex and Synergy, and less inflammatory cell attachment versus BioMatrix Flex, Nobori, and Orsiro, in an ex vivo swine shunt model, which lends support to reported clinical findings of lower early stent thrombosis.  相似文献   

5.
ObjectivesThe purpose of this study was to determine the efficacy and safety of radial versus femoral access in women undergoing coronary angiography/intervention.BackgroundThe risk of bleeding and vascular access site complications are higher in women than in men.MethodsIn a pre-specified RIVAL (RadIal Vs femorAL access for coronary intervention) subgroup analysis, we compared outcomes in women (n = 1,861) and men (n = 5,160) randomized to radial versus femoral access.ResultsOverall, women were at higher risk of major vascular complications compared with men (4.7% vs. 1.7%; p < 0.0001). Major vascular complications were significantly reduced with radial access in women (3.1% vs. 6.1%; hazard ratio [HR]: 0.5; 95% confidence interval [CI]: 0.32 to 0.78; p = 0.002) and in men (0.7% vs. 2.8%; HR: 0.27; 95% CI: 0.17 to 0.45; p < 0.0001; interaction p = 0.092). Crossover rates were higher with radial compared with femoral access in women (11.1% vs. 1.9%; HR: 5.88; p < 0.0001) and men (6.3% vs. 1.9%; HR: 3.32; p < 0.0001; interaction p = 0.054). Percutaneous coronary intervention (PCI) success rates were similar irrespective of access site (women: HR: 1.05; p = 0.471; men: HR: 1.00; p = 0.888; interaction p = 0.674), with no differences in PCI complications. In multivariable analyses, female sex was an independent predictor of major vascular complications (HR: 2.39; 95% CI: 1.76 to 3.25; p < 0.0001). There were consistent findings for women and men, with no difference for the primary composite endpoint of death, myocardial infarction, stroke, and non–coronary artery bypass grafting bleeding (women: 3.9% vs. 5.0%; HR: 0.77; 95% CI: 0.50 to 1.19; men: 3.54% vs. 3.5%; HR: 1.00; 95% CI: 0.75 to −1.34; interaction p = 0.325).ConclusionsWomen undergoing coronary angiography and PCI have a higher risk of vascular access site complications compared with men, and radial access is an effective method to reduce these complications.  相似文献   

6.
ObjectivesThis study sought to report the 5-year outcomes of everolimus-eluting stents (EES) and paclitaxel-eluting stents (PES) in an all-comers population undergoing percutaneous coronary intervention (PCI).BackgroundThe medium-term 1 and 2-year results of the prospective randomized COMPARE trial (A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice) showed superior clinical outcomes with EES compared with PES in an all-comers PCI population. Whether this benefit is sustained over longer-term follow-up is unknown. Furthermore, systematic long-term follow-up data on these metallic drug eluting stents with durable polymers are scarce.MethodsWe randomly assigned 1,800 patients undergoing PCI to EES or PES. The pre-specified composite primary endpoint was death, myocardial infarction (MI), or target vessel revascularization (TVR).ResultsFollow-up at 5 years was completed in 1,791 (99.5%) patients. Treatment with EES compared with PES led to a relative risk reduction of the primary endpoint by 27% (18.4% vs. 25.1%, p = 0.0005), driven by lower rates of MI (7.0% vs. 11.5%, p = 0.001) and TVR (7.4% vs. 11.4%, p = 0.003), but not with mortality (9.0% vs. 10.3%, relative risk 0.88, p = 0.36). Moreover, patients treated with EES compared with PES had lower rates of definite/probable stent thrombosis at 5 years (3.1% vs. 5.9%, p = 0.005). The hazard curves for TVR, MI, and stent thrombosis diverge over the first 3 years and, subsequently, progress in parallel.ConclusionsThe early- and medium-term superiority of EES over PES measured both by safety and efficacy endpoints is sustained at 5 years in this all-comer population. (A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice [COMPARE]; NCT01016041)  相似文献   

7.
ObjectivesThis study sought to evaluate the optimal percutaneous coronary intervention techniques using drug-eluting stents for bifurcation coronary lesions.BackgroundThe optimal bifurcation stenting technique needs to be evaluated.MethodsThe trial included 2 randomization studies separated by the presence of side branch (SB) stenosis for patients having non–left main bifurcation lesions. For 306 patients without SB stenosis, the routine final kissing balloon or leave-alone approaches were compared. Another randomization study compared the crush or single-stent approaches for 419 patients with SB stenosis.ResultsBetween the routine final kissing balloon and leave-alone groups for nondiseased SB lesions, angiographic restenosis occurred in 17.9% versus 9.3% (p = 0.064), comprising 15.1% versus 3.7% for the main branch (p = 0.004) and 2.8% versus 5.6% for the SB (p = 0.50) from 214 patients (69.9%) receiving 8-month angiographic follow-up. Incidence of major adverse cardiac events including death, myocardial infarction, or target vessel revascularization over 1 year was 14.0% versus 11.6% between the routine final kissing balloon and leave-alone groups (p = 0.57). In another randomization study for diseased SB lesions, 28.2% in the single-stent group received SB stents. From 300 patients (71.6%) receiving angiographic follow-up, between the crush and single-stent groups, angiographic restenosis rate was 8.4% versus 11.0% (p = 0.44), comprising 5.2% versus 4.8% for the main branch (p = 0.90) and 3.9% versus 8.3% for the SB (p = 0.12). One-year major adverse cardiac events rate between the crush and single-stent groups was 17.9% versus 18.5% (p = 0.84).ConclusionsAngiographic and clinical outcomes were excellent after percutaneous coronary intervention using drug-eluting stents with any stent technique for non–left main bifurcation lesions once the procedure was performed successfully.  相似文献   

8.
ObjectivesThe aim of this study was to investigate the correlation between in-stent neointimal tissue without features of neoatherosclerosis and long-term clinical outcomes.BackgroundRecent studies have reported differential morphological characteristics of in-stent neointimal tissue assessed by optical coherence tomography (OCT).MethodsThe study population consisted of 336 patients with 368 drug-eluting stent-treated lesions. Patients received a follow-up OCT examination without any intervention. OCT-based neointima was categorized as homogeneous (n = 227 lesions in 208 patients), heterogeneous (n = 79 lesions in 73 patients), or layered (n = 62 lesions in 55 patients). Major adverse cardiac events (MACE) (a composite of cardiac death, nonfatal myocardial infarction, or target lesion revascularization) were assessed according to neointimal patterns during long-term clinical follow-up after OCT examination.ResultsThe time interval between stent implantation and OCT examination was similar among the 3 groups (p = 0.64). On multivariate logistic regression analysis, the significant determinant for the heterogeneous neointima was age (odds ratio [OR]: 1.037, 95% confidence interval [CI]: 1.007 to 1.068, p = 0.015) and an initial clinical presentation of acute coronary syndrome (OR: 1.967, 95% CI: 1.159 to 3.339, p = 0.012). The overall median follow-up duration for all patients after follow-up OCT examination was 31.0 months, and this was statistically different among the heterogeneous group (22.0 months), the homogeneous group (34.0 months), and the layered group (28.0 months, overall p = 0.002). MACE occurred more frequently in patients with heterogeneous neointima over a median 31-month follow-up period after OCT examination (13.7% vs. 2.9% in homogeneous vs. 7.3% in layered, p = 0.001). A propensity score–adjusted Cox regression analysis showed that independent risk factors for MACE were inclusion in the heterogeneous neointima (hazard ratio: 3.925, 95% CI: 1.445 to 10.662, p = 0.007) and minimal lumen cross-sectional area (hazard ratio: 0.368, 95% CI: 0.242 to 0.560, p < 0.001).ConclusionsDetermination of neointimal characteristics is helpful in predicting long-term clinical outcomes. Our data suggest that heterogeneous lesions are linked to poor long-term clinical prognoses.  相似文献   

9.
ObjectivesThis study examined whether coronary angioscopy-verified in-stent yellow plaque at 1 year after drug-eluting stent (DES) implantation is associated with future event of very late stent failure (VLSF).BackgroundAtherosclerosis detected as yellow plaque by angioscopy has been associated with future events of acute coronary syndrome. Development of in-stent neoatherosclerosis is a probable mechanism of VLSF.MethodsThis study included 360 consecutive patients who received successful angioscopic examination at 1 year after implantation of a DES. They were clinically followed up for VLSF defined as cardiac death, acute myocardial infarction or unstable angina, or need for revascularization associated with the stent site.ResultsThe follow-up interval was 1,558 ± 890 days (4.3 ± 2.4 years). The incidence of VLSF was significantly higher in the patients with yellow plaque than in those without (8.1% vs. 1.6%; log rank p = 0.02). Multivariable analysis revealed the presence of yellow plaque (hazard ratio [HR]: 5.38; p = 0.02) and absence of statin therapy (HR: 3.25; p = 0.02) as risks of VLSF.ConclusionsIn-stent atherosclerosis evaluated by yellow plaque at 1 year after the implantation of DES and the absence of statin therapy were risks of VLSF. The underlying mechanism of VLSF appeared to be the progression of atherosclerosis as demonstrated by the yellow plaque.  相似文献   

10.
ObjectivesThis study sought to compare rates of stent thrombosis and major adverse cardiac and cerebrovascular events (MACCE) (composite of death, myocardial infarction, or stroke) after coronary stenting with drug-eluting stents (DES) versus bare-metal stents (BMS) in patients who participated in the DAPT (Dual Antiplatelet Therapy) study, an international multicenter randomized trial comparing 30 versus 12 months of dual antiplatelet therapy in subjects undergoing coronary stenting with either DES or BMS.BackgroundDespite antirestenotic efficacy of coronary DES compared with BMS, the relative risk of stent thrombosis and adverse cardiovascular events is unclear. Many clinicians perceive BMS to be associated with fewer adverse ischemic events and to require shorter-duration dual antiplatelet therapy than DES.MethodsProspective propensity-matched analysis of subjects enrolled into a randomized trial of dual antiplatelet therapy duration was performed. DES- and BMS-treated subjects were propensity-score matched in a many-to-one fashion. The study design was observational for all subjects 0 to 12 months following stenting. A subset of eligible subjects without major ischemic or bleeding events were randomized at 12 months to continued thienopyridine versus placebo; all subjects were followed through 33 months.ResultsAmong 10,026 propensity-matched subjects, DES-treated subjects (n = 8,308) had a lower rate of stent thrombosis through 33 months compared with BMS-treated subjects (n = 1,718, 1.7% vs. 2.6%; weighted risk difference −1.1%, p = 0.01) and a noninferior rate of MACCE (11.4% vs. 13.2%, respectively, weighted risk difference −1.8%, p = 0.053, noninferiority p < 0.001).ConclusionsDES-treated subjects have long-term rates of stent thrombosis that are lower than BMS-treated subjects. (The Dual Antiplatelet Therapy Study [DAPT study]; NCT00977938)  相似文献   

11.
ObjectivesThis study sought to assess the incidence and clinical impact of stent fracture (SF) after the PROMUS Element platinum-chromium everolimus-eluting stent (PtCr-EES).BackgroundSF remains an unresolved, clinically relevant issue, even in the newer-generation drug-eluting stent era.MethodsFrom March 2012 to August 2013, 816 patients with 1,094 lesions were treated only with PtCr-EES and 700 patients (85.7%) with 898 lesions undergoing follow-up angiography within 9 months after the index procedure were analyzed. SF was defined as complete or partial separation of the stent, as assessed by plain fluoroscopy, intravascular ultrasound, or optical coherence tomography during the follow-up. We assessed the rate of SF and the cumulative incidence of clinically driven target lesion revascularization and definite stent thrombosis within 9 months after the index procedure.ResultsSF was observed in 16 of 898 lesions (1.7%) and 16 of 700 patients (2.2%). Lesions with in-stent restenosis at baseline (odds ratio [OR]: 14.2, 95% confidence intervals [CI]: 5.09 to 39.7; p < 0.001) or hinge motion (OR: 4.31, 95% CI: 1.12 to 16.5; p = 0.03), and total stent length (per 10-mm increase; OR: 1.32, 95% CI: 1.12 to 1.57; p = 0.001) were predictors of SF. Cumulative incidence of clinically driven target lesion revascularization within 9-months was numerically higher in the SF group than that in the non-SF group (18.7% vs. 2.3%). Cumulative incidence of definite stent thrombosis within 9 months after the index procedure was similar between the SF and non-SF groups (0.0% vs. 0.23%).ConclusionsSF after PtCr-EES occurs in 1.7% of lesions and appears to be associated with clinically driven target lesion revascularization.  相似文献   

12.
ObjectivesThis study sought to determine whether there is an ideal level of platelet reactivity (PR) to optimize safety and efficacy within the large multicenter ADAPT-DES (Assessment of Dual AntiPlatelet Therapy With Drug-Eluting Stents) study of 8,582 patients receiving successful drug-eluting stent implantation.BackgroundPatients with high PR on clopidogrel have a greater incidence of adverse ischemic events after stent implantation, whereas low PR may increase bleeding. Due to limited sample size, previous studies have not been able to adjust for differences in baseline characteristics that may confound the relationship of PR and outcomes.MethodsIn the ADAPT-DES study, routine platelet function testing (VerifyNow) was performed following clopidogrel loading. To characterize the independent association between PR and clinical events, patients were stratified into quintiles of P2Y12 reaction units (PRU).ResultsThe PRU medians of the 5 quintiles were 57, 130, 187, 244, and 317 (most to least inhibited). There was a monotonic association between successively higher PRU quintiles and stent thrombosis, whereas for clinically relevant bleeding, the greatest risk occurred in the lowest PRU quintile, with similar risks across the 4 higher quintiles. These relationships remained significant in fully adjusted multivariable analyses (adjusted hazard ratio [HR] for stent thrombosis in Q5 versus Q1: 2.32; 95% confidence interval [CI]: 1.17 to 4.59; p = 0.02; adjusted HR for clinically relevant bleeding in Q5 versus Q1: 0.61; 95% CI: 0.47 to 0.77; p < 0.001). However, there were no significant independent associations between the level of PRU and mortality.ConclusionsIn this large observational study, increasing PRU was associated with a monotonic increase in stent thrombosis, whereas bleeding risk was confined to the lowest PRU quintile, suggesting an optimal therapeutic window of platelet inhibition at moderately inhibited PRU. However, there was no demonstrable threshold effect for PRU and mortality in adjusted analyses, perhaps due to the offsetting impact of bleeding and ischemia across the spectrum of platelet inhibition. (Assessment of Dual AntiPlatelet Therapy With Drug-Eluting Stents [ADAPT-DES]; NCT00638794)  相似文献   

13.
ObjectivesThis study investigated the impact of final kissing ballooning (FKB) after main vessel (MV) stenting on outcomes in patients with coronary bifurcation lesions after application of the 1-stent technique.BackgroundAlthough FKB has been established as the standard method for bifurcation lesions treated with a 2-stent strategy, its efficacy in a 1-stent approach is highly controversial.MethodsThis study enrolled 1,901 patients with a bifurcation lesion with a side branch diameter ≥2.3 mm, treated solely with the 1-stent technique using a drug-eluting stent from 18 centers in Korea between January 1, 2003 and December 31, 2009. The primary outcome was major adverse cardiac events (MACE)—cardiac death, myocardial infarction, or target lesion revascularization. Propensity score-matching analysis was also performed.ResultsFKB was performed in 620 patients and the post minimal lumen diameter of the MV and side branch was larger in the FKB group than in the non-FKB group. During follow-up (median 36 months), the incidence of MACE (adjusted hazard ratio [HR]: 0.68, 95% confidence interval [CI]: 0.46 to 0.99; p = 0.048) was lower in the FKB group than the non-FKB group. After propensity score matching (545 pairs), the FKB group had a lower incidence of MACE (adjusted HR: 0.50, 95% CI: 0.30 to 0.85; p = 0.01), and target lesion revascularization in the MV (adjusted HR: 0.51, 95% CI: 0.28 to 0.93; p = 0.03) and both vessels (adjusted HR: 0.47, 95% CI: 0.25 to 0.90; p = 0.02) than in the non-FKB group.ConclusionsIn coronary bifurcation lesions, we demonstrated that the 1-stent technique with FKB was associated with a favorable long-term clinical outcome, mainly driven by the reduction of target lesion revascularization in the MV or both vessels as a result of an increase in minimal lumen diameter. (Korean Coronary Bifurcation Stenting Registry II [COBIS II]: NCT01642992)  相似文献   

14.
ObjectivesThis study sought to compare the outcomes of spot stenting versus long stenting after intentional subintimal approach for long femoropopliteal chronic total occlusions (CTO).BackgroundThe optimal stenting strategy following the subintimal recanalization of long femoropopliteal chronic total occlusions has not been investigated.MethodsA total of 196 limbs in 163 patients, implanted with bare nitinol stents after subintimal approach in long femoropopliteal occlusions (lesion length 25 ± 8 cm), were retrospectively analyzed. The primary patency was compared between spot stenting (n = 129) and long stenting (n = 67).ResultsBaseline characteristics and immediate procedural results were similar between groups. Adjusted-primary patency (47% vs. 77%, p < 0.001) and adjusted-freedom from target lesion revascularization (52% vs. 84%, p < 0.001) at 2 years were significantly lower in the long stenting group than in the spot stenting group. The incidence of stent fracture, fracture type, and restenosis pattern did not differ between groups. Long stenting was an independent predictor of restenosis (hazard ratio [HR]: 2.0) along with other risk factors such as nonuse of clopidogrel (HR: 3.3) or cilostazol (HR: 2.2), small stent diameter (HR: 0.6), poor run-off (HR: 1.9), and post-procedural ankle-brachial index (HR: 0.1). Compared with spot stenting after adjustment using inverse probability of treatment weighting, long stenting, especially involving the P2 or P3 segment of the popliteal artery, was independently associated with 7.5-fold increases in restenosis risk (p < 0.001).ConclusionsThe primary patency was significantly higher with spot stenting than with long stenting following subintimal approach for long femoropopliteal chronic total occlusions. The risk of restenosis was especially higher when long stenting was extended to the distal popliteal artery.  相似文献   

15.
ObjectivesThe study sought to compare the risk of late outcome with a focus on very late definite stent thrombosis of the everolimus-eluting stent (EES) with that of the sirolimus-eluting stent (SES) at 3-year follow-up.BackgroundIn the SORT OUT IV (SORT OUT IV Trial), comparing the EES with the SES in patients with coronary artery disease, the EES was noninferior to the SES at 9 months. The SORT OUT IV trial provides long-term head-to-head randomized comparison of the EES with the SES.MethodsWe prospectively randomized 2,774 patients in the SORT OUT IV trial. Follow-up through 3 years was complete in 2,771 patients (99.9%). The 3-year pre-specified endpoints were composites of safety and efficacy (major adverse cardiac events [MACE]: cardiac death, myocardial infarction, target vessel revascularization, and definite stent thrombosis).ResultsAt 3 years, the composite endpoint MACE occurred in 9.8% of the EES group and in 11.1% of the SES group (hazard ratio [HR]: 0.89, 95% confidence interval [CI]: 0.70 to 1.12). Overall rate of definite stent thrombosis was lower in the EES group (0.2% vs. 1.4%; HR: 0.15, 95% CI: 0.04 to 0.50), which was largely attributable to a lower risk of very late definite stent thrombosis: 0.1% versus 0.8% (HR: 0.09, 95% CI: 0.01 to 0.70).ConclusionsAt 3-year follow-up, the MACE rate did not differ significantly between EES- and SES-treated patients. A significant reduction of overall and very late definite stent thrombosis was found in the EES group. (The SORT OUT IV TRIAL [SORT OUT IV]; NCT00552877).  相似文献   

16.
ObjectivesThe intention this PEPCAD-DES (Treatment of Drug-eluting Stent [DES] In-Stent Restenosis With SeQuent Please Paclitaxel Eluting Percutaneous Transluminal Coronary Angioplasty [PTCA] Catheter) study update was to demonstrate the safety and efficacy of paclitaxel-coated balloon (PCB) angioplasty in patients with DES-ISR at 3 years.BackgroundIn the PEPCAD-DES trial late lumen loss and the need for repeat target lesion revascularization (TLR) was significantly reduced with PCB angioplasty compared with plain old balloon angioplasty (POBA) in patients with drug-eluting stent in-stent restenosis (DES-ISR) at 6 months. We evaluated whether the clinical benefit of reduced TLR and major adverse cardiac events (MACE) was maintained up to 3 years.MethodsA total of 110 patients with DES-ISR in native coronary arteries with reference diameters ranging from 2.5 mm to 3.5 mm and lesion lengths ≤22 mm were randomized to treatment with either PCB or POBA in a multicenter, randomized, single-blind clinical study. With a 2:1 randomization, 72 patients were randomized to the PCB group and 38 patients to the POBA group. At baseline, there were lesions with at least 2 stent layers in PCB (52.8%, 38 of 72) and POBA (55.3%, 21 of 38) patients.ResultsAt 36 months, the TLR rates were significantly lower in the PCB group compared with the POBA control group (19.4% vs. 36.8%; p = 0.046). Multiple TLRs in individual patients were more frequent in the POBA group compared with the PCB group (more than 1 TLR: POBA, 13.2%; PCB, 1.4%; p = 0.021). The 36-month MACE rate was significantly reduced in the PCB group compared with the POBA group (20.8% vs. 52.6%, log-rank p = 0.001).ConclusionsPCB angioplasty was superior to POBA for the treatment of DES-ISR patients in terms of MACE and TLR for up to 36 months. There was no late catch-up phenomenon. (Treatment of Drug-eluting Stent [DES] In-Stent Restenosis With SeQuent® Please Paclitaxel Eluting Percutaneous Transluminal Coronary Angioplasty [PTCA] Catheter [PEPCAD-DES]; NCT00998439)  相似文献   

17.
ObjectivesThe aim of this study was to investigate the hypothesis that a novel biodegradable polymer–coated, cobalt-chromium (CoCr), sirolimus-eluting stent (BP-SES) is noninferior in safety and efficacy outcomes compared with a durable polymer (DP)-SES.BackgroundNo randomized trials have the compared safety and efficacy of BP-SES versus DP-SES on similar CoCr platforms, thereby isolating the effect of the polymer type.MethodsIn this prospective, single-blind, randomized trial conducted at 32 Chinese sites, 2,737 patients eligible for coronary stenting were treated with BP- or DP-SES in a 2:1 ratio. The primary endpoint was 12-month target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction, or clinically indicated target lesion revascularization. Secondary endpoints included TLF components, and definite/probable stent thrombosis.ResultsAt 12 months, the difference in the primary endpoint of TLF between BP-SES (6.3%) and DP-SES (6.1%) groups was 0.25% (95% confidence interval: −1.67% to 2.17%, p for noninferiority = 0.0002), demonstrating noninferiority of BP-SES to DP-SES. Individual TLF components of cardiac death (0.7% vs. 0.6%, p = 0.62), target vessel myocardial infarction (3.6% vs. 4.3%, p = 0.39), and clinically indicated target lesion revascularization (2.6% vs. 2.2%, p = 0.50) were similar, as were low definite/probable stent thrombosis rates (0.4% vs. 0.6%, p = 0.55).ConclusionsIn this large-scale real-world trial, BP-SES was noninferior to DP-SES for 1-year TLF. (Evaluate Safety and Effectiveness of the Tivoli ® DES and the Firebird ® DES for Treatment of Coronary Revascularization; NCT01681381)  相似文献   

18.
ObjectivesThe aim of this study was to determine the incidence, predictors, and outcomes of recurrent stent thrombosis (rST).BackgroundPatients who had an initial stent thrombosis (ST) develop may be at high risk of rST.MethodsWe analyzed a multicenter California registry of angiographic definite ST at 5 academic hospitals from 2005 to 2013. A detailed review of the angiogram and procedure was performed of patients with and without rST.ResultsAmong 221 patients with a median follow-up of 3.3 years, definite or probable rST developed in 29, including 19 with angiographic definite rST. The cumulative hazard ratio (HR) of definite or probable rST was 16% at 1 year and 24% at 5 years, whereas the cumulative HR of angiographic definite rST was 11% at 1 year and 20% at 5 years. Despite similar angiographic results, patients who had rST develop had significantly greater peak creatine kinase at the time of initial ST (mean, 2,655 mg/dl vs. 1,654 mg/dl; p = 0.05) than those without rST. The 3-year rate of major adverse cardiovascular events was 50% for patients with rST compared with 22% for patients with a single ST (p = 0.01). After multivariable adjustment, independent predictors of definite/probable rST were age (HR: 1.4; 95 confidence interval [CI]: 1.1 to 1.8 per 10 years), bifurcation ST (HR: 4.4; 95% CI: 1.8 to 10.9), and proximal vessel diameter (HR: 1.8; 95% CI: 1.1 to 3.2 per millimeter).ConclusionsrST represents an important cause of long-term morbidity and mortality after an initial ST. Bifurcation ST and a larger proximal reference vessel diameter are independently associated with an increased risk of rST.  相似文献   

19.
ObjectivesThis study sought to assess the frequency and clinical impact of dual antiplatelet therapy (DAPT) nonadherence.BackgroundThere are limited data on the impact of DAPT nonadherence during the first year after a second-generation drug-eluting stent placement.MethodsAfter successful Endeavor zotarolimus-eluting stent implantation, 2,265 patients were enrolled in a registry with limited exclusions and monitored during 12 months of prescribed DAPT. Predictors of any nonadherence (ANA) at 6 months were analyzed by multivariable analysis, and the association between ANA at 6 or 12 months with the endpoints of death, myocardial infarction, and stent thrombosis was assessed.ResultsThe study population included 30% female patients, 34% with diabetes and 36% with acute coronary syndromes. ANA occurred in 208 patients (9.6%) before 6 months and 378 patients (18.5%) before 1 year. Major bleeding (odds ratio [OR]: 12.83, 95% confidence interval [CI]: 7.55 to 21.80, p < 0.001) was the only predictor of ANA at 6 months. In time-dependent analyses, ANA before 6 months was associated with an increased risk of death or myocardial infarction (7.6% vs. 3.0%, p < 0.001) and a numerical increase in stent thrombosis (2.0% vs. 0.9%, p = 0.12). After adjustment for baseline differences, ANA within 6 months remained associated with death or MI (OR: 1.95, 95% CI: 1.02 to 3.75). ANA occurring after 6 months did not increase the risk of subsequent ischemic events.ConclusionsDAPT ANA occurs frequently and is associated with increased risk for thrombotic complications if it occurs within the first 6 months. Major bleeding was a significant correlate of DAPT ANA within 6 months. (EDUCATE: The MEDTRONIC Endeavor Drug Eluting Stenting: Understanding Care, Antiplatelet Agents and Thrombotic Events; NCT01069003)  相似文献   

20.
ObjectivesThis study aimed to investigate the clinical outcomes of patients presenting with recurrent drug-eluting stent (DES) in-stent restenosis (ISR) treated with a second-generation DES or with a drug-coated balloon (DCB).BackgroundTo date, there are no reports of DCB treatment and limited data with regard to the efficacy of further DES implantation for recurrent ISR.MethodsBetween January 2008 and December 2013, 171 lesions were assessed for eligibility (82 lesions in the second-generation DES group and 89 lesions in the DCB group).ResultsAcute gain was greater in the second-generation DES group (second-generation DES, 2.09 ± 0.53 mm vs. DCBs, 1.60 ± 0.62 mm, p < 0.001). The rates of major adverse cardiac events were comparable (at 1 year, DES 14.0% vs. DCBs 12.3%; at 2 years, DES 28.8% vs. DCBs 43.5%, p = 0.21). Major adverse cardiac event rates were mainly driven by target lesion revascularization (at 1 year, DES 12.5% vs. DCBs 10.9%; at 2 years, DES 27.7% vs. DCBs 38.3%; p = 0.40). Definite scaffold thrombosis occurred in 2 patients (1 patient in each group). Multivariable analysis revealed ISR recurrence within 1 year (hazard ratio: 2.43, 95% confidence interval: 1.14 to 5.18, p = 0.02) and lesion length (per 10-mm increase) (hazard ratio: 1.15, 95% confidence interval: 1.00 to 1.32, p = 0.049) to be independent predictors of TLR.ConclusionsThe results after both treatments were equivalent. ISR recurrence within 1 year of the first reintervention and lesion length were independent predictors of future target lesion revascularization. Larger studies are required to confirm the late (>1 year) differences with regard to clinical outcomes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号